Diagnostic Accuracy of Direct Immunofluorescence Test on Paraffin-Embedded Blocks in Comparison with Frozen Section Blocks in Renal Biopsies.
Int J Nephrol 2022;
2022:4974031. [PMID:
36226196 PMCID:
PMC9550505 DOI:
10.1155/2022/4974031]
[Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 08/07/2022] [Accepted: 09/12/2022] [Indexed: 01/10/2023] Open
Abstract
Background
In several published research, the evaluation of renal disorders using immunofluorescence on formalin-fixed, paraffin-embedded (FFPE) tissue sections versus immunofluorescence on frozen sections was compared. Each technique's accuracy varies greatly. This study's objective was to assess IF-P as a potential replacement for IF-F in the diagnosis of renal biopsy specimens.
Materials and Methods
To show immunoglobulin IgA, IgG, IgM, and C3 immune deposits, proteinase K digestion of paraffin-embedded renal biopsy was standardized and used in 51 renal biopsies. Sensitivity, specificity, false-positive, and false-negative values were calculated.
Results
IF-P showed a sensitivity of 93.1%, 76.9%, 63.6%, and 33.3%, and a specificity of 100%, 97.3%, 95%, and 100% for IgG, IgA, IgM, and C3, respectively. Compared to cases that had both routine IF and IF-P, 50 of 51 showed either the same amount of staining for the diagnostic immunoglobulin/complement or a small amount of difference. In most of the cases (49 of 51), diagnostic findings were found.
Conclusion
IF-P is a sensitive and precise approach for assessing immune deposits in renal tissue biopsies. We come to the conclusion that IF-P serves as a beneficial salvage immunohistochemistry method for renal biopsies that do not contain enough cortical tissue for IF-F.
Collapse