1
|
Grzeskowiak RM, Rifkin RE, Croy EG, Steiner RC, Seddighi R, Mulon PY, Adair HS, Anderson DE. Temporal Changes in Reverse Torque of Locking-Head Screws Used in the Locking Plate in Segmental Tibial Defect in Goat Model. Front Surg 2021; 8:637268. [PMID: 33987199 PMCID: PMC8111000 DOI: 10.3389/fsurg.2021.637268] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Accepted: 03/29/2021] [Indexed: 11/13/2022] Open
Abstract
The objective of this study was to evaluate changes in peak reverse torque (PRT) of the locking head screws that occur over time. A locking plate construct, consisting of an 8-hole locking plate and 8 locking screws, was used to stabilize a tibia segmental bone defect in a goat model. PRT was measured after periods of 3, 6, 9, and 12 months of ambulation. PRT for each screw was determined during plate removal. Statistical analysis revealed that after 6 months of loading, locking screws placed in position no. 4 had significantly less PRT as compared with screws placed in position no. 5 (p < 0.05). There were no statistically significant differences in PRT between groups as a factor of time (p > 0.05). Intracortical fractures occurred during the placement of 151 out of 664 screws (22.7%) and were significantly more common in the screw positions closest to the osteotomy (positions 4 and 5, p < 0.05). Periosteal and endosteal bone reactions and locking screw backout occurred significantly more often in the proximal bone segments (p < 0.05). Screw backout significantly, negatively influenced the PRT of the screws placed in positions no. 3, 4, and 5 (p < 0.05). The locking plate-screw constructs provided stable fixation of 2.5-cm segmental tibia defects in a goat animal model for up to 12 months.
Collapse
Affiliation(s)
- Remigiusz M Grzeskowiak
- Department of Large Animal Clinical Sciences, College of Veterinary Medicine, The University of Tennessee, Knoxville, Knoxville, TN, United States
| | - Rebecca E Rifkin
- Department of Large Animal Clinical Sciences, College of Veterinary Medicine, The University of Tennessee, Knoxville, Knoxville, TN, United States
| | - Elizabeth G Croy
- Department of Large Animal Clinical Sciences, College of Veterinary Medicine, The University of Tennessee, Knoxville, Knoxville, TN, United States
| | - Richard C Steiner
- Department of Large Animal Clinical Sciences, College of Veterinary Medicine, The University of Tennessee, Knoxville, Knoxville, TN, United States
| | - Reza Seddighi
- Department of Large Animal Clinical Sciences, College of Veterinary Medicine, The University of Tennessee, Knoxville, Knoxville, TN, United States
| | - Pierre-Yves Mulon
- Department of Large Animal Clinical Sciences, College of Veterinary Medicine, The University of Tennessee, Knoxville, Knoxville, TN, United States
| | - Henry S Adair
- Department of Large Animal Clinical Sciences, College of Veterinary Medicine, The University of Tennessee, Knoxville, Knoxville, TN, United States
| | - David E Anderson
- Department of Large Animal Clinical Sciences, College of Veterinary Medicine, The University of Tennessee, Knoxville, Knoxville, TN, United States
| |
Collapse
|
2
|
Grzeskowiak RM, Freeman LR, Harper DP, Anderson DE, Mulon P. Effect of cyclic loading on the stability of screws placed in the locking plates used to bridge segmental bone defects. J Orthop Res 2021; 39:516-524. [PMID: 32844515 PMCID: PMC7984344 DOI: 10.1002/jor.24838] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 08/04/2020] [Accepted: 08/18/2020] [Indexed: 02/04/2023]
Abstract
The objective of this study was to evaluate the ex vivo effect of cyclic loading on the stability of screws placed in locking plates used to bridge segmental bone defects. The primary interface stability was assessed using peak reverse torque. Eighteen, 8-hole stainless-steel 4.5 mm locking plates and 4.0-mm self-tapping locking-head screws were used to stabilize 40-mm segmental defects in goat tibiae. Treatment groups included control constructs without cyclic loading (n = 6) and constructs tested to 5000 (n = 6) and 10,000 cycles (n = 6) of 600 N compressive axial loading. The insertion of all screws was standardized to 400 N-cm insertion torque. Peak reverse torque was measured immediately after screw placement (control), or after the completion of the respective loading cycles. The difference between treatment groups was compared using univariate analysis of variance. The analysis revealed a significant difference in peak reverse torque of the screws among the treatment groups (p = .000). The mean reverse torque values equaled 343.5 ± 18.3 N-cm for non-cycled controls, 303.3 ± 25.9 and 296.0 ± 42.9 N-cm after 5000 and 10,000 cycles, respectively. Among all treatment groups, screws placed in the distal bone segment tended to have lesser peak reverse torque reduction than those placed in the proximal segment and the difference was proportional to the number of cycles (p = .562; p = .255; p = .013 in control, and after 5000 and 10,000 cycles, respectively). Cyclic loading may have a negative effect on the primary stability of screws placed in locking plate constructs used to bridge segmental bone defects and could contribute to the risk of screw loosening.
Collapse
Affiliation(s)
- Remigiusz M. Grzeskowiak
- Large Animal Clinical SciencesUniversity of Tennessee College of Veterinary MedicineKnoxvilleTennesseeUSA
| | - Laura R. Freeman
- Large Animal Clinical SciencesUniversity of Tennessee College of Veterinary MedicineKnoxvilleTennesseeUSA
| | - David P. Harper
- The Center for Renewable Carbon, Institute of AgricultureUniversity of TennesseeKnoxvilleTennesseeUSA
| | - David E. Anderson
- Large Animal Clinical SciencesUniversity of Tennessee College of Veterinary MedicineKnoxvilleTennesseeUSA
| | - Pierre‐Yves Mulon
- Large Animal Clinical SciencesUniversity of Tennessee College of Veterinary MedicineKnoxvilleTennesseeUSA
| |
Collapse
|
3
|
Grzeskowiak RM, Schumacher J, Dhar MS, Harper DP, Mulon PY, Anderson DE. Bone and Cartilage Interfaces With Orthopedic Implants: A Literature Review. Front Surg 2020; 7:601244. [PMID: 33409291 PMCID: PMC7779634 DOI: 10.3389/fsurg.2020.601244] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Accepted: 11/25/2020] [Indexed: 12/21/2022] Open
Abstract
The interface between a surgical implant and tissue consists of a complex and dynamic environment characterized by mechanical and biological interactions between the implant and surrounding tissue. The implantation process leads to injury which needs to heal over time and the rapidity of this process as well as the property of restored tissue impact directly the strength of the interface. Bleeding is the first and most relevant step of the healing process because blood provides growth factors and cellular material necessary for tissue repair. Integration of the implants placed in poorly vascularized tissue such as articular cartilage is, therefore, more challenging than compared with the implants placed in well-vascularized tissues such as bone. Bleeding is followed by the establishment of a provisional matrix that is gradually transformed into the native tissue. The ultimate goal of implantation is to obtain a complete integration between the implant and tissue resulting in long-term stability. The stability of the implant has been defined as primary (mechanical) and secondary (biological integration) stability. Successful integration of an implant within the tissue depends on both stabilities and is vital for short- and long-term surgical outcomes. Advances in research aim to improve implant integration resulting in enhanced implant and tissue interface. Numerous methods have been employed to improve the process of modifying both stability types. This review provides a comprehensive discussion of current knowledge regarding implant-tissue interfaces within bone and cartilage as well as novel approaches to strengthen the implant-tissue interface. Furthermore, it gives an insight into the current state-of-art biomechanical testing of the stability of the implants. Current knowledge reveals that the design of the implants closely mimicking the native structure is more likely to become well integrated. The literature provides however several other techniques such as coating with a bioactive compound that will stimulate the integration and successful outcome for the patient.
Collapse
Affiliation(s)
- Remigiusz M. Grzeskowiak
- Large Animal Clinical Sciences, University of Tennessee College of Veterinary Medicine, Knoxville, TN, United States
| | - Jim Schumacher
- Large Animal Clinical Sciences, University of Tennessee College of Veterinary Medicine, Knoxville, TN, United States
| | - Madhu S. Dhar
- Large Animal Clinical Sciences, University of Tennessee College of Veterinary Medicine, Knoxville, TN, United States
| | - David P. Harper
- The Center for Renewable Carbon, Institute of Agriculture, University of Tennessee, Knoxville, TN, United States
| | - Pierre-Yves Mulon
- Large Animal Clinical Sciences, University of Tennessee College of Veterinary Medicine, Knoxville, TN, United States
| | - David E. Anderson
- Large Animal Clinical Sciences, University of Tennessee College of Veterinary Medicine, Knoxville, TN, United States
| |
Collapse
|