1
|
Komasová S. Airport security as translation through division and movement. SOCIAL STUDIES OF SCIENCE 2022; 52:35-52. [PMID: 34524039 DOI: 10.1177/03063127211037733] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Based on an ethnographic research at Václav Havel Airport Prague, this article explores how contemporary airport security might by studied using an ANT-inspired approach. Security provision can be understood as a set of chains of translation that produces security and threat. Incoming actors, whose statuses are initially indeterminate, are translated into secure or threatening ones. This framing enables the uncovering of division and movement as the logics guide the system performance. The use of this perspective enables us to explicate the system's functioning in practice, including its inherent challenges and social consequences.
Collapse
|
2
|
Blažek P, O'Connor MJ, Weigand S, Grebmer C, Reif S, Fichtner S, Friedrich L, Reents T, Kottmaier M, Semmler V, Bourier F, Schunkert H, Deisenhofer I, Kolb C, Lennerz C. Security millimetre wave body scanner safe for patients with leadless pacemakers or subcutaneous implantable cardioverter-defibrillators. J Interv Card Electrophysiol 2020; 61:603-607. [PMID: 32860605 DOI: 10.1007/s10840-020-00830-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2020] [Accepted: 07/17/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE This study was designed to evaluate the electromagnetic interference (EMI) effects and safety of the new security screening millimetre wave body scanners (MWBSs) for patients with rare cardiac implantable electronic devices (CIEDs). METHODS We identified 73 patients with either entirely subcutaneous implantable cardioverter-defibrillators (S-ICD) or leadless pacemakers (LPM) attending routine device follow-up. CIED programming was optimised for the detection of EMI occurrence, and high-voltage therapy was disabled. Patients then underwent millimetre wave body scans under continuous ECG monitoring. Scanning was performed at the recommended distance as well as in close proximity to the scanner emulating accidental exposure. CIED function was observed for EMI effects. RESULTS There were no episodes of inhibition of pacing in the leadless pacemaker subgroup, no oversensing in the S-ICD subgroup and no spontaneous device reprogramming in any group. There was no change in pacing or sensing thresholds, and S-ICD vector eligibility remained unchanged after scanning with the MWBS. No CIEDs were identified by the MWBS during the study. CONCLUSION No EMI events were detected during the use of MWBSs by patients with either S-ICDs or LPMs. This data should be reassuring for patients suggesting that they can undergo security body scans without worries or disclosure of their CIED status.
Collapse
Affiliation(s)
- Patrick Blažek
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Klinik an der Technischen Universität München, Munich, Germany
| | | | - Severin Weigand
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Klinik an der Technischen Universität München, Munich, Germany.,DZHK (German Centre for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich, Germany
| | - Christian Grebmer
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Klinik an der Technischen Universität München, Munich, Germany
| | - Sebastian Reif
- Klinik für Kardiologie und Internistische Intensivmedizin, Klinikum Bogenhausen, Munich, Germany
| | - Stephanie Fichtner
- Klinikum Großhadern, Medizinische Klinik und Poliklinik I, Klinikum der Universität München, Munich, Germany
| | - Lena Friedrich
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Klinik an der Technischen Universität München, Munich, Germany
| | - Tilko Reents
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Klinik an der Technischen Universität München, Munich, Germany
| | - Marc Kottmaier
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Klinik an der Technischen Universität München, Munich, Germany
| | - Verena Semmler
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Klinik an der Technischen Universität München, Munich, Germany
| | - Felix Bourier
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Klinik an der Technischen Universität München, Munich, Germany
| | - Heribert Schunkert
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Klinik an der Technischen Universität München, Munich, Germany.,DZHK (German Centre for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich, Germany
| | - Isabel Deisenhofer
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Klinik an der Technischen Universität München, Munich, Germany
| | - Christof Kolb
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Klinik an der Technischen Universität München, Munich, Germany
| | - Carsten Lennerz
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Klinik an der Technischen Universität München, Munich, Germany. .,DZHK (German Centre for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich, Germany.
| |
Collapse
|
3
|
Lennerz C, O’Connor MJ, Blažek P, Weigand S, Grebmer C, Reif S, Friedrich L, Reents T, Bourier F, Schunkert H, Deisenhofer I, Kolb C. Modern Security Screening and Electromagnetic Interference With Cardiac Implantable Electronic Devices. J Am Coll Cardiol 2020; 75:1238-1239. [DOI: 10.1016/j.jacc.2020.01.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/17/2019] [Revised: 12/03/2019] [Accepted: 01/07/2020] [Indexed: 10/24/2022]
|
4
|
Napp A, Kolb C, Lennerz C, Bauer W, Schulz-Menger J, Kraus T, Marx N, Stunder D. Elektromagnetische Interferenz von aktiven Herzrhythmusimplantaten im Alltag und im beruflichen Umfeld. DER KARDIOLOGE 2019. [DOI: 10.1007/s12181-019-0335-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|