1
|
Yuan X, Kan X, Li J, Yan Y, Mirsadraee S, Mittal T, Shah A, Saunders D, Xu XY, Nienaber CA. Four-dimensional analysis of aortic root motion in normal population using retrospective multiphase computed tomography. EUROPEAN HEART JOURNAL. IMAGING METHODS AND PRACTICE 2024; 2:qyae007. [PMID: 39045205 PMCID: PMC11195731 DOI: 10.1093/ehjimp/qyae007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Accepted: 01/30/2024] [Indexed: 07/25/2024]
Abstract
Aims Aortic root motion is suspected to contribute to proximal aortic dissection. While motion of the aorta in four dimensions can be traced with real-time imaging, displacement and rotation in quantitative terms remain unknown. The hypothesis was to show feasibility of quantification of three-dimensional aortic root motion from dynamic CT imaging. Methods and results Dynamic CT images of 40 patients for coronary assessment were acquired using a dynamic protocol. Scans were ECG-triggered and segmented in 10 time-stepped phases (0-90%) per cardiac cycle. With identification of the sinotubular junction (STJ), a patient-specific co-ordinate system was created with the z-axis (out-of-plane) parallel to longitudinal direction. The left and right coronary ostia were traced at each time-step to quantify downward motion in reference to the STJ plane, motion within the STJ plane (in-plane), and the degree of rotation. Enrolled individuals had an age of 65 ± 12, and 14 were male (35%). The out-of-plane motion was recorded with the largest displacement of 10.26 ± 2.20 and 8.67 ± 1.69 mm referenced by left and right coronary ostia, respectively. The mean downward movement of aortic root was 9.13 ± 1.86 mm. The largest in-plane motion was recorded at 9.17 ± 2.33 mm and 6.51 ± 1.75 mm referenced by left and right coronary ostia, respectively. The largest STJ in-plane motion was 7.37 ± 1.96 mm, and rotation of the aortic root was 11.8 ± 4.60°. Conclusion In vivo spatial and temporal displacement of the aortic root can be identified and quantified from multiphase ECG-gated contrast-enhanced CT images. Knowledge of normal 4D motion of the aortic root may help understand its biomechanical impact in patients with aortopathy and pre- and post-surgical or transcatheter aortic valve replacement.
Collapse
Affiliation(s)
- Xun Yuan
- Cardiology and Aortic Centre, Royal Brompton & Harefield Hospitals, Guy’s and St Thomas’ NHS Foundation Trust, Sydney Street, London SW3 6NP, UK
- National Heart and Lung Institute, School of Medicine, Imperial College London, Exhibition Road, London SW7 2BX, UK
| | - Xiaoxin Kan
- Center for Vascular Surgery and Wound Care, Jinshan Hospital, Fudan University, Shanghai, China
- Department of Chemical Engineering, Imperial College London, London, UK
| | - Jianpeng Li
- Department of Cardiovascular Surgery, First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, China
| | - Yang Yan
- Department of Cardiovascular Surgery, First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, China
| | - Saeed Mirsadraee
- National Heart and Lung Institute, School of Medicine, Imperial College London, Exhibition Road, London SW7 2BX, UK
- Department of Radiology, Royal Brompton & Harefield Hospitals, Guy’s and St Thomas’ NHS Foundation Trust, London, UK
| | - Tarun Mittal
- National Heart and Lung Institute, School of Medicine, Imperial College London, Exhibition Road, London SW7 2BX, UK
- Department of Radiology, Royal Brompton & Harefield Hospitals, Guy’s and St Thomas’ NHS Foundation Trust, London, UK
| | - Andrew Shah
- Department of Radiology, East and North Hertfordshire NHS Foundation Trust, Middlesex, UK
| | - Debbie Saunders
- Department of Radiology, East and North Hertfordshire NHS Foundation Trust, Middlesex, UK
| | - Xiao Yun Xu
- Department of Chemical Engineering, Imperial College London, London, UK
| | - Christoph A Nienaber
- Cardiology and Aortic Centre, Royal Brompton & Harefield Hospitals, Guy’s and St Thomas’ NHS Foundation Trust, Sydney Street, London SW3 6NP, UK
- National Heart and Lung Institute, School of Medicine, Imperial College London, Exhibition Road, London SW7 2BX, UK
| |
Collapse
|
2
|
Qiao Y, Luo K, Fan J. Heat transfer mechanism in idealized healthy and diseased aortas using fluid-structure interaction method. Biomech Model Mechanobiol 2023; 22:1953-1964. [PMID: 37481471 DOI: 10.1007/s10237-023-01745-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2023] [Accepted: 07/06/2023] [Indexed: 07/24/2023]
Abstract
The heat transfer mechanism inside the human aorta may be related to the physiological function and lesion formation of the aortic wall. The objective of this study was to acquire the temperature distribution in the three-dimensional idealized aorta. An idealized healthy aortic geometry and three representative diseased aortas: aortic aneurysm, coarctation of the aorta, and aortic dissection were constructed. Advanced fluid-structure interaction (FSI) computational framework was applied to predict the aortic temperature distribution. The movement of the aortic root due to the heartbeat was also considered. The displacement distribution of the aortic vessel wall was consistent with clinical observation. The lesser curvature of the aortic arch, aneurysm body, coarctation region, and false lumen were all exposed to relatively high temperatures (over 310.006 K). We found that the rigid wall assumption slightly underestimated the magnitude of the whole aortic wall-averaged temperature while the changing trend and local temperature were like the results of the FSI method. Besides, the wall-averaged temperature would increase and the temperature inflection point would advance when the aortic vessel wall was loaded with a high heat flux. This pilot study revealed the aortic heat transfer mechanism and temperature distribution, and the findings may help to understand the physiological characteristics of the aortic vessel wall.
Collapse
Affiliation(s)
- Yonghui Qiao
- State Key Laboratory of Clean Energy Utilization, Zhejiang University, 38 Zheda Road, 310027, Hangzhou, China
| | - Kun Luo
- State Key Laboratory of Clean Energy Utilization, Zhejiang University, 38 Zheda Road, 310027, Hangzhou, China.
- Shanghai Institute for Advanced Study of Zhejiang University, Shanghai, China.
| | - Jianren Fan
- State Key Laboratory of Clean Energy Utilization, Zhejiang University, 38 Zheda Road, 310027, Hangzhou, China
- Shanghai Institute for Advanced Study of Zhejiang University, Shanghai, China
| |
Collapse
|
3
|
Parikh S, Moerman KM, Ramaekers MJFG, Schalla S, Bidar E, Delhaas T, Reesink K, Huberts W. Biomechanical Characterisation of Thoracic Ascending Aorta with Preserved Pre-Stresses. Bioengineering (Basel) 2023; 10:846. [PMID: 37508873 PMCID: PMC10376551 DOI: 10.3390/bioengineering10070846] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 07/07/2023] [Accepted: 07/11/2023] [Indexed: 07/30/2023] Open
Abstract
Mechanical properties of an aneurysmatic thoracic aorta are potential markers of future growth and remodelling and can help to estimate the risk of rupture. Aortic geometries obtained from routine medical imaging do not display wall stress distribution and mechanical properties. Mechanical properties for a given vessel may be determined from medical images at different physiological pressures using inverse finite element analysis. However, without considering pre-stresses, the estimation of mechanical properties will lack accuracy. In the present paper, we propose and evaluate a mechanical parameter identification technique, which recovers pre-stresses by determining the zero-pressure configuration of the aortic geometry. We first validated the method on a cylindrical geometry and subsequently applied it to a realistic aortic geometry. The verification of the assessed parameters was performed using synthetically generated reference data for both geometries. The method was able to estimate the true mechanical properties with an accuracy ranging from 98% to 99%.
Collapse
Affiliation(s)
- Shaiv Parikh
- Department of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University, 6229 ER Maastricht, The Netherlands
| | - Kevin M Moerman
- Department of Mechanical Engineering, University of Galway, H91 TK33 Galway, Ireland
| | - Mitch J F G Ramaekers
- Department of Cardiology, Heart & Vascular Centre, Maastricht University Medical Centre, 6229 HX Maastricht, The Netherlands
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre, 6229 HX Maastricht, The Netherlands
| | - Simon Schalla
- Department of Cardiology, Heart & Vascular Centre, Maastricht University Medical Centre, 6229 HX Maastricht, The Netherlands
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre, 6229 HX Maastricht, The Netherlands
| | - Elham Bidar
- Department of Cardiothoracic Surgery, Heart & Vascular Centre, Maastricht University Medical Centre, 6229 HX Maastricht, The Netherlands
| | - Tammo Delhaas
- Department of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University, 6229 ER Maastricht, The Netherlands
| | - Koen Reesink
- Department of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University, 6229 ER Maastricht, The Netherlands
| | - Wouter Huberts
- Department of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University, 6229 ER Maastricht, The Netherlands
- Department of Biomedical Engineering, Cardiovascular Biomechanics, Eindhoven University of Technology, 5612 AE Eindhoven, The Netherlands
| |
Collapse
|
4
|
Kim T, Tjahjadi NS, He X, van Herwaarden JA, Patel HJ, Burris NS, Figueroa CA. Three-Dimensional Characterization of Aortic Root Motion by Vascular Deformation Mapping. J Clin Med 2023; 12:4471. [PMID: 37445507 DOI: 10.3390/jcm12134471] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Revised: 06/29/2023] [Accepted: 07/02/2023] [Indexed: 07/15/2023] Open
Abstract
The aorta is in constant motion due to the combination of cyclic loading and unloading with its mechanical coupling to the contractile left ventricle (LV) myocardium. This aortic root motion has been proposed as a marker for aortic disease progression. Aortic root motion extraction techniques have been mostly based on 2D image analysis and have thus lacked a rigorous description of the different components of aortic root motion (e.g., axial versus in-plane). In this study, we utilized a novel technique termed vascular deformation mapping (VDM(D)) to extract 3D aortic root motion from dynamic computed tomography angiography images. Aortic root displacement (axial and in-plane), area ratio and distensibility, axial tilt, aortic rotation, and LV/Ao angles were extracted and compared for four different subject groups: non-aneurysmal, TAA, Marfan, and repair. The repair group showed smaller aortic root displacement, aortic rotation, and distensibility than the other groups. The repair group was also the only group that showed a larger relative in-plane displacement than relative axial displacement. The Marfan group showed the largest heterogeneity in aortic root displacement, distensibility, and age. The non-aneurysmal group showed a negative correlation between age and distensibility, consistent with previous studies. Our results revealed a strong positive correlation between LV/Ao angle and relative axial displacement and a strong negative correlation between LV/Ao angle and relative in-plane displacement. VDM(D)-derived 3D aortic root motion can be used in future studies to define improved boundary conditions for aortic wall stress analysis.
Collapse
Affiliation(s)
- Taeouk Kim
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
| | - Nic S Tjahjadi
- Department of Cardiac Surgery, University of Michigan, Ann Arbor, MI 48109, USA
| | - Xuehuan He
- Department of Radiology, University of Michigan, Ann Arbor, MI 48109, USA
| | - J A van Herwaarden
- Department of Vascular Surgery, University Medical Center Utrecht, 3584 CX Utrecht, The Netherlands
| | - Himanshu J Patel
- Department of Cardiac Surgery, University of Michigan, Ann Arbor, MI 48109, USA
| | - Nicholas S Burris
- Department of Radiology, University of Michigan, Ann Arbor, MI 48109, USA
| | - C Alberto Figueroa
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
- Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA
| |
Collapse
|
5
|
Hu H, Liu Z, Chen G, Yuan D, Zheng T. Analysis of aortic wall stress and morphology in patients with type B aortic dissection. MEDICINE IN NOVEL TECHNOLOGY AND DEVICES 2021. [DOI: 10.1016/j.medntd.2021.100081] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
6
|
Shirakawa T, Kuratani T, Yoshitatsu M, Shimamura K, Fukui S, Kurata A, Koyama Y, Toda K, Fukuda I, Sawa Y. Towards a Clinical Implementation of Measuring the Elastic Modulus of the Aorta from Cardiac Computed Tomography Images. IEEE Trans Biomed Eng 2021; 68:3543-3553. [PMID: 33945468 DOI: 10.1109/tbme.2021.3077362] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVE The elasticity of the aortic wall varies depending on age, vessel location, and the presence of aortic diseases. Noninvasive measurement will be a powerful tool to understand the mechanical state of the aorta in a living human body. This study aimed to determine the elastic modulus of the aorta using computed tomography images. METHODS We constructed our original formulae based on mechanics of materials. Then, we performed computed tomography scans of a silicon rubber tube by applying four pressure conditions to the lumen. The segment elastic modulus was calculated from the scanned images using our formulae. The actual modulus was measured using a tensile loading test for comparison. RESULTS The segment moduli of elasticity from the images were 0.525 [0.524, 0.527], 0.524 [0.520, 0.524], 0.520 [0.515, 0.523], and 0.522 [0.516, 0.532] (unit: MPa, median [25%, 75% quantiles]) for the four pressure conditions, respectively. The corresponding measurements in the tensile test were 0.548 [0.539, 0.566], 0.535 [0.528, 0.553], 0.526 [0.513, 0.543], and 0.523 [0.508, 0.530], respectively. These results indicated errors of 4.2%, 2.1%, 1.1%, and 0.2%, respectively. CONCLUSION Our formulae provided good estimations of the segment elastic moduli of a silicon rubber tube under physiological pressure conditions using the computed tomography images. SIGNIFICANCE In addition to the elasticity, the formulae provide the strain energy as well. These properties can be better predictors of aortic diseases. The formulae consist of clinical parameters commonly used in medical settings (pressure, diameter, and wall thickness).
Collapse
|
7
|
Karwat P, Klimonda Z, Styczyński G, Szmigielski C, Litniewski J. Aortic root movement correlation with the function of the left ventricle. Sci Rep 2021; 11:4473. [PMID: 33627700 PMCID: PMC7904934 DOI: 10.1038/s41598-021-83278-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Accepted: 02/01/2021] [Indexed: 12/12/2022] Open
Abstract
Echocardiographic assessment of systolic and diastolic function of the heart is often limited by image quality. However, the aortic root is well visualized in most patients. We hypothesize that the aortic root motion may correlate with the systolic and diastolic function of the left ventricle of the heart. Data obtained from 101 healthy volunteers (mean age 46.6 ± 12.4) was used in the study. The data contained sequences of standard two-dimensional (2D) echocardiographic B-mode (brightness mode, classical ultrasound grayscale presentation) images corresponding to single cardiac cycles. They also included sets of standard echocardiographic Doppler parameters of the left ventricular systolic and diastolic function. For each B-mode image sequence, the aortic root was tracked with use of a correlation tracking algorithm and systolic and diastolic values of traveled distances and velocities were determined. The aortic root motion parameters were correlated with the standard Doppler parameters used for the assessment of LV function. The aortic root diastolic distance (ARDD) mean value was 1.66 ± 0.26 cm and showed significant, moderate correlation (r up to 0.59, p < 0.0001) with selected left ventricular diastolic Doppler parameters. The aortic root maximal diastolic velocity (ARDV) was 10.8 ± 2.4 cm/s and also correlated (r up to 0.51, p < 0.0001) with some left ventricular diastolic Doppler parameters. The aortic root systolic distance (ARSD) was 1.63 ± 0.19 cm and showed no significant moderate correlation (all r values < 0.40). The aortic root maximal systolic velocity (ARSV) was 9.2 ± 1.6 cm/s and correlated in moderate range only with peak systolic velocity of medial mitral annulus (r = 0.44, p < 0.0001). Based on these results, we conclude, that in healthy subjects, aortic root motion parameters correlate significantly with established measurements of left ventricular function. Aortic root motion parameters can be especially useful in patients with low ultrasound image quality precluding usage of typical LV function parameters.
Collapse
Affiliation(s)
- Piotr Karwat
- Institute of Fundamental Technological Research, Polish Academy of Sciences, Pawińskiego 5B, 02-106, Warsaw, Poland.
| | - Ziemowit Klimonda
- Institute of Fundamental Technological Research, Polish Academy of Sciences, Pawińskiego 5B, 02-106, Warsaw, Poland
| | - Grzegorz Styczyński
- Department of Internal Medicine, Hypertension and Angiology, Medical University of Warsaw, Banacha 1A, 02-097, Warsaw, Poland
| | - Cezary Szmigielski
- Department of Internal Medicine, Hypertension and Angiology, Medical University of Warsaw, Banacha 1A, 02-097, Warsaw, Poland
| | - Jerzy Litniewski
- Institute of Fundamental Technological Research, Polish Academy of Sciences, Pawińskiego 5B, 02-106, Warsaw, Poland
| |
Collapse
|
8
|
Bouqentar MA, Sudres P, Wei W, Boufi M, Behr M, Evin M. Influence of the aortic morphological changes in aging on aortic flow. Comput Methods Biomech Biomed Engin 2019. [DOI: 10.1080/10255842.2020.1714965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Affiliation(s)
| | | | - W. Wei
- Aix-Marseille Univ, IFSTTAR, Marseille, France
| | | | - Michel Behr
- Aix-Marseille Univ, IFSTTAR, Marseille, France
| | - M. Evin
- Aix-Marseille Univ, IFSTTAR, Marseille, France
| |
Collapse
|