1
|
Li Z, Lu M, Zhang Y, Gong T, Wang J, Luo Y, Zhou Y, Chang Q, Lin J, Min L, Tu C. Reconstruction of the proximal radius with 3D-printed personalized prosthesis after tumor resection: case series. J Shoulder Elbow Surg 2024; 33:556-563. [PMID: 37783308 DOI: 10.1016/j.jse.2023.08.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/14/2023] [Revised: 08/27/2023] [Accepted: 08/31/2023] [Indexed: 10/04/2023]
Abstract
BACKGROUND Giant cell tumor of bone (GCTB) (Campanacci III) or malignant tumors extend to the epiphyseal region of the proximal radius, and intra-articular resection of the proximal radius is often needed. In the present study, we present the patients who underwent reconstruction of the proximal radius with 3D-printed personalized prosthesis after tumor resection, aiming to describe the prosthesis design and surgical technique and evaluate the clinical outcomes of this method. METHODS Between November 2018 and January 2021, 9 patients received radial hemiarthroplasty with 3D-printed personalized prostheses after tumor resection. The pathologic diagnosis was GCTB (Campanacci III) in 7 patients, osteosarcoma (IIB) in 1 patient, and synovial sarcoma (IIB) in 1 patient. The range of motion (ROM) and strength in terms of elbow flexion/extension and forearm supination/pronation were evaluated. Pain was assessed by the visual analog scale (VAS) preoperatively and at each follow-up visit. To evaluate the functional outcome, the Mayo Elbow Performance Score (MEPS) system and the Musculoskeletal Tumor Society (MSTS) scoring system were administered at each follow-up visit. Complications and oncological outcomes were recorded. RESULTS The patients were followed from 24 to 51 months, with a median follow-up of 35 months. No patients were lost to follow-up. During the follow-up, local recurrence and metastasis were not observed. The VAS score improved from a median of 5 points (range 4-7) preoperatively to 1 point (range 0-2) at the last follow-up visit. The mean MEPS score was 88.5% (83-93), and the mean MSTS score was 25.3 (24-27) at the last follow-up visit. No complications such as infection and aseptic loosening were detected. CONCLUSIONS The implantation of a 3D-printed personalized prosthesis after proximal radial resection showed excellent oncologic outcomes and postoperative function at short-term follow-up and is a viable alternative method for reconstruction of the proximal radius bone defect after tumor resection.
Collapse
Affiliation(s)
- Zhuangzhuang Li
- Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, Chengdu, China; Model Worker and Craftsman Talent Innovation Workshop of Sichuan Province, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Minxun Lu
- Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, Chengdu, China; Model Worker and Craftsman Talent Innovation Workshop of Sichuan Province, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Yuqi Zhang
- Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, Chengdu, China; Model Worker and Craftsman Talent Innovation Workshop of Sichuan Province, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Taojun Gong
- Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, Chengdu, China; Model Worker and Craftsman Talent Innovation Workshop of Sichuan Province, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Jie Wang
- Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, Chengdu, China; Model Worker and Craftsman Talent Innovation Workshop of Sichuan Province, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Yi Luo
- Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, Chengdu, China; Model Worker and Craftsman Talent Innovation Workshop of Sichuan Province, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Yong Zhou
- Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, Chengdu, China; Model Worker and Craftsman Talent Innovation Workshop of Sichuan Province, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Qing Chang
- Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, Chengdu, China; Model Worker and Craftsman Talent Innovation Workshop of Sichuan Province, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Jingqi Lin
- Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, Chengdu, China; Model Worker and Craftsman Talent Innovation Workshop of Sichuan Province, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Li Min
- Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, Chengdu, China; Model Worker and Craftsman Talent Innovation Workshop of Sichuan Province, West China Hospital, Sichuan University, Chengdu, Sichuan, China.
| | - Chongqi Tu
- Department of Orthopedics, Orthopaedic Research Institute, West China Hospital, Sichuan University, Chengdu, China; Model Worker and Craftsman Talent Innovation Workshop of Sichuan Province, West China Hospital, Sichuan University, Chengdu, Sichuan, China.
| |
Collapse
|
2
|
Yang Z, Niu N, Tang J, Wu L, He J, Shi J. Reconstruction of forearm support with ulnar translocation after resection of chondrosarcoma in the proximal radius. DER ORTHOPADE 2020; 49:1006-1012. [PMID: 32266431 DOI: 10.1007/s00132-020-03903-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
This is a report of the reconstructive surgery of a patient with chondrosarcoma in the proximal radius. After extensive resection of the proximal radius that contained the tumor, the skeleton of the forearm was reconstructed by ulnar translocation. This patient was followed for 2 years, no recurrence of the tumor was found and the function of the forearm was nearly normal. This case is reported and discussed and a literature review is presented.
Collapse
Affiliation(s)
- Zongqiang Yang
- General Hospital of Ningxia Medical University, 750004, Yinchuan, China
| | - Ningkui Niu
- General Hospital of Ningxia Medical University, 750004, Yinchuan, China
| | - Jing Tang
- General Hospital of Ningxia Medical University, 750004, Yinchuan, China
| | - Longyun Wu
- General Hospital of Ningxia Medical University, 750004, Yinchuan, China
| | - Jinwen He
- School of Clinical Medicine, Lanzhou University, 730030, Lanzhou, China
| | - Jiandang Shi
- General Hospital of Ningxia Medical University, 750004, Yinchuan, China.
| |
Collapse
|