1
|
Zhao Y, Olin RB, Hansen ESS, Laustsen C, Hanson LG, Ardenkjær-Larsen JH. 3D quantitative myocardial perfusion imaging with hyperpolarized HP001(bis-1,1-(hydroxymethyl)-[1- 13C]cyclopropane-d8): Application of gradient echo and balanced SSFP sequences. Magn Reson Med 2024. [PMID: 39344297 DOI: 10.1002/mrm.30320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Revised: 09/10/2024] [Accepted: 09/11/2024] [Indexed: 10/01/2024]
Abstract
PURPOSE This study aims to show the viability of conducting three-dimensional (3D) myocardial perfusion quantification covering the entire heart using both GRE and bSSFP sequences with hyperpolarized HP001. METHODS A GRE sequence and a bSSFP sequence, both with a stack-of-spirals readout, were designed and applied to three pigs. The images were reconstructed using 13 $$ {}^{13} $$ C coil sensitivity maps measured in a phantom experiment. Perfusion was quantified using a constrained decomposition method, and the estimated rest/stress perfusion values from 13 $$ {}^{13} $$ C GRE/bSSFP and Dynamic contrast-enhanced MRI (DCE-MRI) were individually analyzed through histograms and the mean perfusion values were compared with reference values obtained from PET( 15 $$ {}^{15} $$ O-water). The Myocardial Perfusion Reserve Index (MPRI) was estimated for 13 $$ {}^{13} $$ C GRE/bSSFP and DCE-MRI and compared with the reference values. RESULTS Perfusion values, estimated by both DCE and 13 $$ {}^{13} $$ C MRI, were found to be lower than reference values. However, DCE-MRI's estimated perfusion values were closer to the reference values than those obtained from 13 $$ {}^{13} $$ C MRI. In the case of MPRI estimation, the 13 $$ {}^{13} $$ C estimated MPRI values (GRE/bSSFP: 2.3/2.0) more closely align with the literature value (around 3) than the DCE estimated MPRI value (1.6). CONCLUSION This study demonstrated the feasibility of 3D whole-heart myocardial perfusion quantification using hyperpolarized HP001 with both GRE and bSSFP sequences. The 13 $$ {}^{13} $$ C perfusion measurements underestimated perfusion values compared to the 15 $$ {}^{15} $$ O PET literature value, while the 13 $$ {}^{13} $$ C estimated MPRI value aligned better with the literature. This preliminary result indicates 13 $$ {}^{13} $$ C imaging may more accurately estimate MPRI values compared to DCE-MRI.
Collapse
Affiliation(s)
- Yupeng Zhao
- Department of Health Technology, Technical University of Denmark, Kgs. Lyngby, Denmark
| | - Rie Beck Olin
- Department of Health Technology, Technical University of Denmark, Kgs. Lyngby, Denmark
| | | | | | - Lars G Hanson
- Department of Health Technology, Technical University of Denmark, Kgs. Lyngby, Denmark
- Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Hvidovre, Hvidovre, Denmark
| | | |
Collapse
|
2
|
Zhao Y, Lerche MH, Karlsson M, Olin RB, Hansen ESS, Aastrup M, Redda M, Laustsen C, Hanson LG, Ardenkjær-Larsen JH. Hyperpolarized Water for Coronary Artery Angiography and Whole-Heart Myocardial Perfusion Quantification. Tomography 2024; 10:1113-1122. [PMID: 39058056 PMCID: PMC11280581 DOI: 10.3390/tomography10070084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2024] [Revised: 07/09/2024] [Accepted: 07/10/2024] [Indexed: 07/28/2024] Open
Abstract
Purpose: Water freely diffuses across cell membranes, making it suitable for measuring absolute tissue perfusion. In this study, we introduce an imaging method for conducting coronary artery angiography and quantifying myocardial perfusion across the entire heart using hyperpolarized water. Methods:1H was hyperpolarized using dissolution dynamic nuclear polarization (dDNP) with UV-generated radicals. Submillimeter resolution coronary artery images were acquired as 2D projections using a spoiled GRE (SPGRE) sequence gated on diastole. Dynamic perfusion images were obtained with a multi-slice SPGRE with diastole gating, covering the entire heart. Perfusion values were analyzed through histograms, and the most frequent estimated perfusion value (the mode of the distribution), was compared with the average values for 15O water PET from the literature. Results: A liquid state polarization of 10% at the time of the injection and a 30 s T1 in D2O TRIS buffer were measured. Both coronary artery and dynamic perfusion images exhibited good quality. The main and small coronary artery branches were well resolved. The most frequent estimated perfusion value is around 0.6 mL/g/min, which is lower than the average values obtained from the literature for 15O-water PET (around 1.1 and 1.5 mL/g/min). Conclusions: The study successfully demonstrated the feasibility of achieving high-resolution, motion-free coronary artery angiography and 3D whole-heart quantitative myocardial perfusion using hyperpolarized water.
Collapse
Affiliation(s)
- Yupeng Zhao
- Department of Health Technology, Technical University of Denmark, DK-2800 Kgs. Lyngby, Denmark; (Y.Z.); (M.H.L.); (M.K.); (R.B.O.); (L.G.H.)
| | - Mathilde Hauge Lerche
- Department of Health Technology, Technical University of Denmark, DK-2800 Kgs. Lyngby, Denmark; (Y.Z.); (M.H.L.); (M.K.); (R.B.O.); (L.G.H.)
| | - Magnus Karlsson
- Department of Health Technology, Technical University of Denmark, DK-2800 Kgs. Lyngby, Denmark; (Y.Z.); (M.H.L.); (M.K.); (R.B.O.); (L.G.H.)
| | - Rie Beck Olin
- Department of Health Technology, Technical University of Denmark, DK-2800 Kgs. Lyngby, Denmark; (Y.Z.); (M.H.L.); (M.K.); (R.B.O.); (L.G.H.)
| | | | - Malene Aastrup
- MR Research Centre, Aarhus University, DK-8200 Aarhus, Denmark; (E.S.S.H.); (M.A.); (M.R.); (C.L.)
| | - Mohsen Redda
- MR Research Centre, Aarhus University, DK-8200 Aarhus, Denmark; (E.S.S.H.); (M.A.); (M.R.); (C.L.)
| | - Christoffer Laustsen
- MR Research Centre, Aarhus University, DK-8200 Aarhus, Denmark; (E.S.S.H.); (M.A.); (M.R.); (C.L.)
| | - Lars G. Hanson
- Department of Health Technology, Technical University of Denmark, DK-2800 Kgs. Lyngby, Denmark; (Y.Z.); (M.H.L.); (M.K.); (R.B.O.); (L.G.H.)
- Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Hvidovre, DK-2650 Hvidovre, Denmark
| | - Jan Henrik Ardenkjær-Larsen
- Department of Health Technology, Technical University of Denmark, DK-2800 Kgs. Lyngby, Denmark; (Y.Z.); (M.H.L.); (M.K.); (R.B.O.); (L.G.H.)
| |
Collapse
|
3
|
Chaumeil MM, Bankson JA, Brindle KM, Epstein S, Gallagher FA, Grashei M, Guglielmetti C, Kaggie JD, Keshari KR, Knecht S, Laustsen C, Schmidt AB, Vigneron D, Yen YF, Schilling F. New Horizons in Hyperpolarized 13C MRI. Mol Imaging Biol 2024; 26:222-232. [PMID: 38147265 PMCID: PMC10972948 DOI: 10.1007/s11307-023-01888-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 12/04/2023] [Accepted: 12/05/2023] [Indexed: 12/27/2023]
Abstract
Hyperpolarization techniques significantly enhance the sensitivity of magnetic resonance (MR) and thus present fascinating new directions for research and applications with in vivo MR imaging and spectroscopy (MRI/S). Hyperpolarized 13C MRI/S, in particular, enables real-time non-invasive assessment of metabolic processes and holds great promise for a diverse range of clinical applications spanning fields like oncology, neurology, and cardiology, with a potential for improving early diagnosis of disease, patient stratification, and therapy response assessment. Despite its potential, technical challenges remain for achieving clinical translation. This paper provides an overview of the discussions that took place at the international workshop "New Horizons in Hyperpolarized 13C MRI," in March 2023 at the Bavarian Academy of Sciences and Humanities, Munich, Germany. The workshop covered new developments, as well as future directions, in topics including polarization techniques (particularly focusing on parahydrogen-based methods), novel probes, considerations related to data acquisition and analysis, and emerging clinical applications in oncology and other fields.
Collapse
Affiliation(s)
- Myriam M Chaumeil
- Department of Physical Therapy and Rehabilitation Science, University of California, San Francisco, CA, USA.
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA.
| | - James A Bankson
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Kevin M Brindle
- Cancer Research UK Cambridge Institute, University of Cambridge, Cambridge, UK
- Department of Biochemistry, University of Cambridge, Cambridge, UK
| | | | - Ferdia A Gallagher
- Department of Radiology, Addenbrooke's Hospital, University of Cambridge, Cambridge, UK
- Cancer Research UK Cambridge Centre, Cambridge, UK
| | - Martin Grashei
- Department of Nuclear Medicine, TUM School of Medicine, Klinikum Rechts Der Isar, Technical University of Munich, Munich, Germany
| | - Caroline Guglielmetti
- Department of Physical Therapy and Rehabilitation Science, University of California, San Francisco, CA, USA
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - Joshua D Kaggie
- Department of Radiology, Addenbrooke's Hospital, University of Cambridge, Cambridge, UK
| | - Kayvan R Keshari
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York City, NY, USA
- Molecular Pharmacology Program, Memorial Sloan Kettering Cancer Center, New York City, NY, USA
- Weill Cornell Graduate School, New York City, NY, USA
| | | | - Christoffer Laustsen
- The MR Research Centre, Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 99, Aarhus, Denmark
| | - Andreas B Schmidt
- Partner Site Freiburg and German Cancer Research Center (DKFZ), German Cancer Consortium (DKTK), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Killianstr. 5a, 79106, Freiburg, Germany
- Department of Chemistry, Integrative Biosciences (Ibio), Karmanos Cancer Institute (KCI), Wayne State University, Detroit, MI, 48202, USA
| | - Daniel Vigneron
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - Yi-Fen Yen
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Franz Schilling
- Department of Nuclear Medicine, TUM School of Medicine, Klinikum Rechts Der Isar, Technical University of Munich, Munich, Germany
- Partner Site Freiburg and German Cancer Research Center (DKFZ), German Cancer Consortium (DKTK), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany
| |
Collapse
|
4
|
Patel AR, Kramer CM. Perfusion Imaging for the Heart. Magn Reson Imaging Clin N Am 2024; 32:125-134. [PMID: 38007275 DOI: 10.1016/j.mric.2023.09.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2023]
Abstract
The use of myocardial perfusion imaging during a stress cardiac magnetic resonance (CMR) examination for the evaluation of coronary artery disease is now recommended by both US and European guidelines. Several studies have demonstrated high diagnostic accuracy for the detection of hemodynamically significant coronary artery disease. Stress perfusion CMR has been shown to be a noninvasive and cost-effective alternative to guide coronary revascularization.
Collapse
Affiliation(s)
- Amit R Patel
- Department of Medicine, From the Cardiovascular Division, University of Virginia Health, 1215 Lee Street, Box 800158, Charlottesville, VA 22908, USA; Department of Radiology and Medical Imaging, From the Cardiovascular Division, University of Virginia Health, 1215 Lee Street, Box 800158, Charlottesville, VA 22908, USA.
| | - Christopher M Kramer
- Department of Medicine, From the Cardiovascular Division, University of Virginia Health, 1215 Lee Street, Box 800158, Charlottesville, VA 22908, USA; Department of Radiology and Medical Imaging, From the Cardiovascular Division, University of Virginia Health, 1215 Lee Street, Box 800158, Charlottesville, VA 22908, USA
| |
Collapse
|
5
|
Sun P, Wu Z, Lin L, Hu G, Zhang X, Wang J. MR-Nucleomics: The study of pathological cellular processes with multinuclear magnetic resonance spectroscopy and imaging in vivo. NMR IN BIOMEDICINE 2023; 36:e4845. [PMID: 36259659 DOI: 10.1002/nbm.4845] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 09/28/2022] [Accepted: 10/08/2022] [Indexed: 06/16/2023]
Abstract
Clinical medicine has experienced a rapid development in recent decades, during which therapies targeting specific cellular signaling pathways, or specific cell surface receptors, have been increasingly adopted. While these developments in clinical medicine call for improved precision in diagnosis and treatment monitoring, modern medical imaging methods are restricted mainly to anatomical imaging, lagging behind the requirements of precision medicine. Although positron emission tomography and single photon emission computed tomography have been used clinically for studies of metabolism, their applications have been limited by the exposure risk to ionizing radiation, the subsequent limitation in repeated and longitudinal studies, and the incapability in assessing downstream metabolism. Magnetic resonance spectroscopy (MRS) or spectroscopic imaging (MRSI) are, in theory, capable of assessing molecular activities in vivo, although they are often limited by sensitivity. Here, we review some recent developments in MRS and MRSI of multiple nuclei that have potential as molecular imaging tools in the clinic.
Collapse
Affiliation(s)
- Peng Sun
- Clinical & Technical Support, Philips Healthcare, China
| | - Zhigang Wu
- Clinical & Technical Support, Philips Healthcare, China
| | - Liangjie Lin
- Clinical & Technical Support, Philips Healthcare, China
| | - Geli Hu
- Clinical & Technical Support, Philips Healthcare, China
| | | | - Jiazheng Wang
- Clinical & Technical Support, Philips Healthcare, China
| |
Collapse
|
6
|
Fuetterer M, Traechtler J, Busch J, Peereboom SM, Dounas A, Manka R, Weisskopf M, Cesarovic N, Stoeck CT, Kozerke S. Hyperpolarized Metabolic and Parametric CMR Imaging of Longitudinal Metabolic-Structural Changes in Experimental Chronic Infarction. JACC Cardiovasc Imaging 2022; 15:2051-2064. [PMID: 36481073 DOI: 10.1016/j.jcmg.2022.08.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 08/10/2022] [Accepted: 08/24/2022] [Indexed: 11/17/2022]
Abstract
BACKGROUND Prolonged ischemia and myocardial infarction are followed by a series of dynamic processes that determine the fate of the affected myocardium toward recovery or necrosis. Metabolic adaptions are considered to play a vital role in the recovery of salvageable myocardium in the context of stunned and hibernating myocardium. OBJECTIVES The potential of hyperpolarized pyruvate cardiac magnetic resonance (CMR) alongside functional and parametric CMR as a tool to study the complex metabolic-structural interplay in a longitudinal study of chronic myocardial infarction in an experimental pig model is investigated. METHODS Metabolic imaging using hyperpolarized [1-13C] pyruvate and proton-based CMR including cine, T1/T2 relaxometry, dynamic contrast-enhanced, and late gadolinium enhanced imaging were performed on clinical 3.0-T and 1.5-T MR systems before infarction and at 6 days and 5 and 9 weeks postinfarction in a longitudinal study design. Chronic myocardial infarction in pigs was induced using catheter-based occlusion and compared with healthy controls. RESULTS Metabolic image data revealed temporarily elevated lactate-to-bicarbonate ratios at day 6 in the infarcted relative to remote myocardium. The temporal changes of lactate-to-bicarbonate ratios were found to correlate with changes in T2 and impaired local contractility. Assessment of pyruvate dehydrogenase flux via the hyperpolarized [13C] bicarbonate signal revealed recovery of aerobic cellular respiration in the hibernating myocardium, which correlated with recovery of local radial strain. CONCLUSIONS This study demonstrates the potential of hyperpolarized CMR to longitudinally detect metabolic changes after cardiac infarction over days to weeks. Viable myocardium in the area at risk was identified based on restored pyruvate dehydrogenase flux.
Collapse
Affiliation(s)
- Maximilian Fuetterer
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Julia Traechtler
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Julia Busch
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | | | - Andreas Dounas
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Robert Manka
- Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland
| | - Miriam Weisskopf
- Division of Surgical Research, University Hospital Zurich, Zurich, Switzerland
| | - Nikola Cesarovic
- Division of Surgical Research, University Hospital Zurich, Zurich, Switzerland; Institute of Translational Cardiovascular Technologies, ETH Zurich, Zurich, Switzerland
| | - Christian Torben Stoeck
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland; Division of Surgical Research, University Hospital Zurich, Zurich, Switzerland
| | - Sebastian Kozerke
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland.
| |
Collapse
|
7
|
In Vivo Magnetic Resonance Spectroscopy Methods for Investigating Cardiac Metabolism. Metabolites 2022; 12:metabo12020189. [PMID: 35208262 PMCID: PMC8877606 DOI: 10.3390/metabo12020189] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 02/14/2022] [Accepted: 02/15/2022] [Indexed: 11/17/2022] Open
Abstract
Magnetic resonance spectroscopy (MRS) is a non-invasive and non-ionizing technique, enabling in vivo investigation of cardiac metabolism in normal and diseased hearts. In vivo measurement tools are critical for studying mechanisms that regulate cardiac energy metabolism in disease developments and to assist in early response assessments to novel therapies. For cardiac MRS, proton (1H), phosphorus (31P), and hyperpolarized 13-carbon (13C) provide valuable metabolic information for diagnosis and treatment assessment purposes. Currently, low sensitivity and some technical limitations limit the utility of MRS. An essential step in translating MRS for clinical use involves further technological improvements, particularly in coil design, improving the signal-to-noise ratios, field homogeneity, and optimizing radiofrequency sequences. This review addresses the recent advances in metabolic imaging by MRS from primarily the literature published since 2015.
Collapse
|
8
|
Abouelnour A, Gori T. Vasomotor Dysfunction in Patients with Ischemia and Non-Obstructive Coronary Artery Disease: Current Diagnostic and Therapeutic Strategies. Biomedicines 2021; 9:biomedicines9121774. [PMID: 34944590 PMCID: PMC8698648 DOI: 10.3390/biomedicines9121774] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Revised: 11/15/2021] [Accepted: 11/23/2021] [Indexed: 11/16/2022] Open
Abstract
Many patients who present with symptoms or objective evidence of ischemia have no or non-physiologically-significant disease on invasive coronary angiography. The diagnosis of ischemic heart disease is thus often dismissed, and patients receive false reassurance or other diagnoses are pursued. We now know that a significant proportion of these patients have coronary microvascular dysfunction and/or vasospastic disease as the underlying pathophysiology of their clinical presentation. Making the correct diagnosis of such abnormalities is important not only because they impact the quality of life, with recurring symptoms and unnecessary repeated testing, but also because they increase the risk for adverse cardiovascular events. The mainstay of diagnosis remains an invasive comprehensive physiologic assessment, which further allows stratifying these patients into appropriate “endotypes”. It has been shown that tailoring treatment to the patient’s assigned endotype improves symptoms and quality of life. In addition to the conventional drugs used in chronic stable angina, multiple newer agents are being investigated. Moreover, innovative non-pharmacologic and interventional therapies are emerging to provide a bail-out in refractory cases. Many of these novel therapies fail to show consistent benefits, but others show quite promising results.
Collapse
Affiliation(s)
- Amr Abouelnour
- Zentrum für Kardiologie, Kardiologie I, und Deutsches Zentrum für Herz und Kreislauf Forschung, University Medical Center Mainz, 55131 Standort Rhein-Main, Germany;
- Cardiovascular Institute, Assiut University, Assiut 71515, Egypt
| | - Tommaso Gori
- Zentrum für Kardiologie, Kardiologie I, und Deutsches Zentrum für Herz und Kreislauf Forschung, University Medical Center Mainz, 55131 Standort Rhein-Main, Germany;
- Correspondence:
| |
Collapse
|
9
|
Bøgh N, Olin RB, Hansen ESS, Gordon JW, Bech SK, Bertelsen LB, Sánchez-Heredia JD, Blicher JU, Østergaard L, Ardenkjær-Larsen JH, Bok RA, Vigneron DB, Laustsen C. Metabolic MRI with hyperpolarized [1- 13C]pyruvate separates benign oligemia from infarcting penumbra in porcine stroke. J Cereb Blood Flow Metab 2021; 41:2916-2927. [PMID: 34013807 PMCID: PMC8756460 DOI: 10.1177/0271678x211018317] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 04/15/2021] [Accepted: 04/19/2021] [Indexed: 01/17/2023]
Abstract
Acute ischemic stroke patients benefit from reperfusion in a short time-window after debut. Later treatment may be indicated if viable brain tissue is demonstrated and this outweighs the inherent risks of late reperfusion. Magnetic resonance imaging (MRI) with hyperpolarized [1-13C]pyruvate is an emerging technology that directly images metabolism. Here, we investigated its potential to detect viable tissue in ischemic stroke. Stroke was induced in pigs by intracerebral injection of endothelin 1. During ischemia, the rate constant of pyruvate-to-lactate conversion, kPL, was 52% larger in penumbra and 85% larger in the infarct compared to the contralateral hemisphere (P = 0.0001). Within the penumbra, the kPL was 50% higher in the regions that later infarcted compared to non-progressing regions (P = 0.026). After reperfusion, measures of pyruvate-to-lactate conversion were slightly decreased in the infarct compared to contralateral. In addition to metabolic imaging, we used hyperpolarized pyruvate for perfusion-weighted imaging. This was consistent with conventional imaging for assessment of infarct size and blood flow. Lastly, we confirmed the translatability of simultaneous assessment of metabolism and perfusion with hyperpolarized MRI in healthy volunteers. In conclusion, hyperpolarized [1-13C]pyruvate may aid penumbral characterization and increase access to reperfusion therapy for late presenting patients.
Collapse
Affiliation(s)
- Nikolaj Bøgh
- The MR Research Center, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Rie B Olin
- Department of Health Technology, Technical University of Denmark, Kongens Lyngby, Denmark
| | - Esben SS Hansen
- The MR Research Center, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Jeremy W Gordon
- Department of Radiology and Biomedical Imaging, University of California San Francisco, CA, USA
| | - Sabrina K Bech
- The MR Research Center, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Lotte B Bertelsen
- The MR Research Center, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Juan D Sánchez-Heredia
- Department of Health Technology, Technical University of Denmark, Kongens Lyngby, Denmark
| | - Jakob U Blicher
- Department of Neurology, Aarhus University Hospital, Aarhus, Denmark
- Center of Functionally Integrative Neuroscience, Aarhus University, Aarhus, Denmark
| | - Leif Østergaard
- Center of Functionally Integrative Neuroscience, Aarhus University, Aarhus, Denmark
| | - Jan H Ardenkjær-Larsen
- Department of Health Technology, Technical University of Denmark, Kongens Lyngby, Denmark
- GE Healthcare, Brøndby, Denmark
| | - Robert A Bok
- Department of Radiology and Biomedical Imaging, University of California San Francisco, CA, USA
| | - Daniel B Vigneron
- Department of Radiology and Biomedical Imaging, University of California San Francisco, CA, USA
- UC Berkeley-UCSF Graduate Program in Bioengineering, University of California San Francisco and University of California, Berkeley, CA, USA
| | - Christoffer Laustsen
- The MR Research Center, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| |
Collapse
|
10
|
Wen Y, Qi H, Østergaard Mariager C, Mose Nielsen P, Bonde Bertelsen L, Stødkilde-Jørgensen H, Laustsen C. Sex Differences in Kidney Function and Metabolism Assessed Using Hyperpolarized [1- 13C]Pyruvate Interleaved Spectroscopy and Nonspecific Imaging. ACTA ACUST UNITED AC 2021; 6:5-13. [PMID: 32280745 PMCID: PMC7138520 DOI: 10.18383/j.tom.2020.00022] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Metabolic sex differences have recently been shown to be particularly important in tailoring treatment strategies. Sex has a major effect on fat turnover rates and plasma lipid delivery in the body. Differences in kidney structure and transporters between male and female animals have been found. Here we investigated sex-specific renal pyruvate metabolic flux and whole-kidney functional status in age-matched healthy Wistar rats. Blood oxygenation level–dependent and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) were used to assess functional status. Hyperpolarized [1-13C]pyruvate was used to assess the metabolic differences between male and female rats. Female rats had a 41% ± 3% and 41% ± 5% lower absolute body and kidney weight, respectively, than age-matched male rats. No difference was seen between age-matched male and female rats in the kidney-to-body weight ratio. A 56% ± 11% lower lactate production per mL/100 mL/min was found in female rats than in age-matched male rats measured by hyperpolarized magnetic resonance and DCE MRI. Female rats had a 33% ± 11% higher glomerular filtration rate than age-matched male rats measured by DCE MRI. A similar renal oxygen tension (T2*) was found between age-matched male and female rats as shown by blood oxygenation level–dependent MRI. The results were largely independent of the pyruvate volume and the difference in body weight. This study shows an existing metabolic difference between kidneys in age-matched male and female rats, which indicates that sex differences need to be considered when performing animal experiments.
Collapse
Affiliation(s)
- Yibo Wen
- MR Research Centre, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; and.,The First Affiliated Hospital of Zhengzhou University, Zhengzhou University, Henan, China
| | - Haiyun Qi
- MR Research Centre, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; and
| | | | - Per Mose Nielsen
- MR Research Centre, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; and
| | - Lotte Bonde Bertelsen
- MR Research Centre, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; and
| | | | - Christoffer Laustsen
- MR Research Centre, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; and
| |
Collapse
|
11
|
Traechtler J, Vishnevskiy V, Fuetterer M, Kozerke S. Joint image and field map estimation for multi-echo hyperpolarized 13 C metabolic imaging of the heart. Magn Reson Med 2021; 86:258-276. [PMID: 33660300 DOI: 10.1002/mrm.28710] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Revised: 01/13/2021] [Accepted: 01/14/2021] [Indexed: 12/21/2022]
Abstract
PURPOSE Image reconstruction of metabolic images from hyperpolarized 13 C multi-echo data acquisition is sensitive to susceptibility-induced phase offsets, which are particularly challenging in the heart. A model-based framework for joint estimation of metabolite images and field map from echo shift-encoded data is proposed. Using simulations, it is demonstrated that correction of signal spilling due to incorrect decomposition of metabolites and geometrical distortions over a wide range of off-resonance gradients is possible. In vivo feasibility is illustrated using hyperpolarized [1-13 C]pyruvate in the pig heart. METHODS The model-based reconstruction for multi-echo, multicoil data was implemented as a nonconvex minimization problem jointly optimizing for metabolic images and B0 . A comprehensive simulation framework for echo shift-encoded hyperpolarized [1-13 C]pyruvate imaging was developed and applied to assess reconstruction performance and distortion correction of the proposed method. In vivo data were obtained in four pigs using hyperpolarized [1-13 C]pyruvate on a clinical 3T MR system with a six-channel receiver coil. Dynamic images were acquired during suspended ventilation using cardiac-triggered multi-echo single-shot echo-planar imaging in short-axis orientation. RESULTS Simulations revealed that off-resonance gradients up to ±0.26 ppm/pixel can be corrected for with reduced signal spilling and geometrical distortions yielding an accuracy of ≥90% in terms of Dice similarity index. In vivo, improved geometrical consistency (10% Dice improvement) compared to image reconstruction without field map correction and with reference to anatomical data was achieved. CONCLUSION Joint image and field map estimation allows addressing off-resonance-induced geometrical distortions and metabolite spilling in hyperpolarized 13 C metabolic imaging of the heart.
Collapse
Affiliation(s)
- Julia Traechtler
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Valery Vishnevskiy
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Maximilian Fuetterer
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Sebastian Kozerke
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| |
Collapse
|
12
|
Zhang Q, Dai X, Zhang H, Zeng Y, Luo K, Li W. Recent advances in development of nanomedicines for multiple sclerosis diagnosis. Biomed Mater 2021; 16:024101. [PMID: 33472182 DOI: 10.1088/1748-605x/abddf4] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Multiple sclerosis (MS) is a neurodegenerative disease with a high morbidity and disease burden. It is characterized by the loss of the myelin sheath, resulting in the disruption of neuron electrical signal transmissions and sensory and motor ability deficits. The diagnosis of MS is crucial to its management, but the diagnostic sensitivity and specificity are always a challenge. To overcome this challenge, nanomedicines have recently been employed to aid the diagnosis of MS with an improved diagnostic efficacy. Advances in nanomedicine-based contrast agents in magnetic resonance imaging scanning of MS lesions, and nanomedicine-derived sensors for detecting biomarkers in the cerebrospinal fluid biopsy, or analyzing the composition of exhaled breath gas, have demonstrated the potential of using nanomedicines in the accurate diagnosis of MS. This review aims to provide an overview of recent advances in the application of nanomedicines for the diagnosis of MS and concludes with perspectives of using nanomedicines for the development of safe and effective MS diagnostic nanotools.
Collapse
Affiliation(s)
- Qin Zhang
- Department of Radiology, Department of Postgraduate Students, and Department of Respiratory and Critical Care Medicine, West China Hospital, Sichuan University, Chengdu 610041, People's Republic of China. West China School of Medicine, Sichuan University, Chengdu 610041, People's Republic of China. These authors contributed equally to this work
| | | | | | | | | | | |
Collapse
|
13
|
Mariager CØ, Hansen ESS, Bech SK, Eiskjaer H, Nielsen PF, Ringgaard S, Kimose HH, Laustsen C. Development of a human heart-sized perfusion system for metabolic imaging studies using hyperpolarized [1- 13 C]pyruvate MRI. Magn Reson Med 2020; 85:3510-3521. [PMID: 33368597 DOI: 10.1002/mrm.28639] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Revised: 11/09/2020] [Accepted: 11/19/2020] [Indexed: 11/09/2022]
Abstract
PURPOSE Increasing worldwide demand for cardiac transplantation has spurred new developments to increase the donor pool. Normothermic preservation of heart grafts for transplantation is an emerging strategy to improve the utilization of marginal grafts. Hyperpolarized MR using metabolic tracers such as [1-13 C]pyruvate, provide a novel means of investigating metabolic status without the use of ionizing radiation. We demonstrate the use of this methodology to examine ex vivo perfused porcine heart grafts. METHODS Hearts from three 40-kg Danish domestic pigs were harvested and subsequently perfused in Langendorff mode under normothermic conditions, using an MR-compatible perfusion system adapted to the heart. Proton MRI and hyperpolarized [1-13 C]pyruvate were used to investigate and quantify the functional and metabolic status of the grafts. RESULTS Hearts were perfused with whole blood for 120 min, using a dynamic contrast-enhanced perfusion experiment to verify successful myocardial perfusion. Hyperpolarized [1-13 C]pyruvate MRI was used to assess the metabolic state of the myocardium. Functional assessment was performed using CINE imaging and ventricular pressure data. High lactate and modest alanine levels were observed in the hyperpolarized experiment. The functional assessment produced reduced functional parameters. This suggests an altered functional and metabolic profile compared with corresponding in vivo values. CONCLUSION We investigated the metabolic and functional status of machine-perfused porcine hearts. Utilizing hyperpolarized methodology to acquire detailed myocardial metabolic information-in combination with already established MR methods for cardiac investigation-provides a powerful tool to aid the progress of donor heart preservation.
Collapse
Affiliation(s)
| | | | - Sabrina Kahina Bech
- Department of Clinical Medicine, MR Research Centre, Aarhus University, Aarhus, Denmark
| | - Hans Eiskjaer
- Department of Clinical Medicine, Department of Cardiology, Aarhus University Hospital, Aarhus, Denmark
| | - Peter Fast Nielsen
- Department of Cardiothoracic Surgery, Aarhus University Hospital, Aarhus, Denmark
| | - Steffen Ringgaard
- Department of Clinical Medicine, MR Research Centre, Aarhus University, Aarhus, Denmark
| | - Hans-Henrik Kimose
- Department of Cardiothoracic Surgery, Aarhus University Hospital, Aarhus, Denmark
| | - Christoffer Laustsen
- Department of Clinical Medicine, MR Research Centre, Aarhus University, Aarhus, Denmark
| |
Collapse
|
14
|
Manning WJ. Journal of Cardiovascular Magnetic Resonance: 2017/2018 in review. J Cardiovasc Magn Reson 2019; 21:79. [PMID: 31884956 PMCID: PMC6936125 DOI: 10.1186/s12968-019-0594-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Accepted: 12/17/2019] [Indexed: 12/14/2022] Open
Abstract
There were 89 articles published in the Journal of Cardiovascular Magnetic Resonance (JCMR) in 2017, including 76 original research papers, 4 reviews, 5 technical notes, 1 guideline, and 3 corrections. The volume was down slightly from 2017 with a corresponding 15% decrease in manuscript submissions from 405 to 346 and thus reflects a slight increase in the acceptance rate from 25 to 26%. The decrease in submissions for the year followed the initiation of the increased author processing charge (APC) for Society for Cardiovascular Magnetic Resonance (SCMR) members for manuscripts submitted after June 30, 2018. The quality of the submissions continues to be high. The 2018 JCMR Impact Factor (which is published in June 2019) was slightly lower at 5.1 (vs. 5.46 for 2017; as published in June 2018. The 2018 impact factor means that on average, each JCMR published in 2016 and 2017 was cited 5.1 times in 2018. Our 5 year impact factor was 5.82.In accordance with Open-Access publishing guidelines of BMC, the JCMR articles are published on-line in a continuus fashion in the chronologic order of acceptance, with no collating of the articles into sections or special thematic issues. For this reason, over the years, the Editors have felt that it is useful for the JCMR audience to annually summarize the publications into broad areas of interest or themes, so that readers can view areas of interest in a single article in relation to each other and contemporaneous JCMR publications. In this publication, the manuscripts are presented in broad themes and set in context with related literature and previously published JCMR papers to guide continuity of thought within the journal. In addition, as in the past two years, I have used this publication to also convey information regarding the editorial process and as a "State of our JCMR."This is the 12th year of JCMR as an open-access publication with BMC (formerly known as Biomed Central). The timing of the JCMR transition to the open access platform was "ahead of the curve" and a tribute to the vision of Dr. Matthias Friedrich, the SCMR Publications Committee Chair and Dr. Dudley Pennell, the JCMR editor-in-chief at the time. The open-access system has dramatically increased the reading and citation of JCMR publications and I hope that you, our authors, will continue to send your very best, high quality manuscripts to JCMR for consideration. It takes a village to run a journal and I thank our very dedicated Associate Editors, Guest Editors, Reviewers for their efforts to ensure that the review process occurs in a timely and responsible manner. These efforts have allowed the JCMR to continue as the premier journal of our field. This entire process would also not be possible without the dedication and efforts of our managing editor, Diana Gethers. Finally, I thank you for entrusting me with the editorship of the JCMR as I begin my 4th year as your editor-in-chief. It has been a tremendous experience for me and the opportunity to review manuscripts that reflect the best in our field remains a great joy and highlight of my week!
Collapse
Affiliation(s)
- Warren J Manning
- Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
| |
Collapse
|
15
|
Mariager CO, Lindhardt J, Nielsen PM, Schulte RF, Ringgaard S, Laustsen C. Fractional Perfusion: A Simple Semi-Parametric Measure for Hyperpolarized 13C MR. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2019. [DOI: 10.1109/trpms.2019.2905724] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|