1
|
Huang HH, Hargrove LJ, Ortiz-Catalan M, Sensinger JW. Integrating Upper-Limb Prostheses with the Human Body: Technology Advances, Readiness, and Roles in Human-Prosthesis Interaction. Annu Rev Biomed Eng 2024; 26:503-528. [PMID: 38594922 DOI: 10.1146/annurev-bioeng-110222-095816] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/11/2024]
Abstract
Significant advances in bionic prosthetics have occurred in the past two decades. The field's rapid expansion has yielded many exciting technologies that can enhance the physical, functional, and cognitive integration of a prosthetic limb with a human. We review advances in the engineering of prosthetic devices and their interfaces with the human nervous system, as well as various surgical techniques for altering human neuromusculoskeletal systems for seamless human-prosthesis integration. We discuss significant advancements in research and clinical translation, focusing on upper limbprosthetics since they heavily rely on user intent for daily operation, although many discussed technologies have been extended to lower limb prostheses as well. In addition, our review emphasizes the roles of advanced prosthetics technologies in complex interactions with humans and the technology readiness levels (TRLs) of individual research advances. Finally, we discuss current gaps and controversies in the field and point out future research directions, guided by TRLs.
Collapse
Affiliation(s)
- He Helen Huang
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
- Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, North Carolina, USA;
| | - Levi J Hargrove
- Department of Physical Medicine and Rehabilitation, Northwestern University, Chicago, Illinois, USA
- Center for Bionic Medicine, Shirley Ryan AbilityLab, Chicago, Illinois, USA
| | - Max Ortiz-Catalan
- Medical Bionics Department, University of Melbourne, Melbourne, Australia
- Bionics Institute, Melbourne, Australia
| | - Jonathon W Sensinger
- Institute of Biomedical Engineering, University of New Brunswick, Fredericton, New Brunswick, Canada;
| |
Collapse
|
2
|
Xie A, Li C, Chou CH, Li T, Dai C, Lan N. A hybrid sensory feedback system for thermal nociceptive warning and protection in prosthetic hand. Front Neurosci 2024; 18:1351348. [PMID: 38650624 PMCID: PMC11033464 DOI: 10.3389/fnins.2024.1351348] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Accepted: 03/25/2024] [Indexed: 04/25/2024] Open
Abstract
Background Advanced prosthetic hands may embed nanosensors and microelectronics in their cosmetic skin. Heat influx may cause damage to these delicate structures. Protecting the integrity of the prosthetic hand becomes critical and necessary to ensure sustainable function. This study aims to mimic the sensorimotor control strategy of the human hand in perceiving nociceptive stimuli and triggering self-protective mechanisms and to investigate how similar neuromorphic mechanisms implemented in prosthetic hand can allow amputees to both volitionally release a hot object upon a nociceptive warning and achieve reinforced release via a bionic withdrawal reflex. Methods A steady-state temperature prediction algorithm was proposed to shorten the long response time of a thermosensitive temperature sensor. A hybrid sensory strategy for transmitting force and a nociceptive temperature warning using transcutaneous electrical nerve stimulation based on evoked tactile sensations was designed to reconstruct the nociceptive sensory loop for amputees. A bionic withdrawal reflex using neuromorphic muscle control technology was used so that the prosthetic hand reflexively opened when a harmful temperature was detected. Four able-bodied subjects and two forearm amputees randomly grasped a tube at the different temperatures based on these strategies. Results The average prediction error of temperature prediction algorithm was 8.30 ± 6.00%. The average success rate of six subjects in perceiving force and nociceptive temperature warnings was 86.90 and 94.30%, respectively. Under the reinforcement control mode in Test 2, the median reaction time of all subjects was 1.39 s, which was significantly faster than the median reaction time of 1.93 s in Test 1, in which two able-bodied subjects and two amputees participated. Results demonstrated the effectiveness of the integration of nociceptive sensory strategy and withdrawal reflex control strategy in a closed loop and also showed that amputees restored the warning of nociceptive sensation while also being able to withdraw from thermal danger through both voluntary and reflexive protection. Conclusion This study demonstrated that it is feasible to restore the sensorimotor ability of amputees to warn and react against thermal nociceptive stimuli. Results further showed that the voluntary release and withdrawal reflex can work together to reinforce heat protection. Nevertheless, fusing voluntary and reflex functions for prosthetic performance in activities of daily living awaits a more cogent strategy in sensorimotor control.
Collapse
Affiliation(s)
- Anran Xie
- Laboratory of NeuroRehabilitation Engineering, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Chen Li
- Laboratory of NeuroRehabilitation Engineering, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Chih-hong Chou
- Laboratory of NeuroRehabilitation Engineering, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Institute of Medical Robotics, School of Biomedical Engineering Shanghai Jiao Tong University, Shanghai, China
| | - Tie Li
- i-Lab, Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO), Chinese Academy of Sciences (CAS), Suzhou, China
| | - Chenyun Dai
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Ning Lan
- Laboratory of NeuroRehabilitation Engineering, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Institute of Medical Robotics, School of Biomedical Engineering Shanghai Jiao Tong University, Shanghai, China
- Richard and Loan Hill Department of Biomedical Engineering, University of Illinois Chicago, Chicago, IL, United States
| |
Collapse
|
3
|
Tchimino J, Dideriksen JL, Dosen S. EMG feedback improves grasping of compliant objects using a myoelectric prosthesis. J Neuroeng Rehabil 2023; 20:119. [PMID: 37705008 PMCID: PMC10500847 DOI: 10.1186/s12984-023-01237-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Accepted: 08/24/2023] [Indexed: 09/15/2023] Open
Abstract
BACKGROUND Closing the control loop in myoelectric prostheses by providing artificial somatosensory feedback is recognized as an important goal. However, designing a feedback interface that is effective in realistic conditions is still a challenge. Namely, in some situations, feedback can be redundant, as the information it provides can be readily obtained through hearing or vision (e.g., grasping force estimated from the deformation of a compliant object). EMG feedback is a non-invasive method wherein the tactile stimulation conveys to the user the level of their own myoelectric signal, hence a measurement intrinsic to the interface, which cannot be accessed incidentally. METHODS The present study investigated the efficacy of EMG feedback in prosthesis force control when 10 able-bodied participants and a person with transradial amputation used a myoelectric prosthesis to grasp compliant objects of different stiffness values. The performance with feedback was compared to that achieved when the participants relied solely on incidental cues. RESULTS The main outcome measures were the task success rate and completion time. EMG feedback resulted in significantly higher success rates regardless of pin stiffness, indicating that the feedback enhanced the accuracy of force application despite the abundance of incidental cues. Contrary to expectations, there was no difference in the completion time between the two feedback conditions. Additionally, the data revealed that the participants could produce smoother control signals when they received EMG feedback as well as more consistent commands across trials, signifying better control of the system by the participants. CONCLUSIONS The results presented in this study further support the efficacy of EMG feedback when closing the prosthesis control loop by demonstrating its benefits in particularly challenging conditions which maximized the utility of intrinsic feedback sources.
Collapse
Affiliation(s)
- Jack Tchimino
- Neurorehabilitation Systems, Department of Health Science and Technology, Aalborg University, Aalborg, Denmark
| | - Jakob Lund Dideriksen
- Neurorehabilitation Systems, Department of Health Science and Technology, Aalborg University, Aalborg, Denmark
| | - Strahinja Dosen
- Neurorehabilitation Systems, Department of Health Science and Technology, Aalborg University, Aalborg, Denmark.
| |
Collapse
|
4
|
Mayer RM, Mohammadi A, Tan Y, Alici G, Choong P, Oetomo D. Temporal and spatial characteristics of bone conduction as non-invasive haptic sensory feedback for upper-limb prosthesis. Front Neurosci 2023; 17:1113009. [PMID: 37056306 PMCID: PMC10086128 DOI: 10.3389/fnins.2023.1113009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Accepted: 02/24/2023] [Indexed: 03/30/2023] Open
Abstract
Bone conduction is a promising haptic feedback modality for upper-limb prosthesis users, however, its potential and characteristics as a non-invasive feedback modality have not been thoroughly investigated. This study aimed to establish the temporal and spatial characteristics of non-invasive bone conduction as a sensory feedback interface for upper-limb prostheses. Psychometric human-subject experiments were conducted on three bony landmarks of the elbow, with a vibrotactile transducer affixed to each to provide the stimulus. The study characterized the temporal domain by testing perception threshold and resolution in amplitude and frequency. The spatial domain was evaluated by assessing the ability of subjects to detect the number of simultaneous active stimulation sites. The experiment was conducted with ten able-bodied subjects and compared to two subjects with trans-radial amputation. The psychometric evaluation of the proposed non-invasive bone conduction feedback showed results comparable to invasive methods. The experimental results demonstrated similar amplitude and frequency resolution of the interface for all three stimulation sites for both able-bodied subjects and subjects with trans-radial amputation, highlighting its potential as a non-invasive feedback modality for upper-limb prostheses.
Collapse
Affiliation(s)
- Raphael M. Mayer
- Department of Mechanical Engineering, The University of Melbourne, Parkville, VIC, Australia
- *Correspondence: Raphael M. Mayer
| | - Alireza Mohammadi
- Department of Mechanical Engineering, The University of Melbourne, Parkville, VIC, Australia
| | - Ying Tan
- Department of Mechanical Engineering, The University of Melbourne, Parkville, VIC, Australia
| | - Gursel Alici
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, NSW, Australia
- ARC Centre of Excellence for Electromaterials Science, Wollongong, NSW, Australia
| | - Peter Choong
- ARC Centre of Excellence for Electromaterials Science, Wollongong, NSW, Australia
- Department of Surgery, St Vincent's Hospital, The University of Melbourne, Parkville, VIC, Australia
| | - Denny Oetomo
- Department of Mechanical Engineering, The University of Melbourne, Parkville, VIC, Australia
- ARC Centre of Excellence for Electromaterials Science, Wollongong, NSW, Australia
| |
Collapse
|
5
|
Pregnolato G, Rimini D, Baldan F, Maistrello L, Salvalaggio S, Celadon N, Ariano P, Pirri CF, Turolla A. Clinical Features to Predict the Use of a sEMG Wearable Device (REMO ®) for Hand Motor Training of Stroke Patients: A Cross-Sectional Cohort Study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:5082. [PMID: 36981992 PMCID: PMC10049214 DOI: 10.3390/ijerph20065082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/29/2023] [Revised: 03/04/2023] [Accepted: 03/09/2023] [Indexed: 06/18/2023]
Abstract
After stroke, upper limb motor impairment is one of the most common consequences that compromises the level of the autonomy of patients. In a neurorehabilitation setting, the implementation of wearable sensors provides new possibilities for enhancing hand motor recovery. In our study, we tested an innovative wearable (REMO®) that detected the residual surface-electromyography of forearm muscles to control a rehabilitative PC interface. The aim of this study was to define the clinical features of stroke survivors able to perform ten, five, or no hand movements for rehabilitation training. 117 stroke patients were tested: 65% of patients were able to control ten movements, 19% of patients could control nine to one movement, and 16% could control no movements. Results indicated that mild upper limb motor impairment (Fugl-Meyer Upper Extremity ≥ 18 points) predicted the control of ten movements and no flexor carpi muscle spasticity predicted the control of five movements. Finally, severe impairment of upper limb motor function (Fugl-Meyer Upper Extremity > 10 points) combined with no pain and no restrictions of upper limb joints predicted the control of at least one movement. In conclusion, the residual motor function, pain and joints restriction, and spasticity at the upper limb are the most important clinical features to use for a wearable REMO® for hand rehabilitation training.
Collapse
Affiliation(s)
- Giorgia Pregnolato
- Laboratory of Healthcare Innovation Technology, IRCCS San Camillo Hospital, Via Alberoni 70, 30126 Venice, Italy; (L.M.); (S.S.)
| | - Daniele Rimini
- Medical Physics Department, Salford Care Organisation, Northern Care Alliance, Salford M6 8HD, UK;
- Division of Cardiovascular Sciences, School of Medical Sciences, Faculty of Biology, Medicine and Health, University Of Manchester, Manchester M13 9PL, UK
| | | | - Lorenza Maistrello
- Laboratory of Healthcare Innovation Technology, IRCCS San Camillo Hospital, Via Alberoni 70, 30126 Venice, Italy; (L.M.); (S.S.)
| | - Silvia Salvalaggio
- Laboratory of Healthcare Innovation Technology, IRCCS San Camillo Hospital, Via Alberoni 70, 30126 Venice, Italy; (L.M.); (S.S.)
- Padova Neuroscience Center, Università degli Studi di Padova, Via Orus 2/B, 35131 Padova, Italy
| | - Nicolò Celadon
- Morecognition s.r.l., 10129 Turin, Italy; (N.C.); (P.A.)
| | - Paolo Ariano
- Morecognition s.r.l., 10129 Turin, Italy; (N.C.); (P.A.)
- Artificial Physiology Group, Center for Sustainable Future Technologies, Istituto Italiano di Tecnologia, Via Livorno 60, 10144 Torino, Italy;
| | - Candido Fabrizio Pirri
- Artificial Physiology Group, Center for Sustainable Future Technologies, Istituto Italiano di Tecnologia, Via Livorno 60, 10144 Torino, Italy;
- Department of Applied Science and Technology, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin, Italy
| | - Andrea Turolla
- Department of Biomedical and Neuromotor Sciences—DIBINEM, Alma Mater Studiorum Università di Bologna, Via Massarenti, 9, 40138 Bologna, Italy;
- Unit of Occupational Medicine, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Via Pelagio Palagi, 9, 40138 Bologna, Italy
| |
Collapse
|
6
|
Use of Surface Electromyography to Estimate End-Point Force in Redundant Systems: Comparison between Linear Approaches. Bioengineering (Basel) 2023; 10:bioengineering10020234. [PMID: 36829728 PMCID: PMC9952324 DOI: 10.3390/bioengineering10020234] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 02/06/2023] [Accepted: 02/07/2023] [Indexed: 02/12/2023] Open
Abstract
Estimation of the force exerted by muscles from their electromyographic (EMG) activity may be useful to control robotic devices. Approximating end-point forces as a linear combination of the activities of multiple muscles acting on a limb may lead to an inaccurate estimation because of the dependency between the EMG signals, i.e., multi-collinearity. This study compared the EMG-to-force mapping estimation performed with standard multiple linear regression and with three other algorithms designed to reduce different sources of the detrimental effects of multi-collinearity: Ridge Regression, which performs an L2 regularization through a penalty term; linear regression with constraints from foreknown anatomical boundaries, derived from a musculoskeletal model; linear regression of a reduced number of muscular degrees of freedom through the identification of muscle synergies. Two datasets, both collected during the exertion of submaximal isometric forces along multiple directions with the upper limb, were exploited. One included data collected across five sessions and the other during the simultaneous exertion of force and generation of different levels of co-contraction. The accuracy and consistency of the EMG-to-force mappings were assessed to determine the strengths and drawbacks of each algorithm. When applied to multiple sessions, Ridge Regression achieved higher accuracy (R2 = 0.70) but estimations based on muscle synergies were more consistent (differences between the pulling vectors of mappings extracted from different sessions: 67%). In contrast, the implementation of anatomical constraints was the best solution, both in terms of consistency (R2 = 0.64) and accuracy (74%), in the case of different co-contraction conditions. These results may be used for the selection of the mapping between EMG and force to be implemented in myoelectrically controlled robotic devices.
Collapse
|
7
|
Earley EJ, Johnson RE, Sensinger JW, Hargrove LJ. Wrist speed feedback improves elbow compensation and reaching accuracy for myoelectric transradial prosthesis users in hybrid virtual reaching task. J Neuroeng Rehabil 2023; 20:9. [PMID: 36658605 PMCID: PMC9850536 DOI: 10.1186/s12984-023-01138-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2022] [Accepted: 01/11/2023] [Indexed: 01/20/2023] Open
Abstract
BACKGROUND Myoelectric prostheses are a popular choice for restoring motor capability following the loss of a limb, but they do not provide direct feedback to the user about the movements of the device-in other words, kinesthesia. The outcomes of studies providing artificial sensory feedback are often influenced by the availability of incidental feedback. When subjects are blindfolded and disconnected from the prosthesis, artificial sensory feedback consistently improves control; however, when subjects wear a prosthesis and can see the task, benefits often deteriorate or become inconsistent. We theorize that providing artificial sensory feedback about prosthesis speed, which cannot be precisely estimated via vision, will improve the learning and control of a myoelectric prosthesis. METHODS In this study, we test a joint-speed feedback system with six transradial amputee subjects to evaluate how it affects myoelectric control and adaptation behavior during a virtual reaching task. RESULTS Our results showed that joint-speed feedback lowered reaching errors and compensatory movements during steady-state reaches. However, the same feedback provided no improvement when control was perturbed. CONCLUSIONS These outcomes suggest that the benefit of joint speed feedback may be dependent on the complexity of the myoelectric control and the context of the task.
Collapse
Affiliation(s)
- Eric J Earley
- Center for Bionic Medicine, Shirley Ryan AbilityLab, Chicago, IL, USA.
- Department of Biomedical Engineering, Northwestern University, Chicago, IL, USA.
- Center for Bionics and Pain Research, Mölndal, Sweden.
- Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden.
| | - Reva E Johnson
- Department of Mechanical Engineering and Bioengineering, Valparaiso University, Valparaiso, IN, USA
| | - Jonathon W Sensinger
- Institute of Biomedical Engineering, University of New Brunswick, Fredericton, NB, Canada
- Department of Electrical and Computer Engineering, University of New Brunswick, Fredericton, NB, Canada
| | - Levi J Hargrove
- Center for Bionic Medicine, Shirley Ryan AbilityLab, Chicago, IL, USA
- Department of Biomedical Engineering, Northwestern University, Chicago, IL, USA
- Department of Physical Medicine and Rehabilitation, Northwestern University, Chicago, IL, USA
| |
Collapse
|
8
|
Borzelli D, Pastorelli S, d’Avella A, Gastaldi L. Virtual Stiffness: A Novel Biomechanical Approach to Estimate Limb Stiffness of a Multi-Muscle and Multi-Joint System. SENSORS (BASEL, SWITZERLAND) 2023; 23:673. [PMID: 36679467 PMCID: PMC9861781 DOI: 10.3390/s23020673] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 12/30/2022] [Accepted: 01/03/2023] [Indexed: 06/17/2023]
Abstract
In recent years, different groups have developed algorithms to control the stiffness of a robotic device through the electromyographic activity collected from a human operator. However, the approaches proposed so far require an initial calibration, have a complex subject-specific muscle model, or consider the activity of only a few pairs of antagonist muscles. This study described and tested an approach based on a biomechanical model to estimate the limb stiffness of a multi-joint, multi-muscle system from muscle activations. The "virtual stiffness" method approximates the generated stiffness as the stiffness due to the component of the muscle-activation vector that does not generate any endpoint force. Such a component is calculated by projecting the vector of muscle activations, estimated from the electromyographic signals, onto the null space of the linear mapping of muscle activations onto the endpoint force. The proposed method was tested by using an upper-limb model made of two joints and six Hill-type muscles and data collected during an isometric force-generation task performed with the upper limb. The null-space projection of the muscle-activation vector approximated the major axis of the stiffness ellipse or ellipsoid. The model provides a good approximation of the voluntary stiffening performed by participants that could be directly implemented in wearable myoelectric controlled devices that estimate, in real-time, the endpoint forces, or endpoint movement, from the mapping between muscle activation and force, without any additional calibrations.
Collapse
Affiliation(s)
- Daniele Borzelli
- Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, 98122 Messina, Italy
- Laboratory of Neuromotor Physiology, IRCCS Santa Lucia Foundation, 00179 Rome, Italy
| | - Stefano Pastorelli
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, 10129 Turin, Italy
| | - Andrea d’Avella
- Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, 98122 Messina, Italy
- Laboratory of Neuromotor Physiology, IRCCS Santa Lucia Foundation, 00179 Rome, Italy
| | - Laura Gastaldi
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, 10129 Turin, Italy
| |
Collapse
|
9
|
Tchimino J, Dideriksen JL, Dosen S. EMG feedback outperforms force feedback in the presence of prosthesis control disturbance. Front Neurosci 2022; 16:952288. [PMID: 36203816 PMCID: PMC9530657 DOI: 10.3389/fnins.2022.952288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Accepted: 08/22/2022] [Indexed: 11/30/2022] Open
Abstract
Closing the prosthesis control loop by providing artificial somatosensory feedback can improve utility and user experience. Additionally, closed-loop control should be more robust with respect to disturbance, but this might depend on the type of feedback provided. Thus, the present study investigates and compares the performance of EMG and force feedback in the presence of control disturbances. Twenty able-bodied subjects and one transradial amputee performed delicate and power grasps with a prosthesis in a functional task, while the control signal gain was temporarily increased (high-gain disturbance) or decreased (low-gain disturbance) without their knowledge. Three outcome measures were considered: the percentage of trials successful in the first attempt (reaction to disturbance), the average number of attempts in trials where the wrong force was initially applied (adaptation to disturbance), and the average completion time of the last attempt in every trial. EMG feedback was shown to offer significantly better performance compared to force feedback during power grasping in terms of reaction to disturbance and completion time. During power grasping with high-gain disturbance, the median first-attempt success rate was significantly higher with EMG feedback (73.3%) compared to that achieved with force feedback (60%). Moreover, the median completion time for power grasps with low-gain disturbance was significantly longer with force feedback than with EMG feedback (3.64 against 2.48 s, an increase of 32%). Contrary to our expectations, there was no significant difference between feedback types with regards to adaptation to disturbances and the two feedback types performed similarly in delicate grasps. The results indicated that EMG feedback displayed better performance than force feedback in the presence of control disturbances, further demonstrating the potential of this approach to provide a reliable prosthesis-user interaction.
Collapse
|
10
|
Gentile C, Cordella F, Zollo L. Hierarchical Human-Inspired Control Strategies for Prosthetic Hands. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22072521. [PMID: 35408135 PMCID: PMC9003226 DOI: 10.3390/s22072521] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2022] [Revised: 03/02/2022] [Accepted: 03/23/2022] [Indexed: 05/14/2023]
Abstract
The abilities of the human hand have always fascinated people, and many studies have been devoted to describing and understanding a mechanism so perfect and important for human activities. Hand loss can significantly affect the level of autonomy and the capability of performing the activities of daily life. Although the technological improvements have led to the development of mechanically advanced commercial prostheses, the control strategies are rather simple (proportional or on/off control). The use of these commercial systems is unnatural and not intuitive, and therefore frequently abandoned by amputees. The components of an active prosthetic hand are the mechatronic device, the decoding system of human biological signals into gestures and the control law that translates all the inputs into desired movements. The real challenge is the development of a control law replacing human hand functions. This paper presents a literature review of the control strategies of prosthetics hands with a multiple-layer or hierarchical structure, and points out the main critical aspects of the current solutions, in terms of human's functions replicated with the prosthetic device. The paper finally provides several suggestions for designing a control strategy able to mimic the functions of the human hand.
Collapse
Affiliation(s)
- Cosimo Gentile
- Unit of Advanced Robotics and Human-Centred Technologies, Università Campus Bio-Medico di Roma, 00128 Rome, Italy; (F.C.); (L.Z.)
- INAIL Prosthetic Center, Vigorso di Budrio, 40054 Bologna, Italy
- Correspondence:
| | - Francesca Cordella
- Unit of Advanced Robotics and Human-Centred Technologies, Università Campus Bio-Medico di Roma, 00128 Rome, Italy; (F.C.); (L.Z.)
| | - Loredana Zollo
- Unit of Advanced Robotics and Human-Centred Technologies, Università Campus Bio-Medico di Roma, 00128 Rome, Italy; (F.C.); (L.Z.)
| |
Collapse
|
11
|
Jabban L, Dupan S, Zhang D, Ainsworth B, Nazarpour K, Metcalfe BW. Sensory Feedback for Upper-Limb Prostheses: Opportunities and Barriers. IEEE Trans Neural Syst Rehabil Eng 2022; 30:738-747. [PMID: 35290188 DOI: 10.1109/tnsre.2022.3159186] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The addition of sensory feedback to upper-limb prostheses has been shown to improve control, increase embodiment, and reduce phantom limb pain. However, most commercial prostheses do not incorporate sensory feedback due to several factors. This paper focuses on the major challenges of a lack of deep understanding of user needs, the unavailability of tailored, realistic outcome measures and the segregation between research on control and sensory feedback. The use of methods such as the Person-Based Approach and co-creation can improve the design and testing process. Stronger collaboration between researchers can integrate different prostheses research areas to accelerate the translation process.
Collapse
|
12
|
Towards online myoelectric control based on muscle synergies-to-force mapping for robotic applications. Neurocomputing 2021. [DOI: 10.1016/j.neucom.2020.08.081] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
13
|
Karczewski AM, Dingle AM, Poore SO. The Need to Work Arm in Arm: Calling for Collaboration in Delivering Neuroprosthetic Limb Replacements. Front Neurorobot 2021; 15:711028. [PMID: 34366820 PMCID: PMC8334559 DOI: 10.3389/fnbot.2021.711028] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Accepted: 06/22/2021] [Indexed: 11/21/2022] Open
Abstract
Over the last few decades there has been a push to enhance the use of advanced prosthetics within the fields of biomedical engineering, neuroscience, and surgery. Through the development of peripheral neural interfaces and invasive electrodes, an individual's own nervous system can be used to control a prosthesis. With novel improvements in neural recording and signal decoding, this intimate communication has paved the way for bidirectional and intuitive control of prostheses. While various collaborations between engineers and surgeons have led to considerable success with motor control and pain management, it has been significantly more challenging to restore sensation. Many of the existing peripheral neural interfaces have demonstrated success in one of these modalities; however, none are currently able to fully restore limb function. Though this is in part due to the complexity of the human somatosensory system and stability of bioelectronics, the fragmentary and as-yet uncoordinated nature of the neuroprosthetic industry further complicates this advancement. In this review, we provide a comprehensive overview of the current field of neuroprosthetics and explore potential strategies to address its unique challenges. These include exploration of electrodes, surgical techniques, control methods, and prosthetic technology. Additionally, we propose a new approach to optimizing prosthetic limb function and facilitating clinical application by capitalizing on available resources. It is incumbent upon academia and industry to encourage collaboration and utilization of different peripheral neural interfaces in combination with each other to create versatile limbs that not only improve function but quality of life. Despite the rapidly evolving technology, if the field continues to work in divided "silos," we will delay achieving the critical, valuable outcome: creating a prosthetic limb that is right for the patient and positively affects their life.
Collapse
Affiliation(s)
| | - Aaron M. Dingle
- Division of Plastic Surgery, Department of Surgery, University of Wisconsin–Madison, Madison, WI, United States
| | | |
Collapse
|
14
|
Tchimino J, Markovic M, Dideriksen JL, Dosen S. The effect of calibration parameters on the control of a myoelectric hand prosthesis using EMG feedback. J Neural Eng 2021; 18. [PMID: 34082406 DOI: 10.1088/1741-2552/ac07be] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2020] [Accepted: 06/03/2021] [Indexed: 11/11/2022]
Abstract
Objective.The implementation of somatosensory feedback in upper limb myoelectric prostheses is an important step towards the restoration of lost sensory-motor functions. EMG feedback is a recently proposed method for closing the control loop wherein the myoelectric signal that drives the prosthesis is also used to generate the feedback provided to the user. Therefore, the characteristics of the myoelectric signal (variability and sensitivity) are likely to significantly affect the ability of the subject to utilize this feedback for online control of the prosthesis.Approach.In the present study, we investigated how the cutoff frequency of the low-pass filter (0.5, 1 and 1.5 Hz) and normalization value (20%, 40% and 60% of the maximum voluntary contraction (MVC)), that are used for the generation of the myoelectric signal, affect the quality of closed-loop control with EMG feedback. Lower cutoff and normalization decrease the intrinsic variability of the EMG but also increase the time lag between the contraction and the feedback (cutoff) as well as the sensitivity of the myoelectric signal (normalization). Ten participants were asked to generate three grasp force levels with a myoelectric prosthetic hand, while receiving five-level vibrotactile EMG feedback, over nine experimental runs (all parameter combinations).Main results.The outcome measure was the success rate (SR) in achieving the appropriate level of myoelectric signal (primary outcome) and grasping force (secondary outcome). Overall, the experiments demonstrated that EMG feedback provided robust control across conditions. Nevertheless, the performance was significantly better for the lowest cutoff (0.5 Hz) and higher normalization (40% and 60%). The highest SR for the EMG was 71.9%, achieved in the condition (40% MVC and 0.5 Hz), and this was 24.1% higher than that in the condition (20% MVC and 1.5 Hz), which resulted in the lowest performance. The SR for the force followed a similar trend.Significance.This is the first study that systematically explored the parameter space for the calibration of EMG feedback, which is a critical step for the future clinical application of this approach.
Collapse
Affiliation(s)
- Jack Tchimino
- Department of Health Science and Technology, Aalborg University, Aalborg, Denmark
| | - Marko Markovic
- Department of Trauma Surgery, Orthopedics and Plastic Surgery, University Medical Center Göttingen, Göttingen, Germany
| | | | - Strahinja Dosen
- Department of Health Science and Technology, Aalborg University, Aalborg, Denmark
| |
Collapse
|
15
|
Earley EJ, Johnson RE, Sensinger JW, Hargrove LJ. Joint speed feedback improves myoelectric prosthesis adaptation after perturbed reaches in non amputees. Sci Rep 2021; 11:5158. [PMID: 33664421 PMCID: PMC7970849 DOI: 10.1038/s41598-021-84795-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Accepted: 02/17/2021] [Indexed: 01/31/2023] Open
Abstract
Accurate control of human limbs involves both feedforward and feedback signals. For prosthetic arms, feedforward control is commonly accomplished by recording myoelectric signals from the residual limb to predict the user's intent, but augmented feedback signals are not explicitly provided in commercial devices. Previous studies have demonstrated inconsistent results when artificial feedback was provided in the presence of vision; some studies showed benefits, while others did not. We hypothesized that negligible benefits in past studies may have been due to artificial feedback with low precision compared to vision, which results in heavy reliance on vision during reaching tasks. Furthermore, we anticipated more reliable benefits from artificial feedback when providing information that vision estimates with high uncertainty (e.g. joint speed). In this study, we test an artificial sensory feedback system providing joint speed information and how it impacts performance and adaptation during a hybrid positional-and-myoelectric ballistic reaching task. We found that overall reaching errors were reduced after perturbed control, but did not significantly improve steady-state reaches. Furthermore, we found that feedback about the joint speed of the myoelectric prosthesis control improved the adaptation rate of biological limb movements, which may have resulted from high prosthesis control noise and strategic overreaching with the positional control and underreaching with the myoelectric control. These results provide insights into the relevant factors influencing the improvements conferred by artificial sensory feedback.
Collapse
Affiliation(s)
- Eric J Earley
- Department of Biomedical Engineering, Northwestern University, Chicago, IL, USA.
- Center for Bionic Medicine, Shirley Ryan AbilityLab, Chicago, IL, USA.
| | - Reva E Johnson
- Department of Mechanical Engineering and Bioengineering, Valparaiso University, Valparaiso, IN, USA
| | - Jonathon W Sensinger
- Institute of Biomedical Engineering, University of New Brunswick, Fredericton, NB, Canada
- Department of Electrical and Computer Engineering, University of New Brunswick, Fredericton, NB, Canada
| | - Levi J Hargrove
- Department of Biomedical Engineering, Northwestern University, Chicago, IL, USA
- Center for Bionic Medicine, Shirley Ryan AbilityLab, Chicago, IL, USA
- Department of Physical Medicine and Rehabilitation, Northwestern University, Chicago, IL, USA
| |
Collapse
|
16
|
Cappello L, Alghilan W, Gabardi M, Leonardis D, Barsotti M, Frisoli A, Cipriani C. Continuous supplementary tactile feedback can be applied (and then removed) to enhance precision manipulation. J Neuroeng Rehabil 2020; 17:120. [PMID: 32859222 PMCID: PMC7456017 DOI: 10.1186/s12984-020-00736-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2020] [Accepted: 07/29/2020] [Indexed: 11/24/2022] Open
Abstract
Background Human sensorimotor control of dexterous manipulation relies on afferent sensory signals. Explicit tactile feedback is generally not available to prosthetic hand users, who have to rely on incidental information sources to partly close the control loop, resulting in suboptimal performance and manipulation difficulty. Recent studies on non-invasive supplementary sensory feedback indicated that time-discrete vibrational feedback delivered upon relevant mechanical events outperforms continuous tactile feedback. However, we hypothesize that continuous tactile feedback can be more effective in non-routine manipulation tasks (i.e., tasks where the grip force is modified reactively in response to the sensory feedback due to the unpredictable behavior of the manipulated object, such as picking and holding a virtual fragile object) if delivered to highly sensitive areas. We further hypothesize that this continuous tactile feedback is not necessary during all the duration of the manipulation task, since adaptation occurs. Methods We investigated the effectiveness of continuous tactile feedback in precision manipulation, together with a new sensory feedback policy, where the continuous tactile feedback is gradually removed when the grasp reaches a steady state (namely, transient tactile feedback). We carried out an experiment in a virtual-reality setting with custom tactile feedback devices, which can apply continuous pressure and vibrations, attached to the thumb and index finger. We enrolled 24 healthy participants and instructed them to pick and hold a fragile virtual cube without breaking it. We compared their manipulation performance when using four different sensory feedback methods, i.e., no tactile feedback, discrete vibrations, continuous tactile feedback, and transient tactile feedback. The latter consisted of gradually removing the continuous feedback in the static phase of the grasp. Results Continuous tactile feedback leads to a significantly larger number of successful trials than discrete vibrational cues and no feedback conditions, yet the gradual removal of the continuous feedback yields to comparable outcomes. Moreover, the participants preferred the continuous stimuli over the vibrational cues and the removal in the static phase did not significantly impact their appreciation of the continuous tactile feedback. Conclusions These results advocate for the use of continuous supplementary tactile feedback for fine manipulation control and indicate that it can seamlessly be removed in the static phase of the grasp, possibly due to the mechanism of sensory adaptation. This encourages the development of energy-efficient supplementary feedback devices for prosthetic and telemanipulation applications, where encumbrance and power consumption are burdensome constraints.
Collapse
Affiliation(s)
- Leonardo Cappello
- Scuola Superiore Sant'Anna, The BioRobotics Institute, Pisa, Italy. .,Scuola Superiore Sant'Anna, Department of Excellence in Robotics & AI, Pisa, Italy.
| | - Waleed Alghilan
- Scuola Superiore Sant'Anna, The BioRobotics Institute, Pisa, Italy.,Scuola Superiore Sant'Anna, Department of Excellence in Robotics & AI, Pisa, Italy
| | - Massimiliano Gabardi
- Scuola Superiore Sant'Anna, Department of Excellence in Robotics & AI, Pisa, Italy.,Scuola Superiore Sant'Anna, TeCIP Institute, PERCRO Laboratory, Pisa, Italy
| | - Daniele Leonardis
- Scuola Superiore Sant'Anna, Department of Excellence in Robotics & AI, Pisa, Italy.,Scuola Superiore Sant'Anna, TeCIP Institute, PERCRO Laboratory, Pisa, Italy
| | - Michele Barsotti
- Scuola Superiore Sant'Anna, Department of Excellence in Robotics & AI, Pisa, Italy.,Scuola Superiore Sant'Anna, TeCIP Institute, PERCRO Laboratory, Pisa, Italy
| | - Antonio Frisoli
- Scuola Superiore Sant'Anna, Department of Excellence in Robotics & AI, Pisa, Italy.,Scuola Superiore Sant'Anna, TeCIP Institute, PERCRO Laboratory, Pisa, Italy
| | - Christian Cipriani
- Scuola Superiore Sant'Anna, The BioRobotics Institute, Pisa, Italy.,Scuola Superiore Sant'Anna, Department of Excellence in Robotics & AI, Pisa, Italy
| |
Collapse
|
17
|
Garenfeld MA, Mortensen CK, Strbac M, Dideriksen JL, Dosen S. Amplitude versus spatially modulated electrotactile feedback for myoelectric control of two degrees of freedom. J Neural Eng 2020; 17:046034. [PMID: 32650320 DOI: 10.1088/1741-2552/aba4fd] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
OBJECTIVE Artificial proprioceptive feedback from a myoelectric prosthesis is an important aspect in enhancing embodiment and user satisfaction, possibly lowering the demand for visual attention while controlling a prosthesis in everyday tasks. Contemporary myoelectric prostheses are advanced mechatronic systems with multiple degrees of freedom, and therefore, to communicate the prosthesis state, the feedback interface needs to transmit several variables simultaneously. In the present study, two different configurations for conveying proprioceptive information of wrist rotation and hand aperture through multichannel electrotactile stimulation were developed and evaluated during online myoelectric control. APPROACH Myoelectric recordings were acquired from the dominant forearm and electrotactile stimulation was delivered on the non-dominant forearm using a compact interface. The first feedback configuration, which was based on spatial coding, transmitted the information using a moving tactile stimulus, whereas the second, amplitude-based configuration conveyed the position via sensation intensity. Thirteen able-bodied subjects used pattern classification-based myoelectric control with both feedback configurations to accomplish a target-reaching task. MAIN RESULTS High task performance (completion rate > 90%) was observed for both configurations, with no significant difference in completion rate, time to reach the target, distance error and path efficiency, respectively. SIGNIFICANCE Overall, the results demonstrated that both feedback configurations allowed subjects to perceive and interpret two feedback variables delivered simultaneously, despite using a compact stimulation interface. This is an encouraging result for the prospect of communicating the full state of a multifunctional hand prosthesis.
Collapse
Affiliation(s)
- Martin A Garenfeld
- Department of Health Science and Technology, Aalborg University, Frederik Bajers Vej 7D, 9220, Aalborg Ø, Denmark
| | | | | | | | | |
Collapse
|
18
|
Wijk U, Carlsson IK, Antfolk C, Björkman A, Rosén B. Sensory Feedback in Hand Prostheses: A Prospective Study of Everyday Use. Front Neurosci 2020; 14:663. [PMID: 32733187 PMCID: PMC7358396 DOI: 10.3389/fnins.2020.00663] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2019] [Accepted: 05/29/2020] [Indexed: 01/19/2023] Open
Abstract
Introduction Sensory feedback in hand prostheses is lacking but wished for. Many amputees experience a phantom hand map on their residual forearm. When the phantom hand map is touched, it is experienced as touch on the amputated hand. A non-invasive sensory feedback system, applicable to existing hand prostheses, can transfer somatotopical sensory information via phantom hand map. The aim was to evaluate how forearm amputees experienced a non-invasive sensory feedback system used in daily life over a 4-week period. Methods This longitudinal cohort study included seven forearm amputees. A non-invasive sensory feedback system was used over 4 weeks. For analysis, a mixed method was used, including quantitative tests (ACMC, proprioceptive pointing task, questionnaire) and interviews. A directed content analysis with predefined categories sensory feedback from the prosthesis, agency, body ownership, performance in activity, and suggestions for improvements was applied. Results The results from interviews showed that sensory feedback was experienced as a feeling of touch which contributed to an experience of completeness. However, the results from the questionnaire showed that the sense of agency and performance remained unchanged or deteriorated. The ability to feel and manipulate small objects was difficult and a stronger feedback was wished for. Phantom pain was alleviated in four out of five patients. Conclusion This is the first time a non-invasive sensory feedback system for hand prostheses was implemented in the home environment. The qualitative and quantitative results diverged. The sensory feedback was experienced as a feeling of touch which contributed to a feeling of completeness, linked to body ownership. The qualitative result was not verified in the quantitative measurements. Clinical Trial Registration Name: Evaluation of a Non-invasive Sensory Feedback System in Hand Prostheses. Date of registration: March 15, 2019. Date the first participant was enrolled: April 1, 2015. ClinicalTrials.gov Identifier: NCT03876405 ORCID ID: https://orcid.org/0000-0002-4140-7478.
Collapse
Affiliation(s)
- Ulrika Wijk
- Department of Translational Medicine, Faculty of Medicine, Lund University, Malmö, Sweden.,Skåne University Hospital, Lund, Sweden
| | - Ingela K Carlsson
- Department of Translational Medicine, Faculty of Medicine, Lund University, Malmö, Sweden.,Skåne University Hospital, Lund, Sweden
| | - Christian Antfolk
- Department of Biomedical Engineering, Faculty of Engineering, Lund University, Lund, Sweden
| | - Anders Björkman
- Department of Translational Medicine, Faculty of Medicine, Lund University, Malmö, Sweden.,Skåne University Hospital, Lund, Sweden
| | - Birgitta Rosén
- Department of Translational Medicine, Faculty of Medicine, Lund University, Malmö, Sweden.,Skåne University Hospital, Lund, Sweden
| |
Collapse
|
19
|
Mastinu E, Engels LF, Clemente F, Dione M, Sassu P, Aszmann O, Brånemark R, Håkansson B, Controzzi M, Wessberg J, Cipriani C, Ortiz-Catalan M. Neural feedback strategies to improve grasping coordination in neuromusculoskeletal prostheses. Sci Rep 2020; 10:11793. [PMID: 32678121 PMCID: PMC7367346 DOI: 10.1038/s41598-020-67985-5] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Accepted: 06/11/2020] [Indexed: 11/09/2022] Open
Abstract
Conventional prosthetic arms suffer from poor controllability and lack of sensory feedback. Owing to the absence of tactile sensory information, prosthetic users must rely on incidental visual and auditory cues. In this study, we investigated the effect of providing tactile perception on motor coordination during routine grasping and grasping under uncertainty. Three transhumeral amputees were implanted with an osseointegrated percutaneous implant system for direct skeletal attachment and bidirectional communication with implanted neuromuscular electrodes. This neuromusculoskeletal prosthesis is a novel concept of artificial limb replacement that allows to extract control signals from electrodes implanted on viable muscle tissue, and to stimulate severed afferent nerve fibers to provide somatosensory feedback. Subjects received tactile feedback using three biologically inspired stimulation paradigms while performing a pick and lift test. The grasped object was instrumented to record grasping and lifting forces and its weight was either constant or unexpectedly changed in between trials. The results were also compared to the no-feedback control condition. Our findings confirm, in line with the neuroscientific literature, that somatosensory feedback is necessary for motor coordination during grasping. Our results also indicate that feedback is more relevant under uncertainty, and its effectiveness can be influenced by the selected neuromodulation paradigm and arguably also the prior experience of the prosthesis user.
Collapse
Affiliation(s)
- Enzo Mastinu
- Center for Bionics and Pain Research, Mölndal, Sweden
- Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden
| | - Leonard F Engels
- The Biorobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
| | - Francesco Clemente
- The Biorobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
- Prensilia SRL, Pontedera, Italy
| | - Mariama Dione
- Department of Physiology, Institute of Neuroscience and Physiology, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Paolo Sassu
- Department of Hand Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Oskar Aszmann
- Clinical Laboratory for Bionic Extremity Reconstruction, Division of Plastic and Reconstructive Surgery, Medical University of Vienna, Vienna, Austria
| | - Rickard Brånemark
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Center for Extreme Bionics, Biomechatronics Group, MIT Media Lab, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Bo Håkansson
- Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden
| | - Marco Controzzi
- The Biorobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
| | - Johan Wessberg
- Department of Physiology, Institute of Neuroscience and Physiology, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Christian Cipriani
- The Biorobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy
- Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, Pisa, Italy
| | - Max Ortiz-Catalan
- Center for Bionics and Pain Research, Mölndal, Sweden.
- Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden.
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
- Operational Area 3, Sahlgrenska University Hospital, Mölndal, Sweden.
| |
Collapse
|
20
|
Wilke MA, Hartmann C, Schimpf F, Farina D, Dosen S. The Interaction Between Feedback Type and Learning in Routine Grasping With Myoelectric Prostheses. IEEE TRANSACTIONS ON HAPTICS 2020; 13:645-654. [PMID: 31870991 DOI: 10.1109/toh.2019.2961652] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
While prosthetic fitting after upper-limb loss allows for restoration of motor functions, it deprives the amputee of tactile sensations that are essential for grasp control in able-bodied subjects. Therefore, it is commonly assumed that restoring the force feedback would improve the control of prosthesis grasping force. However, the literature regarding the benefit of feedback is controversial. Here, we investigated how the type of feedback affects learning and steady-state performance of routine grasping with a prosthesis. The experimental task was to grasp an object using a prosthesis and generate a low or high target-force range (TFR), both initially unknown, in three feedback conditions: basic auditory feedback on task outcome, and additional visual or vibratory feedback on the force magnitude. The results demonstrated that the performance was rather good and stable for the low TFR, whereas it was substantially worse for the high TFR with a pronounced training effect. Surprisingly, learning curve and steady-state performance did not depend on the feedback condition. Hence, in the specific context of routing grasping with a prosthesis controlled via surface EMG, the basic feedback on task outcome was not outperformed by force-related end-of-trial feedback and hence seemed to be sufficient for accomplishing the task.This conclusion applies to the context of routine grasping using a myoelectric prosthesis with surface EMG electrodes, which means that the control signals are variable and the feedback is perceived and processed at the end of the trial (motor adaption).
Collapse
|
21
|
Sensinger JW, Dosen S. A Review of Sensory Feedback in Upper-Limb Prostheses From the Perspective of Human Motor Control. Front Neurosci 2020; 14:345. [PMID: 32655344 PMCID: PMC7324654 DOI: 10.3389/fnins.2020.00345] [Citation(s) in RCA: 60] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2019] [Accepted: 03/23/2020] [Indexed: 12/22/2022] Open
Abstract
This manuscript reviews historical and recent studies that focus on supplementary sensory feedback for use in upper limb prostheses. It shows that the inability of many studies to speak to the issue of meaningful performance improvements in real-life scenarios is caused by the complexity of the interactions of supplementary sensory feedback with other types of feedback along with other portions of the motor control process. To do this, the present manuscript frames the question of supplementary feedback from the perspective of computational motor control, providing a brief review of the main advances in that field over the last 20 years. It then separates the studies on the closed-loop prosthesis control into distinct categories, which are defined by relating the impact of feedback to the relevant components of the motor control framework, and reviews the work that has been done over the last 50+ years in each of those categories. It ends with a discussion of the studies, along with suggestions for experimental construction and connections with other areas of research, such as machine learning.
Collapse
Affiliation(s)
- Jonathon W. Sensinger
- Institute of Biomedical Engineering, University of New Brunswick, Fredericton, NB, Canada
| | - Strahinja Dosen
- Department of Health Science and Technology, The Faculty of Medicine, Integrative Neuroscience, Aalborg University, Aalborg, Denmark
| |
Collapse
|
22
|
Mayer RM, Garcia-Rosas R, Mohammadi A, Tan Y, Alici G, Choong P, Oetomo D. Tactile Feedback in Closed-Loop Control of Myoelectric Hand Grasping: Conveying Information of Multiple Sensors Simultaneously via a Single Feedback Channel. Front Neurosci 2020; 14:348. [PMID: 32395102 PMCID: PMC7197324 DOI: 10.3389/fnins.2020.00348] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Accepted: 03/23/2020] [Indexed: 12/03/2022] Open
Abstract
The appropriate sensory information feedback is important for the success of an object grasping and manipulation task. In many scenarios, the need arises for multiple feedback information to be conveyed to a prosthetic hand user simultaneously. The multiple sets of information may either (1) directly contribute to the performance of the grasping or object manipulation task, such as the feedback of the grasping force, or (2) simply form additional independent set(s) of information. In this paper, the efficacy of simultaneously conveying two independent sets of sensor information (the grasp force and a secondary set of information) through a single channel of feedback stimulation (vibrotactile via bone conduction) to the human user in a prosthetic application is investigated. The performance of the grasping task is not dependent to the second set of information in this study. Subject performance in two tasks: regulating the grasp force and identifying the secondary information, were evaluated when provided with either one corresponding information or both sets of feedback information. Visual feedback is involved in the training stage. The proposed approach is validated on human-subject experiments using a vibrotactile transducer worn on the elbow bony landmark (to realize a non-invasive bone conduction interface) carried out in a virtual reality environment to perform a closed-loop object grasping task. The experimental results show that the performance of the human subjects on either task, whilst perceiving two sets of sensory information, is not inferior to that when receiving only one set of corresponding sensory information, demonstrating the potential of conveying a second set of information through a bone conduction interface in an upper limb prosthetic task.
Collapse
Affiliation(s)
- Raphael M Mayer
- Human Robotics Laboratory, Department of Mechanical Engineering, The University of Melbourne, Parkville, VIC, Australia
| | - Ricardo Garcia-Rosas
- Human Robotics Laboratory, Department of Mechanical Engineering, The University of Melbourne, Parkville, VIC, Australia
| | - Alireza Mohammadi
- Human Robotics Laboratory, Department of Mechanical Engineering, The University of Melbourne, Parkville, VIC, Australia
| | - Ying Tan
- Human Robotics Laboratory, Department of Mechanical Engineering, The University of Melbourne, Parkville, VIC, Australia
| | - Gursel Alici
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, NSW, Australia.,ARC Centre of Excellence for Electromaterials Science, Wollongong, NSW, Australia
| | - Peter Choong
- ARC Centre of Excellence for Electromaterials Science, Wollongong, NSW, Australia.,Department of Surgery, St. Vincent's Hospital, The University of Melbourne, Parkville, VIC, Australia
| | - Denny Oetomo
- Human Robotics Laboratory, Department of Mechanical Engineering, The University of Melbourne, Parkville, VIC, Australia.,ARC Centre of Excellence for Electromaterials Science, Wollongong, NSW, Australia
| |
Collapse
|
23
|
Patwardhan S, Dhawan AS, Mukherjee B, Alzamani M, Joiner WM, Sikdar S. Evaluation of the Role of Proprioception During Proportional Position Control Using Sonomyography: Applications in Prosthetic Control. IEEE Int Conf Rehabil Robot 2020; 2019:830-836. [PMID: 31374733 DOI: 10.1109/icorr.2019.8779559] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Prosthetics need to incorporate the users sense of proprioception into the control paradigm to provide intuitive control, and reduce training times and prosthetic rejection rates. In the absence of functional tasks with a prosthetic, virtual cursor control tasks have been used to train users to control multiple degrees of freedom. In this study, A proportional position signal was derived from the cross-sectional ultrasound images of the users forearm. We designed a virtual cursor control task with one degree of freedom to measure the users ability to repeatably and accurately acquire different levels of muscle flexion, using only their sense of proprioception. The experiment involved a target acquisition task, where the cursors height corresponded to the extent of muscle flexion. Users were asked to acquire targets on a screen. Visual feedback was disabled at certain times during the experiment, to isolate the effect of proprioception. We found that as visual feedback was taken away from the subjects, position error increased but their stability error did not change significantly. This indicates that users are not perfect at using only their proprioceptive sense to reacquire a level of muscle flexion, in the absence of haptic or visual feedback. However, they are adept at retaining an acquired flexion level without drifting. These results could help to quantify the role of proprioception in target acquisition tasks, in the absence of haptic or visual feedback.
Collapse
|
24
|
Wilke MA, Niethammer C, Meyer B, Farina D, Dosen S. Psychometric characterization of incidental feedback sources during grasping with a hand prosthesis. J Neuroeng Rehabil 2019; 16:155. [PMID: 31823792 PMCID: PMC6902515 DOI: 10.1186/s12984-019-0622-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Accepted: 11/13/2019] [Indexed: 11/17/2022] Open
Abstract
Background A prosthetic system should ideally reinstate the bidirectional communication between the user’s brain and its end effector by restoring both motor and sensory functions lost after an amputation. However, current commercial prostheses generally do not incorporate somatosensory feedback. Even without explicit feedback, grasping using a prosthesis partly relies on sensory information. Indeed, the prosthesis operation is characterized by visual and sound cues that could be exploited by the user to estimate the prosthesis state. However, the quality of this incidental feedback has not been objectively evaluated. Methods In this study, the psychometric properties of the auditory and visual feedback of prosthesis motion were assessed and compared to that of a vibro-tactile interface. Twelve able-bodied subjects passively observed prosthesis closing and grasping an object, and they were asked to discriminate (experiment I) or estimate (experiment II) the closing velocity of the prosthesis using visual (VIS), acoustic (SND), or combined (VIS + SND) feedback. In experiment II, the subjects performed the task also with a vibrotactile stimulus (VIB) delivered using a single tactor. The outcome measures for the discrimination and estimation experiments were just noticeable difference (JND) and median absolute estimation error (MAE), respectively. Results The results demonstrated that the incidental sources provided a remarkably good discrimination and estimation of the closing velocity, significantly outperforming the vibrotactile feedback. Using incidental sources, the subjects could discriminate almost the minimum possible increment/decrement in velocity that could be commanded to the prosthesis (median JND < 2% for SND and VIS + SND). Similarly, the median MAE in estimating the prosthesis velocity randomly commanded from the full working range was also low, i.e., approximately 5% in SND and VIS + SND. Conclusions Since the closing velocity is proportional to grasping force in state-of-the-art myoelectric prostheses, the results of the present study imply that the incidental feedback, when available, could be usefully exploited for grasping force control. Therefore, the impact of incidental feedback needs to be considered when designing a feedback interface in prosthetics, especially since the quality of estimation using supplemental sources (e.g., vibration) can be worse compared to that of the intrinsic cues.
Collapse
Affiliation(s)
- Meike Annika Wilke
- Department of Biotechnology, University for Applied Sciences Hamburg, Hamburg, Germany. .,Advanced Rehabilitation Technology (ART) Lab, Department for Trauma Surgery, Orthopaedics and Plastic Surgery, Universitätsmedizin Göttingen (UMG), Göttingen, Germany.
| | - Christian Niethammer
- Advanced Rehabilitation Technology (ART) Lab, Department for Trauma Surgery, Orthopaedics and Plastic Surgery, Universitätsmedizin Göttingen (UMG), Göttingen, Germany.,Department of Computer Science, Eberhard-Karls University Tübingen, Tübingen, Germany
| | - Britta Meyer
- Advanced Rehabilitation Technology (ART) Lab, Department for Trauma Surgery, Orthopaedics and Plastic Surgery, Universitätsmedizin Göttingen (UMG), Göttingen, Germany
| | - Dario Farina
- Advanced Rehabilitation Technology (ART) Lab, Department for Trauma Surgery, Orthopaedics and Plastic Surgery, Universitätsmedizin Göttingen (UMG), Göttingen, Germany.,Department of Bioengineering, Imperial College London, London, UK
| | - Strahinja Dosen
- Advanced Rehabilitation Technology (ART) Lab, Department for Trauma Surgery, Orthopaedics and Plastic Surgery, Universitätsmedizin Göttingen (UMG), Göttingen, Germany.,Department of Health Science and Technology, Center for Sensory-Motor Interaction, Aalborg University, Aalborg, Denmark
| |
Collapse
|
25
|
Dong J, Geng B, Niazi IK, Amjad I, Dosen S, Jensen W, Kamavuako EN. The Variability of Psychophysical Parameters Following Surface and Subdermal Stimulation: A Multiday Study in Amputees. IEEE Trans Neural Syst Rehabil Eng 2019; 28:174-180. [PMID: 31796411 DOI: 10.1109/tnsre.2019.2956836] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Electrotactile stimulation has been suggested as a modality for providing sensory feedback in upper limb prostheses. This study investigates the multiday variability of subdermal and surface stimulation. Electrical stimulation was delivered using either surface or fine wire electrodes placed right under the skin in eight amputees for seven consecutive days. The variability of psychophysical measurements, including detection threshold (DT), pain threshold (PT), dynamic range (DR), just noticeable difference (JND), Weber fraction (WF) and quality of evoked sensations, was evaluated using the coefficient of variation (CoV). In addition, the systematic change in the mean of the parameters across days was assessed in both stimulation modalities. In the case of DT, PT, DR, and perceived intensity at 100 Hz, the CoV of surface stimulation was significantly smaller than that of subdermal stimulation. Only PT showed a significant systematic change in the mean value across days for both modalities. The outcome of this study has implications for the choice of modality in delivering sensory feedback, though the significance of the quantified variability needs to be evaluated using usability tests with user feedback.
Collapse
|
26
|
Abstract
State-of-the-art high-end prostheses are electro-mechanically able to provide a great variety of movements. Nevertheless, in order to functionally replace a human limb, it is essential that each movement is properly controlled. This is the goal of prosthesis control, which has become a growing research field in the last decades, with the ultimate goal of reproducing biological limb control. Therefore, exploration and development of prosthesis control are crucial to improve many aspects of an amputee’s life. Nowadays, a large divergence between academia and industry has become evident in commercial systems. Although several studies propose more natural control systems with promising results, basic one degree of freedom (DoF), a control switching system is the most widely used option in industry because of simplicity, robustness and inertia. A few classification controlled prostheses have emerged in the last years but they are still a low percentage of the used ones. One of the factors that generate this situation is the lack of robustness of more advanced control algorithms in daily life activities outside of laboratory conditions. Because of this, research has shifted towards more functional prosthesis control. This work reviews the most recent literature in upper limb prosthetic control. It covers commonly used variants of possible biological inputs, its processing and translation to actual control, mostly focusing on electromyograms as well as the problems it will have to overcome in near future.
Collapse
|
27
|
Engels LF, Shehata AW, Scheme EJ, Sensinger JW, Cipriani C. When Less Is More - Discrete Tactile Feedback Dominates Continuous Audio Biofeedback in the Integrated Percept While Controlling a Myoelectric Prosthetic Hand. Front Neurosci 2019; 13:578. [PMID: 31244596 PMCID: PMC6563774 DOI: 10.3389/fnins.2019.00578] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2019] [Accepted: 05/21/2019] [Indexed: 11/13/2022] Open
Abstract
State of the art myoelectric hand prostheses can restore some feedforward motor function to their users, but they cannot yet restore sensory feedback. It has been shown, using psychophysical tests, that multi-modal sensory feedback is readily used in the formation of the users' representation of the control task in their central nervous system - their internal model. Hence, to fully describe the effect of providing feedback to prosthesis users, not only should functional outcomes be assessed, but so should the internal model. In this study, we compare the complex interactions between two different feedback types, as well as a combination of the two, on the internal model, and the functional performance of naïve participants without limb difference. We show that adding complementary audio biofeedback to visual feedback enables the development of a significantly stronger internal model for controlling a myoelectric hand compared to visual feedback alone, but adding discrete vibrotactile feedback to vision does not. Both types of feedback, however, improved the functional grasping abilities to a similar degree. Contrary to our expectations, when both types of feedback are combined, the discrete vibrotactile feedback seems to dominate the continuous audio feedback. This finding indicates that simply adding sensory information may not necessarily enhance the formation of the internal model in the short term. In fact, it could even degrade it. These results support our argument that assessment of the internal model is crucial to understanding the effects of any type of feedback, although we cannot be sure that the metrics used here describe the internal model exhaustively. Furthermore, all the feedback types tested herein have been proven to provide significant functional benefits to the participants using a myoelectrically controlled robotic hand. This article, therefore, proposes a crucial conceptual and methodological addition to the evaluation of sensory feedback for upper limb prostheses - the internal model - as well as new types of feedback that promise to significantly and considerably improve functional prosthesis control.
Collapse
Affiliation(s)
- Leonard F Engels
- The BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy
| | - Ahmed W Shehata
- Division of Physical Medicine and Rehabilitation, Department of Medicine, University of Alberta, Edmonton, AB, Canada
| | - Erik J Scheme
- Department of Electrical and Computer Engineering, Institute of Biomedical Engineering, University of New Brunswick, Fredericton, NB, Canada
| | - Jonathon W Sensinger
- Department of Electrical and Computer Engineering, Institute of Biomedical Engineering, University of New Brunswick, Fredericton, NB, Canada
| | | |
Collapse
|
28
|
Fu Q, Shao F, Santello M. Inter-Limb Transfer of Grasp Force Perception With Closed-Loop Hand Prosthesis. IEEE Trans Neural Syst Rehabil Eng 2019; 27:927-936. [PMID: 31021799 DOI: 10.1109/tnsre.2019.2911893] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Sensory feedback of grasp forces provides important information about physical interactions between the hand and objects, enabling both reactive and anticipatory neural control mechanisms. The numerous studies have shown artificial sensory feedback of various forms improves force control during grasping tasks by prosthetic hand users through a closed-feedback loop. However, little is known about how perceptual information is transferred between an intact limb and a closed-loop prosthetic limb, and the extent to which training inter-limb transfer may improve myoelectric prosthetic control. We addressed these gaps by using a contralateral force-matching task in which able-bodied participants were asked to generate grasp forces with their native hand, and then match it using the contralateral hand or a soft-synergy prosthetic hand worn on the contralateral arm that was coupled with a mechanotactile feedback device. We found that absolute matching error and matching time were greater when using the prosthetic system than the native hand. However, with contralateral specific training, subjects were able to produce similar relative matching error with the prosthetic system and the native hand, especially at the untrained force level. These findings suggest that an association can be established between the perception produced by the prosthetic limb and the contralateral intact limb, and provide novel insights about potential applications to training and design of the closed-loop prosthesis.
Collapse
|
29
|
Mastinu E, Clemente F, Sassu P, Aszmann O, Brånemark R, Håkansson B, Controzzi M, Cipriani C, Ortiz-Catalan M. Grip control and motor coordination with implanted and surface electrodes while grasping with an osseointegrated prosthetic hand. J Neuroeng Rehabil 2019; 16:49. [PMID: 30975158 PMCID: PMC6460734 DOI: 10.1186/s12984-019-0511-2] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2018] [Accepted: 03/05/2019] [Indexed: 11/13/2022] Open
Abstract
Background Replacement of a lost limb by an artificial substitute is not yet ideal. Resolution and coordination of motor control approximating that of a biological limb could dramatically improve the functionality of prosthetic devices, and thus reduce the gap towards a suitable limb replacement. Methods In this study, we investigated the control resolution and coordination exhibited by subjects with transhumeral amputation who were implanted with epimysial electrodes and an osseointegrated interface that provides bidirectional communication in addition to skeletal attachment (e-OPRA Implant System). We assessed control resolution and coordination in the context of routine and delicate grasping using the Pick and Lift and the Virtual Eggs Tests. Performance when utilizing implanted electrodes was compared with the standard-of-care technology for myoelectric prostheses, namely surface electrodes. Results Results showed that implanted electrodes provide superior controllability over the prosthetic terminal device compared to conventional surface electrodes. Significant improvements were found in the control of the grip force and its reliability during object transfer. However, these improvements failed to increase motor coordination, and surprisingly decreased the temporal correlation between grip and load forces observed with surface electrodes. We found that despite being more functional and reliable, prosthetic control via implanted electrodes still depended highly on visual feedback. Conclusions Our findings indicate that incidental sensory feedback (visual, auditory, and osseoperceptive in this case) is insufficient for restoring natural grasp behavior in amputees, and support the idea that supplemental tactile sensory feedback is needed to learn and maintain the motor tasks internal model, which could ultimately restore natural grasp behavior in subjects using prosthetic hands.
Collapse
Affiliation(s)
- Enzo Mastinu
- Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden.
| | - Francesco Clemente
- The Biorobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy.,Prensilia SRL, Pisa, Italy
| | - Paolo Sassu
- Department of Hand Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Oskar Aszmann
- Christian Doppler Laboratory for Restoration of Extremity Function, Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Rickard Brånemark
- Department of Orthopaedics, Gothenburg University, Gothenburg, Sweden
| | - Bo Håkansson
- Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden
| | - Marco Controzzi
- The Biorobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy
| | | | - Max Ortiz-Catalan
- Department of Electrical Engineering, Chalmers University of Technology, Gothenburg, Sweden
| |
Collapse
|