1
|
Abstract
Development and implementation of neuroprosthetic hands is a multidisciplinary field at the interface between humans and artificial robotic systems, which aims at replacing the sensorimotor function of the upper-limb amputees as their own. Although prosthetic hand devices with myoelectric control can be dated back to more than 70 years ago, their applications with anthropomorphic robotic mechanisms and sensory feedback functions are still at a relatively preliminary and laboratory stage. Nevertheless, a recent series of proof-of-concept studies suggest that soft robotics technology may be promising and useful in alleviating the design complexity of the dexterous mechanism and integration difficulty of multifunctional artificial skins, in particular, in the context of personalized applications. Here, we review the evolution of neuroprosthetic hands with the emerging and cutting-edge soft robotics, covering the soft and anthropomorphic prosthetic hand design and relating bidirectional neural interactions with myoelectric control and sensory feedback. We further discuss future opportunities on revolutionized mechanisms, high-performance soft sensors, and compliant neural-interaction interfaces for the next generation of neuroprosthetic hands.
Collapse
Affiliation(s)
- Guoying Gu
- Robotics Institute, State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
- Meta Robotics Institute, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Ningbin Zhang
- Robotics Institute, State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Chen Chen
- Robotics Institute, State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Haipeng Xu
- Robotics Institute, State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Xiangyang Zhu
- Robotics Institute, State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
- Meta Robotics Institute, Shanghai Jiao Tong University, Shanghai 200240, China
| |
Collapse
|
2
|
Choi MH, Kim KB, Kim YJ, Kim JS, Kim HS, Chung SC. Study on the Cognitive Characteristics Induced by Changes in the Intensity, Frequency and Duration of Vibratory Stimuli. Behav Sci (Basel) 2023; 13:bs13050350. [PMID: 37232587 DOI: 10.3390/bs13050350] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 04/11/2023] [Accepted: 04/20/2023] [Indexed: 05/27/2023] Open
Abstract
The purpose of this study is to analyze the cognitive characteristics that can be induced by vibration stimuli at two intensities, three frequencies, and five presentation periods. The experiment was conducted on 20 right-handed adult males, and a subjective evaluation was performed using a questionnaire. Regression analysis was performed to observe the parameters affecting cognitive characteristics according to changes in intensity, frequency, and stimulation duration. The regression analysis results showed that the cognitive characteristics affected by changes in intensity, frequency, and stimulation duration were "heavy", "bold", "thick", and "light". The cognitive characteristics affected by two-variable combinations were "deep", "clear", "vibrating", "dense", "numb", "blunt", "shallow", "fuzzy", and "soft". Cognitive characteristics affected by either intensity, frequency, or stimulation duration were "fast", "pungent", "skinny", "thin", "slow", "ticklish", "tingling", "prickling", "tap", and "rugged". By observing the cognitive characteristics that can be induced by the combination of intensity, frequency, and stimulation duration, we confirmed that in addition to intensity and frequency, the stimulation duration is an important factor that influences the induction of various cognitive characteristics. The results presented in the study can be used to enhance the utility of haptic surfaces for extended reality applications.
Collapse
Affiliation(s)
- Mi-Hyun Choi
- Biomedical Engineering, Research Institute of Biomedical Engineering, School of ICT Convergence Engineering, College of Science & Technology, Konkuk University, Chungju 27478, Republic of Korea
| | - Kyu-Beom Kim
- Biomedical Engineering, Research Institute of Biomedical Engineering, School of ICT Convergence Engineering, College of Science & Technology, Konkuk University, Chungju 27478, Republic of Korea
| | - Ye-Jin Kim
- Biomedical Engineering, Research Institute of Biomedical Engineering, School of ICT Convergence Engineering, College of Science & Technology, Konkuk University, Chungju 27478, Republic of Korea
| | - Ji-Su Kim
- Biomedical Engineering, Research Institute of Biomedical Engineering, School of ICT Convergence Engineering, College of Science & Technology, Konkuk University, Chungju 27478, Republic of Korea
| | - Hyung-Sik Kim
- Department of Mechatronics Engineering, School of ICT Convergence Engineering, College of Science & Technology, Konkuk University, Chungju 27478, Republic of Korea
| | - Soon-Cheol Chung
- Biomedical Engineering, Research Institute of Biomedical Engineering, School of ICT Convergence Engineering, College of Science & Technology, Konkuk University, Chungju 27478, Republic of Korea
| |
Collapse
|
3
|
Pardo LA, Markovic M, Schilling AF, Wilke MA, Ernst J. Vibrotactile mapping of the upper extremity: Absolute perceived intensity is location-dependent; perception of relative changes is not. Front Neurosci 2022; 16:958415. [PMID: 36389225 PMCID: PMC9650933 DOI: 10.3389/fnins.2022.958415] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Accepted: 10/07/2022] [Indexed: 11/29/2022] Open
Abstract
Vibrotactile sensation is an essential part of the sense of touch. In this study, the localized vibrotactile sensation of the arm-shoulder region was quantified in 10 able-bodied subjects. For this analysis, the six relevant dermatomes (C3-T2) and three segments—the lower arm, the upper arm, and the shoulder region were studied. For psychometric evaluation, tasks resulting in the quantification of sensation threshold, just noticeable difference, Weber fraction, and perception of dynamically changing vibrotactile stimuli were performed. We found that healthy subjects could reliably detect vibration in all tested regions at low amplitude (2–6% of the maximal amplitude of commonly used vibrotactors). The detection threshold was significantly lower in the lower arm than that in the shoulder, as well as ventral in comparison with the dorsal. There were no significant differences in Weber fraction (20%) detectable between the studied locations. A compensatory tracking task resulted in a significantly higher average rectified error in the shoulder than that in the upper arm, while delay and correlation coefficient showed no difference between the regions. Here, we presented a conclusive map of the vibrotactile sense of the healthy upper limb. These data give an overview of the sensory bandwidth that can be achieved with vibrotactile stimulation at the arm and may help in the design of vibrotactile feedback interfaces (displays) for the hand/arm/shoulder-region.
Collapse
Affiliation(s)
- Luis A. Pardo
- Department of Trauma Surgery, Orthopaedics and Plastic Surgery, University Medical Center Göttingen, Göttingen, Germany
- *Correspondence: Luis A. Pardo Jr.
| | - Marko Markovic
- Department of Trauma Surgery, Orthopaedics and Plastic Surgery, University Medical Center Göttingen, Göttingen, Germany
| | - Arndt F. Schilling
- Department of Trauma Surgery, Orthopaedics and Plastic Surgery, University Medical Center Göttingen, Göttingen, Germany
| | - Meike Annika Wilke
- Faculty of Life Sciences, Hamburg University of Applied Sciences (HAW), Hamburg, Germany
| | - Jennifer Ernst
- Department of Trauma Surgery, Orthopaedics and Plastic Surgery, University Medical Center Göttingen, Göttingen, Germany
- Department of Trauma Surgery, Medical School Hannover, Hanover, Germany
| |
Collapse
|
4
|
Nataletti S, Leo F, Dideriksen J, Brayda L, Dosen S. Combined spatial and frequency encoding for electrotactile feedback of myoelectric signals. Exp Brain Res 2022; 240:2285-2298. [PMID: 35879359 PMCID: PMC9458587 DOI: 10.1007/s00221-022-06409-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Accepted: 06/28/2022] [Indexed: 11/30/2022]
Abstract
Electrotactile stimulation has been commonly used in human–machine interfaces to provide feedback to the user, thereby closing the control loop and improving performance. The encoding approach, which defines the mapping of the feedback information into stimulation profiles, is a critical component of an electrotactile interface. Ideally, the encoding will provide a high-fidelity representation of the feedback variable while being easy to perceive and interpret by the subject. In the present study, we performed a closed-loop experiment wherein discrete and continuous coding schemes are combined to exploit the benefits of both techniques. Subjects performed a muscle activation-matching task relying solely on electrotactile feedback representing the generated myoelectric signal (EMG). In particular, we investigated the performance of two different coding schemes (spatial and spatial combined with frequency) at two feedback resolutions (low: 3 and high: 5 intervals). In both schemes, the stimulation electrodes were placed circumferentially around the upper arm. The magnitude of the normalized EMG was divided into intervals, and each electrode was associated with one interval. When the generated EMG entered one of the intervals, the associated electrode started stimulating. In the combined encoding, the additional frequency modulation of the active electrode also indicated the momentary magnitude of the signal within the interval. The results showed that combined coding decreased the undershooting rate, variability and absolute deviation when the resolution was low but not when the resolution was high, where it actually worsened the performance. This demonstrates that combined coding can improve the effectiveness of EMG feedback, but that this effect is limited by the intrinsic variability of myoelectric control. Our findings, therefore, provide important insights as well as elucidate limitations of the information encoding methods when using electrotactile stimulation to convey a feedback signal characterized by high variability (EMG biofeedback).
Collapse
Affiliation(s)
- Sara Nataletti
- Cognitive Architecture for Collaborative Technologies Unit, Istituto Italiano di Tecnologia (IIT), Genoa, Italy. .,Department of Informatics, Bioengineering Robotics, and System Engineering, University of Genoa, Genoa, Italy.
| | - Fabrizio Leo
- Cognitive Architecture for Collaborative Technologies Unit, Istituto Italiano di Tecnologia (IIT), Genoa, Italy
| | - Jakob Dideriksen
- Department of Health Science and Technology, Aalborg University, Ålborg, Denmark
| | - Luca Brayda
- Acoesis S.R.L., Genoa, Italy.,Robotics, Brain and Cognitive Science Unit, Istituto Italiano di Tecnologia (IIT), Genoa, Italy
| | - Strahinja Dosen
- Department of Health Science and Technology, Aalborg University, Ålborg, Denmark.
| |
Collapse
|
5
|
Guémann M, Halgand C, Bastier A, Lansade C, Borrini L, Lapeyre É, Cattaert D, de Rugy A. Sensory substitution of elbow proprioception to improve myoelectric control of upper limb prosthesis: experiment on healthy subjects and amputees. J Neuroeng Rehabil 2022; 19:59. [PMID: 35690860 PMCID: PMC9188052 DOI: 10.1186/s12984-022-01038-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2021] [Accepted: 05/31/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Current myoelectric prostheses lack proprioceptive information and rely on vision for their control. Sensory substitution is increasingly developed with non-invasive vibrotactile or electrotactile feedback, but most systems are designed for grasping or object discriminations, and few were tested for online control in amputees. The objective of this work was evaluate the effect of a novel vibrotactile feedback on the accuracy of myoelectric control of a virtual elbow by healthy subjects and participants with an upper-limb amputation at humeral level. METHODS Sixteen, healthy participants and 7 transhumeral amputees performed myoelectric control of a virtual arm under different feedback conditions: vision alone (VIS), vibration alone (VIB), vision plus vibration (VIS + VIB), or no feedback at all (NO). Reach accuracy was evaluated by angular errors during discrete as well as back and forth movements. Healthy participants' workloads were assessed with the NASA-TLX questionnaire, and feedback conditions were ranked according to preference at the end of the experiment. RESULTS Reach errors were higher in NO than in VIB, indicating that our vibrotactile feedback improved performance as compared to no feedback. Conditions VIS and VIS+VIB display similar levels of performance and produced lower errors than in VIB. Vision remains therefore critical to maintain good performance, which is not ameliorated nor deteriorated by the addition of vibrotactile feedback. The workload associated with VIB was higher than for VIS and VIS+VIB, which did not differ from each other. 62.5% of healthy subjects preferred the VIS+VIB condition, and ranked VIS and VIB second and third, respectively. CONCLUSION Our novel vibrotactile feedback improved myoelectric control of a virtual elbow as compared to no feedback. Although vision remained critical, the addition of vibrotactile feedback did not improve nor deteriorate the control and was preferred by participants. Longer training should improve performances with VIB alone and reduce the need of vision for close-loop prosthesis control.
Collapse
Affiliation(s)
- Matthieu Guémann
- HYBRID Team, INCIA, CNRS, UMR 5287, Bordeaux, France. .,Unité de Physiologie de l'Exercice et des Activités en Conditions Extrêmes,Département Environnements Opérationnels, Institut de Recherche Biomédicale des Armées, Brétigny, France.
| | | | | | | | - Léo Borrini
- Physical and Rehabilitation Medicine Department, Percy Military Hospital, Clamart, France
| | - Éric Lapeyre
- Physical and Rehabilitation Medicine Department, Percy Military Hospital, Clamart, France
| | | | - Aymar de Rugy
- HYBRID Team, INCIA, CNRS, UMR 5287, Bordeaux, France
| |
Collapse
|
6
|
Huang X, Liang S, Li Z, Lai CYY, Choi KS. EEG-based vibrotactile evoked brain-computer interfaces system: A systematic review. PLoS One 2022; 17:e0269001. [PMID: 35657949 PMCID: PMC9165854 DOI: 10.1371/journal.pone.0269001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Accepted: 05/12/2022] [Indexed: 11/18/2022] Open
Abstract
Recently, a novel electroencephalogram-based brain-computer interface (EVE-BCI) using the vibrotactile stimulus shows great potential for an alternative to other typical motor imagery and visual-based ones. (i) Objective: in this review, crucial aspects of EVE-BCI are extracted from the literature to summarize its key factors, investigate the synthetic evidence of feasibility, and generate recommendations for further studies. (ii) Method: five major databases were searched for relevant publications. Multiple key concepts of EVE-BCI, including data collection, stimulation paradigm, vibrotactile control, EEG signal processing, and reported performance, were derived from each eligible article. We then analyzed these concepts to reach our objective. (iii) Results: (a) seventy-nine studies are eligible for inclusion; (b) EEG data are mostly collected among healthy people with an embodiment of EEG cap in EVE-BCI development; (c) P300 and Steady-State Somatosensory Evoked Potential are the two most popular paradigms; (d) only locations of vibration are heavily explored by previous researchers, while other vibrating factors draw little interest. (e) temporal features of EEG signal are usually extracted and used as the input to linear predictive models for EVE-BCI setup; (f) subject-dependent and offline evaluations remain popular assessments of EVE-BCI performance; (g) accuracies of EVE-BCI are significantly higher than chance levels among different populations. (iv) Significance: we summarize trends and gaps in the current EVE-BCI by identifying influential factors. A comprehensive overview of EVE-BCI can be quickly gained by reading this review. We also provide recommendations for the EVE-BCI design and formulate a checklist for a clear presentation of the research work. They are useful references for researchers to develop a more sophisticated and practical EVE-BCI in future studies.
Collapse
Affiliation(s)
- Xiuyu Huang
- Centre for Smart Health, School of Nursing, The Hong Kong Polytechnic University, Hong Kong SAR, China
- * E-mail:
| | - Shuang Liang
- School of Geographic and Biologic Information, Nanjing University of Posts and Telecommunications, Nanjing, China
| | - Zengguang Li
- School of Computer Science and Technology, Nanjing Tech University, Nanjing, China
| | - Cynthia Yuen Yi Lai
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong SAR, China
| | - Kup-Sze Choi
- Centre for Smart Health, School of Nursing, The Hong Kong Polytechnic University, Hong Kong SAR, China
| |
Collapse
|
7
|
Olthof NA, Coppieters MW, Moseley GL, Sterling M, Chippindall DJ, Harvie DS. Modernising tactile acuity assessment; clinimetrics of semi-automated tests and effects of age, sex and anthropometry on performance. PeerJ 2021; 9:e12192. [PMID: 35070517 PMCID: PMC8759376 DOI: 10.7717/peerj.12192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Accepted: 08/31/2021] [Indexed: 11/24/2022] Open
Abstract
Background Reduced tactile acuity has been observed in several chronic pain conditions and has been proposed as a clinical indicator of somatosensory impairments related to the condition. As some interventions targeting these impairments have resulted in pain reduction, assessing tactile acuity may have significant clinical potential. While two-point discrimination threshold (TPDT) is a popular method of assessing tactile acuity, large measurement error has been observed (impeding responsiveness) and its validity has been questioned. The recently developed semi-automated ‘imprint Tactile Acuity Device’ (iTAD) may improve tactile acuity assessment, but clinimetric properties of its scores (accuracy score, response time and rate correct score) need further examination. Aims Experiment 1: To determine inter-rater reliability and measurement error of TPDT and iTAD assessments. Experiment 2: To determine internal consistencies and floor or ceiling effects of iTAD scores, and investigate effects of age, sex, and anthropometry on performance. Methods Experiment 1: To assess inter-rater reliability (ICC(2,1)) and measurement error (coefficient of variation (CoV)), three assessors each performed TPDT and iTAD assessments at the neck in forty healthy participants. Experiment 2: To assess internal consistency (ICC(2,k)) and floor or ceiling effects (skewness z-scores), one hundred healthy participants performed the iTAD’s localisation and orientation tests. Balanced for sex, participants were equally divided over five age brackets (18–30, 31–40, 41–50, 51–60 and 61–70). Age, sex, body mass index (BMI) and neck surface area were assessed to examine their direct (using multiple linear regression analysis) and indirect (using sequential mediation analysis) relationship with iTAD scores. Results Mean ICC(2,1) was moderate for TPDT (0.70) and moderate-to-good for the various iTAD scores (0.65–0.86). The CoV was 25.3% for TPDT and ranged from 6.1% to 16.5% for iTAD scores. Internal consistency was high for both iTAD accuracy scores (ICC(2,6) = 0.84; ICC(2,4) = 0.86). No overt floor or ceiling effects were detected (all skewness z-scores < 3.29). Accuracy scores were only directly related to age (decreasing with increasing age) and sex (higher for men). Discussion Although reliability was similar, iTAD scores demonstrated less measurement error than TPDT indicating a potential for better responsiveness to treatment effects. Further, unlike previously reported for TPDT, iTAD scores appeared independent of anthropometry, which simplifies interpretation. Additionally, the iTAD assesses multiple aspects of tactile processing which may provide a more comprehensive evaluation of tactile acuity. Taken together, the iTAD shows promise in measuring tactile acuity, but patient studies are needed to verify clinical relevance.
Collapse
Affiliation(s)
- Nick A. Olthof
- School of Health Sciences and Social Work, Griffith University, Brisbane and Gold Coast, QLD, Australia
- Menzies Health Institute Queensland, Griffith University, Brisbane and Gold Coast, QLD, Australia
| | - Michel W. Coppieters
- Menzies Health Institute Queensland, Griffith University, Brisbane and Gold Coast, QLD, Australia
- Amsterdam Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - G Lorimer Moseley
- IIMPACT in Health, University of South Australia, Kaurna Country, Adelaide, SA, Australia
| | - Michele Sterling
- RECOVER Injury Research Centre, The University of Queensland, Brisbane, QLD, Australia
- NHMRC Centre of Research Excellence in Road Traffic Injury Recovery, The University of Queensland, Brisbane, QLD, Australia
| | - Dylan J. Chippindall
- Menzies Health Institute Queensland, Griffith University, Brisbane and Gold Coast, QLD, Australia
| | - Daniel S. Harvie
- School of Health Sciences and Social Work, Griffith University, Brisbane and Gold Coast, QLD, Australia
- Menzies Health Institute Queensland, Griffith University, Brisbane and Gold Coast, QLD, Australia
- IIMPACT in Health, University of South Australia, Kaurna Country, Adelaide, SA, Australia
| |
Collapse
|
8
|
Mick S, Segas E, Dure L, Halgand C, Benois-Pineau J, Loeb GE, Cattaert D, de Rugy A. Shoulder kinematics plus contextual target information enable control of multiple distal joints of a simulated prosthetic arm and hand. J Neuroeng Rehabil 2021; 18:3. [PMID: 33407618 PMCID: PMC7789560 DOI: 10.1186/s12984-020-00793-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Accepted: 12/01/2020] [Indexed: 11/20/2022] Open
Abstract
Background Prosthetic restoration of reach and grasp function after a trans-humeral amputation requires control of multiple distal degrees of freedom in elbow, wrist and fingers. However, such a high level of amputation reduces the amount of available myoelectric and kinematic information from the residual limb. Methods To overcome these limits, we added contextual information about the target’s location and orientation such as can now be extracted from gaze tracking by computer vision tools. For the task of picking and placing a bottle in various positions and orientations in a 3D virtual scene, we trained artificial neural networks to predict postures of an intact subject’s elbow, forearm and wrist (4 degrees of freedom) either solely from shoulder kinematics or with additional knowledge of the movement goal. Subjects then performed the same tasks in the virtual scene with distal joints predicted from the context-aware network. Results Average movement times of 1.22s were only slightly longer than the naturally controlled movements (0.82 s). When using a kinematic-only network, movement times were much longer (2.31s) and compensatory movements from trunk and shoulder were much larger. Integrating contextual information also gave rise to motor synergies closer to natural joint coordination. Conclusions Although notable challenges remain before applying the proposed control scheme to a real-world prosthesis, our study shows that adding contextual information to command signals greatly improves prediction of distal joint angles for prosthetic control.
Collapse
Affiliation(s)
- Sébastien Mick
- Institut de Neurosciences Cognitives et Intégratives d'Aquitaine, UMR 5287, CNRS and Univ. Bordeaux, 146 rue Léo Saignat, 33076, Bordeaux, France.
| | - Effie Segas
- Institut de Neurosciences Cognitives et Intégratives d'Aquitaine, UMR 5287, CNRS and Univ. Bordeaux, 146 rue Léo Saignat, 33076, Bordeaux, France
| | - Lucas Dure
- Institut de Neurosciences Cognitives et Intégratives d'Aquitaine, UMR 5287, CNRS and Univ. Bordeaux, 146 rue Léo Saignat, 33076, Bordeaux, France
| | - Christophe Halgand
- Institut de Neurosciences Cognitives et Intégratives d'Aquitaine, UMR 5287, CNRS and Univ. Bordeaux, 146 rue Léo Saignat, 33076, Bordeaux, France
| | - Jenny Benois-Pineau
- Laboratoire Bordelais de Recherche en Informatique, UMR 5800, CNRS, Univ. Bordeaux and Bordeaux INP, 351 cours de la Libération, 33405, Talence, France
| | - Gerald E Loeb
- Department of Biomedical Engineering, Univ. Southern California, 1042 Downey Way, Los Angeles, CA, 90089, USA
| | - Daniel Cattaert
- Institut de Neurosciences Cognitives et Intégratives d'Aquitaine, UMR 5287, CNRS and Univ. Bordeaux, 146 rue Léo Saignat, 33076, Bordeaux, France
| | - Aymar de Rugy
- Institut de Neurosciences Cognitives et Intégratives d'Aquitaine, UMR 5287, CNRS and Univ. Bordeaux, 146 rue Léo Saignat, 33076, Bordeaux, France.,Centre for Sensorimotor Performance, School of Human Movement and Nutrition Sciences, Univ. Queensland, Blair Drive, Brisbane, QLD, 4059, Australia
| |
Collapse
|
9
|
Guemann M, Bouvier S, Halgand C, Paclet F, Borrini L, Ricard D, Lapeyre E, Cattaert D, de Rugy A. Correction to: Effect of vibration characteristics and vibror arrangement on the tactile perception of the upper arm in healthy subjects and upper limb amputees. J Neuroeng Rehabil 2020; 17:27. [PMID: 32075664 PMCID: PMC7031981 DOI: 10.1186/s12984-020-0656-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Affiliation(s)
- Matthieu Guemann
- Team HYBRID; INCIA laboratory, CNRS UMR 5287, University of Bordeaux, 146 rue Leo Saignat, 33076, Bordeaux, France.
| | | | - Christophe Halgand
- Team HYBRID; INCIA laboratory, CNRS UMR 5287, University of Bordeaux, 146 rue Leo Saignat, 33076, Bordeaux, France
| | - Florent Paclet
- Team HYBRID; INCIA laboratory, CNRS UMR 5287, University of Bordeaux, 146 rue Leo Saignat, 33076, Bordeaux, France
| | - Leo Borrini
- Departement of Rehabilitation at the Army instruction Hospital, 1 Rue du Lieutenant Raoul Batany, 92190, Clamart, France
| | - Damien Ricard
- Department of Neurology at the Army instruction Hospital, 1 Rue du Lieutenant Raoul Batany, 92190, Clamart, France
| | - Eric Lapeyre
- Departement of Rehabilitation at the Army instruction Hospital, 1 Rue du Lieutenant Raoul Batany, 92190, Clamart, France
| | - Daniel Cattaert
- Team HYBRID; INCIA laboratory, CNRS UMR 5287, University of Bordeaux, 146 rue Leo Saignat, 33076, Bordeaux, France
| | - Aymar de Rugy
- Team HYBRID; INCIA laboratory, CNRS UMR 5287, University of Bordeaux, 146 rue Leo Saignat, 33076, Bordeaux, France.,Centre for sensorimotor performance HMNS, University of Queensland, Brisbane, Australia
| |
Collapse
|