1
|
Tang S, Cheung JPY, Cheung PWH. Effectiveness of bracing to achieve curve regression in adolescent idiopathic scoliosis. Bone Joint J 2024; 106-B:286-292. [PMID: 38423123 DOI: 10.1302/0301-620x.106b3.bjj-2023-1105.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/02/2024]
Abstract
Aims To systematically evaluate whether bracing can effectively achieve curve regression in patients with adolescent idiopathic scoliosis (AIS), and to identify any predictors of curve regression after bracing. Methods Two independent reviewers performed a comprehensive literature search in PubMed, Ovid, Web of Science, Scopus, and Cochrane Library to obtain all published information about the effectiveness of bracing in achieving curve regression in AIS patients. Search terms included "brace treatment" or "bracing," "idiopathic scoliosis," and "curve regression" or "curve reduction." Inclusion criteria were studies recruiting patients with AIS undergoing brace treatment and one of the study outcomes must be curve regression or reduction, defined as > 5° reduction in coronal Cobb angle of a major curve upon bracing completion. Exclusion criteria were studies including non-AIS patients, studies not reporting p-value or confidence interval, animal studies, case reports, case series, and systematic reviews. The GRADE approach to assessing quality of evidence was used to evaluate each publication. Results After abstract and full-text screening, 205 out of 216 articles were excluded. The 11 included studies all reported occurrence of curve regression among AIS patients who were braced. Regression rate ranged from 16.7% to 100%. We found evidence that bracing is effective in achieving curve regression among compliant AIS patients eligible for bracing, i.e. curves of 25° to 40°. A similar effect was also found in patients with major curve sizes ranging from 40° to 60° when combined with scoliosis-specific exercises. There was also evidence showing that a low apical vertebral body height ratio, in-brace correction, smaller pre-brace Cobb angle, and daily pattern of brace-wear compliance predict curve regression after bracing. Conclusion Bracing provides a corrective effect on scoliotic curves of AIS patients to achieve curve regression, given there is high compliance rate and the incorporation of exercises.
Collapse
Affiliation(s)
- Shiyu Tang
- Department of Orthopaedics and Traumatology, The University of Hong Kong, Hong Kong SAR, China
| | - Jason P Y Cheung
- Department of Orthopaedics and Traumatology, The University of Hong Kong, Hong Kong SAR, China
| | - Prudence W H Cheung
- Department of Orthopaedics and Traumatology, The University of Hong Kong, Hong Kong SAR, China
| |
Collapse
|
2
|
Fregna G, Rossi Raccagni S, Negrini A, Zaina F, Negrini S. Personal and Clinical Determinants of Brace-Wearing Time in Adolescents with Idiopathic Scoliosis. SENSORS (BASEL, SWITZERLAND) 2023; 24:116. [PMID: 38202978 PMCID: PMC10780905 DOI: 10.3390/s24010116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Revised: 12/11/2023] [Accepted: 12/19/2023] [Indexed: 01/12/2024]
Abstract
Adolescent idiopathic scoliosis (AIS) is a three-dimensional spine and trunk deformity. Bracing is an effective treatment for medium-degree curves. Thermal sensors help monitor patients' adherence (compliance), a critical issue in bracing treatment. Some studies investigated adherence determinants but rarely through sensors or in highly adherent cohorts. We aimed to verify the influence of personal and clinical variables routinely registered by physicians on adherence to brace treatment in a large cohort of consecutive AIS patients from a highly adherent cohort. We performed a cross-sectional study of patients consecutively recruited in the last three years at a tertiary referral institute and treated with braces for one year. To ensure high adherence, for years, we have provided specific support to brace treatment through a series of cognitive-behavioural interventions for patients and parents. We used iButton thermal sensor systematic data collection to precisely analyse the real brace-wearing time. We included 514 adolescents, age 13.8 ± 1.6, with the worst scoliosis curve of 34.5 ± 10.3° Cobb. We found a 95% (95CI 60-101%) adherence to the brace prescription of 21.9 ± 1.7 h per day. Determinants included gender (91% vs. 84%; females vs. males) and age < 14 years (92% vs. 88%). Brace hours prescription, BMI, and all clinical variables (worst curve Cobb degrees, angle of trunk rotation, and TRACE index for aesthetics) did not influence adherence.
Collapse
Affiliation(s)
- Giulia Fregna
- ISICO (Italian Scientific Spine Institute), 20141 Milan, Italy; (S.R.R.); (A.N.); (F.Z.)
- Doctoral Program in Translational Neurosciences and Neurotechnologies, University of Ferrara, 44121 Ferrara, Italy
| | - Sara Rossi Raccagni
- ISICO (Italian Scientific Spine Institute), 20141 Milan, Italy; (S.R.R.); (A.N.); (F.Z.)
| | - Alessandra Negrini
- ISICO (Italian Scientific Spine Institute), 20141 Milan, Italy; (S.R.R.); (A.N.); (F.Z.)
| | - Fabio Zaina
- ISICO (Italian Scientific Spine Institute), 20141 Milan, Italy; (S.R.R.); (A.N.); (F.Z.)
| | - Stefano Negrini
- Department of Biomedical, Surgical and Dental Sciences, University “La Statale”, 20122 Milan, Italy;
- IRCCS Istituto Ortopedico Galeazzi, 20157 Milan, Italy
| |
Collapse
|
3
|
Liu S, Ho LY, Hassan Beygi B, Wong MS. Effectiveness of Orthotic Treatment on Clinical Outcomes of the Patients with Adolescent Idiopathic Scoliosis Under Different Wearing Compliance Levels: A Systematic Review. JBJS Rev 2023; 11:01874474-202310000-00010. [PMID: 38079521 DOI: 10.2106/jbjs.rvw.23.00110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
BACKGROUND Wearing spinal orthosis for 16 to 23 hours a day during the teenage years could be challenging and stressful for patients with adolescent idiopathic scoliosis (AIS). The investigation of clinical outcomes under various orthosis-wearing compliances can provide helpful insight into orthotic treatment dosage. This systematic review aims to investigate actual orthosis-wearing compliance and evaluate the effectiveness of orthotic treatment in controlling scoliotic curvature and preventing surgery for patients with AIS under various levels of orthosis-wearing compliance. METHODS A literature search of 7 electronic databases, namely PubMed, MEDLINE, Cochrane Library, Scopus, CINAHL Complete, Web of Science, and Embase, was conducted on May 19, 2023. Participant characteristics, orthotic treatment protocols, compliance information, outcome measures, and key findings were extracted. The Newcastle-Ottawa Scales were used to evaluate the quality of included cohort and case-control studies. RESULTS This study systematically reviewed 17 of 1,799 identified studies, including 1,981 subjects. The actual compliance was inconsistent and ranged from 7.0 to 18.8 hours daily. The proportion of compliant subjects in each study varied from 16.0% to 78.6% due to the heterogeneity of calculation period, measurement methods, and orthosis prescription time. Thirteen studies were investigated to determine the effectiveness of orthotic treatment in controlling curve deformity under different compliance groups, and 2 studies compared the compliance under different treatment outcomes. The rate of curve progression, defined as surpassing the measurement error threshold of 5° or 6° after orthotic treatment, varied from 1.8% to 91.7% across the studies. Ten studies defined the treatment failure, surgery, or surgery indication as Cobb angle progressing to a certain degree (e.g., 40°, 45°, or 50°) and reported failure/surgery/surgery indication rates ranging from 0.0% to 91.7% among different compliance level groups. CONCLUSION This review found that the actual compliance with orthotic treatment was generally lower than the prescribed wearing time and exhibited wide variation among different studies. The electronic compliance monitors show promise in regular orthotic treatment practice. More importantly, the group with higher and consistent compliance has significantly less curve progression and lower surgery or failure rate than the group with lower and inconsistent compliance. Further studies are proposed to investigate the minimal orthosis-wearing compliance in patients with AIS treated with different types of orthoses. LEVEL OF EVIDENCE Level III, Systematic Review. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Shan Liu
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| | | | | | | |
Collapse
|
4
|
Cordani C, Malisano L, Febbo F, Giranio G, Del Furia MJ, Donzelli S, Negrini S. Influence of Specific Interventions on Bracing Compliance in Adolescents with Idiopathic Scoliosis-A Systematic Review of Papers Including Sensors' Monitoring. SENSORS (BASEL, SWITZERLAND) 2023; 23:7660. [PMID: 37688117 PMCID: PMC10490632 DOI: 10.3390/s23177660] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 08/28/2023] [Accepted: 09/01/2023] [Indexed: 09/10/2023]
Abstract
Adolescent idiopathic scoliosis (AIS) is a common disease that, in many cases, can be conservatively treated through bracing. High adherence to brace prescription is fundamental to gaining the maximum benefit from this treatment approach. Wearable sensors are available that objectively monitor the brace-wearing time, but their use, combined with other interventions, is poorly investigated. The aims of the current review are as follows: (i) to summarize the real compliance with bracing reported by studies using sensors; (ii) to find out the real brace wearing rate through objective electronic monitoring; (iii) to verify if interventions made to increase adherence to bracing can be effective according to the published literature. We conducted a systematic review of the literature published on Medline, EMBASE, CINAHL, Scopus, CENTRAL, and Web of Science. We identified 466 articles and included examples articles, which had a low to good methodological quality. We found that compliance a greatly varied between 21.8 and 93.9% (weighted average: 58.8%), real brace wearing time varied between 5.7 and 21 h per day (weighted average 13.3), and specific interventions seemed to improve both outcomes, with compliance increasing from 58.5 to 66% and brace wearing increasing from 11.9 to 15.1 h per day. Two comparative studies showed positive effects of stand-alone counseling and information on the sensors' presence when added to counseling. Sensors proved to be useful tools for objectively and continuously monitoring adherence to therapy in everyday clinical practice. Specific interventions, like the use of sensors, counseling, education, and exercises, could increase compliance. However, further studies using high-quality designs should be conducted in this field.
Collapse
Affiliation(s)
- Claudio Cordani
- Department of Biomedical, Surgical and Dental Sciences, University “La Statale”, 20122 Milan, Italy; (C.C.); (S.N.)
- IRCCS Istituto Ortopedico Galeazzi, 20157 Milan, Italy;
| | - Lia Malisano
- Postgraduate School of Physical Therapy and Rehabilitative Medicine, University “La Statale”, 20122 Milan, Italy; (L.M.); (G.G.)
| | - Francesca Febbo
- ISICO (Italian Scientific Spine Institute), 20141 Milan, Italy;
| | - Giorgia Giranio
- Postgraduate School of Physical Therapy and Rehabilitative Medicine, University “La Statale”, 20122 Milan, Italy; (L.M.); (G.G.)
| | | | | | - Stefano Negrini
- Department of Biomedical, Surgical and Dental Sciences, University “La Statale”, 20122 Milan, Italy; (C.C.); (S.N.)
- IRCCS Istituto Ortopedico Galeazzi, 20157 Milan, Italy;
| |
Collapse
|
5
|
Guy A, Coulombe M, Labelle H, Rigo M, Wong MS, Beygi BH, Wynne J, Hresko MT, Ebermeyer E, Vedreine P, Liu XC, Thometz JG, Bissonnette B, Sapaly C, Barchi S, Aubin CÉ. Biomechanical Effects of Thoracolumbosacral Orthosis Design Features on 3D Correction in Adolescent Idiopathic Scoliosis: A Comprehensive Multicenter Study. Spine (Phila Pa 1976) 2022; 47:1103-1110. [PMID: 35275852 DOI: 10.1097/brs.0000000000004353] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Accepted: 03/03/2022] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN Multicenter numerical study. OBJECTIVE To biomechanically analyze and compare various passive correction features of braces, designed by several centers with diverse practices, for three-dimensional (3D) correction of adolescent idiopathic scoliosis. SUMMARY OF BACKGROUND DATA A wide variety of brace designs exist, but their biomechanical effectiveness is not clearly understood. Many studies have reported brace treatment correction potential with various degrees of control, making the objective comparison of correction mechanisms difficult. A Finite Element Model simulating the immediate in-brace corrective effects has been developed and allows to comprehensively assess the biomechanics of different brace designs. METHODS Expert clinical teams (one orthotist and one orthopedist) from six centers in five countries participated in the study. For six scoliosis cases with different curve types respecting SRS criteria, the teams designed two braces according to their treatment protocol. Finite Element Model simulations were performed to compute immediate in-brace 3D correction and skin-to-brace pressures. All braces were randomized and labeled according to 21 design features derived from Society on Scoliosis Orthopaedic and Rehabilitation Treatment proposed descriptors, including positioning of pressure points, orientation of push vectors, and sagittal design. Simulated in brace 3D corrections were compared for each design feature class using ANOVAs and linear regressions (significance P ≤ 0.05). RESULTS Seventy-two braces were tested, with significant variety in the design approaches. Pressure points at the apical vertebra level corrected the main thoracic curve better than more caudal locations. Braces with ventral support flattened the lumbar lordosis. Lateral and ventral skin-to-brace pressures were correlated with changes in thoracolumbar/lumbar Cobb and lumbar lordosis (r =- 0.53, r = - 0.54). Upper straps positioned above T10 corrected the main thoracic Cobb better than those placed lower. CONCLUSIONS The corrective features of various scoliosis braces were objectively compared in a systematic approach with minimal biases and variability in test parameters, providing a better biomechanical understanding of individual passive mechanisms' contribution to 3D correction.
Collapse
Affiliation(s)
- Aymeric Guy
- Polytechnique Montreal, Montreal, Quebec, Canada
- Sainte-Justine University Hospital Center, Montreal, Quebec, Canada
| | - Maxence Coulombe
- Sainte-Justine University Hospital Center, Montreal, Quebec, Canada
- Surgery Department, University of Montreal, Montreal, Quebec, Canada
| | - Hubert Labelle
- Sainte-Justine University Hospital Center, Montreal, Quebec, Canada
- Surgery Department, University of Montreal, Montreal, Quebec, Canada
| | - Manuel Rigo
- Institute Rigo Quera Salvá S.L.P. Scoliosis Rehabilitation Center, Barcelona, Spain
| | - Man-Sang Wong
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| | - Babak Hassan Beygi
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| | | | - Michael Timothy Hresko
- Department of Orthopaedic Surgery, Harvard Medical School, Boston, MA
- Boston Children's Hospital, Boston, MA
| | - Eric Ebermeyer
- LBM/Georges Charpak Human Biomechanics Institute, Arts et Métiers ParisTech, Paris, France
- Spine Unit, Bellevue University Hospital Center, Saint-Étienne, France
| | | | - Xue-Cheng Liu
- Department of Orthopedic Surgery, Children's Hospital of Wisconsin, Medical College of Wisconsin; Milwaukee, WI
| | - John G Thometz
- Department of Orthopedic Surgery, Children's Hospital of Wisconsin, Medical College of Wisconsin; Milwaukee, WI
| | | | | | - Soraya Barchi
- Sainte-Justine University Hospital Center, Montreal, Quebec, Canada
| | | |
Collapse
|
6
|
Oakley PA, Betz JW, Harrison DE, Siskin LA, Hirsh DW. Radiophobia Overreaction: College of Chiropractors of British Columbia Revoke Full X-Ray Rights Based on Flawed Study and Radiation Fear-Mongering. Dose Response 2021; 19:15593258211033142. [PMID: 34421439 PMCID: PMC8375354 DOI: 10.1177/15593258211033142] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Revised: 06/17/2021] [Accepted: 06/22/2021] [Indexed: 01/11/2023] Open
Abstract
Fears over radiation have created irrational pressures to dissuade radiography use within chiropractic. Recently, the regulatory body for chiropractors practicing in British Columbia, Canada, the College of Chiropractors of British Columbia (CCBC), contracted Pierre Côté to review the clinical use of X-rays within the chiropractic profession. A "rapid review" was performed and published quickly and included only 9 papers, the most recent dating from 2005; they concluded, "Given the inherent risks of radiation, we recommend that chiropractors do not use radiographs for the routine and repeat evaluation of the structure and function of the spine." The CCBC then launched an immediate review of the use of X-rays by chiropractors in their jurisdiction. Member and public opinion were gathered but not presented to their members. On February 4, 2021, the College announced amendments to their Professional Conduct Handbook that revoked X-ray rights for routine/repeat assessment and management of patients with spine disorders. Here, we highlight current and historical evidence that substantiates that X-rays are not a public health threat. We also point out critical and insurmountable flaws in the single paper used to support irrational and unscientific policy that discriminates against chiropractors who practice certain forms of evidence-based X-ray-guided methods.
Collapse
Affiliation(s)
| | | | | | | | | | - International Chiropractors Association Rapid Response Research Review Subcommittee
- Private Practice, Newmarket, ON, Canada
- Private Practice, Boise, ID, USA
- CBP NonProfit, Inc, Eagle, ID, USA
- Private Practice, Green Brook, NJ, USA
- Private Practice, Laurel, MD, USA
| |
Collapse
|
7
|
Costa L, Schlosser TPC, Jimale H, Homans JF, Kruyt MC, Castelein RM. The Effectiveness of Different Concepts of Bracing in Adolescent Idiopathic Scoliosis (AIS): A Systematic Review and Meta-Analysis. J Clin Med 2021; 10:2145. [PMID: 34063540 PMCID: PMC8156678 DOI: 10.3390/jcm10102145] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Accepted: 05/12/2021] [Indexed: 11/17/2022] Open
Abstract
Brace treatment is the most common noninvasive treatment in adolescent idiopathic scoliosis (AIS); however it is currently not fully known whether there is a difference in effectiveness between brace types/concepts. All studies on brace treatment for AIS were searched for in PubMed and EMBASE up to January 2021. Articles that did not report on maturity of the study population were excluded. Critical appraisal was performed using the Methodological Index for Non-Randomized Studies tool (MINORS). Brace concepts were distinguished in prescribed wearing time and rigidity of the brace: full-time, part-time, and night-time, rigid braces and soft braces. In the meta-analysis, success was defined as ≤5° curve progression during follow-up. Of the 33 selected studies, 11 papers showed high risk of bias. The rigid full-time brace had on average a success rate of 73.2% (95% CI 61-86%), night-time of 78.7% (72-85%), soft braces of 62.4% (55-70%), observation only of 50% (44-56%). There was insufficient evidence on part-time wear for the meta-analysis. The majority of brace studies have significant risk of bias. No significant difference in outcome between the night-time or full-time concepts could be identified. Soft braces have a lower success rate compared to rigid braces. Bracing for scoliosis in Risser 0-2 and 0-3 stage of maturation appeared most effective.
Collapse
Affiliation(s)
| | | | | | | | | | - René M. Castelein
- Department of Orthopaedic Surgery, University Medical Center Utrecht, 3508 GA Utrecht, The Netherlands; (L.C.); (T.P.C.S.); (H.J.); (J.F.H.); (M.C.K.)
| |
Collapse
|
8
|
Zhu C, Wu Q, Xiao B, Wang J, Luo C, Yu Q, Liu L, Song Y. A compliance real-time monitoring system for the management of the brace usage in adolescent idiopathic scoliosis patients: a pilot study. BMC Musculoskelet Disord 2021; 22:152. [PMID: 33546648 PMCID: PMC7866441 DOI: 10.1186/s12891-021-03976-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Accepted: 01/05/2021] [Indexed: 02/08/2023] Open
Abstract
Background Patient compliance is essential to the effectiveness of brace treatment for adolescent idiopathic scoliosis (AIS) patients. Subjective measurements like questionnaires and inquiries proved to be arguably inaccurate. Although some scholars have applied temperature/force monitors to measuring patient compliance objectively, few studies to date could monitor patient compliance in real time. The objective of this study is to describe and evaluate a compliance real-time monitoring system of the brace usage in AIS patients. Methods A compliance real-time monitoring system (specifically consisting of a compliance monitor, a WeChat Mini Program, a cloud-based storage system and a website backstage management system) was designed to manage the brace treatment. Thirty patients receiving brace treatment were enrolled. They were told to upload the data at least once a day. Clinicians downloaded the compliance data and communicated with the patients online based on their analysis of data at least once every 3 months. The measured force, quality compliance (measured force / baseline force), measured time, and quantity compliance (measured time/ prescribed time) were used to evaluate patient compliance. Patients were also asked to rate their satisfaction at the final follow-up. Results Twenty-eight patients were included in the final analysis. The mean baseline force was 1.23 ± 0.28 N. The mean measured force was 0.79 ± 0.29 N. The mean quality compliance was 64.8 ± 22.2%. The prescribed time of all patients was 23 h. The mean measured time was 14.1 ± 2.9 h. The mean quantity compliance was 61.3 ± 12.6%. Both the quality and quantity compliance during the first 3 months of treatment was significantly lower than the latter 3 months. In this study, 96.4% (27/28) patients were satisfied with the use of the monitoring system, among whom 21.4% (6/28) are very satisfied and 75.0% (21/28) are somewhat satisfied. Conclusions The compliance real-time monitoring system, without evaluating the clinical and radiographic outcomes for now, has already shown some feasibility and effectiveness for the management of the brace usage in AIS patients. This system, as a useful tool for online patient management and patient-clinician communication, would be potentially employed on a large scale in future for clinicians to improve the compliance and satisfaction of AIS patients who have received brace treatment.
Collapse
Affiliation(s)
- Ce Zhu
- Department of Orthopedics Surgery and Orthopedics Research Institute, West China Hospital, Sichuan University, No. 37 Guoxue Road, Chengdu, 610041, Sichuan, China.,Department of Spine Surgery, the Affiliated Hospital of Southwest Medical University, Luzhou, China
| | - Qiang Wu
- Department of Rehabilitation Medicine, West China Hospital, Sichuan University, Chengdu, China
| | - Bing Xiao
- Chengdu Spine Medical Technology Co., Ltd, Chengdu, China
| | - Juehan Wang
- Department of Orthopedics Surgery and Orthopedics Research Institute, West China Hospital, Sichuan University, No. 37 Guoxue Road, Chengdu, 610041, Sichuan, China
| | - Chao Luo
- Department of Orthopedics Surgery and Orthopedics Research Institute, West China Hospital, Sichuan University, No. 37 Guoxue Road, Chengdu, 610041, Sichuan, China
| | - Quan Yu
- SiChuan NeoSource BioTektronics Limited, Chengdu, China
| | - Limin Liu
- Department of Orthopedics Surgery and Orthopedics Research Institute, West China Hospital, Sichuan University, No. 37 Guoxue Road, Chengdu, 610041, Sichuan, China.
| | - Yueming Song
- Department of Orthopedics Surgery and Orthopedics Research Institute, West China Hospital, Sichuan University, No. 37 Guoxue Road, Chengdu, 610041, Sichuan, China.
| |
Collapse
|
9
|
Braces Designed Using CAD/CAM Combined or Not With Finite Element Modeling Lead to Effective Treatment and Quality of Life After 2 Years: A Randomized Controlled Trial. Spine (Phila Pa 1976) 2021; 46:9-16. [PMID: 32991513 DOI: 10.1097/brs.0000000000003705] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN Single-center prospective randomized controlled trial. OBJECTIVE The aim of this study was to assess the computer-aided design/manufacturing (CAD/CAM) brace design approach, with and without added finite element modeling (FEM) simulations, after 2 years in terms of clinical outcomes, 3D correction, compliance, and quality of life (QoL). SUMMARY OF BACKGROUND DATA .: Previous studies demonstrated that braces designed using a combination of CAD/CAM and FEM induced promising in-brace corrections, were lighter, thinner, and covered less trunk surface. Yet, their long-term impact on treatment quality has not been evaluated. METHODS One-hundred twenty adolescent idiopathic scoliosis patients were recruited following Scoliosis Research Society standardized criteria for brace treatment; 61 patients in the first subgroup (CAD) were given braces designed using CAD/CAM; 59 in the second subgroup (CAD-FEM) received braces additionally simulated and refined using a patient-specific FEM built from 3D reconstructions of the spine, rib cage and pelvis. Main thoracic (MT) and thoraco-lumbar/lumbar (TL/L) Cobb angles, sagittal curves, and apical rotations were compared at the initial visit and after 2 years. Patient compliance and QoL were tracked respectively by using embedded temperature sensors and SRS-22r questionnaires. RESULTS Forty-four patients with CAD-FEM braces and 50 with CAD braces completed the study. Average in-brace correction was 9° MT (8° CAD-FEM, 10° CAD, P = 0.054) and 12° TL/L (same for both subgroups, P = 0.91). Out-of-brace 2-year progression from initial deformity was <4° for all 3D measurements. Sixty-six percent of all cases (30 CAD-FEM, 35 CAD) met the ≤5° curve progression criterion, 83% (38 CAD-FEM, 43 CAD) stayed <45°, and 6% (5 CAD-FEM, 1 CAD) underwent fusion surgery. 3D correction, compliance, and QoL were not significantly different between both subgroups (P > 0.05). CONCLUSION After 2 years, patients with braces designed using CAD/CAM with/without FEM had satisfying clinical outcomes (compared to the BrAIST study), 3D corrections, compliance and QoL. A more comprehensive optimization of brace treatment remains to be accomplished. LEVEL OF EVIDENCE 2.
Collapse
|
10
|
Morningstar MW. Early intervention versus standard of care for mild idiopathic scoliosis: A case-controlled series based on SOSORT criteria evaluating the impact of a scoliosis activity suit. Clin Pract 2020; 10:1251. [PMID: 32477482 PMCID: PMC7246342 DOI: 10.4081/cp.2020.1251] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2020] [Accepted: 05/07/2020] [Indexed: 11/23/2022] Open
Abstract
In the present study, a group of adolescent patients diagnosed with mild adolescent idiopathic scoliosis wore a scoliosis activity suit instead of maintaining the recommended observation only strategy. These patients wore the scoliosis activity suit for up to 60 minutes twice daily while performing normal daily activities. These patients were followed through until end of growth. Their end of growth results were compared to a group of adolescent idiopathic scoliosis (AIS) patients who only participated in observation. The group who wore the scoliosis activity suit maintained their curve measurements through skeletal maturity, while the observation group saw their curves increase an average of 7 degrees. This study showed that a group of AIS patients were able to prevent their curves from progressing during growth, while those participating in an observation-only strategy saw their curves progress to beyond threshold where rigid brace prescription is recommended. These changes were statistically significant in intergroup comparison, as well as intragroup before and after comparison.
Collapse
|