1
|
Plaza D, Sroka Ł, Orzechowska K, Ślosarek K. Comparison of the dose distribution of the VMAT radiotherapy technique depending on the beam used: FFF-X10MV and FFF-X15MV. Rep Pract Oncol Radiother 2023; 28:654-660. [PMID: 38179296 PMCID: PMC10764046 DOI: 10.5603/rpor.97508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Accepted: 09/18/2023] [Indexed: 01/06/2024] Open
Abstract
Background The aim of the study was to answer the question of whether flattening filter (FF) and flattening filter-free (FFF) beams can be used alternately in the volumetric modulated arc therapy (VMAT) treatment technique, regardless of the size of the irradiated volume [small (S) or large (L) planning target volume (PTV)]. Materials and methods Two groups of patients were examined: a group with a S-PTV-laryngeal cancer and a group with a L-PTV - gynecological volume. For each patient, two treatment plans were made for beams (energies): FFF-X10MV and FF-X15MV. Then, a statistical analysis, nonparametric test, and independent groups were performed, comparing the beams' impact on the analyzed treatment plans. Results In the case of laryngeal irradiation (S-PTV), there are no statistically significant differences between the energy used and the assessed parameters of the plan. In the case of gynecological volume (L-PTV), only statistically significant differences were noted for the number of monitor units depending on the energy used. For a large irradiated volume (gynecological case), the use of FFF beams increases the number of monitor units by 39,4% in relation to the FF beam. Conclusions In the case of gynecological neoplasms, statistically significant differences were found in the number of monitor units. Therefore, in the case of irradiation of L-PTV, it is recommended that flattening-filtering beams are used due to the smaller number of monitors. In the case of S-PTV, no statistically significant differences were found between the types of beams used (FF or FFF) and the treatment plan parameters analyzed in the study.
Collapse
Affiliation(s)
- Dominika Plaza
- Radiotherapy Planning Department, Maria Skłodowska-Curie National Research Institute of Oncology, Gliwice Branch, Poland
| | - Łukasz Sroka
- Radiotherapy Planning Department, Maria Skłodowska-Curie National Research Institute of Oncology, Gliwice Branch, Poland
| | - Klaudia Orzechowska
- Radiotherapy Planning Department, Maria Skłodowska-Curie National Research Institute of Oncology, Gliwice Branch, Poland
| | - Krzysztof Ślosarek
- Radiotherapy Planning Department, Maria Skłodowska-Curie National Research Institute of Oncology, Gliwice Branch, Poland
| |
Collapse
|
2
|
Onal C, Bozca R, Oymak E, Guler OC. Comparison of helical and TomoDirect techniques with simultaneous integrated boost in early breast cancer patients. Rep Pract Oncol Radiother 2023; 28:541-550. [PMID: 37795226 PMCID: PMC10547420 DOI: 10.5603/rpor.a2023.0058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Accepted: 07/14/2023] [Indexed: 10/06/2023] Open
Abstract
Background The aim of the study was to perform dosimetric comparisons of helical (H) and TomoDirect (TD) plans for whole-breast irradiation (WBI) with simultaneous integrated boost (SIB) in early-stage breast cancer patients undergoing breast conserving surgery. Materials and methods Fifty patients, 25 with left-side and 25 with right-side tumors, were determined for a treatment planning system for a total dose of 50.4Gy in 1.8Gy per fraction to WBI, with a SIB of 2.3Gy per fraction delivered to the tumor bed. The planning target volume (PTV) doses and the conformity (CI) and homogeneity indices (HI) for PTVbreast and PTVboost, as well as organ-at-risk (OAR) doses and treatment times, were compared between the H and TD plans. Results All plans met the PTV coverage criteria for the H plan, except for mean V107 of PTVbreast for TD plan. The H plan yielded better homogeneity and conformity of dose distribution compared to the TD plan. The ipsilateral mean lung doses were not significantly different between the two plans. The TD plans is advantageous for mean doses to the heart, contralateral breast and lung, spinal cord, and esophagus than the H plans. In both the H and TD plans, the right-sided breast patients had lower heart dose parameters than the left-sided breast patients. The TD plan is superior to the H plan in sparing the contralateral breast and lung by decreasing low-dose volumes. Conclusions While the OAR dose advantages of TD are appealing, shorter treatment times or improved dose homogeneity and conformity for target volume may be advantageous for H plan.
Collapse
Affiliation(s)
- Cem Onal
- Division of Radiation Oncology, Iskenderun Gelisim Hospital, Hatay, Türkiye
- Department of Radiation Oncology, Baskent University Faculty of Medicine Adana Dr Turgut Noyan Research and Treatment Center, Adana, Türkiye
- Department of Radiation Oncology, Baskent University Faculty of Medicine, Ankara, Türkiye
| | - Recep Bozca
- Department of Radiation Oncology, Baskent University Faculty of Medicine Adana Dr Turgut Noyan Research and Treatment Center, Adana, Türkiye
| | - Ezgi Oymak
- Division of Radiation Oncology, Iskenderun Gelisim Hospital, Hatay, Türkiye
| | - Ozan Cem Guler
- Department of Radiation Oncology, Baskent University Faculty of Medicine Adana Dr Turgut Noyan Research and Treatment Center, Adana, Türkiye
| |
Collapse
|
3
|
Fogliata A, Parabicoli S, Paganini L, Reggiori G, Lobefalo F, Cozzi L, Franzese C, Franceschini D, Spoto R, Scorsetti M. Knowledge-based DVH estimation and optimization for breast VMAT plans with and without avoidance sectors. Radiat Oncol 2022; 17:200. [PMID: 36474297 PMCID: PMC9724419 DOI: 10.1186/s13014-022-02172-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Accepted: 11/30/2022] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND To analyze RapidPlan knowledge-based models for DVH estimation of organs at risk from breast cancer VMAT plans presenting arc sectors en-face to the breast with zero dose rate, feature imposed during the optimization phase (avoidance sectors AS). METHODS CT datasets of twenty left breast patients in deep-inspiration breath-hold were selected. Two VMAT plans, PartArc and AvoidArc, were manually generated with double arcs from ~ 300 to ~ 160°, with the second having an AS en-face to the breast to avoid contralateral breast and lung direct irradiation. Two RapidPlan models were generated from the two plan sets. The two models were evaluated in a closed loop to assess the model performance on plans where the AS were selected or not in the optimization. RESULTS The PartArc plans model estimated DVHs comparable with the original plans. The AvoidArc plans model estimated a DVH pattern with two steps for the contralateral structures when the plan does not contain the AS selected in the optimization phase. This feature produced mean doses of the contralateral breast, averaged over all patients, of 0.4 ± 0.1 Gy, 0.6 ± 0.2 Gy, and 1.1 ± 0.2 Gy for the AvoidArc plan, AvoidArc model estimation, RapidPlan generated plan, respectively. The same figures for the contralateral lung were 0.3 ± 0.1 Gy, 1.6 ± 0.6 Gy, and 1.2 ± 0.5 Gy. The reason was found in the possible incorrect information extracted from the model training plans due to the lack of knowledge about the AS. Conversely, in the case of plans with AS set in the optimization generated with the same AvoidArc model, the estimated and resulting DVHs were comparable. Whenever the AvoidArc model was used to generate DVH estimation for a plan with AS, while the optimization was made on the plan without the AS, the optimizer evidentiated the limitation of a minimum dose rate of 0.2 MU/°, resulting in an increased dose to the contralateral structures respect to the estimation. CONCLUSIONS The RapidPlan models for breast planning with VMAT can properly estimate organ at risk DVH. Attention has to be paid to the plan selection and usage for model training in the presence of avoidance sectors.
Collapse
Affiliation(s)
- Antonella Fogliata
- grid.417728.f0000 0004 1756 8807Radiotherapy and Radiosurgery Department, Humanitas Research Hospital IRCCS, Milan-Rozzano, Italy
| | - Sara Parabicoli
- grid.417728.f0000 0004 1756 8807Radiotherapy and Radiosurgery Department, Humanitas Research Hospital IRCCS, Milan-Rozzano, Italy
| | - Lucia Paganini
- grid.417728.f0000 0004 1756 8807Radiotherapy and Radiosurgery Department, Humanitas Research Hospital IRCCS, Milan-Rozzano, Italy
| | - Giacomo Reggiori
- grid.417728.f0000 0004 1756 8807Radiotherapy and Radiosurgery Department, Humanitas Research Hospital IRCCS, Milan-Rozzano, Italy
| | - Francesca Lobefalo
- grid.417728.f0000 0004 1756 8807Radiotherapy and Radiosurgery Department, Humanitas Research Hospital IRCCS, Milan-Rozzano, Italy
| | - Luca Cozzi
- grid.417728.f0000 0004 1756 8807Radiotherapy and Radiosurgery Department, Humanitas Research Hospital IRCCS, Milan-Rozzano, Italy ,grid.452490.eDepartment of Biomedical Sciences, Humanitas University, Milan-Pieve Emanuele, Italy
| | - Ciro Franzese
- grid.417728.f0000 0004 1756 8807Radiotherapy and Radiosurgery Department, Humanitas Research Hospital IRCCS, Milan-Rozzano, Italy ,grid.452490.eDepartment of Biomedical Sciences, Humanitas University, Milan-Pieve Emanuele, Italy
| | - Davide Franceschini
- grid.417728.f0000 0004 1756 8807Radiotherapy and Radiosurgery Department, Humanitas Research Hospital IRCCS, Milan-Rozzano, Italy
| | - Ruggero Spoto
- grid.417728.f0000 0004 1756 8807Radiotherapy and Radiosurgery Department, Humanitas Research Hospital IRCCS, Milan-Rozzano, Italy
| | - Marta Scorsetti
- grid.417728.f0000 0004 1756 8807Radiotherapy and Radiosurgery Department, Humanitas Research Hospital IRCCS, Milan-Rozzano, Italy ,grid.452490.eDepartment of Biomedical Sciences, Humanitas University, Milan-Pieve Emanuele, Italy
| |
Collapse
|
4
|
Zhang R, Xie Y, DiTusa C, Ohler R, Heins D, Bourgeois D, Guo B. Flattening Filter-Free Volumetric-Modulated Arc Radiotherapy for Left-Sided Whole-Breast, Partial-Breast, and Postmastectomy Irradiations. J Med Phys 2022; 47:166-172. [PMID: 36212208 PMCID: PMC9542989 DOI: 10.4103/jmp.jmp_146_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 03/23/2022] [Accepted: 04/09/2022] [Indexed: 11/20/2022] Open
Abstract
Purpose: Unflattened photon beams exhibit many benefits over traditional flattened beams for radiotherapy (RT), but comprehensive evaluations of dosimetric results and beam-on time using flattening filter-free (FFF) beams for all types of breast irradiations are still lacking. The purpose of this study was to investigate if FFF RT can maintain equal or better dose coverage than standard flattened-beam RT while reducing doses to organs at risk (OARs) and beam-on time for various types of breast cancer irradiations. Methods and Materials: FFF volumetric-modulated arc therapy (FFF-VMAT) and standard VMAT (STD-VMAT) treatment plans were created for 15 whole-breast irradiation (WBI) patients with 50 Gy/25 fractions, 13 partial-breast irradiation (PBI) patients with 38.5 Gy/10 fractions, and 9 postmastectomy irradiation (PMI) patients with 50 Gy/25 fractions. Planning target volume (PTV) coverage and dose to OARs were evaluated. Results: Both techniques produced clinically acceptable plans for all three types of irradiations. For WBI, FFF-VMAT plans exhibited similar PTV and OARs evaluation metrics as STD-VMAT. For PBI, FFF-VMAT plans showed significantly lower mean and maximum doses for ipsilateral and contralateral lungs, contralateral breast, and heart. For PMI, FFF-VMAT plans showed significantly lower mean dose and V5 for contralateral breast but significantly higher Dmean, Dmax, and V20 for ipsilateral lung and significantly higher Dmean, V22.5, and V30 for heart. FFF-VMAT techniques significantly reduced beam-on time than STD-VMAT for all cases. Conclusion: This work has shown that FFF beams are most beneficial for small-field irradiation such as PBI, and breast cancer patients could potentially benefit from the shortened beam-on time.
Collapse
|
5
|
Liu X, Jin F, Luo H, Zhang X, Guo M, Zhao X, Wu F, Guo Q. Clinical impact of the flattening filter free irradiation in fixed-field IMRT and VMAT for stage I–II nasal natural killer/T-cell lymphoma. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES 2021. [DOI: 10.1080/16878507.2021.1948759] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Affiliation(s)
- Xianfeng Liu
- Chongqing Key Laboratory of Translational Research for Cancer Metastasis and Individualized Treatment, Chongqing University Cancer Hospital, Chongqing, China
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, China
| | - Fu Jin
- Chongqing Key Laboratory of Translational Research for Cancer Metastasis and Individualized Treatment, Chongqing University Cancer Hospital, Chongqing, China
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, China
| | - Huanli Luo
- Chongqing Key Laboratory of Translational Research for Cancer Metastasis and Individualized Treatment, Chongqing University Cancer Hospital, Chongqing, China
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, China
| | - Xin Zhang
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, China
| | - Mingfang Guo
- Department of Gynecologic Oncology, Chongqing University Cancer Hospital, Chongqing, China
| | - Xiujuan Zhao
- Department of Gynecologic Oncology, Chongqing University Cancer Hospital, Chongqing, China
| | - Furong Wu
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, China
| | - Qishuai Guo
- Chongqing Key Laboratory of Translational Research for Cancer Metastasis and Individualized Treatment, Chongqing University Cancer Hospital, Chongqing, China
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing, China
| |
Collapse
|
6
|
McConnell K, Kirby N, Rasmussen K, Gutierrez AN, Papanikolaou N, Stanley D. Variability of Breast Surface Positioning Using an Active Breathing Coordinator for a Deep Inspiration Breath Hold Technique. Cureus 2021; 13:e15649. [PMID: 34306859 PMCID: PMC8279697 DOI: 10.7759/cureus.15649] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/10/2021] [Indexed: 12/14/2022] Open
Abstract
Purpose The Elekta Active Breathing CoordinatorTM (ABC) is used to control breathing and guide deep inspiration breath hold (DIBH). It has been shown to be accurate in lung cancers, but limited analysis has been performed on the spatial accuracy and reproducibility of the breast surface. The use of optical surface-image guidance for patient positioning has grown in popularity and is an alternative solution for breast DIBH. This study aims to evaluate the breast surface variability of an ABC-guided DIBH by using a three-dimensional (3D) surface imaging system to record surface position. Methods Ten participants were placed in the treatment position, and breathing baselines and inhalation volume threshold baselines were monitored and recorded using the ABC. Over 60 minutes, the breathing patterns were recorded by the ABC and CatalystHDTM (C-RAD, Uppsala, Sweden). For each breath hold, the valve of the ABC closed at the baseline inhalation threshold and a 3D surface image was acquired. For each point on the baseline breast surface, a 3D vector was calculated to the subsequent breath hold surface as well as a root mean square (RMS) vector magnitude for the entire surface. Results The average and standard deviation for the RMS difference between the baseline and subsequent evaluated images were 7.12 ± 2.70 mm. Conclusion This study shows that while the ABC-guided inhalation volume is kept constant, a non-negligible variability of the breast surface position exists. Special considerations should be used in clinical situations, where the positioning of the surface is considered more important than inhalation volume.
Collapse
Affiliation(s)
- Kristen McConnell
- Department of Radiation Oncology/Medical Physics, University of Alabama at Birmingham, Birmingham, USA
| | - Neil Kirby
- Department of Radiation Oncology, University of Texas Health Science Center at San Antonio, San Antonio, USA
| | - Karl Rasmussen
- Department of Radiation Oncology, University of Texas Health Science Center at San Antonio, San Antonio, USA
| | | | - Nikos Papanikolaou
- Department of Radiation Oncology, University of Texas Health Science Center at San Antonio, San Antonio, USA
| | - Dennis Stanley
- Department of Radiation Oncology, University of Alabama at Birmingham, Birmingham, USA
| |
Collapse
|
7
|
Effects of flattening filter (FF) and flattening filter-free (FFF) beams on small-field and large-field dose distribution using the VMAT treatment plan. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING 2021. [DOI: 10.2478/pjmpe-2021-0016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Abstract
Introduction: The aim of the study was to evaluate the influence of flattening filter (FF) and flattening filter-free (FFF) beams on small-field and large-field dose distribution using the VMAT treatment plan.
Material and methods: Dose distribution calculations were performed for the VMAT technique in two locations: the larynx (small irradiation field; average 30.1 cm2) and gynecology (large irradiation field; average 173.1 cm2) using X-6MV flattening filter (FF) and flattening filter-free (FFF) beams. The following values were compared: the number of monitor units, minimum doses, average doses in PTV and maximum average doses in OaR (spinal cord – in larynx radiotherapy, bladder and rectum - in gynecological radiotherapy) and RPI (Radiation Planning Index) coefficient.
Results and Discussion: The performed statistical tests indicate that there is a significant difference (p <0.05) between the number of monitor units in the irradiation of large (gynecological) fields between the FF and FFF beams. The dose distributions show no statistically significant differences between the flattening filter and flattening-free filter beams (regardless of the field size).
Conclusions: Due to the smaller number of monitor units, it is recommended to use flattening filter beams (FF) for large-field radiotherapy.
Collapse
|
8
|
Onal C, Efe E, Guler OC, Yildirim BA. Dosimetric Comparison of Sequential Versus Simultaneous-integrated Boost in Early-stage Breast Cancer Patients Treated With Breast-conserving Surgery. In Vivo 2020; 33:2181-2189. [PMID: 31662554 DOI: 10.21873/invivo.11720] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2019] [Revised: 08/15/2019] [Accepted: 08/16/2019] [Indexed: 12/19/2022]
Abstract
BACKGROUND/AIM To compare simultaneous-integrated boost (SIB) versus sequential-boost (SB) delivered in the context of whole-breast irradiation (WBI) via volumetric-modulated arc therapy (VMAT) and helical-tomotherapy (HT). MATERIALS AND METHODS Planning target-volume (PTV) dosimetric parameters and organs at risk (OAR) were analyzed for SB plan (50 Gy plus 16 Gy boost) and SIB plan (50.4 Gy WBI and 64.4 Gy tumor bed boost) in VMAT and HT techniques. RESULTS Conformity and homogeneity for target-volume doses were better in HT plans compared to VMAT plans. There were no significant differences in ipsilateral lung doses between VMAT and HT plans for SB/SIB techniques, except for a significantly higher lung V5 value with VMAT-SB, and lung V13 value with HT-SIB technique. HT provided a statistically significant decrease in contralateral lung mean V5. CONCLUSION The SIB technique showed better target-volume dose distribution in both HT and VMAT plans, and better sparing heart in HT compared to the SB technique.
Collapse
Affiliation(s)
- Cem Onal
- Department of Radiation Oncology, Baskent University Faculty of Medicine, Adana, Turkey
| | - Esma Efe
- Department of Radiation Oncology, Baskent University Faculty of Medicine, Adana, Turkey
| | - Ozan C Guler
- Department of Radiation Oncology, Baskent University Faculty of Medicine, Adana, Turkey
| | - Berna A Yildirim
- Department of Radiation Oncology, Baskent University Faculty of Medicine, Adana, Turkey
| |
Collapse
|
9
|
Treutwein M, Steger F, Loeschel R, Koelbl O, Dobler B. The influence of radiotherapy techniques on the plan quality and on the risk of secondary tumors in patients with pituitary adenoma. BMC Cancer 2020; 20:88. [PMID: 32013920 PMCID: PMC6998093 DOI: 10.1186/s12885-020-6535-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2019] [Accepted: 01/13/2020] [Indexed: 12/20/2022] Open
Abstract
Background This planning study compares different radiotherapy techniques for patients with pituitary adenoma, including flatness filter free mode (FFF), concerning plan quality and secondary malignancies for potentially young patients. The flatness filter has been described as main source of photon scatter. Material and methods Eleven patients with pituitary adenoma were included. An Elekta Synergy™ linac was used in the treatment planning system Oncentra® and for the measurements. 3D plans, IMRT, and VMAT plans and non-coplanar varieties were considered. The plan quality was evaluated regarding homogeneity, conformity, delivery time and dose to the organs at risk. The secondary malignancy risk was calculated from dose volume data and from measured dose to the periphery using different models for carcinoma and sarcoma risk. Results The homogeneity and conformity were nearly unchanged with and without flattening filter, neither was the delivery time found substantively different. VMAT plans were more homogenous, conformal and faster in delivery than IMRT plans. The secondary cancer risk was reduced with FFF both in the treated region and in the periphery. VMAT plans resulted in a higher secondary brain cancer risk than IMRT plans, but the risk for secondary peripheral cancer was reduced. Secondary sarcoma risk plays a minor role. No advantage was found for non-coplanar techniques. The FFF delivery times were not shortened due to additional monitor units needed and technical limitations. The risk for secondary brain cancer seems to depend on the irradiated volume. Secondary sarcoma risk is much smaller than carcinoma risk in accordance to the results of the atomic bomb survivors. The reduction of the peripheral dose and resulting secondary malignancy risk for FFF is statistically significant. However, it is negligible in comparison to the risk in the treated region. Conclusion Treatments with FFF can reduce secondary malignancy risk while retaining similar quality as with flattening filter and should be preferred. VMAT plans show the best plan quality combined with lowest peripheral secondary malignancy risk, but highest level of second brain cancer risk. Taking this into account VMAT FFF seems the most advantageous technique for the treatment of pituitary adenomas with the given equipment.
Collapse
Affiliation(s)
- Marius Treutwein
- Department for radiotherapy, Regensburg University Medical Center, Regensburg, Germany.
| | - Felix Steger
- Department for radiotherapy, Regensburg University Medical Center, Regensburg, Germany
| | - Rainer Loeschel
- Faculty of computer science and mathematics, Ostbayerische Technische Hochschule, Regensburg, Germany
| | - Oliver Koelbl
- Department for radiotherapy, Regensburg University Medical Center, Regensburg, Germany
| | - Barbara Dobler
- Department for radiotherapy, Regensburg University Medical Center, Regensburg, Germany
| |
Collapse
|
10
|
Cozzi L, Lohr F, Fogliata A, Franceschini D, De Rose F, Filippi AR, Guidi G, Vanoni V, Scorsetti M. Critical appraisal of the role of volumetric modulated arc therapy in the radiation therapy management of breast cancer. Radiat Oncol 2017; 12:200. [PMID: 29258539 PMCID: PMC5735809 DOI: 10.1186/s13014-017-0935-4] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2017] [Accepted: 12/05/2017] [Indexed: 02/06/2023] Open
Abstract
Background The aim of this review is the critical appraisal of the current use of volumetric modulated arc therapy for the radiation therapy management of breast cancer. Both clinical and treatment planning studies were investigated. Material and methods A Pubmed/MEDLINE search of the National Library of Medicine was performed to identify VMAT and breast related articles. After a first order rejection of the irrelevant findings, the remaining articles were grouped according to two main categories: clinical vs. planning studies and to some sub-categories (pointing to significant technical features). Main areas of application, dosimetric and clinical findings as well as areas of innovations were defined. Results A total of 131 articles were identified and of these, 67 passed a first order selection. Six studies reported clinical results while 61 treatment dealed with treatment planning investigations. Among the innovation lines, the use of high intensity photon beams (flattening filter free), altered fractionation schemes (simultaneous integrated boost, accelerated partial breast irradiation, single fraction), prone positioning and modification of standard VMAT (use of dynamic trajectories or hybrid VMAT methods) resulted among the main relevant fields of interest. Approximately 10% of the publications reported upon respiratory gating in conjunction with VMAT. Conclusions The role of VMAT in the radiation treatment of breast cancer seems to be consolidated in the in-silico arena while still limited evidence and only one phase II trial appeared in literature from the clinical viewpoint. More clinical reports are needed to fully proove the expected dosimetric benefits demonstrated in the planning investigations.
Collapse
Affiliation(s)
- Luca Cozzi
- Radiotherapy and Radiosurgery Department, Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano-Milan, Italy. .,Department of Biomedical Sciences, Humanitas University, Rozzano, Italy.
| | - Frank Lohr
- Radiation Oncology Department, Ospedaliero-Universitaria, Modena, Italy
| | - Antonella Fogliata
- Radiotherapy and Radiosurgery Department, Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano-Milan, Italy
| | - Davide Franceschini
- Radiotherapy and Radiosurgery Department, Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano-Milan, Italy
| | - Fiorenza De Rose
- Radiotherapy and Radiosurgery Department, Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano-Milan, Italy
| | - A R Filippi
- Department of Radiation Oncology, Osp. S. Luigi Gonzaga University Hospital, Torino, Italy
| | - Gabriele Guidi
- Medical Physics Department, Az. Ospedaliero-Universitaria, Modena, Italy
| | | | - Marta Scorsetti
- Radiotherapy and Radiosurgery Department, Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano-Milan, Italy.,Department of Biomedical Sciences, Humanitas University, Rozzano, Italy
| |
Collapse
|
11
|
Dobler B, Obermeier T, Hautmann MG, Khemissi A, Koelbl O. Simultaneous integrated boost therapy of carcinoma of the hypopharynx/larynx with and without flattening filter - a treatment planning and dosimetry study. Radiat Oncol 2017; 12:114. [PMID: 28679448 PMCID: PMC5499025 DOI: 10.1186/s13014-017-0850-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2016] [Accepted: 06/28/2017] [Indexed: 01/26/2023] Open
Abstract
Background The aim of this study was to investigate if the flattening filter free (FFF) irradiation mode of a linear accelerator (linac) is advantageous as compared to the flat beam (FF) irradiation mode in intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) for carcinoma of the hypopharynx / larynx. Methods Four treatment plans were created for each of 10 patients for an Elekta Synergy linac with Agility collimating device, a dual arc VMAT and a nine field step and shoot IMRT each with and without flattening filter. Plan quality was compared considering target coverage and dose to the organs at risk. All plans were verified by a 2D–ionization-chamber-array and delivery times were compared. Peripheral point doses were determined as a measure of second cancer risk. The Wilcoxon test was used for statistical analysis with a significance level of 0.05. Results Plan quality was similar for all four treatment plans without statistically significant differences of clinical relevance. The clinical goals were met in all plans for the PTV-SIB (V95% > 95%), the spinal cord (D1ccm < 45 Gy) and the brain stem (D1ccm < 48 Gy). For the parotids, the goal of D50% < 30 Gy was met in 70% and 60% of the plans for the left and right parotid respectively, and the V95% of the SIB reached an average of 94%. Delivery times were similar for FF and FFF and significantly decreased by around 70% for VMAT as compared to IMRT. Peripheral doses were significantly reduced by 18% in FFF mode as compared to FF and by 26% for VMAT as compared to IMRT. Lowest peripheral doses were found for VMAT FFF, followed by VMAT FF. Conclusions The FFF mode of a linear accelerator is advantageous for the treatment of hypopharynx/larynx carcinoma only with respect to reduction of second cancer induction in peripheral organs for the combination of Elekta Synergy linacs and Oncentra® External Beam v4.5 treatment planning system. This might be of interest in a therapy with curative intent.
Collapse
Affiliation(s)
- Barbara Dobler
- Department of Radiotherapy, Regensburg University Medical Center, Regensburg, Germany.
| | - Tina Obermeier
- Department of Radiotherapy, Regensburg University Medical Center, Regensburg, Germany
| | - Matthias G Hautmann
- Department of Radiotherapy, Regensburg University Medical Center, Regensburg, Germany
| | - Amine Khemissi
- Department of Radiotherapy, Regensburg University Medical Center, Regensburg, Germany
| | - Oliver Koelbl
- Department of Radiotherapy, Regensburg University Medical Center, Regensburg, Germany
| |
Collapse
|
12
|
Tamilarasu S, Saminathan M, Sharma SK, P A, Dewan A. Treatment Planning With Unflattened as Compared to Flattened
Beams for Bilateral Carcinoma of the Breast. Asian Pac J Cancer Prev 2017; 18:1377-1381. [PMID: 28612590 PMCID: PMC5555550 DOI: 10.22034/apjcp.2017.18.5.1377] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
Aim: To evaluate the plan quality of 6MV unflattened (UFB) and flattened beam (FB) photon energy using AAA dose calculation algorithms for volumetric arc therapy. Materials and Methods: Plans were generated for bilateral carcinoma of breast and the dose prescribed was 50.4Gy in 28 fractions. Two different plans were made for each patient using 6MV FB and 6MV UFB. Dose calculations were performed on an AAA dose calculation algorithm. Plans were generated on Eclipse TPS and were capable of being delivered with a true beam STx linear accelerator. The homogeneity index (HI), conformity index (CI), normal tissue integral dose (NTID), and effect of low dose volume on normal tissue and monitor units (MU) were noted. Results: All the plans were clinically acceptable. The HI and CI of 6MV UF rapid arc (RA) plans were higher than with the 6MV FB plan (1.16±0.05 and 0.12±0.00 respectively). There was no appreciable difference observed in Organ at risk (OAR) doses. The mean NTID and low dose volume were significantly low with 6MV RA UFB as compared to FB. 6MV RA UFB required a 35% higher MU than with the 6MV RA plan (p<0.05). Conclusion: RA plans generated with UFB on Eclipse TPS achieved target volume coverage and preserved OAR’s essentially similar to 6MV RA FB plans. However RA plans generated in Varian Eclipse of UFB were superior with respect to mean NTID and low dose volumes in normal tissue.
Collapse
Affiliation(s)
- Suresh Tamilarasu
- Department of Radiotherapy, Rajiv Gandhi Cancer Institute and Research Centre, Rohini, New Delhi, India
| | | | | | | | | |
Collapse
|