1
|
Seok J, Kim H, Han MC, Kim J, Park K, Cho H, Yoo D, Kim JS. Development of a new VMAT QA framework for Mobius3D using control-point specific EPID images. Front Oncol 2024; 14:1478118. [PMID: 39697228 PMCID: PMC11652483 DOI: 10.3389/fonc.2024.1478118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2024] [Accepted: 11/12/2024] [Indexed: 12/20/2024] Open
Abstract
Purpose This study presents novel quality assurance (QA) approach for volumetric modulated arc therapy (VMAT) that leverages frame-by-frame electronic portal imaging device (EPID) images integrated into Mobius3D for accurate three-dimensional dose calculations. Methods Sequential EPID images for VMAT plans were acquired every 0.4-second by iView system and processed through iterative deconvolution to mitigate blurring from photon scattering. Deconvolved images were binarized to define multi-leaf collimator (MLC) positions. Pre-acquired box fluences determined optimal threshold for binarization and adjusted for detector shift depending on gantry and collimator angles. Sequential EPID images were re-scaled using pixel scaling factor (PSF) and converted to monitor unit (MU) proportional values. Generated EPID-based log file, including control-point specific MLC and monitor units (MU) information, were analyzed in Mobius3D for Gamma passing rate (GPR) of VMAT plans from 18 patients. Plan complexity indices were calculated and correlated with GPR. Results Clinically appropriate threshold was defined to be 20000 that can extract accurate MLC data from the deconvolved binarized EPID images. Positional deviations due to gantry and collimator rotations were observed to be up to 4.5 pixels. Recalibrated EPID pixel values showed linearity with MU regardless of changes in dose rate. Consequently, average GPR for 18 patients evaluated using Mobius3D reached 95.2% ± 3.7%%, based on 3% dose difference and 3mm distance-to-agreement criterion. It was found that two plan complexity indices showed statistically significant correlation with GPR. Conclusion This study successfully implemented novel measurement-based VMAT QA framework based on control-point specific EPID, based upon accurate MLC and MU data at each frame.
Collapse
Affiliation(s)
- JaeHyun Seok
- Department of Integrative Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea
- Medical Physics and Biomedical Engineering Lab (MPBEL), Yonsei University College of Medicine, Seoul, Republic of Korea
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Hojin Kim
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Min Cheol Han
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Jihun Kim
- Department of Radiation Oncology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Kwangwoo Park
- Department of Radiation Oncology, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, Republic of Korea
| | - Hyeonjeong Cho
- Medical Physics and Biomedical Engineering Lab (MPBEL), Yonsei University College of Medicine, Seoul, Republic of Korea
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
- Department of Biomedical Sciences, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Dohyeon Yoo
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Jin Sung Kim
- Medical Physics and Biomedical Engineering Lab (MPBEL), Yonsei University College of Medicine, Seoul, Republic of Korea
- Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea
- Oncosoft Inc., Seoul, Republic of Korea
| |
Collapse
|
2
|
Zhou Y, Liu Y, Chen M, Fang J, Xiao L, Huang S, Qi Z, Deng X, Zhang J, Peng Y. Commissioning and clinical evaluation of a novel high-resolution quality assurance digital detector array for SRS and SBRT. J Appl Clin Med Phys 2024; 25:e14258. [PMID: 38175960 PMCID: PMC11005972 DOI: 10.1002/acm2.14258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Revised: 12/03/2023] [Accepted: 12/18/2023] [Indexed: 01/06/2024] Open
Abstract
PURPOSE We aimed to perform the commissioning and clinical evaluation of myQA SRS detector array for patient-specific quality assurance (PSQA) of stereotactic radiosurgery (SRS)/ stereotactic body radiotherapy (SBRT) plans. METHODS To perform the commissioning of myQA SRS, its dose linearity, dose-rate dependence, angular dependence, and field-size dependence were investigated. Ten SBRT plans were selected for clinical evaluation: 1) Common clinical deviations based on the original SBRT plan (Plan0), including multileaf collimator (MLC) positioning deviation and treatment positioning deviation were introduced. 2) Compared the performance of the myQA SRS and a high-resolution EPID dosimetry system in PSQA measurement for the SBRT plans. Evaluation parameters include gamma passing rate (GPR) and distance-to-agreement (DTA) pass rate (DPR). RESULTS The dose linearity, angle dependence, and field-size dependence of myQA SRS system exhibit excellent performance. The myQA SRS is highly sensitive in the detection of MLC deviations. The GPR of (3%/1 mm) decreases from 90.4% of the original plan to 72.7%/62.9% with an MLC outward/inward deviation of 3 mm. Additionally, when the setup error deviates by 1 mm in the X, Y, and Z directions with the GPR of (3%/1 mm) decreasing by an average of -20.9%, -25.7%, and -24.7%, respectively, and DPR (1 mm) decreasing by an average of -33.7%, -32.9%, and -29.8%. Additionally, the myQA SRS has a slightly higher GPR than EPID for PSQA, However, the difference is not statistically significant with the GPR of (3%/1 mm) of (average 90.4%% vs. 90.1%, p = 0.414). CONCLUSION Dosimetry characteristics of the myQA SRS device meets the accuracy and sensitivity requirement of PSQA for SRS/SBRT treatment. The dose rate dependence should be adequately calibrated before its application and a more stringent GPR (3%/1 mm) evaluation criterion is suggested when it is used for SRS/SBRT QA.
Collapse
Affiliation(s)
- Yang Zhou
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for CancerSun Yat‐sen University Cancer CenterGuangzhouP. R. China
- Department of Radiation Oncology, Zhuzhou Hospital Affiliated to Xiangya School of MedicineCentral South UniversityZhuzhouP. R. China
| | - Yimei Liu
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for CancerSun Yat‐sen University Cancer CenterGuangzhouP. R. China
| | - Meining Chen
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for CancerSun Yat‐sen University Cancer CenterGuangzhouP. R. China
| | - Jianlan Fang
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for CancerSun Yat‐sen University Cancer CenterGuangzhouP. R. China
| | - Liangjie Xiao
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for CancerSun Yat‐sen University Cancer CenterGuangzhouP. R. China
| | - Shaomin Huang
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for CancerSun Yat‐sen University Cancer CenterGuangzhouP. R. China
| | - Zhenyu Qi
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for CancerSun Yat‐sen University Cancer CenterGuangzhouP. R. China
| | - Xiaowu Deng
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for CancerSun Yat‐sen University Cancer CenterGuangzhouP. R. China
| | - Jun Zhang
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for CancerSun Yat‐sen University Cancer CenterGuangzhouP. R. China
| | - Yinglin Peng
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for CancerSun Yat‐sen University Cancer CenterGuangzhouP. R. China
| |
Collapse
|
3
|
Zhang H, Zhang B, Lasio G, Chen S, Nasehi Tehrani J. Assessing quality assurance of multi-leaf collimator using the structural similarity index. J Appl Clin Med Phys 2024; 25:e14288. [PMID: 38345201 PMCID: PMC11005984 DOI: 10.1002/acm2.14288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 12/11/2023] [Accepted: 01/22/2024] [Indexed: 04/11/2024] Open
Abstract
PURPOSE This study aims to evaluate the viability of utilizing the Structural Similarity Index (SSI*) as an innovative imaging metric for quality assurance (QA) of the multi-leaf collimator (MLC). Additionally, we compared the results obtained through SSI* with those derived from a conventional Gamma index test for three types of Varian machines (Trilogy, Truebeam, and Edge) over a 12-week period of MLC QA in our clinic. METHOD To assess sensitivity to MLC positioning errors, we designed a 1 cm slit on the reference MLC, subsequently shifted by 0.5-5 mm on the target MLC. For evaluating sensitivity to output error, we irradiated five 25 cm × 25 cm open fields on the portal image with varying Monitor Units (MUs) of 96-100. We compared SSI* and Gamma index tests using three linear accelerator (LINAC) machines: Varian Trilogy, Truebeam, and Edge, with MLC leaf widths of 1, 0.5, and 0.25 mm. Weekly QA included VMAT and static field modes, with Picket fence test images acquired. Mechanical uncertainties related to the LINAC head, electronic portal imaging device (EPID), and MLC during gantry rotation and leaf motion were monitored. RESULTS The Gamma index test started detecting the MLC shift at a threshold of 4 mm, whereas the SSI* metric showed sensitivity to shifts as small as 2 mm. Moreover, the Gamma index test identified dose changes at 95MUs, indicating a 5% dose difference based on the distance to agreement (DTA)/dose difference (DD) criteria of 1 mm/3%. In contrast, the SSI* metric alerted to dose differences starting from 97MUs, corresponding to a 3% dose difference. The Gamma index test passed all measurements conducted on each machine. However, the SSI* metric rejected all measurements from the Edge and Trilogy machines and two from the Truebeam. CONCLUSIONS Our findings demonstrate that the SSI* exhibits greater sensitivity than the Gamma index test in detecting MLC positioning errors and dose changes between static and VMAT modes. The SSI* metric outperformed the Gamma index test regarding sensitivity across these parameters.
Collapse
Affiliation(s)
- Hong Zhang
- Departments of Radiation OncologyVanderbilt University Medical CenterNashvilleTennesseeUSA
| | - Baoshe Zhang
- Departments of Radiation OncologyMedical SchoolUniversity of MarylandBaltimoreMarylandUSA
| | - Giovanni Lasio
- Departments of Radiation OncologyMedical SchoolUniversity of MarylandBaltimoreMarylandUSA
| | - Shifeng Chen
- Departments of Radiation OncologyMedical SchoolUniversity of MarylandBaltimoreMarylandUSA
| | - Joubin Nasehi Tehrani
- Departments of Radiation OncologyMedical SchoolUniversity of MarylandBaltimoreMarylandUSA
| |
Collapse
|
4
|
Tan HQ, Lew KS, Wong YM, Chong WC, Koh CWY, Chua CGA, Yeap PL, Ang KW, Lee JCL, Park SY. Detecting outliers beyond tolerance limits derived from statistical process control in patient-specific quality assurance. J Appl Clin Med Phys 2024; 25:e14154. [PMID: 37683120 PMCID: PMC10860546 DOI: 10.1002/acm2.14154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 08/18/2023] [Accepted: 08/21/2023] [Indexed: 09/10/2023] Open
Abstract
BACKGROUND Tolerance limit is defined on pre-treatment patient specific quality assurance results to identify "out of the norm" dose discrepancy in plan. An out-of-tolerance plan during measurement can often cause treatment delays especially if replanning is required. In this study, we aim to develop an outlier detection model to identify out-of-tolerance plan early during treatment planning phase to mitigate the above-mentioned risks. METHODS Patient-specific quality assurance results with portal dosimetry for stereotactic body radiotherapy measured between January 2020 and December 2021 were used in this study. Data were divided into thorax and pelvis sites and gamma passing rates were recorded using 2%/2 mm, 2%/1 mm, and 1%/1 mm gamma criteria. Statistical process control method was used to determine six different site and criterion-specific tolerance and action limits. Using only the inliers identified with our determined tolerance limits, we trained three different outlier detection models using the plan complexity metrics extracted from each treatment field-robust covariance, isolation forest, and one class support vector machine. The hyperparameters were optimized using the F1-score calculated from both the inliers and validation outliers' data. RESULTS 308 pelvis and 200 thorax fields were used in this study. The tolerance (action) limits for 2%/2 mm, 2%/1 mm, and 1%/1 mm gamma criteria in the pelvis site are 99.1% (98.1%), 95.8% (91.1%), and 91.7% (86.1%), respectively. The tolerance (action) limits in the thorax site are 99.0% (98.7%), 97.0% (96.2%), and 91.5% (87.2%). One class support vector machine performs the best among all the algorithms. The best performing model in the thorax (pelvis) site achieves a precision of 0.56 (0.54), recall of 1.0 (1.0), and F1-score of 0.72 (0.70) when using the 2%/2 mm (2%/1 mm) criterion. CONCLUSION The model will help the planner to identify an out-of-tolerance plan early so that they can refine the plan further during the planning stage without risking late discovery during measurement.
Collapse
Affiliation(s)
- Hong Qi Tan
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
- Oncology Academic Clinical ProgrammeDuke‐NUS Medical SchoolSingaporeSingapore
| | - Kah Seng Lew
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
- Division of Physics and Applied PhysicsNanyang Technological UniversitySingaporeSingapore
| | - Yun Ming Wong
- Division of Physics and Applied PhysicsNanyang Technological UniversitySingaporeSingapore
| | - Wen Chuan Chong
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
| | - Calvin Wei Yang Koh
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
| | | | - Ping Lin Yeap
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
| | - Khong Wei Ang
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
| | - James Cheow Lei Lee
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
- Division of Physics and Applied PhysicsNanyang Technological UniversitySingaporeSingapore
| | - Sung Yong Park
- Division of Radiation OncologyNational Cancer Centre SingaporeSingaporeSingapore
- Oncology Academic Clinical ProgrammeDuke‐NUS Medical SchoolSingaporeSingapore
| |
Collapse
|
5
|
Udee N, Commukchik S, Khamfongkhruea C, Kaewlek T, Chusin T, Yabsantia S. Delta 4-based Dosimetric Error Detection in Volumetric-modulated Arc Therapy: Clinical Significance and Implications. J Med Phys 2024; 49:56-63. [PMID: 38828070 PMCID: PMC11141741 DOI: 10.4103/jmp.jmp_140_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 12/01/2023] [Accepted: 12/01/2023] [Indexed: 06/05/2024] Open
Abstract
Background Volumetric-modulated arc therapy (VMAT) is an efficient method of administering intensity-modulated radiotherapy beams. The Delta4 device was employed to examine patient data. Aims and Objectives The utility of the Delta4 device in identifying errors for patient-specific quality assurance of VMAT plans was studied in this research. Materials and Methods Intentional errors were purposely created in the collimator rotation, gantry rotation, multileaf collimator (MLC) position displacement, and increase in the number of monitor units (MU). Results The results show that when the characteristics of the treatment plans were changed, the gamma passing rate (GPR) decreased. The largest percentage of erroneous detection was seen in the increasing number of MU, with a GPR ranging from 41 to 92. Gamma analysis was used to compare the dose distributions of the original and intentional error designs using the 2%/2 mm criteria. The percentage of dose errors (DEs) in the dose-volume histogram (DVH) was also analyzed, and the statistical association was assessed using logistic regression. A modest association (Pearson's R-values: 0.12-0.67) was seen between the DE and GPR in all intentional plans. The findings indicated a moderate association between DVH and GPR. The data reveal that Delta4 is effective in detecting mistakes in treatment regimens for head-and-neck cancer as well as lung cancer. Conclusion The study results also imply that Delta4 can detect errors in VMAT plans, depending on the details of the defects and the treatment plans employed.
Collapse
Affiliation(s)
- Nuntawat Udee
- Department of Radiological Technology, Faculty of Allied Health Sciences, Naresuan University, Phitsanulok, Thailand
| | - Supada Commukchik
- Department of Radiation Therapy, Udon Thani Cancer Hospital, Udon Thani, Thailand
| | - Chirasak Khamfongkhruea
- Department of Radiation Therapy, Radiation Oncology Unit, Chulabhorn Hospital, Bangkok, Thailand
| | - Titipong Kaewlek
- Department of Radiological Technology, Faculty of Allied Health Sciences, Naresuan University, Phitsanulok, Thailand
| | - Thunyarat Chusin
- Department of Radiological Technology, Faculty of Allied Health Sciences, Naresuan University, Phitsanulok, Thailand
| | - Sumalee Yabsantia
- Department of Radiological Technology, Faculty of Allied Health Sciences, Naresuan University, Phitsanulok, Thailand
| |
Collapse
|
6
|
Sağlam Y. A novel weight optimized dynamic conformal arcs with TrueBeam™ Linac for very small tumors (≤1 cc) with single isocenter of multiple brain metastases (2≤, ≥4) in stereotactic radiosurgery: A comparison with volumetric modulated arc therapy. J Cancer Res Ther 2023; 19:1297-1304. [PMID: 37787298 DOI: 10.4103/jcrt.jcrt_1829_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
Introduction We evaluated whether improved increase delivery efficiency of weight optimized dynamic conformal arc (WO-DCA) therapy in comparison to volumetric modulated arc therapy (VMAT) with single isocenter for SRS treatment of very small volume and multiple brain metastases (BMs). Materials and Methods 20 patients having a less than 1 cc volume and 2≤, ≥4 of multiple BMs, redesigned for 20 Gy in 1 fraction using WO-DCA and VMAT techniques with double full coplanar and three partial noncoplanar arcs. Plan qualities were compared using tumor coverage, conformity index (CI), gradient index (GI), V4Gy, V10Gy, and V12Gy volumes of brain, monitor units (MUs), and percent of quality assurance pass rate (QA%). Results Both techniques satisfied clinical requirements in coverage and CI. VMAT had a significantly higher MU and mean GI than WO-DCA (for MUs; 2330 vs. 1991; P < 0.001, and for GI; 4.72 vs. 3.39; P < 0.001). WO-DCA was found significantly lower V4Gy (171.11 vs. 232.80 cm3, P < 0.001), V10Gy (25.82 vs. 29.71 cm3, P < 0.05), and V12Gy (14.35 vs. 17.28 cm3, P < 0.05) volumes than VMAT. WO-DCA was associated with markedly increase QA pass rates for all plans (97.65% vs. 92.64%, P < 0.001). Conclusions WO-DCA may be the first choice compared to the VMAT in reducing the dose in the brain and minimizing small-field dosimetric errors for very small SRS treatment of brain metastases in the range of ≤ 1 cc and 2≤, ≥4.
Collapse
Affiliation(s)
- Yücel Sağlam
- Department of Radiation Oncology, School of Medicine, Koc University, Topkapi, Istanbul, Turkey
| |
Collapse
|
7
|
Silvestri V, Raspanti D, Guerrisi MG, Falco MD. Clinical implementation of a log file-based machine and patient QA system for IMRT and VMAT treatment plans. Phys Med 2023; 108:102570. [PMID: 36989974 DOI: 10.1016/j.ejmp.2023.102570] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Revised: 03/04/2023] [Accepted: 03/18/2023] [Indexed: 03/29/2023] Open
Abstract
PURPOSE To determine the error detection sensitivity of a commercial log file-based system (LINACWatch®, LW) for integration into clinical routine and to compare it with a measurement device (OCTAVIUS 4D, Oct4D) for IMRT and VMAT delivery QA. MATERIALS AND METHODS 76 VMAT/IMRT plans (H&N, prostate, rectum and breast) preliminarily classified according to their Modulation Complexity Score (MCS) calculated by LW, were considered. Receiver Operating Characteristic (ROC) Curves were used to establish gamma criteria for LW. 12 plans (3 for each site) were intentionally modified in order to introduce delivery errors regarding MLC, jaws, collimator, gantry and MU (for a total set of 168 incorrect plans) and irradiated on Oct4D; the corresponding log files were analysed by LW. Each incorrect plan was compared to the error-free plan using γ-index analysis for MLC, jaws and MU errors investigation and Root-Mean-Square (RMS) values for gantry and collimator errors investigation. RESULTS MCS ranges values were: 0.10-0.20 for H&N, 0.21-0.40 for prostate and rectum, 0.41-1.00 for breast. From ROC curves, the Gamma Passing Rate (GPR) thresholds were: 87%, 92%, 99% for H&N, prostate and rectum, and breast, respectively. The 1.5%/1.5 mm/local criteria were adopted for the γ-analysis. LW sensitivity in detecting the introduced errors was higher when compared to Oct4D: 48.5% vs 30.4% respectively. CONCLUSIONS LW can be considered useful complement to phantom-based delivery QA of IMRT/VMAT plans. The MCS tool is effective in detecting over or under modulated plans prior to pre-treatment QA. However, rigorous and routinely machine QCs are recommended.
Collapse
|
8
|
Huang J, Hu J, Lu H, Liu S, Gong F, Wu X, Liu Y, Shi J. Error detection using EPID-based 3D in vivo dose verification for lung stereotactic body radiotherapy. Appl Radiat Isot 2023; 192:110567. [PMID: 36459899 DOI: 10.1016/j.apradiso.2022.110567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 10/21/2022] [Accepted: 11/15/2022] [Indexed: 11/26/2022]
Abstract
PURPOSE To investigate the error detectability limitations of an EPID-based 3D in vivo dosimetry verification system for lung stereotactic body radiation therapy (SBRT). METHODS Thirty errors were intentionally introduced, consisting of dynamic and constant machine errors, to simulate the possible errors that may occur during delivery. The dynamic errors included errors in the output, gantry angle and MLC positions related to gantry inertial and gravitational effects, while the constant errors included errors in the collimator angle, jaw positions, central leaf positions, setup shift and thickness to simulate patient weight loss. These error plans were delivered to a CIRS phantom using the SBRT technique for lung cancer. Following irradiation of these error plans, the dose distribution was reconstructed using iViewDose™ and compared with the no error plan. RESULTS All errors caused by the central leaf positions, dynamic MLC errors, Jaw inwards movements, setup shifts and patient anatomical changes were successfully detected. However, dynamic gantry angle and collimator angle errors were not detected in the lung case due to the rotation-symmetric target shape. The results showed that the γmean and γpassrate indicators can detect 13 (81.3%) and 14 (87.5%) of the 16 errors respectively without including the gantry angle error, collimator angle error and output error. CONCLUSIONS In summary, iViewDose™ is an appropriate approach for detecting most types of clinical errors for lung SBRT. However, the phantom results also showed some detectability limitations of the system in terms of dynamic gantry angle and constant collimator angle errors.
Collapse
Affiliation(s)
- Jianghua Huang
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, 510120, China; Department of Radiation Oncology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, 510120, China
| | - Jinyan Hu
- Department of Oncology, Longhua District People's Hospital, Shenzhen, Guangdong Province, 518109, China
| | - Huanping Lu
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, 510120, China; Department of Radiation Oncology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, 510120, China
| | - Shijie Liu
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, 510120, China; Department of Radiation Oncology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, 510120, China
| | - Fengying Gong
- Department of Traditonal Chinese Medicine, Nanfang Hospital of Southern Medical University, Guangzhou, 510515, China
| | - Xiuxiu Wu
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, 510120, China; Department of Radiation Oncology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, 510120, China
| | - Yimin Liu
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, 510120, China; Department of Radiation Oncology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, 510120, China.
| | - Juntian Shi
- Guangdong Provincial Key Laboratory of Malignant Tumor Epigenetics and Gene Regulation, Medical Research Center, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, 510120, China; Department of Radiation Oncology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, 510120, China.
| |
Collapse
|
9
|
Electronic Portal Imaging Device in Pre-Treatment Patient-Specific Quality Assurance of volumetric-modulated arc therapy delivery. JOURNAL OF RADIOTHERAPY IN PRACTICE 2023. [DOI: 10.1017/s1460396922000334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022]
Abstract
Abstract
Background:
Radiotherapy treatment delivery is evaluated by a pre-treatment patient-specific quality assurance (PSQA) procedure to ensure the patient receives an accurate radiation dose. The current PSQA practice by using conventional phantoms requires more set-up time and cost of purchasing the tools. Therefore, this study aimed to investigate the efficiency of an electronic portal imaging device (EPID) of linear accelerator (LINAC) as a PSQA tool for volumetric-modulated arc therapy (VMAT) planning technique for nasopharyngeal carcinoma (NPC) treatment delivery.
Methods:
A NPC VMAT plan on a Rando phantom was performed by following the Radiation Therapy Oncology Group (RTOG) 0615 protocol. The gamma passing rate of the EPID and PSQA phantom (ArcCHECK) were compared among the gamma criteria of 3%/3 mm, 2%/2 mm and 1%/1 mm, respectively.
Results:
Both EPID and ArcCHECK phantom had distinguishable gamma passing rates in 3%/3 mm and 2%/2 mm with a difference of 0·87% and 0·30%, respectively. Meanwhile, the EPID system had a lower gamma passing rate than the ArcCHECK phantom in 1%/1 mm (21·23% difference). Furthermore, the sensitivity of the EPID system was evaluated and had the largest deviation in gamma passing rate from the reference position in gamma criteria of 2%/2 mm (41·14%) compared to the 3%/3 mm (25·45%) and 1%/1 mm (31·78%), discretely. The best fit line of the linear regression model for EPID was steeper than the ArcCHECK phantom in 3%/3 mm and 2%/2 mm, and vice versa in gamma criteria of 1%/1 mm. This indicates that the EPID had a higher sensitivity than the ArcCHECK phantom in 3%/3 mm and 2%/2 mm but less sensitivity in 1%/1 mm.
Conclusions:
The EPID system was efficient in performing the PSQA test of VMAT treatment in HUSM with the gamma criteria of 3%/3 mm and 2%/2 mm.
Collapse
|
10
|
Pearson M, Butterworth V, Misson‐Yates S, Naeem M, Gonzalez Vaz R, Eaton D, Greener T. Application of failure mode and effects analysis to validate a novel hybrid Linac QC program that integrates automated and conventional QC testing. J Appl Clin Med Phys 2022; 23:e13798. [PMID: 36453139 PMCID: PMC9797170 DOI: 10.1002/acm2.13798] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2022] [Revised: 09/01/2022] [Accepted: 09/09/2022] [Indexed: 12/05/2022] Open
Abstract
A hybrid quality control (QC) program was developed that integrates automated and conventional Linac QC, realizing the benefits of both automated and conventional QC, increasing efficiency and maintaining independent measurement methods. Failure mode and effects analysis (FMEA) was then applied in order to validate the program prior to clinical implementation. The hybrid QC program consists of automated QC with machine performance check and DailyQA3 array on the TrueBeam Linac, and Delta4 volumetric modulated arc therapy (VMAT) standard plan measurements, alongside conventional monthly QC at a reduced frequency. The FMEA followed the method outlined in TG-100. Process maps were created for each treatment type at our center: VMAT, stereotactic body radiotherapy (SBRT), conformal, and palliative. Possible failure modes were established by evaluating each stage in the process map. The FMEA followed semiquantitative methods, using data from our QC records from eight Linacs over 3 years for the occurrence estimates, and simulation of failure modes in the treatment planning system, with scoring surveys for severity and detectability. The risk priority number (RPN) was calculated from the product of the occurrence, severity, and detectability scores and then normalized to the maximum and ranked to determine the most critical failure modes. The highest normalized RPN values (100, 90) were found to be for MLC position dynamic for both VMAT and SBRT treatments. The next highest score was 35 for beam position for SBRT, and the majority of scores were less than 20. Overall, these RPN scores for the hybrid Linac QC program indicated that it would be acceptable, but the high RPN score associated with the dynamic MLC failure mode indicates that it would be valuable to perform more rigorous testing of the MLC. The FMEA proved to be a useful tool in validating hybrid QC.
Collapse
Affiliation(s)
- Michael Pearson
- Medical Physics DepartmentGuy's and St Thomas' HospitalLondonUK
| | | | - Sarah Misson‐Yates
- Medical Physics DepartmentGuy's and St Thomas' HospitalLondonUK,School of Biomedical Engineering & Imaging SciencesKing's College LondonLondonUK
| | - Marium Naeem
- Medical Physics DepartmentGuy's and St Thomas' HospitalLondonUK
| | | | - David Eaton
- Medical Physics DepartmentGuy's and St Thomas' HospitalLondonUK,School of Biomedical Engineering & Imaging SciencesKing's College LondonLondonUK
| | - Tony Greener
- Medical Physics DepartmentGuy's and St Thomas' HospitalLondonUK
| |
Collapse
|
11
|
Deng J, Huang Y, Wu X, Hong Y, Zhao Y. Comparison of dosimetric effects of MLC positional errors on VMAT and IMRT plans for SBRT radiotherapy in non-small cell lung cancer. PLoS One 2022; 17:e0278422. [PMID: 36454884 PMCID: PMC9714892 DOI: 10.1371/journal.pone.0278422] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Accepted: 11/15/2022] [Indexed: 12/02/2022] Open
Abstract
The positional accuracy of multi-leaf collimators (MLC) is important in stereotactic body radiotherapy (SBRT). The aim of this study was to investigate the impact between MLC positional error and dosimetry of volume intensity modulated (VMAT) and general intensity modulated (IMRT) plans for non-small cell lung cancer (NSCLC). Fifteen patients with NSCLC were selected to design the 360 SBRT-VMAT plans and the 360 SBRT-IMRT error plans. The DICOM files for these treatment plans were imported into a proprietary computer program that introduced delivery errors. Random and systematic MLC position (0.1, 0.2, 0.5, 1.0, 1.5, and 2.0 mm) errors were introduced. The systematic errors were shift errors (caused by gravity), opening errors, and closing errors. The CI, GI, d2cm and generalized equivalent uniform dose (gEUD) were calculated for the original plan and all treatment plans, accounting for the errors. Dose sensitivity was calculated using linear regression for MLC position errors. The random MLC errors were relatively insignificant. MLC shift, opening, and closing errors had a significant effect on the dose distribution of the SBRT plan. VMAT was more significant than IMRT. To ensure that the gEUD variation of PTV is controlled within 2%, the shift error, opening error, and closing error of IMRT should be less than 2.4 mm, 1.15 mm, and 0.97 mm, respectively. For VMAT, the shift error, opening error, and closing error should be less than 0.95 mm, 0.32 mm, and 0.38 mm, respectively. The dose sensitivity results obtained in this study can be used as a guide for patient-based quality assurance efforts. The position error of the MLC system had a significant impact on the gEUD of the SBRT technology. The MLC systematic error has a greater dosimetric impact on the VMAT plan than on the IMRT plan for SBRT, which should be carefully monitored.
Collapse
Affiliation(s)
- Jia Deng
- Department of Radiation Oncology, Shaanxi Provincial Cancer Hospital, Xi’an, Shaanxi, People’s Republic of China
- School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an, Shaanxi, People’s Republic of China
- * E-mail:
| | - Yun Huang
- Department of Radiation Oncology, Xianyang Central Hospital, Xi’an, Shaanxi, People’s Republic of China
| | - Xiangyang Wu
- Department of Radiation Oncology, Shaanxi Provincial Cancer Hospital, Xi’an, Shaanxi, People’s Republic of China
| | - Ye Hong
- Center of Digestive Endoscopy, Shaanxi Provincial Cancer Hospital, Xi’an, Shaanxi, People’s Republic of China
| | - Yaolin Zhao
- School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an, Shaanxi, People’s Republic of China
| |
Collapse
|
12
|
Kim C, Han MC, Lee YK, Shin HB, Kim H, Kim JS. Comprehensive clinical evaluation of TomoEQA for patient-specific pre-treatment quality assurance in helical tomotherapy. Radiat Oncol 2022; 17:177. [DOI: 10.1186/s13014-022-02151-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Accepted: 10/24/2022] [Indexed: 11/09/2022] Open
Abstract
Abstract
Background
Based on a previous study on the feasibility of TomoEQA, an exit detector-based patient-specific pre-treatment quality assurance (QA) method for helical tomotherapy, an in-depth clinical evaluation was conducted.
Methods
Data of one hundred patients were analyzed to evaluate the clinical usefulness of TomoEQA for patient-specific pre-treatment QA in comparison with the conventional phantom-based method. Additional investigations were also performed under unusual measurement conditions to validate the off-axis region. In addition to the clinical evaluation of TomoEQA, a statistical analysis was conducted to determine the plan parameters that affect the pass/failure results of pre-treatment QA.
Results
The average and standard deviations of the gamma passing rate and point dose error for TomoEQA were comparable to those of the conventional QA method. For TomoEQA, the average values of the gamma passing rate and point dose error were 96.32% (standard deviation (1 sigma) = 3.94; 95% confidence interval (CI), 95.55 to 97.09) and − 1.12% (standard deviation (1 sigma) = 1.04; CI, − 1.32 to − 0.92), respectively. For the conventional QA method, the average values of the gamma passing rate and point dose error were 95.95% (standard deviation (1 sigma) = 4.35; 95% confidence interval (CI), 95.10 to 96.80) and − 1.20% (standard deviation (1 sigma) = 1.61; CI, − 1.52 to − 0.88), respectively. Further experiments on the off-axis region demonstrated that TomoEQA can provide accurate results for 3D dose analysis, which is inherently difficult in the conventional QA method. Through a statistical analysis based on the results of TomoEQA, it was validated that the total fraction (Total Fx), monitor units, beam-on-time, leaf-of-time below 100 ms, and planning target volume diameter were statistically significant for the pass/failure of the pre-treatment QA results.
Conclusions
TomoEQA is a clinically beneficial alternative to the conventional phantom-based QA method.
Collapse
|
13
|
Zhang H, Lu W, Cui H, Li Y, Yi X. Assessment of Statistical Process Control Based DVH Action Levels for Systematic Multi-Leaf Collimator Errors in Cervical Cancer RapidArc Plans. Front Oncol 2022; 12:862635. [PMID: 35664736 PMCID: PMC9157499 DOI: 10.3389/fonc.2022.862635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Accepted: 04/19/2022] [Indexed: 11/18/2022] Open
Abstract
Background In the patient-specific quality assurance (QA), DVH is a critical clinically relevant parameter that is finally used to determine the safety and effectiveness of radiotherapy. However, a consensus on DVH-based action levels has not been reached yet. The aim of this study is to explore reasonable DVH-based action levels and optimal DVH metrics in detecting systematic MLC errors for cervical cancer RapidArc plans. Methods In this study, a total of 148 cervical cancer RapidArc plans were selected and measured with COMPASS 3D dosimetry system. Firstly, the patient-specific QA results of 110 RapidArc plans were retrospectively reviewed. Then, DVH-based action limits (AL) and tolerance limits (TL) were obtained by statistical process control. Secondly, systematic MLC errors were introduced in 20 RapidArc plans, generating 380 modified plans. Then, the dose difference (%DE) in DVH metrics between modified plans and original plans was extracted from measurement results. After that, the linear regression model was used to investigate the detection limits of DVH-based action levels between %DE and systematic MLC errors. Finally, a total of 180 test plans (including 162 error-introduced plans and 18 original plans) were prepared for validation. The error detection rate of DVH-based action levels was compared in different DVH metrics of 180 test plans. Results A linear correlation was found between systematic MLC errors and %DE in all DVH metrics. Based on linear regression model, the systematic MLC errors between -0.94 mm and 0.88 mm could be caught by the TL of PTV95 ([-1.54%, 1.51%]), and the systematic MLC errors between -1.00 mm and 0.80 mm could also be caught by the TL of PTVmean ([-2.06%, 0.38%]). In the validation, for original plans, PTV95 showed the minimum error detection rate of 5.56%. For error-introduced plans with systematic MLC errors more than 1mm, PTVmean showed the maximum error detection rate of 88.89%, and then was followed by PTV95 (86.67%). All the TL of DVH metrics showed a poor error detection rate in identifying error-induced plans with systematic MLC errors less than 1mm. Conclusion In 3D quality assurance of cervical cancer RapidArc plans, process-based tolerance limits showed greater advantages in distinguishing plans introduced with systematic MLC errors more than 1mm, and reasonable DVH-based action levels can be acquired through statistical process control. During DVH-based verification, main focus should be on the DVH metrics of target volume. OARs in low-dose regions were found to have a relatively higher dose sensitivity to smaller systematic MLC errors, but may be accompanied with higher false error detection rate.
Collapse
Affiliation(s)
- Hanyin Zhang
- Department of Oncology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Wenli Lu
- Department of Oncology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Haixia Cui
- Department of Oncology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Ying Li
- Department of Oncology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Xin Yi
- Department of Oncology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| |
Collapse
|
14
|
Gray A, Bawazeer O, Arumugam S, Vial P, Descallar J, Thwaites D, Holloway L. Evaluation of the ability of three commercially available dosimeters to detect systematic delivery errors in step-and-shoot IMRT plans. Rep Pract Oncol Radiother 2021; 26:793-803. [PMID: 34760314 DOI: 10.5603/rpor.a2021.0093] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2021] [Accepted: 07/03/2021] [Indexed: 11/25/2022] Open
Abstract
Background There is limited data on error detectability for step-and-shoot intensity modulated radiotherapy (sIMRT) plans, despite significant work on dynamic methods. However, sIMRT treatments have an ongoing role in clinical practice. This study aimed to evaluate variations in the sensitivity of three patient-specific quality assurance (QA) devices to systematic delivery errors in sIMRT plans. Materials and methods Four clinical sIMRT plans (prostate and head and neck) were edited to introduce errors in: Multi-Leaf Collimator (MLC) position (increasing field size, leaf pairs offset (1-3 mm) in opposite directions; and field shift, all leaves offset (1-3 mm) in one direction); collimator rotation (1-3 degrees) and gantry rotation (0.5-2 degrees). The total dose for each plan was measured using an ArcCHECK diode array. Each field, excluding those with gantry offsets, was also measured using an Electronic Portal Imager and a MatriXX Evolution 2D ionisation chamber array. 132 plans (858 fields) were delivered, producing 572 measured dose distributions. Measured doses were compared to calculated doses for the no-error plan using Gamma analysis with 3%/3 mm, 3%/2 mm, and 2%/2 mm criteria (1716 analyses). Results Generally, pass rates decreased with increasing errors and/or stricter gamma criteria. Pass rate variations with detector and plan type were also observed. For a 3%/3 mm gamma criteria, none of the devices could reliably detect 1 mm MLC position errors or 1 degree collimator rotation errors. Conclusions This work has highlighted the need to adapt QA based on treatment plan type and the need for detector specific assessment criteria to detect clinically significant errors.
Collapse
Affiliation(s)
- Alison Gray
- Liverpool and Macarthur Cancer Therapy Centres, South Western Sydney Local Health District, Sydney, NSW, Australia.,Ingham Institute for Applied Medical Research, Sydney, NSW, Australia.,South Western Sydney Clinical School, School of Medicine, University of New South Wales, Sydney, NSW, Australia
| | - Omemh Bawazeer
- Physics Department, Umm Al-Qura University, Mecca, Saudi Arabia
| | - Sankar Arumugam
- Liverpool and Macarthur Cancer Therapy Centres, South Western Sydney Local Health District, Sydney, NSW, Australia.,Ingham Institute for Applied Medical Research, Sydney, NSW, Australia.,South Western Sydney Clinical School, School of Medicine, University of New South Wales, Sydney, NSW, Australia
| | - Philip Vial
- Liverpool and Macarthur Cancer Therapy Centres, South Western Sydney Local Health District, Sydney, NSW, Australia.,Ingham Institute for Applied Medical Research, Sydney, NSW, Australia.,South Western Sydney Clinical School, School of Medicine, University of New South Wales, Sydney, NSW, Australia.,Institute of Medical Physics, School of Physics, University of Sydney, Sydney, NSW, Australia
| | - Joseph Descallar
- Ingham Institute for Applied Medical Research, Sydney, NSW, Australia.,South Western Sydney Clinical School, School of Medicine, University of New South Wales, Sydney, NSW, Australia
| | - David Thwaites
- Institute of Medical Physics, School of Physics, University of Sydney, Sydney, NSW, Australia
| | - Lois Holloway
- Liverpool and Macarthur Cancer Therapy Centres, South Western Sydney Local Health District, Sydney, NSW, Australia.,Ingham Institute for Applied Medical Research, Sydney, NSW, Australia.,South Western Sydney Clinical School, School of Medicine, University of New South Wales, Sydney, NSW, Australia.,Institute of Medical Physics, School of Physics, University of Sydney, Sydney, NSW, Australia.,Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia
| |
Collapse
|
15
|
Saglam Y, Bolukbasi Y, Atasoy AI, Karakose F, Budak M, Alpan V, Topkan E, Selek U. Novel Clinically Weight-Optimized Dynamic Conformal Arcs (WO-DCA) for Liver SBRT: A Comparison with Volumetric Modulated Arc Therapy (VMAT). Ther Clin Risk Manag 2021; 17:1053-1064. [PMID: 34611405 PMCID: PMC8487279 DOI: 10.2147/tcrm.s328375] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2021] [Accepted: 09/11/2021] [Indexed: 12/28/2022] Open
Abstract
PURPOSE To evaluate the feasibility of shortening the duration of liver stereotactic radiotherapy (SBRT) without jeopardizing dosimetry or conformity by utilizing weight-optimized dynamic conformal arcs (WO-DCA) as opposed to volumetric modulated arc therapy (VMAT) for tumors away from critical structures. METHODS Nineteen patients with liver metastasis were included, previously treated with 50 Gy in 4 fractions with VMAT technique using two partial coplanar arcs of 6 MV beams delivered in high-definition multi-leaf collimator (HD-MLC). Two coplanar partial WO-DCA were generated on Pinnacle treatment planning system (TPS) for each patient; and MLC aperture around the planning target volume (PTV) was automatically generated at different margins for both arcs and maintained dynamically around the target during arc rotation. Weight of the two arcs using optimization method was adjusted between the arcs to maximize tumor coverage and protect organs at risk (OAR) based on the RTOG-0438 protocol. RESULTS The WO-DCA plans successfully "agreed" with the standard VMAT for OAR (liver, spinal cord, stomach, duodenum, small bowel, and heart) and PTV (Dmean, D98%, D2%, CI, and GI), with superior mean quality assurance (QA) pass rate (97.06 vs 93.00 for VMAT; P < 0.001 and t = 8.87). Similarly, the WO-DCA technique additionally reduced the beam-on time (3.26 vs 4.43; P < 0.001) and monitor unit (1860 vs 2705 for VMAT; P < 0.001) values significantly. CONCLUSION The WO-DCA plans might minimize small-field dosimetry errors and defeat patient-specific VMAT QA requirements due to the omission of MLC beam modulation through the target volume. The WO-DCA plans may additionally enable faster treatment delivery times and lower OAR without sacrificing target doses in SBRT of liver tumors away from critical structures.
Collapse
Affiliation(s)
- Yucel Saglam
- Koc University, School of Medicine, Department of Radiation Oncology, Istanbul, Turkey
- UT MD Anderson Radiation Oncology Outreach Center at American Hospital, Istanbul, Turkey
| | - Yasemin Bolukbasi
- Koc University, School of Medicine, Department of Radiation Oncology, Istanbul, Turkey
- UT MD Anderson Radiation Oncology Outreach Center at American Hospital, Istanbul, Turkey
- University of Texas, MD Anderson Cancer Center, Department of Radiation Oncology, Houston, TX, USA
| | - Ali Ihsan Atasoy
- Koc University, School of Medicine, Department of Radiation Oncology, Istanbul, Turkey
| | - Fatih Karakose
- Koc University, School of Medicine, Department of Radiation Oncology, Istanbul, Turkey
| | - Mustafa Budak
- Koc University, School of Medicine, Department of Radiation Oncology, Istanbul, Turkey
| | - Vildan Alpan
- Koc University, School of Medicine, Department of Radiation Oncology, Istanbul, Turkey
- UT MD Anderson Radiation Oncology Outreach Center at American Hospital, Istanbul, Turkey
| | - Erkan Topkan
- Baskent University Medical Faculty, Department of Radiation Oncology, Adana, Turkey
| | - Ugur Selek
- Koc University, School of Medicine, Department of Radiation Oncology, Istanbul, Turkey
- UT MD Anderson Radiation Oncology Outreach Center at American Hospital, Istanbul, Turkey
- University of Texas, MD Anderson Cancer Center, Department of Radiation Oncology, Houston, TX, USA
| |
Collapse
|
16
|
Retrospective analysis of portal dosimetry pre-treatment quality assurance of intracranial SRS/SRT VMAT treatment plans. JOURNAL OF RADIOTHERAPY IN PRACTICE 2021. [DOI: 10.1017/s146039692100042x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Abstract
Background:
The complexity associated with the treatment planning and delivery of stereotactic radiosurgery (SRS) or stereotactic radiotherapy (SRT) volumetric modulated arc therapy (VMAT) plans which employs continuous dynamic modulation of dose rate, field aperture and gantry speed necessitates diligent pre-treatment patient-specific quality assurance (QA). Numerous techniques for pre-treatment VMAT treatment plans QA are currently available with the aid of several different devices including the electronic portal imager (EPID). Although several studies have provided recommendations for gamma criteria for VMAT pre-treatment QA, there are no specifics for SRS/SRT VMAT QA. Thus, we conducted a study to evaluate intracranial SRS/SRT VMAT QA to determine clinical action levels for gamma criteria based on the institutional estimated means and standard deviations.
Materials and methods:
We conducted a retrospective analysis of 118 EPID patient-specific pre-treatment QA dosimetric measurements of 47 brain SRS/SRT VMAT treatment plans using the integrated Varian solution (RapidArcTM planning, EPID and Portal dosimetry system) for planning, delivery and EPID QA analysis. We evaluated the maximum gamma (γmax), average gamma (γave) and percentage gamma passing rate (%GP) for different distance-to-agreement/dose difference (DTA/DD) criteria and low-dose thresholds.
Results:
The gamma index analysis shows that for patient-specific SRS/SRT VMAT QA with the portal dosimetry, the mean %GP is ≥98% for 2–3 mm/1–3% and Field+0%, +5% and +10% low-dose thresholds. When applying stricter spatial criteria of 1 mm, the mean %GP is >90% for DD of 2–3% and ≥88% for DD of 1%. The mean γmax ranges: 1·32 ± 1·33–2·63 ± 2·35 for 3 mm/1–3%, 1·57 ± 1·36–2·87 ± 2·29 for 2 mm/1–3% and 2·36 ± 1·83–3·58 ± 2·23 for 1 mm/1–3%. Similarly the mean γave ranges: 0·16 ± 0·06–0·19 ± 0·07 for 3 mm/1–3%, 0·21 ± 0·08–0·27 ± 0·10 for 2 mm/1–3% and 0·34 ± 0·14–0·49 ± 0·17 for 1 mm/1–3%. The mean γmax and mean γave increase with increased DTA and increased DD for all low-dose thresholds.
Conclusions:
The establishment of gamma criteria local action levels for SRS/SRT VMAT pre-treatment QA based on institutional resources is imperative as a useful tool for standardising the evaluation of EPID-based patient-specific SRS/SRT VMAT QA. Our data suggest that for intracranial SRS/SRT VMAT QA measured with the EPID, a stricter gamma criterion of 1 mm/2% or 1 mm/3% with ≥90% %GP could be used while still maintaining an in-control QA process with no extra burden on resources and time constraints.
Collapse
|
17
|
Tattenberg S, Hyde D, Milette MP, Parodi K, Araujo C, Carlone M. Assessment of the Sun Nuclear ArcCHECK to detect errors in 6MV FFF VMAT delivery of brain SABR using ROC analysis. J Appl Clin Med Phys 2021; 22:35-44. [PMID: 34021691 PMCID: PMC8200516 DOI: 10.1002/acm2.13276] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2020] [Revised: 03/24/2021] [Accepted: 04/19/2021] [Indexed: 11/11/2022] Open
Abstract
Institutions use a range of different detector systems for patient-specific quality assurance (QA) measurements conducted to assure that the dose delivered by a patient's radiotherapy treatment plan matches the calculated dose distribution. However, the ability of different detectors to detect errors from different sources is often unreported. This study contains a systematic evaluation of Sun Nuclear's ArcCHECK in terms of the detectability of potential machine-related treatment errors. The five investigated sources of error were multileaf collimator (MLC) leaf positions, gantry angle, collimator angle, jaw positions, and dose output. The study encompassed the clinical treatment plans of 29 brain cancer patients who received stereotactic ablative radiotherapy (SABR). Six error magnitudes were investigated per source of error. In addition, the Eclipse AAA beam model dosimetric leaf gap (DLG) parameter was varied with four error magnitudes. Error detectability was determined based on the area under the receiver operating characteristic (ROC) curve (AUC). Detectability of DLG errors was good or excellent (AUC >0.8) at an error magnitude of at least ±0.4 mm, while MLC leaf position and gantry angle errors reached good or excellent detectability at error magnitudes of at least 1.0 mm and 0.6°, respectively. Ideal thresholds, that is, gamma passing rates, to maximize sensitivity and specificity ranged from 79.1% to 98.7%. The detectability of collimator angle, jaw position, and dose output errors was poor for all investigated error magnitudes, with an AUC between 0.5 and 0.6. The ArcCHECK device's ability to detect errors from treatment machine-related sources was evaluated, and ideal gamma passing rate thresholds were determined for each source of error. The ArcCHECK was able to detect errors in DLG value, MLC leaf positions, and gantry angle. The ArcCHECK was unable to detect the studied errors in collimator angle, jaw positions, and dose output.
Collapse
Affiliation(s)
- Sebastian Tattenberg
- Department of Medical Physics, Ludwig Maximilian University of Munich, Garching, Germany.,Irving K. Barber Faculty of Science, University of British Columbia, Okanagan Campus, Kelowna, BC, Canada
| | - Derek Hyde
- Irving K. Barber Faculty of Science, University of British Columbia, Okanagan Campus, Kelowna, BC, Canada.,Centre for the Southern Interior, Department of Medical Physics, BC Cancer Agency, Kelowna, BC, Canada
| | - Marie-Pierre Milette
- Irving K. Barber Faculty of Science, University of British Columbia, Okanagan Campus, Kelowna, BC, Canada.,Centre for the Southern Interior, Department of Medical Physics, BC Cancer Agency, Kelowna, BC, Canada
| | - Katia Parodi
- Department of Medical Physics, Ludwig Maximilian University of Munich, Garching, Germany
| | - Cynthia Araujo
- Irving K. Barber Faculty of Science, University of British Columbia, Okanagan Campus, Kelowna, BC, Canada.,Centre for the Southern Interior, Department of Medical Physics, BC Cancer Agency, Kelowna, BC, Canada
| | - Marco Carlone
- Irving K. Barber Faculty of Science, University of British Columbia, Okanagan Campus, Kelowna, BC, Canada.,Centre for the Southern Interior, Department of Medical Physics, BC Cancer Agency, Kelowna, BC, Canada
| |
Collapse
|
18
|
Honda H, Tominaga M, Sasaki M, Oita M, Kanzaki H, Hamamoto Y, Ishii Y, Yamamoto R, Mochizuki T, Kido T, Uto Y. Usability of detecting delivery errors during treatment of prostate VMAT with a gantry-mounted transmission detector. J Appl Clin Med Phys 2021; 22:66-76. [PMID: 33955161 PMCID: PMC8292707 DOI: 10.1002/acm2.13260] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Revised: 03/09/2021] [Accepted: 03/30/2021] [Indexed: 11/14/2022] Open
Abstract
Volumetric‐modulated arc therapy (VMAT) requires highly accurate control of multileaf collimator (MLC) movement, rotation speed of linear accelerator gantry, and monitor units during irradiation. Pretreatment validation and monitoring of these factors during irradiation are necessary for appropriate VMAT treatment. Recently, a gantry mounted transmission detector “Delta4 Discover® (D4D)” was developed to detect errors in delivering doses and dose distribution immediately after treatment. In this study, the performance of D4D was evaluated. Simulation plans, in which the MLC position was displaced by 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 mm from the clinically used original plans, were created for ten patients who received VMAT treatment for prostate cancer. Dose deviation (DD), distance‐to‐agreement (DTA), and gamma index analysis (GA) for each plan were evaluated by D4D. These results were compared to the results (DD, DTA and GA) measured by Delta4 Phantom + (D4P). We compared the deviations between the planned and measured values of the MLC stop positions A‐side and B‐side in five clinical cases of prostate VMAT during treatment and measured the GA values. For D4D, when the acceptable errors for DD, DTA, and GA were determined to be ≤3%, ≤2 mm, and ≤3%/2 mm, respectively, the minimum detectable errors in the MLC position were 2.0, 1.5, and 1.5 mm based on DD, DTA, and GA respectively. The corresponding minimum detectable MLC position errors were 2.0, 1.0, and 1.5 mm, respectively, for D4P. The deviation between the planned and measured position of MLC stopping point of prostate VMAT during treatment was stable at an average of −0.09 ± 0.05 mm, and all GA values were above 99.86%. In terms of delivering doses and dose distribution of VMAT, error detectability of D4D was comparable to that of D4P. The transmission‐type detector “D4D” is thus suitable for detecting delivery errors during irradiation.
Collapse
Affiliation(s)
- Hirofumi Honda
- Department of Radiological Technology, Ehime University Hospital, Ehime, Japan.,Graduate School of Advanced Technology and Science, Tokushima University, Tokushima, Japan
| | - Masahide Tominaga
- Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima, Japan
| | - Motoharu Sasaki
- Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima, Japan
| | - Masataka Oita
- Okayama University Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama, Japan
| | - Hiromitsu Kanzaki
- Department of Radiation Therapy, National Hospital Organization Shikoku Cancer Center, Matsuyama, Japan
| | - Yasushi Hamamoto
- Department of Radiation Therapy, National Hospital Organization Shikoku Cancer Center, Matsuyama, Japan
| | - Yoshiaki Ishii
- Department of Radiological Technology, Ehime University Hospital, Ehime, Japan
| | - Ryuji Yamamoto
- Department of Radiological Technology, Ehime University Hospital, Ehime, Japan
| | - Teruhito Mochizuki
- Department of Radiology, Ehime University School of Medicine, Ehime, Japan
| | - Teruhito Kido
- Department of Radiology, Ehime University School of Medicine, Ehime, Japan
| | - Yoshihiro Uto
- Graduate School of Technology, Industrial and Social Science, Tokushima University, Tokushima, Japan
| |
Collapse
|
19
|
Alharthi T, Vial P, Holloway L, Thwaites D. Intrinsic detector sensitivity analysis as a tool to characterize ArcCHECK and EPID sensitivity to variations in delivery for lung SBRT VMAT plans. J Appl Clin Med Phys 2021; 22:229-240. [PMID: 33949087 PMCID: PMC8200424 DOI: 10.1002/acm2.13221] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2020] [Revised: 02/08/2021] [Accepted: 02/12/2021] [Indexed: 12/16/2022] Open
Abstract
PURPOSE To investigate intrinsic sensitivity of an electronic portal imaging device (EPID) and the ArcCHECK detector and to use this in assessing their performance in detecting delivery variations for lung SBRT VMAT. The effect of detector spatial resolution and dose matrix interpolation on the gamma pass rate was also considered. MATERIALS AND METHODS Fifteen patients' lung SBRT VMAT plans were used. Delivery variations (errors) were introduced by modifying collimator angles, multi-leaf collimator (MLC) field sizes and MLC field shifts by ±5, ±2, and ±1 degrees or mm (investigating 103 plans in total). EPID and ArcCHECK measured signals with introduced variations were compared to measured signals without variations (baseline), using OmniPro-I'mRT software and gamma criteria of 3%/3 mm, 2%/2 mm, 2%/1 mm, and 1%/1 mm, to test each system's basic performance. The measurement sampling resolution for each was also changed to 1 mm and results compared to those with the default detector system resolution. RESULTS Intrinsic detector sensitivity analysis, that is, comparing measurement to baseline measurement, rather than measurement to plan, demonstrated the intrinsic constraints of each detector and indicated the limiting performance that users might expect. Changes in the gamma pass rates for ArcCHECK, for a given introduced error, were affected only by dose difference (DD %) criteria. However, the EPID showed only slight changes when changing DD%, but greater effects when changing distance-to-agreement criteria. This is pertinent for lung SBRT where the minimum dose to the target will drop dramatically with geometric errors. Detector resolution and dose matrix interpolation have an impact on the gamma results for these SBRT plans and can lead to false positives or negatives in error detection if not understood. CONCLUSION The intrinsic sensitivity approach may help in the selection of more meaningful gamma criteria and the choice of optimal QA device for site-specific dose verification.
Collapse
Affiliation(s)
- Thahabah Alharthi
- Institute of Medical Physics, School of Physics, The University of Sydney, Sydney, NSW, Australia.,School of Medicine, Taif University, Taif, Saudi Arabia.,Liverpool and Macarthur Cancer Therapy Centers, Liverpool, NSW, Australia.,Ingham Institute for Applied Medical Research, Sydney, NSW, Australia
| | - Phil Vial
- Liverpool and Macarthur Cancer Therapy Centers, Liverpool, NSW, Australia.,Ingham Institute for Applied Medical Research, Sydney, NSW, Australia.,South Western Sydney Clinical School, University of New South Wales, Sydney, NSW, Australia
| | - Lois Holloway
- Institute of Medical Physics, School of Physics, The University of Sydney, Sydney, NSW, Australia.,Liverpool and Macarthur Cancer Therapy Centers, Liverpool, NSW, Australia.,Ingham Institute for Applied Medical Research, Sydney, NSW, Australia.,South Western Sydney Clinical School, University of New South Wales, Sydney, NSW, Australia.,Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia
| | - David Thwaites
- Institute of Medical Physics, School of Physics, The University of Sydney, Sydney, NSW, Australia
| |
Collapse
|
20
|
Lorenz FH, Paris MI. Identification of a potential source of error for 6FFF beams delivered on an Agility TM multileaf collimator. J Appl Clin Med Phys 2021; 22:92-98. [PMID: 33675145 PMCID: PMC8035561 DOI: 10.1002/acm2.13212] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Revised: 01/02/2021] [Accepted: 01/02/2021] [Indexed: 11/07/2022] Open
Abstract
Purpose The performance of the AgilityTM multileaf collimator was investigated with a focus on dynamic, small fields for flattening filter free (FFF) beams. Methods In this study we have developed a simple tool to test the robustness of the control mechanisms during dynamic beam delivery for Elekta’s VersaHD linear accelerator with Integrity 4.0.4 control software. We have programed the planning system to calculate dose for delivery of sweeping gaps. These sweeping gaps have a constant speed, constant size, and are delivered at a constant dose rate. Therefore they specifically identify delivery problems in dynamic mode. Results The Elekta AgilityTM control mechanism fails to maintain accurate delivery for small, dynamic sweeping gaps. For small gap sizes, the AgilityTM control mechanism delivers a field that is more than four times the size of the planned field width without generating an interlock. This has dosimetric implications: The discrepancy between calculated and measured doses increases with decreasing gap size and exceeds 10% and 60% at isocenter for a 3.5 mm and 1 mm gap size, respectively. Conclusion A deficiency of the AgilityTM control system was identified in this study. This deficiency is a potential source of error for volumetric modulated arc therapy fields and could therefore contribute to relatively high failure rates in quality assurance measurements, especially for FFF beams.
Collapse
Affiliation(s)
- Friedlieb H. Lorenz
- Department of Radiation OncologySouthern District Health BoardDunedinNew Zealand
| | - Matthew I. Paris
- Department of Radiation OncologySouthern District Health BoardDunedinNew Zealand
| |
Collapse
|
21
|
Sakai M, Nakano H, Kawahara D, Tanabe S, Takizawa T, Narita A, Yamada T, Sakai H, Ueda M, Sasamoto R, Kaidu M, Aoyama H, Ishikawa H, Utsunomiya S. Detecting MLC modeling errors using radiomics-based machine learning in patient-specific QA with an EPID for intensity-modulated radiation therapy. Med Phys 2021; 48:991-1002. [PMID: 33382467 DOI: 10.1002/mp.14699] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2020] [Revised: 11/27/2020] [Accepted: 12/18/2020] [Indexed: 11/06/2022] Open
Abstract
PURPOSE We sought to develop machine learning models to detect multileaf collimator (MLC) modeling errors with the use of radiomic features of fluence maps measured in patient-specific quality assurance (QA) for intensity-modulated radiation therapy (IMRT) with an electric portal imaging device (EPID). METHODS Fluence maps measured with EPID for 38 beams from 19 clinical IMRT plans were assessed. Plans with various degrees of error in MLC modeling parameters [i.e., MLC transmission factor (TF) and dosimetric leaf gap (DLG)] and plans with an MLC positional error for comparison were created. For a total of 152 error plans for each type of error, we calculated fluence difference maps for each beam by subtracting the calculated maps from the measured maps. A total of 837 radiomic features were extracted from each fluence difference map, and we determined the number of features used for the training dataset in the machine learning models by using random forest regression. Machine learning models using the five typical algorithms [decision tree, k-nearest neighbor (kNN), support vector machine (SVM), logistic regression, and random forest] for binary classification between the error-free plan and the plan with the corresponding error for each type of error were developed. We used part of the total dataset to perform fourfold cross-validation to tune the models, and we used the remaining test dataset to evaluate the performance of the developed models. A gamma analysis was also performed between the measured and calculated fluence maps with the criteria of 3%/2 and 2%/2 mm for all of the types of error. RESULTS The radiomic features and its optimal number were similar for the models for the TF and the DLG error detection, which was different from the MLC positional error. The highest sensitivity was obtained as 0.913 for the TF error with SVM and logistic regression, 0.978 for the DLG error with kNN and SVM, and 1.000 for the MLC positional error with kNN, SVM, and random forest. The highest specificity was obtained as 1.000 for the TF error with a decision tree, SVM, and logistic regression, 1.000 for the DLG error with a decision tree, logistic regression, and random forest, and 0.909 for the MLC positional error with a decision tree and logistic regression. The gamma analysis showed the poorest performance in which sensitivities were 0.737 for the TF error and the DLG error and 0.882 for the MLC positional error for 3%/2 mm. The addition of another type of error to fluence maps significantly reduced the sensitivity for the TF and the DLG error, whereas no effect was observed for the MLC positional error detection. CONCLUSIONS Compared to the conventional gamma analysis, the radiomics-based machine learning models showed higher sensitivity and specificity in detecting a single type of the MLC modeling error and the MLC positional error. Although the developed models need further improvement for detecting multiple types of error, radiomics-based IMRT QA was shown to be a promising approach for detecting the MLC modeling error.
Collapse
Affiliation(s)
- Madoka Sakai
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-754 Asahimachi-dori, Chuo-ku, Niigata, 951-8520, Japan
| | - Hisashi Nakano
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-754 Asahimachi-dori, Chuo-ku, Niigata, 951-8520, Japan
| | - Daisuke Kawahara
- Radiation Therapy Section, Department of Clinical Support, Hiroshima University Hospital, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
| | - Satoshi Tanabe
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-754 Asahimachi-dori, Chuo-ku, Niigata, 951-8520, Japan
| | - Takeshi Takizawa
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-754 Asahimachi-dori, Chuo-ku, Niigata, 951-8520, Japan.,Niigata Neurosurgical Hospital, 3057 Yamada, Nishi-ku, Niigata, 950-1101, Japan
| | - Akihiro Narita
- Department of Radiological Technology, Niigata University Graduate School of Health Sciences, 2-746 Asahimachi-dori, Chuo-ku, Niigata, 951-8518, Japan
| | - Takumi Yamada
- Section of Radiology, Department of Clinical Support, Niigata University Medical and Dental Hospital, 1-754 Asahimachi-dori, Chuo-ku, Niigata, 951-8520, Japan
| | - Hironori Sakai
- Section of Radiology, Department of Clinical Support, Niigata University Medical and Dental Hospital, 1-754 Asahimachi-dori, Chuo-ku, Niigata, 951-8520, Japan
| | - Masataka Ueda
- Department of Radiological Technology, Niigata University Graduate School of Health Sciences, 2-746 Asahimachi-dori, Chuo-ku, Niigata, 951-8518, Japan
| | - Ryuta Sasamoto
- Department of Radiological Technology, Niigata University Graduate School of Health Sciences, 2-746 Asahimachi-dori, Chuo-ku, Niigata, 951-8518, Japan
| | - Motoki Kaidu
- Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, 1-757 Asahimachi-dori, Chuo-ku, Niigata, 951-8510, Japan
| | - Hidefumi Aoyama
- Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, 1-757 Asahimachi-dori, Chuo-ku, Niigata, 951-8510, Japan.,Department of Radiation Oncology, Faculty of Medicine, Hokkaido University, N15 W7 Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Hiroyuki Ishikawa
- Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, 1-757 Asahimachi-dori, Chuo-ku, Niigata, 951-8510, Japan
| | - Satoru Utsunomiya
- Department of Radiological Technology, Niigata University Graduate School of Health Sciences, 2-746 Asahimachi-dori, Chuo-ku, Niigata, 951-8518, Japan
| |
Collapse
|
22
|
Lee YC, Kim Y. A patient-specific QA comparison between 2D and 3D diode arrays for single-lesion SRS and SBRT treatments. JOURNAL OF RADIOSURGERY AND SBRT 2021; 7:295-307. [PMID: 34631231 PMCID: PMC8492049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Accepted: 04/02/2021] [Indexed: 06/13/2023]
Abstract
The purpose of this study is to compare patient-specific quality assurance (PSQA) results between two dimensional (2D) diode (SRS MapCHECK®) and 3D diode (ArcCHECK®) arrays. Twenty-eight intracranial stereotactic radiosurgery (SRS) and 26 lung stereotactic body radiation therapy (SBRT) clinical plans with a single lesion were selected and categorized into 4 groups: 20 SRS dynamic conformal arc therapy (DCAT) plans (Group A), 8 SRS volumetric modulated arc therapy (VMAT) plans (Group B), 6 SBRT DCAT plans (Group C) and 20 SBRT VMAT plans (Group D). An individual field of each plan was delivered on SRS MapCHECK and ArcCHECK and QA analysis was performed using 4 gamma criteria of dose difference/distance-to-agreement of 3%/3 mm, 3%/2 mm, 2%/2 mm and 2%/1 mm. Statistical analysis was performed to compare PSQA results between the 2 QA devices. For all 4 groups and all 4 gamma criteria, average gamma passing rates were higher with SRS MapCHECK.
Collapse
Affiliation(s)
- Yongsook C Lee
- Department of Radiation Oncology, Miami Cancer Institute, Miami, FL 33176, USA
| | - Yongbok Kim
- Department of Radiation Oncology, Duke University, Durham, NC 27710, USA
| |
Collapse
|
23
|
Alves VGL, Ahmed M, Aliotta E, Choi W, Siebers JV. An error detection method for real-time EPID-based treatment delivery quality assurance. Med Phys 2020; 48:569-578. [PMID: 33314247 DOI: 10.1002/mp.14633] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2019] [Revised: 09/28/2020] [Accepted: 11/19/2020] [Indexed: 01/21/2023] Open
Abstract
PURPOSE To quantify the error detection power of a new treatment delivery error detection method. The method validates monitor unit (MU) resolved beam apertures using real-time EPID images. METHODS The on-board EPID imager was used to measure cine-EPID (~10 Hz) images for 27 beams from 15 VMAT/SBRT clinical treatment plans and five nonclinical plans. For each frame acquisition, planned apertures were interpolated from the treatment plan multileaf collimator (MLC) positions expected during the frame acquisition interval. Inaccurate deliveries were identified by monitoring in-aperture missed fluence and out-of-aperture excess fluence beyond a specified buffer. Delivery errors were simulated by perturbing the planned MLC positions before comparison with nonperturbed measured apertures. Systematic 1-5 mm MLC leaf shifts were used to train a logistic regression model to determine the error detection threshold. Model accuracy was monitored using tenfold cross-validation. The model's error detection ability was tested with other error modes: plan control point (CP) weight perturbations, collimator rotations, random MLC leaf position errors, EPID imager shift, and stuck MLC leaf. The error detection accuracy was evaluated using the Matthews correlation coefficient (MCC) and the false positive rate (FPR). Per-beam error thresholds of >1, >5, and >10% errant frames were tested to label per-beam errors. The model also was tested for its ability to distinguish five cases with highly similar plans and compared with gamma analysis. RESULTS Delivery errors were detected by monitoring intended per-frame images with a 2 mm MLC buffer. Frame-by-frame aperture errors were identified with an optimal threshold of 0.3% of the expected aperture area. The per-frame FPR was 0.02%. The MCC was 1.00 (perfect classification) for detection based on 1% of frames for random CP weight shift, 3 mm random MLC shifts, 90° and 180° collimator rotations, and an MLC leaf stuck after 10% of the beam delivery. The MCC for 2°, 4°, and 8° collimator rotation were 0.53, 0.76, and 0.96, respectively, for the 1% of beam delivery threshold. The 3 mm EPID shift had poor detection, with a minimum MCC of 0.14. The highly similar plans were reliably detected by the aperture check but were not detectable with gamma analysis. CONCLUSION The high error detection sensitivity and low FPR makes the aperture check error detection method well suited to pretreatment and during-treatment beam delivery quality assurance (QA). The aperture check detects subtle beam delivery errors, including those resulting from MLC leaf positioning deviations, CP MU shifts, and stuck MLC leaves. Furthermore, the method can distinguish between highly similar treatment plans. Since the aperture check method monitors for the aperture shapes over a given MU interval, it is also sensitive to errors in MU per CP, without requiring dosimetric calibration of the EPID. The aperture check is one part of a Swiss cheese error detection scheme, which provides redundant error testing of multiple error modes, including nonaperture related errors. The rapid error detection, at 1% of a beam's delivery, make the aperture check a potential candidate for QA of on-line adaptive radiotherapy, or other situations in which pretreatment delivery QA is impractical.
Collapse
Affiliation(s)
| | - Mahmoud Ahmed
- Department of Radiation Oncology, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Eric Aliotta
- Department of Radiation Oncology, University of Virginia Health System, Charlottesville, Virginia, USA
| | - Wookjin Choi
- Department of Radiation Oncology, University of Virginia Health System, Charlottesville, Virginia, USA
| | - Jeffrey Vincent Siebers
- Department of Radiation Oncology, University of Virginia Health System, Charlottesville, Virginia, USA
| |
Collapse
|
24
|
Zhao X, Zhang R. Feasibility of 3D tracking and adaptation of VMAT based on VMAT-CT. Radiother Oncol 2020; 149:18-24. [PMID: 32416375 DOI: 10.1016/j.radonc.2020.04.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2020] [Revised: 04/19/2020] [Accepted: 04/21/2020] [Indexed: 11/26/2022]
Abstract
BACKGROUND Local computed tomography (CT) reconstruction is achievable with portal images acquired during volumetric-modulated arc therapy (VMAT) delivery and was named as VMAT-CT. However, the application of VMAT-CT is limited because it has limited field of view and no density information. In addition, the new generation of multi-leaf collimator with faster speed and various collimator angles used in patients' plans could cause more artifacts in VMAT-CT. The goal of this study was to extend VMAT-CT concept, generate complete three-dimensional (3D) CT images, calculate new 3D dose, track and adapt VMAT plan based on updated images and dose. MATERIALS AND METHODS VMAT-CT and planning CT of phantoms were fused by rigid or deformable registration to create VMAT-CT+ images. Trackings based on planning CT, VMAT-CT+, and cone beam CT (CBCT) were compared. When prescription dose was not met for planning target volume (PTV), re-planning was demonstrated on an in-house deformable phantom. Possible uncertainties were also evaluated. RESULTS Tracking based on VMAT-CT+ was accurate and superior to those based on planning CT and CBCT since VMAT-CT+ can detect changes during treatment. PTV coverage in the deformable phantom decreased after deformations but went up and met the prescription goal after re-planning. The impact of uncertainties on dose was minimal. CONCLUSION 3D tracking and adaptation of VMAT based on VMAT-CT are feasible. Our study has the potential to increase the confidence of beam delivery, catch and remedy errors during VMAT.
Collapse
Affiliation(s)
- Xiaodong Zhao
- Department of Physics and Astronomy, Louisiana State University, Baton Rouge, USA
| | - Rui Zhang
- Department of Physics and Astronomy, Louisiana State University, Baton Rouge, USA; Department of Radiation Oncology, Mary Bird Perkins Cancer Center, Baton Rouge, USA.
| |
Collapse
|
25
|
Retrospective analysis of portal dosimetry pre-treatment quality assurance of hybrid IMRT breast treatment plans. JOURNAL OF RADIOTHERAPY IN PRACTICE 2020. [DOI: 10.1017/s1460396920000072] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
AbstractBackground:The purpose of this study is to evaluate the effectiveness and sensitivity of the Varian portal dosimetry (PD) system as a quality assurance (QA) tool for breast intensity-modulated radiation therapy (IMRT) treatment plans.Materials and methods:Four hundred portal dose images from 200 breast cancer patient IMRT treatment plans were analysed. The images were obtained using Varian PortalVision electronic portal imaging devices (EPIDs) on Varian TrueBeam Linacs. Three patient plans were selected, and the multi-leaf collimator (MLC) positions were randomly altered by a mean of 0·5, 1, 1·5 and 2 mm with a standard deviation of 0·1 mm on 50, 75 and 100% of control points. Using the improved/global gamma calculation algorithm with a low-dose threshold of 10% in the EPID, the change in gamma passing rates for 3%/3 mm, 2%/2 mm and 1%/1 mm criterion was analysed as a function of the introduced error. The changes in the dose distributions of clinical target volume and organ at risk due to MLC positioning errors were also analysed.Results:Symmetric and asymmetric breast or chest wall plan fields are different in delivery as well as in the QA. An average gamma passing rate of 99·8 ± 0·5 is presented for 3%/3 mm symmetric plans and 96·9 ± 4·5 is presented for 3%/3 mm asymmetric plans. An average gamma passing rate of 98·4 ± 4·3 is presented for 2%/2 mm symmetric plans and 89·7 ± 9·5 is presented for 2%/2 mm asymmetric plans. A large-induced error in MLC positioning (2·0 mm, 100% of control points) results in an insignificant change in dose that would be delivered to the patient. However, EPID portal dosimetry is sensitive enough to detect even the slightest change in MLC positioning error (0·5 mm, 50% of control points).Conclusions:Stricter pre-treatment QA action levels can be established for breast IMRT plans utilising EPID. For improved sensitivity, a multigamma criteria approach is recommended. The PD tool is sensitive enough to detect MLC positioning errors that contribute to even insignificant dose changes.
Collapse
|
26
|
Ashraf MR, Bruza P, Pogue BW, Nelson N, Williams BB, Jarvis LA, Gladstone DJ. Optical imaging provides rapid verification of static small beams, radiosurgery, and VMAT plans with millimeter resolution. Med Phys 2019; 46:5227-5237. [PMID: 31472093 DOI: 10.1002/mp.13797] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2019] [Revised: 08/09/2019] [Accepted: 08/10/2019] [Indexed: 11/07/2022] Open
Abstract
PURPOSE We demonstrate the feasibility of optical imaging as a quality assurance tool for static small beamlets, and pretreatment verification tool for radiosurgery and volumetric-modulated arc therapy (VMAT) plans. METHODS Small static beams and clinical VMAT plans were simulated in a treatment planning system (TPS) and delivered to a cylindrical tank filled with water-based liquid scintillator. Emission was imaged using a blue-sensitive, intensified CMOS camera time-gated to the linac pulses. For static beams, percentage depth and cross beam profiles of projected intensity distribution were compared to TPS data. Two-dimensional (2D) gamma analysis was performed on all clinical plans, and the technique was tested for sensitivity against common errors (multileaf collimator position, gantry angle) by inducing deliberate errors in the VMAT plans control points. The technique's detection limits for spatial resolution and the smallest number of control points that could be imaged reliably were also tested. The sensitivity to common delivery errors was also compared against a commercial 2.5D diode array dosimeter. RESULTS A spatial resolution of 1 mm was achieved with our imaging setup. The optical projected percentage depth intensity profiles agreed to within 2% relative to the TPS data for small static square beams (5, 10, and 50 mm2 ). For projected cross beam profiles, a gamma pass rate >99% was achieved for a 3%/1 mm criteria. All clinical plans passed the 3%/3 mm criteria with >95% passing rate. A static 5 mm beam with 20 Monitor Units could be measured with an average percent difference of 5.5 ± 3% relative to the TPS. The technique was sensitive to multileaf collimator errors down to 1 mm and gantry angle errors of 1°. CONCLUSIONS Optical imaging provides ample spatial resolution for imaging small beams. The ability to faithfully image down to 20 MU of 5 mm, 6 MV beamlets prove the ability to perform quality assurance for each control point within dynamic plans. The technique is sensitive to small offset errors in gantry angles and multileaf collimator (MLC) leaf positions, and at certain scenario, it exhibits higher sensitivity than a commercial 2.5D diode array.
Collapse
Affiliation(s)
| | - Petr Bruza
- Thayer School of Engineering, Dartmouth College Hanover, Hanover, NH, 03755, USA
| | - Brian W Pogue
- Thayer School of Engineering, Dartmouth College Hanover, Hanover, NH, 03755, USA.,Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, NH, 03756, USA
| | - Nathan Nelson
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, NH, 03756, USA
| | - Benjamin B Williams
- Thayer School of Engineering, Dartmouth College Hanover, Hanover, NH, 03755, USA.,Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, NH, 03756, USA.,Department of Medicine, Geisel School of Medicine, Dartmouth College Hanover, Hanover, NH, 03755, USA
| | - Lesley A Jarvis
- Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, NH, 03756, USA.,Department of Medicine, Geisel School of Medicine, Dartmouth College Hanover, Hanover, NH, 03755, USA
| | - David J Gladstone
- Thayer School of Engineering, Dartmouth College Hanover, Hanover, NH, 03755, USA.,Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, NH, 03756, USA.,Department of Medicine, Geisel School of Medicine, Dartmouth College Hanover, Hanover, NH, 03755, USA
| |
Collapse
|
27
|
Lam D, Zhang X, Li H, Deshan Y, Schott B, Zhao T, Zhang W, Mutic S, Sun B. Predicting gamma passing rates for portal dosimetry‐based IMRT QA using machine learning. Med Phys 2019; 46:4666-4675. [DOI: 10.1002/mp.13752] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2019] [Revised: 07/29/2019] [Accepted: 07/30/2019] [Indexed: 12/12/2022] Open
Affiliation(s)
- Dao Lam
- Department of Radiation Oncology Washington University School of Medicine 4921 Parkview Place, Campus Box 8224 St. Louis MO 63110USA
| | - Xizhe Zhang
- School of Computer Science and Engineering Northeastern University Shenyang Liaoning 110819China
| | - Harold Li
- Department of Radiation Oncology Washington University School of Medicine 4921 Parkview Place, Campus Box 8224 St. Louis MO 63110USA
| | - Yang Deshan
- Department of Radiation Oncology Washington University School of Medicine 4921 Parkview Place, Campus Box 8224 St. Louis MO 63110USA
| | - Brayden Schott
- Department of Radiation Oncology Washington University School of Medicine 4921 Parkview Place, Campus Box 8224 St. Louis MO 63110USA
| | - Tianyu Zhao
- Department of Radiation Oncology Washington University School of Medicine 4921 Parkview Place, Campus Box 8224 St. Louis MO 63110USA
| | - Weixiong Zhang
- Department of Computer Science and Engineering Washington University One Brookings Drive, CampusBox 1045 St. Louis MO 63130USA
| | - Sasa Mutic
- Department of Radiation Oncology Washington University School of Medicine 4921 Parkview Place, Campus Box 8224 St. Louis MO 63110USA
| | - Baozhou Sun
- Department of Radiation Oncology Washington University School of Medicine 4921 Parkview Place, Campus Box 8224 St. Louis MO 63110USA
| |
Collapse
|
28
|
Yedekci Y, Biltekin F, Ozyigit G. Feasibility study of an electronic portal imaging based in vivo dose verification system for prostate stereotactic body radiotherapy. Phys Med 2019; 64:204-209. [DOI: 10.1016/j.ejmp.2019.07.008] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/02/2019] [Revised: 07/03/2019] [Accepted: 07/11/2019] [Indexed: 11/16/2022] Open
|
29
|
Pogson E, Arumugam S, Hansen C, Currie M, Blake S, Roberts N, Carolan M, Vial P, Alharthi T, Holloway L, Thwaites D. Comparison of multi-institutional pre-treatment verification for VMAT of nasopharynx with delivery errors. Phys Med 2018; 53:25-31. [DOI: 10.1016/j.ejmp.2018.07.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2018] [Revised: 07/19/2018] [Accepted: 07/21/2018] [Indexed: 10/28/2022] Open
|
30
|
Park SY, Park JM, Kim JI, Lee S, Choi CH. Validation of new transmission detector transmission factors for online dosimetry: an experimental study. Radiat Oncol 2018; 13:156. [PMID: 30143012 PMCID: PMC6109263 DOI: 10.1186/s13014-018-1106-y] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2018] [Accepted: 08/20/2018] [Indexed: 01/14/2023] Open
Abstract
Background The demand for dose verification during treatment has risen with the increasing use of intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) in modern radiation therapy. This study aims to validate the transmission factors of a new transmission detector, the Dolphin online monitoring system (IBA Dosimetry, Schwarzenbruck, Germany), for clinical use. Methods The transmission factors of the Dolphin detector were evaluated using 6 MV, 6 flattening filter free (FFF), 10 MV, and 10 FFF clinical beams from a TrueBeam STx linear accelerator system. Two-dimensional (2D) dose distributions were measured through portal dosimetry with and without Dolphin to derive the transmission factors. The measurements were performed using 10 IMRT and 10 VMAT treatment plans. The transmission factors were calculated using a non-negative least squares problem solver for the 2D dose matrix. Normalized plans were generated using the derived transmission factors. Patient-specific quality assurance with normalized plans was performed using portal dosimetry and an ArcCheck detector to verify the transmission factors. The gamma passing rates were calculated for the 2%/2 mm and 1%/1 mm criteria. Results The transmission factors for the 6 MV, 6 FFF, 10 MV, and 10 FFF beams, were 0.878, 0.824, 0.913, and 0.883, respectively. The average dose difference between the original plan without Dolphin and the normalized plan with Dolphin was less than 1.8% for all measurements. The mean passing rates of the gamma evaluation were 98.1 ± 2.1 and 82.9 ± 12.6 for the 2%/2 mm and 1%/1 mm criteria, respectively, for portal dosimetry of the original plan. In the case of the portal dosimetry of the normalized plan, the mean passing rates of the gamma evaluation were 97.2 ± 2.8 and 79.1 ± 14.8 for the 2%/2 mm and 1%/1 mm criteria, respectively. Conclusions The Dolphin detector can be used for online dosimetry when valid transmission factors are applied to the clinical plan.
Collapse
Affiliation(s)
- So-Yeon Park
- Department of Radiation Oncology, Veterans Health Service Medical Center, Seoul, Republic of Korea.,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea
| | - Jong Min Park
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea.,Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea.,Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea
| | - Jung-In Kim
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea.,Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea.,Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea
| | - Sungyoung Lee
- Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea
| | - Chang Heon Choi
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea. .,Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea. .,Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea.
| |
Collapse
|
31
|
Urso P, Lorusso R, Marzoli L, Corletto D, Imperiale P, Pepe A, Bianchi L. Practical application of Octavius ® -4D: Characteristics and criticalities for IMRT and VMAT verification. J Appl Clin Med Phys 2018; 19:517-524. [PMID: 30009564 PMCID: PMC6123102 DOI: 10.1002/acm2.12412] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2018] [Revised: 03/28/2018] [Accepted: 06/07/2018] [Indexed: 11/12/2022] Open
Abstract
Octavius®‐4D is a very effective device in radiotherapy treatment quality assurance (QA), due to its simple set‐up and analysis package. However, even if it is widely used, its main characteristics and criticalities were only partially investigated. Taking start from its commissioning, the aim of this work was to study the main dependencies of the device response. The outcome dependence was studied comparing results by different delivery techniques [Intensity Modulated Radiation Therapy, IMRT (n = 29) and RapidArc, RA (n = 15)], anatomical regions [15 head/neck, 19 pelvis and 10 pancreas] and linear accelerators [DHX (n = 14) and Trilogy (n = 30)]. Moreover, the agreement dependency on the section of the phantom was assessed. Plan evaluations obtained by 2D, 3D, and volumetric γ‐index (both local and global) were also compared. Generally, high dose gradient resulted critically managed by the assembly, with a smoother effect in RA technique. Worse agreements emerged in the 2D γ‐index vs those of 3D and volumetric (P < 0.001), that were instead statistically comparable in global metric (P > 0.300). Volumetric plan evaluation was coherent with the average of passing rates on the 3 phantom axes (r ≥ 0.9), but transversal section provided best agreements vs sagittal and coronal ones (P < 0.050). The three studied districts furnished comparable results (P > 0.050) while the two LINACs provided different agreements (P < 0.005). The study pointed out that the phantom transversal section better fits the planned dose distribution, so this should be accounted when a two‐dimensional evaluation is needed. Moreover, the major reliability of the 3D metric with respect to the 2D one, as it better agrees with the dosimetric evaluation on the whole volume, suggests that it should be preferred in a two‐dimensional evaluation. Better agreements, obtained with RA vs IMRT technique, confirm that Octavius®‐4D is specifically conceived for rotational delivery. Lastly, the assembly resulted sensitive to different technology.
Collapse
Affiliation(s)
- Patrizia Urso
- Department of Medical Physics, A.S.S.T. Valle Olona, Busto Arsizio, Italy
| | - Rita Lorusso
- Department of Medical Physics, A.S.S.T. Valle Olona, Busto Arsizio, Italy
| | - Luca Marzoli
- Department of Medical Physics, A.S.S.T. Valle Olona, Busto Arsizio, Italy
| | - Daniela Corletto
- Department of Medical Physics, A.S.S.T. Valle Olona, Busto Arsizio, Italy
| | - Paolo Imperiale
- Department of Medical Physics, A.S.S.T. Valle Olona, Busto Arsizio, Italy
| | - Annalisa Pepe
- Department of Medical Physics, A.S.S.T. Valle Olona, Busto Arsizio, Italy
| | - Lorenzo Bianchi
- Department of Medical Physics, A.S.S.T. Valle Olona, Busto Arsizio, Italy
| |
Collapse
|
32
|
Zhang D, Wang B, Zhang G, Ma C, Deng X. Comparison of 3D and 2D gamma passing rate criteria for detection sensitivity to IMRT delivery errors. J Appl Clin Med Phys 2018; 19:230-238. [PMID: 29905004 PMCID: PMC6036388 DOI: 10.1002/acm2.12389] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2018] [Revised: 05/07/2018] [Accepted: 05/24/2018] [Indexed: 11/11/2022] Open
Abstract
This study compared three‐dimensional (3D) and two‐dimensional (2D) percentage gamma passing rates (%GPs) for detection sensitivity to IMRT delivery errors and investigated the correlation between two kinds of %GP. Eleven prostate IMRT cases were selected, and errors in multileaf collimator (MLC) bank sag, MLC leaf traveling, and machine output were simulated by recalculating the dose distributions in patients. 2D doses were extracted from the 3D doses at the isocenter position. The 3D and 2D %GPs with different gamma criteria were then obtained by comparing the recalculated and original doses in specific regions of interest (ROI), such as the whole body, the planning target volume (PTV), the bladder, and the rectum. The sensitivities to simulated errors of the two types of %GP were compared, and the correlation between the 2D and 3D %GPs for different ROIs were analyzed. For the whole‐body evaluation, both the 2D and 3D %GPs with the 3%/3 mm criterion were above 90% for all tested MLC errors and for MU deviations up to 4%, and the 3D %GP was higher than the 2D %GP. In organ‐specific evaluations, the PTV‐specific 2D and 3D %GP gradients were −4.70% and −5.14% per millimeter of the MLC traveling error, and −17.79% and −20.50% per percentage of MU error, respectively. However, a stricter criterion (2%/1 mm) was needed to detect the tested MLC sag error. The Pearson correlation analysis showed a significant strong correlation (r > 0.8 and P < 0.001) between the 2D and 3D %GPs in the whole body and PTV‐specific gamma evaluations. The whole‐body %GP with the 3%/3 mm criterion was inadequate to detect the tested MLC and MU errors, and a stricter criterion may be needed. The PTV‐specific gamma evaluation helped to improve the sensitivity of the error detection, especially using the 3D GP%.
Collapse
Affiliation(s)
- Dandan Zhang
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China.,School of Physics, Sun Yat-sen University, Guangzhou, China
| | - Bin Wang
- Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA, USA
| | - Guangshun Zhang
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Charlie Ma
- Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA, USA
| | - Xiaowu Deng
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China.,School of Physics, Sun Yat-sen University, Guangzhou, China
| |
Collapse
|
33
|
Dosimetric variations in calculation grid size in prostate VMAT: a dose-volume histogram analysis using the Gaussian error function. JOURNAL OF RADIOTHERAPY IN PRACTICE 2018. [DOI: 10.1017/s1460396917000619] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AbstractBackgroundVarying the calculation grid size can change the results of dose-volume and radiobiological parameters in a treatment plan, and therefore has an impact on the treatment planning quality assurance.PurposeThis study investigated the dosimetric influence of the calculation grid size variation in the prostate volumetric modulated arc therapy (VMAT) plan.Methods and materialsDose distributions of 10 prostate VMAT plans were acquired using calculation grid sizes of 1–5 mm. Dose-volume histogram (DVH) analysis was carried out to determine the dose-volume variation corresponding to the grid size change using the Gaussian error function (GEF). At the same time, dose-volume points, dose-volume parameters and radiobiological parameters were calculated based on DVHs of targets and organs at risk (OARs) for each grid size.ResultsComparing percentage variations of GEF parameters between the planning target volume (PTV) and clinical target volume (CTV), GEF parameters of the PTV were found varied more significantly than the CTV. This resulted in larger variations of dose-volume (%ΔCI=40·02 versus 13·55%, %ΔHI=12·45 versus 2·93% and %ΔGI=0·22 versus 0·06%) and radiobiological parameters (%ΔTCP=0·61 versus 0·25% and %ΔEUD=2·11 versus 0·26%) of the PTV compared with CTV. For OARs, the rectal wall showed a larger dose-volume variation than the rectum. However, similar dose-volume variation due to grid size change was not found in the bladder, bladder wall and femur.ConclusionsKnowing the dosimetric variation in this study is important to the radiotherapy staff in the quality assurance for the prostate VMAT planning.
Collapse
|
34
|
Wootton LS, Nyflot MJ, Chaovalitwongse WA, Ford E. Error Detection in Intensity-Modulated Radiation Therapy Quality Assurance Using Radiomic Analysis of Gamma Distributions. Int J Radiat Oncol Biol Phys 2018; 102:219-228. [PMID: 30102197 DOI: 10.1016/j.ijrobp.2018.05.033] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2017] [Revised: 04/10/2018] [Accepted: 05/13/2018] [Indexed: 10/16/2022]
Abstract
PURPOSE To improve the detection of errors in intensity-modulated radiation therapy (IMRT) with a novel method that uses quantitative image features from radiomics to analyze gamma distributions generated during patient specific quality assurance (QA). METHODS AND MATERIALS One hundred eighty-six IMRT beams from 23 patient treatments were delivered to a phantom and measured with electronic portal imaging device dosimetry. The treatments spanned a range of anatomic sites; half were head and neck treatments, and the other half were drawn from treatments for lung and rectal cancers, sarcoma, and glioblastoma. Planar gamma distributions, or gamma images, were calculated for each beam using the measured dose and calculated doses from the 3-dimensional treatment planning system under various scenarios: a plan without errors and plans with either simulated random or systematic multileaf collimator mispositioning errors. The gamma images were randomly divided into 2 sets: a training set for model development and testing set for validation. Radiomic features were calculated for each gamma image. Error detection models were developed by training logistic regression models on these radiomic features. The models were applied to the testing set to quantify their predictive utility, determined by calculating the area under the curve (AUC) of the receiver operator characteristic curve, and were compared with traditional threshold-based gamma analysis. RESULTS The AUC of the random multileaf collimator mispositioning model on the testing set was 0.761 compared with 0.512 for threshold-based gamma analysis. The AUC for the systematic mispositioning model was 0.717 versus 0.660 for threshold-based gamma analysis. Furthermore, the models could discriminate between the 2 types of errors simulated here, exhibiting AUCs of approximately 0.5 (equivalent to random guessing) when applied to the error they were not designed to detect. CONCLUSIONS The feasibility of error detection in patient-specific IMRT QA using radiomic analysis of QA images has been demonstrated. This methodology represents a substantial step forward for IMRT QA with improved sensitivity and specificity over current QA methods and the potential to distinguish between different types of errors.
Collapse
Affiliation(s)
- Landon S Wootton
- Department of Radiation Oncology, University of Washington School of Medicine, Seattle, Washington.
| | - Matthew J Nyflot
- Department of Radiation Oncology, University of Washington School of Medicine, Seattle, Washington; Department of Radiology, University of Washington School of Medicine, Seattle, Washington
| | - W Art Chaovalitwongse
- Department of Radiology, University of Washington School of Medicine, Seattle, Washington; Department of Industrial Engineering, University of Arkansas, Fayetteville, Arkansas
| | - Eric Ford
- Department of Radiation Oncology, University of Washington School of Medicine, Seattle, Washington
| |
Collapse
|
35
|
Wang Y, Pang X, Feng L, Wang H, Bai Y. Correlation between gamma passing rate and complexity of IMRT plan due to MLC position errors. Phys Med 2018; 47:112-120. [PMID: 29609812 DOI: 10.1016/j.ejmp.2018.03.003] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/26/2017] [Revised: 02/13/2018] [Accepted: 03/04/2018] [Indexed: 10/17/2022] Open
Abstract
PURPOSE This study evaluates the correlation between the susceptibility of the γ passing rate of IMRT plans to the multi-leaf collimator (MLC) position errors and a quantitative plan complexity metric. METHODS Twenty patients were selected for this study. For each patient, two IMRT plans were generated using sliding window and step-&-shoot techniques, respectively. Modulation complexity score (MCS) was calculated for all IMRT plans, and symmetric MLC leaf bank errors, ranging from 0.3 mm to 1 mm, were introduced. Original and modified plans were delivered using Varian's Clinac iX. The obtained dose distribution using ArcCHECK was then compared with the TPS calculated dose distribution of the original plans. 3D gamma analysis was performed for each verification with passing criteria of 2%/2 mm. The γ passing rate decreasing gradient were calculated to evaluate relationship between variation of γ passing rate due to MLC errors and complexity. RESULTS A linear regression analysis was applied between γ gradient and complexity, and the results showed a linear correlation (R2 = 0.81 and 0.82 for open and closed MLC error types, respectively) indicating the more complex plans are more susceptible to MLC leaf bank errors. Meanwhile, correlation of re-normalized γ passing rate and complexity for all errors scenarios also presented a strong correlation (r > 0.75). CONCLUSION The statistics results revealed variation relationship of dosimetry robust of plans with various complexities to MLC errors. Our results also suggested that the observed susceptibility is independent of the delivery techniques.
Collapse
Affiliation(s)
- Yewei Wang
- Department of Radiation Physics, The Affiliated Tumor Hospital of Harbin Medical University, Harbin, China
| | - Xueying Pang
- Department of Oncology, First Affiliated Hospital, Heilongjiang University of Chinese Medicine, Harbin, China
| | - Lina Feng
- Department of Radiation Physics, The Affiliated Tumor Hospital of Harbin Medical University, Harbin, China
| | - Helong Wang
- Department of Radiation Physics, The Affiliated Tumor Hospital of Harbin Medical University, Harbin, China
| | - Yanling Bai
- Department of Radiation Physics, The Affiliated Tumor Hospital of Harbin Medical University, Harbin, China.
| |
Collapse
|
36
|
Dose-volume and radiobiological dependence on the calculation grid size in prostate VMAT planning. Med Dosim 2018; 43:383-389. [PMID: 29373184 DOI: 10.1016/j.meddos.2017.12.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2017] [Revised: 09/27/2017] [Accepted: 12/15/2017] [Indexed: 02/03/2023]
Abstract
This study evaluated the effects of dose-volume and radiobiological dependence on the calculation grid size in prostate volumetric-modulated arc therapy (VMAT) planning. Ten patients with prostate cancer were selected for this retrospective treatment planning study. Prostate VMAT plans were created for the patients using the 6 MV photon beam produced by a Varian TrueBEAM linac with the calculation grid size equal to 1, 2, 2.5, 3, 4, and 5 mm. Dose-volume histograms (DVHs) of targets and organs at risk were generated for different grid sizes. We calculated the radiobiological parameters of the tumor control probability (TCP) of clinical target volume (CTV) and planning target volume (PTV), and the normal tissue complication probability (NTCP) of organs at risk (rectal wall, rectum, bladder wall, bladder, left femur, and right femur). The homogeneity, conformity, and gradient indexes of CTV and PTV were calculated for different grid sizes. The TCP of PTV was found decreasing with a rate of 0.06%/mm when the calculation grid size increased from 1 to 5 mm. On the other hand, both NTCPs of rectal wall and rectum were found decreasing with rates of 0.03%/mm and 0.05%/mm, respectively, with an increase of grid size. The homogeneity index of PTV increased with a rate of 0.57/mm of the calculation grid size, whereas the conformity index of PTV decreased with a rate of 0.0075/mm. The gradient index of PTV was found increasing with a rate equal to 0.05/mm. In prostate VMAT planning, variations of dose-volume and radiobiological parameters with calculation grid size on PTV, rectal wall, and rectum were more significant than those of CTV and other organs at risk such as bladder wall, bladder, and femurs. Results in this study are important in the treatment planning quality assurance when the calculation grid size is varied to compromise a shorter dose computing time.
Collapse
|
37
|
Bruschi A, Esposito M, Pini S, Ghirelli A, Zatelli G, Russo S. How the detector resolution affects the clinical significance of SBRT pre-treatment quality assurance results. Phys Med 2017; 49:129-134. [PMID: 29203119 DOI: 10.1016/j.ejmp.2017.11.012] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/21/2017] [Revised: 09/22/2017] [Accepted: 11/15/2017] [Indexed: 10/18/2022] Open
Abstract
PURPOSE Aim of this work was to study how the detector resolution can affect the clinical significance of SBRT pre-treatment volumetric modulated arc therapy (VMAT) verification results. METHODS Three detectors (PTW OCTAVIUS 4D 729, 1500 and 100 SRS) used in five configurations with different resolution were compared: 729, 729 merged, 1500, 1500 merged and 1000 SRS. Absolute local gamma passing rates of 3D pre-treatment quality assurance (QA) were evaluated for 150 dose distributions in 30 plans. Five different kinds of error were introduced in order to establish the detection sensitivity of the three devices. Percentage dosimetric differences were evaluated between planned dosevolume histogram (DVH) and patients' predicted DVH calculated by PTW DVH 4D® software. RESULTS The mean gamma passing rates and the standard deviations were 92.4% ± 3.7%, 94.6% ± 1.8%, 95.3% ± 4.2%, 97.4% ± 2.5% and 97.6% ± 1.4 respectively for 729, 729 merged, 1500, 1500 merged and 1000 SRS with 2% local dose/2mm criterion. The same trend was found on the sensitivity analysis: using a tight gamma analysis criterion (2%L/1mm) only the 1000 SRS detected every kind of error, while 729 and 1500 merged detected three and four kinds of error respectively. Regarding dose metrics extracted from DVH curves, D50% was within the tolerance level in more than 90% of cases only for the 1000 SRS. CONCLUSIONS The detector resolution can significantly affect the clinical significance of SBRT pre-treatment verification results. The choice of a detector with resolution suitable to the investigated field size is of main importance to avoid getting false positive.
Collapse
Affiliation(s)
| | - M Esposito
- Medical Physics Unit, Azienda USL Toscana Centro, Florence, Italy
| | - S Pini
- Medical Physics Unit, Azienda USL Toscana Centro, Florence, Italy
| | - A Ghirelli
- Medical Physics Unit, Azienda USL Toscana Centro, Florence, Italy
| | - G Zatelli
- Medical Physics Unit, Azienda USL Toscana Centro, Florence, Italy
| | - S Russo
- Medical Physics Unit, Azienda USL Toscana Centro, Florence, Italy.
| |
Collapse
|
38
|
Lim-Reinders S, Keller BM, Al-Ward S, Sahgal A, Kim A. Online Adaptive Radiation Therapy. Int J Radiat Oncol Biol Phys 2017; 99:994-1003. [DOI: 10.1016/j.ijrobp.2017.04.023] [Citation(s) in RCA: 81] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2016] [Accepted: 04/14/2017] [Indexed: 10/19/2022]
|
39
|
Morrison CT, Symons KL, Woodings SJ, House MJ. Verification of junction dose between VMAT arcs of total body irradiation using a Sun Nuclear ArcCHECK phantom. J Appl Clin Med Phys 2017; 18:177-182. [PMID: 29082594 PMCID: PMC5689932 DOI: 10.1002/acm2.12208] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2017] [Revised: 08/09/2017] [Accepted: 09/11/2017] [Indexed: 11/06/2022] Open
Abstract
A volumetric modulated arc therapy (VMAT) approach to total body irradiation (TBI) has recently been introduced at our institution. The planning target volume (PTV) is divided into separate sub-volumes, each being treated with 2 arcs with their own isocentre. Pre-treatment quality assurance of beams is performed on a Sun Nuclear ArcCHECK diode array. Measurement of junction regions between VMAT arcs with separate isocentres has previously been performed with point dose ionization chamber measurements, or with films. Translations of the ArcCHECK with respect to a known distance between the adjacent isocentres of two arcs, which are repeated with the ArcCHECK in an inverted position, allows the recording of a junction dose map. A 3%/3 mm global gamma analysis (10% threshold) pass rate for arc junctions were comparable to their component arcs. Dose maps of junction regions between adjacent arcs with different isocentres can be readily measured on a Sun Nuclear ArcCHECK diode array.
Collapse
Affiliation(s)
- Colm T Morrison
- Department of Radiation Oncology, Genesis Cancer Care WA, Fiona Stanley Hospital, 11 Robin Warren Drive, Murdoch, 6150, Western Australia.,School of Physics, The University of Western Australia, 35 Stirling Highway, Crawley, 6009, Western Australia
| | - Kirsty L Symons
- Department of Radiation Oncology, Genesis Cancer Care WA, Fiona Stanley Hospital, 11 Robin Warren Drive, Murdoch, 6150, Western Australia
| | - Simon J Woodings
- Department of Radiation Oncology, Genesis Cancer Care WA, Fiona Stanley Hospital, 11 Robin Warren Drive, Murdoch, 6150, Western Australia.,School of Physics, The University of Western Australia, 35 Stirling Highway, Crawley, 6009, Western Australia
| | - Michael J House
- School of Physics, The University of Western Australia, 35 Stirling Highway, Crawley, 6009, Western Australia
| |
Collapse
|
40
|
Fuangrod T, Greer PB, Zwan BJ, Barnes MP, Lehmann J. A novel and independent method for time-resolved gantry angle quality assurance for VMAT. J Appl Clin Med Phys 2017; 18:134-142. [PMID: 28703451 PMCID: PMC5874941 DOI: 10.1002/acm2.12129] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2017] [Revised: 05/21/2017] [Accepted: 06/05/2017] [Indexed: 11/30/2022] Open
Abstract
Volumetric‐modulated arc therapy (VMAT) treatment delivery requires three key dynamic components; gantry rotation, dose rate modulation, and multi‐leaf collimator motion, which are all simultaneously varied during the delivery. Misalignment of the gantry angle can potentially affect clinical outcome due to the steep dose gradients and complex MLC shapes involved. It is essential to develop independent gantry angle quality assurance (QA) appropriate to VMAT that can be performed simultaneously with other key VMAT QA testing. In this work, a simple and inexpensive fully independent gantry angle measurement methodology was developed that allows quantitation of the gantry angle accuracy as a function of time. This method is based on the analysis of video footage of a “Double dot” pattern attached to the front cover of the linear accelerator that consists of red and green circles printed on A4 paper sheet. A standard mobile phone is placed on the couch to record the video footage during gantry rotation. The video file is subsequently analyzed and used to determine the gantry angle from each video frame using the relative position of the two dots. There were two types of validation tests performed including the static mode with manual gantry angle rotation and dynamic mode with three complex test plans. The accuracy was 0.26° ± 0.04° and 0.46° ± 0.31° (mean ± 1 SD) for the static and dynamic modes, respectively. This method is user friendly, cost effective, easy to setup, has high temporal resolution, and can be combined with existing time‐resolved method for QA of MLC and dose rate to form a comprehensive set of procedures for time‐resolved QA of VMAT delivery system.
Collapse
Affiliation(s)
- Todsaporn Fuangrod
- Department of Radiation Oncology, Calvary Mater Newcastle Hospital, Newcastle, NSW, Australia
| | - Peter B Greer
- Department of Radiation Oncology, Calvary Mater Newcastle Hospital, Newcastle, NSW, Australia.,School of Mathematical and Physics Sciences, Faculty of Science and IT, the University of Newcastle, Newcastle, NSW, Australia
| | - Benjamin J Zwan
- School of Mathematical and Physics Sciences, Faculty of Science and IT, the University of Newcastle, Newcastle, NSW, Australia.,Central Coast Cancer Centre, Gosford Hospital, Gosford, NSW, Australia
| | - Michael P Barnes
- Department of Radiation Oncology, Calvary Mater Newcastle Hospital, Newcastle, NSW, Australia.,School of Mathematical and Physics Sciences, Faculty of Science and IT, the University of Newcastle, Newcastle, NSW, Australia.,School of Medical Radiation Sciences, University of Newcastle, Newcastle, NSW, Australia
| | - Joerg Lehmann
- Department of Radiation Oncology, Calvary Mater Newcastle Hospital, Newcastle, NSW, Australia.,School of Mathematical and Physics Sciences, Faculty of Science and IT, the University of Newcastle, Newcastle, NSW, Australia
| |
Collapse
|
41
|
The sensitivity of gamma index analysis to detect multileaf collimator (MLC) positioning errors using Varian TrueBeam EPID and ArcCHECK for patient-specific prostate volumetric-modulated arc therapy (VMAT) quality assurance. JOURNAL OF RADIOTHERAPY IN PRACTICE 2017. [DOI: 10.1017/s1460396917000425] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
AbstractBackgroundDue to the increased degree of modulation and complexity of volumetric-modulated arc therapy (VMAT) plans, it is necessary to have a pre-treatment patient-specific quality assurance (QA) programme. The gamma index is commonly used to quantitatively compare two dose distributions. In this study we investigated the sensitivity of single- and multi-gamma criteria techniques to detect multileaf collimator (MLC) positioning errors using the Varian TrueBeam Electronic Portal Imaging DeviceTM (EPID) dosimetry and the ArcCHECKTM device.Materials and methodsAll active MLC positions of seven intact prostate patients VMAT plans were randomly changed with a mean value of 0.25, 0.5, 1 and 2 mm and a standard deviation of 0.1 mm on 25, 50, 75 and 100% of the control points. The change in gamma passing rates of six gamma criteria of 3%/3 mm, 3%/2 mm, 3%/1 mm, 2%/2 mm, 2%/1 mm and 1%/1 mm were analysed individually (single-gamma criterion) and as a group (multi-gamma criteria) as a function of the simulated errors. We used the improved and global gamma calculation algorithms with a low dose threshold of 10% in the EPID and ArcCHECK software, respectively. The changes in the planning target volume dose distributions and the organs at risk due to the MLC positioning errors were also studied.ResultsWhen 25, 50, 75 and 100% of the control points were modified by the introduction of the simulated errors, the smallest detectable errors with the EPID were 2, 1, 0.5 and 0.5 mm, respectively, using the multi-gamma criteria technique. Similarly for the single-gamma criteria technique errors as small as 2, 1, 1 and 1 mm applied to 25, 50, 75 and 100% of the control points, respectively, were detectable using a 2%/2 mm criterion. However, the smallest detectable errors with the ArcCHECK when using the multi-gamma criteria technique were 2, 2 and 1 mm when MLC errors were applied on 50, 75 and 100% of the control points. When only 25% of the control points were affected the ArcCHECK were unable to detect any of the errors applied. No noticeable difference was observed in the sensitivity using the single- or the multi-gamma criteria techniques with the ArcCHECK.ConclusionThe Varian TrueBeam EPID dosimetry shows a higher sensitivity in detecting MLC positioning errors compared with the ArcCHECK regardless of using the single- or the multi-gamma criteria techniques. Higher sensitivity was observed using the multi-gamma criteria technique compared with the single-criterion technique when using the EPID.
Collapse
|