1
|
Solou K, Solou AV, Tatani I, Lakoumentas J, Tserpes K, Megas P. Increased stability of short femoral stem through customized distribution of coefficient of friction in porous coating. Sci Rep 2024; 14:12243. [PMID: 38806607 PMCID: PMC11133419 DOI: 10.1038/s41598-024-63077-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Accepted: 05/24/2024] [Indexed: 05/30/2024] Open
Abstract
Stress shielding and aseptic loosening are complications of short stem total hip arthroplasty, which may lead to hardware failure. Stems with increased porosity toward the distal end were discovered to be effective in reducing stress shielding, however, there is a lack of research on optimized porous distribution in stem's coating. This study aimed to optimize the distribution of the coefficient of friction of a metaphyseal femoral stem, aiming for reducing stress shielding in the proximal area. A finite element analysis model of an implanted, titanium alloy short-tapered wedge stem featuring a porous coating made of titanium was designed to simulate a static structural analysis of the femoral stem's behavior under axial loading in Analysis System Mechanical Software. For computational feasibility, 500 combinations of coefficients of friction were randomly sampled. Increased strains in proximal femur were found in 8.4% of the models, which had decreased coefficients of friction in middle medial areas of porous coating and increased in lateral proximal and lateral and medial distal areas. This study reported the importance of the interface between bone and middle medial and distal lateral areas of the porous coating in influencing the biomechanical behavior of the proximal femur, and potentially reducing stress shielding.
Collapse
Affiliation(s)
- Konstantina Solou
- Department of Orthopaedic Surgery and Traumatology, School of Medicine, University of Patras, Patras, Greece.
| | - Anna Vasiliki Solou
- Department of Mechanical Engineering & Aeronautics, University of Patras, Patras, Greece
| | - Irini Tatani
- Department of Orthopaedic Surgery and Traumatology, School of Medicine, University of Patras, Patras, Greece
| | - John Lakoumentas
- Department of Medical Physics, School of Medicine, University of Patras, Patras, Greece
| | - Konstantinos Tserpes
- Department of Mechanical Engineering & Aeronautics, University of Patras, Patras, Greece
| | - Panagiotis Megas
- Department of Orthopaedic Surgery and Traumatology, School of Medicine, University of Patras, Patras, Greece
| |
Collapse
|
2
|
Krasilnikova O, Yakimova A, Ivanov S, Atiakshin D, Kostin AA, Sosin D, Shegay P, Kaprin AD, Klabukov I. Gene-Activated Materials in Regenerative Dentistry: Narrative Review of Technology and Study Results. Int J Mol Sci 2023; 24:16250. [PMID: 38003439 PMCID: PMC10671237 DOI: 10.3390/ijms242216250] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Revised: 10/26/2023] [Accepted: 10/30/2023] [Indexed: 11/26/2023] Open
Abstract
Treatment of a wide variety of defects in the oral and maxillofacial regions requires the use of innovative approaches to achieve best outcomes. One of the promising directions is the use of gene-activated materials (GAMs) that represent a combination of tissue engineering and gene therapy. This approach implies that biocompatible materials will be enriched with gene-carrying vectors and implanted into the defect site resulting in transfection of the recipient's cells and secretion of encoded therapeutic protein in situ. GAMs may be presented in various designs depending on the type of material, encoded protein, vector, and way of connecting the vector and the material. Thus, it is possible to choose the most suitable GAM design for the treatment of a particular pathology. The use of plasmids for delivery of therapeutic genes is of particular interest. In the present review, we aimed to delineate the principle of work and various designs of plasmid-based GAMs and to highlight results of experimental and clinical studies devoted to the treatment of periodontitis, jaw bone defects, teeth avulsion, and other pathologies in the oral and maxillofacial regions.
Collapse
Affiliation(s)
- Olga Krasilnikova
- National Medical Research Radiological Centre of the Ministry of Health of the Russian Federation, Koroleva St. 4, 249036 Obninsk, Russia
| | - Anna Yakimova
- A. Tsyb Medical Radiological Research Centre—Branch of the National Medical Research Radiological Centre of the Ministry of Health of the Russian Federation, Zhukov St. 10, 249031 Obninsk, Russia
| | - Sergey Ivanov
- A. Tsyb Medical Radiological Research Centre—Branch of the National Medical Research Radiological Centre of the Ministry of Health of the Russian Federation, Zhukov St. 10, 249031 Obninsk, Russia
- Department of Urology and Operative Nephrology, Patrice Lumumba Peoples’ Friendship University of Russia (RUDN University), Miklukho-Maklay St. 6, 117198 Moscow, Russia
| | - Dmitri Atiakshin
- Scientific and Educational Resource Center for Innovative Technologies of Immunophenotyping, Digital Spatial Profiling and Ultrastructural Analysis, Patrice Lumumba Peoples’ Friendship University of Russia (RUDN University), 117198 Moscow, Russia
| | - Andrey A. Kostin
- Department of Urology and Operative Nephrology, Patrice Lumumba Peoples’ Friendship University of Russia (RUDN University), Miklukho-Maklay St. 6, 117198 Moscow, Russia
| | - Dmitry Sosin
- Centre for Strategic Planning and Management of Biomedical Health Risks of the Federal Medical Biological Agency, 119121 Moscow, Russia
| | - Peter Shegay
- National Medical Research Radiological Centre of the Ministry of Health of the Russian Federation, Koroleva St. 4, 249036 Obninsk, Russia
| | - Andrey D. Kaprin
- National Medical Research Radiological Centre of the Ministry of Health of the Russian Federation, Koroleva St. 4, 249036 Obninsk, Russia
- Department of Urology and Operative Nephrology, Patrice Lumumba Peoples’ Friendship University of Russia (RUDN University), Miklukho-Maklay St. 6, 117198 Moscow, Russia
| | - Ilya Klabukov
- National Medical Research Radiological Centre of the Ministry of Health of the Russian Federation, Koroleva St. 4, 249036 Obninsk, Russia
- Department of Urology and Operative Nephrology, Patrice Lumumba Peoples’ Friendship University of Russia (RUDN University), Miklukho-Maklay St. 6, 117198 Moscow, Russia
- Obninsk Institute for Nuclear Power Engineering, National Research Nuclear University MEPhI, Studgorodok 1, 249039 Obninsk, Russia
| |
Collapse
|
3
|
Lin B, Lan Y, Lu Z, Xie S, Lin F, Weng Y, Feng E, Chen J. The compared study about femoral stem malalignment with or without the special curved rasp during DAA total hip arthroplasty. BMC Musculoskelet Disord 2023; 24:319. [PMID: 37087443 PMCID: PMC10122324 DOI: 10.1186/s12891-023-06409-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Accepted: 04/07/2023] [Indexed: 04/24/2023] Open
Abstract
OBJECTIVE To investigate whether the application of a curved rasp on the femoral side is effective in reducing the incidence of stem malalignment in total hip replacement with direct anterior approach (DAA-THA), followed by the analysis of the independent risk factors affecting stem malalignment. METHODS Retrospective analysis was carried out covering 160 patients undergoing DAA-THA from January 2019 to December 2021, with Tri-Lock (BPS, Depuy) stem applied in all 113 patients were screened according to inclusion and exclusion criteria. The data of gender, age, body mass index, preoperative diagnoses, Dorr classification, FAR ratio, pelvic morphology ratio, WOMAC scores, were analyzed to explore the independent factors influencing the malalignment of the femoral prosthesis implantation. Then data of patients were divided into group A and group B according to whether the curved rasp was taken during the operation. The chi-square test was performed to compare the incidence of femoral stem malalignment between the two groups. RESULTS There revealed two independent risk factors: BMI and FAR ratio that affected femoral stem malalignment. The increased BMI was associated with a higher probability of femoral stem malalignment (P<0.05), the probability of malalignment of femoral stem in FAR ratio<1 was 1.15 times higher than that in FAR>1(OR = 1.15, 95% CI: 1.03-1.28, P<0.05). Further grouping analysis showed that the incidence of femoral stem malalignment in patients with intraoperative application of curved rasp was 27%, while in patients without curved rasp, the incidence of femoral stem malalignment increased significantly to 48.7%(P<0.05). The placement angle of prosthesis in group A was significantly better than that in group B, especially mild femoral stem malalignment (0%) and severe femoral stem malalignment (2.70%), and the difference was statistically significant (P < 0.05). There found no significant difference in age, gander, intraoperative complications and last follow-up assessment of WOMAC scores between the two groups of patients. CONCLUSIONS In DAA-THA, BMI and FAR ratio act as the independent risk factors for femoral stem malalignment. Intraoperative use of a curved rasp significantly reduces the incidence of malalignment of the femoral stem.
Collapse
Affiliation(s)
- Bei Lin
- Department of Arthrosis Surgery, Fuzhou Second Hospital, Fuzhou, China
- The Department of Clinical Medicine, Fujian Medical University, Fuzhou, China
| | - Yiping Lan
- Department of Arthrosis Surgery, Fuzhou Second Hospital, Fuzhou, China
| | - Zhiming Lu
- Department of Arthrosis Surgery, Fuzhou Second Hospital, Fuzhou, China
- The Department of Clinical Medicine, Fujian Medical University, Fuzhou, China
| | - Shiwei Xie
- Department of Arthrosis Surgery, Fuzhou Second Hospital, Fuzhou, China
- The Department of Clinical Medicine, Fujian Medical University, Fuzhou, China
| | - Feitai Lin
- Department of Arthrosis Surgery, Fuzhou Second Hospital, Fuzhou, China
| | - Yan Weng
- Department of Arthrosis Surgery, Fuzhou Second Hospital, Fuzhou, China
| | - Eryou Feng
- Department of Arthrosis Surgery, Fuzhou Second Hospital, Fuzhou, China.
- The Department of Clinical Medicine, Fujian Medical University, Fuzhou, China.
- Fuzhou Second Hospital Affiliated to Xiamen University, Fuzhou, China.
| | - Jinhua Chen
- Follow-Up Center, Fujian Medical University Union Hospital, Fuzhou, China
| |
Collapse
|
4
|
Liu B, Lv Y, Li X, Liu Z, Zheng Y, Wen P, Liu N, Huo Y, Zhou F, Tian Y. Influence of different fixation modes on biomechanical conduction of 3D printed prostheses for treating critical diaphyseal defects of lower limbs: A finite element study. Front Surg 2022; 9:959306. [PMID: 36090321 PMCID: PMC9448880 DOI: 10.3389/fsurg.2022.959306] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Accepted: 08/04/2022] [Indexed: 11/15/2022] Open
Abstract
Background Applying 3D printed prostheses to repair diaphyseal defects of lower limbs has been clinically conducted in orthopedics. However, there is still no unified reference standard for which the prosthesis design and fixation mode are more conducive to appropriate biomechanical conduction. Methods We built five different types of prosthesis designs and fixation modes, from Mode I to Mode V. Finite element analysis (FEA) was used to study and compare the mechanical environments of overall bone-prosthesis structure, and the maximum stress concentration were recorded. Additionally, by comparing the maximum von Mises stress of bone, intramedullary (IM) nail, screw, and prosthesis with their intrinsic yield strength, the risk of fixation failure was further clarified. Results In the modes in which the prosthesis was fixed by an interlocking IM nail (Mode I and Mode IV), the stress mainly concentrated at the distal bone-prosthesis interface and the middle-distal region of nail. When a prosthesis with integrally printed IM nail and lateral wings was implanted (Mode II), the stress mainly concentrated at the bone-prosthesis junctional region. For cases with partially lateral defects, the prosthesis with integrally printed wings mainly played a role in reconstructing the structural integrity of bone, but had a weak role in sharing the stress conduction (Mode V). The maximum von Mises stress of both the proximal and distal tibia appeared in Mode III, which were 18.5 and 47.1 MPa. The maximum peak stress shared by the prosthesis, screws and IM nails appeared in Mode II, III and I, which were 51.8, 87.2, and 101.8 MPa, respectively. These peak stresses were all lower than the yield strength of the materials themselves. Thus, the bending and breakage of both bone and implants were unlikely to happen. Conclusion For the application of 3D printed prostheses to repair diaphyseal defects, different fixation modes will lead to the change of biomechanical environment. Interlocking IM nail fixation is beneficial to uniform stress conduction, and conducive to new bone regeneration in the view of biomechanical point. All five modes we established have reliable biomechanical safety.
Collapse
Affiliation(s)
- Bingchuan Liu
- Department of Orthopaedics, Peking University Third Hospital, Beijing, China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Peking University Third Hospital, Beijing, China
| | - Yang Lv
- Department of Orthopaedics, Peking University Third Hospital, Beijing, China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Peking University Third Hospital, Beijing, China
| | - Xingcai Li
- Department of Orthopaedics, Peking University Third Hospital, Beijing, China
| | - Zhongjun Liu
- Department of Orthopaedics, Peking University Third Hospital, Beijing, China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Peking University Third Hospital, Beijing, China
| | - Yufeng Zheng
- School of Materials Science and Engineering, Peking University, Beijing, China
| | - Peng Wen
- Department of Mechanical Engineering, Tsinghua University, Beijing, China
| | - Ning Liu
- R&D Center, AK Medical Co., Ltd., Beijing, China
| | - Yaping Huo
- R&D Center, AK Medical Co., Ltd., Beijing, China
| | - Fang Zhou
- Department of Orthopaedics, Peking University Third Hospital, Beijing, China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Peking University Third Hospital, Beijing, China
- Correspondence: Fang Zhou Yun Tian
| | - Yun Tian
- Department of Orthopaedics, Peking University Third Hospital, Beijing, China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Peking University Third Hospital, Beijing, China
- Correspondence: Fang Zhou Yun Tian
| |
Collapse
|
5
|
Hu J, Peng Y, Li J, Li M, Xiong Y, Xiao J, Zhang L, Tang P. Spatial Bridge Locking Fixator versus Traditional Locking Plates in Treating AO/OTA 32-A3.2 Fracture: Finite Element Analysis and Biomechanical Evaluation. Orthop Surg 2022; 14:1638-1648. [PMID: 35733286 PMCID: PMC9363740 DOI: 10.1111/os.13308] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Revised: 04/16/2022] [Accepted: 04/16/2022] [Indexed: 11/28/2022] Open
Abstract
Objective To compare the biomechanical behaviors of the spatial bridge locking fixator (SBLF), single locking plate (SP), and double locking plate (DP) for AO/OTA 32‐A3.2 fractures using finite element analysis and biomechanical tests. Methods Axial loading of 700 N was conducted on the AO/OTA 32‐A3.2 model via finite element analysis. The von Mises stress and the interfragmentary movement (IFM) were comparatively analyzed in the three configurations above. On the mechanical tester, axial and torsional loading of 30 synthetic femurs (five specimens of each configuration for each test at random) was performed, and the interfragmentary movement, torsion angle, stiffness, and ultimate load were recorded and analyzed. Results The finite element analysis (FEA) results showed that the von Mises stress of the spatial bridge locking fixator (SBLF) was lower than that of the single locking plate (SP) and higher than that of the double locking plate (DP). At 700 N, the axial IFMs were 0.15–0.38 mm (SBLF), 0.03–0.84 mm (SP), and 0.02–0.07 mm (DP). The biomechanical experiment indicated that the axial interfragmentary movements (IFMs) were 0.44 ± 0.23 mm (SBLF), 1.02 ± 0.40 mm (SP), and 0.07 ± 0.07 mm (DP) (p < 0.001). The axial IFM of the SBLF group had the highest probability (79.26%) of falling within the ideal range (0.2–0.8 mm), and the SP and DP groups had probabilities of 27.10% and 3.14%, respectively. The axial stiffness in the SBLF group (1586 ± 130 N/mm) was significantly lower than that in the DP group (10,264 ± 2671 N/mm) (p < 0.001) but greater than that in the SP group (725 ± 178 N/mm) (p = 0.396). The range of axial loads to ultimate failure was 3385–4527 N (SBLF), 3377–4664 N (SP), and 3780–4804 N (DP). The shear motion of the fracture end was 0.35 ± 0.14 mm (SBLF), 0.16 ± 0.10 mm (SP), and 0.08 ± 0.04 mm (DP) (p < 0.001). The torsional stiffness was 1.68 ± 0.14 Nm/degree (SBLF), 2.32 ± 0.29 Nm/degree (SP) (SBLF&SP, p < 0.001), and 3.53 ± 0.73 Nm/degree (DP) (SBLF&DP, p < 0.001). Conclusions The SBLF structure may exhibit a better biomechanical performance compared with the SP and DP in providing the best quantity and more symmetrical interfragmentary movement for AO/OTA 32‐A3.2 fractures.
Collapse
Affiliation(s)
- Jianwei Hu
- Department of Orthopaedics, First Medical Center, Chinese PLA General Hospital, National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, Beijing, China.,Department of Orthopaedics, Tangshan Gongren Hospital, Tangshan, China
| | - Ye Peng
- Department of Orthopaedics, First Medical Center, Chinese PLA General Hospital, National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, Beijing, China
| | - Jiantao Li
- Department of Orthopaedics, First Medical Center, Chinese PLA General Hospital, National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, Beijing, China
| | - Ming Li
- Department of Orthopaedics, First Medical Center, Chinese PLA General Hospital, National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, Beijing, China
| | - Ying Xiong
- Department of Orthopaedics, Yan'an Hospital Affiliated to Kunming Medical University, Kunming, China
| | - Jiayu Xiao
- Department of Orthopaedics, Yan'an Hospital Affiliated to Kunming Medical University, Kunming, China
| | - Licheng Zhang
- Department of Orthopaedics, First Medical Center, Chinese PLA General Hospital, National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, Beijing, China
| | - Peifu Tang
- Department of Orthopaedics, First Medical Center, Chinese PLA General Hospital, National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, Beijing, China
| |
Collapse
|
6
|
Katakam A, Hosseinzadeh S, Humphrey TJ, Collins A, Shin D, Melnic CM, Bragdon C, Bedair HS. Different Designs of Proximal Femoral Stems for Total Hip Arthroplasty: Mid-Term Clinical and Patient-Reported Functional Outcomes. Cureus 2021; 13:e19745. [PMID: 34938623 PMCID: PMC8684824 DOI: 10.7759/cureus.19745] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/19/2021] [Indexed: 11/25/2022] Open
Abstract
INTRODUCTION A comprehensive comparison of the performance of different femoral stem geometries in total hip arthroplasty (THA) is yet to be described. The primary aim of this study was to evaluate objective and subjective outcome measures in primary THA with different femoral implant styles. METHODS Stems were classified into the following five classes: cemented, conical, fit and fill, modular, and wedge. The objective outcomes of interest were the length of inpatient hospital stay (LOS), 90-day readmission rate, one-year revision rate, and two-year mortality rate. Preoperative and postoperative patient-reported outcome measures (PROMs), including hip disability and osteoarthritis outcome score (HOOS) - physical function shortform (HOOS-PS), patient-reported outcomes measurement information system physical function short form 10a (PROMIS PF-10a), and patient-reported outcomes measurement information system - short form - mental 10a (PROMIS M-10a) were recorded and compared between different classes. RESULTS Patients with a wedge stem had a significantly lower LOS versus every other stem group, while patients with a cemented stem had the highest LOS, approximately twofold that of the wedge stem group. Accounting for potential confounders, the conical and fit and fill groups had a significantly higher two-year mortality rate than the wedge stem group. Fit and fill stems conferred a slight risk of revision THA at one-year compared to wedge stems. There was no significant difference in the rates of failure to achieve the minimal clinically important difference (MCID) for the PROMs. CONCLUSION Placement of wedge stems resulted in a significantly lower LOS compared to every other stem class and a lower mortality rate than the conical, fit and fill, and modular stems. As for the 90-day readmission, one-year revision, and the rates of failure to achieve the MCID for general or hip-specific PROMs, stem design had no meaningful effect.
Collapse
Affiliation(s)
- Akhil Katakam
- Orthopaedics, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| | - Shayan Hosseinzadeh
- Orthopaedics, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| | - Tyler J Humphrey
- Orthopaedics, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| | - Austin Collins
- Orthopaedics, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| | - David Shin
- Orthopaedics, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| | - Christopher M Melnic
- Orthopaedics, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| | - Charles Bragdon
- Orthopaedics, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| | - Hany S Bedair
- Orthopaedics, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| |
Collapse
|
7
|
Tatani I, Solou K, Panagopoulos A, Lakoumentas J, Kouzelis A, Megas P. Short-term clinical and radiological results of two different design metaphyseal fitting femoral stems in total hip arthroplasty: a prospective, randomized trial. J Orthop Surg Res 2021; 16:316. [PMID: 34001204 PMCID: PMC8127309 DOI: 10.1186/s13018-021-02465-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Accepted: 05/06/2021] [Indexed: 11/12/2022] Open
Abstract
Background There is great design variability on short femoral stems available on the market. This study aims to evaluate the short-term clinical and radiological results of two different design short femoral stems, both classified as shortened tapered stems. Methods From March 2016 to March 2018, a prospective, randomized, parallel-group design study was conducted to compare functional and radiological outcomes of 45 patients underwent THA using the Tri-Lock Bone Preservation Stem and 45 patients underwent THA with the Minima S stem at a minimum 2 years of follow-up. Patients were assessed clinically and radiographically prior to surgery as well as at 3, 6, 12, and 24 months postoperatively. Primary outcomes were the change in health-related quality of life assessed with Western Ontario and McMaster Universities Osteoarthritis Index and 36-Item Short Form Health Survey and also the incidence of all hip-related complications. Secondary aims included hip function evaluated with the Harris hip score, rates of patient satisfaction, and the outcomes of a detailed radiological analysis. Results There were no significant differences between the 2 study groups in terms of patient-reported outcomes measurements, satisfaction scores, and complication rates at any of the measurement times. In both groups, stable fixation and radiographic osseointegration were achieved. However, analysis of the calcar region showed that 57.8% and 28.9% of patients had grade 1 or 2 stress shielding, in Tri-Lock and Minima S implantation group, respectively (p=0.015). Regarding coronal alignment, stems were placed in slight varus, valgus, and neutral position in 51.1%, 13.3%, and 35.6% of patients, respectively, in Tri-Lock BPS group. The Minima S stem was implanted at slight varus and valgus in 60% and 40% of patients, respectively, and neither stem in the exact neutral position. Conclusions Both different design short femoral stems demonstrated excellent clinical performance at short-term follow up. Nevertheless, concerns were raised regarding the incidence of stress shielding phenomenon and mild discrepancies in coronal stem alignment during implantation. The clinical impact of these observations should be further evaluated through larger cohorts and longer follow-up. Trial registration ISRCTN registry, ISRCTN10096716. Registered on May 8, 2018—Retrospectively registered
Collapse
Affiliation(s)
- I Tatani
- Orthopaedic Department, University Hospital of Patras, Papanikolaou 1, Rio-Patra, 26504, Patras, Greece.
| | - K Solou
- Orthopaedic Department, University Hospital of Patras, Papanikolaou 1, Rio-Patra, 26504, Patras, Greece
| | - A Panagopoulos
- Orthopaedic Department, University Hospital of Patras, Papanikolaou 1, Rio-Patra, 26504, Patras, Greece
| | - J Lakoumentas
- Laboratory Department of Medical Physics, School of Medicine, University of Patras, Patras, Greece
| | - A Kouzelis
- Orthopaedic Department, University Hospital of Patras, Papanikolaou 1, Rio-Patra, 26504, Patras, Greece
| | - P Megas
- Orthopaedic Department, University Hospital of Patras, Papanikolaou 1, Rio-Patra, 26504, Patras, Greece
| |
Collapse
|
8
|
Rivera F, Bardelli A, Giolitti A. Promising medium-term results of anterior approach with an anatomical short stem in primary hip arthroplasty. J Orthop Traumatol 2021; 22:8. [PMID: 33675436 PMCID: PMC7936996 DOI: 10.1186/s10195-021-00567-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2020] [Accepted: 02/08/2021] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND In the last decade, the increase in the use of the direct anterior approach to the hip has contributed to the diffusion of the use of short stems in orthopedic surgery. The aim of the study is to verify the medium-term clinical and radiographic results of a cementless anatomic short stem in the anterior approach to the hip. We also want to verify whether the use of the standard operating room table or the leg positioner can affect the incidence of pre- and postoperative complications. MATERIALS AND METHODS All total hip arthroplasty patients with a 1-year minimum follow-up who were operated using the MiniMAX stem between January 2010 and December 2019 were included in this study. Clinical evaluation included the Harris Hip Score (HHS), Western Ontario and McMaster Universities Hip Outcome Assessment (WOMAC) Score, and Short Form-36 (SF-36) questionnaires. Bone resorption and remodeling, radiolucency, osteolysis, and cortical hypertrophy were analyzed in the postoperative radiograph and were related to the final follow-up radiographic results. Complications due to the use of the standard operating room table or the leg positioner were evaluated. RESULTS A total of 227 patients (238 hips) were included in the study. Average age at time of surgery was 62 years (range 38-77 years). Mean follow-up time was 67.7 months (range 12-120 months). Kaplan-Meier survivorship analysis after 10 years revealed 98.2% survival rate with revision for loosening as endpoint. The mean preoperative and postoperative HHS were 38.35 and 94.2, respectively. The mean preoperative and postoperative WOMAC Scores were 82.4 and 16.8, respectively. SF-36 physical and mental scores averaged 36.8 and 42.4, respectively, before surgery and 72.4 and 76.2, respectively, at final follow-up. The radiographic change around the stem showed bone hypertrophy in 55 cases (23%) at zone 3. In total, 183 surgeries were performed via the direct anterior approach (DAA) on a standard operating room table, and 44 surgeries were performed on the AMIS mobile leg positioner. Comparison between the two patient groups did not reveal significant differences. CONCLUSION In conclusion, a short, anatomic, cementless femoral stem provided stable metaphyseal fixation in younger patients. Our clinical and radiographic results support the use of this short stem in the direct anterior approach. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- Fabrizio Rivera
- Orthopedics and Trauma Department, SS Annunziata Hospital, ASL CN1, Savigliano (CN), Italy.
| | - Alessandro Bardelli
- Orthopedics and Trauma Department, SS Annunziata Hospital, ASL CN1, Savigliano (CN), Italy
| | - Andrea Giolitti
- Orthopeadics and Traumatology Department, Faculty of Medicine and Surgery, CTO Hospital, University of Turin, Turin, Italy
| |
Collapse
|
9
|
Marsh M, Newman S. Trends and developments in hip and knee arthroplasty technology. J Rehabil Assist Technol Eng 2021; 8:2055668320952043. [PMID: 33614108 PMCID: PMC7874345 DOI: 10.1177/2055668320952043] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2019] [Accepted: 08/03/2020] [Indexed: 01/04/2023] Open
Abstract
The developments in hip and knee arthroplasty over recent years have aimed to improve outcomes, reduce complications and improve implant survival. This review describes some of the most interesting trends and developments in this important and fast-moving field. Notable developments have included ceramic hip resurfacing, mini hip stems, cementless knee replacement and the wider adoption of the dual mobility articulation for hip arthroplasty. Advances in additive manufacturing and the surface modification of joint replacements offer increasing options for more challenging arthroplasty cases. Robotic assisted surgery is one of the most interesting developments in hip and knee surgery. The recent growth in the use of this technology is providing data that will help determine whether this approach should become the standard of care for hip and knee arthroplasty in the future.
Collapse
Affiliation(s)
- Martin Marsh
- Nuffield Orthopaedic Centre, Oxford University Hospitals NHS Trust, Oxford, UK
| | - Simon Newman
- Nuffield Orthopaedic Centre, Oxford University Hospitals NHS Trust, Oxford, UK
| |
Collapse
|
10
|
Tatani I, Megas P, Panagopoulos A, Diamantakos I, Nanopoulos P, Pantelakis S. Comparative analysis of the biomechanical behavior of two different design metaphyseal-fitting short stems using digital image correlation. Biomed Eng Online 2020; 19:65. [PMID: 32814586 PMCID: PMC7437017 DOI: 10.1186/s12938-020-00806-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Accepted: 08/04/2020] [Indexed: 01/26/2023] Open
Abstract
BACKGROUND The progressive evolution in hip replacement research is directed to follow the principles of bone and soft tissue sparing surgery. Regarding hip implants, a renewed interest has been raised towards short uncemented femoral implants. A heterogeneous group of short stems have been designed with the aim to approximate initial, post-implantation bone strain to the preoperative levels in order to minimize the effects of stress shielding. This study aims to investigate the biomechanical properties of two distinctly designed femoral implants, the TRI-LOCK Bone Preservation Stem, a shortened conventional stem and the Minima S Femoral Stem, an even shorter and anatomically shaped stem, based on experiments and numerical simulations. Furthermore, finite element models of implant-bone constructs should be evaluated for their validity against mechanical tests wherever it is possible. In this work, the validation was performed via a direct comparison of the FE calculated strain fields with their experimental equivalents obtained using the digital image correlation technique. RESULTS Design differences between Trilock BPS and Minima S femoral stems conditioned different strain pattern distributions. A distally shifting load distribution pattern as a result of implant insertion and also an obvious decrease of strain in the medial proximal aspect of the femur was noted for both stems. Strain changes induced after the implantation of the Trilock BPS stem at the lateral surface were greater compared to the non-implanted femur response, as opposed to those exhibited by the Minima S stem. Linear correlation analyses revealed a reasonable agreement between the numerical and experimental data in the majority of cases. CONCLUSION The study findings support the use of DIC technique as a preclinical evaluation tool of the biomechanical behavior induced by different implants and also identify its potential for experimental FE model validation. Furthermore, a proximal stress-shielding effect was noted after the implantation of both short-stem designs. Design-specific variations in short stems were sufficient to produce dissimilar biomechanical behaviors, although their clinical implication must be investigated through comparative clinical studies.
Collapse
Affiliation(s)
- I Tatani
- Orthopaedic Department, University Hospital of Patras, Papanikolaou 1, Rio-Patra, 26504, Patras, Greece.
| | - P Megas
- Orthopaedic Department, University Hospital of Patras, Papanikolaou 1, Rio-Patra, 26504, Patras, Greece
| | - A Panagopoulos
- Orthopaedic Department, University Hospital of Patras, Papanikolaou 1, Rio-Patra, 26504, Patras, Greece
| | - I Diamantakos
- Laboratory of Technology and Strength of Materials, Department of Mechanical Engineering and Aeronautics, University of Patras, Patras, Greece
| | - Ph Nanopoulos
- Department of Computer Engineering & Informatics, University of Patras, Patras, Greece
| | - Sp Pantelakis
- Laboratory of Technology and Strength of Materials, Department of Mechanical Engineering and Aeronautics, University of Patras, Patras, Greece
| |
Collapse
|
11
|
Bone remodelling and integration of two different types of short stem: a dual-energy X-ray - absorptiometry study. INTERNATIONAL ORTHOPAEDICS 2020; 44:839-846. [PMID: 32219497 DOI: 10.1007/s00264-020-04545-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2020] [Accepted: 03/18/2020] [Indexed: 10/24/2022]
Abstract
PURPOSE Different kinds of bone preserving hip stems have been created to assure a more physiological distribution of the strengths on the femur. The aim of this research is to evaluate the density reaction of the periprosthetic bone while changing the conformation of the prosthetic implant on dual-energy X-ray - absorptiometry (DXA). METHODS This is a prospective, single-centre study assessing bone remodelling changes after implantation of two short hip stems, dividing the patients in two groups according to the implant used: 20 in group A, Metha (B-Braun), and 16 in group B, SMF (Smith and Nephew). All participants had a pre-operative and a post-operative (24 months) DXA evaluating the changes in bone mass density (BMD) occurred in the five Gruen's zones. RESULTS Compared to the pre-operative value, differences in BMD percentage were statistically significant only in ROI 4 (p < 0.05), with an increase in both groups (9 and 18%, respectively). The average increase in BMD was of 7.3% and 7.2% in the 2 groups. CONCLUSION According to our study, both stems have proved able to provide good load distribution across the metaphyseal region favouring proper system integration. Nonetheless, is certainly needed to perform other studies with longer follow-up and bigger populations to give strength to these conclusions.
Collapse
|