1
|
Volling C, Mataseje L, Graña-Miraglia L, Hu X, Anceva-Sami S, Coleman BL, Downing M, Hota S, Jamal AJ, Johnstone J, Katz K, Leis JA, Li A, Mahesh V, Melano R, Muller M, Nayani S, Patel S, Paterson A, Pejkovska M, Ricciuto D, Sultana A, Vikulova T, Zhong Z, McGeer A, Guttman DS, Mulvey MR. Epidemiology of healthcare-associated Pseudomonas aeruginosa in intensive care units: are sink drains to blame? J Hosp Infect 2024; 148:77-86. [PMID: 38554807 DOI: 10.1016/j.jhin.2024.03.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Revised: 02/23/2024] [Accepted: 03/04/2024] [Indexed: 04/02/2024]
Abstract
BACKGROUND Pseudomonas aeruginosa (PA) is a common cause of healthcare-associated infection (PA-HAI) in the intensive care unit (ICU). AIM To describe the epidemiology of PA-HAI in ICUs in Ontario, Canada, and to identify episodes of sink-to-patient PA transmission. METHODS This was a prospective cohort study of patients in six ICUs from 2018 to 2019, with retrieval of PA clinical isolates, and PA-screening of antimicrobial-resistant organism surveillance rectal swabs, and of sink drain, air, and faucet samples. All PA isolates underwent whole-genome sequencing. PA-HAI was defined using US National Healthcare Safety Network criteria. ICU-acquired PA was defined as PA isolated from specimens obtained ≥48 h after ICU admission in those with prior negative rectal swabs. Sink-to-patient PA transmission was defined as ICU-acquired PA with close genomic relationship to isolate(s) previously recovered from sinks in a room/bedspace occupied 3-14 days prior to collection date of the relevant patient specimen. FINDINGS Over ten months, 72 PA-HAIs occurred among 60/4263 admissions. The rate of PA-HAI was 2.40 per 1000 patient-ICU-days; higher in patients who were PA-colonized on admission. PA-HAI was associated with longer stay (median: 26 vs 3 days uninfected; P < 0.001) and contributed to death in 22/60 cases (36.7%). Fifty-eight admissions with ICU-acquired PA were identified, contributing 35/72 (48.6%) PA-HAIs. Four patients with five PA-HAIs (6.9%) had closely related isolates previously recovered from their room/bedspace sinks. CONCLUSION Nearly half of PA causing HAI appeared to be acquired in ICUs, and 7% of PA-HAIs were associated with sink-to-patient transmission. Sinks may be an under-recognized reservoir for HAIs.
Collapse
Affiliation(s)
- C Volling
- Department of Microbiology, Sinai Health, Toronto, Canada.
| | - L Mataseje
- National Microbiology Laboratory, Public Health Agency of Canada, Winnipeg, Canada
| | - L Graña-Miraglia
- Department of Cell & Systems Biology, University of Toronto, Toronto, Canada
| | - X Hu
- Department of Cell & Systems Biology, University of Toronto, Toronto, Canada
| | - S Anceva-Sami
- Department of Microbiology, Sinai Health, Toronto, Canada
| | - B L Coleman
- Department of Microbiology, Sinai Health, Toronto, Canada
| | | | - S Hota
- Department of Medicine, University Health Network, Toronto, Canada
| | - A J Jamal
- Department of Microbiology, Sinai Health, Toronto, Canada
| | - J Johnstone
- Department of Microbiology, Sinai Health, Toronto, Canada
| | - K Katz
- Department of Medicine, North York General Hospital, Toronto, Canada
| | - J A Leis
- Department of Medicine, Sunnybrook Health Sciences Centre, Toronto, Canada
| | - A Li
- Department of Microbiology, Sinai Health, Toronto, Canada
| | - V Mahesh
- Department of Microbiology, Sinai Health, Toronto, Canada
| | - R Melano
- Pan American Health Organization, Washington, USA
| | - M Muller
- Department of Medicine, Unity Health Toronto, Toronto, Canada
| | - S Nayani
- Department of Microbiology, Sinai Health, Toronto, Canada
| | - S Patel
- Public Health Ontario Laboratory, Toronto, Canada
| | - A Paterson
- Department of Microbiology, Sinai Health, Toronto, Canada
| | - M Pejkovska
- Department of Microbiology, Sinai Health, Toronto, Canada
| | - D Ricciuto
- Department of Medicine, Lakeridge Health, Oshawa, Canada
| | - A Sultana
- Department of Microbiology, Sinai Health, Toronto, Canada
| | - T Vikulova
- Department of Microbiology, Sinai Health, Toronto, Canada
| | - Z Zhong
- Department of Microbiology, Sinai Health, Toronto, Canada
| | - A McGeer
- Department of Microbiology, Sinai Health, Toronto, Canada
| | - D S Guttman
- Department of Cell & Systems Biology, University of Toronto, Toronto, Canada; Centre for the Analysis of Genome Evolution and Function, Department of Cell and Systems Biology, University of Toronto, Toronto, Canada
| | - M R Mulvey
- National Microbiology Laboratory, Public Health Agency of Canada, Winnipeg, Canada
| |
Collapse
|
2
|
Kim UJ, Choi SM, Kim M, Kim S, Shin SU, Oh SR, Park JW, Shin HY, Kim YJ, Lee U, Choi OJ, Park HY, Shin JH, Kim SE, Kang SJ, Jung SI, Park KH. Hospital water environment and antibiotic use: Key factors in a nosocomial outbreak of carbapenemase-producing Serratia marcescens. J Hosp Infect 2024:S0195-6701(24)00167-1. [PMID: 38740300 DOI: 10.1016/j.jhin.2024.04.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 04/07/2024] [Accepted: 04/09/2024] [Indexed: 05/16/2024]
Abstract
BACKGROUND The healthcare water environment is a potential reservoir of carbapenem-resistant organisms (CROs). Here, we report the role of the water environment as a reservoir and the infection control measures applied to suppress a prolonged outbreak of Klebsiella pneumoniae carbapenemase-producing Serratia marcescens (KPC-SM) in two intensive care units (ICUs). METHODS The outbreak occurred in the ICUs of a tertiary hospital from October 2020 to July 2021. Comprehensive patient contact tracing and environmental assessments were conducted, and a case-control study was performed to identify factors associated with the acquisition of KPC-SM. Associations among isolates were assessed via pulsed-field gel electrophoresis (PFGE). Antibiotic usage was analyzed. . RESULTS The outbreak consisted of two waves involving a total of 30 patients with KPC-SM. Multiple environmental cultures identified KPC-SM in a sink, a dirty utility room, and a communal bathroom shared by the ICUs, together with the waste bucket of a continuous renal replacement therapy (CRRT) system. The genetic similarity of the KPC-SM isolates from patients and the environment was confirmed by PFGE. A retrospective review of 30 cases identified that the use of CRRT and antibiotics were associated with acquisition of KPC-SM (p < 0.05). There was a continuous increase in the use of carbapenems; notably, the use of colistin has increased since 2019. CONCLUSION Our study demonstrates that CRRT systems, along with other hospital water environments, are significant potential sources of resistant microorganisms, underscoring the necessity of enhancing infection control practices in these areas.
Collapse
Affiliation(s)
- Uh Jin Kim
- Department of Infectious Diseases, Chonnam National University Hospital, Gwangju, Republic of Korea; Department of Infectious Diseases, Chonnam National University Medical School, Gwangju, Republic of Korea
| | - Su-Mi Choi
- Department of Infectious Diseases, Chonnam National University Hospital, Gwangju, Republic of Korea
| | - Minji Kim
- Department of Infectious Diseases, Chonnam National University Hospital, Gwangju, Republic of Korea
| | - Sarah Kim
- Department of Infectious Diseases, Chonnam National University Hospital, Gwangju, Republic of Korea
| | - Sung Un Shin
- Department of Infectious Diseases, Chonnam National University Hospital, Gwangju, Republic of Korea
| | - Sa-Rang Oh
- Department of Infection Control Unit, Chonnam National University Hospital, Gwangju, Republic of Korea
| | - Ji-Won Park
- Department of Infection Control Unit, Chonnam National University Hospital, Gwangju, Republic of Korea
| | - Hwa Young Shin
- Department of Infection Control Unit, Chonnam National University Hospital, Gwangju, Republic of Korea
| | - You Jung Kim
- Department of Infection Control Unit, Chonnam National University Hospital, Gwangju, Republic of Korea
| | - Unhee Lee
- Department of Infection Control Unit, Chonnam National University Hospital, Gwangju, Republic of Korea
| | - Ok-Ja Choi
- Department of Infection Control Unit, Chonnam National University Hospital, Gwangju, Republic of Korea
| | - Hyun-Young Park
- Department of Pharmacy, Chonnam National University Hospital, Gwangju, Republic of Korea
| | - Jong-Hee Shin
- Department of Laboratory Medicine, Chonnam National University Hospital, Gwangju, Republic of Korea; Department of Infectious Diseases, Chonnam National University Medical School, Gwangju, Republic of Korea
| | - Seong Eun Kim
- Department of Infectious Diseases, Chonnam National University Hospital, Gwangju, Republic of Korea; Department of Infectious Diseases, Chonnam National University Medical School, Gwangju, Republic of Korea
| | - Seung-Ji Kang
- Department of Infectious Diseases, Chonnam National University Hospital, Gwangju, Republic of Korea; Department of Infectious Diseases, Chonnam National University Medical School, Gwangju, Republic of Korea
| | - Sook In Jung
- Department of Infectious Diseases, Chonnam National University Hospital, Gwangju, Republic of Korea; Department of Infectious Diseases, Chonnam National University Medical School, Gwangju, Republic of Korea
| | - Kyung-Hwa Park
- Department of Infectious Diseases, Chonnam National University Hospital, Gwangju, Republic of Korea; Department of Infection Control Unit, Chonnam National University Hospital, Gwangju, Republic of Korea; Department of Infectious Diseases, Chonnam National University Medical School, Gwangju, Republic of Korea.
| |
Collapse
|
3
|
Vega AD, DeRonde K, Jimenez A, Piazza M, Vu C, Martinez O, Rojas LJ, Marshall S, Yasmin M, Bonomo RA, Abbo LM. Difficult-to-treat (DTR) Pseudomonas aeruginosa harboring Verona-Integron metallo-β-lactamase ( blaVIM): infection management and molecular analysis. Antimicrob Agents Chemother 2024; 68:e0147423. [PMID: 38602418 PMCID: PMC11064525 DOI: 10.1128/aac.01474-23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Accepted: 03/11/2024] [Indexed: 04/12/2024] Open
Abstract
Pseudomonas aeruginosa harboring Verona Integron-encoded metallo-β-lactamase enzymes (VIM-CRPA) have been associated with infection outbreaks in several parts of the world. In the US, however, VIM-CRPA remain rare. Starting in December 2018, we identified a cluster of cases in our institution. Herein, we present our epidemiological investigation and strategies to control/manage these challenging infections. This study was conducted in a large academic healthcare system in Miami, FL, between December 2018 and January 2022. Patients were prospectively identified via rapid molecular diagnostics when cultures revealed carbapenem-resistant P. aeruginosa. Alerts were received in real time by the antimicrobial stewardship program and infection prevention teams. Upon alert recognition, a series of interventions were performed as a coordinated effort. A retrospective chart review was conducted to collect patient demographics, antimicrobial therapy, and clinical outcomes. Thirty-nine VIM-CRPA isolates led to infection in 21 patients. The majority were male (76.2%); the median age was 52 years. The majority were mechanically ventilated (n = 15/21; 71.4%); 47.6% (n = 10/21) received renal replacement therapy at the time of index culture. Respiratory (n = 20/39; 51.3%) or bloodstream (n = 13/39; 33.3%) were the most common sources. Most infections (n = 23/37; 62.2%) were treated with an aztreonam-avibactam regimen. Six patients (28.6%) expired within 30 days of index VIM-CRPA infection. Fourteen isolates were selected for whole genome sequencing. Most of them belonged to ST111 (12/14), and they all carried blaVIM-2 chromosomally. This report describes the clinical experience treating serious VIM-CRPA infections with either aztreonam-ceftazidime/avibactam or cefiderocol in combination with other agents. The importance of implementing infection prevention strategies to curb VIM-CRPA outbreaks is also demonstrated.
Collapse
Affiliation(s)
- Ana D. Vega
- Department of Pharmacy, Jackson Health System, Miami, Florida, USA
| | - Kailynn DeRonde
- Department of Pharmacy, Jackson Health System, Miami, Florida, USA
| | - Adriana Jimenez
- Department of Pharmacy, Jackson Health System, Miami, Florida, USA
- Department of Epidemiology, Florida International University, Miami, Florida, USA
| | - Michael Piazza
- Department of Medicine, Virtua Medical Group, Medford, New Jersey, USA
| | - Christine Vu
- Department of Pharmacy, Jackson Health System, Miami, Florida, USA
| | - Octavio Martinez
- Department of Pharmacy, Jackson Health System, Miami, Florida, USA
- Department of Medicine, University of Miami Miller School of Medicine, Miami, Florida, USA
| | - Laura J. Rojas
- Department of Molecular Biology and Microbiology, Case Western Reserve University School of Medicine, Cleveland, Ohio, USA
- CWRU-Cleveland VAMC Center for Antimicrobial Resistance and Epidemiology (Case VA CARES), Cleveland, Ohio, USA
| | - Steven Marshall
- Department of Medicine, Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, Ohio, USA
| | - Mohamad Yasmin
- Department of Medicine, Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, Ohio, USA
| | - Robert A. Bonomo
- Department of Molecular Biology and Microbiology, Case Western Reserve University School of Medicine, Cleveland, Ohio, USA
- CWRU-Cleveland VAMC Center for Antimicrobial Resistance and Epidemiology (Case VA CARES), Cleveland, Ohio, USA
- Department of Medicine, Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, Ohio, USA
- Departments of Proteomics, Case Western Reserve University School of Medicine, Cleveland, Ohio, USA
- Department of Pharmacology, Case Western Reserve University School of Medicine, Cleveland, Ohio, USA
- Department of Biochemistry, Case Western Reserve University School of Medicine, Cleveland, Ohio, USA
| | - Lilian M. Abbo
- Department of Pharmacy, Jackson Health System, Miami, Florida, USA
- Department of Medicine, University of Miami Miller School of Medicine, Miami, Florida, USA
| |
Collapse
|
4
|
Fucini GB, Geffers C, Schwab F, Behnke M, Sunder W, Moellmann J, Gastmeier P. Sinks in patient rooms in ICUs are associated with higher rates of hospital-acquired infection: a retrospective analysis of 552 ICUs. J Hosp Infect 2023; 139:99-105. [PMID: 37308060 DOI: 10.1016/j.jhin.2023.05.018] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 05/15/2023] [Accepted: 05/22/2023] [Indexed: 06/14/2023]
Abstract
BACKGROUND Sinks in hospitals are a possible reservoir for healthcare-related pathogens. They have been identified as a source of nosocomial outbreaks in intensive care units (ICU); however, their role in non-outbreak settings remains unclear. AIM To investigate whether sinks in ICU patient rooms are associated with a higher incidence of hospital-acquired infection (HAI). METHODS This analysis used surveillance data from the ICU component of the German nosocomial infection surveillance system (KISS) from 2017 to 2020. Between September and October 2021, all participating ICUs were surveyed about the presence of sinks in their patient rooms. The ICUs were then divided into two groups: the no-sink group (NSG) and the sink group (SG). Primary and secondary outcomes were total HAIs and HAIs associated with Pseudomonas aeruginosa (HAI-PA). FINDINGS In total, 552 ICUs (NSG N=80, SG N=472) provided data about sinks, total HAIs and HAI-PA. The incidence density per 1000 patient-days of total HAIs was higher in ICUs in the SG (3.97 vs 3.2). The incidence density of HAI-PA was also higher in the SG (0.43 vs 0.34). The risk of HAIs associated with all pathogens [incidence rate ratio (IRR)=1.24, 95% confidence interval (CI) 1.03-1.50] and the risk of lower respiratory tract infections associated with P. aeruginosa (IRR=1.44, 95% CI 1.10-1.90) were higher in ICUs with sinks in patient rooms. After adjusting for confounders, sinks were found to be an independent risk factor for HAI (adjusted IRR 1.21, 95% CI 1.01-1.45). CONCLUSIONS Sinks in patient rooms are associated with a higher number of HAIs per patient-day in the ICU. This should be considered when planning new ICUs or renovating existing ones.
Collapse
Affiliation(s)
- G-B Fucini
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Institute of Hygiene and Environmental Medicine, Berlin, Germany; National Reference Centre for Surveillance of Nosocomial Infections, Berlin, Germany.
| | - C Geffers
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Institute of Hygiene and Environmental Medicine, Berlin, Germany; National Reference Centre for Surveillance of Nosocomial Infections, Berlin, Germany
| | - F Schwab
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Institute of Hygiene and Environmental Medicine, Berlin, Germany; National Reference Centre for Surveillance of Nosocomial Infections, Berlin, Germany
| | - M Behnke
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Institute of Hygiene and Environmental Medicine, Berlin, Germany; National Reference Centre for Surveillance of Nosocomial Infections, Berlin, Germany
| | - W Sunder
- Institute of Construction Design, Industrial and Health Care Building, Technische Universität Carolo Wilhelmina zu Braunschweig, Braunschweig, Germany
| | - J Moellmann
- Institute of Construction Design, Industrial and Health Care Building, Technische Universität Carolo Wilhelmina zu Braunschweig, Braunschweig, Germany
| | - P Gastmeier
- Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Institute of Hygiene and Environmental Medicine, Berlin, Germany; National Reference Centre for Surveillance of Nosocomial Infections, Berlin, Germany
| |
Collapse
|
5
|
Schneider JS, Froböse NJ, Kuczius T, Schwierzeck V, Kampmeier S. Sink Drains in a Neonatal Intensive Care Unit: A Retrospective Risk Assessment and Evaluation. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:6692. [PMID: 37681832 PMCID: PMC10487867 DOI: 10.3390/ijerph20176692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 08/22/2023] [Accepted: 08/29/2023] [Indexed: 09/09/2023]
Abstract
Water systems in health care facilities can form reservoirs for Gram-negative bacteria. While planning a new neonatal intensive care unit (NICU), we performed a retrospective evaluation of potential risks from water-diverting systems on the existing NICU of our tertiary care University Hospital. During 2017 to 2023, we recorded nine nosocomial cluster events with bacterial pathogens in our NICU. Of these, three clusters of Gram-negative bacteria were potentially related to sink drains: A Klebsiella oxytoca, a Pseudomonas aeruginosa, and an Enterobacter hormaechei cluster were uncovered by clinical routine screening of patients and breastmilk samples. They were confirmed using whole-genome sequencing and a subsequent core genome multilocus sequence typing (cgMLST) algorithm. Our observations highlight that the implementation of sink drains in a NICU may have negative effects on patients' safety. Construction planning should concentrate on the avoidance of washbasins in patient rooms when redesigning sensitive areas such as NICUs.
Collapse
Affiliation(s)
- Julia S. Schneider
- Institute of Hygiene, University Hospital Münster, 48149 Münster, Germany; (J.S.S.); (T.K.); (V.S.)
| | - Neele J. Froböse
- Institute of Medical Microbiology, University Hospital Münster, 48149 Münster, Germany;
| | - Thorsten Kuczius
- Institute of Hygiene, University Hospital Münster, 48149 Münster, Germany; (J.S.S.); (T.K.); (V.S.)
| | - Vera Schwierzeck
- Institute of Hygiene, University Hospital Münster, 48149 Münster, Germany; (J.S.S.); (T.K.); (V.S.)
| | - Stefanie Kampmeier
- Institute of Hygiene, University Hospital Münster, 48149 Münster, Germany; (J.S.S.); (T.K.); (V.S.)
- Institute for Hygiene and Microbiology, University of Würzburg, 97080 Würzburg, Germany
| |
Collapse
|
6
|
Ture Z, Güner R, Alp E. Antimicrobial stewardship in the intensive care unit. JOURNAL OF INTENSIVE MEDICINE 2023; 3:244-253. [PMID: 37533805 PMCID: PMC10391567 DOI: 10.1016/j.jointm.2022.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Revised: 10/03/2022] [Accepted: 10/10/2022] [Indexed: 08/04/2023]
Abstract
High resistance rates to antimicrobials continue to be a global health threat. The incidence of multidrug-resistant (MDR) microorganisms in intensive care units (ICUs) is quite high compared to in the community and other units in the hospital because ICU patients are generally older, have higher numbers of co-morbidities and immune-suppressed; moreover, the typically high rates of invasive procedures performed in the ICU increase the risk of infection by MDR microorganisms. Antimicrobial stewardship (AMS) refers to the implementation of coordinated interventions to improve and track the appropriate use of antibiotics while offering the best possible antibiotic prescription (according to dose, duration, and route of administration). Broad-spectrum antibiotics are frequently preferred in ICUs because of greater infection severity and colonization and infection by MDR microorganisms. For this reason, a number of studies on AMS in ICUs have increased in recent years. Reducing the use of broad-spectrum antibiotics forms the basis of AMS. For this purpose, parameters such as establishing an AMS team, limiting the use of broad-spectrum antimicrobials, terminating treatments early, using early warning systems, pursuing infection control, and providing education and feedback are used. In this review, current AMS practices in ICUs are discussed.
Collapse
Affiliation(s)
- Zeynep Ture
- Department of Infectious Diseases and Clinical Microbiology, Faculty of Medicine, Erciyes University, Kayseri 38039,Turkey
| | - Rahmet Güner
- Department of Infectious Diseases and Clinical Microbiology, Yıldırım Beyazıt University, Ankara 06800, Turkey
| | - Emine Alp
- Department of Infectious Diseases and Clinical Microbiology, Yıldırım Beyazıt University, Ankara 06800, Turkey
| |
Collapse
|
7
|
Chan A, Thure K, Tobey K, Shugart A, Schmedes S, Burks JA, Hardin H, Moore C, Carpenter T, Brooks S, Gable P, Moulton Meissner H, McAllister G, Lawsin A, Laufer Halpin A, Spalding Walters M, Keaton A. Containment of a Verona Integron-Encoded Metallo-Beta-Lactamase-Producing Pseudomonas aeruginosa Outbreak Associated With an Acute Care Hospital Sink-Tennessee, 2018-2020. Open Forum Infect Dis 2023; 10:ofad194. [PMID: 37180588 PMCID: PMC10173543 DOI: 10.1093/ofid/ofad194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Accepted: 04/06/2023] [Indexed: 05/16/2023] Open
Abstract
Background Contaminated healthcare facility wastewater plumbing is recognized as a source of carbapenemase-producing organism transmission. In August 2019, the Tennessee Department of Health (TDH) identified a patient colonized with Verona integron-encoded metallo-beta-lactamase-producing carbapenem-resistant Pseudomonas aeruginosa (VIM-CRPA). A record review revealed that 33% (4 of 12) of all reported patients in Tennessee with VIM had history of prior admission to acute care hospital (ACH) A intensive care unit (ICU) Room X, prompting further investigation. Methods A case was defined as polymerase chain reaction detection of blaVIM in a patient with prior admission to ACH A from November 2017 to November 2020. The TDH performed point prevalence surveys, discharge screening, onsite observations, and environmental testing at ACH A. The VIM-CRPA isolates underwent whole-genome sequencing (WGS). Results In a screening of 44% (n = 11) of 25 patients admitted to Room X between January and June 2020, we identified 36% (n = 4) colonized with VIM-CRPA, resulting in 8 cases associated with Room X from March 2018 to June 2020. No additional cases were identified in 2 point-prevalence surveys of the ACH A ICU. Samples from the bathroom and handwashing sink drains in Room X grew VIM-CRPA; all available case and environmental isolates were found to be ST253 harboring blaVIM-1 and to be closely related by WGS. Transmission ended after implementation of intensive water management and infection control interventions. Conclusions A single ICU room's contaminated drains were associated with 8 VIM-CRPA cases over a 2-year period. This outbreak highlights the need to include wastewater plumbing in hospital water management plans to mitigate the risk of transmission of antibiotic-resistant organisms to patients.
Collapse
Affiliation(s)
- Allison Chan
- Correspondence: Allison Chan, MPH, Healthcare Associated Infections and Antimicrobial Resistance Program, Communicable and Environmental Diseases and Emergency Preparedness, Tennessee Department of Health, 2525 West End Avenue, Suite 600, Nashville, TN 37203 (); Present Affiliation: Division of Epidemiology, Department of Medicine, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Katie Thure
- Present Affiliation: David Geffen School of Medicine, University of California, Los Angeles, California, USA
| | - Kelley Tobey
- Healthcare Associated Infections and Antimicrobial Resistance Program, Communicable and Environmental Diseases and Emergency Preparedness, Tennessee Department of Health, Nashville, Tennessee, USA
| | - Alicia Shugart
- Division of Healthcare Quality Promotion, Centers for Disease Control and Prevention, US Department of Health and Human Services, Atlanta, Georgia, USA
| | - Sarah Schmedes
- Florida Department of Health, Bureau of Public Health Laboratories, Jacksonville, Florida, USA
| | - James Albert Burks
- Division of Laboratory Services, Tennessee Department of Health, Nashville, Tennessee, USA
| | - Henrietta Hardin
- Division of Laboratory Services, Tennessee Department of Health, Nashville, Tennessee, USA
| | - Christina Moore
- Division of Laboratory Services, Tennessee Department of Health, Nashville, Tennessee, USA
| | - Tina Carpenter
- North Knoxville Medical Center, Knoxville, Tennessee, USA
| | | | - Paige Gable
- Division of Healthcare Quality Promotion, Centers for Disease Control and Prevention, US Department of Health and Human Services, Atlanta, Georgia, USA
| | - Heather Moulton Meissner
- Division of Healthcare Quality Promotion, Centers for Disease Control and Prevention, US Department of Health and Human Services, Atlanta, Georgia, USA
| | - Gillian McAllister
- Division of Healthcare Quality Promotion, Centers for Disease Control and Prevention, US Department of Health and Human Services, Atlanta, Georgia, USA
| | - Adrian Lawsin
- Division of Healthcare Quality Promotion, Centers for Disease Control and Prevention, US Department of Health and Human Services, Atlanta, Georgia, USA
| | - Alison Laufer Halpin
- Division of Healthcare Quality Promotion, Centers for Disease Control and Prevention, US Department of Health and Human Services, Atlanta, Georgia, USA
| | - Maroya Spalding Walters
- Division of Healthcare Quality Promotion, Centers for Disease Control and Prevention, US Department of Health and Human Services, Atlanta, Georgia, USA
| | - Amelia Keaton
- Present Affiliation: Division of Healthcare Quality Promotion, Centers for Disease Control and Prevention, US Department of Health and Human Services, Atlanta, Georgia, USA
| |
Collapse
|
8
|
Gideskog M, Falkeborn T, Welander J, Melhus Å. Source Control of Gram-Negative Bacteria Using Self-Disinfecting Sinks in a Swedish Burn Centre. Microorganisms 2023; 11:microorganisms11040965. [PMID: 37110388 PMCID: PMC10143680 DOI: 10.3390/microorganisms11040965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 03/31/2023] [Accepted: 04/05/2023] [Indexed: 04/29/2023] Open
Abstract
Several retrospective studies have identified hospital sinks as reservoirs of Gram-negative bacteria. The aim of this study was to prospectively investigate the bacterial transmission from sinks to patients and if self-disinfecting sinks could reduce this risk. Samples were collected weekly from sinks (self-disinfecting, treated with boiling water, not treated) and patients in the Burn Centre at Linköping University Hospital, Sweden. The antibiotic susceptibility of Gram-negative isolates was tested, and eight randomly chosen patient isolates and their connected sink isolates were subjected to whole genome sequencing (WGS). Of 489 sink samples, 232 (47%) showed growth. The most frequent findings were Stenotrophomonas maltophilia (n = 130), Pseudomonas aeruginosa (n = 128), and Acinetobacter spp. (n = 55). Bacterial growth was observed in 20% of the samplings from the self-disinfecting sinks and in 57% from the sinks treated with boiling water (p = 0.0029). WGS recognized one transmission of Escherichia coli sampled from an untreated sink to a patient admitted to the same room. In conclusion, the results showed that sinks can serve as reservoirs of Gram-negative bacteria and that self-disinfecting sinks can reduce the transmission risk. Installing self-disinfecting sinks in intensive care units is an important measure in preventing nosocomial infection among critically ill patients.
Collapse
Affiliation(s)
- Maria Gideskog
- Department of Communicable Disease and Infection Control, Linköping University Hospital, SE-581 85 Linköping, Sweden
- Department of Biomedical and Clinical Sciences, Linköping University, SE-581 85 Linköping, Sweden
| | - Tina Falkeborn
- Department of Biomedical and Clinical Sciences, Linköping University, SE-581 85 Linköping, Sweden
- Department of Clinical Microbiology, Linköping University Hospital, SE-581 85 Linköping, Sweden
| | - Jenny Welander
- Department of Biomedical and Clinical Sciences, Linköping University, SE-581 85 Linköping, Sweden
- Department of Clinical Microbiology, Linköping University Hospital, SE-581 85 Linköping, Sweden
| | - Åsa Melhus
- Section of Clinical Microbiology, Department of Medical Sciences, Uppsala University, SE-751 85 Uppsala, Sweden
| |
Collapse
|
9
|
Challenges in the Hospital Water System and Innovations to Prevent Healthcare-Associated Infections. CURRENT TREATMENT OPTIONS IN INFECTIOUS DISEASES 2023. [DOI: 10.1007/s40506-023-00261-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/19/2023]
|
10
|
Ofstead CL, Hopkins KM, Daniels FE, Smart AG, Wetzler HP. Splash generation and droplet dispersal in a well-designed, centralized high-level disinfection unit. Am J Infect Control 2022; 50:1200-1207. [PMID: 36244924 DOI: 10.1016/j.ajic.2022.08.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Revised: 08/03/2022] [Accepted: 08/04/2022] [Indexed: 11/01/2022]
Abstract
BACKGROUND Sterile processing personnel routinely decontaminate medical devices that are heavily soiled with blood, tissue, and secretions. Contamination may spread throughout processing areas, potentially exposing personnel and patient-ready devices, especially when there is insufficient separation between the dirty and clean areas. OBJECTIVE This study aimed to identify activities that generate splash, determine how far droplets travel during manual cleaning, characterize the impact of practices on splash generation, and assess effectiveness of personal protective equipment (PPE) at preventing splash exposure to technicians and visitors in the decontamination unit. METHODS Moisture-detection paper was affixed to PPE and environmental surfaces in a new processing department designed to optimize workflow and prevent cross-contamination. Droplet generation and dispersal were assessed during manual cleaning of a colonoscope and a transvaginal ultrasound probe. RESULTS Splash was generated by most activities and droplets were detected up to 7.25 feet away. Transporting wet endoscopes dispersed droplets on a 15-foot path from the sink to the automated endoscope reprocessor. Extensive droplets were detected on PPE worn by technicians at the sink and observers 3-4 feet away. CONCLUSIONS Manual cleaning of devices generated substantial splash, drenching technicians and the environment with droplets that traveled more than 7 feet. Engineering controls and better PPE are needed to reduce personnel exposure and risks associated with the potential dispersal of contaminated fluids throughout the facility.
Collapse
Affiliation(s)
| | | | - Frank E Daniels
- Department of High Level Disinfection & Sterilization, Virginia Commonwealth University Health, Richmond, VA
| | | | | |
Collapse
|
11
|
Prestel C, Moulton-Meissner H, Gable P, Stanton RA, Glowicz J, Franco L, McConnell M, Torres T, John D, Blackwell G, Yates R, Brown C, Reyes K, McAllister GA, Kunz J, Conners EE, Benedict KM, Kirby A, Mattioli M, Xu K, Gualandi N, Booth S, Novosad S, Arduino M, Halpin AL, Wells K, Walters MS. Dialysis Water Supply Faucet as Reservoir for Carbapenemase-Producing Pseudomonas aeruginosa. Emerg Infect Dis 2022; 28:2069-2073. [PMID: 36148936 PMCID: PMC9514332 DOI: 10.3201/eid2810.220731] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
During June 2017-November 2019, a total 36 patients with carbapenem-resistant Pseudomonas aeruginosa harboring Verona-integron-encoded metallo-β-lactamase were identified in a city in western Texas, USA. A faucet contaminated with the organism, identified through environmental sampling, in a specialty care room was the likely source for infection in a subset of patients.
Collapse
|
12
|
Godijk NG, Bootsma MCJ, Bonten MJM. Transmission routes of antibiotic resistant bacteria: a systematic review. BMC Infect Dis 2022; 22:482. [PMID: 35596134 PMCID: PMC9123679 DOI: 10.1186/s12879-022-07360-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Accepted: 03/28/2022] [Indexed: 11/16/2022] Open
Abstract
Background Quantification of acquisition routes of antibiotic resistant bacteria (ARB) is pivotal for understanding transmission dynamics and designing cost-effective interventions. Different methods have been used to quantify the importance of transmission routes, such as relative risks, odds ratios (OR), genomic comparisons and basic reproduction numbers. We systematically reviewed reported estimates on acquisition routes’ contributions of ARB in humans, animals, water and the environment and assessed the methods used to quantify the importance of transmission routes. Methods PubMed and EMBASE were searched, resulting in 6054 articles published up until January 1st, 2019. Full text screening was performed on 525 articles and 277 are included. Results We extracted 718 estimates with S. aureus (n = 273), E. coli (n = 157) and Enterobacteriaceae (n = 99) being studied most frequently. Most estimates were derived from statistical methods (n = 560), mainly expressed as risks (n = 246) and ORs (n = 239), followed by genetic comparisons (n = 85), modelling (n = 62) and dosage of ARB ingested (n = 17). Transmission routes analysed most frequently were occupational exposure (n = 157), travelling (n = 110) and contacts with carriers (n = 83). Studies were mostly performed in the United States (n = 142), the Netherlands (n = 87) and Germany (n = 60). Comparison of methods was not possible as studies using different methods to estimate the same route were lacking. Due to study heterogeneity not all estimates by the same method could be pooled. Conclusion Despite an abundance of published data the relative importance of transmission routes of ARB has not been accurately quantified. Links between exposure and acquisition are often present, but the frequency of exposure is missing, which disables estimation of transmission routes’ importance. To create effective policies reducing ARB, estimates of transmission should be weighed by the frequency of exposure occurrence. Supplementary Information The online version contains supplementary material available at 10.1186/s12879-022-07360-z.
Collapse
Affiliation(s)
- Noortje G Godijk
- Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.
| | - Martin C J Bootsma
- Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.,Department of Mathematics, Faculty of Sciences, Utrecht University, Utrecht, The Netherlands
| | - Marc J M Bonten
- Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| |
Collapse
|
13
|
Lynch JP, Zhanel GG. Pseudomonas aeruginosa Pneumonia: Evolution of Antimicrobial Resistance and Implications for Therapy. Semin Respir Crit Care Med 2022; 43:191-218. [PMID: 35062038 DOI: 10.1055/s-0041-1740109] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
Pseudomonas aeruginosa (PA), a non-lactose-fermenting gram-negative bacillus, is a common cause of nosocomial infections in critically ill or debilitated patients, particularly ventilator-associated pneumonia (VAP), and infections of urinary tract, intra-abdominal, wounds, skin/soft tissue, and bloodstream. PA rarely affects healthy individuals, but may cause serious infections in patients with chronic structural lung disease, comorbidities, advanced age, impaired immune defenses, or with medical devices (e.g., urinary or intravascular catheters, foreign bodies). Treatment of pseudomonal infections is difficult, as PA is intrinsically resistant to multiple antimicrobials, and may acquire new resistance determinants even while on antimicrobial therapy. Mortality associated with pseudomonal VAP or bacteremias is high (> 35%) and optimal therapy is controversial. Over the past three decades, antimicrobial resistance (AMR) among PA has escalated globally, via dissemination of several international multidrug resistant "epidemic" clones. We discuss the importance of PA as a cause of pneumonia including health care-associated pneumonia, hospital-acquired pneumonia, VAP, the emergence of AMR to this pathogen, and approaches to therapy (both empirical and definitive).
Collapse
Affiliation(s)
- Joseph P Lynch
- Division of Pulmonary, Critical Care Medicine, Allergy, and Clinical Immunology, Department of Medicine, The David Geffen School of Medicine at UCLA, Los Angeles, California
| | - George G Zhanel
- Department of Medical Microbiology/Infectious Diseases, University of Manitoba, Max Rady College of Medicine, Winnipeg, Manitoba, Canada
| |
Collapse
|
14
|
Probst K, Boutin S, Späth I, Scherrer M, Henny N, Sahin D, Heininger A, Heeg K, Nurjadi D. Direct-PCR from rectal swabs and environmental reservoirs: A fast and efficient alternative to detect bla OXA-48 carbapenemase genes in an Enterobacter cloacae outbreak setting. ENVIRONMENTAL RESEARCH 2022; 203:111808. [PMID: 34343553 DOI: 10.1016/j.envres.2021.111808] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Revised: 07/28/2021] [Accepted: 07/28/2021] [Indexed: 06/13/2023]
Abstract
Carbapenemase-producing bacteria are a risk factor in clinical settings worldwide. The aim of the study was to accelerate the time to results during an outbreak situation with blaOXA-48-positive Enterobacter cloacae by using a real-time multiplex quantitative PCR (qPCR) directly on rectal swab specimens and on wastewater samples to detect carbapenemase-producing bacteria. Thus, we analyzed 681 rectal swabs and 947 environmental samples during a five-month period by qPCR and compared the results to culture screening. The qPCR showed a sensitivity of 100% by testing directly from rectal swabs and was in ten cases more sensitive than the culture-based methods. Environmental screening for blaOXA-48-carbapenemase genes by qPCR revealed reservoirs of different carbapenemase genes that are potential sources of transmission and might lead to new outbreaks. The rapid identification of patients colonized with those isolates and screening of the hospital environment is essential for earlier patient treatment and eliminating potential sources of nosocomial infections.
Collapse
Affiliation(s)
- Katja Probst
- Department of Infectious Diseases, Medical Microbiology and Hospital Hygiene, University Hospital Heidelberg, Heidelberg, Germany.
| | - Sébastien Boutin
- Department of Infectious Diseases, Medical Microbiology and Hospital Hygiene, University Hospital Heidelberg, Heidelberg, Germany; Translational Lung Research Center Heidelberg (TLRC), German Center for Lung Research (DZL), Heidelberg University Hospital, Heidelberg, Germany
| | - Isabel Späth
- Department of Infectious Diseases, Medical Microbiology and Hospital Hygiene, University Hospital Heidelberg, Heidelberg, Germany
| | - Martin Scherrer
- Department of Infectious Diseases, Medical Microbiology and Hospital Hygiene, University Hospital Heidelberg, Heidelberg, Germany
| | - Nicole Henny
- Department of Infectious Diseases, Medical Microbiology and Hospital Hygiene, University Hospital Heidelberg, Heidelberg, Germany
| | - Delal Sahin
- Department of Infectious Diseases, Medical Microbiology and Hospital Hygiene, University Hospital Heidelberg, Heidelberg, Germany
| | - Alexandra Heininger
- Department of Infectious Diseases, Medical Microbiology and Hospital Hygiene, University Hospital Heidelberg, Heidelberg, Germany; Stabsstelle Krankenhaushygiene, Universitätsmedizin Mannheim, Mannheim, Germany
| | - Klaus Heeg
- Department of Infectious Diseases, Medical Microbiology and Hospital Hygiene, University Hospital Heidelberg, Heidelberg, Germany
| | - Dennis Nurjadi
- Department of Infectious Diseases, Medical Microbiology and Hospital Hygiene, University Hospital Heidelberg, Heidelberg, Germany
| |
Collapse
|
15
|
Redfern J, Wallace J, van Belkum A, Jaillard M, Whittard E, Ragupathy R, Verran J, Kelly P, Enright MC. Biofilm associated genotypes of multiple antibiotic resistant Pseudomonas aeruginosa. BMC Genomics 2021; 22:572. [PMID: 34311706 PMCID: PMC8314537 DOI: 10.1186/s12864-021-07818-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Accepted: 06/14/2021] [Indexed: 12/22/2022] Open
Abstract
BACKGROUND Pseudomonas aeruginosa is a ubiquitous environmental microorganism and also a common cause of infection. Its ability to survive in many different environments and persistently colonize humans is linked to its presence in biofilms formed on indwelling device surfaces. Biofilm promotes adhesion to, and survival on surfaces, protects from desiccation and the actions of antibiotics and disinfectants. RESULTS We examined the genetic basis for biofilm production on polystyrene at room (22 °C) and body temperature (37 °C) within 280 P. aeruginosa. 193 isolates (69 %) produced more biofilm at 22 °C than at 37 °C. Using GWAS and pan-GWAS, we found a number of accessory genes significantly associated with greater biofilm production at 22 °C. Many of these are present on a 165 kb region containing genes for heavy metal resistance (arsenic, copper, mercury and cadmium), transcriptional regulators and methytransferases. We also discovered multiple core genome SNPs in the A-type flagellin gene and Type II secretion system gene xpsD. Analysis of biofilm production of isolates of the MDR ST111 and ST235 lineages on stainless-steel revealed several accessory genes associated with enhanced biofilm production. These include a putative translocase with homology to a Helicobacter pylori type IV secretion system protein, a TA system II toxin gene and the alginate biosynthesis gene algA, several transcriptional regulators and methytransferases as well as core SNPs in genes involved in quorum sensing and protein translocation. CONCLUSIONS Using genetic association approaches we discovered a number of accessory genes and core-genome SNPs that were associated with enhanced early biofilm formation at 22 °C compared to 37 °C. These included a 165 kb genomic island containing multiple heavy metal resistance genes, transcriptional regulators and methyltransferases. We hypothesize that this genomic island may be associated with overall genotypes that are environmentally adapted to survive at lower temperatures. Further work to examine their importance in, for example gene-knockout studies, are required to confirm their relevance. GWAS and pan-GWAS approaches have great potential as a first step in examining the genetic basis of novel bacterial phenotypes.
Collapse
Affiliation(s)
- James Redfern
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester, United Kingdom
| | - Janine Wallace
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester, United Kingdom
| | | | | | - Elliot Whittard
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester, United Kingdom
| | - Roobinidevi Ragupathy
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester, United Kingdom
| | - Joanna Verran
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester, United Kingdom
| | - Peter Kelly
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester, United Kingdom
| | - Mark Charles Enright
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester, United Kingdom.
| |
Collapse
|
16
|
Chezganova EA, Efimova OS, Sakharova VM, Efimova AR, Sozinov SA, Ismagilov ZR, Brusina EB. A novel source of hospital microorganisms in healthcare settings. JOURNAL OF MICROBIOLOGY, EPIDEMIOLOGY AND IMMUNOBIOLOGY 2021. [DOI: 10.36233/0372-9311-120] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Background. Most healthcare-associated infections (HAI) develop due to a colonization of patients and healthcare workers by hospital strains of pathogens. The aim to study was to assess whether the dust within the health facilities can harbor microorganisms acting as a reservoir of HAIs.Materials and methods. Dust samples collected in the air ducts and ventilation grilles of health facilities underwent a detailed physicochemical analysis by means of scanning electron microscopy, dynamic light scattering, energy-dispersive X-ray spectroscopy, and high-temperature catalytic oxidation. Bacterial and viral diversity was investigated using an automated biochemical analyzer and polymerase chain reaction, respectively. Investigation of the microenvironment included detection of biofilms using a catalase indicator and quantification of viable microorganisms per 1 m3 air.Results. Dust from the hospital ventilation grilles and air ducts was contaminated with microorganisms in 71.13% of cases. Strikingly, multidrug-resistant and biofilm-forming strains have been found in 69.4% and 48.0% of samples, respectively. The total viable count before and after opening doors and windows was 276 and 462 colony-forming units/m3 respectively (p = 0.046). Biodiversity was represented by 21 genera of microorganisms which were consistently detected upon 6 months of follow-up. All samples contained a nanosized particulate matter. Chemical elements comprising dust were carbon (16.26–50.69%), oxygen (20.02–37.50%), nitrogen (1.59–25.03%), hydrogen (2.03–6.67%), sulfur (0.15–2.38%), calcium (0.19–7.49%), silicon (0.21–4.64%), chlorine (0.05–2.83%), sodium (0.07–1.86%), aluminum (0.36–1.78%), iron (0.08–1.61%), magnesium (0.11–1.40%), potassium (0.04–0.85%), and phosphorus (0.04–0.81%).Discussion. A wide range of multidrug-resistant strains of bacteria, detected in a hospital particulate matter with a diverse chemical composition, indicates the persistence of HAI-causing pathogens in the hospital environment.Conclusion. Dust from the ventilation grilles and adjacent air ducts should be considered as an additional reservoir of multidrug-resistant strains of bacteria in the healthcare settings.
Collapse
Affiliation(s)
| | - O. S. Efimova
- Institute of Coal Chemistry and Material Science of the Siberian Branch of the Russian Academy of Sciences
| | - V. M. Sakharova
- Research Institute for Complex Issues of Cardiovascular Diseases
| | - A. R. Efimova
- Kemerovo Regional Center for Hygiene and Epidemiology
| | - S. A. Sozinov
- Institute of Coal Chemistry and Material Science of the Siberian Branch of the Russian Academy of Sciences
| | - Z. R. Ismagilov
- Institute of Coal Chemistry and Material Science of the Siberian Branch of the Russian Academy of Sciences
| | | |
Collapse
|
17
|
Aranega-Bou P, Cornbill C, Verlander NQ, Moore G. A splash-reducing clinical handwash basin reduces droplet-mediated dispersal from a sink contaminated with Gram-negative bacteria in a laboratory model system. J Hosp Infect 2021; 114:171-174. [PMID: 33895165 DOI: 10.1016/j.jhin.2021.04.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Revised: 04/13/2021] [Accepted: 04/15/2021] [Indexed: 10/21/2022]
Abstract
Infection prevention strategies need to be identified and evaluated to reduce the risk associated with contaminated hospital sinks. This study used settle plates to compare the dispersal of Gram-negative bacteria from a conventional, rear-draining clinical handwash basin (CHWB) and a 'splash-reducing' CHWB with and/or without impaired drainage. Two scenarios were assessed: dispersal from a contaminated basin and dispersal from a contaminated drain. The associated tap was operated for 1 min and, for all contamination scenarios, the 'splash-reducing' CHWB had significantly lower odds of spreading contamination than the conventional CHWB.
Collapse
Affiliation(s)
- P Aranega-Bou
- Biosafety, Air and Water Microbiology Group, National Infection Service, Public Health England, Salisbury, UK.
| | - C Cornbill
- Biosafety, Air and Water Microbiology Group, National Infection Service, Public Health England, Salisbury, UK
| | - N Q Verlander
- Statistics Unit, Statistics, Modelling and Economics Department, National Infection Service, Public Health England, Colindale, UK
| | - G Moore
- Biosafety, Air and Water Microbiology Group, National Infection Service, Public Health England, Salisbury, UK
| |
Collapse
|
18
|
Sebre S, Abegaz WE, Seman A, Awoke T, Desalegn Z, Mihret W, Mihret A, Abebe T. Bacterial Profiles and Antimicrobial Susceptibility Pattern of Isolates from Inanimate Hospital Environments at Tikur Anbessa Specialized Teaching Hospital, Addis Ababa, Ethiopia. Infect Drug Resist 2020; 13:4439-4448. [PMID: 33364791 PMCID: PMC7751703 DOI: 10.2147/idr.s286293] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2020] [Accepted: 11/30/2020] [Indexed: 12/18/2022] Open
Abstract
Introduction Microbial contamination of the hospital environment plays an important role in the spread of healthcare-associated infections (HCAIs). This study was conducted to determine bacterial contamination, bacterial profiles, and antimicrobial susceptibility pattern of bacterial isolates from environmental surfaces and medical equipment. Methods A cross-sectional study was conducted at Tikur Anbessa Specialized Hospital (TASH) from June to September 2018. A total of 164 inanimate surfaces located at intensive care units (ICUs) and operation theaters (OTs) were swabbed. All isolates were identified by using routine bacterial culture, Gram staining, and a panel of biochemical tests. For each identified bacteria, antibiogram profiles were determined by the Kirby–Bauer disk diffusion method according to the guidelines of the Clinical and Laboratory Standards Institute (CLSI). Results Out of the 164 swabbed samples, 141 (86%) were positive for bacterial growth. The predominant bacteria identified from OTs and ICUs were Staphylococci aureus (23% vs 11.5%), Acinetobacter baumannii (3.8% vs 17.5%) and coagulase-negative Staphylococcus (CoNS) (12.6% vs 2.7%) respectively. Linens were the most contaminated materials among items studied at the hospital (14.8%). Gram-positive bacteria (GPB) had significantly high resistance levels to penicillin (92.8%), cefoxitin (83.5%), and erythromycin (53.6%). On the other hand, Gram-negative bacteria (GNB) revealed the highest resistance levels to ampicillin (97.5%), ceftazidime (91.3%), ceftriaxone (91.3%), and aztreonam (90%). However, a low resistance level was recorded for amikacin (25%) followed by Ciprofloxacin (37.5%). Of the 63 S. aureus isolates, 54 (85.7%) were methicillin-resistant S. aureus (MRSA). Conclusion The inanimate surfaces and commonly touched medical equipment within OTs and ICUs are reservoirs of potentially pathogenic bacteria that could predispose critically ill patients to acquire HCAIs. The proportions of the antimicrobial resistance profile of the isolates are much higher from studied clean inanimate environments.
Collapse
Affiliation(s)
- Shemse Sebre
- Department of Microbiology, Immunology, and Parasitology, School of Medicine, College of Health Sciences, Addis Ababa University, Addis Ababa, Ethiopia.,Armauer Hansen Research Institute, Addis Ababa, Ethiopia
| | - Woldaregay Erku Abegaz
- Department of Microbiology, Immunology, and Parasitology, School of Medicine, College of Health Sciences, Addis Ababa University, Addis Ababa, Ethiopia
| | - Aminu Seman
- Department of Microbiology, Immunology, and Parasitology, School of Medicine, College of Health Sciences, Addis Ababa University, Addis Ababa, Ethiopia.,Armauer Hansen Research Institute, Addis Ababa, Ethiopia
| | - Tewachew Awoke
- Department of Medical Laboratory Sciences, College of Medicine and Health Sciences, Bahir Dar University, Bahir Dar, Ethiopia
| | - Zelalem Desalegn
- Department of Microbiology, Immunology, and Parasitology, School of Medicine, College of Health Sciences, Addis Ababa University, Addis Ababa, Ethiopia
| | - Wude Mihret
- Armauer Hansen Research Institute, Addis Ababa, Ethiopia
| | - Adane Mihret
- Department of Microbiology, Immunology, and Parasitology, School of Medicine, College of Health Sciences, Addis Ababa University, Addis Ababa, Ethiopia.,Armauer Hansen Research Institute, Addis Ababa, Ethiopia
| | - Tamrat Abebe
- Department of Microbiology, Immunology, and Parasitology, School of Medicine, College of Health Sciences, Addis Ababa University, Addis Ababa, Ethiopia
| |
Collapse
|
19
|
Characterization of Putative Virulence Factors of Pseudomonas aeruginosa Strain RBS Isolated from a Saltern, Tunisia: Effect of Metal Ion Cofactors on the Structure and the Activity of LasB. BIOMED RESEARCH INTERNATIONAL 2020; 2020:6047528. [PMID: 32775429 PMCID: PMC7396000 DOI: 10.1155/2020/6047528] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Revised: 06/04/2020] [Accepted: 06/27/2020] [Indexed: 11/17/2022]
Abstract
Pseudomonas aeruginosa is a ubiquitous Gram-negative bacterium able to survive in diverse environments such as soil, plants, freshwater, and seawater. P. aeruginosa can be an opportunistic pathogen to humans when their immune system is deficient. Its pathogenicity may be linked to the production of virulence factors. We isolated P. aeruginosa strain RBS from the saltern of Sfax in Tunisia. In this study, we characterized the halotolerance, antibiotic susceptibility, and some virulence factors of strain RBS. High NaCl concentrations inhibited growth and motility. However, biofilm formation was enhanced to protect bacteria against salt stress. Among the 18 antibiotics tested, quinolones and tetracycline showed a significant inhibitory effect on growth, motility, and biofilm formation of strain RBS. β-Lactams, however, did not have any inhibitory effect on neither bacterial growth nor motility. In some cases, resistance was due, in part, to biofilm formation. We also showed that RBS produces two proteases, LasB and AprA, which have been shown to be implicated in host infection. LasB was further characterized to study the role of metal ions in enzyme stability. It possesses two distinct metal ion-binding sites coordinating a calcium and a zinc ion. The effect of metal ion chelation was evaluated as well as substitutions of residues involved in metal ion binding. Impairing metal ion binding of LasB led to a loss of activity and a sharp decrease of stability. Our findings suggest that the binding of both metal ions is interdependent as the two metal ions' binding sites are linked via a hydrogen bond network.
Collapse
|
20
|
Anforderungen der Hygiene an abwasserführende Systeme in medizinischen Einrichtungen. Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz 2020; 63:484-501. [DOI: 10.1007/s00103-020-03118-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
21
|
Chia PY, Sengupta S, Kukreja A, S L Ponnampalavanar S, Ng OT, Marimuthu K. The role of hospital environment in transmissions of multidrug-resistant gram-negative organisms. Antimicrob Resist Infect Control 2020; 9:29. [PMID: 32046775 PMCID: PMC7014667 DOI: 10.1186/s13756-020-0685-1] [Citation(s) in RCA: 58] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2019] [Accepted: 01/23/2020] [Indexed: 12/12/2022] Open
Abstract
Infections by multidrug-resistant (MDR) Gram-negative organisms (GN) are associated with a high mortality rate and present an increasing challenge to the healthcare system worldwide. In recent years, increasing evidence supports the association between the healthcare environment and transmission of MDRGN to patients and healthcare workers. To better understand the role of the environment in transmission and acquisition of MDRGN, we conducted a utilitarian review based on literature published from 2014 until 2019.
Collapse
Affiliation(s)
- Po Ying Chia
- National Centre for Infectious Diseases, Jln Tan Tock Seng, Singapore.,Department of Infectious Diseases, Tan Tock Seng Hospital, Block H, CHI Level 3, 18, Jalan Tan Tock Seng, 308442, Singapore.,Lee Kong Chian School of Medicine, Nanyang Technological University, Nanyang, Singapore
| | - Sharmila Sengupta
- National Centre for Infectious Diseases, Jln Tan Tock Seng, Singapore
| | | | | | - Oon Tek Ng
- National Centre for Infectious Diseases, Jln Tan Tock Seng, Singapore.,Department of Infectious Diseases, Tan Tock Seng Hospital, Block H, CHI Level 3, 18, Jalan Tan Tock Seng, 308442, Singapore.,Lee Kong Chian School of Medicine, Nanyang Technological University, Nanyang, Singapore
| | - Kalisvar Marimuthu
- National Centre for Infectious Diseases, Jln Tan Tock Seng, Singapore. .,Department of Infectious Diseases, Tan Tock Seng Hospital, Block H, CHI Level 3, 18, Jalan Tan Tock Seng, 308442, Singapore. .,Yong Loo Lin School of Medicine, National University of Singapore, Kent Ridge Rd, Singapore.
| |
Collapse
|
22
|
A systematic review and meta-analysis of risk factors associated with acquisition of waterborne healthcare-associated infection or colonization in high-risk units. Infect Control Hosp Epidemiol 2019; 41:222-225. [DOI: 10.1017/ice.2019.326] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Abstract
In this meta-analysis, central venous catheter exposure (pooled odds ratio, 8.02; 95% confidence interval [CI], 2.19–29.31; P < .01) in neonates and length of stay (standardized mean difference, 0.65; 95% CI, 0.26–1.05; P = .01) in an adult population were associated with acquisition of waterborne healthcare-associated infections or colonization in ICUs. The quality of evidence was low.
Collapse
|
23
|
Changes of resistance rates in Pseudomonas aeruginosa strains are unrelated to antimicrobial consumption in ICU populations with invasive device-related infection. Med Intensiva 2019; 44:399-408. [PMID: 31787354 DOI: 10.1016/j.medin.2019.09.020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2019] [Revised: 08/29/2019] [Accepted: 09/22/2019] [Indexed: 12/13/2022]
Abstract
OBJECTIVE To evaluate the relationship between antipseudomonal antibiotic consumption and each individual drug resistance rate in Pseudomonas aeruginosa strains causing ICU acquired invasive device-related infections (IDRI). DESIGN A post hoc analysis was made of the data collected prospectively from the ENVIN-HELICS registry. SETTING Intensive Care Units participating in the ENVIN-UCI registry between the years 2007 and 2016 (3-month registry each year). PATIENTS Patients admitted for over 24h. MAIN VARIABLES Annual linear and nonlinear trends of resistance rates of P. aeruginosa strains identified in IDRI and days of treatment of each antipseudomonal antibiotic family per 1000 occupied ICU bed days (DOT) were calculated. RESULTS A total of 15,095 episodes of IDRI were diagnosed in 11,652 patients (6.2% out of a total of 187,100). Pseudomonas aeruginosa was identified in 2095 (13.6%) of 15,432 pathogens causing IDRI. Resistance increased significantly over the study period for piperacillin-tazobactam (P<0.001), imipenem (P=0.016), meropenem (P=0.004), ceftazidime (P=0.005) and cefepime (P=0.015), while variations in resistance rates for amikacin, ciprofloxacin, levofloxacin and colistin proved nonsignificant. A significant DOT decrease was observed for aminoglycosides (P<0.001), cephalosporins (P<0.001), quinolones (P<0.001) and carbapenems (P<0.001). CONCLUSIONS No significant association was observed between consumption of each antipseudomonal antibiotic family and the respective resistance rates for P. aeruginosa strains identified in IDRI.
Collapse
|
24
|
Ross B, Krull M, Rath P, Kribben A, Dopadlik D, Erlemann I, Wiegard-Szramek I, Tyczynski B, Buer J, Herbstreit F. Dialysis drains as a possible source for carbapenem-resistant pathogens causing an ICU outbreak. Infection 2018; 47:233-238. [PMID: 30465327 DOI: 10.1007/s15010-018-1239-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2018] [Accepted: 10/16/2018] [Indexed: 10/27/2022]
Abstract
OBJECTIVE DESIGN We describe a case series of patients colonized with KPC-producing Enterobacteriaceae related to dialysis drains at patient's bedside. SETTING The study was set at the intensive care unit (ICU) of a tertiary referral hospital. PATIENTS In March 2016, we discovered four ICU patients to be colonized with KPC-producing Enterobacteriaceae in routine screening. All of these patients had already received contact isolation, and all of them were treated with continuous veno-venous dialysis. Environmental examinations showed KPC-producing Enterobacteriaceae in dialysis drains in different ICU rooms and even in rooms not hosting KPC-colonized patients. INTERVENTIONS Based on our findings, we suspected the dialysis drains as a reservoir of KPC-producing Enterobacteriaceae with a potential risk for the patients. Therefore, we decided to change the dialysis waste management. RESULTS As a result, no KCP-producing Enterobacteriaceae were detected during the following weekly screening of the patients. CONCLUSIONS Installation of dialysis connection units including a drain system at the patient's bedside is a comfortable way to provide water supply. In many ICUs, such dialysis drains are installed near the patients' head and directly besides the infusion systems. When the drains are not used properly, in our opinion, they pose a risk of transmission of pathogens from the drain to the patient. Our findings support the need of specific precautions.
Collapse
Affiliation(s)
- Birgit Ross
- Krankenhaushygiene, Universitätsmedizin Essen, 45122, Essen, Germany.
| | - Marco Krull
- Krankenhaushygiene, Universitätsmedizin Essen, 45122, Essen, Germany
| | - Peter Rath
- Institut für Medizinische Mikrobiologie, Universität Duisburg-Essen and Universitätsklinikum Essen, Essen, Germany
| | - Andreas Kribben
- Klinik für Nephrologie, Universität Duisburg-Essen and Universitätsklinikum Essen, Essen, Germany
| | - Dana Dopadlik
- Krankenhaushygiene, Universitätsmedizin Essen, 45122, Essen, Germany
| | - Irmgard Erlemann
- Krankenhaushygiene, Universitätsmedizin Essen, 45122, Essen, Germany
| | - Ina Wiegard-Szramek
- Klinik für Nephrologie, Universität Duisburg-Essen and Universitätsklinikum Essen, Essen, Germany
| | - Bartosz Tyczynski
- Klinik für Nephrologie, Universität Duisburg-Essen and Universitätsklinikum Essen, Essen, Germany
| | - Jan Buer
- Institut für Medizinische Mikrobiologie, Universität Duisburg-Essen and Universitätsklinikum Essen, Essen, Germany
| | - Frank Herbstreit
- Klinik für Anästhesiologie and Intensivmedizin, Universität Duisburg-Essen and Universitätsklinikum Essen, Essen, Germany
| |
Collapse
|
25
|
Sink traps as the source of transmission of OXA-48-producing Serratia marcescens in an intensive care unit. Infect Control Hosp Epidemiol 2018; 39:1307-1315. [PMID: 30284524 DOI: 10.1017/ice.2018.235] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
BACKGROUND Carbapenemase-producing Enterobacteriaceae (CPE) outbreaks are mostly attributed to patient-to-patient transmission via healthcare workers. OBJECTIVE We describe successful containment of a prolonged OXA-48-producing S. marcescens outbreak after recognizing the sink traps as the source of transmission. METHODS The Sheba Medical Center intensive care unit (ICU), contains 16 single-bed, semi-closed rooms. Active CPE surveillance includes twice-weekly rectal screening of all patients. A case was defined as a patient detected with OXA-48 CPE >72 hours after admission. A root-cause analysis was used to investigate the outbreak. All samples were inoculated on chrom-agar CRE, and carbapenemase genes were detected using commercial molecular Xpert-Carba-R. Environmental and patient S. marcescens isolates were characterized using PFGE. RESULTS From January 2016 to May 2017, 32 OXA-48 CPE cases were detected, and 81% of these were S. marcescens. A single clone was the cause of all but the first 2 cases. The common factor in all cases was the use of relatively large amounts of tap water. The outbreak clone was detected in 2 sink outlets and 16 sink traps. In addition to routine strict infection control measures, measures taken to contain the outbreak included (1) various sink decontamination efforts, which eliminated the bacteria from the sink drains only temporarily and (2) educational intervention that engaged the ICU team and lead to high adherence to 'sink-contamination prevention guidelines.' No additional cases were detected for 12 months. CONCLUSIONS Despite persistence of the outbreak clones in the environmental reservoir for 1 year, the outbreak was rapidly and successfully contained. Addressing sink traps as hidden reservoirs played a major role in the intervention.
Collapse
|
26
|
How to: molecular investigation of a hospital outbreak. Clin Microbiol Infect 2018; 25:688-695. [PMID: 30287413 DOI: 10.1016/j.cmi.2018.09.017] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2017] [Revised: 09/19/2018] [Accepted: 09/23/2018] [Indexed: 12/11/2022]
Abstract
BACKGROUND Studying hospital outbreaks by using molecular tools, i.e. synthesizing the molecular epidemiology data to its appropriate clinical-epidemiologic context, is crucial in order to identify infection source, infer transmission dynamics, appropriately allocate prevention resources and implement control measures. Whole-genome sequencing (WGS) of pathogens has become the reference standard, as it is becoming more accessible and affordable. Consequently, sequencing of the full pathogen genome via WGS and major progress in fit-for-purpose genomic data analysis tools and interpretation is revolutionizing the field of outbreak investigations in hospitals. Metagenomics is an additional evolving field that might become commonly used in the future for outbreak investigations. Nevertheless, practitioners are frequently limited in terms of WGS or metagenomics, especially for local outbreak analyses, as a result of costs or logistical considerations, reduced or lack of locally available resources and/or expertise. As a result, traditional approaches, including pulsed-field gel electrophoresis, repetitive-element palindromic PCR and multilocus sequence typing, along with other typing methods, are still widely used. AIMS To provide practitioners with evidenced-based action plans for usage of the various typing techniques in order to investigate the molecular epidemiology of nosocomial outbreaks, of clinically significant pathogens in acute-care hospitals. SOURCES PubMed search with relevant keywords along with personal collection of relevant publications. CONTENT Representative case scenarios and critical review of the relevant scientific literature. IMPLICATIONS The review provides practical action plans to manage molecular epidemiologic investigations of outbreaks caused by clinically significant nosocomial pathogens, while prioritizing the use and timely integration of the various methodologies.
Collapse
|
27
|
Parkes LO, Hota SS. Sink-Related Outbreaks and Mitigation Strategies in Healthcare Facilities. Curr Infect Dis Rep 2018; 20:42. [PMID: 30128678 DOI: 10.1007/s11908-018-0648-3] [Citation(s) in RCA: 49] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
PURPOSE OF REVIEW In this review, we summarize recent outbreaks attributed to hospital sinks and examine design features and behaviors that contributed to these outbreaks. The effectiveness of various risk mitigation strategies is presented. Finally, we examine investigational strategies targeted at reducing the risk of sink-related infections. RECENT FINDINGS Outbreaks of hospital sink-related infections involve a diverse spectrum of microorganisms. They can be attributed to defects in sink design and hospital wastewater systems that promote the formation and dispersion of biofilm, as well as healthcare practitioner and patient behaviors. Risk mitigation strategies are often bundled; while they may reduce clinical cases, sink colonization may persist. Novel approaches targeting biofilms show promise but require more investigation. Emphasis should be placed on optimizing best practices in sink design and placement to prevent infections. Hospitals should consider developing a rational surveillance and prevention strategy based on the current design and state of their sinks.
Collapse
Affiliation(s)
- Leighanne O Parkes
- Department of Medicine, Division of Infectious Diseases, Jewish General Hospital, McGill University, Pavilion E-0054, 3755 Chemin de la Cote-Sainte-Catherine, Montreal, QC, H3T 1E2, Canada
| | - Susy S Hota
- Department of Medicine, Division of Infectious Diseases, University of Toronto, Toronto, ON, Canada.
- Department of Infection Prevention and Control, University Health Network, 9th Floor - 8 PMB 102, 585 University Avenue, Toronto, ON, M5G 2C4, Canada.
| |
Collapse
|
28
|
Efficacy of sodium hypochlorite against multidrug-resistant Gram-negative bacteria. J Hosp Infect 2018; 100:e40-e46. [PMID: 30026008 DOI: 10.1016/j.jhin.2018.07.017] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2018] [Accepted: 07/10/2018] [Indexed: 12/16/2022]
Abstract
BACKGROUND Increased antimicrobial resistance has been observed among many bacteria leading to treatment failures in human and veterinary medicine. Disinfection is a prerequisite for infection control and prevention in healthcare settings. Chlorine compounds are cost-effective and accessible worldwide. AIM To determine the efficacy of sodium hypochlorite (NaOCl) against multidrug-resistant Gram-negative bacteria (MDR-GNB). METHODS Minimum inhibitory concentrations (MICs) were determined using broth macro-dilution. Bactericidal efficacy was measured by qualitative and quantitative suspension tests followed by practical tests without mechanical action on stainless steel carriers. The guidelines of the German Association for Applied Hygiene were followed. FINDINGS Results varied remarkably depending on the method. MICs were 0.1% or 0.2% NaOCl. Qualitative suspension tests revealed up to 500-fold lower bactericidal concentrations. Pseudomonas aeruginosa (P = 0.0025) was significantly less susceptible in these tests whereas quantitative suspension tests revealed no significant differences between strains (P > 0.05). Practical tests determined bactericidal concentrations of 0.8-0.32% NaOCl at 1 min of contact and even lower concentrations for longer contact times. At 1 min, five Klebsiella were significantly less susceptible (P = 0.0124), whereas the lower susceptibility of P. aeruginosa was not confirmed. Organic load inhibited bactericidal activity significantly, whereas contact time had a marginal effect. Differing test results underline that MIC determination and qualitative suspension tests may be insufficient approaches to evaluate bacterial susceptibility or resistance. CONCLUSION NaOCl efficiently reduced Pseudomonas aeruginosa, Acinetobacter spp., and Klebsiella spp., most notably in the absence of organic matter. Strain- and species-specific differences in susceptibility were noticed, but in general MDR-GNB revealed no higher tolerance to NaOCl.
Collapse
|
29
|
Bellés A, Bueno J, Rojo-Bezares B, Torres C, Javier Castillo F, Sáenz Y, Seral C. Characterisation of VIM-2-producing Pseudomonas aeruginosa isolates from lower tract respiratory infections in a Spanish hospital. Eur J Clin Microbiol Infect Dis 2018; 37:1847-1856. [DOI: 10.1007/s10096-018-3318-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Accepted: 06/27/2018] [Indexed: 10/28/2022]
|
30
|
Tran-Dinh A, Neulier C, Amara M, Nebot N, Troché G, Breton N, Zuber B, Cavelot S, Pangon B, Bedos JP, Merrer J, Grimaldi D. Impact of intensive care unit relocation and role of tap water on an outbreak of Pseudomonas aeruginosa expressing OprD-mediated resistance to imipenem. J Hosp Infect 2018; 100:e105-e114. [PMID: 29857026 DOI: 10.1016/j.jhin.2018.05.016] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2018] [Accepted: 05/23/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND To assess the impact of the incidental relocation of an intensive care unit (ICU) on the risk of colonizations/infections with Pseudomonas aeruginosa exhibiting OprD-mediated resistance to imipenem (PA-OprD). AIM The primary aim was to compare the proportion of PA-OprD among P. aeruginosa samples before and after an incidental relocation of the ICU. The role of tap water as a route of contamination for colonization/infection of patients with PA-OprD was assessed as a secondary aim. METHODS A single-centre, observational, before/after comparison study was conducted from October 2013 to October 2015. The ICU was relocated at the end of October 2014. All P. aeruginosa-positive samples isolated from patients hospitalized ≥48 h in the ICU were included. Tap water specimens were collected every three months in the ICU. PA-OprD strains isolated from patients and tap water were genotyped using pulse-field gel electrophoresis. FINDINGS A total of 139 clinical specimens of P. aeruginosa and 19 tap water samples were analysed. The proportion of PA-OprD strains decreased significantly from 31% to 7.7% after the relocation of the ICU (P = 0.004). All PA-OprD clinical specimens had a distinct genotype. Surprisingly, tap water was colonized with a single PA-OprD strain during both periods, but this single clone has never been isolated from clinical specimens. CONCLUSION Relocation of the ICU was associated with a marked decrease in P. aeruginosa strains resistant to imipenem. The polyclonal character of PA-OprD strains isolated from patients and the absence of tap-water-to-patient contamination highlight the complexity of the environmental impact on the endogenous colonization/infection with P. aeruginosa.
Collapse
Affiliation(s)
- A Tran-Dinh
- Service de réanimation, 78150, Centre Hospitalier De Versailles, Le Chesnay, France; Département d'anesthésie et de réanimation chirurgicale, 75018, Centre Hospitalier de Bichat, Paris, France.
| | - C Neulier
- Service de Prévention du Risque Infectieux, Centre Hospitalier de Versailles, Le Chesnay, France
| | - M Amara
- Service de Biologie, Unité de microbiologie, 78157, Centre Hospitalier De Versailles, Le Chesnay, France
| | - N Nebot
- Service de pharmacie, 78150, Centre Hospitalier De Versailles, Le Chesnay, France
| | - G Troché
- Service de réanimation, 78150, Centre Hospitalier De Versailles, Le Chesnay, France
| | - N Breton
- Service de Prévention du Risque Infectieux, Centre Hospitalier de Versailles, Le Chesnay, France
| | - B Zuber
- Service de réanimation, 78150, Centre Hospitalier De Versailles, Le Chesnay, France
| | - S Cavelot
- Service de réanimation, 78150, Centre Hospitalier De Versailles, Le Chesnay, France
| | - B Pangon
- Service de Biologie, Unité de microbiologie, 78157, Centre Hospitalier De Versailles, Le Chesnay, France
| | - J P Bedos
- Service de réanimation, 78150, Centre Hospitalier De Versailles, Le Chesnay, France
| | - J Merrer
- Service de Prévention du Risque Infectieux, Centre Hospitalier de Versailles, Le Chesnay, France
| | - D Grimaldi
- Département de réanimation, CUB-Erasme, Université Libre de Bruxelles (ULB), Bruxelles, Belgium
| |
Collapse
|
31
|
Abstract
Although progress has been made in decreasing health care-associated infections (HAI) in intensive care unit (ICU) patients, there has been an increase in HAI caused by drug-resistant pathogens, particularly those that contaminate the environment such as methicillin-resistant Staphylococcus aureus, vancomycin-resistant Enterococcus, Pseudomonas spp, Acinetobacter spp, and Clostridium difficile. The ICU environment including sinks and medical equipment has been identified as being at risk for contamination and associated with cross-transmission of pathogens between the health care provider, the environment, and the patient. This article addresses the role of the ICU nurse as a team facilitator collaborating with environmental services, infection preventionists, and others to influence ICU design during preconstruction planning and unit environmental hygiene after construction to promote patient safety and prevent HAI associated with contaminated environments and equipment.
Collapse
|
32
|
Abstract
PURPOSE OF REVIEW Infectious disease outbreaks in the critical care setting are common and serious consequence. This article reviews and summarizes recent outbreaks in the adult ICUs. RECENT FINDINGS Outbreaks of multidrug-resistant bacteria, fungi, and emerging viruses in ICUs from different countries are common. Outbreak investigation relies on epidemiologic methods, microbiologic studies, and molecular typing methods. Overuse of antibiotics, gaps in implementing infection prevention measures, and contaminated environment are common causes of ICU outbreaks. ICU staff awareness of and preparedness for such outbreaks are crucial for outbreak prevention and control. Specific infection control measures vary according to outbreak transmission mode and cause. SUMMARY Outbreaks remain a significant threat to healthcare systems. Proper implementation of infection prevention practices and judicious use of antibiotics are needed for outbreak prevention in adult ICUs. Surveillance, proper outbreak investigation, adherence to infection prevention and control measures, and thorough disinfection of contaminated areas are required to successfully manage outbreaks.
Collapse
|
33
|
Shaw E, Gavaldà L, Càmara J, Gasull R, Gallego S, Tubau F, Granada RM, Ciercoles P, Dominguez MA, Mañez R, Carratalà J, Pujol M. Control of endemic multidrug-resistant Gram-negative bacteria after removal of sinks and implementing a new water-safe policy in an intensive care unit. J Hosp Infect 2017; 98:275-281. [PMID: 29104124 DOI: 10.1016/j.jhin.2017.10.025] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Accepted: 10/30/2017] [Indexed: 12/12/2022]
Abstract
BACKGROUND Contaminated handwashing sinks have been identified as reservoirs that can facilitate colonization/infection of patients with multidrug-resistant (MDR) Gram-negative bacteria (GNB) in intensive care units (ICUs). AIM To assess the impact of removing patients' sinks and implementing other water-safe strategies on the annual rates of ICU-acquired MDR-GNB. METHODS This six-year quasi-experimental study was conducted from January 2011 to December 2016. The intervention was carried out in August 2014 in two adult ICU wards with 12 rooms each. To assess the changes in annual MDR-GNB rates before and after the intervention, we used segmented regression analysis of an interrupted time-series. Crude relative risk (RR) rates were also calculated. FINDINGS The incidence rates of MDR-GNB were 9.15 and 2.20 per 1000 patient-days in the pre- and post-intervention periods, respectively. This yielded a crude RR of acquiring MDR-GNB of 0.24 (95% confidence interval: 0.17-0.34). A significant change in level was observed between the MDR-GNB rate at the first point of the post-intervention period and the rate predicted by the pre-intervention time trend. CONCLUSION The implementation of a new water-safe policy, which included the removal of sinks from all patient rooms, successfully improved the control of MDR-GNB spread in an ICU with endemic infection. Our results support the contribution of sink use with the incidence of MDR-GNB in endemic environments.
Collapse
Affiliation(s)
- E Shaw
- Department of Infectious Diseases, Hospital Universitari de Bellvitge-IDIBELL, Barcelona, Spain; Spanish Network for Research in Infectious Diseases, Instituto de Salud Carlos III, Madrid, Spain.
| | - L Gavaldà
- Department of Preventive Medicine, Hospital Universitari de Bellvitge-IDIBELL, Barcelona, Spain
| | - J Càmara
- Department of Microbiology, Hospital Universitari de Bellvitge-IDIBELL, Barcelona, Spain
| | - R Gasull
- Department of Intensive Medicine, Hospital Universitari de Bellvitge-IDIBELL, Barcelona, Spain
| | - S Gallego
- Department of Intensive Medicine, Hospital Universitari de Bellvitge-IDIBELL, Barcelona, Spain
| | - F Tubau
- Department of Microbiology, Hospital Universitari de Bellvitge-IDIBELL, Barcelona, Spain; CIBER de Enfermedades Respiratorias, Instituto de Salud Carlos III, Madrid, Spain
| | - R M Granada
- Department of Intensive Medicine, Hospital Universitari de Bellvitge-IDIBELL, Barcelona, Spain
| | - P Ciercoles
- Department of Infectious Diseases, Hospital Universitari de Bellvitge-IDIBELL, Barcelona, Spain
| | - M A Dominguez
- Department of Microbiology, Hospital Universitari de Bellvitge-IDIBELL, Barcelona, Spain; Spanish Network for Research in Infectious Diseases, Instituto de Salud Carlos III, Madrid, Spain; University of Barcelona, Barcelona, Spain
| | - R Mañez
- Department of Intensive Medicine, Hospital Universitari de Bellvitge-IDIBELL, Barcelona, Spain
| | - J Carratalà
- Department of Infectious Diseases, Hospital Universitari de Bellvitge-IDIBELL, Barcelona, Spain; Spanish Network for Research in Infectious Diseases, Instituto de Salud Carlos III, Madrid, Spain; University of Barcelona, Barcelona, Spain
| | - M Pujol
- Department of Infectious Diseases, Hospital Universitari de Bellvitge-IDIBELL, Barcelona, Spain; Spanish Network for Research in Infectious Diseases, Instituto de Salud Carlos III, Madrid, Spain
| |
Collapse
|
34
|
What Healthcare Workers Should Know about Environmental Bacterial Contamination in the Intensive Care Unit. BIOMED RESEARCH INTERNATIONAL 2017; 2017:6905450. [PMID: 29214175 PMCID: PMC5682046 DOI: 10.1155/2017/6905450] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2017] [Revised: 09/07/2017] [Accepted: 09/28/2017] [Indexed: 12/21/2022]
Abstract
Intensive care unit- (ICU-) acquired infections are a major health problem worldwide. Inanimate surfaces and equipment contamination may play a role in cross-transmission of pathogens and subsequent patient colonization or infection. Bacteria contaminate inanimate surfaces and equipment of the patient zone and healthcare area, generating a reservoir of potential pathogens, including multidrug resistant species. Traditional terminal cleaning methods have limitations. Indeed patients who receive a bed from prior patient carrying bacteria are exposed to an increased risk (odds ratio 2.13, 95% confidence intervals 1.62-2.81) of being colonized and potentially infected by the same bacterial species of the previous patient. Biofilm formation, even on dry surfaces, may play a role in reducing the efficacy of terminal cleaning procedures since it enables bacteria to survive in the environment for a long period and provides increased resistance to commonly used disinfectants. No-touch methods (e.g., UV-light, hydrogen peroxide vapour) are under investigation and further studies with patient-centred outcomes are needed, before considering them the standard of terminal cleaning in ICUs. Healthcare workers should be aware of the role of environmental contamination in the ICU and consider it in the broader perspective of infection control measures and stewardship initiatives.
Collapse
|
35
|
Lalancette C, Charron D, Laferrière C, Dolcé P, Déziel E, Prévost M, Bédard E. Hospital Drains as Reservoirs of Pseudomonas aeruginosa: Multiple-Locus Variable-Number of Tandem Repeats Analysis Genotypes Recovered from Faucets, Sink Surfaces and Patients. Pathogens 2017; 6:pathogens6030036. [PMID: 28792484 PMCID: PMC5617993 DOI: 10.3390/pathogens6030036] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2017] [Revised: 08/03/2017] [Accepted: 08/04/2017] [Indexed: 12/16/2022] Open
Abstract
Identifying environmental sources of Pseudomonas aeruginosa (Pa) related to hospital-acquired infections represents a key challenge for public health. Biofilms in water systems offer protection and favorable growth conditions, and are prime reservoirs of microorganisms. A comparative genotyping survey assessing the relationship between Pa strains recovered in hospital sink biofilm and isolated in clinical specimens was conducted. Environmental strains from drain, faucet and sink-surface biofilm were recovered by a culture method after an incubation time ranging from 48 to 240 h. The genotyping of 38 environmental and 32 clinical isolates was performed using a multiple-locus variable-number of tandem repeats analysis (MLVA). More than one-third of Pa isolates were only cultivable following ≥48 h of incubation, and were predominantly from faucet and sink-surface biofilms. In total, 41/70 strains were grouped within eight genotypes (A to H). Genotype B grouped a clinical and an environmental strain isolated in the same ward, 5 months apart, suggesting this genotype could thrive in both contexts. Genotype E grouped environmental isolates that were highly prevalent throughout the hospital and that required a longer incubation time. The results from the multi-hospital follow-up study support the drain as an important reservoir of Pa dissemination to faucets, sink surfaces and patients. Optimizing the recovery of environmental strains will strengthen epidemiological investigations, facilitate pathway identification, and assist in identifying and controlling the reservoirs potentially associated to hospital-acquired infections.
Collapse
Affiliation(s)
| | - Dominique Charron
- Department of Civil Engineering, Polytechnique Montréal, Montréal, QC H3T 1J4, Canada.
| | - Céline Laferrière
- Department of microbiology, infectious diseases and immunology, Université de Montréal, Montréal, QC H3T 1J4, Canada.
| | - Patrick Dolcé
- Department of Medical Microbiology and Infectious Diseases, Centre Hospitalier Régional de Rimouski, Rimouski, QC G5L 5T1, Canada.
| | - Eric Déziel
- INRS-Institut Armand-Frappier, Laval, QC H7V 1B7, Canada.
| | - Michèle Prévost
- Department of Civil Engineering, Polytechnique Montréal, Montréal, QC H3T 1J4, Canada.
| | - Emilie Bédard
- INRS-Institut Armand-Frappier, Laval, QC H7V 1B7, Canada.
- Department of Civil Engineering, Polytechnique Montréal, Montréal, QC H3T 1J4, Canada.
| |
Collapse
|
36
|
In vitro antimicrobial activity of LED irradiation on Pseudomonas aeruginosa. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY 2017; 168:25-29. [DOI: 10.1016/j.jphotobiol.2017.01.020] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2016] [Accepted: 01/20/2017] [Indexed: 12/12/2022]
|