1
|
Domingo-Jiménez T, González-Olmo MJ, Nieto-Moraleda C, Pérez-Chicharro M, Romero-Maroto M. Colourimetric changes experienced in three types of aligners according to the L'Eclairage Commission. Eur J Orthod 2024; 46:cjae047. [PMID: 39348237 DOI: 10.1093/ejo/cjae047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/02/2024]
Abstract
OBJECTIVE The objective was to compare the colourimetric increment (L*, a*, and b*) of three types of aligners after subjecting them to two stains and to evaluate the initial colourimetric characteristics. METHODS A total of 120 aligners (40 Invisalign®, 40 Spark®, and 40 QuickSmile®) were immersed in two different agents (distilled water and coffee). Measurements were taken using a spectrophotometer before immersion (T0), after 12 hours (T1), and after 7 days (T2). Colour changes (ΔE*) were evaluated based on the International Commission of L'Eclairage, and subsequently converted to National Bureau of Standards units. The measurement was repeated three times. The intraclass correlation coefficient, one-way ANOVA, Tukey's post hoc test, and the independent t test were used (P ≤ .05). RESULTS At T0, significant differences were observed for a*: Invisalign® and Spark® tended towards redder tones, whereas Quicksmile® leaned towards greener shades. Regarding b*, all aligners tended towards yellow, with Invisalign® exhibiting the least tendency. No differences were found in water between T1 and T0. In the intervals, T2-T1 and T2-T0, Spark® showed more noticeable changes, whereas for Invisalign® and Quicksmile®, the change was only slight. In coffee, a shift to another colour was detected in T1-T0, T2-T1, and T2-T0 for Invisalign®, whereas for other brands, it was barely noticeable except for T2-T0 in Spark®, where the change was appreciable. In coffee, Invisalign® tended towards darker values (L*), turning redder (a*), and more yellow (b*) in T2-T1 and T2-T0. CONCLUSIONS Invisalign® aligners initially presented a more reddish and less yellowish colour. In water, after 7 days, a noticeable colour change was found for Spark®. In coffee, a greater loss in brightness and a change to red and yellow were observed after 12 hours and 7 days for Invisalign®. This study highlights the importance of considering the impact of coffee on the colouring of aligners, especially with Invisalign®, which shows more noticeable changes.
Collapse
Affiliation(s)
- Teresa Domingo-Jiménez
- Department of Orthodontics, University Rey Juan Carlos, Alcorcón, CP 28922, Madrid, Spain
| | | | | | - María Pérez-Chicharro
- Department of Orthodontics, University Rey Juan Carlos, Alcorcón, CP 28922, Madrid, Spain
| | - Martin Romero-Maroto
- Department of Orthodontics, University Rey Juan Carlos, Alcorcón, CP 28922, Madrid, Spain
| |
Collapse
|
2
|
Nicita F, D'Amico C, Filardi V, Spadaro D, Aquilio E, Mancini M, Fiorillo L. Chemical-Physical Characterization of PET-G-Based Material for Orthodontic Use: Preliminary Evaluation of micro-Raman Analysis. Eur J Dent 2024; 18:228-235. [PMID: 37247624 PMCID: PMC10959632 DOI: 10.1055/s-0043-1764424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/31/2023] Open
Abstract
OBJECTIVES Orthodontic treatment with clear thermoplastic aligners is in great demand by patients especially for aesthetics. Any alterations in the chemical composition of the thermoplastic material for aligners, subjected to the oral environment and exposure to various commonly used substances, could influence the desired orthodontic movement decreasing the predictability of the treatment. The objective of this study was to determine the chemical-physical characterization by micro-Raman spectroscopy of a thermoplastic material based on polyethylene terephthalate glycol (PET-G) used for the manufacture of Lineo aligners (Micerium Lab, Avegno, Italy) subjected to different staining beverages and cleaning agents. MATERIALS AND METHODS Twenty-two thermoformed PET-G samples were immersed to various substances of daily use for 10 and 15 days (coffee, tea, Coca-Cola, red wine, colloidal silver disinfectant, nicotine, artificial saliva, cigarette smoke, and different combinations of saliva with some of the previous solutions). Subsequently, the chemical-physical characterization was investigated by micro-Raman spectroscopy. RESULTS The analysis of the spectra acquired for all the specimens showed no difference in the exposure to the different solvents at 10 and 15 days. Furthermore, having ascertained the heterogeneous surface morphology of the PET-G material due to thermoforming, various deposits were present on all the samples whose consistency and concentration depended on the substance used. CONCLUSION The spectroscopic investigations have provided a precise and detailed analysis of the qualitative and structural data of the PET-G material under examination. No significant structural modifications of the thermoplastic polymer were found after immersion in different solutions in the exposure times adopted.
Collapse
Affiliation(s)
- Fabiana Nicita
- Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, via Consolare Valeria, Messina, Italy
| | - Cesare D'Amico
- Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, via Consolare Valeria, Messina, Italy
| | - Vincenzo Filardi
- D.A. Research and Internationalization, University of Messina, Via Consolato del mare 41, Messina, Italy
| | | | | | - Maura Mancini
- Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, via Consolare Valeria, Messina, Italy
| | - Luca Fiorillo
- Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, via Consolare Valeria, Messina, Italy
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania Luigi Vanvitelli, Naples, Italy
| |
Collapse
|
3
|
Yan J, Cao L, Luo T, Qin D, Hua F, He H. In vitro evaluation of a novel fluoride-coated clear aligner with antibacterial and enamel remineralization abilities. Clin Oral Investig 2023; 27:6027-6042. [PMID: 37620439 DOI: 10.1007/s00784-023-05216-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Accepted: 08/14/2023] [Indexed: 08/26/2023]
Abstract
OBJECTIVE To investigate the antibacterial and enamel remineralization performances as well as physicochemical properties and biocompatibility of a fluoride-coated clear aligner plastic (FCAP). MATERIALS AND METHODS FCAP and normal clear aligner plastic (CAP) was bought from the manufacturer (Angelalign Technology Inc, China). The FCAP was observed under scanning electron microscopy. Its element composition, resistance to separation, contact angle, and protein adhesion performance were characterized. Colony-forming unit (CFU) count and 3-(4,5)-dimethylthiazol(-z-y1)-3,5-diphenyltetrazolium bromide (MTT) assay were used to evaluate the antibacterial ability of Streptococcus mutans. Fluoride release-recharge patterns were obtained. Apatite formation was evaluated after immersing FCAP in artificial saliva. Enamel remineralization capability was evaluated in the demineralization model (immersing samples in demineralization solution for 36 h) and pH cycling model (immersing samples in demineralization solution and remineralization solution in turns for 14 days). Cell Counting Kit-8 (CCK-8) and live/dead cell staining kits were used for cytotoxicity assay. RESULTS The FCAP showed uniformly distributed fluoride and did not compromise protein adhesion performance. CFU count (5.47 ± 0.55 for CAP, 3.63 ± 0.38 for FCAP) and MTT assay (0.41 ± 0.025 for CAP, 0.28 ± 0.038) indicated that the FCAP had stronger antibacterial activity compared with normal CAP (P < 0.05 for both evaluations). The FCAP could release fluoride continuously for 14 days and could be recharged after immersing in NaF solution. The FCAP could induce the formation of hydroxyapatite in artificial saliva and could reduce the microhardness decrease, color change, and mineral loss of enamels in both two models (P < 0.05 for all evaluations). CCK-8 and live/dead cell staining analyses showed that the coating did not compromise the biocompatibility of the clear aligner (P > 0.05 for CCK-8 evaluation). CONCLUSIONS The FCAP had antibacterial, fluoride recharge, and enamel remineralization abilities while it did not compromise physicochemical properties and biocompatibility. CLINICAL RELEVANCE The FCAP has the potential to prevent enamel demineralization during clear aligner treatment.
Collapse
Affiliation(s)
- Jiarong Yan
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China
- Department of Orthodontics, School & Hospital of Stomatology, Wuhan University, Wuhan, China
| | - Lingyun Cao
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China
- Department of Orthodontics, School & Hospital of Stomatology, Wuhan University, Wuhan, China
| | - Ting Luo
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China
- Department of Orthodontics, School & Hospital of Stomatology, Wuhan University, Wuhan, China
| | - Danchen Qin
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China
- Department of Orthodontics, School & Hospital of Stomatology, Wuhan University, Wuhan, China
| | - Fang Hua
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China.
- Center for Orthodontics and Pediatric Dentistry at Optics Valley Branch, School & Hospital of Stomatology , Wuhan University, Wuhan, China.
- Division of Dentistry, School of Medical Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK.
| | - Hong He
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China.
- Department of Orthodontics, School & Hospital of Stomatology, Wuhan University, Wuhan, China.
| |
Collapse
|
4
|
Rouzi M, Zhang X, Jiang Q, Long H, Lai W, Li X. Impact of Clear Aligners on Oral Health and Oral Microbiome During Orthodontic Treatment. Int Dent J 2023; 73:603-611. [PMID: 37105789 PMCID: PMC10509397 DOI: 10.1016/j.identj.2023.03.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 03/19/2023] [Accepted: 03/27/2023] [Indexed: 04/29/2023] Open
Abstract
The demand for clear aligners has risen over the past decade because they satisfy patients' desire for less noticeable and more comfortable orthodontic appliances. Because clear aligners are increasingly used in orthodontics, there is a big push to learn more about the physiologic and microbial changes that occur during treatment. The present work highlighted further links between clear aligners and changes in oral health and the oral microbiome and provided plaque control methods for clear aligner trays. Existing literature revealed that clear aligners have no significant influence on the structure of the oral microbiome during orthodontic therapy. Clear aligner treatment demonstrated promising results in terms of controlling plaque index, gingival health, and the prevalence of white spot lesions. Nevertheless, grooves, ridges, microcracks, and abrasions on the aligner surface would provide a prime environment for bacterial adherence and the development of plaque biofilms. A combination of mechanical and chemical methods seems to be a successful approach for removing plaque biofilm from aligners whilst also preventing pigment adsorption.
Collapse
Affiliation(s)
- Maierdanjiang Rouzi
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China School of Stomatology, Sichuan University, Chengdu, China
| | - Xiaoqi Zhang
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China School of Stomatology, Sichuan University, Chengdu, China
| | - Qingsong Jiang
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China School of Stomatology, Sichuan University, Chengdu, China
| | - Hu Long
- Department of Orthodontics, State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Wenli Lai
- Department of Orthodontics, State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China.
| | - Xiaolong Li
- Department of Orthodontics, State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China.
| |
Collapse
|
5
|
Chen SM, Ho CT, Huang TH, Kao CT. An in vitro evaluation of aligner force decay in artificial saliva. J Dent Sci 2023; 18:1347-1353. [PMID: 37404637 PMCID: PMC10316483 DOI: 10.1016/j.jds.2023.04.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 04/18/2023] [Indexed: 07/06/2023] Open
Abstract
Background/purpose The present study aimed to compare the force decay of invisible aligners for maxillary anterior teeth with 0.1 mm (D1), 0.2 mm (D2), and 0.3 mm (D3) labial movement within a simulated oral environment over 7 days. Materials and methods The prepared invisible aligners were immersed in saliva (S) and subjected to applied force (F) for 7 days. The aligners were set and placed on the maxillary right central incisor with 0.1 mm (D1), 0.2 mm (D2), and 0.3 mm (D3) labial movement. Thin-film pressure sensors were used to measure the aligner force changes. The data were collected and analyzed by statistical methods. Results Significant differences were observed in the initial and first-day force between the D2 and D3 groups under simulated oral environment force (SF) (P < 0.05). There was a significant difference in force decay between Day 1 and Day 7 for all groups (P < 0.05). The SFD1 group showed a significant decrease in force on Day 5 (P < 0.05), while the SFD2 and SFD3 groups showed significant force decay on Day 4 (P < 0.05). The force decay ratio on Day 7 was higher in the SFD3 group than in the SFD1 and SFD2 groups, but no significant difference was observed. Conclusion Larger labial movement of the aligners resulted in higher force decay under artificial saliva environments, and the force decay of invisible aligners was increased by immersion time in artificial saliva.
Collapse
Affiliation(s)
- Shou-Min Chen
- School of Dentistry, College of Oral Medicine, Chung Shan Medical University, Taichung, Taiwan
- Orthodontic Department, Chung Shan Medical University Hospital, Taichung, Taiwan
| | - Chun-Te Ho
- School of Dentistry, College of Oral Medicine, Chung Shan Medical University, Taichung, Taiwan
- Orthodontic Department, Chung Shan Medical University Hospital, Taichung, Taiwan
| | - Tsui-Hsein Huang
- School of Dentistry, College of Oral Medicine, Chung Shan Medical University, Taichung, Taiwan
- Dental Department, Chung Shan Medical University Hospital, Taichung, Taiwan
| | - Chia-Tze Kao
- Orthodontic Department, Chung Shan Medical University Hospital, Taichung, Taiwan
- Dental Department, Chung Shan Medical University Hospital, Taichung, Taiwan
| |
Collapse
|
6
|
Quinzi V, Orilisi G, Vitiello F, Notarstefano V, Marzo G, Orsini G. A spectroscopic study on orthodontic aligners: First evidence of secondary microplastic detachment after seven days of artificial saliva exposure. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 866:161356. [PMID: 36603638 DOI: 10.1016/j.scitotenv.2022.161356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Revised: 12/20/2022] [Accepted: 12/30/2022] [Indexed: 06/17/2023]
Abstract
Clear orthodontic aligners have recently seen increasing popularity. The thermoplastic materials present several advantages, even if it is known that all plastic products can be subjected to environmental and mechanical degradation, leading to the release of microplastics (MPs). Their ingestion could cause oxidative stress and inflammatory lesions. This study aims to evaluate the potential detachment of MPs by clear aligners due to mechanical friction simulated with a 7-day protocol in artificial saliva. The study was performed on orthodontic clear aligners from different manufacturers: Alleo (AL); FlexiLigner (FL); F22 Aligner (F22); Invisalign® (INV); Lineo (LIN); Arc Angel (ARC), and Ortobel Aligner (OR). For each group, two aligners were immersed in artificial saliva for 7 days and stirred for 5 h/day, simulating the physiological teeth mechanical friction. After 7 days, the artificial saliva was filtered; then, filters were analyzed by Raman Microspectroscopy (RMS) and Scanning Electron Microscopy (SEM), respectively to chemically identify the polymeric matrix and to measure the number and size of the detected MPs. RMS spectra revealed that AL, FL, LIN, ARC, and OR aligners were composed by polyethylene terephthalate, while F22 and INV ones by polyurethane. SEM analysis showed that the highest number of MPs was found in ARC and the lowest in INV (p < 0.05). As regards MPs' size, no statistically significant difference was found among groups, with most MPs ranging from 5 to 20 μm. Noteworthy, a highly significant correlation (p < 0.0001) was highlighted between the distribution of MPs size and the different typologies of aligners. This in vitro study highlighted for the first time the detachment of MPs from clear aligners due to mechanical friction. This evidence may represent a great concern in the clinical practice since it could impact human general health.
Collapse
Affiliation(s)
- Vincenzo Quinzi
- Università degli Studi dell'Aquila, Dipartimento di Medicina Clinica, Sanità Pubblica, Scienze della Vita e dell'Ambiente, Piazza Salvatore Tommasi, 67100 L'Aquila, Italy
| | - Giulia Orilisi
- Università Politecnica delle Marche, Dipartimento di Scienze Cliniche Specialistiche ed Odontostomatologiche, Via Tronto 10, 60126 Ancona, Italy
| | - Flavia Vitiello
- Università Politecnica delle Marche, Dipartimento di Scienze Cliniche Specialistiche ed Odontostomatologiche, Via Tronto 10, 60126 Ancona, Italy
| | - Valentina Notarstefano
- Università Politecnica delle Marche, Dipartimento di Scienze della Vita e dell'Ambiente, Via Brecce Bianche, 60131 Ancona, Italy
| | - Giuseppe Marzo
- Università degli Studi dell'Aquila, Dipartimento di Medicina Clinica, Sanità Pubblica, Scienze della Vita e dell'Ambiente, Piazza Salvatore Tommasi, 67100 L'Aquila, Italy
| | - Giovanna Orsini
- Università Politecnica delle Marche, Dipartimento di Scienze Cliniche Specialistiche ed Odontostomatologiche, Via Tronto 10, 60126 Ancona, Italy.
| |
Collapse
|
7
|
Butera A, Gallo S, Pascadopoli M, Sfondrini B, Alovisi M, Marya A, Stablum G, Scribante A. Assessment of the Bacterial Loads of Vacuum-Thermoformed Removable Retainers (VTRR) in Patients under Retention Therapy: A Randomized Clinical Trial. Healthcare (Basel) 2022; 10:1239. [PMID: 35885766 PMCID: PMC9319364 DOI: 10.3390/healthcare10071239] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 06/29/2022] [Accepted: 07/01/2022] [Indexed: 11/16/2022] Open
Abstract
Retention devices are essential after orthodontic treatment in order to avoid the risk of relapse. For this goal, vacuum-thermoformed removable retainers (VTRRs) are useful tools in clinical practice. The main limitation related to them is the accumulation of plaque. The aim of this study was to investigate the bacterial loads present on VTRRs (Essix ACE Plastic, Dentsply Sirona) in patients under retention therapy. Patients were randomly divided into three groups, depending on the product used for the cleansing of the VTRR: Geldis, Polident tablets, and simple water, respectively. Microbiological samples were taken from the retainers at the baseline, after 1 and after 2 months, with the collection of Bleeding on Probing (BoP), Plaque Index (PI), Basic Erosive Wear Examination (BEWE) and Schiff Air Sensitivity test (SAI). A total of 15 patients were recruited and for each product, 5 patients were allocated. No significant intragroup and intergroup differences were observed at any time point for PI, SAI, BoP, Red Complex, Total Pathogen and Total Saprophyte loads. A significant intragroup and intergroup difference was assessed at T1 and T2 for BEWE in the control group. According to the results of this study, the bacterial load on VTRR retainers is not influenced by the cleaning methods tested.
Collapse
Affiliation(s)
- Andrea Butera
- Unit of Dental Hygiene, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy; (A.B.); (G.S.)
| | - Simone Gallo
- Unit of Orthodontics and Pediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy;
| | - Maurizio Pascadopoli
- Unit of Orthodontics and Pediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy;
| | - Beatrice Sfondrini
- Unit of Orthodontics and Pediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy;
| | - Mario Alovisi
- Department of Surgical Sciences, Dental School, University of Turin, 0121 Turin, Italy;
| | - Anand Marya
- Department of Orthodontics, Faculty of Dentistry, University of Puthisastra, Phnom Penh 12211, Cambodia;
- Center for Transdisciplinary Research, Saveetha Institute of Medical and Technical Science, Saveetha Dental College, Saveetha University, Chennai 600077, India
| | - Giulia Stablum
- Unit of Dental Hygiene, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy; (A.B.); (G.S.)
| | - Andrea Scribante
- Unit of Dental Hygiene, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy; (A.B.); (G.S.)
- Unit of Orthodontics and Pediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy;
| |
Collapse
|
8
|
Charavet C, Gourdain Z, Graveline L, Lupi L. Cleaning and Disinfection Protocols for Clear Orthodontic Aligners: A Systematic Review. Healthcare (Basel) 2022; 10:healthcare10020340. [PMID: 35206954 PMCID: PMC8871989 DOI: 10.3390/healthcare10020340] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2022] [Revised: 02/03/2022] [Accepted: 02/07/2022] [Indexed: 01/25/2023] Open
Abstract
(1) Background: Clear orthodontic aligners support the development of oral biofilms, which could lead to interferences with the oral microbiota already existing and the deterioration of oral health, with the development of dental caries, periodontal disease and even systemic infections. Therefore, preventive oral health care requires a cleaning and disinfection procedure for aligners. (2) Methods: A systematic review of the literature was conducted across four databases following the PRISMA guidelines up to May 2021, combining an electronic and a manual search. Prospective studies, including randomized controlled trials (RCTs), crossover studies (COSs) and controlled clinical trials (CCTs), published in the English language without time restrictions, evaluating the efficacy of cleaning and disinfection protocols for clear orthodontic aligners by comparing them with a placebo or a negative control, were included. The article selection, data extraction and risk of bias assessment were performed by two independent blinded review authors. In case of disagreement, a third author was solicited throughout the selection process. (3) Results: Among the 221 articles screened in the search process, 4 studies were included in the review, all designed as crossover studies (single arm without randomization with the same sequence of different cleaning and disinfection protocols for each participant). Different cleaning and disinfection methods were studied such as mechanical methods (brushing with toothpaste or vibration), chemical methods/pharmaceutical products (chlorhexidine antibacterial substance, anionic or cationic detergents or effervescent tablets) or combinations of both. (4) Conclusion: Although the determination of the most remarkable method of cleaning and disinfection was impossible because no direct comparison was conducted between all these methods, a multi-step protocol, including the combination of a mechanical and a chemical method, seems to be the most effective approach. Further research is needed to define the most preventive oral health care protocol. Registration: PROSPERO CRD 42021278498.
Collapse
Affiliation(s)
- Carole Charavet
- Université Côte d’Azur, Faculté de Chirurgie Dentaire, Département d’Orthodontie, 06800 Nice, France
- Centre Hospitalier Universitaire de Nice, Pôle Odontologie, 06000 Nice, France; (Z.G.); (L.G.)
- Laboratoire MICORALIS UPR 7354, Université Côte d’Azur, 06800 Nice, France
- Correspondence: or
| | - Zoé Gourdain
- Centre Hospitalier Universitaire de Nice, Pôle Odontologie, 06000 Nice, France; (Z.G.); (L.G.)
- Université Côte d’Azur, Faculté de Chirurgie Dentaire, 06800 Nice, France
| | - Léa Graveline
- Centre Hospitalier Universitaire de Nice, Pôle Odontologie, 06000 Nice, France; (Z.G.); (L.G.)
- Université Côte d’Azur, Faculté de Chirurgie Dentaire, 06800 Nice, France
| | - Laurence Lupi
- Centre Hospitalier Universitaire de Nice, Pôle Odontologie, 06000 Nice, France; (Z.G.); (L.G.)
- Laboratoire MICORALIS UPR 7354, Université Côte d’Azur, 06800 Nice, France
- Université Côte d’Azur, Faculté de Chirurgie Dentaire, Département de Santé Publique, 06800 Nice, France;
| |
Collapse
|
9
|
The force effects of two types of polyethylene terephthalate glyc-olmodified clear aligners immersed in artificial saliva. Sci Rep 2021; 11:10052. [PMID: 33980889 PMCID: PMC8115163 DOI: 10.1038/s41598-021-89425-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Accepted: 04/20/2021] [Indexed: 11/08/2022] Open
Abstract
Numerous factors can influence the force exerted by clear aligners on teeth. This study aimed to investigate the stability of the force delivered by two different material appliances. 90 clear aligners with 2 materials and three different activations were designed and fabricated. Then, a device was employed to measure the force generated by the two types of PET-G material appliances immersed in artificial saliva for 0, 3, 7, 10, 14 days. Scanning electron microscopy was applied to observe the morphologic alterations on the aligner surfaces, respectively. The forces generated by different activation appliance exhibited differently, 0.0 mm < 0.1 mm < 0.2 mm. In addition, increasing the immersion times and the orthodontic force also decreased, but the forces decreased differently. Compared with the forces of conventional PETG appliances with 0.20 mm activation, the modified PETG appliances with the same activation exhibited significantly higher mean force. When comparing the mean force for modified PETG appliances after 10 and 14 days with conventional PETG appliances, the delivery forces exhibited significant differences (P < 0.05). The force delivered by both materials decreased obviously following artificial saliva immersion, and the force generated by modified aligners exhibited better stability than conventional aligners.
Collapse
|
10
|
Putrino A, Barbato E, Galluccio G. Clear Aligners: Between Evolution and Efficiency-A Scoping Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18062870. [PMID: 33799682 PMCID: PMC7998651 DOI: 10.3390/ijerph18062870] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Revised: 02/18/2021] [Accepted: 03/02/2021] [Indexed: 12/21/2022]
Abstract
In recent years, clear aligners have diversified and evolved in their primary characteristics (material, gingival margin design, attachments, divots, auxiliaries), increasing their indications and efficiency. We overviewed the brands of aligners used in Italy and reviewed the literature on the evolution of clear aligners based on their characteristics mentioned above by consulting the main scientific databases (PubMed, Scopus, Lilacs, Google Scholar, Cochrane Library). Inclusion and exclusion criteria were established. The data were collected on a purpose-made data collection form and analyzed descriptively. From the initial 580 records, 527 were excluded because they were not related to the subject of the review or because they did not meet the eligibility criteria. The remaining 31 studies were deemed comprehensive for the purpose of the review, although the “gingival margin design” feature and “auxiliaries” tool are not well represented in the more recent literature. Current knowledge on invisible aligners allows us to have a much clearer idea of the basic characteristics of aligner systems. There remains a need to deepen the use of systems other than Invisalign™ to give greater evidence to aligners that are very different based on the characteristics analyzed here and that are very widespread on the market.
Collapse
|
11
|
Bernard G, Rompré P, Tavares JR, Montpetit A. Colorimetric and spectrophotometric measurements of orthodontic thermoplastic aligners exposed to various staining sources and cleaning methods. Head Face Med 2020; 16:2. [PMID: 32070379 PMCID: PMC7027305 DOI: 10.1186/s13005-020-00218-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2019] [Accepted: 02/12/2020] [Indexed: 11/25/2022] Open
Abstract
Background Manufacturers of orthodontic aligners suggest that users remove appliances every time they consume solid foods or any drink (except water). This is to avoid a color change within the clear thermoplastic material of which they are made. However, limited quantitative evidence exists to guide users and practitioners in this regard. Herein, we evaluated the color stability of the polymer forming three different American brands of aligners and the stain-removal potential of two cleansers to provide such guidelines. Methods The removable appliances (300 specimens, 100 per brand) were exposed to different staining agents common in a regular diet (coffee, black tea, red wine, cola) or to a control solution in vitro over 12 h or 7 days. The three brands evaluated were Invisalign®, ClearCorrect® and Minor Tooth Movement®. These were then cleaned by using either Invisalign® cleaning crystals or the Cordless Sonic Cleaner combined with a Retainer Brite® tablet. The CIELAB color space approach was used to compare color changes (ΔE) in aligners before immersion (T0), after a 12-h exposure (T1), after a 7-day exposure (T2) and after cleaning (T3). Statistical methods (Levene’s test, ANOVA, Brunner-Langer model, Tukey’s range test and t-test) were used to identify interactions between the brands themselves or between the brands and the cleaning methods. Statistical analyses were performed at the .05 significance level. Results A 12-h or 7-day exposure to instant coffee or red wine significantly colored the Invisalign® aligners compared to the two other brands. Black tea created an important extrinsic color change for all three brands after 7 days. Clinically, both cleaning methods showed a better efficacy in removing stains from black tea compared to other staining agents. Conclusions The Invisalign® aligners were more prone to pigmentation than the ClearCorrect® or the Minor Tooth Movement® devices after an exposure to coffee or red wine. Black tea caused important stains on the surface of the three tested brands. Both cleansing methods performed similarly.
Collapse
Affiliation(s)
- Gabrielle Bernard
- Department of Oral Health - Orthodontics Section, Faculty of Dental Medicine, Université de Montréal, Québec, Canada
| | - Pierre Rompré
- Department of Oral Health - Orthodontics Section, Faculty of Dental Medicine, Université de Montréal, Québec, Canada
| | - Jason Robert Tavares
- CREPEC, Department of Chemical Engineering, Polytechnique Montréal, P.O. Box 6079, Stat. Centre-Ville, Montréal, Québec, H3C 3A7, Canada.
| | - Andrée Montpetit
- Department of Oral Health - Orthodontics Section, Faculty of Dental Medicine, Université de Montréal, Québec, Canada
| |
Collapse
|
12
|
Vyas N, Manmi K, Wang Q, Jadhav AJ, Barigou M, Sammons RL, Kuehne SA, Walmsley AD. Which Parameters Affect Biofilm Removal with Acoustic Cavitation? A Review. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:1044-1055. [PMID: 30792088 DOI: 10.1016/j.ultrasmedbio.2019.01.002] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Revised: 01/01/2019] [Accepted: 01/04/2019] [Indexed: 06/09/2023]
Abstract
Bacterial biofilms are a cause of contamination in a wide range of medical and biological areas. Ultrasound is a mechanical energy that can remove these biofilms using cavitation and acoustic streaming, which generate shear forces to disrupt biofilm from a surface. The aim of this narrative review is to investigate the literature on the mechanical removal of biofilm using acoustic cavitation to identify the different operating parameters affecting its removal using this method. The properties of the liquid and the properties of the ultrasound have a large impact on the type of cavitation generated. These include gas content, temperature, surface tension, frequency of ultrasound and acoustic pressure. For many of these parameters, more research is required to understand their mechanisms in the area of ultrasonic biofilm removal, and further research will help to optimise this method for effective removal of biofilms from different surfaces.
Collapse
Affiliation(s)
- Nina Vyas
- School of Dentistry, College of Medical and Dental Sciences, University of Birmingham, Birmingham, United Kingdom
| | - Kawa Manmi
- School of Mathematics, College of Engineering and Physical Sciences, University of Birmingham, Birmingham, United Kingdom
| | - Qianxi Wang
- School of Mathematics, College of Engineering and Physical Sciences, University of Birmingham, Birmingham, United Kingdom
| | - Ananda J Jadhav
- School of Chemical Engineering, College of Engineering and Physical Sciences, University of Birmingham, Birmingham, United Kingdom
| | - Mostafa Barigou
- School of Chemical Engineering, College of Engineering and Physical Sciences, University of Birmingham, Birmingham, United Kingdom
| | - Rachel L Sammons
- School of Dentistry, College of Medical and Dental Sciences, University of Birmingham, Birmingham, United Kingdom
| | - Sarah A Kuehne
- School of Dentistry, College of Medical and Dental Sciences, University of Birmingham, Birmingham, United Kingdom
| | - A Damien Walmsley
- School of Dentistry, College of Medical and Dental Sciences, University of Birmingham, Birmingham, United Kingdom.
| |
Collapse
|