1
|
Kim Y, Karl E, Ishijima M, Guy S, Jacquet C, Ollivier M. The Potential of Tendon Autograft as Meniscus substitution: Current concepts. J ISAKOS 2024:100353. [PMID: 39427818 DOI: 10.1016/j.jisako.2024.100353] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2024] [Revised: 10/01/2024] [Accepted: 10/16/2024] [Indexed: 10/22/2024]
Abstract
Meniscectomy is known to alter the mechanics, stability, and kinematics of the tibiofemoral joint, leading to early knee osteoarthritis (KOA). While several meniscal substitutions exist, such as meniscus allograft transplantation, collagen meniscus implants, and artificial substitutes, they often come with technical challenges, high costs, and risks, including allograft failure, infections, and disease transmission. Tendon autografts emerge as a promising option, offering safety, availability, biocompatibility, and a reduced risk of pathophoresis. This review delves into basic, in vivo, in vitro, and biomechanical studies alongside clinical outcomes and future prospects of tendon autografts as meniscus substitutes. A thorough understanding of this option is vital for integrating these evolving techniques into clinical practice and mitigating early KOA progression.
Collapse
Affiliation(s)
- Youngji Kim
- Department of Orthopaedics, Juntendo University, Faculty of Medicine, Tokyo, Japan; Institut du Mouvement et de l'appareil locomoteur, Hôpital Sainte-Marguerite, Aix-Marseille Université, Marseille, France
| | - Eriksson Karl
- Department of Orthopaedics, Stockholm South Hospital, Institution for clinical science and education, Karolinska Institutet, Stockholm, Sweden
| | - Muneaki Ishijima
- Department of Orthopaedics, Juntendo University, Faculty of Medicine, Tokyo, Japan
| | - Sylvain Guy
- Institut du Mouvement et de l'appareil locomoteur, Hôpital Sainte-Marguerite, Aix-Marseille Université, Marseille, France
| | - Christophe Jacquet
- Institut du Mouvement et de l'appareil locomoteur, Hôpital Sainte-Marguerite, Aix-Marseille Université, Marseille, France
| | - Matthieu Ollivier
- Institut du Mouvement et de l'appareil locomoteur, Hôpital Sainte-Marguerite, Aix-Marseille Université, Marseille, France.
| |
Collapse
|
2
|
van Minnen BS, van Tienen TG. The Current State of Meniscus Replacements. Curr Rev Musculoskelet Med 2024; 17:293-302. [PMID: 38744802 PMCID: PMC11219664 DOI: 10.1007/s12178-024-09902-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 04/29/2024] [Indexed: 05/16/2024]
Abstract
PURPOSE OF REVIEW The field of meniscus replacement is changing continuously, with new devices emerging and others disappearing from the market. With the current tendency to preserve the knee joint, meniscus implants may become more relevant than ever. The purpose of this review is to provide an overview of the current state of partial and total meniscus replacements that have been developed beyond the academic phase. The available clinical and pre-clinical data is evaluated, and omissions are identified. RECENT FINDINGS Recent systematic reviews have shown a lack of homogenous clinical data on the CMI and Actifit meniscal scaffolds, especially regarding long-term performance without concomitant surgical interventions. Clinical studies on the medial total meniscus prostheses NUsurface and Artimis are ongoing, with the NUsurface being several years ahead. New techniques for meniscus replacement are rapidly developing, including the Artimis lateral meniscus prosthesis and the MeniscoFix 3D-printed scaffold. All evaluated clinical studies point towards improved clinical outcomes after implantation of partial and total meniscus replacements. Long-term data on survival and performance is of low quality for CMI and Actifit and is unavailable yet for NUsurface and Artimis. It is of major importance that future research focuses on optimizing fixation methods and identifying the optimal treatment strategy for each patient group. New techniques for total and partial replacement of the medial and lateral meniscus will be followed with interest.
Collapse
Affiliation(s)
- B S van Minnen
- Orthopaedic Research Lab, Radboud University Medical Centre, Radboud Institute for Health Sciences, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands.
- ATRO Medical BV, Liessentstraat 9A, 5405 AH, Uden, The Netherlands.
| | - T G van Tienen
- Orthopaedic Research Lab, Radboud University Medical Centre, Radboud Institute for Health Sciences, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands
- ATRO Medical BV, Liessentstraat 9A, 5405 AH, Uden, The Netherlands
| |
Collapse
|
3
|
Bartolo MK, Newman S, Dandridge O, Halewood C, Accardi MA, Dini D, Amis AA. An ovine knee simulator: description and proof of concept. Front Bioeng Biotechnol 2024; 12:1410053. [PMID: 38994124 PMCID: PMC11237960 DOI: 10.3389/fbioe.2024.1410053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2024] [Accepted: 06/05/2024] [Indexed: 07/13/2024] Open
Abstract
Aims The ovine stifle is an established model for evaluation of knee treatments, such as meniscus replacement. This study introduces a novel ovine gait simulator for pre-testing of surgical treatments prior to in vivo animal trials. Furthermore, we describe a pilot study that assessed gait kinematics and contact pressures of native ovine stifle joints and those implanted with a novel fiber-matrix reinforced polyvinyl alcohol-polyethylene glycol (PVA-PEG) hydrogel meniscus to illustrate the efficacy of the simulator. Methods The gait simulator controlled femoral flexion-extension and applied a 980N axial contact force to the distal tibia, whose movement was guided by the natural ligaments. Five right ovine stifle joints were implanted with a PVA-PEG total medial meniscus replacement, fixed to the tibia via transosseous tunnels and interference screws. Six intact and five implanted right ovine stifle joints were tested for 500 k gait cycles at 1.55 Hz. Implanted stifle joint contact pressures and kinematics in the simulator were compared to the intact group. Contact pressures were measured at 55° flexion using pressure sensitive film inserted sub-meniscally. 3D kinematics were measured optically across two 30-s captures. Results Peak contact pressures in intact stifles were 3.6 ± 1.0 MPa and 6.0 ± 2.1 MPa in the medial and lateral condyles (p < 0.05) and did not differ significantly from previous studies (p > 0.4). Medial peak implanted pressures were 4.3 ± 2.2 MPa (p > 0.4 versus intact), while lateral peak pressures (9.4 ± 0.8 MPa) were raised post medial compartment implantation (p < 0.01). The range of motion for intact joints was flexion/extension 37° ± 1°, varus/valgus 1° ± 1°, external/internal rotation 5° ± 3°, lateral/medial translation 2 ± 1 mm, anterior/posterior translation 3 ± 1 mm and distraction/compression 1 ± 1 mm. Ovine joint kinematics in the simulator did not differ significantly from published in vivo data for the intact group, and the intact and implanted groups were comparable (p > 0.01), except for in distraction-compression (p < 0.01). Conclusion These findings show correspondence of the ovine simulator kinematics with in vivo gait parameters. The efficacy of the simulator to evaluate novel treatments was demonstrated by implanting a PVA-PEG hydrogel medial meniscal replacement, which restored the medial peak contact pressures but not lateral. This novel simulator may enable future work on the development of surgical procedures, derisking subsequent work in live animals.
Collapse
Affiliation(s)
- Maria Kristina Bartolo
- Biomechanics Group, Mechanical Engineering Department, Imperial College London, London, United Kingdom
- Orthonika Ltd, London, United Kingdom
| | - Simon Newman
- Department of Surgery and Cancer, Imperial College London School of Medicine, London, United Kingdom
| | - Oliver Dandridge
- Biomechanics Group, Mechanical Engineering Department, Imperial College London, London, United Kingdom
- Orthonika Ltd, London, United Kingdom
| | - Camilla Halewood
- Department of Surgery and Cancer, Imperial College London School of Medicine, London, United Kingdom
| | | | - Daniele Dini
- Biomechanics Group, Mechanical Engineering Department, Imperial College London, London, United Kingdom
| | - Andrew A. Amis
- Biomechanics Group, Mechanical Engineering Department, Imperial College London, London, United Kingdom
| |
Collapse
|
4
|
Li J, Zhang F, Ga X, Gao G, Guo T. Total meniscus replacement with a 3D printing of network hydrogel composite scaffold in a rabbit model. Knee Surg Sports Traumatol Arthrosc 2024; 32:1187-1198. [PMID: 38506124 DOI: 10.1002/ksa.12139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 02/12/2024] [Accepted: 02/22/2024] [Indexed: 03/21/2024]
Abstract
PURPOSE The aim of this study was to evaluate the role of a novel total meniscal implant in promoting meniscal regeneration and protecting articular cartilage in a rabbit model for 3 and 6 months. METHODS Thirty-six New Zealand rabbits were selected and divided into poly(ɛ-caprolactone) (PG-Pg) scaffold group, meniscectomy group and sham group. In this study, it was investigated whether PG-Pg scaffold can prevent articular cartilage degeneration and promote tissue degeneration, and its mechanical properties at 3 and 6 months after surgery were also explored. RESULT The degree of articular cartilage degeneration was significantly lower in the PG-Pg scaffold group than in the meniscectomy group. The number of chondrocytes increased in the PG-Pg scaffold at 3 and 6 months, while a gradual increase in the mechanical properties of the PG-Pg stent was observed from 6 months. CONCLUSION The PG-Pg scaffold slows down the degeneration of articular cartilage, promotes tissue regeneration and improves biomechanical properties after meniscectomy. This novel meniscus scaffold holds promise for enhancing surgical strategies and delivering superior long-term results for individuals with severe meniscus tears. LEVEL OF EVIDENCE NA.
Collapse
Affiliation(s)
- Jiaran Li
- Guizhou Provincial People's Hospital, Guiyang, China
- The Third Affiliated Hospital of Xinxiang Medical College, Xinxiang, China
| | | | - Xisijia Ga
- Guizhou Provincial People's Hospital, Guiyang, China
| | - Gan Gao
- Guizhou Provincial People's Hospital, Guiyang, China
| | - Tao Guo
- Guizhou Provincial People's Hospital, Guiyang, China
| |
Collapse
|
5
|
González-Duque MI, Flórez AM, Torres MA, Fontanilla MR. Composite Zonal Scaffolds of Collagen I/II for Meniscus Regeneration. ACS Biomater Sci Eng 2024; 10:2426-2441. [PMID: 38549452 DOI: 10.1021/acsbiomaterials.3c01737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/09/2024]
Abstract
The meniscus is divided into three zones according to its vascularity: an external vascularized red-red zone mainly comprising collagen I, a red-white interphase zone mainly comprising collagens I and II, and an internal white-white zone rich in collagen II. Known scaffolds used to treat meniscal injuries do not reflect the chemical composition of the vascular areas of the meniscus. Therefore, in this study, four composite zonal scaffolds (named A, B, C, and D) were developed and characterized; the developed scaffolds exhibited the main chemical components of the external (collagen I), interphase (collagens I/II), and internal (collagen II) zones of the meniscus. Noncomposite scaffolds were also produced (named E), which had the same shape as the composite scaffolds but were entirely made of collagen I. The composite zonal scaffolds were prepared using different concentrations of collagen I and the same concentration of collagen II and were either cross-linked with genipin or not cross-linked. Porous, biodegradable, and hydrophilic scaffolds with an expected chemical composition were obtained. Their pore size was smaller than the size reported for the meniscus substitutes; however, all scaffolds allowed the adhesion and proliferation of human adipose-derived stem cells (hADSCs) and were not cytotoxic. Data from enzymatic degradation and hADSC proliferation assays were considered for choosing the cross-linked composite scaffolds along with the collagen I scaffold and to test if composite zonal scaffolds seeded with hADSC and cultured with differentiation medium produced fibrocartilage-like tissue different from that formed in noncomposite scaffolds. After 21 days of culture, hADSCs seeded on composite scaffolds afforded an extracellular matrix with aggrecan, whereas hADSCs seeded on noncomposite collagen I scaffolds formed a matrix-like fibrocartilage without aggrecan.
Collapse
Affiliation(s)
- Martha Isabel González-Duque
- Tissue Engineering Group, Departmento de Farmacia, Facultad de Ciencias, Universidad Nacional de Colombia, Av. Carrera 30 # 45-10, Bogotá 111321, D.C., Colombia
| | - Adriana Matilde Flórez
- Tissue Engineering Group, Departmento de Farmacia, Facultad de Ciencias, Universidad Nacional de Colombia, Av. Carrera 30 # 45-10, Bogotá 111321, D.C., Colombia
| | - María Alejandra Torres
- Tissue Engineering Group, Departmento de Farmacia, Facultad de Ciencias, Universidad Nacional de Colombia, Av. Carrera 30 # 45-10, Bogotá 111321, D.C., Colombia
| | - Marta Raquel Fontanilla
- Tissue Engineering Group, Departmento de Farmacia, Facultad de Ciencias, Universidad Nacional de Colombia, Av. Carrera 30 # 45-10, Bogotá 111321, D.C., Colombia
| |
Collapse
|
6
|
Chen R, Zhao H, Ai L, Zhang J, Jiang D. Inhibiting T-Cell-Mediated Rejection of the Porcine Meniscus Through Freeze-Thawing and Downregulating Porcine Xenoreactive Antigen Genes. Cell Transplant 2024; 33:9636897241273689. [PMID: 39180383 PMCID: PMC11344903 DOI: 10.1177/09636897241273689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Revised: 06/25/2024] [Accepted: 07/08/2024] [Indexed: 08/26/2024] Open
Abstract
Immune rejection presents a significant challenge in xenogenic meniscal transplantation. Pigs are widely regarded as an advantageous tissue source for such transplants, with porcine GGTA1, CMAH, and B4GALNT2 being among the most common xenoreactive antigen (Ag) genes. While some studies have suggested that allogeneic meniscus (AM) transplants may exhibit immunoprivileged properties, our study observed slight immunological rejection has been observed following contact between human meniscal cells (HMCs) and human peripheral blood mononuclear cells (PBMCs). Given the limited systematic research on immune responses following xenograft meniscus transplantation, we established porcine meniscus transplantation (PMT) models to comprehensively assess the immunogenicity of porcine meniscus (PM) from both innate and adaptive immune perspectives. Our investigations confirmed that PMT beneath the epidermis led to innate cell infiltration into the xenografts and T-cell activation in local lymph nodes. T-cell activation upregulated the interleukin (IL)-17 signaling pathway, disrupting collagen organization and metabolic processes, thereby hindering PM regeneration. Using freeze-thaw treatment on PM alleviated T-cell activation post-transplantation by eliminating xenogenic DNA. In vitro findings demonstrated that gene editing in porcine meniscal cells (PMCs) suppressed human T-cell activation by downregulating the expression of xenoreactive Ag genes. These results suggest that GGTA1/CMAH/B4GALNT2 knockout (KO) pigs hold significant promise for advancing the field of meniscal transplantation.
Collapse
Affiliation(s)
- Rao Chen
- Department of Sports Medicine, Institute of Sports Medicine, Peking University Third Hospital, Peking University, Beijing, P.R. China
- Beijing Key Laboratory of Sports Injuries, Beijing, P.R. China
- Engineering Research Center of Sports Trauma Treatment Technology and Devices, Ministry of Education, Beijing, P.R. China
| | - Hailong Zhao
- School of Basic Medical Science, Peking University, Beijing, P.R. China
- Peking University International Cancer Institute, Beijing, P.R. China
| | - Liya Ai
- Department of Sports Medicine, Institute of Sports Medicine, Peking University Third Hospital, Peking University, Beijing, P.R. China
- Beijing Key Laboratory of Sports Injuries, Beijing, P.R. China
- Engineering Research Center of Sports Trauma Treatment Technology and Devices, Ministry of Education, Beijing, P.R. China
| | - Jiying Zhang
- Department of Sports Medicine, Institute of Sports Medicine, Peking University Third Hospital, Peking University, Beijing, P.R. China
- Beijing Key Laboratory of Sports Injuries, Beijing, P.R. China
- Engineering Research Center of Sports Trauma Treatment Technology and Devices, Ministry of Education, Beijing, P.R. China
| | - Dong Jiang
- Department of Sports Medicine, Institute of Sports Medicine, Peking University Third Hospital, Peking University, Beijing, P.R. China
- Beijing Key Laboratory of Sports Injuries, Beijing, P.R. China
- Engineering Research Center of Sports Trauma Treatment Technology and Devices, Ministry of Education, Beijing, P.R. China
| |
Collapse
|
7
|
Dai P, Zou T, Zhao W, Lv Y, Gao D, Ruan C, Zhang X, Zhang X, Zhang Y. Short-term transplantation effect of a tissue-engineered meniscus constructed using drilled allogeneic acellular meniscus and BMSCs. Front Vet Sci 2023; 10:1266018. [PMID: 38046571 PMCID: PMC10693448 DOI: 10.3389/fvets.2023.1266018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Accepted: 10/30/2023] [Indexed: 12/05/2023] Open
Abstract
During the construction of tissue-engineered meniscus, the low porosity of extracellular matrix restricts the flow of nutrient solution and the migration and proliferation of cells, thus affecting the tissue remodeling after transplantation. In this study, the canine allogeneic meniscus was drilled first and then decellularized. The drilled tissue-engineered menisci (Drilled Allogeneic Acellular Meniscus + Bone Marrow Mesenchymal Stem Cells, BMSCs) were transplanted into the knee joints of model dogs. On the basis of ensuring the mechanical properties, the number of the porosity and the cells implanted in allogeneic acellular meniscus was significantly increased. The expression levels of glycosaminoglycans and type II collagen in the drilled tissue-engineered meniscus were also improved. It was determined that the animals in the experimental group recovered well-compared with those in the control group. The graft surface was covered with new cartilage, the retraction degree was small, and the tissue remodeling was good. The surface wear of the femoral condyle and tibial plateau cartilage was light. The results of this study showed that increasing the porosity of allogeneic meniscus by drilling could not only maintain the mechanical properties of the meniscus and increase the number of implanted cells but also promote cell proliferation and differentiation. After transplantation, the drilled tissue-engineered meniscus provided a good remodeling effect in vivo and played a positive role in repairing meniscal injury, protecting articular cartilage and restoring knee joint function.
Collapse
Affiliation(s)
- Pengxiu Dai
- Shaanxi Branch of National Stem Cell Engineering and Technology Centre, College of Veterinary Medicine, Northwest A&F University, Xianyang, Shaanxi, China
| | - Tong Zou
- Shaanxi Branch of National Stem Cell Engineering and Technology Centre, College of Veterinary Medicine, Northwest A&F University, Xianyang, Shaanxi, China
| | - Wen Zhao
- Shaanxi Branch of National Stem Cell Engineering and Technology Centre, College of Veterinary Medicine, Northwest A&F University, Xianyang, Shaanxi, China
| | - Yangou Lv
- Shaanxi Branch of National Stem Cell Engineering and Technology Centre, College of Veterinary Medicine, Northwest A&F University, Xianyang, Shaanxi, China
| | - Dengke Gao
- Shaanxi Branch of National Stem Cell Engineering and Technology Centre, College of Veterinary Medicine, Northwest A&F University, Xianyang, Shaanxi, China
| | - Chenmei Ruan
- Shaanxi Branch of National Stem Cell Engineering and Technology Centre, College of Veterinary Medicine, Northwest A&F University, Xianyang, Shaanxi, China
| | - Xia Zhang
- Shaanxi Branch of National Stem Cell Engineering and Technology Centre, College of Veterinary Medicine, Northwest A&F University, Xianyang, Shaanxi, China
| | - Xinke Zhang
- Shaanxi Branch of National Stem Cell Engineering and Technology Centre, College of Veterinary Medicine, Northwest A&F University, Xianyang, Shaanxi, China
| | - Yihua Zhang
- Shaanxi Branch of National Stem Cell Engineering and Technology Centre, College of Veterinary Medicine, Northwest A&F University, Xianyang, Shaanxi, China
- Baiopai (Tianjin) Biotechnology Co., LTD, Tianjin, China
| |
Collapse
|
8
|
Dabaghi M, Eras V, Kaltenhaeuser D, Ahmed N, Wildemann B. Allografts for partial meniscus repair: an in vitro and ex vivo meniscus culture study. Front Bioeng Biotechnol 2023; 11:1268176. [PMID: 37901839 PMCID: PMC10603185 DOI: 10.3389/fbioe.2023.1268176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Accepted: 09/11/2023] [Indexed: 10/31/2023] Open
Abstract
The purpose of this study was to evaluate the treatment potential of a human-derived demineralized scaffold, Spongioflex® (SPX), in partial meniscal lesions by employing in vitro models. In the first step, the differentiation potential of human meniscal cells (MCs) was investigated. In the next step, the ability of SPX to accommodate and support the adherence and/or growth of MCs while maintaining their fibroblastic/chondrocytic properties was studied. Control scaffolds, including bovine collagen meniscus implant (CMI) and human meniscus allograft (M-Allo), were used for comparison purposes. In addition, the migration tendency of MCs from fresh donor meniscal tissue into SPX was investigated in an ex vivo model. The results showed that MCs cultured in osteogenic medium did not differentiate into osteogenic cells or form significant calcium phosphate deposits, although AP activity was relatively increased in these cells. Culturing cells on the scaffolds revealed increased viability on SPX compared to the other scaffold materials. Collagen I synthesis, assessed by ELISA, was similar in cells cultured in 2D and on SPX. MCs on micro-porous SPX (weight >0.5 g/cm3) exhibited increased osteogenic differentiation indicated by upregulated expression of ALP and RUNX2, while also showing upregulated expression of the chondrogen-specific SOX9 and ACAN genes. Ingrowth of cells on SPX was observed after 28 days of cultivation. Overall, the results suggest that SPX could be a promising biocompatible scaffold for meniscal regeneration.
Collapse
Affiliation(s)
- Mohammad Dabaghi
- Experimental Trauma Surgery, Department of Trauma, Hand and Reconstructive Surgery, Jena University Hospital, Friedrich Schiller University Jena, Jena, Germany
| | - Volker Eras
- German Institute for Cell and Tissue Replacement (DIZG, gemeinnützige GmbH), Berlin, Germany
| | - Daniel Kaltenhaeuser
- German Institute for Cell and Tissue Replacement (DIZG, gemeinnützige GmbH), Berlin, Germany
| | - Norus Ahmed
- German Institute for Cell and Tissue Replacement (DIZG, gemeinnützige GmbH), Berlin, Germany
| | - Britt Wildemann
- Experimental Trauma Surgery, Department of Trauma, Hand and Reconstructive Surgery, Jena University Hospital, Friedrich Schiller University Jena, Jena, Germany
| |
Collapse
|
9
|
Kaarre J, Herman ZJ, Zsidai B, Grassi A, Zaffagnini S, Samuelsson K, Musahl V. Meniscus allograft transplantation for biologic knee preservation: gold standard or dilemma? Knee Surg Sports Traumatol Arthrosc 2023; 31:3579-3581. [PMID: 36205759 DOI: 10.1007/s00167-022-07187-w] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Accepted: 09/27/2022] [Indexed: 02/14/2023]
Affiliation(s)
- Janina Kaarre
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
- Sahlgrenska Sports Medicine Center (SSMC), Gothenburg, Sweden.
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, University of Pittsburg, Pittsburgh, USA.
- Department of Orthopaedics, Sahlgrenska University Hospital, Mölndal, Sweden.
| | - Zachary J Herman
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, University of Pittsburg, Pittsburgh, USA
| | - Bálint Zsidai
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Sahlgrenska Sports Medicine Center (SSMC), Gothenburg, Sweden
| | - Alberto Grassi
- IIa Clinica Ortopedica e Traumatologica, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Stefano Zaffagnini
- IIa Clinica Ortopedica e Traumatologica, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Kristian Samuelsson
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Sahlgrenska Sports Medicine Center (SSMC), Gothenburg, Sweden
- Department of Orthopaedics, Sahlgrenska University Hospital, Mölndal, Sweden
| | - Volker Musahl
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, University of Pittsburg, Pittsburgh, USA
| |
Collapse
|
10
|
Rotini M, Papalia G, Setaro N, Luciani P, Marinelli M, Specchia N, Gigante A. Arthroscopic surgery or exercise therapy for degenerative meniscal lesions: a systematic review of systematic reviews. Musculoskelet Surg 2023; 107:127-141. [PMID: 36057031 PMCID: PMC10192166 DOI: 10.1007/s12306-022-00760-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Accepted: 07/30/2022] [Indexed: 12/14/2022]
Abstract
BACKGROUND Arthroscopic partial meniscectomy (APM) is widely applied for the treatment of degenerative meniscal lesions in middle-aged patients; however, such injury is often associated with mild or moderate osteoarthritis and has been reported by MRI in asymptomatic knees. Previous studies suggested, in most patients, a lack of benefit of surgical approach over conservative treatment, yet many controversies remain in clinical practice. Our aims were to assess the functional and pain scores between exercise therapy and arthroscopic surgery for degenerative meniscal lesions and to evaluate the methodological quality of the most recent systematic reviews (SRs). METHODS Two authors independently searched PubMed and Google Scholar for SRs comparing the outcome (in knee pain and functionality) of arthroscopic treatment and exercise therapy or placebo for degenerative meniscal lesions. The timeframe set was from 2009 to 2019 included. RESULTS A total of 13 SRs were selected. Two reviewers independently assessed the methodological quality of each paper using the AMSTAR 2 tool: seven scored as "moderate," four obtained a "low" grade while the remaining two were evaluated as "critically low." SRs agreed that in middle-aged patients with degenerative meniscal lesions arthroscopic surgery appears to grant no long-term improvement in pain and function over exercise therapy or placebo. CONCLUSIONS Conservative treatment based on physical therapy should be the first-line management. However, most SRs revealed subgroups of patients that fail to improve after conservative treatment and find relief when undergoing surgery. In the future, randomized controlled trials, evidence should be looked for that APM can be successful in case of the unsatisfactory results after physical therapy.
Collapse
Affiliation(s)
- M Rotini
- Department of Clinical and Molecular Science, School of Medicine, Università Politecnica Delle Marche, Via Tronto, 10/A, 60126, Ancona, Italy
| | - G Papalia
- Department of Clinical and Molecular Science, School of Medicine, Università Politecnica Delle Marche, Via Tronto, 10/A, 60126, Ancona, Italy
| | - N Setaro
- Department of Clinical and Molecular Science, School of Medicine, Università Politecnica Delle Marche, Via Tronto, 10/A, 60126, Ancona, Italy
| | - P Luciani
- Department of Clinical and Molecular Science, School of Medicine, Università Politecnica Delle Marche, Via Tronto, 10/A, 60126, Ancona, Italy
| | - M Marinelli
- Clinic of Adult and Paediatric Orthopaedic, Azienda Ospedaliero-Universitaria, Ospedali Riuniti Di Ancona, Via Tronto 10/ 60126, Ancona, Italy
| | - N Specchia
- Clinic of Adult and Paediatric Orthopaedic, Azienda Ospedaliero-Universitaria, Ospedali Riuniti Di Ancona, Via Tronto 10/ 60126, Ancona, Italy
| | - A Gigante
- Department of Clinical and Molecular Science, School of Medicine, Università Politecnica Delle Marche, Via Tronto, 10/A, 60126, Ancona, Italy.
| |
Collapse
|
11
|
High-grade preoperative osteoarthritis of the index compartment is a major predictor of meniscal allograft failure. Arch Orthop Trauma Surg 2023; 143:399-407. [PMID: 34988673 DOI: 10.1007/s00402-021-04306-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Accepted: 12/07/2021] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Preoperatively available predictors of meniscal allograft failure would help in patient counseling and surgical indication for meniscal allograft transplantation (MAT). It was hypothesized that young patient age, high posterior tibial slope (PTS), and high-grade osteoarthritis (OA) are predictors of meniscal allograft failure. MATERIALS AND METHODS Patients undergoing MAT with a minimum follow-up of 2 years were included in this retrospective study. Demographic and surgical data, and causes of meniscal allograft failure were collected. PTS and degree of OA (low-grade: Kellgren-Lawrence 0, 1, and 2; high-grade: Kellgren-Lawrence 3 and 4) of the index and opposite tibiofemoral compartments were determined on preoperative radiographs. RESULTS This study included 77 patients with a mean age of 25.7 ± 10.1 years at the time of MAT. After a mean follow-up of 7.6 ± 5.6 years, meniscal allograft failure was observed in 26 patients (34%). The median time from MAT to meniscal allograft failure was 1.3 years (inter-quartile range, 2.5 years). Meniscal allograft tears (88%) were the primary cause of graft failure, followed by high-grade OA (12%). Patients experiencing meniscal allograft failure were an average of 2.7 years (95% CI [2.2, 7.5], p = 0.202) older at the time of MAT than patients without failure. PTS was not found to be a predictor of meniscal allograft failure (odds ratio, 0.884 (95% CI [0.727, 1.073], p = 0.212)). Patients with high-grade preoperative OA of the index compartment had 28 times higher odds of experiencing meniscal allograft failure than patients with low-grade preoperative OA (p = 0.008). CONCLUSIONS High-grade preoperative OA of the index compartment was found to be a significant and clinically relevant predictor of meniscal allograft failure. Surgeons should be aware of the impact of OA on meniscal allograft survival, which needs to be considered in patient counseling and surgical indication for MAT in patients.
Collapse
|
12
|
Kohli S, Schwenck J, Barlow I. Failure rates and clinical outcomes of synthetic meniscal implants following partial meniscectomy: a systematic review. Knee Surg Relat Res 2022; 34:27. [PMID: 35692048 PMCID: PMC9190156 DOI: 10.1186/s43019-022-00155-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Accepted: 05/05/2022] [Indexed: 12/13/2022] Open
Abstract
Background Meniscal injury is one of the most common indications for knee surgery. The advent of meniscal repair techniques has facilitated meniscal preservation in suitable cases. Meniscal substitution with scaffolds may be advantageous following partial meniscal resection. There are three main scaffolds in current clinical use; Collagen Meniscal Implant (CMI Stryker Corporation, Kalamazoo, MI, USA), Actifit (Actifit, Orteq Ltd, London, UK) and NUsurface (Active Implants, LLC). The purpose of this systematic review was to compare clinical outcomes and failure rates of patients who have had implantation with these meniscal scaffolds. Methods MEDLINE and EMBASE databases were searched for studies that included patients who had surgical implantation with Actifit or CMI. Eligibility criteria included papers that described both clinical outcomes and failure rates of these implants, a mean follow up of 5 years and studies published in English. A Google search was also performed to identify any grey literature. Results Five Level IV studies were found for Actifit. One Level II, one Level III and four Level IV studies were found for the CMI implant. One Level II study was identified for the NUsurface scaffold with a follow-up 12 months and was included for completeness. Overall, 262 patients were treated with Actifit, 109 with CMI and 65 with NUsurface. Failure rates for Actifit were 18% (range 6.3–31.8%) with a mean follow up of 66.8 months, and for CMI 6.5% (range 0–11.8%) with a mean follow up of 97.1 months. The NUsurface failure rate was 16.9% at 12 months. Clinical outcomes such as VAS, Tegner and Lysholm scores improved significantly post-operatively. However, there was a high volume of concurrent procedures, such as anterior cruciate ligament reconstructions and high tibial osteotomies in each study group; 118 (45%) for Actifit and 53 (45%) for CMI. Conclusion The evidence for meniscal scaffold use is insufficient to suggest that they could potentially improve clinical outcomes in patients post-meniscal resection. This is largely due to the high proportion of concurrent procedures performed at index procedure for both CMI and Actifit. On the basis of current evidence, the use of meniscal scaffolds as a sole treatment for partial meniscal defects cannot be recommended, owing to the relatively high failure rate and paucity of clinical data.
Collapse
|
13
|
Extrusion, meniscal signal change, loss of shape, synovitis and bone marrow oedema are reliable scoring parameters to assess MRI appearance post meniscal transplant. Knee Surg Sports Traumatol Arthrosc 2022; 30:1527-1534. [PMID: 34459933 DOI: 10.1007/s00167-021-06720-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Accepted: 08/24/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE Meniscal allograft transplantation (MAT) has shown good promise in restoring normal knee joint biomechanics in a meniscal deficient patient. However, MRI appearance of the meniscal allograft is often questioned and raises concerns of its viability and function. This paper aims to introduce and validate a new scoring system for MAT MRI appearance at 12 months [MRI appearance in Meniscal Transplant Score (MIMS)], using key changes such as extrusion, meniscal signal change, loss of shape, synovitis and bone marrow oedema. METHODS A retrospective analysis of 10 patients from a single surgeon series was conducted. All MAT were performed with soft tissue fixation technique. MRI was performed at 12 months post-transplant with two independent consultant musculoskeletal radiologists and one experienced meniscal transplant surgeon scoring the images obtained. Interobserver agreement and intraclass correlation were measured. RESULTS Interobserver agreement between examiners on individual features of the MIMS was superior for tibial bone oedema, substantial for meniscal extrusion and femoral bone oedema, moderate for meniscal shape and synovitis, and fair for meniscal signal changes. Absolute agreement between raters found good reliability (ICC = 0.774; 95% 0.359, 0.960) for single measures and excellent reliability (ICC = 0.911; 95% 0.627, 0.986) for average measures. CONCLUSION MIMS is a reliable method of evaluating the meniscal allograft transplant 12 months post-transplant. Further research with larger MAT cohort groups and patient reported outcome measures may be helpful to correlate its clinical significance and guide further management. LEVEL OF EVIDENCE Level III.
Collapse
|
14
|
Dorthé EW, Williams AB, Grogan SP, D’Lima DD. Pneumatospinning Biomimetic Scaffolds for Meniscus Tissue Engineering. Front Bioeng Biotechnol 2022; 10:810705. [PMID: 35186903 PMCID: PMC8847752 DOI: 10.3389/fbioe.2022.810705] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2021] [Accepted: 01/10/2022] [Indexed: 02/06/2023] Open
Abstract
Nanofibrous scaffolds fabricated via electrospinning have been proposed for meniscus tissue regeneration. However, the electrospinning process is slow, and can only generate scaffolds of limited thickness with densely packed fibers, which limits cell distribution within the scaffold. In this study, we explored whether pneumatospinning could produce thicker collagen type I fibrous scaffolds with higher porosity, that can support cell infiltration and neo-fibrocartilage tissue formation for meniscus tissue engineering. We pneumatospun scaffolds with solutions of collagen type I with thicknesses of approximately 1 mm in 2 h. Scanning electron microscopy revealed a mix of fiber sizes with diameters ranging from 1 to 30 µm. The collagen scaffold porosity was approximately 48% with pores ranging from 7.4 to 100.7 µm. The elastic modulus of glutaraldehyde crosslinked collagen scaffolds was approximately 45 MPa, when dry, which reduced after hydration to 0.1 MPa. Mesenchymal stem cells obtained from the infrapatellar fat pad were seeded in the scaffold with high viability (>70%). Scaffolds seeded with adipose-derived stem cells and cultured for 3 weeks exhibited a fibrocartilage meniscus-like phenotype (expressing COL1A1, COL2A1 and COMP). Ex vivo implantation in healthy bovine and arthritic human meniscal explants resulted in the development of fibrocartilage-like neotissues that integrated with the host tissue with deposition of glycosaminoglycans and collagens type I and II. Our proof-of-concept study indicates that pneumatospinning is a promising approach to produce thicker biomimetic scaffolds more efficiently that electrospinning, and with a porosity that supports cell growth and neo-tissue formation using a clinically relevant cell source.
Collapse
Affiliation(s)
- Erik W. Dorthé
- Department of Orthopaedics, Shiley Center for Orthopaedic Research and Education, Scripps Health, San Diego, CA, United States
| | | | - Shawn P. Grogan
- Department of Orthopaedics, Shiley Center for Orthopaedic Research and Education, Scripps Health, San Diego, CA, United States
| | - Darryl D. D’Lima
- Department of Orthopaedics, Shiley Center for Orthopaedic Research and Education, Scripps Health, San Diego, CA, United States
| |
Collapse
|
15
|
Stocco E, Porzionato A, De Rose E, Barbon S, Caro RD, Macchi V. Meniscus regeneration by 3D printing technologies: Current advances and future perspectives. J Tissue Eng 2022; 13:20417314211065860. [PMID: 35096363 PMCID: PMC8793124 DOI: 10.1177/20417314211065860] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Accepted: 11/24/2021] [Indexed: 01/10/2023] Open
Abstract
Meniscal tears are a frequent orthopedic injury commonly managed by conservative
strategies to avoid osteoarthritis development descending from altered
biomechanics. Among cutting-edge approaches in tissue engineering, 3D printing
technologies are extremely promising guaranteeing for complex biomimetic
architectures mimicking native tissues. Considering the anisotropic
characteristics of the menisci, and the ability of printing over structural
control, it descends the intriguing potential of such vanguard techniques to
meet individual joints’ requirements within personalized medicine. This
literature review provides a state-of-the-art on 3D printing for meniscus
reconstruction. Experiences in printing materials/technologies, scaffold types,
augmentation strategies, cellular conditioning have been compared/discussed;
outcomes of pre-clinical studies allowed for further considerations. To date,
translation to clinic of 3D printed meniscal devices is still a challenge:
meniscus reconstruction is once again clear expression of how the integration of
different expertise (e.g., anatomy, engineering, biomaterials science, cell
biology, and medicine) is required to successfully address native tissues
complexities.
Collapse
Affiliation(s)
- Elena Stocco
- Department of Neuroscience, Section of Human Anatomy, University of Padova, Padova, Italy
- L.i.f.e.L.a.b. Program, Consorzio per la Ricerca Sanitaria, Padova, Italy
| | - Andrea Porzionato
- Department of Neuroscience, Section of Human Anatomy, University of Padova, Padova, Italy
- L.i.f.e.L.a.b. Program, Consorzio per la Ricerca Sanitaria, Padova, Italy
| | - Enrico De Rose
- Department of Neuroscience, Section of Human Anatomy, University of Padova, Padova, Italy
| | - Silvia Barbon
- Department of Neuroscience, Section of Human Anatomy, University of Padova, Padova, Italy
- L.i.f.e.L.a.b. Program, Consorzio per la Ricerca Sanitaria, Padova, Italy
| | - Raffaele De Caro
- Department of Neuroscience, Section of Human Anatomy, University of Padova, Padova, Italy
- L.i.f.e.L.a.b. Program, Consorzio per la Ricerca Sanitaria, Padova, Italy
| | - Veronica Macchi
- Department of Neuroscience, Section of Human Anatomy, University of Padova, Padova, Italy
- L.i.f.e.L.a.b. Program, Consorzio per la Ricerca Sanitaria, Padova, Italy
| |
Collapse
|
16
|
Strength of interference screw fixation of meniscus prosthesis matches native meniscus attachments. Knee Surg Sports Traumatol Arthrosc 2022; 30:2259-2266. [PMID: 34665300 PMCID: PMC9206603 DOI: 10.1007/s00167-021-06772-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/07/2021] [Accepted: 10/07/2021] [Indexed: 12/18/2022]
Abstract
PURPOSE Meniscal surgery is one of the most common orthopaedic surgical interventions. Total meniscus replacements have been proposed as a solution for patients with irreparable meniscal injuries. Reliable fixation is crucial for the success and functionality of such implants. The aim of this study was to characterise an interference screw fixation system developed for a novel fibre-matrix-reinforced synthetic total meniscus replacement in an ovine cadaveric model. METHODS Textile straps were tested in tension to failure (n = 15) and in cyclic tension (70-220 N) for 1000 cycles (n = 5). The textile strap-interference screw fixation system was tested in 4.5 mm-diameter single anterior and double posterior tunnels in North of England Mule ovine tibias aged > 2 years using titanium alloy (Ti6Al4Va) and polyether-ether-ketone (PEEK) screws (n ≥ 5). Straps were preconditioned, dynamically loaded for 1000 cycles in tension (70-220 N), the fixation slippage under cyclic loading was measured, and then pulled to failure. RESULTS Strap stiffness was at least 12 times that recorded for human meniscal roots. Strap creep strain at the maximum load (220 N) was 0.005 following 1000 cycles. For all tunnels, pull-out failure resulted from textile strap slippage or bone fracture rather than strap rupture, which demonstrated that the textile strap was comparatively stronger than the interference screw fixation system. Pull-out load (anterior 544 ± 119 N; posterior 889 ± 157 N) was comparable to human meniscal root strength. Fixation slippage was within the acceptable range for anterior cruciate ligament graft reconstruction (anterior 1.9 ± 0.7 mm; posterior 1.9 ± 0.5 mm). CONCLUSION These findings show that the textile attachment-interference screw fixation system provides reliable fixation for a novel ovine meniscus implant, supporting progression to in vivo testing. This research provides a baseline for future development of novel human meniscus replacements, in relation to attachment design and fixation methods. The data suggest that surgical techniques familiar from ligament reconstruction may be used for the fixation of clinical meniscal prostheses.
Collapse
|
17
|
Germany has a high demand in meniscal allograft transplantation but is subject to health economic and legal challenges: a survey of the German Knee Society. Knee Surg Sports Traumatol Arthrosc 2022; 30:2352-2357. [PMID: 35099598 PMCID: PMC9206617 DOI: 10.1007/s00167-022-06889-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Accepted: 01/13/2022] [Indexed: 11/06/2022]
Abstract
PURPOSE To determine the current status and demand of meniscal allograft transplantation (MAT) in Germany among members of the German Knee Society (= Deutsche Kniegesellschaft; DKG). METHODS An online survey was conducted between May 2021 and June 2021 and sent to all members of the DKG. The survey questionnaire consisted of 19 questions to determine the demand and technical aspects of MAT among the participants and to identify areas of improvement in MAT in Germany. RESULTS Overall, 152 participants, 136 (89.5%) from Germany, 8 (5.3%) from Switzerland, 6 (4.0%) from Austria, and 2 (1.3%) from other countries completed the online survey, with the majority working in non-academic institutions. According to the regulations of the DKG, 87 (57.2%) participants were board certified as specialized knee surgeons and 97 (63.8%) worked primarily in the field of orthopedic sports medicine. MAT was considered clinically necessary in Germany by 139 (91.5%) participants. Patient age (83.6%), post-meniscectomy syndrome in isolated lateral (79.6%) and medial (71.7%) meniscus deficiency, and functional and athletic demands (43.4%) were the most important determinants to consider MAT in patients. Participants reported that reimbursement (82.9%), jurisdiction over the use of donor grafts (77.6%), and the availability of meniscal allografts (76.3%) are the main challenges in performing MAT in Germany. The most frequently used meniscal allograft types by 54 (35.5%) participants who had already performed MAT were fresh-frozen grafts (56.6%), peracetic acid-ethanol sterilized grafts (35.9%), and cryopreserved grafts (7.6%). Participants reported to perform suture-only fixation more often than bone block fixation for both medial (73.6% vs. 22.6%) and lateral (69.8% vs. 24.5%) MAT. CONCLUSION More than 90% of the responding members of the DKG indicated that MAT is a clinically important and valuable procedure in Germany. Reimbursement, jurisdiction over the use of donor grafts, and the availability of meniscal allografts should be improved. This survey is intended to support future efforts to facilitate MAT in daily clinical practice in Germany. LEVEL OF EVIDENCE Level V.
Collapse
|
18
|
Vasiliadis AV, Koukoulias N, Katakalos K. Three-Dimensional-Printed Scaffolds for Meniscus Tissue Engineering: Opportunity for the Future in the Orthopaedic World. J Funct Biomater 2021; 12:jfb12040069. [PMID: 34940548 PMCID: PMC8708065 DOI: 10.3390/jfb12040069] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Revised: 11/29/2021] [Accepted: 12/01/2021] [Indexed: 12/17/2022] Open
Abstract
The meniscus is a critical component of a healthy knee joint. It is a complex and vital fibrocartilaginous tissue that maintains appropriate biomechanics. Injuries of the meniscus, particularly in the inner region, rarely heal and usually progress into structural breakdown, followed by meniscus deterioration and initiation of osteoarthritis. Conventional therapies range from conservative treatment, to partial meniscectomy and even meniscus transplantation. All the above have high long-term failure rates, with recurrence of symptoms. This communication presents a brief account of in vitro and in vivo studies and describes recent developments in the field of 3D-printed scaffolds for meniscus tissue engineering. Current research in meniscal tissue engineering tries to combine polymeric biomaterials, cell-based therapy, growth factors, and 3D-printed scaffolds to promote the healing of meniscal defects. Today, 3D-printing technology represents a big opportunity in the orthopaedic world to create more specific implants, enabling the rapid production of meniscal scaffolds and changing the way that orthopaedic surgeons plan procedures. In the future, 3D-printed meniscal scaffolds are likely to be available and will also be suitable substitutes in clinical applications, in an attempt to imitate the complexity of the native meniscus.
Collapse
Affiliation(s)
- Angelo V. Vasiliadis
- 2nd Orthopaedic Department, General Hospital of Thessaloniki “Papageorgiou”, 56403 Thessaloniki, Greece
- School of Medicine, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
- Correspondence: ; Tel.: +30-6948402828
| | - Nikolaos Koukoulias
- Orthopaedic Department, Sports Injuries Unit, Saint Luke’s Hospital, 55236 Thessaloniki, Greece;
| | - Konstantinos Katakalos
- Laboratory for Strength of Materials and Structures, Department of Civil Engineering, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece;
| |
Collapse
|
19
|
Berni M, Marchiori G, Cassiolas G, Grassi A, Zaffagnini S, Fini M, Lopomo NF, Maglio M. Anisotropy and inhomogeneity of permeability and fibrous network response in the pars intermedia of the human lateral meniscus. Acta Biomater 2021; 135:393-402. [PMID: 34411754 DOI: 10.1016/j.actbio.2021.08.020] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Revised: 08/10/2021] [Accepted: 08/12/2021] [Indexed: 02/07/2023]
Abstract
Within the human tibiofemoral joint, meniscus plays a key role due to its peculiar time-dependent mechanical characteristics, inhomogeneous structure and compositional features. To better understand the pathophysiological mechanisms underlying this essential component, it is mandatory to analyze in depth the relationship between its structure and the function it performs in the joint. Accordingly, the aim of this study was to evaluate the behavior of both solid and fluid phases of human meniscus in response to compressive loads, by integrating mechanical assessment and histological analysis. Cubic specimens were harvested from seven knee lateral menisci, specifically from anterior horn, pars intermedia and posterior horn; unconfined compressive tests were then performed according to three main loading directions (i.e., radial, circumferential and vertical). Fibril modulus, matrix modulus and hydraulic permeability of the tissue were thence estimated through a fibril-network-reinforced biphasic model. Tissue porosity and collagen fibers arrangement were assessed through histology for each region and related to the loading directions adopted during mechanical tests. Regional and strain-dependent constitutive parameters were finally proposed for the human lateral meniscus, suggesting an isotropic behavior of both the horns, and a transversely isotropic response of the pars intermedia. Furthermore, the histological findings supported the evidences highlighted by the compressive tests. Indeed, this study provided novel insights concerning the functional behavior of human menisci by integrating mechanical and histological characterizations and thus highlighting the key role of this component in knee contact mechanics and presenting fundamental information that can be used in the development of tissue-engineered substitutes. STATEMENT OF SIGNIFICANCE: This work presents an integration to the approaches currently used to model the mechanical behavior of the meniscal tissue. This study assessed in detail the regional and directional contributions of both the meniscal solid and fluid phases during compressive response, providing also complementary histological evidence. Within this updated perspective, both knee computational modeling and meniscal tissue engineering can be improved to have an effective impact on the clinical practice.
Collapse
|
20
|
Ding G, Gao G, Wu T, Wang J, Hu X, Gong X, Ao Y. A Versatile Surgical Method for Studying Meniscus Implantation in a Rabbit Model. Tissue Eng Part C Methods 2021; 27:481-486. [PMID: 34376080 DOI: 10.1089/ten.tec.2021.0119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Meniscus injury is a health problem that greatly affects people's quality of life. In recent years, the number of diagnosed meniscus injury is increasing year by year. If not treated in time and correctly, it causes severe damages to the cartilage. Owing to the meniscus' limited healing ability, synthetic/tissue-engineered meniscus has emerged as a new treatment modality in recent years. Rabbit models, which have been proved to be a feasible animal model, have been extensively used to study meniscus implantation. However, there is not a unified and minimally invasive surgical method for meniscus implantation in rabbits, and the current surgical methods have unsolved problems, such as long incisions, patella valgus, and cutting of the medial collateral ligament. Therefore, the goal of this study is to provide a minimally invasive and versatile meniscus implantation method. Compared with the control group, our study showed less trauma to the animal model, and we believe that it has the application significance on tissue-engineered meniscus implantation. Impact statement Meniscal injury is a central area of sports medicine research because of the high and increasing global rate. With its profound potential implications for patients' functions and the subsequent development of arthritis, there is a great need for the synthetic/tissue-engineered menisci. Animal meniscus implantation models allow studying meniscus implantation with synthetic/tissue-engineered meniscus, and the rabbit model is a gold method for meniscus implantation in the laboratory. However, there has not yet been a minimally invasive and versatile surgical technique describing this surgery method. This article, therefore, provides a detailed description of the rabbit meniscus implantation method, including step-by-step surgical instructions and accompanying pictures.
Collapse
Affiliation(s)
- Guocheng Ding
- Beijing Key Laboratory of Sports Injuries, Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing, China
| | - Guanying Gao
- Beijing Key Laboratory of Sports Injuries, Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing, China
| | - Tong Wu
- Beijing Key Laboratory of Sports Injuries, Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing, China
| | - Junyan Wang
- Beijing Key Laboratory of Sports Injuries, Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing, China
| | - Xiaoqing Hu
- Beijing Key Laboratory of Sports Injuries, Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing, China
| | - Xi Gong
- Beijing Key Laboratory of Sports Injuries, Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing, China
| | - Yingfang Ao
- Beijing Key Laboratory of Sports Injuries, Department of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing, China
| |
Collapse
|
21
|
High Tibial Osteotomy for Varus Deformity of the Knee. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS GLOBAL RESEARCH AND REVIEWS 2021; 5:01979360-202107000-00006. [PMID: 34242204 PMCID: PMC8274793 DOI: 10.5435/jaaosglobal-d-21-00141] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Accepted: 06/12/2021] [Indexed: 01/13/2023]
Abstract
High tibial osteotomy is a powerful technique to treat symptomatic varus deformity of the knee and is successful when properly indicated and performed. Indications include varus deformity with medial compartment osteoarthritis, cartilage or meniscus pathology. Several techniques exist to correct symptomatic varus malalignment along with concomitant procedures to restore cartilage or meniscus injuries. Evidence supporting high tibial osteotomy for symptomatic medial compartment pathology exists, which provides a durable solution for joint preservation. This review will discuss the indications, techniques, and outcomes for high tibial osteotomies used in the treatment of symptomatic varus deformity of the knee.
Collapse
|
22
|
Wagala NN, Tisherman RT, Lucidi GA, Eads R, Musahl V. Meniscal problems in the ACL deficient knee: What every ACL surgeon must be able to do! OPER TECHN SPORT MED 2021. [DOI: 10.1016/j.otsm.2021.150832] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
23
|
Lucidi GA, Grassi A, Al-zu’bi BBH, Macchiarola L, Agostinone P, Marcacci M, Zaffagnini S. Satisfactory clinical results and low failure rate of medial collagen meniscus implant (CMI) at a minimum 20 years of follow-up. Knee Surg Sports Traumatol Arthrosc 2021; 29:4270-4277. [PMID: 33835226 PMCID: PMC8595163 DOI: 10.1007/s00167-021-06556-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2020] [Accepted: 03/26/2021] [Indexed: 01/03/2023]
Abstract
PURPOSE The aim of the study was to evaluate the long-term clinical results, reoperations, surgical failure and complications at a minimum of 20 year of follow-up of the first 8 medial CMI scaffolds implanted by a single surgeon during a pilot European Prospective study. METHODS Seven (88%) out of 8 patients were contacted. The Cincinnati Score, VAS, and Lysholm score were collected. Moreover, magnetic resonance imaging (MRI) was performed on 4 patients at the last follow-up. Complications, reoperations and failures were also investigated. RESULTS The average follow-up was 21.5 ± 0.5 years. One patient underwent TKA after 13 years from CMI implantation; a second patient underwent valgus high tibial osteotomy 8 years after the index surgery and another patient underwent anterior cruciate ligament hardware removal at 21 years of follow-up. At the final follow-up, 3 patients were rated as "Excellent", 1 as "Good" and 2 as "Fair" according to the Lysholm score. The Cincinnati score and the VAS were substantially stable over time. The MRI showed a mild osteoarthritis progression in 3 out of 4 patients according to the Yulish score, and the CMI signal was similar to the mid-term follow-up revealing 3 cases of myxoid degeneration and 1 case of normal signal with reduced scaffold size. CONCLUSION The medial CMI is a safe procedure: satisfactory clinical results and a low failure rate could be expected even at a long-term follow-up. For this purpose, the correct indication as well as correcting axial malalignment and addressing knee instability at the time of the index surgery is mandatory. On the other hand, a mild osteoarthritis progression could be expected even after meniscus replacement. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- Gian Andrea Lucidi
- IIa Clinica Ortopedica e Traumatologica, IRCCS Istituto Ortopedico Rizzoli, via Cesare Pupilli 1, 40136, Bologna, Italy.
| | - Alberto Grassi
- grid.419038.70000 0001 2154 6641IIa Clinica Ortopedica e Traumatologica, IRCCS Istituto Ortopedico Rizzoli, via Cesare Pupilli 1, 40136 Bologna, Italy
| | - Belal Bashar Hamdan Al-zu’bi
- grid.419038.70000 0001 2154 6641IIa Clinica Ortopedica e Traumatologica, IRCCS Istituto Ortopedico Rizzoli, via Cesare Pupilli 1, 40136 Bologna, Italy
| | - Luca Macchiarola
- grid.419038.70000 0001 2154 6641IIa Clinica Ortopedica e Traumatologica, IRCCS Istituto Ortopedico Rizzoli, via Cesare Pupilli 1, 40136 Bologna, Italy
| | - Piero Agostinone
- grid.419038.70000 0001 2154 6641IIa Clinica Ortopedica e Traumatologica, IRCCS Istituto Ortopedico Rizzoli, via Cesare Pupilli 1, 40136 Bologna, Italy
| | - Maurilio Marcacci
- grid.417728.f0000 0004 1756 8807Humanitas Clinical and Research Center-IRCCS, Via Manzoni 56, 20089 Rozzano, MI Italy
| | - Stefano Zaffagnini
- grid.419038.70000 0001 2154 6641IIa Clinica Ortopedica e Traumatologica, IRCCS Istituto Ortopedico Rizzoli, via Cesare Pupilli 1, 40136 Bologna, Italy
| |
Collapse
|