1
|
Yin B, Wan X, Yue W, Zhou T, Shi L, Wang S, Lin X. A portable automated chip for simultaneous rapid point-of-care testing of multiple β-agonists. Biosens Bioelectron 2023; 239:115586. [PMID: 37603988 DOI: 10.1016/j.bios.2023.115586] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Revised: 08/07/2023] [Accepted: 08/08/2023] [Indexed: 08/23/2023]
Abstract
Abusive use of β-agonists as feed additives for animals and medication is detrimental to human health and food safety. Conventional assays are restricted to a single type of β-agonists detection and cannot match the multiplexing features to perform automated, high throughput, and rapid quantitative analysis in real samples. In this research, we develop a portable automated chip system (PACS) with highly integrated automated devices in conjunction with portable microfluidic chips to provide simultaneous point-of-care testing of multiple β-agonists in the field, simplifying complex manual methods, shortening assay times, and improving sensitivity. Specifically, silicon film is used as reaction substrates for immobilizing the conjugates of β-agonists to increase the sensitivity of the assay result. Then, the PACS with a chemiluminescence imaging detector is established for automatic high-throughput and sensitive detection of Clenbuterol, Ractopamine, and Salbutamol based on the indirect immunoassay. Newly developed chip with high mixing performance can improve the sensitivity of target determination. Multiplex assays were carried out using the developed system for Clenbuterol, Ractopamine, and Salbutamol with a limit of detection of 54 pg mL-1,59 pg mL-1, and 93 pg mL-1, respectively. Except for sample preparation and coating, the detection in the PACS takes less than 47 min. A satisfactory sample recovery (86.33%-108.12%) was obtained, validating the reliability and practical applicability of this PACS. Meanwhile, the PACS enables sensitive and rapid detection of multiple β-agonists in farms or markets where lacking advanced laboratory facilities.
Collapse
Affiliation(s)
- Binfeng Yin
- School of Mechanical Engineering, Yangzhou University, Yangzhou, 225127, China.
| | - Xinhua Wan
- School of Mechanical Engineering, Yangzhou University, Yangzhou, 225127, China
| | - Wenkai Yue
- School of Mechanical Engineering, Yangzhou University, Yangzhou, 225127, China
| | - Teng Zhou
- Mechanical and Electrical Engineering College, Hainan University, Haikou, 570228, China
| | - Liuyong Shi
- Mechanical and Electrical Engineering College, Hainan University, Haikou, 570228, China
| | - Songbai Wang
- School of Chemistry and Chemical Engineering, Shanxi University, Taiyuan, 030006, China.
| | - Xiaodong Lin
- Zhuhai UM Science & Technology Research Institute, Zhuhai, 519000, China.
| |
Collapse
|
2
|
Shen J, Chen Z, Xie R, Li J, Liu C, He Y, Ma X, Yang H, Xie Z. CRISPR/Cas12a-Assisted isothermal amplification for rapid and specific diagnosis of respiratory virus on an microfluidic platform. Biosens Bioelectron 2023; 237:115523. [PMID: 37451024 DOI: 10.1016/j.bios.2023.115523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2023] [Revised: 06/29/2023] [Accepted: 07/07/2023] [Indexed: 07/18/2023]
Abstract
Respiratory viruses have long been a major cause of a global pandemic, emphasizing the urgent need for high-sensitivity diagnostic tools. Typical PCR technology can only determine the type of virus in the sample, which is unable to detect different variants of the same virus without costly and time-consuming gene sequencing. Here, we introduce a simple, fully enclosed, and highly integrated microfluidic system based on CRISPR/Cas12a and isothermal amplification techniques (LOC-CRISPR) that can specifically identify multiple common respiratory viruses and their variants. The LOC-CRISPR chip integrates viral nucleic acid extraction, recombinant polymerase amplification, and CRISPR/Cas12a cleavage reaction-based detection, contamination-free detection. In addition, the LOC-CRISPR chip was designed for multiplexed detection (two-sample input and ten-result outputs), which can not only detect the presence of SARS-CoV-2, H1N1, H3N2, IVB and HRSV but also differentiate the BA.1, BA.2, and BA.5 variants of SARS-COV-2. For clinical validation, the LOC-CRISPR chip was used to analyze 50 nasopharyngeal swab samples (44 positive and 6 negative) and achieved excellent sensitivity (97.8%) and specificity (100%). This innovative LOC-CRISPR system has the ability to quickly, sensitively, and accurately detect multiple target nucleic acid sequences with single-base mutations, which will further improve the rapid identification and traceability of respiratory viruses infectious diseases.
Collapse
Affiliation(s)
- Jienan Shen
- Institute of Pediatrics, Shenzhen Children's Hospital, Clinical Medical College of Southern University of Science and Technology, Shenzhen, 518038, Guangdong, PR China; Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, Guangdong, PR China
| | - Zhi Chen
- Interdisciplinary Center of High Magnetic Field Physics of Shenzhen University, College of Physics and Optoelectronic Engineering, Institute of Microscale Optoelectronics, Shenzhen University, Shenzhen, 518060, PR China; Shenzhen International Institute for Biomedical Research, 3/F, Building 1-B, Silver Star Hi-tech Industrial Park, Longhua District, Shenzhen, 518110, PR China
| | - Ruibin Xie
- Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, Guangdong, PR China
| | - Jingfeng Li
- Interdisciplinary Center of High Magnetic Field Physics of Shenzhen University, College of Physics and Optoelectronic Engineering, Institute of Microscale Optoelectronics, Shenzhen University, Shenzhen, 518060, PR China; Shenzhen International Institute for Biomedical Research, 3/F, Building 1-B, Silver Star Hi-tech Industrial Park, Longhua District, Shenzhen, 518110, PR China
| | - Chunyan Liu
- Department of Dermatology, Longgang District Maternity & Child Healthcare Hospital, Shenzhen, 518172, Guangdong, PR China
| | - Yaqing He
- Institute of Pathogenic Organism, Shenzhen Center for Disease Control and Prevention, Shenzhen, 518055, PR China
| | - Xiaopeng Ma
- Institute of Pediatrics, Shenzhen Children's Hospital, Clinical Medical College of Southern University of Science and Technology, Shenzhen, 518038, Guangdong, PR China
| | - Hui Yang
- Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, Guangdong, PR China.
| | - Zhongjian Xie
- Institute of Pediatrics, Shenzhen Children's Hospital, Clinical Medical College of Southern University of Science and Technology, Shenzhen, 518038, Guangdong, PR China.
| |
Collapse
|
3
|
Jiang Z, Zhuang Y, Guo S, Sohan ASMMF, Yin B. Advances in Microfluidics Techniques for Rapid Detection of Pesticide Residues in Food. Foods 2023; 12:2868. [PMID: 37569137 PMCID: PMC10417549 DOI: 10.3390/foods12152868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 07/24/2023] [Accepted: 07/26/2023] [Indexed: 08/13/2023] Open
Abstract
Food safety is a significant issue that affects people worldwide and is tied to their lives and health. The issue of pesticide residues in food is just one of many issues related to food safety, which leave residues in crops and are transferred through the food chain to human consumption. Foods contaminated with pesticide residues pose a serious risk to human health, including carcinogenicity, neurotoxicity, and endocrine disruption. Although traditional methods, including gas chromatography, high-performance liquid chromatography, chromatography, and mass spectrometry, can be used to achieve a quantitative analysis of pesticide residues, the disadvantages of these techniques, such as being time-consuming and costly and requiring specialist staff, limit their application. Therefore, there is a need to develop rapid, effective, and sensitive equipment for the quantitative analysis of pesticide residues in food. Microfluidics is rapidly emerging in a number of fields due to its outstanding strengths. This paper summarizes the application of microfluidic techniques to pyrethroid, carbamate, organochlorine, and organophosphate pesticides, as well as to commercial products. Meanwhile, the study also outlines the development of microfluidics in combination with 3D printing technology and nanomaterials for detecting pesticide residues in food.
Collapse
Affiliation(s)
- Zhuoao Jiang
- School of Mechanical Engineering, Yangzhou University, Yangzhou 225127, China; (Z.J.); (Y.Z.); (S.G.)
| | - Yu Zhuang
- School of Mechanical Engineering, Yangzhou University, Yangzhou 225127, China; (Z.J.); (Y.Z.); (S.G.)
| | - Shentian Guo
- School of Mechanical Engineering, Yangzhou University, Yangzhou 225127, China; (Z.J.); (Y.Z.); (S.G.)
| | - A. S. M. Muhtasim Fuad Sohan
- Faculty of Engineering, Department of Mechanical Engineering, The University of Adelaide, Adelaide, SA 5000, Australia;
| | - Binfeng Yin
- School of Mechanical Engineering, Yangzhou University, Yangzhou 225127, China; (Z.J.); (Y.Z.); (S.G.)
| |
Collapse
|
4
|
Point-of-care diagnostics for sepsis using clinical biomarkers and microfluidic technology. Biosens Bioelectron 2023; 227:115181. [PMID: 36867959 DOI: 10.1016/j.bios.2023.115181] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 02/13/2023] [Accepted: 02/23/2023] [Indexed: 03/05/2023]
Abstract
Sepsis is a life-threatening immune response which is caused by a wide variety of sources and is a leading cause of mortality globally. Rapid diagnosis and appropriate antibiotic treatment are critical for successful patient outcomes; however, current molecular diagnostic techniques are time-consuming, costly and require trained personnel. Additionally, there is a lack of rapid point-of-care (POC) devices available for sepsis detection despite the urgent requirements in emergency departments and low-resource areas. Recent advances have been made toward developing a POC test for early sepsis detection that will be more rapid and accurate compared to conventional techniques. Within this context, this review discusses the use of current and novel biomarkers for early sepsis diagnosis using microfluidics devices for POC testing.
Collapse
|
5
|
Huang J, Zhang T, Zheng Y, Liu J. Dual-Mode Sensing Platform for Cancer Antigen 15-3 Determination Based on a Silica Nanochannel Array Using Electrochemiluminescence and Electrochemistry. BIOSENSORS 2023; 13:bios13030317. [PMID: 36979529 PMCID: PMC10046297 DOI: 10.3390/bios13030317] [Citation(s) in RCA: 17] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 02/15/2023] [Accepted: 02/21/2023] [Indexed: 06/01/2023]
Abstract
An electrochemiluminescence-electrochemistry (ECL-EC) dual-mode sensing platform based on a vertically-ordered mesoporous silica films (VMSF) modified electrode was designed here for the sensitive and selective determination of cancer antigen 15-3 (CA 15-3), a specific biomarker of breast cancer. VMSF was assembled through a rapid electrochemically assisted self-assembly (EASA) method and plays a crucial role in signal amplification via a strong electrostatic interaction with the positively charged bifunctional probe Ru(bpy)32+. To construct the biorecognition interface, epoxy functional silane was linked to the surface of VMSF for further covalent immobilization of the antibody. As a benefit from the specific combination of antigen and antibody, a non-conductive immunocomplex layer was formed in the presence of CA 15-3, leading to the hinderance of the mass and electron transfer of the probes. Based on this strategy, the dual-mode determination of CA 15-3 ranging from 0.1 mU/mL to 100 mU/mL with a LOD of 9 μU/mL for ECL mode, and 10 mU/mL to 200 U/mL with a LOD of 5.4 mU/mL for EC mode, was achieved. The proposed immunosensor was successfully employed for the detection of CA 15-3 in human serum without tedious pretreatment.
Collapse
Affiliation(s)
- Jie Huang
- Key Laboratory of Surface & Interface Science of Polymer Materials of Zhejiang Province, Department of Chemistry, Zhejiang Sci-Tech University, Hangzhou 310018, China
| | - Tongtong Zhang
- Key Laboratory of Integrated Oncology and Intelligent Medicine of Zhejiang Province, Department of Hepatobiliary and Pancreatic Surgery, Affiliated Hangzhou First People’s Hospital, Zhejiang University School of Medicine, Hangzhou 310006, China
| | - Yanyan Zheng
- Key Laboratory of Surface & Interface Science of Polymer Materials of Zhejiang Province, Department of Chemistry, Zhejiang Sci-Tech University, Hangzhou 310018, China
| | - Jiyang Liu
- Key Laboratory of Surface & Interface Science of Polymer Materials of Zhejiang Province, Department of Chemistry, Zhejiang Sci-Tech University, Hangzhou 310018, China
| |
Collapse
|
6
|
Yin B, Qian C, Wan X, Muhtasim Fuad Sohan A, Lin X. Tape integrated self-designed microfluidic chip for point-of-care immunoassays simultaneous detection of disease biomarkers with tunable detection range. Biosens Bioelectron 2022; 212:114429. [DOI: 10.1016/j.bios.2022.114429] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Revised: 05/19/2022] [Accepted: 05/24/2022] [Indexed: 01/04/2023]
|
7
|
Yin B, Wan X, Sohan ASMMF, Lin X. Microfluidics-Based POCT for SARS-CoV-2 Diagnostics. MICROMACHINES 2022; 13:mi13081238. [PMID: 36014162 PMCID: PMC9413395 DOI: 10.3390/mi13081238] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 07/30/2022] [Accepted: 07/30/2022] [Indexed: 11/17/2022]
Abstract
A microfluidic chip is a tiny reactor that can confine and flow a specific amount of fluid into channels of tens to thousands of microns as needed and can precisely control fluid flow, pressure, temperature, etc. Point-of-care testing (POCT) requires small equipment, has short testing cycles, and controls the process, allowing single or multiple laboratory facilities to simultaneously analyze biological samples and diagnose infectious diseases. In general, rapid detection and stage assessment of viral epidemics are essential to overcome pandemic situations and diagnose promptly. Therefore, combining microfluidic devices with POCT improves detection efficiency and convenience for viral disease SARS-CoV-2. At the same time, the POCT of microfluidic chips increases user accessibility, improves accuracy and sensitivity, shortens detection time, etc., which are beneficial in detecting SARS-CoV-2. This review shares recent advances in POCT-based testing for COVID-19 and how it is better suited to help diagnose in response to the ongoing pandemic.
Collapse
Affiliation(s)
- Binfeng Yin
- School of Mechanical Engineering, Yangzhou University, Yangzhou 225127, China; (X.W.); (A.S.M.M.F.S.)
- Correspondence: (B.Y.); (X.L.); Tel.: +86-189-1118-5500 (B.Y.); +86-182-2266-7931 (X.L.)
| | - Xinhua Wan
- School of Mechanical Engineering, Yangzhou University, Yangzhou 225127, China; (X.W.); (A.S.M.M.F.S.)
| | | | - Xiaodong Lin
- College of Food and Biological Engineering, Zhengzhou University of Light Industry, Zhengzhou 450001, China
- Correspondence: (B.Y.); (X.L.); Tel.: +86-189-1118-5500 (B.Y.); +86-182-2266-7931 (X.L.)
| |
Collapse
|