Liu W, Wang D, He G, Li T, Zhang X. A novel porous titanium with engineered surface for bone defect repair in load-bearing position. J Biomed Mater Res A 2024; 112:1083-1092. [PMID: 38411355 DOI: 10.1002/jbm.a.37689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2023] [Revised: 02/01/2024] [Accepted: 02/06/2024] [Indexed: 02/28/2024]
Abstract
Porous titanium exhibits low elastic modulus and porous structure is thought to be a promising implant in bone defect repair. However, the bioinert and low mechanical strength of porous titanium have limited its clinical application, especially in load-bearing bone defect repair. Our previous study has reported an infiltration casting and acid corrosion (IC-AC) method to fabricate a novel porous titanium (pTi) with 40% porosity and 0.4 mm pore diameter, which exerts mechanical property matching with cortical bone and interconnected channels. In this study, we introduced a nanoporous coating and incorporated an osteogenic element strontium (Sr) on the surface of porous titanium (named as Sr-micro arch oxidation [MAO]) to improve the osteogenic ability of the pTi by MAO. Better biocompatibility of Sr-MAO was verified by cell adhesion experiment and cell counting kit-8 (CCK-8) test. The in vitro osteogenic-related tests such as immunofluorescence staining, alkaline phosphatase staining and real-time polymerase chain reaction (RT-PCR) demonstrated better osteogenic ability of Sr-MAO. Femoral bone defect repair model was employed to evaluate the osseointegration of samples in vivo. Results of micro-CT scanning, sequential fluorochrome labeling and Van Gieson staining suggested that Sr-MAO showed better in vivo osteogenic ability than other groups. Taking results of both in vitro and in vivo experiment together, this study indicated the Sr-MAO porous titanium could be a promising implant load-bearing bone defect.
Collapse
Affiliation(s)
- Wei Liu
- Department of Orthopaedics, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Dong Wang
- School of Mechanical and Electrical Engineering, Henan University of Technology, Zhengzhou, China
| | - Guo He
- State Key Lab of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Tingting Li
- Department of Infection Disease, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Xianlong Zhang
- Department of Orthopaedics, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| |
Collapse
|
2
|
Verbist M, Vandevelde AL, Geusens J, Sun Y, Shaheen E, Willaert R. Reconstruction of Craniomaxillofacial Bone Defects with 3D-Printed Bioceramic Implants: Scoping Review and Clinical Case Series. J Clin Med 2024; 13:2805. [PMID: 38792347 PMCID: PMC11122134 DOI: 10.3390/jcm13102805] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Revised: 04/27/2024] [Accepted: 05/08/2024] [Indexed: 05/26/2024] Open
Abstract
Reconstruction of craniomaxillofacial bone defects using 3D-printed hydroxyapatite (HA) bioceramic patient-specific implants (PSIs) is a new technique with great potential. This study aimed to investigate the advantages, disadvantages, and clinical outcomes of these implants in craniomaxillofacial surgeries. The PubMed and Embase databases were searched for patients with craniomaxillofacial bone defects treated with bioceramic PSIs. Clinical outcomes such as biocompatibility, biomechanical properties, and aesthetics were evaluated and compared to those of commonly used titanium or poly-ether-ether-ketone (PEEK) implants and autologous bone grafts. Two clinical cases are presented to illustrate the surgical procedure and clinical outcomes of HA bioceramic PSIs. Literature review showed better a biocompatibility of HA PSIs than titanium and PEEK. The initial biomechanical properties were inferior to those of autologous bone grafts, PEEK, and titanium but improved when integrated. Satisfactory aesthetic results were found in our two clinical cases with good stability and absence of bone resorption or infection. Radiological signs of osteogenesis were observed in the two clinical cases six months postoperatively. HA bioceramic PSIs have excellent biocompatible properties and imitate natural bone biomechanically and radiologically. They are a well-suited alternative for conventional biomaterials in the reconstruction of load-sharing bone defects in the craniomaxillofacial region.
Collapse
Affiliation(s)
- Maarten Verbist
- Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, 3000 Leuven, Belgium
- OMFS IMPATH Research Group: Department of Oral and Maxillofacial Surgery, Imaging and Pathology, Leuven University Hospitals, 3000 Leuven, Belgium
| | - Anne-Laure Vandevelde
- Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, 3000 Leuven, Belgium
- OMFS IMPATH Research Group: Department of Oral and Maxillofacial Surgery, Imaging and Pathology, Leuven University Hospitals, 3000 Leuven, Belgium
| | - Joris Geusens
- Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, 3000 Leuven, Belgium
- OMFS IMPATH Research Group: Department of Oral and Maxillofacial Surgery, Imaging and Pathology, Leuven University Hospitals, 3000 Leuven, Belgium
| | - Yi Sun
- Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, 3000 Leuven, Belgium
- OMFS IMPATH Research Group: Department of Oral and Maxillofacial Surgery, Imaging and Pathology, Leuven University Hospitals, 3000 Leuven, Belgium
| | - Eman Shaheen
- Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, 3000 Leuven, Belgium
- OMFS IMPATH Research Group: Department of Oral and Maxillofacial Surgery, Imaging and Pathology, Leuven University Hospitals, 3000 Leuven, Belgium
| | - Robin Willaert
- Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, 3000 Leuven, Belgium
- OMFS IMPATH Research Group: Department of Oral and Maxillofacial Surgery, Imaging and Pathology, Leuven University Hospitals, 3000 Leuven, Belgium
| |
Collapse
|
3
|
Jing Z, Yuan W, Wang J, Ni R, Qin Y, Mao Z, Wei F, Song C, Zheng Y, Cai H, Liu Z. Simvastatin/hydrogel-loaded 3D-printed titanium alloy scaffolds suppress osteosarcoma via TF/NOX2-associated ferroptosis while repairing bone defects. Bioact Mater 2024; 33:223-241. [PMID: 38045570 PMCID: PMC10689208 DOI: 10.1016/j.bioactmat.2023.11.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Revised: 10/18/2023] [Accepted: 11/02/2023] [Indexed: 12/05/2023] Open
Abstract
Postoperative anatomical reconstruction and prevention of local recurrence after tumor resection are two vital clinical challenges in osteosarcoma treatment. A three-dimensional (3D)-printed porous Ti6Al4V scaffold (3DTi) is an ideal material for reconstructing critical bone defects with numerous advantages over traditional implants, including a lower elasticity modulus, stronger bone-implant interlock, and larger drug-loading space. Simvastatin is a multitarget drug with anti-tumor and osteogenic potential; however, its efficiency is unsatisfactory when delivered systematically. Here, simvastatin was loaded into a 3DTi using a thermosensitive poly (lactic-co-glycolic) acid (PLGA)-polyethylene glycol (PEG)-PLGA hydrogel as a carrier to exert anti-osteosarcoma and osteogenic effects. Newly constructed simvastatin/hydrogel-loaded 3DTi (Sim-3DTi) was comprehensively appraised, and its newfound anti-osteosarcoma mechanism was explained. Specifically, in a bone defect model of rabbit condyles, Sim-3DTi exhibited enhanced osteogenesis, bone in-growth, and osseointegration compared with 3DTi alone, with greater bone morphogenetic protein 2 expression. In our nude mice model, simvastatin loading reduced tumor volume by 59%-77 % without organic damage, implying good anti-osteosarcoma activity and biosafety. Furthermore, Sim-3DTi induced ferroptosis by upregulating transferrin and nicotinamide adenine dinucleotide phosphate oxidase 2 levels in osteosarcoma both in vivo and in vitro. Sim-3DTi is a promising osteogenic bone substitute for osteosarcoma-related bone defects, with a ferroptosis-mediated anti-osteosarcoma effect.
Collapse
Affiliation(s)
- Zehao Jing
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
- Beijing Key Laboratory of Spinal Disease Research, Beijing, 100191, People's Republic of China
| | - Wanqiong Yuan
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
- Beijing Key Laboratory of Spinal Disease Research, Beijing, 100191, People's Republic of China
| | - Jiedong Wang
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
- Beijing Key Laboratory of Spinal Disease Research, Beijing, 100191, People's Republic of China
| | - Renhua Ni
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
- Beijing Key Laboratory of Spinal Disease Research, Beijing, 100191, People's Republic of China
| | - Yu Qin
- School of Materials Science and Engineering, Peking University, Beijing, 100871, People's Republic of China
| | - Zhinan Mao
- School of Materials Science and Engineering, Peking University, Beijing, 100871, People's Republic of China
| | - Feng Wei
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
- Beijing Key Laboratory of Spinal Disease Research, Beijing, 100191, People's Republic of China
| | - Chunli Song
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
| | - Yufeng Zheng
- School of Materials Science and Engineering, Peking University, Beijing, 100871, People's Republic of China
| | - Hong Cai
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
| | - Zhongjun Liu
- Department of Orthopedics, Peking University Third Hospital, Beijing, 100191, People's Republic of China
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191, People's Republic of China
- Beijing Key Laboratory of Spinal Disease Research, Beijing, 100191, People's Republic of China
| |
Collapse
|
4
|
Zhou J, Georgas E, Su Y, Zhou J, Kröger N, Benn F, Kopp A, Qin Y, Zhu D. Evolution from Bioinert to Bioresorbable: In Vivo Comparative Study of Additively Manufactured Metal Bone Scaffolds. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2302702. [PMID: 37424385 PMCID: PMC10502659 DOI: 10.1002/advs.202302702] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Indexed: 07/11/2023]
Abstract
Additively manufactured scaffolds offer significant potential for treating bone defects, owing to their porous, customizable architecture and functionalization capabilities. Although various biomaterials have been investigated, metals - the most successful orthopedic material - have yet to yield satisfactory results. Conventional bio-inert metals, such as titanium (Ti) and its alloys, are widely used for fixation devices and reconstructive implants, but their non-bioresorbable nature and the mechanical property mismatch with human bones limit their application as porous scaffolds for bone regeneration. Advancements in additive manufacturing have facilitated the use of bioresorbable metals, including magnesium (Mg), zinc (Zn), and their alloys, as porous scaffolds via Laser Powder Bed Fusion (L-PBF) technology. This in vivo study presents a comprehensive, side-by-side comparative analysis of the interactions between bone regeneration and additively manufactured bio-inert/bioresorbable metal scaffolds, as well as their therapeutic outcomes. The research offers an in-depth understanding of the metal scaffold-assisted bone healing process, illustrating that Mg and Zn scaffolds contribute to the bone healing process in distinct ways, but ultimately deliver superior therapeutic outcomes compared to Ti scaffolds. These findings suggest that bioresorbable metal scaffolds hold considerable promise for the clinical treatment of bone defects in the near future.
Collapse
Affiliation(s)
- Juncen Zhou
- Department of Biomedical EngineeringUniversity of Stony BrookStony BrookNY11794USA
| | - Elias Georgas
- Department of Biomedical EngineeringUniversity of Stony BrookStony BrookNY11794USA
| | - Yingchao Su
- Department of Biomedical EngineeringUniversity of Stony BrookStony BrookNY11794USA
| | - Jiayi Zhou
- Department of Biomedical EngineeringUniversity of Stony BrookStony BrookNY11794USA
| | - Nadja Kröger
- Division of Plastic‐Reconstructive‐ and Aesthetic SurgeryUniversity Hospital Cologne50937CologneGermany
| | | | | | - Yi‐Xian Qin
- Department of Biomedical EngineeringUniversity of Stony BrookStony BrookNY11794USA
| | - Donghui Zhu
- Department of Biomedical EngineeringUniversity of Stony BrookStony BrookNY11794USA
| |
Collapse
|
5
|
Palmquist A, Jolic M, Hryha E, Shah FA. Complex geometry and integrated macro-porosity: Clinical applications of electron beam melting to fabricate bespoke bone-anchored implants. Acta Biomater 2023; 156:125-145. [PMID: 35675890 DOI: 10.1016/j.actbio.2022.06.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 05/16/2022] [Accepted: 06/01/2022] [Indexed: 01/18/2023]
Abstract
The last decade has witnessed rapid advancements in manufacturing technologies for biomedical implants. Additive manufacturing (or 3D printing) has broken down major barriers in the way of producing complex 3D geometries. Electron beam melting (EBM) is one such 3D printing process applicable to metals and alloys. EBM offers build rates up to two orders of magnitude greater than comparable laser-based technologies and a high vacuum environment to prevent accumulation of trace elements. These features make EBM particularly advantageous for materials susceptible to spontaneous oxidation and nitrogen pick-up when exposed to air (e.g., titanium and titanium-based alloys). For skeletal reconstruction(s), anatomical mimickry and integrated macro-porous architecture to facilitate bone ingrowth are undoubtedly the key features of EBM manufactured implants. Using finite element modelling of physiological loading conditions, the design of a prosthesis may be further personalised. This review looks at the many unique clinical applications of EBM in skeletal repair and the ground-breaking innovations in prosthetic rehabilitation. From a simple acetabular cup to the fifth toe, from the hand-wrist complex to the shoulder, and from vertebral replacement to cranio-maxillofacial reconstruction, EBM has experienced it all. While sternocostal reconstructions might be rare, the repair of long bones using EBM manufactured implants is becoming exceedingly frequent. Despite the various merits, several challenges remain yet untackled. Nevertheless, with the capability to produce osseointegrating implants of any conceivable shape/size, and permissive of bone ingrowth and functional loading, EBM can pave the way for numerous fascinating and novel applications in skeletal repair, regeneration, and rehabilitation. STATEMENT OF SIGNIFICANCE: Electron beam melting (EBM) offers unparalleled possibilities in producing contaminant-free, complex and intricate geometries from alloys of biomedical interest, including Ti6Al4V and CoCr. We review the diverse range of clinical applications of EBM in skeletal repair, both as mass produced off-the-shelf implants and personalised, patient-specific prostheses. From replacing large volumes of disease-affected bone to complex, multi-material reconstructions, almost every part of the human skeleton has been replaced with an EBM manufactured analog to achieve macroscopic anatomical-mimickry. However, various questions regarding long-term performance of patient-specific implants remain unaddressed. Directions for further development include designing personalised implants and prostheses based on simulated loading conditions and accounting for trabecular bone microstructure with respect to physiological factors such as patient's age and disease status.
Collapse
Affiliation(s)
- Anders Palmquist
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
| | - Martina Jolic
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Eduard Hryha
- Department of Materials and Manufacturing Technologies, Chalmers University of Technology, Gothenburg, Sweden
| | - Furqan A Shah
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
| |
Collapse
|
6
|
Ríos-Puerta K, Gutiérrez-Florez OD. Aleaciones metálicas para aplicaciones ortopédicas: una revisión sobre su respuesta al estrés fisiológico y a los procesos de corrosión. REVISTA POLITÉCNICA 2022. [DOI: 10.33571/rpolitec.v18n35a2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
El campo de los biomateriales y sus aplicaciones contribuyen significativamente a la salud y calidad de vida de las personas. Aunque existen varios grupos de biomateriales como cerámicos, polímeros, metales y todos en un determinado porcentaje se utilizan para diferentes procedimientos con objetivos específicos, este artículo de revisión se centra en los metales y sus aleaciones, la resistencia de estos a la corrosión en un entorno biológico y la protección contra el estrés fisiológico. Para esta revisión se seleccionaron artículos que permiten describir dichos aspectos de las aleaciones metálicas utilizadas en aplicaciones ortopédicas partiendo de una detallada búsqueda electrónica, a partir de ello, se concluye que la resistencia a la corrosión y el estrés fisiológico son dos aspectos tan neurálgicos que muchas de las investigaciones realizadas tienen como objetivo mejorarlos garantizando el éxito de la osteosíntesis y la recuperación satisfactoria del paciente.
The field of biomaterials and their applications contribute significantly to the health and quality of life of people. Although there are several groups of biomaterials such as ceramics, polymers, metals and all of them in a certain percentage are used for different procedures with specific objectives, this review article focuses on metals and their alloys, their resistance to corrosion in a biological environment and protection against physiological stress. For this review, articles were selected to describe these aspects of metal alloys used in orthopedic applications based on a detailed electronic search. From this, it is concluded that resistance to corrosion and physiological stress are two aspects so crucial that many of the researches carried out aim to improve them to ensure the success of osteosynthesis and the satisfactory recovery of the patient.
Collapse
|
7
|
Shin YC, Bae JH, Lee JH, Raja IS, Kang MS, Kim B, Hong SW, Huh JB, Han DW. Enhanced osseointegration of dental implants with reduced graphene oxide coating. Biomater Res 2022; 26:11. [PMID: 35313996 PMCID: PMC8935794 DOI: 10.1186/s40824-022-00257-7] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Accepted: 02/24/2022] [Indexed: 01/15/2023] Open
Abstract
BACKGROUND The implants of pure titanium (Ti) and its alloys can lead to implant failure because of their poor interaction with bone-associated cells during bone regeneration. Surface modification over implants has achieved successful implants for enhanced osseointegration. Herein, we report a robust strategy to implement bioactive surface modification for implant interface enabled by the combinatorial system of reduced graphene oxide (rGO)-coated sandblasted, large-grit, and acid-etched (SLA) Ti to impart benefits to the implant. METHODS We prepared SLA Ti (ST) implants with different surface modifications [i.e., rGO and recombinant human bone morphogenetic protein-2 (rhBMP-2)] and investigated their dental tissue regenerating ability in animal models. We performed comparative studies in surface property, in vitro cellular behaviors, and in vivo osseointegration activity among different groups, including ST (control), rhBMP-2-immobilized ST (BI-ST), rhBMP-2-treated ST (BT-ST), and rGO-coated ST (R-ST). RESULTS Spectroscopic, diffractometric, and microscopic analyses confirmed that rGO was coated well around the surfaces of Ti discs (for cell study) and implant fixtures (for animal study). Furthermore, in vitro and in vivo studies revealed that the R-ST group showed significantly better effects in cell attachment and proliferation, alkaline phosphatase activity, matrix mineralization, expression of osteogenesis-related genes and protein, and osseointegration than the control (ST), BI-ST, and BT-ST groups. CONCLUSION Hence, we suggest that the rGO-coated Ti can be a promising candidate for the application to dental or even orthopedic implants due to its ability to accelerate the healing rate with the high potential of osseointegration.
Collapse
Affiliation(s)
- Yong Cheol Shin
- Department of Cogno-Mechatronics Engineering, College of Nanoscience & Nanotechnology, Pusan National University, Busan, 46241 South Korea
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX 78712 USA
| | - Ji-Hyeon Bae
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, 50612 South Korea
| | - Jong Ho Lee
- Daan Korea Corporation, Seoul, 06252 South Korea
| | | | - Moon Sung Kang
- Department of Cogno-Mechatronics Engineering, College of Nanoscience & Nanotechnology, Pusan National University, Busan, 46241 South Korea
| | - Bongju Kim
- Dental Life Science Research Institute / Innovation Research & Support Center for Dental Science, Seoul National University Dental Hospital, Seoul, 03080 South Korea
| | - Suck Won Hong
- Department of Cogno-Mechatronics Engineering, College of Nanoscience & Nanotechnology, Pusan National University, Busan, 46241 South Korea
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, 50612 South Korea
| | - Dong-Wook Han
- Department of Cogno-Mechatronics Engineering, College of Nanoscience & Nanotechnology, Pusan National University, Busan, 46241 South Korea
- Bio-IT Fusion Technology Research Institute, Pusan National University, Busan, 46241 South Korea
| |
Collapse
|