Colachis M, Schlink BR, Colachis S, Shqau K, Huegen BL, Palmer K, Heintz A. Benchtop Performance of Novel Mixed Ionic-Electronic Conductive Electrode Form Factors for Biopotential Recordings. SENSORS (BASEL, SWITZERLAND) 2024; 24:3136. [PMID: 38793990 PMCID: PMC11125343 DOI: 10.3390/s24103136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2024] [Revised: 05/02/2024] [Accepted: 05/10/2024] [Indexed: 05/26/2024]
Abstract
Background: Traditional gel-based (wet) electrodes for biopotential recordings have several shortcomings that limit their practicality for real-world measurements. Dry electrodes may improve usability, but they often suffer from reduced signal quality. We sought to evaluate the biopotential recording properties of a novel mixed ionic-electronic conductive (MIEC) material for improved performance. Methods: We fabricated four MIEC electrode form factors and compared their signal recording properties to two control electrodes, which are electrodes commonly used for biopotential recordings (Ag-AgCl and stainless steel). We used an agar synthetic skin to characterize the impedance of each electrode form factor. An electrical phantom setup allowed us to compare the recording quality of simulated biopotentials with ground-truth sources. Results: All MIEC electrode form factors yielded impedances in a similar range to the control electrodes (all <80 kΩ at 100 Hz). Three of the four MIEC samples produced similar signal-to-noise ratios and interfacial charge transfers as the control electrodes. Conclusions: The MIEC electrodes demonstrated similar and, in some cases, better signal recording characteristics than current state-of-the-art electrodes. MIEC electrodes can also be fabricated into a myriad of form factors, underscoring the great potential this novel material has across a wide range of biopotential recording applications.
Collapse
Affiliation(s)
- Matthew Colachis
- Battelle Memorial Institute, 505 King Ave., Columbus, OH 43201, USA; (B.R.S.); (K.S.); (K.P.); (A.H.)
| | - Bryan R. Schlink
- Battelle Memorial Institute, 505 King Ave., Columbus, OH 43201, USA; (B.R.S.); (K.S.); (K.P.); (A.H.)
| | - Sam Colachis
- Battelle Memorial Institute, 505 King Ave., Columbus, OH 43201, USA; (B.R.S.); (K.S.); (K.P.); (A.H.)
| | - Krenar Shqau
- Battelle Memorial Institute, 505 King Ave., Columbus, OH 43201, USA; (B.R.S.); (K.S.); (K.P.); (A.H.)
| | - Brittani L. Huegen
- UES, a BlueHalo Company, 4401 Dayton Xenia Road, Beavercreek, OH 45432, USA;
| | - Katherine Palmer
- Battelle Memorial Institute, 505 King Ave., Columbus, OH 43201, USA; (B.R.S.); (K.S.); (K.P.); (A.H.)
| | - Amy Heintz
- Battelle Memorial Institute, 505 King Ave., Columbus, OH 43201, USA; (B.R.S.); (K.S.); (K.P.); (A.H.)
| |
Collapse
|
2
|
Ding Y, Jiang J, Wu Y, Zhang Y, Zhou J, Zhang Y, Huang Q, Zheng Z. Porous Conductive Textiles for Wearable Electronics. Chem Rev 2024; 124:1535-1648. [PMID: 38373392 DOI: 10.1021/acs.chemrev.3c00507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/21/2024]
Abstract
Over the years, researchers have made significant strides in the development of novel flexible/stretchable and conductive materials, enabling the creation of cutting-edge electronic devices for wearable applications. Among these, porous conductive textiles (PCTs) have emerged as an ideal material platform for wearable electronics, owing to their light weight, flexibility, permeability, and wearing comfort. This Review aims to present a comprehensive overview of the progress and state of the art of utilizing PCTs for the design and fabrication of a wide variety of wearable electronic devices and their integrated wearable systems. To begin with, we elucidate how PCTs revolutionize the form factors of wearable electronics. We then discuss the preparation strategies of PCTs, in terms of the raw materials, fabrication processes, and key properties. Afterward, we provide detailed illustrations of how PCTs are used as basic building blocks to design and fabricate a wide variety of intrinsically flexible or stretchable devices, including sensors, actuators, therapeutic devices, energy-harvesting and storage devices, and displays. We further describe the techniques and strategies for wearable electronic systems either by hybridizing conventional off-the-shelf rigid electronic components with PCTs or by integrating multiple fibrous devices made of PCTs. Subsequently, we highlight some important wearable application scenarios in healthcare, sports and training, converging technologies, and professional specialists. At the end of the Review, we discuss the challenges and perspectives on future research directions and give overall conclusions. As the demand for more personalized and interconnected devices continues to grow, PCT-based wearables hold immense potential to redefine the landscape of wearable technology and reshape the way we live, work, and play.
Collapse
Affiliation(s)
- Yichun Ding
- School of Fashion and Textiles, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong SAR 999077, P. R. China
- Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, Fuzhou, Fujian 350108, P. R. China
- Fujian Science & Technology Innovation Laboratory for Optoelectronic Information of China, Fuzhou, Fujian 350108, P. R. China
| | - Jinxing Jiang
- School of Fashion and Textiles, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong SAR 999077, P. R. China
| | - Yingsi Wu
- School of Fashion and Textiles, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong SAR 999077, P. R. China
| | - Yaokang Zhang
- School of Fashion and Textiles, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong SAR 999077, P. R. China
| | - Junhua Zhou
- School of Fashion and Textiles, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong SAR 999077, P. R. China
| | - Yufei Zhang
- School of Fashion and Textiles, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong SAR 999077, P. R. China
| | - Qiyao Huang
- School of Fashion and Textiles, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong SAR 999077, P. R. China
- Research Institute for Intelligent Wearable Systems, The Hong Kong Polytechnic University, Hong Kong SAR 999077, P. R. China
| | - Zijian Zheng
- School of Fashion and Textiles, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong SAR 999077, P. R. China
- Department of Applied Biology and Chemical Technology, Faculty of Science, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong SAR 999077, P. R. China
- Research Institute for Intelligent Wearable Systems, The Hong Kong Polytechnic University, Hong Kong SAR 999077, P. R. China
- Research Institute for Smart Energy, The Hong Kong Polytechnic University, Hong Kong SAR 999077, P. R. China
| |
Collapse
|
3
|
Zuccaroli I, Lucke-Wold B, Palla A, Eremiev A, Sorrentino Z, Zakare-Fagbamila R, McNulty J, Christie C, Chandra V, Mampre D. Neural Bypasses: Literature Review and Future Directions in Developing Artificial Neural Connections. OBM NEUROBIOLOGY 2023; 7:158. [PMID: 36908763 PMCID: PMC9997488 DOI: 10.21926/obm.neurobiol.2301158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/24/2023]
Abstract
Reported neuro-modulation schemes in the literature are typically classified as closed-loop or open-loop. A novel group of recently developed neuro-modulation devices may be better described as a neural bypass, which attempts to transmit neural data from one location of the nervous system to another. The most common form of neural bypasses in the literature utilize EEG recordings of cortical information paired with functional electrical stimulation for effector muscle output, most commonly for assistive applications and rehabilitation in spinal cord injury or stroke. Other neural bypass locations that have also been described, or may soon be in development, include cortical-spinal bypasses, cortical-cortical bypasses, autonomic bypasses, peripheral-central bypasses, and inter-subject bypasses. The most common recording devices include EEG, ECoG, and microelectrode arrays, while stimulation devices include both invasive and noninvasive electrodes. Several devices are in development to improve the temporal and spatial resolution and biocompatibility for neuronal recording and stimulation. A major barrier to entry includes neuroplasticity and current decoding mechanisms that regularly require retraining. Neural bypasses are a unique class of neuro-modulation. Continued advancement of neural recording and stimulating devices with high spatial and temporal resolution, combined with decoding mechanisms uninhibited by neuroplasticity, can expand the therapeutic capability of neural bypassing. Overall, neural bypasses are a promising modality to improve the treatment of common neurologic disorders, including stroke, spinal cord injury, peripheral nerve injury, brain injury and more.
Collapse
Affiliation(s)
| | | | | | - Alexander Eremiev
- Department of Neurosurgery, New York University School of Medicine, New York, USA
| | | | | | - Jack McNulty
- Department of Neurosurgery, University of Iowa, Iowa City, IA, USA
| | - Carlton Christie
- Department of Neurosurgery, University of Florida, Gainesville, USA
| | - Vyshak Chandra
- Department of Neurosurgery, University of Florida, Gainesville, USA
| | - David Mampre
- Johns Hopkins University, Baltimore, USA
- Department of Neurosurgery, University of Florida, Gainesville, USA
| |
Collapse
|
4
|
Pavlov VA, Tracey KJ. Bioelectronic medicine: Preclinical insights and clinical advances. Neuron 2022; 110:3627-3644. [PMID: 36174571 PMCID: PMC10155266 DOI: 10.1016/j.neuron.2022.09.003] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2022] [Revised: 07/28/2022] [Accepted: 09/02/2022] [Indexed: 11/17/2022]
Abstract
The nervous system maintains homeostasis and health. Homeostatic disruptions underlying the pathobiology of many diseases can be controlled by bioelectronic devices targeting CNS and peripheral neural circuits. New insights into the regulatory functions of the nervous system and technological developments in bioelectronics drive progress in the emerging field of bioelectronic medicine. Here, we provide an overview of key aspects of preclinical research, translation, and clinical advances in bioelectronic medicine.
Collapse
Affiliation(s)
- Valentin A Pavlov
- Institute of Bioelectronic Medicine, the Feinstein Institutes for Medical Research, Northwell Health, Manhasset, NY, USA; Elmezzi Graduate School of Molecular Medicine, Northwell Health, Manhasset, NY, USA; Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY, USA.
| | - Kevin J Tracey
- Institute of Bioelectronic Medicine, the Feinstein Institutes for Medical Research, Northwell Health, Manhasset, NY, USA; Elmezzi Graduate School of Molecular Medicine, Northwell Health, Manhasset, NY, USA; Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY, USA.
| |
Collapse
|
5
|
Wright JP, Mughrabi IT, Wong J, Mathew J, Jayaprakash N, Crosfield C, Chang EH, Chavan SS, Tracey KJ, Pavlov VA, Al-Abed Y, Zanos TP, Zanos S, Datta-Chaudhuri T. A fully implantable wireless bidirectional neuromodulation system for mice. Biosens Bioelectron 2022; 200:113886. [PMID: 34995836 PMCID: PMC9258776 DOI: 10.1016/j.bios.2021.113886] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 12/02/2021] [Accepted: 12/10/2021] [Indexed: 01/09/2023]
Abstract
Novel research in the field of bioelectronic medicine requires neuromodulation systems that pair high-performance neurostimulation and bio-signal acquisition hardware with advanced signal processing and control algorithms. Although mice are the most commonly used animal in medical research, the size, weight, and power requirements of such bioelectronic systems either preclude use in mice or impose significant constraints on experimental design. Here, a fully-implantable recording and stimulation neuromodulation system suitable for use in mice is presented, measuring 2.2 cm3 and weighing 2.8 g. The bidirectional wireless interface allows simultaneous readout of multiple physiological signals and complete control over stimulation parameters, and a wirelessly rechargeable battery provides a lifetime of up to 5 days on a single charge. The device was implanted to deliver vagus nerve stimulation (n = 12 animals) and a functional neural interface (capable of inducing acute bradycardia) was demonstrated with lifetimes exceeding three weeks. The design utilizes only commercially-available electrical components and 3D-printed packaging, with the goal of facilitating widespread adoption and accelerating discovery and translation of future bioelectronic therapeutics.
Collapse
Affiliation(s)
- Jason P Wright
- Institute of Bioelectronic Medicine, The Feinstein Institutes for Medical Research, Northwell Health, 350 Community Dr, Manhasset, NY, United States
| | - Ibrahim T Mughrabi
- Institute of Bioelectronic Medicine, The Feinstein Institutes for Medical Research, Northwell Health, 350 Community Dr, Manhasset, NY, United States
| | - Jason Wong
- Institute of Bioelectronic Medicine, The Feinstein Institutes for Medical Research, Northwell Health, 350 Community Dr, Manhasset, NY, United States
| | - Jose Mathew
- Institute of Bioelectronic Medicine, The Feinstein Institutes for Medical Research, Northwell Health, 350 Community Dr, Manhasset, NY, United States
| | - Naveen Jayaprakash
- Institute of Bioelectronic Medicine, The Feinstein Institutes for Medical Research, Northwell Health, 350 Community Dr, Manhasset, NY, United States
| | - Christine Crosfield
- Institute of Bioelectronic Medicine, The Feinstein Institutes for Medical Research, Northwell Health, 350 Community Dr, Manhasset, NY, United States
| | - Eric H Chang
- Institute of Bioelectronic Medicine, The Feinstein Institutes for Medical Research, Northwell Health, 350 Community Dr, Manhasset, NY, United States
| | - Sangeeta S Chavan
- Institute of Bioelectronic Medicine, The Feinstein Institutes for Medical Research, Northwell Health, 350 Community Dr, Manhasset, NY, United States
| | - Kevin J Tracey
- Institute of Bioelectronic Medicine, The Feinstein Institutes for Medical Research, Northwell Health, 350 Community Dr, Manhasset, NY, United States
| | - Valentin A Pavlov
- Institute of Bioelectronic Medicine, The Feinstein Institutes for Medical Research, Northwell Health, 350 Community Dr, Manhasset, NY, United States
| | - Yousef Al-Abed
- Institute of Bioelectronic Medicine, The Feinstein Institutes for Medical Research, Northwell Health, 350 Community Dr, Manhasset, NY, United States
| | - Theodoros P Zanos
- Institute of Bioelectronic Medicine, The Feinstein Institutes for Medical Research, Northwell Health, 350 Community Dr, Manhasset, NY, United States
| | - Stavros Zanos
- Institute of Bioelectronic Medicine, The Feinstein Institutes for Medical Research, Northwell Health, 350 Community Dr, Manhasset, NY, United States
| | - Timir Datta-Chaudhuri
- Institute of Bioelectronic Medicine, The Feinstein Institutes for Medical Research, Northwell Health, 350 Community Dr, Manhasset, NY, United States.
| |
Collapse
|
6
|
Bowles S, Williamson WR, Nettles D, Hickman J, Welle CG. Closed-loop automated reaching apparatus (CLARA) for interrogating complex motor behaviors. J Neural Eng 2021; 18:10.1088/1741-2552/ac1ed1. [PMID: 34407518 PMCID: PMC8699662 DOI: 10.1088/1741-2552/ac1ed1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Accepted: 08/18/2021] [Indexed: 11/11/2022]
Abstract
Objective.Closed-loop neuromodulation technology is a rapidly expanding category of therapeutics for a broad range of indications. Development of these innovative neurological devices requires high-throughput systems for closed-loop stimulation of model organisms, while monitoring physiological signals and complex, naturalistic behaviors. To address this need, we developed CLARA, a closed-loop automated reaching apparatus.Approach.Using breakthroughs in computer vision, CLARA integrates fully-automated, markerless kinematic tracking of multiple features to classify animal behavior and precisely deliver neural stimulation based on behavioral outcomes. CLARA is compatible with advanced neurophysiological tools, enabling the testing of neurostimulation devices and identification of novel neurological biomarkers.Results.The CLARA system tracks unconstrained skilled reach behavior in 3D at 150 Hz without physical markers. The system fully automates trial initiation and pellet delivery and is capable of accurately delivering stimulation in response to trial outcome with short latency. Kinematic data from the CLARA system provided novel insights into the dynamics of reach consistency over the course of learning, suggesting that learning selectively improves reach failures but does not alter the kinematics of successful reaches. Additionally, using the closed-loop capabilities of CLARA, we demonstrate that vagus nerve stimulation (VNS) improves skilled reach performance and increases reach trajectory consistency in healthy animals.Significance.The CLARA system is the first mouse behavior apparatus that uses markerless pose tracking to provide real-time closed-loop stimulation in response to the outcome of an unconstrained motor task. Additionally, we demonstrate that the CLARA system was essential for our investigating the role of closed-loop VNS stimulation on motor performance in healthy animals. This approach has high translational relevance for developing neurostimulation technology based on complex human behavior.
Collapse
Affiliation(s)
- S Bowles
- Neurosurgery, The University of Colorado Anschutz Medical Campus, Aurora, CO 80045, United States of America
- These authors contributed equally
| | - W R Williamson
- NeuroTechnology Center, The University of Colorado Anschutz Medical Campus, Aurora, CO 80045, United States of America
- These authors contributed equally
| | - D Nettles
- Neurosurgery, The University of Colorado Anschutz Medical Campus, Aurora, CO 80045, United States of America
| | - J Hickman
- Neurosurgery, The University of Colorado Anschutz Medical Campus, Aurora, CO 80045, United States of America
| | - C G Welle
- Neurosurgery, The University of Colorado Anschutz Medical Campus, Aurora, CO 80045, United States of America
| |
Collapse
|
7
|
Gibney S, Hicks JM, Robinson A, Jain A, Sanjuan-Alberte P, Rawson FJ. Toward nanobioelectronic medicine: Unlocking new applications using nanotechnology. WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY 2021; 13:e1693. [PMID: 33442962 DOI: 10.1002/wnan.1693] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 11/29/2020] [Accepted: 12/14/2020] [Indexed: 12/11/2022]
Abstract
Bioelectronic medicine aims to interface electronic technology with biological components and design more effective therapeutic and diagnostic tools. Advances in nanotechnology have moved the field forward improving the seamless interaction between biological and electronic components. In the lab many of these nanobioelectronic devices have the potential to improve current treatment approaches, including those for cancer, cardiovascular disorders, and disease underpinned by malfunctions in neuronal electrical communication. While promising, many of these devices and technologies require further development before they can be successfully applied in a clinical setting. Here, we highlight recent work which is close to achieving this goal, including discussion of nanoparticles, carbon nanotubes, and nanowires for medical applications. We also look forward toward the next decade to determine how current developments in nanotechnology could shape the growing field of bioelectronic medicine. This article is categorized under: Therapeutic Approaches and Drug Discovery > Emerging Technologies Nanotechnology Approaches to Biology > Nanoscale Systems in Biology Diagnostic Tools > Biosensing.
Collapse
Affiliation(s)
- Steven Gibney
- Division of Regenerative Medicine and Cellular Therapies, Biodiscovery Institute,School of Pharmacy, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Jacqueline M Hicks
- Division of Regenerative Medicine and Cellular Therapies, Biodiscovery Institute,School of Pharmacy, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Andie Robinson
- Division of Regenerative Medicine and Cellular Therapies, Biodiscovery Institute,School of Pharmacy, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Akhil Jain
- Division of Regenerative Medicine and Cellular Therapies, Biodiscovery Institute,School of Pharmacy, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Paola Sanjuan-Alberte
- Division of Regenerative Medicine and Cellular Therapies, Biodiscovery Institute,School of Pharmacy, University of Nottingham, University Park, Nottingham NG7 2RD, UK.,Department of Bioengineering and iBB-Institute for Bioengineering and Biosciences, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal
| | - Frankie J Rawson
- Division of Regenerative Medicine and Cellular Therapies, Biodiscovery Institute,School of Pharmacy, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| |
Collapse
|
8
|
Bhagat N, King K, Ramdeo R, Stein A, Bouton C. Determining grasp selection from arm trajectories via deep learning to enable functional hand movement in tetraplegia. Bioelectron Med 2020; 6:17. [PMID: 32864392 PMCID: PMC7449026 DOI: 10.1186/s42234-020-00053-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2020] [Accepted: 07/21/2020] [Indexed: 11/10/2022] Open
Abstract
Background Cervical spinal cord injury severely affects grasping ability of its survivors. Fortunately, many individuals with tetraplegia retain residual arm movements that allow them to reach for objects. We propose a wearable technology that utilizes arm movement trajectory information and deep learning methods to determine grasp selection. Furthermore, we combined this approach with neuromuscular stimulation to determine if self-driven functional hand movement could be enabled in spinal cord injury participants. Methods Two cervical SCI participants performed arbitrary and natural reaching movements toward target objects in three-dimensional space, which were recorded using an inertial sensor worn on their wrist. Time series classifiers were trained to recognize the trajectories using either a Dynamic Time Warping (DTW) algorithm or a Long Short-Term Memory (LSTM) recurrent neural network. As an initial proof-of-concept, we demonstrate real-time classification of the arbitrary movements using DTW only (due to its implementation simplicity), which when used in combination with a high density neuromuscular stimulation sleeve with textile electrodes, enabled participants to perform functional grasping. Results Participants were able to consistently perform arbitrary two-dimensional and three-dimensional arm movements which could be classified with high accuracy. Furthermore, it was found that natural reaching trajectories for two different target objects (requiring two different grasp types) were distinct and also discriminable with high accuracy. In offline comparisons, LSTM (mean accuracies 99%) performed significantly better than DTW (mean accuracies 86 and 83%) for both arbitrary and natural reaching movements, respectively. Type I and II errors occurred more frequently for DTW (up to 60 and 15%, respectively), whereas it stayed under 5% for LSTM. Also, DTW achieved online accuracy of 79%. Conclusions We demonstrate the feasibility of utilizing arm trajectory information to determine grasp selection using a wearable inertial sensor along with DTW and deep learning methods. Importantly, this technology can be successfully used to control neuromuscular stimulation and restore functional independence to individuals living with paralysis. Trial registration NCT, NCT03385005. Registered September 26, 2017.
Collapse
Affiliation(s)
- Nikunj Bhagat
- Feinstein Institutes for Medical Research at Northwell Health, Manhasset, NY USA.,Institute for Bioelectronic Medicine, Feinstein Institutes for Medical Research, Manhasset, NY USA
| | - Kevin King
- Feinstein Institutes for Medical Research at Northwell Health, Manhasset, NY USA.,Institute for Bioelectronic Medicine, Feinstein Institutes for Medical Research, Manhasset, NY USA
| | - Richard Ramdeo
- Feinstein Institutes for Medical Research at Northwell Health, Manhasset, NY USA.,Institute for Bioelectronic Medicine, Feinstein Institutes for Medical Research, Manhasset, NY USA
| | - Adam Stein
- Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY USA
| | - Chad Bouton
- Feinstein Institutes for Medical Research at Northwell Health, Manhasset, NY USA.,Institute for Bioelectronic Medicine, Feinstein Institutes for Medical Research, Manhasset, NY USA.,Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY USA
| |
Collapse
|