1
|
Massey PA, Dudoussat E, Montgomery C, Scalisi W, McBride H, Rutz R, Solitro GF. Suture Tying Force for Cut-Out during Radial Meniscus Tear Repair: A Biomechanical Evaluation of Failure Loads during the Knot-Tying Process. Cartilage 2024:19476035241284827. [PMID: 39344014 PMCID: PMC11556578 DOI: 10.1177/19476035241284827] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/01/2024] Open
Abstract
OBJECTIVE The purpose of the study was to determine average tensile forces resulting in suture failure while tying a knot during repair of complete radial meniscus tears and to compare the failure tensile force based on meniscus tissue location: the peripheral (red-red) versus inner (white-white). DESIGN This study was designed as a cadaveric biomechanical study using 24 menisci harvested from fresh frozen cadaveric knees with midbody radial tears. Tears were repaired using 2-0 nonabsorbable suture in both the inner meniscus and the peripheral meniscus. A force gauge was used to measure the tension of a surgeon's knot until failure of either the suture or the meniscus tissue. Statistical analysis was performed comparing suture failure tensile forces between inner and peripheral sutures using 2-sample t test. RESULTS Suture repairs primarily failed due to meniscal tissue cut-out after suture tensioning (96%). There was no statistical difference in failure mode between medial and lateral meniscus for both the inner (100% cut-out) and the peripheral (92% cut-out; P = 0.703) sutures. The peripheral sutures failed as significantly higher loads (54 ± 26 N) than the inner sutures (36 ± 11 N, P = 0.006). The peripheral meniscus tissue tolerated significantly higher tension at failure (36 ± 7 N) than the inner meniscus (26 ± 7 N, P < 0.001). CONCLUSION When tying parallel sutures to repair a radial meniscus tear, suture tensile forces above 30 N may tear through meniscus tissue. Surgeons should not use suture tying forces above 30 N when repairing radial meniscus tears with parallel sutures. The peripheral meniscus can withstand higher knot-tying forces than the inner meniscus, so surgeons should consider tying the peripheral suture before the inner suture.
Collapse
Affiliation(s)
- Patrick A. Massey
- Department of Orthopaedic Surgery, Louisiana State University Health Sciences Center Shreveport, Shreveport, LA, USA
| | - Edwin Dudoussat
- Department of Orthopaedic Surgery, Louisiana State University Health Sciences Center Shreveport, Shreveport, LA, USA
| | - Carver Montgomery
- Department of Orthopaedic Surgery, Louisiana State University Health Sciences Center Shreveport, Shreveport, LA, USA
| | - Wayne Scalisi
- Department of Orthopaedic Surgery, Louisiana State University Health Sciences Center Shreveport, Shreveport, LA, USA
| | - Hayden McBride
- Department of Orthopaedic Surgery, Louisiana State University Health Sciences Center Shreveport, Shreveport, LA, USA
| | - Robert Rutz
- Department of Orthopaedic Surgery, Louisiana State University Health Sciences Center Shreveport, Shreveport, LA, USA
| | - Giovanni F. Solitro
- Department of Orthopaedic Surgery, Louisiana State University Health Sciences Center Shreveport, Shreveport, LA, USA
| |
Collapse
|
2
|
Perez AR, Coladonato C, Muchintala R, Christopher N, Matthews J, Tjoumakaris FP, Freedman KB. A systematic review of the biomechanical properties of suture materials used in orthopaedics. J Orthop 2024; 51:122-129. [PMID: 38371350 PMCID: PMC10867560 DOI: 10.1016/j.jor.2024.01.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Revised: 01/15/2024] [Accepted: 01/21/2024] [Indexed: 02/20/2024] Open
Abstract
Background Soft tissue injuries are frequently repaired using various suture material. The ideal suture should have the biomechanical properties of low displacement, high maximum load to failure, and high stiffness to avoid deformation. Since tendon healing occurs over a period of months, it is important for the surgeon to select the proper suture with certain biomechanical properties. Therefore, the purpose of this study is to qualitative summarize the published literature on biomechanical properties of different suture materials used in orthopaedic procedures. Methods Following PRISMA guidelines, PubMed and Cochrane databases were queried for original articles containing "biomechanic(s)" and "suture" keywords. Following screening for inclusion and exclusion, final articles were reviewed for relevant data and collected for qualitative analysis. Data collected from each study included the tissue type repaired, suture material, and biomechanical properties, such as elongation, maximum load to failure, stiffness, and method of failure. Results 17 articles met final inclusion criteria. Two studies found No.2 Fiberwire™ to have the lowest elongation and 4 studies found No. 2 Ultrabraid™ to have the greatest. 12 studies reported Maximum load to failure was highest in No. 2 Fiberwire™, No. 2 Ultrabraid™, and FiberTape™ while No. 2 Ethibond ™ had the lowest in 5 studies. 3 of the 5 studies that evaluated No. 2 Fiberwire™ found it to have the highest stiffness. No. 2 Ethibond™, No. 2 Orthocord™, and No. 2 PDS™ were reported as the least stiff sutures in 2 studies each. Conclusion Fiberwire™, FiberTape™, and Ultrabraid™ demonstrated the highest load to failure while Ethibond™ consistently was the weakest. Fiberwire™ was found to have the lowest elongation while Ultrabraid™ had the highest. Fiberwire™ was also noted to be the stiffest while PDS, Ethibond™, and Orthocord™ were found to be the least stiff. Final treatment decisions on which suture to utilize to optimize repair integrity and healing are complex, and rarely solely dependent upon the biomechanical properties of the materials used. Level of evidence Systematic Review, Level IV.
Collapse
Affiliation(s)
| | | | | | | | - John Matthews
- Rothman Orthopaedic Institute, Philadelphia, PA, USA
| | | | | |
Collapse
|
3
|
Rocha de Faria JL, Santos APG, Pavão DM, Radulski M, Leal AC, More ADO, Mozella ADP, Guimarães JAM, LaPrade RF, Roesler CRDM, Salim R. Continuous Vertical Inside-Out Versus Traditional Vertical Inside-Out Meniscal Repair: A Biomechanical Comparison. Orthop J Sports Med 2023; 11:23259671231209951. [PMID: 38021309 PMCID: PMC10644761 DOI: 10.1177/23259671231209951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Accepted: 06/02/2023] [Indexed: 12/01/2023] Open
Abstract
Background Biomechanical assessment of meniscal repairs is essential for evaluating different meniscal suturing methods and techniques. The continuous meniscal suture technique is a newer method of meniscal repair that may have biomechanical differences compared with traditional techniques. Purpose To evaluate the displacement, stiffness after cyclical loading, and load to failure for a continuous vertical inside-out meniscal suture versus a traditional vertical inside-out meniscal suture in a porcine medial meniscus. Study Design Controlled laboratory study. Methods A total of 28 porcine knees were acquired and divided into 2 test groups of 14 medial meniscus each. A 2.0-cm longitudinal red-white zone cut was made in the body of the medial meniscus for each knee. The continuous suture (CS) group received 4 vertical stitches performed with a continuous vertical meniscal suture technique, and the inside-out suture (IO) group received a traditional vertical suture with 4 stitches. Two traction tapes were passed between the sutures and positioned in the biomechanical testing fixture device. Each specimen underwent load-to-failure testing at 5 mm/s, and displacement, system stiffness, and maximum load to failure were compared between the groups. Results The displacement after the cyclic test was 0.53 ± 0.12 and 0.48 ± 0.07 mm for the CS and IO groups, respectively. There was no significant difference between the groups (P = .2792). The stiffness at the ultimate load testing was 36.3 ± 1.9 and 35.3 ± 2.4 N/mm for groups CS and IO, respectively, with no significant difference between the groups (P = .2557). In the load-to-failure test, the ultimate load was 218.2 ± 63.9 and 238.3 ± 71.3 N in the CS and IO groups, respectively, with no significant group differences (P = .3062). Conclusion A continuous vertical meniscal suture created a configuration for treating longitudinal meniscal lesions that was beneficial and biomechanically similar to a traditional vertical suture technique. Clinical Relevance The study findings indicate that use of the continuous vertical inside-out meniscal suture technique is a possible therapeutic option.
Collapse
Affiliation(s)
- José Leonardo Rocha de Faria
- Knee Surgery Center, National Institute of Traumatology and Orthopedics (INTO), Rio de Janeiro, Brazil
- School of Medicine from University of São Paulo (USP), Ribeirão Preto, São Paulo, Brazil
| | - Arthur Paiva Grimaldi Santos
- Biomechanical Engineering Laboratory of Federal University of Santa Catarina, Florianópolis, Santa Catarina, Brazil
| | - Douglas Mello Pavão
- Knee Surgery Center, National Institute of Traumatology and Orthopedics (INTO), Rio de Janeiro, Brazil
- School of Medicine from University of São Paulo (USP), Ribeirão Preto, São Paulo, Brazil
| | - Mariana Radulski
- Medical School of Federal University of Santa Catarina, Florianópolis, Santa Catarina, Brazil
| | - Ana Carolina Leal
- Research Division, National Institute of Traumatology and Orthopedics (INTO), Rio de Janeiro, Brazil
| | - Ari Digiácomo Ocampo More
- Biomechanical Engineering Laboratory of Federal University of Santa Catarina, Florianópolis, Santa Catarina, Brazil
- Medical School of Federal University of Santa Catarina, Florianópolis, Santa Catarina, Brazil
| | - Alan de Paula Mozella
- Knee Surgery Center, National Institute of Traumatology and Orthopedics (INTO), Rio de Janeiro, Brazil
- School of Medicine from University of São Paulo (USP), Ribeirão Preto, São Paulo, Brazil
| | | | - Robert F LaPrade
- Twin Cities Orthopaedics, Edina, Minnesota, USA
- University of Minnesota Medical School, Minneapolis, Minnesota, USA
| | | | - Rodrigo Salim
- School of Medicine from University of São Paulo (USP), Ribeirão Preto, São Paulo, Brazil
| |
Collapse
|
4
|
Kim JS, Lee MK, Choi MY, Kong DH, Ha JK, Kim JG, Chung KS. Rehabilitation after Repair of Medial Meniscus Posterior Root Tears: A Systematic Review of the Literature. Clin Orthop Surg 2023; 15:740-751. [PMID: 37811518 PMCID: PMC10551690 DOI: 10.4055/cios21231] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2021] [Revised: 07/19/2022] [Accepted: 07/25/2022] [Indexed: 10/10/2023] Open
Abstract
Background There is no consensus established on postoperative rehabilitation after medial meniscus posterior root tear (MMPRT) repair, including when and how physicians can apply range of motion (ROM) exercise, weight-bearing (WB), brace use, and return to sports (RTS). The purpose of this study was to systematically review the literature on postoperative rehabilitation characteristics of MMPRT repair regarding ROM, WB, brace use, and RTS. Methods A literature search was performed using the Medline/PubMed, Cochrane Central Register of Controlled Trials, and Embase databases. The inclusion criteria were English language, human clinical studies, and studies describing rehabilitation protocols after MMPRT repair such as ROM, WB, brace use, and RTS. Abstracts, case reports, cohort studies, controlled laboratory studies, human cadaveric or animal studies, systematic reviews, and meta-analyses were excluded. Results Thirteen studies were included. Of the 12 ROM studies, ROM was started immediately within 1 or 2 days after operation in 6 studies and after 2 to 3 weeks of knee immobilization in the rest. Of the 13 WB studies, partial weight-bearing was initiated 1 to 4 weeks after operation in 8 studies and 6 weeks in the rest. Of the 9 brace studies, patients were immobilized by a splint for 2 weeks in 3 studies, and in the rest, a brace with full extension was applied for 3 to 6 weeks after several days of splint application. Of the 7 RTS studies, RTS was allowed at 6 months in 6 studies and 5 to 7 months in 1 study. Conclusions This systematic review revealed conservative rehabilitation protocols were more widely adapted as ROM and WB were restricted at certain degrees during postoperative periods in most protocols analyzed. However, it is impossible to identify a consensus on rehabilitation protocols as the protocols analyzed in this review were distinct each other and heterogeneous. In the future, a well-designed comparative study among different rehabilitation protocols is essential to establish a consensus.
Collapse
Affiliation(s)
- Jin Seong Kim
- Department of Orthopedic Surgery and Sports Medical Center, Sports Medical Research Institute, Seoul Paik Hospital, College of Medicine, Inje University, Seoul, Korea
| | - Min Ki Lee
- Department of Orthopedic Surgery and Sports Medical Center, Sports Medical Research Institute, Seoul Paik Hospital, College of Medicine, Inje University, Seoul, Korea
| | - Moon Young Choi
- Department of Orthopedic Surgery and Sports Medical Center, Sports Medical Research Institute, Seoul Paik Hospital, College of Medicine, Inje University, Seoul, Korea
| | - Doo Hwan Kong
- Department of Orthopedic Surgery and Sports Medical Center, Sports Medical Research Institute, Seoul Paik Hospital, College of Medicine, Inje University, Seoul, Korea
| | - Jeong Ku Ha
- Department of Orthopedic Surgery and Sports Medical Center, Sports Medical Research Institute, Seoul Paik Hospital, College of Medicine, Inje University, Seoul, Korea
| | - Jin Goo Kim
- Department of Orthopaedic Surgery, Hanyang University Myongji Hospital, Goyang, Korea
| | - Kyu Sung Chung
- Department of Orthopedic Surgery and Sports Medical Center, Sports Medical Research Institute, Seoul Paik Hospital, College of Medicine, Inje University, Seoul, Korea
| |
Collapse
|
5
|
Hiranaka T, Furumatsu T, Okazaki Y, Kintaka K, Kamatsuki Y, Zhang X, Xue H, Hamada M, Ozaki T. Clinical evaluation of suture materials for transtibial pullout repair of medial meniscus posterior root tear. Knee Surg Relat Res 2022; 34:39. [PMID: 36209256 PMCID: PMC9548199 DOI: 10.1186/s43019-022-00167-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Accepted: 09/25/2022] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND There are no recommendations for specific suture materials in transtibial pullout repair of medial meniscus posterior root tears. This study aimed to evaluate the clinical outcomes of transtibial pullout repair of medial meniscus posterior root tears using ultrahigh-molecular-weight polyethylene sutures and suture tape. METHODS We retrospectively reviewed the data of 36 patients (27 women and 9 men, mean age 64.1 years) who had undergone transtibial pullout repair of medial meniscus posterior root tears between November 2018 and December 2019. Two groups of 18 patients each received either two different cord-like sutures or suture tape. Clinical parameters were assessed preoperatively and on second-look arthroscopy (mean postoperative period 12 months). The meniscal healing status was assessed using a previously published scoring system (ranging from 0 to 10), and the incidence rate of suture cut-out was assessed on second-look arthroscopy. RESULTS All clinical scores significantly improved in both groups, with no significant between-group differences on second-look arthroscopy. The arthroscopic meniscal healing scores significantly differed between sutures (mean 6.7 points) and suture tape (mean 7.4 points; p = 0.044). No significant between-group difference in the suture cut-out rate was observed. CONCLUSIONS This study found no significant differences in the clinical outcomes between ultrahigh-molecular-weight polyethylene sutures and suture tape. Favorable clinical outcomes were obtained using both types of suture; however, the usefulness of suture tape appears to be limited.
Collapse
Affiliation(s)
- Takaaki Hiranaka
- grid.412342.20000 0004 0631 9477Department of Orthopaedic Surgery, Okayama University Hospital, 2-5-1 Shikatacho, Kitaku, Okayama, 700-8558 Japan ,Department of Orthopaedic Surgery, Ako Central Hospital, 52-6 Soumoncho, Ako, Hyogo 678-0241 Japan
| | - Takayuki Furumatsu
- grid.412342.20000 0004 0631 9477Department of Orthopaedic Surgery, Okayama University Hospital, 2-5-1 Shikatacho, Kitaku, Okayama, 700-8558 Japan ,Department of Orthopaedic Surgery, Ako Central Hospital, 52-6 Soumoncho, Ako, Hyogo 678-0241 Japan ,grid.261356.50000 0001 1302 4472Department of Orthopaedic Surgery, Okayama University Graduate School, 2-5-1 Shikatacho, Kitaku, Okayama, 700-8558 Japan
| | - Yuki Okazaki
- grid.412342.20000 0004 0631 9477Department of Orthopaedic Surgery, Okayama University Hospital, 2-5-1 Shikatacho, Kitaku, Okayama, 700-8558 Japan
| | - Keisuke Kintaka
- grid.412342.20000 0004 0631 9477Department of Orthopaedic Surgery, Okayama University Hospital, 2-5-1 Shikatacho, Kitaku, Okayama, 700-8558 Japan
| | - Yusuke Kamatsuki
- grid.412342.20000 0004 0631 9477Department of Orthopaedic Surgery, Okayama University Hospital, 2-5-1 Shikatacho, Kitaku, Okayama, 700-8558 Japan
| | - Ximing Zhang
- grid.412342.20000 0004 0631 9477Department of Orthopaedic Surgery, Okayama University Hospital, 2-5-1 Shikatacho, Kitaku, Okayama, 700-8558 Japan
| | - Haowei Xue
- grid.412342.20000 0004 0631 9477Department of Orthopaedic Surgery, Okayama University Hospital, 2-5-1 Shikatacho, Kitaku, Okayama, 700-8558 Japan
| | - Masanori Hamada
- grid.412342.20000 0004 0631 9477Department of Orthopaedic Surgery, Okayama University Hospital, 2-5-1 Shikatacho, Kitaku, Okayama, 700-8558 Japan
| | - Toshifumi Ozaki
- grid.412342.20000 0004 0631 9477Department of Orthopaedic Surgery, Okayama University Hospital, 2-5-1 Shikatacho, Kitaku, Okayama, 700-8558 Japan
| |
Collapse
|
6
|
Okazaki Y, Furumatsu T, Hiranaka T, Zhang X, Kintaka K, Higashihara N, Tamura M, Kodama Y, Kamatsuki Y, Ozaki T. Arthroscopic Meniscal Healing following Medial Meniscus Posterior Root Repair: A Comparison between Two Suture Materials. J Knee Surg 2022. [PMID: 35798342 DOI: 10.1055/s-0042-1750047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Recently, transtibial pullout repair of the medial meniscus (MM) posterior root tear (PRT) has become widely accepted and provides satisfactory clinical outcomes. Widening after cyclic loading or ultimate failure load using different suture materials and configurations has been studied. However, no study has compared the clinical outcomes using different suture materials. This study aimed to evaluate the clinical outcomes after performing MMPRT pullout repair using different suture materials. We hypothesized that better clinical outcomes would be achieved using ultra-high molecular weight polyethylene (UHMWPE) tape compared with a normal polyester suture. Thirty-seven patients who underwent MM posterior root repair between November 2019 and May 2020 were retrospectively investigated. Pullout repair was performed using a hollow no. 0 polyester suture (n = 14) and UHMWPE tape (n = 23). Clinical outcomes were assessed preoperatively and at 1 year postoperatively, using the Lysholm knee score, Knee Injury and Osteoarthritis Outcome Score, and visual analogue scale (VAS) pain score. The meniscal healing status was assessed using an arthroscopic scoring system (range: 0-10). All clinical scores were improved significantly in both groups. However, significantly higher meniscal healing scores and decreased VAS pain scores were observed in the UHMWPE group (7.3 ± 0.9 and 7.7 ± 11.3, respectively) than in the polyester group (5.6 ± 2.1 and 18.4 ± 18.6, respectively; p < 0.01). Suture cut-out and loss of the root continuity were observed in some cases (three cases [21.4%] in the polyester suture group and one case [4.3%] in the UHMWPE tape group). Both suture materials led to satisfactory clinical outcomes at 1 year postoperatively, whereas the UHMWPE tape was useful for obtaining good meniscal healing and decreasing the VAS pain score.
Collapse
Affiliation(s)
- Yuki Okazaki
- Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Kita-ku, Okayama, Japan
| | - Takayuki Furumatsu
- Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Kita-ku, Okayama, Japan
| | - Takaaki Hiranaka
- Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Kita-ku, Okayama, Japan
| | - Ximing Zhang
- Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Kita-ku, Okayama, Japan
| | - Keisuke Kintaka
- Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Kita-ku, Okayama, Japan
| | - Naohiro Higashihara
- Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Kita-ku, Okayama, Japan
| | - Masanori Tamura
- Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Kita-ku, Okayama, Japan
| | - Yuya Kodama
- Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Kita-ku, Okayama, Japan
| | - Yusuke Kamatsuki
- Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Kita-ku, Okayama, Japan
| | - Toshifumi Ozaki
- Department of Orthopaedic Surgery, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Kita-ku, Okayama, Japan
| |
Collapse
|
7
|
Ernstbrunner L, Rupasinghe HS, Almond M, Jo OI, Zbeda RM, Oppy A, Treseder T, Pullen C, Ek ET, Ackland DC. A new all-suture tension band tape fixation technique for simple olecranon fractures versus conventional tension band wire fixation: a comparative biomechanics study. J Shoulder Elbow Surg 2022; 31:1376-1384. [PMID: 35167913 DOI: 10.1016/j.jse.2022.01.130] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Accepted: 01/12/2022] [Indexed: 02/01/2023]
Abstract
HYPOTHESIS Simple transverse or short oblique olecranon fractures without articular comminution are classified as Mayo type IIA fractures and are typically treated with a tension band wire construct. Because of the high reoperation rates, frequently because of prominent hardware, all-suture tension band constructs have been introduced. It was the purpose to compare the biomechanical performance of conventional tension band wire fixation with a new all-suture tension band tape fixation for simple olecranon fractures. METHODS Mayo type IIA olecranon fractures were created in 20 cadaveric elbows from 10 donors. One elbow of each donor was randomly assigned to the tension band wire technique (group TBW) or tension band tape (Arthrex, 1.3-mm SutureTape) technique (group TBT). Both groups were cyclically loaded with 500 N over 500 cycles, after which a uniaxial displacement was performed to evaluate load to failure. Data were analyzed for gap formation after cyclic loading, construct stiffness, and ultimate load to failure, where failure was defined as fracture gap formation greater than 4.0 mm. RESULTS There was no significant difference in gap formation after 500 cycles between the TBW (1.8 mm ± 1.3 mm) and the TBT (1.9 mm ± 1.1 mm) groups (P = .854). The TBT showed a tendency toward greater construct stiffness compared with the TBW construct (mean difference: 142 N/mm; P = .053). Ultimate load to failure was not significantly different comparing both groups (TBW: 1138 N ± 286 N vs. TBT: 1126 N ± 272 N; P = .928). In both groups, all repairs failed because of >4.0-mm gap formation at the fracture site and none because of tension band construct breakage. CONCLUSIONS Our study shows that the TBT technique produces equivalent or superior biomechanical performance to the TBW for simple olecranon fractures. The TBT approach reduces the risk of hardware prominence and as a result mitigates against the need for hardware removal. The TBT technique offers a clinically viable alternative to TBW.
Collapse
Affiliation(s)
- Lukas Ernstbrunner
- Upper Limb Surgery, Melbourne Orthopaedic Group, Windsor, VIC, Australia; Hand and Wrist Biomechanics Laboratory (HWBL), O'Brien Institute/St. Vincent's Institute, Melbourne, VIC, Australia; Department of Orthopaedic Surgery, Royal Melbourne Hospital, Parkville, VIC, Australia; Department of Biomedical Engineering, University of Melbourne, Parkville, VIC, Australia.
| | | | - Mitchell Almond
- Department of Biomedical Engineering, University of Melbourne, Parkville, VIC, Australia
| | - Olivia I Jo
- Department of Orthopaedic Surgery, Royal Melbourne Hospital, Parkville, VIC, Australia
| | - Robert M Zbeda
- Upper Limb Surgery, Melbourne Orthopaedic Group, Windsor, VIC, Australia
| | - Andrew Oppy
- Department of Orthopaedic Surgery, Royal Melbourne Hospital, Parkville, VIC, Australia
| | - Thomas Treseder
- Department of Orthopaedic Surgery, Royal Melbourne Hospital, Parkville, VIC, Australia
| | - Christopher Pullen
- Department of Orthopaedic Surgery, Royal Melbourne Hospital, Parkville, VIC, Australia
| | - Eugene T Ek
- Upper Limb Surgery, Melbourne Orthopaedic Group, Windsor, VIC, Australia; Hand and Wrist Biomechanics Laboratory (HWBL), O'Brien Institute/St. Vincent's Institute, Melbourne, VIC, Australia
| | - David C Ackland
- Department of Biomedical Engineering, University of Melbourne, Parkville, VIC, Australia
| |
Collapse
|
8
|
Abstract
Meniscal lesions often occur in association with anterior cruciate ligament (ACL) tears at the moment of the injury or, secondarily, as a consequence of knee instability. Both ACL and meniscus lesions are associated with a higher risk of osteoarthritis. Adequate treatment of these lesions reduces the rate of degenerative changes in the affected knee. Meniscal tears should be addressed concomitantly with ACL reconstruction and the treatment must be oriented towards preserving the meniscal tissue anytime this is possible. Several options for approaching a meniscus tear are available. The meniscal suture should always be considered, and, if possible, meniscectomy should be the last choice. “Masterly neglect” is a valuable option in selected cases.
Collapse
|
9
|
Chung KS, Ha JK, Ra HJ, Kim JG. Preoperative varus alignment and postoperative meniscus extrusion are the main long-term predictive factors of clinical failure of meniscal root repair. Knee Surg Sports Traumatol Arthrosc 2021; 29:4122-4130. [PMID: 33730189 DOI: 10.1007/s00167-020-06405-7] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/30/2020] [Accepted: 12/07/2020] [Indexed: 11/25/2022]
Abstract
PURPOSE No studies have been conducted to determine long-term predictors of clinical failure after surgical root repair. This study identified long-term prognostic factors of clinical failure after pull-out repair of medial meniscus posterior root tears (MMPRTs) at a minimum of 10 year follow-up. METHODS A total of 37 patients who underwent MMPRT pull-out repair and had been observed for more than 10 years were recruited for this study. The mean follow-up period was 125.9 ± 21.2 months. Clinical failure of the procedures was defined as conversion to total knee arthroplasty (TKA). Participants were categorized into two groups: non-failure and failure groups. Various factors, including demographic features and radiologic findings, were analyzed and compared between the two groups. Meniscus extrusion was assessed at coronal magnetic resonance imaging preoperatively and 1 year postoperatively. Independent risk factors were determined by univariate analysis and logistic regression analysis. To determine the cut-off value for risk factors, the receiver-operating characteristic curve analysis was performed. RESULTS In total, eight patients (22%) were converted to TKA during the follow-up period. With univariate analysis, statistically significant differences between two groups were observed in mechanical varus alignment (P = 0.018), rate of the number of patient with more meniscal extrusion values after surgery (P = 0.024), and the difference between the preoperative and 1-year postoperative value of meniscus extrusion (mm) (P = 0.010). In a logistic analysis, OR of mechanical varus alignment and differences in meniscus extrusion value before and 1 year after surgery was 1.5 (P = 0.048) and 3.7 (P = 0.034). The cut-off values of mechanical varus alignment and differences in meniscus extrusion values were 5 degrees and 0.7 mm. CONCLUSION Clinically, preoperative varus alignment and increased meniscal extrusion after surgery were found to be predictive for a clinical failure after meniscal root repair in a long-term perspective. Thus, these negative prognostic factors should be taken into consideration for performing root repair in MMPRTs. LEVEL OF EVIDENCE Level III.
Collapse
Affiliation(s)
- Kyu Sung Chung
- Department of Orthopedic Surgery and Sports Medical Center and Sports Medical Research Institute, Seoul Paik Hospital, College of Medicine, Inje University, Seoul, Korea
| | - Jeong Ku Ha
- Department of Orthopedic Surgery and Sports Medical Center and Sports Medical Research Institute, Seoul Paik Hospital, College of Medicine, Inje University, Seoul, Korea
| | - Ho Jong Ra
- Department of Orthopedic Surgery, Gangneung Asan Hospital, College of Medicine, Ulsan University, Gangneung, Korea
| | - Jin Goo Kim
- Department of Orthopedic Surgery and Sports Center, Myong-Ji Hospital, 55, Hwasu-ro 14 beon-gil, Deogyang-gu, Goyang-si, Seoul, 10475, Gyeonggi-do, Korea.
| |
Collapse
|
10
|
Chung KS, Lee MK, Kim JH, Kim JG, Ha JK. An increasing trend of the number of meniscus allograft transplantation in Korea. Knee Surg Sports Traumatol Arthrosc 2021; 29:4131-4137. [PMID: 33638685 DOI: 10.1007/s00167-021-06441-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Accepted: 01/11/2021] [Indexed: 10/22/2022]
Abstract
PURPOSE Meniscus allograft transplantation (MAT) can be performed to treat symptomatic patients with meniscus-deficient knees. However, the current epidemiologic status of MAT is unknown in many countries, including Korea. This study aimed to investigate the national trends of MAT in Korea which covers MAT procedures by the Korean national health insurance system. METHODS Information from the national database was acquired through the Korean Health Insurance Review and Assessment Service (HIRA) from 2010 to 2017. All patients encoded as MAT were included. The total number of MATs and their incidence per 100,000 persons were determined, and the results were stratified by age and sex. RESULTS The total number of MATs and their incidence per 100,000 persons per year were 369 and 0.77, respectively, in 2010, which increased to 826 and 1.72, respectively, in 2017. The number of MATs increased by 124% over 8 years. The peaks for the total number of MATs and their incidence were seen in patients in their 20 s in 2010, but in 2017, the peaks were observed in patients who were in their 40 s. MAT was performed more frequently in males (61%) than in females (39%) over the study period. CONCLUSION The total number of MATs and their incidence had increased by 124% between 2010 and 2017. The peak treatment age range for MAT changed from 20 years of age in 2010 to 40 years of age in 2017, and MAT was performed more frequently in males than in females. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- Kyu Sung Chung
- Department of Orthopaedic Surgery, Sports Medical Center and Sports Medical Research Institute, College of Medicine, Seoul Paik Hospital, Inje University, 9, Mareunnae-ro, Jung-gu, Seoul, Republic of Korea
| | - Min Ki Lee
- Department of Orthopaedic Surgery, Sports Medical Center and Sports Medical Research Institute, College of Medicine, Seoul Paik Hospital, Inje University, 9, Mareunnae-ro, Jung-gu, Seoul, Republic of Korea
| | - Jung Hoon Kim
- Sports and Exercise Medicine Lab, Korea Maritime and Ocean University, Busan, Republic of Korea
| | - Jin Goo Kim
- Department of Orthopedic Surgery and Sports Center, Myong-Ji Hospital, Seoul, South Korea
| | - Jeong Ku Ha
- Department of Orthopaedic Surgery, Sports Medical Center and Sports Medical Research Institute, College of Medicine, Seoul Paik Hospital, Inje University, 9, Mareunnae-ro, Jung-gu, Seoul, Republic of Korea.
| |
Collapse
|