1
|
Gong Y, Barretto FX, Tsong Y, Mousa Y, Ren K, Kozak D, Shen M, Hu M, Zhao L. Development of Quantitative Comparative Approaches to Support Complex Generic Drug Development. AAPS J 2024; 26:15. [PMID: 38267593 DOI: 10.1208/s12248-024-00885-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Accepted: 12/20/2023] [Indexed: 01/26/2024] Open
Abstract
On October 27-28, 2022, the US Food and Drug Administration (FDA) and the Center for Research on Complex Generics (CRCG) hosted a virtual public workshop titled "Best Practices for Utilizing Modeling Approaches to Support Generic Product Development." This report summarizes the presentations and panel discussions for a session titled "Development of Quantitative Comparative Approaches to Support Complex Generic Drug Development." This session featured speakers and panelists from both the generic industry and the FDA who described applications of advanced quantitative approaches for generic drug development and regulatory assessment within three main topics of interest: (1) API sameness assessment for complex generics, (2) particle size distribution assessment, and (3) dissolution profile similarity comparison. The key takeaways were that the analysis of complex data poses significant challenges to the application of conventional statistical bioequivalence methods, and there are various opportunities for using data analytics approaches for developing and applying suitable equivalence assessment method.
Collapse
Affiliation(s)
- Yuqing Gong
- Division of Quantitative Methods and Modeling, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, Maryland, 20993, USA
| | | | - Yi Tsong
- Division of Biometrics VI, Office of Biostatistics, Office of Translational Sciences, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, MD, USA
| | - Youssef Mousa
- Division of Quantitative Methods and Modeling, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, Maryland, 20993, USA
| | - Ke Ren
- Division of Bioequivalence III, Office of Bioequivalence, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, MD, USA
| | - Darby Kozak
- Division of Therapeutic Performance I, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Meiyu Shen
- Division of Biometrics VI, Office of Biostatistics, Office of Translational Sciences, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, MD, USA
| | - Meng Hu
- Division of Quantitative Methods and Modeling, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, Maryland, 20993, USA.
| | - Liang Zhao
- Division of Quantitative Methods and Modeling, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, Maryland, 20993, USA
| |
Collapse
|
2
|
A review of upper airway physiology relevant to the delivery and deposition of inhalation aerosols. Adv Drug Deliv Rev 2022; 191:114530. [PMID: 36152685 DOI: 10.1016/j.addr.2022.114530] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2022] [Revised: 08/07/2022] [Accepted: 09/01/2022] [Indexed: 01/24/2023]
Abstract
Developing effective oral inhaled drug delivery treatment strategies for respiratory diseases necessitates a thorough knowledge of the respiratory system physiology, such as the differences in the airway channel's structure and geometry in health and diseases, their surface properties, and mechanisms that maintain their patency. While respiratory diseases, such as chronic obstructive pulmonary disease (COPD) and asthma and their implications on the lower airways have been the core focus of most of the current research, the role of the upper airway in these diseases is less known, especially in the context of inhaled drug delivery. This is despite the fact that the upper airway is the passageway for inhaled drugs to be delivered to the lower airways, and their replicas are indispensable in current standards, such as the cascade impactor experiments for testing inhaled drug delivery technology. This review provides an overview of upper airway collapsibility and their mechanical properties, the effects of age and gender on upper airway geometry, and surface properties. The review also discusses how COPD and asthma affect the upper airway and the typical inhalation flow characteristics exhibited by the patients with these diseases.
Collapse
|
3
|
Kurumaddali A, Christopher D, Strickland H, Morgan B, Wiggenhorn C, Stein S, Lyapustina S, Hochhaus G. Evaluation of the Sensitivity and Robustness of Modified Chi-Square Ratio Statistic for Cascade Impactor Equivalence Testing Through Monte Carlo Simulations. AAPS PharmSciTech 2020; 21:147. [PMID: 32435854 DOI: 10.1208/s12249-020-01664-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2020] [Accepted: 03/20/2020] [Indexed: 11/30/2022] Open
Abstract
The objective of this work was to study the performance of the modified chi-square ratio statistic (mCSRS test) proposed for cascade impactor (CI) profile equivalence testing. The test (T) and reference (R) CI profile datasets were generated from different typical CI profile patterns either with or without inter-site correlation (ISC) through Monte Carlo simulations. The mCSRS test pass rate outcome employing previously published critical values was compared with that of critical values derived from different types of datasets. The influence of number of bootstrap iterations (B) on the consistency of the outcome was assessed within the range of 10-10,000 iterations. Power curves were constructed to study the effect of differences in T and R mean stage deposition, T/R variance ratios, differences between T and R profiles in high/low deposition sites, and sample size on the performance of the mCSRS test. The derived critical values exhibited trends based on R product variability: M1 rank-ordered without ISC (at low variability) and the previously published M8 critical values (at high variability) resulted in lowest pass rate outcomes. The precision of the outcome did not increase considerably beyond B = 2000 (default). The probability of showing equivalence between T and R CI profiles increased with (1) a decrease in mean deposition differences, (2) a decrease in T product variability, and (3) an increase in sample size. The mCSRS outcome is less sensitive to low deposition sites that are prone to analytical variability. In conclusion, the mCSRS test is a sensitive and robust method under most conditions.
Collapse
Affiliation(s)
- Abhinav Kurumaddali
- Department of Pharmaceutics, College of Pharmacy, University of Florida, Box 100494, Gainesville, Florida, 32610, USA
| | | | | | - Beth Morgan
- Statistics, AstraZeneca, Durham, North Carolina, USA
| | | | - Stephen Stein
- R&D, 3M Drug Delivery Systems Division, 3M Company, St. Paul, Minnesota, USA
| | - Svetlana Lyapustina
- Pharmaceutical Practice Group, Drinker Biddle and Reath LLP, Washington, District of Columbia, USA
| | - Günther Hochhaus
- Department of Pharmaceutics, College of Pharmacy, University of Florida, Box 100494, Gainesville, Florida, 32610, USA.
| |
Collapse
|
4
|
Kurumaddali A, Christopher D, Sandell D, Strickland H, Morgan B, Bulitta J, Wiggenhorn C, Stein S, Lyapustina S, Hochhaus G. Cascade Impactor Equivalence Testing: Comparison of the Performance of the Modified Chi-Square Ratio Statistic (mCSRS) with the Original CSRS and EMA's Average Bioequivalence Approach. AAPS PharmSciTech 2019; 20:249. [PMID: 31286316 DOI: 10.1208/s12249-019-1443-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2019] [Accepted: 06/03/2019] [Indexed: 11/30/2022] Open
Abstract
The performances of three statistical approaches for assessing in vitro equivalence was evaluated with a set of 55 scenarios of realistic test (T) and reference (R) cascade impactor (CI) profiles (originally employed by the Product Quality Research Institute to evaluate the chi-square ratio statistic: CSRS) by comparing the outcomes against experts' opinion (surrogate for the truth). The three methods were (A) a stepwise aerodynamic particle size distribution (APSD) equivalence test integrating population bioequivalence (PBE) testing of impactor-sized mass (ISM) with the CSRS (PBE-CSRS approach), previously suggested by the USFDA; (B) the combination of PBE testing of single actuation content and ISM with the newly suggested modified CSRS (PBE-mCSRS approach), a method employing reference variance scaling; and (C) EMA's average bioequivalence (ABE approach). Based on Monte-Carlo simulations, both PBE-CSRS and ABE approaches resulted in high misclassification rates, the former with highest false-pass rate and the latter with highest false-fail rate at both ≥ 50% and ≥ 80% classification threshold values (the % of simulations or experts necessary to judge a given scenario as equivalent). Based on DeLong's tests, the PBE-mCSRS approach showed significantly better overall agreement with experts' opinion compared to the other approaches. Comparison of CSRS with mCSRS (both without PBE) suggested that the more discriminatory characteristics of the mCSRS method is based on the integration of variance scaling into the mCSRS method. Contrary to the ABE approach, the application of PBE-mCSRS approach for assessing APSD profiles of three dry powder inhaler (DPI) formulations supported the pharmacokinetic bioequivalence assessment of these formulations.
Collapse
|
5
|
Hoffelder T, Wellek S. Equivalence Testing With Particle Size Distribution Data: Methods and Applications in the Development of Inhalative Drugs. Stat Biopharm Res 2017. [DOI: 10.1080/19466315.2016.1173581] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Affiliation(s)
| | - Stefan Wellek
- Department of Biostatistics, CIMH Mannheim, Mannheim Medical School of the University of Heidelberg, Mannheim, Germany
- Department of Medical Biostatistics, Epidemiology & Informatics, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany
| |
Collapse
|
6
|
Weber B, Lee SL, Delvadia R, Lionberger R, Li BV, Tsong Y, Hochhaus G. Application of the modified chi-square ratio statistic in a stepwise procedure for cascade impactor equivalence testing. AAPS JOURNAL 2014; 17:370-9. [PMID: 25515206 DOI: 10.1208/s12248-014-9698-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2014] [Accepted: 11/03/2014] [Indexed: 11/30/2022]
Abstract
Equivalence testing of aerodynamic particle size distribution (APSD) through multi-stage cascade impactors (CIs) is important for establishing bioequivalence of orally inhaled drug products. Recent work demonstrated that the median of the modified chi-square ratio statistic (MmCSRS) is a promising metric for APSD equivalence testing of test (T) and reference (R) products as it can be applied to a reduced number of CI sites that are more relevant for lung deposition. This metric is also less sensitive to the increased variability often observed for low-deposition sites. A method to establish critical values for the MmCSRS is described here. This method considers the variability of the R product by employing a reference variance scaling approach that allows definition of critical values as a function of the observed variability of the R product. A stepwise CI equivalence test is proposed that integrates the MmCSRS as a method for comparing the relative shapes of CI profiles and incorporates statistical tests for assessing equivalence of single actuation content and impactor sized mass. This stepwise CI equivalence test was applied to 55 published CI profile scenarios, which were classified as equivalent or inequivalent by members of the Product Quality Research Institute working group (PQRI WG). The results of the stepwise CI equivalence test using a 25% difference in MmCSRS as an acceptance criterion provided the best matching with those of the PQRI WG as decisions of both methods agreed in 75% of the 55 CI profile scenarios.
Collapse
Affiliation(s)
- Benjamin Weber
- Department of Pharmaceutics, College of Pharmacy, Center of Pharmacometrics and Systems Pharmacology, University of Florida, Gainesville, FL, USA
| | | | | | | | | | | | | |
Collapse
|
7
|
Sandell D, Mitchell JP. Considerations for Designing In Vitro Bioequivalence (IVBE) Studies for Pressurized Metered Dose Inhalers (pMDIs) with Spacer or Valved Holding Chamber (S/VHC) Add-on Devices. J Aerosol Med Pulm Drug Deliv 2014; 28:156-81. [PMID: 25089555 DOI: 10.1089/jamp.2014.1150] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND The choice of analytical test methods and associated statistical considerations are considered for the laboratory testing of pressurized metered dose inhaler-spacer/valved holding chamber (pMDI-S/VHC) combinations for in vitro bioequivalence (IVBE). METHODS Four scenarios are presented for comparing TEST ("second entry" or "generic") versus REF ("innovator"): (1) innovator and second entry product pMDI alone without any S/VHC (baseline comparison); (2) innovator and second entry pMDI product with the same S/VHC; (3) innovator pMDI product with existing S/VHC and second entry product with a different S/VHC; and (4) introduction of a second, different S/VHC to be used with a given innovator pMDI product. The following aspects should be reviewed in the preparatory stage of designing experiments to establish IVBE: (a) the inclusion of delayed inhalation; (b) the utilization of age-appropriate flow rates; and (c) the use of anatomically appropriate face models for evaluation of devices with a facemask. Statistical considerations that fit in with such experimental methods include: selection of pMDI batches and S/VHC lots; choice of sample size and acceptance criteria; bracketing or worst case approaches; and balanced/paired designs. A stepwise approach for selection of impactor stage groupings is presented, and an approach to determine realistic acceptance criteria based on REF product characteristics is suggested. RESULTS An example of an efficient statistical design of experiment is provided for each scenario, together with alternate approaches for calculation of confidence intervals for the mean TEST/REF relationship. It is important to appreciate that the optimal design depends on balancing numerous considerations and will thus likely differ from case to case; hence, the designs presented here should be seen as illustrations rather than the only option available. More effective approaches may be found that suit a particular case at hand. CONCLUSIONS The information provided will assist in developing correlations in support of IVBE for these add-on devices.
Collapse
Affiliation(s)
| | - Jolyon P Mitchell
- 2Jolyon Mitchell Inhaler Consulting Services Inc., London, ON, Canada
| |
Collapse
|
8
|
Abstract
Interest in bioequivalence (BE) of inhaled drugs derives largely from the desire to offer generic substitutes to successful drug products. The complexity of aerosol dosage forms renders them difficult to mimic and raises questions regarding definitions of similarities and those properties that must be controlled to guarantee both the quality and the efficacy of the product. Despite a high level of enthusiasm to identify and control desirable properties there is no clear guidance, regulatory or scientific, for the variety of aerosol dosage forms, on practical measures of BE from which products can be developed. As more data on the pharmaceutical and clinical relevance of various techniques, as described in this review, become available, it is likely that a path to the demonstration of BE will become evident. In the meantime, debate on this topic will continue.
Collapse
|
9
|
Weber B, Lee SL, Lionberger R, Li BV, Tsong Y, Hochhaus G. A sensitivity analysis of the modified chi-square ratio statistic for equivalence testing of aerodynamic particle size distribution. AAPS JOURNAL 2013; 15:465-76. [PMID: 23344791 DOI: 10.1208/s12248-013-9453-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2012] [Accepted: 01/04/2013] [Indexed: 11/30/2022]
Abstract
Demonstration of equivalence in aerodynamic particle size distribution (APSD) is one key component for establishing bioequivalence of orally inhaled drug products. We previously proposed a modified version of the Chi-square ratio statistic (mCSRS) for APSD equivalence testing and demonstrated that the median of the distribution of the mCSRS (MmCSRS) is a robust metric when test (T) and reference (R) cascade impactor (CI) profiles are identical. Here, we systematically evaluate the behavior of the MmCSRS when T and R CI profiles differ from each other in their mean deposition and variability on a single and multiple sites. All CI profiles were generated by Monte-Carlo simulations based upon modified actual CI data. Twenty thousand sets of 30 T and 30 R CI profiles were simulated for each scenario, and the behavior of the MmCSRS was correlated to metrics that characterize the difference between T and R product in mean deposition and variability. The two key findings were, first, that the MmCSRS is more sensitive to difference between T and R CI profiles on high deposition sites, and second, that a cut-off value for APSD equivalence testing based on the MmCSRS needs to be scaled on the variability of the R product. The former is considered as beneficial for equivalence testing of CI profiles as it decreases the likelihood of failing identical CI profiles by chance, in part, due to increasing analytical variability associated with lower deposition sites. The latter is expected to be important for consistently being able to discriminate equivalent from inequivalent CI profiles.
Collapse
Affiliation(s)
- Benjamin Weber
- Department of Pharmaceutics, College of Pharmacy, Center of Pharmacometrics and Systems Pharmacology, University of Florida, Gainesville, FL, USA
| | | | | | | | | | | |
Collapse
|
10
|
Weber B, Hochhaus G, Adams W, Lionberger R, Li B, Tsong Y, Lee SL. A stability analysis of a modified version of the chi-square ratio statistic: implications for equivalence testing of aerodynamic particle size distribution. AAPS JOURNAL 2012; 15:1-9. [PMID: 23008161 DOI: 10.1208/s12248-012-9410-1] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/25/2012] [Accepted: 09/10/2012] [Indexed: 11/30/2022]
Abstract
Demonstration of equivalence in aerodynamic particle size distribution (APSD; e.g., by comparing cascade impactor (CI) profiles) constitutes one of key in vitro tests for supporting bioequivalence between test (T) and reference (R) orally inhaled drug products (OIDPs). A chi-square ratio statistic (CSRS) was previously proposed for equivalence testing of CI profiles. However, it was reported that the CSRS could not consistently discriminate between equivalent and inequivalent CI profiles. The objective of the overall project was to develop a robust and sensitive methodology for assessing equivalence of APSD profiles of T and R OIDPs. We propose here a modified version of the CSRS (mCSRS) and evaluated systematically its behavior when T and R CI profiles were identical. Different scenarios comprising CI profiles with different number of deposition sites and shapes were generated by Monte-Carlo simulation. For each scenario, the mCSRS was applied to 20,000 independent sets of 30 T and 30 R CI profiles that were identical. Different metrics (including mean and median) of the distribution of 900 mCSRSs (30 T × 30 R) were then evaluated for their suitability as a test statistic (i.e., independent of the number of sites and shape of the CI profile) for APSD equivalence testing. The median of the distribution of 900 mCSRSs (MmCSRS) was one regardless of the number of sites and shape of the CI profile. Hence, the MmCSRS is a robust metric for CI profile equivalence testing when T and R CI profiles are identical and potentially useful for APSD equivalence testing.
Collapse
Affiliation(s)
- Benjamin Weber
- Department of Pharmaceutics, College of Pharmacy, Center of Pharmacometrics and Systems Pharmacology, University of Florida, Gainesville, FL, USA
| | | | | | | | | | | | | |
Collapse
|
11
|
Mitchell J, Dolovich MB. Clinically Relevant Test Methods to EstablishIn VitroEquivalence for Spacers and Valved Holding Chambers Used with Pressurized Metered Dose Inhalers (pMDIs). J Aerosol Med Pulm Drug Deliv 2012; 25:217-42. [DOI: 10.1089/jamp.2011.0933] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Affiliation(s)
| | - Myrna B. Dolovich
- Faculty of Health Sciences, McMaster University, Hamilton, ON, Canada
| |
Collapse
|
12
|
Alexander BD, Winkler TP, Shi S, Dodds Ashley ES, Hickey AJ. In vitro characterization of nebulizer delivery of liposomal amphotericin B aerosols. Pharm Dev Technol 2011; 16:577-82. [PMID: 21699390 DOI: 10.3109/10837450.2011.591803] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Pharmaceutical aerosols have the potential to prevent pulmonary infectious diseases. Liposomal amphotericin B (LAMB, Ambisome, Astellas Pharma US, Deerfield, IL, USA) is approved as an intravenous infusion for empiric treatment of presumed fungal infections in neutropenic, febrile patients, as well as patients infected with Aspergillus, Cryptococcus, and other fungal pathogens. In this study, four different nebulizers were tested for their ability to deliver LAMB in aerodynamic droplet-size ranges relevant to lung deposition by an inertial sampling technique Mass median aerodynamic diameter (MMAD) and fine particle fraction percent <3.3 μm (FPF(3.3)) and <5.8 μm (FPF(5.8)) were determined by cascade impaction during a 2 min sampling period for each of three trials of all nebulizers. The MMADs for all nebulizers ranged from 1.72 ± 0.11 μm to 2.89 ± 0.12 μm; FPF(3.3) and FPF(5.8) were approximately 80% and 90%, respectively. Although all nebulizers appear acceptable for delivery of LAMB, the Pari LC Star and the Aeroeclipse II were considered the best in terms of delivery of aerosol efficiently and the proportion suitable for lung deposition. Additional research on pulmonary delivery and clinical tolerability is warranted.
Collapse
Affiliation(s)
- Barbara D Alexander
- Division of Infectious Diseases, Department of Medicine, Duke University, Durham, NC 27710, USA.
| | | | | | | | | |
Collapse
|
13
|
Adams WP, Ahrens RC, Chen ML, Christopher D, Chowdhury BA, Conner DP, Dalby R, Fitzgerald K, Hendeles L, Hickey AJ, Hochhaus G, Laube BL, Lucas P, Lee SL, Lyapustina S, Li B, O'Connor D, Parikh N, Parkins DA, Peri P, Pitcairn GR, Riebe M, Roy P, Shah T, Singh GJP, Sharp SS, Suman JD, Weda M, Woodcock J, Yu L. Demonstrating Bioequivalence of Locally Acting Orally Inhaled Drug Products (OIPs): Workshop Summary Report. J Aerosol Med Pulm Drug Deliv 2010; 23:1-29. [DOI: 10.1089/jamp.2009.0803] [Citation(s) in RCA: 79] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Affiliation(s)
- Wallace P. Adams
- Food and Drug Administration, Center for Drug Evaluation and Research, Office of Pharmaceutical Science, Office of Generic Drugs, Rockville, Maryland
| | - Richard C. Ahrens
- University of Iowa Hospitals and Clinics, Department of Pediatrics, Iowa City, Iowa
| | - Mei-Ling Chen
- Food and Drug Administration, Center for Drug Evaluation and Research, Silver Spring, Maryland
| | | | - Badrul A. Chowdhury
- Food and Drug Administration, Center for Drug Evaluation and Research, Silver Spring, Maryland
| | - Dale P. Conner
- Food and Drug Administration, Center for Drug Evaluation and Research, Office of Pharmaceutical Science, Office of Generic Drugs, Rockville, Maryland
| | | | | | | | | | - Günther Hochhaus
- Department of Pharmaceutics, College of Pharmacy, University of Florida, Gainesville, Florida
| | - Beth L. Laube
- Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Paul Lucas
- Pfizer Global Research and Development, Sandwich, Kent, CT13 9NJ, United Kingdom
| | - Sau L. Lee
- Food and Drug Administration, Center for Drug Evaluation and Research, Office of Pharmaceutical Science, Office of Generic Drugs, Rockville, Maryland
| | | | - Bing Li
- Food and Drug Administration, Center for Drug Evaluation and Research, Office of Pharmaceutical Science, Office of Generic Drugs, Rockville, Maryland
| | - Dennis O'Connor
- Boehringer Ingelheim Pharmaceuticals, Inc., Ridgefield, Connecticut
| | | | | | - Prasad Peri
- Food and Drug Administration, Center for Drug Evaluation and Research, Silver Spring, Maryland
| | - Gary R. Pitcairn
- Pfizer Limited, Ramsgate Road, Sandwich, Kent, CT13 9NJ, United Kingdom
| | | | - Partha Roy
- Food and Drug Administration, Center for Drug Evaluation and Research, Silver Spring, Maryland
| | | | | | - Sandra Suarez Sharp
- Food and Drug Administration, Center for Drug Evaluation and Research, Silver Spring, Maryland
| | | | - Marjolein Weda
- National Institute for Public Health and the Environment (RIVM) Centre for Quality of Chemical-Pharmaceutical Products, Bilthoven, The Netherlands
| | - Janet Woodcock
- Food and Drug Administration, Center for Drug Evaluation and Research, Silver Spring, Maryland
| | - Lawrence Yu
- Food and Drug Administration, Center for Drug Evaluation and Research, Office of Pharmaceutical Science, Office of Generic Drugs, Rockville, Maryland
| |
Collapse
|
14
|
Shi S, Hickey AJ. Multivariate data analysis as a semi-quantitative tool for interpretive evaluation of comparability or equivalence of aerodynamic particle size distribution profiles. AAPS PharmSciTech 2009; 10:1113-20. [PMID: 19763839 DOI: 10.1208/s12249-009-9303-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2009] [Accepted: 08/20/2009] [Indexed: 12/25/2022] Open
Abstract
The purpose of this article is to investigate the performance of multivariate data analysis, especially orthogonal partial least square (OPLS) analysis, as a semi-quantitative tool to evaluate the comparability or equivalence of aerodynamic particle size distribution (APSD) profiles of orally inhaled and nasal drug products (OINDP). Monte Carlo simulation was employed to reconstitute APSD profiles based on 55 realistic scenarios proposed by the Product Quality Research Institute (PQRI) working group. OPLS analyses with different data pretreatment methods were performed on each of the reconstituted profiles. Compared to unit-variance scaling, equivalence determined based on OPLS analysis with Pareto scaling was shown to be more consistent with the working group assessment. Chi-square statistics was employed to compare the performance of OPLS analysis (Pareto scaling) with that of the combination test (i.e., chi-square ratio statistics and population bioequivalence test for impactor-sized mass) in terms of achieving greater consistency with the working group evaluation. A p value of 0.036 suggested that OPLS analysis with Pareto scaling may be more predictive than the combination test with respect to consistency. Furthermore, OPLS analysis may also be employed to analyze part of the APSD profiles that contribute to the calculation of the mass median aerodynamic diameter. Our results show that OPLS analysis performed on partial deposition sites do not interfere with the performance on all deposition sites.
Collapse
|
15
|
|
16
|
Mitchell JP, Nagel MW, Avvakoumova V, MacKay H, Ali R. The abbreviated impactor measurement (AIM) concept: part 1--Influence of particle bounce and re-entrainment-evaluation with a "dry" pressurized metered dose inhaler (pMDI)-based formulation. AAPS PharmSciTech 2009; 10:243-51. [PMID: 19280348 DOI: 10.1208/s12249-009-9202-9] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2008] [Accepted: 02/11/2009] [Indexed: 11/30/2022] Open
Abstract
The abbreviated impactor measurement concept is a potential improvement to the labor-intensive full-resolution cascade impactor methodology for inhaler aerosol aerodynamic particle size distribution (APSD) measurement by virtue of being simpler and therefore quicker to execute. At the same time, improved measurement precision should be possible by eliminating stages upon which little or no drug mass is collected. Although several designs of abbreviated impactor systems have been developed in recent years, experimental work is lacking to validate the technique with aerosols produced by currently available inhalers. In part 1 of this two-part article that focuses on aerosols produced by pressurized metered dose inhalers (pMDIs), the evaluation of two abbreviated impactor systems (Copley fast screening Andersen impactor and Trudell fast screening Andersen impactor), based on the full-resolution eight-stage Andersen nonviable cascade impactor (ACI) operating principle, is reported with a formulation producing dry particles. The purpose was to investigate the potential for non-ideal collection behavior associated with particle bounce in relation to internal losses to surfaces from which particles containing active pharmaceutical ingredient are not normally recovered. Both abbreviated impactors were found to be substantially equivalent to the full-resolution ACI in terms of extra-fine and fine particle and coarse mass fractions used as metrics to characterize the APSD of these pMDI-produced aerosols when sampled at 28.3 L/min, provided that precautions are taken to coat collection plates to minimize bounce and entrainment.
Collapse
|
17
|
Kamiya A, Sakagami M, Byron PR. Cascade Impactor Practice for a High Dose Dry Powder Inhaler at 90 L/min: NGI Versus Modified 6-Stage and 8-Stage ACI. J Pharm Sci 2009; 98:1028-39. [DOI: 10.1002/jps.21501] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
18
|
Shi S, Dodds Ashley ES, Alexander BD, Hickey AJ. Initial characterization of micafungin pulmonary delivery via two different nebulizers and multivariate data analysis of aerosol mass distribution profiles. AAPS PharmSciTech 2009; 10:129-37. [PMID: 19189220 DOI: 10.1208/s12249-009-9185-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2008] [Accepted: 12/31/2008] [Indexed: 12/25/2022] Open
Abstract
Pharmaceutical aerosols have been targeted to the lungs for the treatment of asthma and pulmonary infectious diseases successfully. Micafungin (Astellas Pharma US, Deerfield, IL, USA) has been shown to be an effective antifungal agent when administrated intravenously. Pulmonary delivery of micafungin has not previously been reported. In the present pilot study, we characterize the performance of two nebulizers and their potential for delivering micafungin to the lungs as well as the use of multivariate data analysis for mass distribution profile comparison. The concentration of micafungin sodium increased by 21% when delivered by the Acorn II nebulizer and by 20% when delivered by the LC Plus nebulizer, respectively, from the first to the second sampling period. The Acorn II nebulizer delivered a fine particle fraction FPF(5.8) (%<5.8 microm) of 92.5 +/- 0.8 and FPF(3.3) (%<3.3 microm) of 82.3 +/- 2.1 during the first sampling period. For the LC Plus nebulizer, FPF(5.8) was 92.3 +/- 0.1 and FPF(3.3) was 67.0 +/- 0.7 during the first sampling period. The mass median aerodynamic diameter (MMAD) increased from 1.67 +/- 0.05 to 1.77 +/- 0.04 mum (Acorn II nebulizer) and from 2.09 +/- 0.01 to 2.20 +/- 0.01 microm (Pari LC Plus nebulizer) from the first to the second sampling periods. These changes in MMAD were statistically significant by paired t test. Multivariate data analysis showed that this could be explained systematically by greater drug deposition on stages with larger cutoff sizes and reduced drug deposition on stages with smaller cutoff sizes rather than multimodal deposition or other anomalies in size distribution.
Collapse
|
19
|
Mitchell J, Newman S, Chan HK. In vitro and in vivo aspects of cascade impactor tests and inhaler performance: a review. AAPS PharmSciTech 2007; 8:E110. [PMID: 18181531 DOI: 10.1208/pt0804110] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
The purpose of this review is to discuss the roles of cascade impactor (CI) data in inhaler assessment and to examine the relationship between aerodynamic particle size distribution (APSD) and the clinical response to inhaled drugs. A systematic literature search of studies linking APSD to clinical response was undertaken. Two distinct roles for CI-generated data were identified: (1) the control of inhaler/drug product quality; and (2) the provision of data that may be predictive of particle deposition in the respiratory tract. Method robustness is required for the former application, combined with simplicity in operation, resulting in rudimentary attempts to mimic the anatomy of the respiratory tract. The latter necessitates making the apparatus and its operation more closely resemble patient use of the inhaler. A CI cannot perfectly simulate the respiratory tract, since it operates at constant flow rate, while the respiratory cycle has a varying flow-time profile. On the basis of a review of studies linking APSD to clinical response of inhaled drugs, it is concluded that attempts to use CI-generated data from quality control testing to compare products for bioequivalence are likely to have only limited success, as links between laboratory-measured APSD, particle deposition in the respiratory tract, and clinical response are not straightforward.
Collapse
|
20
|
Christopher D, Adams W, Amann A, Bertha C, Byron PR, Doub W, Dunbar C, Hauck W, Lyapustina S, Mitchell J, Morgan B, Nichols S, Pan Z, Pal Singh GJ, Tougas T, Tsong Y, Wolff R, Wyka B. Product Quality Research Institute evaluation of cascade impactor profiles of pharmaceutical aerosols. Part 3. Final report on a statistical procedure for determining equivalence. AAPS PharmSciTech 2007; 8:E90. [PMID: 18181550 DOI: 10.1208/pt0804090] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
The purpose of this article is to report final results of the evaluation of a chi-square ratio test proposed by the US Food and Drug Administration (FDA) for demonstrating equivalence of aerodynamic particle size distribution (APSD) profiles of nasal and orally inhaled drug products. A working group of the Product Quality Research Institute previously published results demonstrating some limitations of the proposed test. In an effort to overcome the test's limited discrimination, the group proposed a supplemental test, a population bioequivalence (PBE) test for impactor-sized mass (ISM). In this final report the group compares the chi-square ratio test to the ISM-PBE test and to the combination of both tests. The basis for comparison is a set of 55 realistic scenarios of cascade impactor data, which were evaluated for equivalence by the statistical tests and independently by the group members. In many instances, the combined application of these 2 tests appeared to increase the discriminating ability of the statistical procedure compared with the chi-square ratio test alone. In certain situations the chi-square ratio test alone was sufficient to determine equivalence of APSD profiles, while in other situations neither of the tests alone nor their combination was adequate. This report describes all of these scenarios and results. In the end, the group did not recommend a statistical test for APSD profile equivalence. The group did not investigate other in vitro tests, in vivo issues, or other statistical tests for APSD profile comparisons. The studied tests are not intended for routine quality control of APSD.
Collapse
|