• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4625220)   Today's Articles (1177)   Subscriber (49508)
For: Hansen R, Koster A, Kukucka M, Mertzlufft F, Kuppe H. A Quick Anti-Xa-Activity-Based Whole Blood Coagulation Assay for Monitoring Unfractionated Heparin During Cardiopulmonary Bypass: A Pilot Investigation. Anesth Analg 2000. [DOI: 10.1213/00000539-200009000-00006] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Number Cited by Other Article(s)
1
Preparation and anticoagulant properties of heparin-like electrospun membranes from carboxymethyl chitosan and bacterial cellulose sulfate. Int J Biol Macromol 2018;120:1396-1405. [DOI: 10.1016/j.ijbiomac.2018.09.133] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Revised: 08/27/2018] [Accepted: 09/22/2018] [Indexed: 12/15/2022]
2
The Society of Thoracic Surgeons, The Society of Cardiovascular Anesthesiologists, and The American Society of ExtraCorporeal Technology: Clinical Practice Guidelines ∗ —Anticoagulation During Cardiopulmonary Bypass. Ann Thorac Surg 2018;105:650-662. [DOI: 10.1016/j.athoracsur.2017.09.061] [Citation(s) in RCA: 55] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2017] [Accepted: 09/09/2017] [Indexed: 01/01/2023]
3
Shore-Lesserson L, Baker RA, Ferraris VA, Greilich PE, Fitzgerald D, Roman P, Hammon JW. The Society of Thoracic Surgeons, The Society of Cardiovascular Anesthesiologists, and The American Society of ExtraCorporeal Technology. Anesth Analg 2018;126:413-424. [DOI: 10.1213/ane.0000000000002613] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
4
Oliver WC. Overview of Heparin and Protamine Management and Dosing Regimens in Pediatric Cardiac Surgical Patients. Semin Cardiothorac Vasc Anesth 2016. [DOI: 10.1177/108925320300700404] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
5
Measurement of Non-Vitamin K Antagonist Oral Anticoagulants in Patient Plasma Using Heptest-STAT Coagulation Method. Ther Drug Monit 2016;37:375-80. [PMID: 25525760 DOI: 10.1097/ftd.0000000000000157] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
6
Yan-mei W, Jian-bing S, Tong B, Jun-ge Z, Yu-ping D. A WATER-SOLUBLE DUAL-CHANNEL FLUORESCENCE-ENHANCED BIOSENSOR FOR HEPARIN BASED ON A CATIONIC CONJUGATED POLYELECTROLYTE CONTAINING TETRAPHENYLETHENE AND 2,1,3-BENZOTHIADIAZOLE. ACTA POLYM SIN 2013. [DOI: 10.3724/sp.j.1105.2012.12108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
7
Koster A, Despotis G, Gruendel M, Fischer T, Praus M, Kuppe H, Levy JH. The plasma supplemented modified activated clotting time for monitoring of heparinization during cardiopulmonary bypass: a pilot investigation. Anesth Analg 2002;95:26-30, table of contents. [PMID: 12088937 DOI: 10.1097/00000539-200207000-00004] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
8
Henry TD, Satran D, Knox LL, Iacarella CL, Laxson DD, Antman EM. Are activated clotting times helpful in the management of anticoagulation with subcutaneous low-molecular-weight heparin? Am Heart J 2001;142:590-3. [PMID: 11579347 DOI: 10.1067/mhj.2001.117317] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA