• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4635029)   Today's Articles (1714)   Subscriber (50028)
For: Lefoll-Masson C, Fermanian C, Aimé I, Verroust N, Taylor G, Laloë PA, Liu N, Aegerter P, Fischler M. The Comparability of Bispectral Index and State Entropy Index During Maintenance of Sufentanil-Sevoflurane-Nitrous Oxide Anesthesia. Anesth Analg 2007;105:1319-25, table of contents. [DOI: 10.1213/01.ane.0000287247.30810.aa] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Number Cited by Other Article(s)
1
Yoo JH, Ok SY, Kim SH, Chung JW, Park SY, Kim MG, Cho HB, Song SH, Choi SJ, Oh HC. Comparison of bispectral index and phase lag entropy during general anesthesia: Sevoflurane or propofol anesthesia. Medicine (Baltimore) 2022;101:e31191. [PMID: 36343067 PMCID: PMC9646625 DOI: 10.1097/md.0000000000031191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]  Open
2
Liang T, Wu F, Wang B, Mu F. PRISMA: accuracy of response entropy and bispectral index to predict the transition of consciousness during sevoflurane anesthesia: A systematic review and meta-analysis. Medicine (Baltimore) 2021;100:e25718. [PMID: 33907161 PMCID: PMC8084050 DOI: 10.1097/md.0000000000025718] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2020] [Revised: 03/15/2021] [Accepted: 04/12/2021] [Indexed: 11/27/2022]  Open
3
Chen W, Feng Y, Chen X, Jiang F, Miao J, Chen S, Chen H. Effect of Laryngeal Mask Airway Insertion on Parameters Derived From Catacrotic Phase of Photoplethysmography Under Different Concentrations of Remifentanil. IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE 2020;8:2700609. [PMID: 33178499 PMCID: PMC7647452 DOI: 10.1109/jtehm.2020.3017368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/12/2020] [Revised: 05/25/2020] [Accepted: 07/29/2020] [Indexed: 11/07/2022]
4
Navarrete-Calvo R, Morgaz J, Gómez-Villamandos RJ, Quirós-Carmona S, Domínguez JM, Ruiz-López P, Granados MM. Comparison of bispectral index and spectral entropy during isoflurane and medetomidine general anaesthesia in horses. Equine Vet J 2020;52:678-684. [PMID: 31961457 DOI: 10.1111/evj.13234] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Revised: 12/20/2019] [Accepted: 01/12/2020] [Indexed: 11/28/2022]
5
Burk KM, Sakata DJ, Kuck K, Orr JA. Comparing Nasal End-Tidal Carbon Dioxide Measurement Variation and Agreement While Delivering Pulsed and Continuous Flow Oxygen in Volunteers and Patients. Anesth Analg 2019;130:715-724. [PMID: 30633057 DOI: 10.1213/ane.0000000000004004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
6
Messina AG, Wang M, Ward MJ, Wilker CC, Smith BB, Vezina DP, Pace NL. Anaesthetic interventions for prevention of awareness during surgery. Cochrane Database Syst Rev 2016;10:CD007272. [PMID: 27755648 PMCID: PMC6461159 DOI: 10.1002/14651858.cd007272.pub2] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
7
Differences between state entropy and bispectral index during analysis of identical electroencephalogram signals: a comparison with two randomised anaesthetic techniques. Eur J Anaesthesiol 2016;32:354-65. [PMID: 25564779 DOI: 10.1097/eja.0000000000000189] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
8
Short TG, Leslie K, Chan MTV, Campbell D, Frampton C, Myles P. Rationale and Design of the Balanced Anesthesia Study: A Prospective Randomized Clinical Trial of Two Levels of Anesthetic Depth on Patient Outcome After Major Surgery. Anesth Analg 2015;121:357-65. [PMID: 25993386 DOI: 10.1213/ane.0000000000000797] [Citation(s) in RCA: 62] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
9
Aho A, Kamata K, Jäntti V, Kulkas A, Hagihira S, Huhtala H, Yli-Hankala A. Comparison of Bispectral Index and Entropy values with electroencephalogram during surgical anaesthesia with sevoflurane †. Br J Anaesth 2015;115:258-66. [DOI: 10.1093/bja/aev206] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/08/2015] [Indexed: 11/13/2022]  Open
10
Sharma A, Singh PM, Trikha A, Rewari V. Entropy correlates with Richmond Agitation Sedation Scale in mechanically ventilated critically ill patients. J Clin Monit Comput 2014;28:193-201. [PMID: 24122077 DOI: 10.1007/s10877-013-9517-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2012] [Accepted: 10/04/2013] [Indexed: 11/26/2022]
11
Aimé I, Gayat E, Fermanian C, Cook F, Peuch C, Laloë P, Mantz J, Fischler M. Effect of age on the comparability of bispectral and state entropy indices during the maintenance of propofol–sufentanil anaesthesia. Br J Anaesth 2012;108:638-43. [DOI: 10.1093/bja/aer457] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]  Open
12
Comparison of spectral entropy and BIS VISTA™ monitor during general anesthesia for cardiac surgery. J Clin Monit Comput 2011;25:95-103. [PMID: 21512777 DOI: 10.1007/s10877-011-9280-6] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2011] [Accepted: 04/08/2011] [Indexed: 10/18/2022]
13
Does Nitrous Oxide Affect Bispectral Index and State Entropy When Added to a Propofol Versus Sevoflurane Anesthetic? J Neurosurg Anesthesiol 2010;22:309-15. [DOI: 10.1097/ana.0b013e3181e4b7c8] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
14
Mostafa Ka N, Omar S, Radwan K, Youssef A. Bispectral Index Monitoring Tailors Clinical Anesthetic Delivery and Reduces Anesthetic Drug Consumption. JOURNAL OF MEDICAL SCIENCES 2008. [DOI: 10.3923/jms.2009.10.16] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]  Open
15
Huang HH, Lee YH, Chan HL, Wang YP, Huang CH, Fan SZ. Using a short-term parameter of heart rate variability to distinguish awake from isoflurane anesthetic states. Med Biol Eng Comput 2008;46:977-84. [PMID: 18414913 DOI: 10.1007/s11517-008-0342-y] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2007] [Accepted: 03/24/2008] [Indexed: 11/30/2022]
PrevPage 1 of 1 1Next