1
|
Baysan M, Broere M, Wille ME, Bergsma JE, Mik EG, Juffermans NP, Tsonaka R, van der Bom JG, Arbous SM. Description of mitochondrial oxygen tension and its variability in healthy volunteers. PLoS One 2024; 19:e0300602. [PMID: 38829894 PMCID: PMC11146699 DOI: 10.1371/journal.pone.0300602] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Accepted: 02/27/2024] [Indexed: 06/05/2024] Open
Abstract
OBJECTIVES Describing mitochondrial oxygenation (mitoPO2) and its within- and between-subject variability over time after 5-aminolevulinic acid (ALA) plaster application in healthy volunteers. DESIGN Prospective cohort study. SETTING Measurements were performed in Leiden University Medical Center, the Netherlands. PARTICIPANTS Healthy volunteers enrolled from July to September 2020. INTERVENTIONS Two ALA plasters were placed parasternal left and right, with a 3-hour time interval, to examine the influence of the calendar time on the value of mitoPO2. We measured mitoPO2 at 4, 5, 7, 10, 28, and 31 hours after ALA plaster 1 application, and at 4, 5, 7, 25, and 28 hours after ALA plaster 2 application. PRIMARY AND SECONDARY OUTCOME MEASURES At each time point, five mitoPO2 measurements were performed. Within-subject variability was defined as the standard deviation (SD) of the mean of five measurements per timepoint of a study participant. The between-subject variability was the SD of the mean mitoPO2 value of the study population per timepoint. RESULTS In 16 completed inclusions, median mitoPO2 values and within-subject variability were relatively similar over time at all time points for both plasters. An increase in overall between-subject variability was seen after 25 hours ALA plaster time (19.6 mm Hg vs 23.9 mm Hg after respectively 10 and 25 hours ALA plaster time). CONCLUSIONS The mitoPO2 values and within-subject variability remained relatively stable over time in healthy volunteers. An increase in between-subject variability was seen after 25 hours ALA plaster time warranting replacement of the ALA plaster one day after its application. TRIAL REGISTRATION ClinicalTrials.gov with trial number NCT04626661.
Collapse
Affiliation(s)
- Meryem Baysan
- Department of Intensive Care Medicine, Leiden University Medical Center, Leiden, the Netherlands
- Department of Clinical Epidemiology, Leiden University Medical Center, Leiden, the Netherlands
- Jon J van Rood Center for Clinical Transfusion Research, Sanquin/Leiden University Medical Center, Leiden, the Netherlands
| | - Mark Broere
- Department of Intensive Care Medicine, Leiden University Medical Center, Leiden, the Netherlands
- Department of Clinical Epidemiology, Leiden University Medical Center, Leiden, the Netherlands
- Jon J van Rood Center for Clinical Transfusion Research, Sanquin/Leiden University Medical Center, Leiden, the Netherlands
| | - Maarten E. Wille
- Department of Intensive Care Medicine, Leiden University Medical Center, Leiden, the Netherlands
| | - Jule E. Bergsma
- Department of Intensive Care Medicine, Leiden University Medical Center, Leiden, the Netherlands
| | - Egbert G. Mik
- Department of Anesthesiology, Laboratory of Experimental Anesthesiology, Erasmus MC- University Medical Center Rotterdam, Rotterdam, the Netherlands
| | - Nicole P. Juffermans
- Department of Intensive Care Medicine, OLVG Hospital, Amsterdam, the Netherlands
- Department of Laboratory of Translation Intensive Care, Erasmus MC- University Medical Center Rotterdam, Rotterdam, the Netherlands
| | - Roula Tsonaka
- Department of Biomedical Data Sciences, Leiden University Medical Center, Leiden, the Netherlands
| | - Johanna G. van der Bom
- Department of Clinical Epidemiology, Leiden University Medical Center, Leiden, the Netherlands
- Jon J van Rood Center for Clinical Transfusion Research, Sanquin/Leiden University Medical Center, Leiden, the Netherlands
| | - Sesmu M. Arbous
- Department of Intensive Care Medicine, Leiden University Medical Center, Leiden, the Netherlands
- Department of Clinical Epidemiology, Leiden University Medical Center, Leiden, the Netherlands
| |
Collapse
|
2
|
Kandil S, Sedra A. Hemodynamic monitoring in liver transplantation 'the hemodynamic system'. Curr Opin Organ Transplant 2024; 29:72-81. [PMID: 38032246 DOI: 10.1097/mot.0000000000001125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2023]
Abstract
PURPOSE OF REVIEW The purpose of this article is to provide a comprehensive review of hemodynamic monitoring in liver transplantation. RECENT FINDINGS Radial arterial blood pressure monitoring underestimates the aortic root arterial blood pressure and causes excessive vasopressor and worse outcomes. Brachial and femoral artery monitoring is well tolerated and should be considered in critically ill patients expected to be on high dose pressors. The pulmonary artery catheter is the gold standard of hemodynamic monitoring and is still widely used in liver transplantation; however, it is a highly invasive monitor with potential for serious complications and most of its data can be obtained by other less invasive monitors. Rescue transesophageal echocardiography relies on few simple views and should be available as a standby to manage sudden hemodynamic instability. Risk of esophageal bleeding from transesophageal echocardiography in liver transplantation is the same as in other patient populations. The arterial pulse waveform analysis based cardiac output devices are minimally invasive and have the advantage of real-time beat to beat monitoring of cardiac output. No hemodynamic monitor can improve clinical outcomes unless integrated into a goal-directed hemodynamic therapy. The hemodynamic monitoring technique should be tailored to the patient's medical status, surgical technique, and the anesthesiologist's level of expertise. SUMMARY The current article provides a review of the current hemodynamic monitoring systems and their integration in goal-directed hemodynamic therapy.
Collapse
Affiliation(s)
- Sherif Kandil
- Department of Anesthesiology, Keck Medical School of USC, Los Angeles, California, USA
| | | |
Collapse
|
3
|
Goodwin AJ, Eytan D, Dixon W, Goodfellow SD, Doherty Z, Greer RW, McEwan A, Tracy M, Laussen PC, Assadi A, Mazwi M. Timing errors and temporal uncertainty in clinical databases-A narrative review. Front Digit Health 2022; 4:932599. [PMID: 36060541 PMCID: PMC9433547 DOI: 10.3389/fdgth.2022.932599] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Accepted: 07/11/2022] [Indexed: 11/28/2022] Open
Abstract
A firm concept of time is essential for establishing causality in a clinical setting. Review of critical incidents and generation of study hypotheses require a robust understanding of the sequence of events but conducting such work can be problematic when timestamps are recorded by independent and unsynchronized clocks. Most clinical models implicitly assume that timestamps have been measured accurately and precisely, but this custom will need to be re-evaluated if our algorithms and models are to make meaningful use of higher frequency physiological data sources. In this narrative review we explore factors that can result in timestamps being erroneously recorded in a clinical setting, with particular focus on systems that may be present in a critical care unit. We discuss how clocks, medical devices, data storage systems, algorithmic effects, human factors, and other external systems may affect the accuracy and precision of recorded timestamps. The concept of temporal uncertainty is introduced, and a holistic approach to timing accuracy, precision, and uncertainty is proposed. This quantitative approach to modeling temporal uncertainty provides a basis to achieve enhanced model generalizability and improved analytical outcomes.
Collapse
Affiliation(s)
- Andrew J. Goodwin
- Department of Critical Care Medicine, The Hospital for Sick Children, Toronto, ON, Canada
- School of Biomedical Engineering, University of Sydney, Sydney, NSW, Australia
| | - Danny Eytan
- Department of Critical Care Medicine, The Hospital for Sick Children, Toronto, ON, Canada
- Department of Medicine, Technion - Israel Institute of Technology, Haifa, Israel
| | - William Dixon
- Department of Critical Care Medicine, The Hospital for Sick Children, Toronto, ON, Canada
| | - Sebastian D. Goodfellow
- Department of Critical Care Medicine, The Hospital for Sick Children, Toronto, ON, Canada
- Department of Civil and Mineral Engineering, University of Toronto, Toronto, ON, Canada
| | - Zakary Doherty
- Research Fellow, School of Rural Health, Monash University, Melbourne, VIC, Australia
| | - Robert W. Greer
- Department of Critical Care Medicine, The Hospital for Sick Children, Toronto, ON, Canada
| | - Alistair McEwan
- School of Biomedical Engineering, University of Sydney, Sydney, NSW, Australia
| | - Mark Tracy
- Neonatal Intensive Care Unit, Westmead Hospital, Sydney, NSW, Australia
- Department of Paediatrics and Child Health, The University of Sydney, Sydney, NSW, Australia
| | - Peter C. Laussen
- Department of Anesthesia, Boston Children's Hospital, Boston, MA, United States
| | - Azadeh Assadi
- Department of Critical Care Medicine, The Hospital for Sick Children, Toronto, ON, Canada
- Department of Engineering and Applied Sciences, Institute of Biomedical Engineering, University of Toronto, Toronto, ON, Canada
| | - Mjaye Mazwi
- Department of Critical Care Medicine, The Hospital for Sick Children, Toronto, ON, Canada
- Department of Paediatrics, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
4
|
Feldman JM, Kuck K, Hemmerling T. Black Box, Gray Box, Clear Box? How Well Must We Understand Monitoring Devices? Anesth Analg 2021; 132:1777-1780. [PMID: 33780392 DOI: 10.1213/ane.0000000000005500] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- Jeffrey M Feldman
- From the Department of Anesthesiology and Critical Care Medicine, Children's Hospital of Philadelphia, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Kai Kuck
- Department of Anesthesiology, University of Utah, Salt Lake City, Utah
| | - Thomas Hemmerling
- Department of Anesthesia, McGill University, Montreal, Quebec, Canada
| |
Collapse
|
5
|
Milam AJ, Ghoddoussi F, Lucaj J, Narreddy S, Kumar N, Reddy V, Hakim J, Krishnan SH. Comparing the Mutual Interchangeability of ECOM, FloTrac/Vigileo, 3D-TEE, and ITD-PAC Cardiac Output Measuring Systems in Coronary Artery Bypass Grafting. J Cardiothorac Vasc Anesth 2020; 35:514-529. [PMID: 32622708 DOI: 10.1053/j.jvca.2020.03.048] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/15/2020] [Revised: 03/18/2020] [Accepted: 03/24/2020] [Indexed: 01/19/2023]
Abstract
OBJECTIVE The aim of this study was to compare the mutual interchangeability of 4 cardiac output measuring devices by comparing their accuracy, precision, and trending ability. DESIGN A single-center prospective observational study. DESIGN Nonuniversity teaching hospital, single center. PARTICIPANTS Forty-four consecutive patients scheduled for elective, nonemergent coronary artery bypass grafting (CABG). INTERVENTIONS The cardiac output was measured for each participant using 4 methods: intermittent thermodilution via pulmonary artery catheter (ITD-PAC), Endotracheal Cardiac Output Monitor (ECOM), FloTrac/Vigileo System (FLOTRAC), and 3-dimensional transesophageal echocardiography (3D-TEE). MEASUREMENTS AND MAIN RESULTS Measurements were performed simultaneously at 5 time points: presternotomy, poststernotomy, before cardiopulmonary bypass, after cardiopulmonary bypass, and after sternal closure. A series of statistical and comparison analyses including ANOVA, Pearson correlation, Bland-Altman plots, quadrant plots, and polar plots were performed, and inherent precision for each method and percent errors for mutual interchangeability were calculated. For the 6 two-by-two comparisons of the methods, the Pearson correlation coefficients (r), the percentage errors (% error), and concordance ratios (CR) were as follows: ECOM_versus_ITD-PAC (r = 0.611, % error = 53%, CR = 75%); FLOTRAC_versus_ITD-PAC (r = 0.676, % error = 49%, CR = 77%); 3D-TEE versus ITD-PAC (r = 0.538, % error = 64%, CR = 67%); FLOTRAC_versus_ECOM (r = 0.627, % error = 51%, CR = 75%); 3D-TEE_versus ECOM (r = 0.423, % error = 70%, CR = 60%), and 3D-TEE_versus_FLOTRAC (r = 0.602, % error = 59%, CR = 61%). CONCLUSIONS Based on the recommended statistical measures of interchangeability, ECOM, FLOTRAC, and 3D-TEE are not interchangeable with each other or to the reference standard invasive ITD-PAC method in patients undergoing nonemergent cardiac bypass surgery. Despite the negative result in this study and the majority of previous studies, these less-invasive methods of CO have continued to be used in the hemodynamic management of patients. Each device has its own distinct technical features and inherent limitations; it is clear that no single device can be used universally for all patients. Therefore, different methods or devices should be chosen based on individual patient conditions, including the degree of invasiveness, measurement performance, and the ability to provide real-time, continuous CO readings.
Collapse
Affiliation(s)
- Adam J Milam
- Department of Anesthesiology, Cedars-Sinai Medical Center, Los Angeles, CA
| | - Farhad Ghoddoussi
- Department of Anesthesiology, Wayne State University School of Medicine, Detroit, MI
| | - Jon Lucaj
- Department of Anesthesiology, Wayne State University School of Medicine, Detroit, MI; Department of Anesthesiology, St. Joseph Mercy Oakland Hospital, Pontiac, MI
| | - Spurthy Narreddy
- Department of Anesthesiology, Wayne State University School of Medicine, Detroit, MI; Department of Anesthesiology, St. Joseph Mercy Oakland Hospital, Pontiac, MI
| | - Nakul Kumar
- Department of Anesthesiology, Cleveland Clinic, Cleveland, OH
| | - Vennela Reddy
- Department of Anesthesiology, Wayne State University School of Medicine, Detroit, MI; Department of Anesthesiology, St. Joseph Mercy Oakland Hospital, Pontiac, MI
| | - Joffer Hakim
- Department of Anesthesiology, Wayne State University School of Medicine, Detroit, MI; Department of Anesthesiology, St. Joseph Mercy Oakland Hospital, Pontiac, MI
| | - Sandeep H Krishnan
- Department of Anesthesiology, Wayne State University School of Medicine, Detroit, MI; Department of Anesthesiology, St. Joseph Mercy Oakland Hospital, Pontiac, MI.
| |
Collapse
|
6
|
Squara P, Scheeren TWL, Aya HD, Bakker J, Cecconi M, Einav S, Malbrain MLNG, Monnet X, Reuter DA, van der Horst ICC, Saugel B. Metrology part 1: definition of quality criteria. J Clin Monit Comput 2020; 35:17-25. [PMID: 32185615 PMCID: PMC7889530 DOI: 10.1007/s10877-020-00494-y] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2019] [Accepted: 03/04/2020] [Indexed: 11/27/2022]
Abstract
Any measurement is always afflicted with some degree of uncertainty. A correct understanding of the different types of uncertainty, their naming, and their definition is of crucial importance for an appropriate use of measuring instruments. However, in perioperative and intensive care medicine, the metrological requirements for measuring instruments are poorly defined and often used spuriously. The correct use of metrological terms is also of crucial importance in validation studies. The European Union published a new directive on medical devices, mentioning that in the case of devices with a measuring function, the notified body is involved in all aspects relating to the conformity of the device with the metrological requirements. It is therefore the task of the scientific societies to establish the standards in their area of expertise. Adopting the same understandings and definitions among clinicians and scientists is obviously the first step. In this metrologic review (part 1), we list and explain the most important terms defined by the International Bureau of Weights and Measures regarding quantities and units, properties of measurements, devices for measurement, properties of measuring devices, and measurement standards, with specific examples from perioperative and intensive care medicine.
Collapse
Affiliation(s)
- Pierre Squara
- Department of Cardiology and ICU, Clinique Ambroise Paré, Neuilly-sur-Seine, France
| | - Thomas W L Scheeren
- Department of Anesthesiology, University of Groningen, University Medical Centre Groningen, Groningen, The Netherlands.
| | - Hollmann D Aya
- Intensive Care, St Georges' University Hospitals NHS Foundation Trust, London, UK
| | - Jan Bakker
- Departmento de Medicina Intensiva, Facultad de Medicina, Pontificia Universidad Católica de Chile, Santiago, Chile.,Department of Intensive Care Adults, Erasmus MC University Medical Center, Rotterdam, The Netherlands.,Department of Pulmonary and Critical Care, New York University, New York, USA.,Division of Pulmonary, Allergy, and Critical Care Medicine, Columbia University Medical Center, New York, USA
| | - Maurizio Cecconi
- Department of Anesthesia and Critical Care, Humanitas University, Milan, Italy
| | - Sharon Einav
- General Intensive Care Unit of the Shaare Zedek Medical Centre, Hebrew University Faculty of Medicine, Jerusalem, Israel
| | - Manu L N G Malbrain
- Department of Intensive Care, University Hospital Brussels (UZB), Jette, Belgium.,Faculty of Medicine and Pharmacy, Vrije Universiteit Brussel (VUB), Brussels, Belgium
| | - Xavier Monnet
- Medical Intensive Care Unit, Paris-Sud University Hospitals, Assistance Publique-Hôpitaux de Paris, Inserm UMR S_999, Le Kremlin-Bicêtre, France
| | - Daniel A Reuter
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Rostock, Rostock, Germany
| | - Iwan C C van der Horst
- Department of Intensive Care, Maastricht University Medical Center+, Maastricht University, Maastricht, The Netherlands
| | - Bernd Saugel
- Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.,Outcomes Research Consortium, Cleveland, OH, USA
| |
Collapse
|
7
|
Grothe O, Kaplan A, Kouz K, Saugel B. Computer Program for Error Grid Analysis in Arterial Blood Pressure Method Comparison Studies. Anesth Analg 2020; 130:e71-e74. [DOI: 10.1213/ane.0000000000004584] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
8
|
Hnatkova K, Malik M. Sources of QTc variability: Implications for effective ECG monitoring in clinical practice. Ann Noninvasive Electrocardiol 2019; 25:e12730. [PMID: 31760674 PMCID: PMC7358850 DOI: 10.1111/anec.12730] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2019] [Accepted: 10/23/2019] [Indexed: 01/02/2023] Open
Abstract
Pharmaceuticals that prolong ventricular repolarization may be proarrhythmic in susceptible patients. While this fact is well recognized, schemes for sequential QTc interval monitoring in patients receiving QT‐prolonging drugs are frequently overlooked or, if implemented, underutilized in clinical practice. There are several reasons for this gap in day‐to‐day clinical practice. One of these is the perception that serially measured QTc intervals are subject to substantial variability that hampers the distinction between potential proarrhythmic signs and other sources of QTc variability. This review shows that substantial part of the QTc variability can be avoided if more accurate methodology for electrocardiogram collection, measurement, and interpretation is used. Four aspects of such a methodology are discussed. First, advanced methods for QT interval measurement are proposed including suggestion of multilead measurements in problematic recordings such as those in atrial fibrillation patients. Second, serial comparisons of T‐wave morphologies are advocated instead of simple acceptance of historical QTc measurements. Third, the necessity of understanding the pitfalls of heart rate correction is stressed including the necessity of avoiding the Bazett correction in cases of using QTc values for clinical decisions. Finally, the frequently overlooked problem of QT‐heart rate hysteresis is discussed including the possibility of gross QTc errors when correcting the QT interval for simultaneously measured short‐term heart rate.
Collapse
Affiliation(s)
| | - Marek Malik
- National Heart and Lung Institute, Imperial College, London, UK
| |
Collapse
|
9
|
Saugel B, Cecconi M, Hajjar LA. Noninvasive Cardiac Output Monitoring in Cardiothoracic Surgery Patients: Available Methods and Future Directions. J Cardiothorac Vasc Anesth 2019; 33:1742-1752. [DOI: 10.1053/j.jvca.2018.06.012] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/28/2018] [Indexed: 12/28/2022]
|
10
|
Saugel B, Grothe O, Nicklas JY. Error Grid Analysis for Arterial Pressure Method Comparison Studies. Anesth Analg 2018; 126:1177-1185. [DOI: 10.1213/ane.0000000000002585] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
|
11
|
Nguyen LS, Squara P. Non-Invasive Monitoring of Cardiac Output in Critical Care Medicine. Front Med (Lausanne) 2017; 4:200. [PMID: 29230392 PMCID: PMC5715400 DOI: 10.3389/fmed.2017.00200] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2017] [Accepted: 11/02/2017] [Indexed: 12/21/2022] Open
Abstract
Critically ill patients require close hemodynamic monitoring to titrate treatment on a regular basis. It allows administering fluid with parsimony and adjusting inotropes and vasoactive drugs when necessary. Although invasive monitoring is considered as the reference method, non-invasive monitoring presents the obvious advantage of being associated with fewer complications, at the expanse of accuracy, precision, and step-response change. A great many methods and devices are now used over the world, and this article focuses on several of them, providing with a brief review of related underlying physical principles and validation articles analysis. Reviewed methods include electrical bioimpedance and bioreactance, respiratory-derived cardiac output (CO) monitoring technique, pulse wave transit time, ultrasound CO monitoring, multimodal algorithmic estimation, and inductance thoracocardiography. Quality criteria with which devices were reviewed included: accuracy (closeness of agreement between a measurement value and a true value of the measured), precision (closeness of agreement between replicate measurements on the same or similar objects under specified conditions), and step response change (delay between physiological change and its indication). Our conclusion is that the offer of non-invasive monitoring has improved in the past few years, even though further developments are needed to provide clinicians with sufficiently accurate devices for routine use, as alternative to invasive monitoring devices.
Collapse
Affiliation(s)
- Lee S Nguyen
- Critical Care Medicine Department, CMC Ambroise Paré, Neuilly-sur-Seine, France
| | - Pierre Squara
- Critical Care Medicine Department, CMC Ambroise Paré, Neuilly-sur-Seine, France
| |
Collapse
|
12
|
Zeng R, Svensen CH, Li H, Xu X, Skoog Svanberg A, Liu H, Li Y, Shangguan W, Lian Q. Can noninvasive hemoglobin measurement reduce the need for preoperative venipuncture in pediatric outpatient surgery? Paediatr Anaesth 2017; 27:1131-1135. [PMID: 28940988 DOI: 10.1111/pan.13229] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 07/30/2017] [Indexed: 11/26/2022]
Abstract
BACKGROUND Noninvasive measurements of hemoglobin in the pediatric perioperative setting could be helpful to avoid venipunctures in children. The present study aims to evaluate this by using a noninvasive device for hemoglobin determination. We compared noninvasively obtained hemoglobin with laboratory hemoglobin concentrations in children during their preoperative assessment. METHODS In an observational study, 122 nonanemic children (age 4.2 ± 1.6 years) who were scheduled to undergo different surgical procedures under general anesthesia were included. In their preoperative preparations, single invasive blood samples for laboratory hemoglobin concentrations were routinely taken following hospital policy and compared to simultaneous noninvasive determinations of hemoglobin. A preoperative invasive value ≤9 g/dL would have caused cancelation of surgery and implied further investigations. RESULTS A Bland-Altman plot showed that the average difference between noninvasively obtained hemoglobin and laboratory hemoglobin concentration was -0.44 g/dL (bias) with a standard deviation of the mean bias of 1.04 g/dL. A hemoglobin error grid showed that the noninvasive device could identify almost all invasive hemoglobin values >9 g/dL. In total, there were 4 false-positive values where noninvasively obtained hemoglobin observations were below while the paired invasive values were above 9 g/dL. CONCLUSION The data in this pediatric setting suggest that the device may eliminate the need for venipuncture in nonanemic children.
Collapse
Affiliation(s)
- Ruifeng Zeng
- Department of Anesthesiology, The Second Affiliated Hospital and Yuying Children's Hospital, Wenzhou Medical University, Wenzhou, China
| | - Christer H Svensen
- Department of Anesthesiology, The Second Affiliated Hospital and Yuying Children's Hospital, Wenzhou Medical University, Wenzhou, China.,Department of Clinical Science and Education, Section of Anesthesiology and Intensive Care, Karolinska Institutet, Stockholm, Sweden.,Department of Anesthesiology, University of Texas Medical Branch, UTMB Health, Galveston, TX, USA
| | - Husong Li
- Department of Anesthesiology, The Second Affiliated Hospital and Yuying Children's Hospital, Wenzhou Medical University, Wenzhou, China.,Department of Anesthesiology, University of Texas Medical Branch, UTMB Health, Galveston, TX, USA
| | - Ximou Xu
- Department of Anesthesiology, The Second Affiliated Hospital and Yuying Children's Hospital, Wenzhou Medical University, Wenzhou, China
| | | | - Huacheng Liu
- Department of Anesthesiology, The Second Affiliated Hospital and Yuying Children's Hospital, Wenzhou Medical University, Wenzhou, China
| | - Yanrong Li
- Department of Anesthesiology, The Second Affiliated Hospital and Yuying Children's Hospital, Wenzhou Medical University, Wenzhou, China
| | - Wangning Shangguan
- Department of Anesthesiology, The Second Affiliated Hospital and Yuying Children's Hospital, Wenzhou Medical University, Wenzhou, China
| | - Qingquan Lian
- Department of Anesthesiology, The Second Affiliated Hospital and Yuying Children's Hospital, Wenzhou Medical University, Wenzhou, China
| |
Collapse
|
13
|
Predicting Fluid Responsiveness in Critically Ill Patients by Using Combined End-Expiratory and End-Inspiratory Occlusions With Echocardiography. Crit Care Med 2017; 45:e1131-e1138. [DOI: 10.1097/ccm.0000000000002704] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
14
|
Odor PM, Bampoe S, Cecconi M. Cardiac Output Monitoring: Validation Studies-how Results Should be Presented. CURRENT ANESTHESIOLOGY REPORTS 2017; 7:410-415. [PMID: 29200975 PMCID: PMC5696446 DOI: 10.1007/s40140-017-0239-0] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Purpose of Review Cardiac output monitors can be assessed by a variety of techniques, but a common principle is quantifying agreement between a reference standard and new monitor. The current standard analysis technique is a Bland-Altman plot. The Bland-Altman plot evaluates bias between mean differences of cardiac output, from which an agreement interval is derived. These limits are, however, statistical limits of agreement and the clinical acceptability will depend upon context and application. This article provides suggestions for understanding and presenting the results of cardiac output validation, using standard metrology alongside proposals for criteria used to accept new techniques. Recent Findings Confusion about the appropriate way to report “precision” in method comparison studies stem from a lack of clarity on how single or repeated measurements should be interpreted. During serial measurements of cardiac output the true value changes, thus measurement should be considered as serial rather than repeated. Method agreement based upon precision achieved by cardiac output monitors needs to consider each method’s general variability around true values obtained and this data should be generated and presented as part of each study design. Summary Studies should report serial measurements from two techniques for cardiac output monitoring. Results of similar techniques from other studies may not always be transferred and compared. Bias and intervals of agreement should be presented as Bland-Altman plots with dynamic cardiac output trends in polar plots. Percentage error should be calculated to allow appropriate comparison of techniques for study populations with different expected cardiac output values.
Collapse
Affiliation(s)
- Peter M Odor
- Department of Anaesthesia, St. George's University Hospital, London, SW17 0QT UK
| | - Sohail Bampoe
- Centre for Perioperative Medicine, University College London, London, UK.,Department of Anaesthesia and Perioperative Medicine, University College Hospital, London, UK
| | - Maurizio Cecconi
- Department of Anaesthesia and Intensive Care, St. George's University Hospital, London, UK
| |
Collapse
|
15
|
Kumar A, Tanaka Y, Grigoriadis A, Grigoriadis J, Trulsson M, Svensson P. Training-induced dynamics of accuracy and precision in human motor control. Sci Rep 2017; 7:6784. [PMID: 28754929 PMCID: PMC5533741 DOI: 10.1038/s41598-017-07078-y] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2017] [Accepted: 06/22/2017] [Indexed: 11/24/2022] Open
Abstract
The study investigated the dynamic changes in accuracy and precision during a simple oral and digital motor task involving a controlled and a ballistic force. Eighteen healthy participants participated in four experimental sessions during which they performed one hundred trials of targeting a controlled (low/high hold force) and a ballistic force during an oral and a digital motor task (OMT and DMT). Accuracy and precision across one hundred trials were calculated and subjected to segmented linear regression analysis. Repeated performance of controlled forces show a significant dynamic change in accuracy during initial stage of targeting high hold forces during OMT and a significant dynamic change in both accuracy and precision during final stage of targeting high hold forces during DMT. Repeated performance of ballistic force showed a significant dynamic change in both accuracy and precision during final stage of targeting high hold force forces during OMT and a significant dynamic change in accuracy during the initial stages of targeting high hold force during the DMT. The findings indicate a subtle degree of dissociation between accuracy and precision in terms of dynamic modulation of forces due to repeated performance of both OMT and DMT.
Collapse
Affiliation(s)
- Abhishek Kumar
- Section of Oral Rehabilitation, Department of Dental Medicine, Karolinska Institutet, Huddinge, Sweden.
- SCON| Scandinavian Center for Orofacial Neurosciences, Huddinge, Sweden.
| | - Yuto Tanaka
- Department of Dentistry for Disability and Oral Health, Osaka Dental University Hospital, Osaka, Japan
| | - Anastasios Grigoriadis
- Section of Oral Rehabilitation, Department of Dental Medicine, Karolinska Institutet, Huddinge, Sweden
- SCON| Scandinavian Center for Orofacial Neurosciences, Huddinge, Sweden
| | - Joannis Grigoriadis
- Section of Oral Rehabilitation, Department of Dental Medicine, Karolinska Institutet, Huddinge, Sweden
- SCON| Scandinavian Center for Orofacial Neurosciences, Huddinge, Sweden
| | - Mats Trulsson
- Section of Oral Rehabilitation, Department of Dental Medicine, Karolinska Institutet, Huddinge, Sweden
- SCON| Scandinavian Center for Orofacial Neurosciences, Huddinge, Sweden
| | - Peter Svensson
- Section of Oral Rehabilitation, Department of Dental Medicine, Karolinska Institutet, Huddinge, Sweden
- Section of Orofacial Pain and Jaw Function, Institute of Odontology and Oral Health, Aarhus University, Aarhus, Denmark
- SCON| Scandinavian Center for Orofacial Neurosciences, Huddinge, Sweden
| |
Collapse
|
16
|
Gurbeta L, Dzemic Z, Bego T, Sejdic E, Badnjevic A. Testing of Anesthesia Machines and Defibrillators in Healthcare Institutions. J Med Syst 2017; 41:133. [PMID: 28752483 DOI: 10.1007/s10916-017-0783-7] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2017] [Accepted: 07/19/2017] [Indexed: 11/29/2022]
Abstract
To improve the quality of patient treatment by improving the functionality of medical devices in healthcare institutions. To present the results of the safety and performance inspection of patient-relevant output parameters of anesthesia machines and defibrillators defined by legal metrology. This study covered 130 anesthesia machines and 161 defibrillators used in public and private healthcare institutions, during a period of two years. Testing procedures were carried out according to international standards and legal metrology legislative procedures in Bosnia and Herzegovina. The results show that in 13.84% of tested anesthesia machine and 14.91% of defibrillators device performance is not in accordance with requirements and should either have its results be verified, or the device removed from use or scheduled for corrective maintenance. Research emphasizes importance of independent safety and performance inspections, and gives recommendations for the frequency of inspection based on measurements. Results offer implications for adequacy of preventive and corrective maintenance performed in healthcare institutions. Based on collected data, the first digital electronical database of anesthesia machines and defibrillators used in healthcare institutions in Bosnia and Herzegovina is created. This database is a useful tool for tracking each device's performance over time.
Collapse
Affiliation(s)
- Lejla Gurbeta
- Verlab Ltd Sarajevo, Bosnia and Herzegovina, Ismeta Mujezinovica 30, Sarajevo, Bosnia and Herzegovina.,Faculty of Engineering and IT, International Burch University, Francuske revolucije bb, Sarajevo, Bosnia and Herzegovina
| | - Zijad Dzemic
- Institute of Metrology of Bosnia and Herzegovina, Augusta Brauna 2, Sarajevo, Bosnia and Herzegovina
| | - Tamer Bego
- Faculty of Pharmacy, University of Sarajevo, Zmaja od Bosne 8, Sarajevo, Bosnia and Herzegovina
| | - Ervin Sejdic
- Department and Electrical and Computer Engineering, Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, USA, 3700 O'Hara Street, Benedum Hall of Engineering, Pittsburgh, PA, 15261, USA
| | - Almir Badnjevic
- Verlab Ltd Sarajevo, Bosnia and Herzegovina, Ismeta Mujezinovica 30, Sarajevo, Bosnia and Herzegovina. .,Faculty of Engineering and IT, International Burch University, Francuske revolucije bb, Sarajevo, Bosnia and Herzegovina. .,Technical Faculty Bihac, University of Bihac, Bosnia and Herzegovina, dr. Irfana Ljubijankića bb, Bihać, Bosnia and Herzegovina.
| |
Collapse
|
17
|
Saugel B, Michard F, Scheeren TWL. Goal-directed therapy: hit early and personalize! J Clin Monit Comput 2017; 32:375-377. [PMID: 28653134 DOI: 10.1007/s10877-017-0043-x] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2017] [Accepted: 06/22/2017] [Indexed: 01/22/2023]
Affiliation(s)
- Bernd Saugel
- Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.
| | | | - Thomas W L Scheeren
- Department of Anesthesiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands
| |
Collapse
|
18
|
Souto Moura T, Aguiar Rosa S, Germano N, Cavaco R, Sequeira T, Alves M, Papoila AL, Bento L. The accuracy of PiCCO® in measuring cardiac output in patients under therapeutic hypothermia: Comparison with transthoracic echocardiography. Med Intensiva 2017; 42:92-98. [PMID: 28552462 DOI: 10.1016/j.medin.2017.03.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2016] [Revised: 01/30/2017] [Accepted: 03/17/2017] [Indexed: 12/01/2022]
Abstract
BACKGROUND Invasive cardiac monitoring using thermodilution methods such as PiCCO® is widely used in critically ill patients and provides a wide range of hemodynamic variables, including cardiac output (CO). However, in post-cardiac arrest patients subjected to therapeutic hypothermia, the low body temperature possibly could interfere with the technique. Transthoracic Doppler echocardiography (ECHO) has long proved its accuracy in estimating CO, and is not influenced by temperature changes. OBJECTIVE To assess the accuracy of PiCCO® in measuring CO in patients under therapeutic hypothermia, compared with ECHO. DESIGN AND PATIENTS Thirty paired COECHO/COPiCCO measurements were analyzed in 15 patients subjected to hypothermia after cardiac arrest. Eighteen paired measurements were obtained at under 36°C and 12 at ≥36°C. A value of 0.5l/min was considered the maximum accepted difference between the COECHO and COPiCCO values. RESULTS Under conditions of normothermia (≥36°C), the mean difference between COECHO and COPiCCO was 0.030 l/min, with limits of agreement (-0.22, 0.28) - all of the measurements differing by less than 0.5 l/min. In situations of hypothermia (<36°C), the mean difference in CO measurements was -0.426 l/min, with limits of agreement (-1.60, 0.75), and only 44% (8/18) of the paired measurements fell within the interval (-0.5, 0.5). The calculated temperature cut-off point maximizing specificity was 35.95°C: above this temperature, specificity was 100%, with a false-positive rate of 0%. CONCLUSIONS The results clearly show clinically relevant discordance between COECHO and COPiCCO at temperatures of <36°C, demonstrating the inaccuracy of PiCCO® for cardiac output measurements in hypothermic patients.
Collapse
Affiliation(s)
- T Souto Moura
- Medicine Department 1, 4 São José's Hospital, Central Lisbon Hospitalar Centre, Portugal.
| | - S Aguiar Rosa
- Cardiology Department, Santa Marta's Hospital, Central Lisbon Hospitalar Centre, Portugal
| | - N Germano
- Medical Urgency Unit, São José's Hospital, Central Lisbon Hospitalar Centre, Portugal
| | - R Cavaco
- Medical Urgency Unit, São José's Hospital, Central Lisbon Hospitalar Centre, Portugal
| | - T Sequeira
- Medical Urgency Unit, São José's Hospital, Central Lisbon Hospitalar Centre, Portugal
| | - M Alves
- Epidemiological and Statistical Analysis Department, Investigation Center of the Central Lisbon Hospitalar Centre, Portugal
| | - A L Papoila
- Epidemiological and Statistical Analysis Department, Investigation Center of the Central Lisbon Hospitalar Centre, Portugal; Statistical and Applications Center of NOVA Medical School, Portugal
| | - L Bento
- Medical Urgency Unit, São José's Hospital, Central Lisbon Hospitalar Centre, Portugal
| |
Collapse
|
19
|
Sander CH, Sigmundsson T, Hallbäck M, Sipmann FS, Wallin M, Oldner A, Björne H. A modified breathing pattern improves the performance of a continuous capnodynamic method for estimation of effective pulmonary blood flow. J Clin Monit Comput 2016; 31:717-725. [PMID: 27251701 DOI: 10.1007/s10877-016-9891-z] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2016] [Accepted: 05/25/2016] [Indexed: 12/15/2022]
Abstract
In a previous study a new capnodynamic method for estimation of effective pulmonary blood flow (COEPBF) presented a good trending ability but a poor agreement with a reference cardiac output (CO) measurement at high levels of PEEP. In this study we aimed at evaluating the agreement and trending ability of a modified COEPBF algorithm that uses expiratory instead of inspiratory holds during CO and ventilatory manipulations. COEPBF was evaluated in a porcine model at different PEEP levels, tidal volumes and CO manipulations (N = 8). An ultrasonic flow probe placed around the pulmonary trunk was used for CO measurement. We tested the COEPBF algorithm using a modified breathing pattern that introduces cyclic end-expiratory time pauses. The subsequent changes in mean alveolar fraction of carbon dioxide were integrated into a capnodynamic equation and effective pulmonary blood flow, i.e. non-shunted CO, was calculated continuously breath by breath. The overall agreement between COEPBF and the reference method during all interventions was good with bias (limits of agreement) 0.05 (-1.1 to 1.2) L/min and percentage error of 36 %. The overall trending ability as assessed by the four-quadrant and the polar plot methodology was high with a concordance rate of 93 and 94 % respectively. The mean polar angle was 0.4 (95 % CI -3.7 to 4.5)°. A ventilatory pattern recurrently introducing end-expiratory pauses maintains a good agreement between COEPBF and the reference CO method while preserving its trending ability during CO and ventilatory alterations.
Collapse
Affiliation(s)
- Caroline Hällsjö Sander
- Department of Anaesthesiology, Surgical Services and Intensive Care Medicine, Karolinska University Hospital, 171 76, Solna, Stockholm, Sweden. .,Department of Physiology and Pharmacology, Karolinska Institutet, Stockholm, Sweden.
| | - Thorir Sigmundsson
- Department of Anaesthesiology, Surgical Services and Intensive Care Medicine, Karolinska University Hospital, 171 76, Solna, Stockholm, Sweden.,Department of Physiology and Pharmacology, Karolinska Institutet, Stockholm, Sweden
| | | | - Fernando Suarez Sipmann
- Hedenstierna's Laboratory, Department of Surgical Sciences, Section of Anaesthesiology and Critical Care, Uppsala University, Uppsala, Sweden.,CIBER de enfermedades respiratorias (CIBERES), Instituto Carlos III, Madrid, Spain
| | - Mats Wallin
- Department of Physiology and Pharmacology, Karolinska Institutet, Stockholm, Sweden.,Maquet Critical Care AB, Solna, Sweden
| | - Anders Oldner
- Department of Anaesthesiology, Surgical Services and Intensive Care Medicine, Karolinska University Hospital, 171 76, Solna, Stockholm, Sweden.,Department of Physiology and Pharmacology, Karolinska Institutet, Stockholm, Sweden
| | - Håkan Björne
- Department of Anaesthesiology, Surgical Services and Intensive Care Medicine, Karolinska University Hospital, 171 76, Solna, Stockholm, Sweden.,Department of Physiology and Pharmacology, Karolinska Institutet, Stockholm, Sweden
| |
Collapse
|
20
|
Saugel B, Wagner J, Reuter D. Haemodynamic monitoring: the inseparable relation of accuracy and trending. Br J Anaesth 2015; 115:943. [DOI: 10.1093/bja/aev391] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
21
|
Cardiac output method comparison studies: the relation of the precision of agreement and the precision of method. J Clin Monit Comput 2015; 30:149-55. [DOI: 10.1007/s10877-015-9711-x] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2015] [Accepted: 05/26/2015] [Indexed: 10/23/2022]
|