Evrard R, Feyens M, Manon J, Lengelé B, Cartiaux O, Schubert T. Impact of NaOH based perfusion-decellularization protocol on mechanical resistance of structural bone allografts. Connect Tissue Res 2024:1-14. [PMID: 38781097 DOI: 10.1080/03008207.2024.2356586] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Accepted: 05/13/2024] [Indexed: 05/25/2024]
Abstract
INTRODUCTION To mitigate the post-operative complication rates associated with massive bone allografts, tissue engineering techniques have been employed to decellularize entire bones through perfusion with a sequence of solvents. Mechanical assessment was performed in order to compare conventional massive bone allografts and perfusion/decellularized massive bone allografts. MATERIAL AND METHODS Ten porcine femurs were included. Five were decellularized by perfusion. The remaining 5 were left untreated as the "control" group. Biomechanical testing was conducted on each bone, encompassing five different assessments: screw pull-out, 3-points bending, torsion, compression and Vickers indentation. RESULTS Under the experimental conditions of this study, all five destructive tested variables (maximum force until screw pull-out, maximum elongation until screw pull-out, energy to pull out the screw, fracture resistance in flexion and maximum constrain of compression) were statistically significantly superior in the control group. All seven nondestructive variables (Young's modulus in flexion, Young's modulus in shear stress, Young's modulus in compression, Elastic conventional limit in compression, lengthening to rupture in compression, resilience in compression and Vickers Hardness) showed no significant difference. DISCUSSION Descriptive statistical results suggest a tendency for the biomechanical characteristics of decellularized bone to decrease compared with the control group. However, statistical inferences demonstrated a slight significant superiority of the control group with destructive mechanical stresses. Nondestructive mechanical tests (within the elastic phase of Young's modulus) were not significantly different.
Collapse
Affiliation(s)
- Robin Evrard
- Institut de Recherche Expérimentale et Clinique, Neuro Musculo-Skeletal Lab, Université Catholique de Louvain, Bruxelles, Belgique
- Institut de Recherche Expérimentale et Clinique, Pôle Chirurgie Expérimentale et Transplantation, Université Catholique de Louvain, Bruxelles, Belgique
- Service de Chirurgie Orthopédique et Traumatologique, Cliniques Universitaires Saint-Luc, Bruxelles, Belgique
| | - Maxendre Feyens
- ECAM Brussels Engineering School, Haute Ecole ICHEC-ECAM-ISFSC, Bruxelles, Belgique
| | - Julie Manon
- Institut de Recherche Expérimentale et Clinique, Neuro Musculo-Skeletal Lab, Université Catholique de Louvain, Bruxelles, Belgique
- Service de Chirurgie Orthopédique et Traumatologique, Cliniques Universitaires Saint-Luc, Bruxelles, Belgique
- Institut de Recherche Expérimentale et Clinique, Pôle Morphologie, Université Catholique de Louvain, Bruxelles, Belgique
| | - Benoit Lengelé
- Institut de Recherche Expérimentale et Clinique, Pôle Morphologie, Université Catholique de Louvain, Bruxelles, Belgique
- Service de Chirurgie Plastique, Reconstructrice et Esthétique, Cliniques Universitaires Saint-Luc, Bruxelles, Belgique
| | - Olivier Cartiaux
- ECAM Brussels Engineering School, Haute Ecole ICHEC-ECAM-ISFSC, Bruxelles, Belgique
| | - Thomas Schubert
- Institut de Recherche Expérimentale et Clinique, Neuro Musculo-Skeletal Lab, Université Catholique de Louvain, Bruxelles, Belgique
- Service de Chirurgie Orthopédique et Traumatologique, Cliniques Universitaires Saint-Luc, Bruxelles, Belgique
| |
Collapse
|
2
|
Zdero R, Brzozowski P, Schemitsch EH. Biomechanical properties of artificial bones made by Sawbones: A review. Med Eng Phys 2023; 118:104017. [PMID: 37536838 DOI: 10.1016/j.medengphy.2023.104017] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 06/23/2023] [Accepted: 06/27/2023] [Indexed: 08/05/2023]
Abstract
Biomedical engineers and physicists frequently use human or animal bone for orthopaedic biomechanics research because they are excellent approximations of living bone. But, there are drawbacks to biological bone, like degradation over time, ethical concerns, high financial costs, inter-specimen variability, storage requirements, supplier sourcing, transportation rules, etc. Consequently, since the late 1980s, the Sawbones® company has been one of the world's largest suppliers of artificial bones for biomechanical testing that counteract many disadvantages of biological bone. There have been many published reports using these bone analogs for research on joint replacement, bone fracture fixation, spine surgery, etc. But, there exists no prior review paper on these artificial bones that gives a comprehensive and in-depth look at the numerical data of interest to biomedical engineers and physicists. Thus, this paper critically reviews 25 years of English-language studies on the biomechanical properties of these artificial bones that (a) characterized unknown or unreported values, (b) validated them against biological bone, and/or (c) optimized different design parameters. This survey of data, advantages, disadvantages, and knowledge gaps will hopefully be useful to biomedical engineers and physicists in developing mechanical testing protocols and computational finite element models.
Collapse
Affiliation(s)
- Radovan Zdero
- Orthopaedic Biomechanics Lab, Victoria Hospital, London, ON, Canada
| | - Pawel Brzozowski
- Orthopaedic Biomechanics Lab, Victoria Hospital, London, ON, Canada.
| | - Emil H Schemitsch
- Orthopaedic Biomechanics Lab, Victoria Hospital, London, ON, Canada; Division of Orthopaedic Surgery, Western University, London, ON, Canada
| |
Collapse
|
3
|
Decellularized vascularized bone grafts as therapeutic solution for bone reconstruction: A mechanical evaluation. PLoS One 2023; 18:e0280193. [PMID: 36638107 PMCID: PMC9838862 DOI: 10.1371/journal.pone.0280193] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Accepted: 12/22/2022] [Indexed: 01/14/2023] Open
Abstract
INTRODUCTION Large bone defects are challenging for surgeons. Available reimplanted bone substitutes can't properly restore optimal function along and long term osteointegration of the bone graft. Bone substitute based on the perfusion-decellularization technique seem to be interesting in order to overcome these limitations. We present here an evaluation of the biomechanics of the bones thus obtained. MATERIAL AND METHODS Two decellularization protocols were chosen for this study. One using Sodium Dodecyl Sulfate (SDS) (D1) and one using NaOH and H2O2 (D2). The decellularization was performed on porcine forearms. We then carried out compression, three-point bending, indentation and screw pull-out tests on each sample. Once these tests were completed, we compared the results obtained between the different decellularization protocols and with samples left native. RESULTS The difference in the means was similar between the tests performed on bones decellularized with the SDS protocol and native bones for pull-out test: +1.4% (CI95% [-10.5%- 12.4%]) of mean differences when comparing Native vs D1, compression -14.9% (CI95% [-42.7%- 12.5%]), 3-point bending -5.7% (CI95% [-22.5%- 11.1%]) and indentation -10.8% (CI95% [-19.5%- 4.6%]). Bones decellularized with the NaOH protocol showed different results from those obtained with the SDS protocol or native bones during the pull-out screw +40.7% (CI95% [24.3%- 57%]) for Native vs D2 protocol and 3-point bending tests +39.2% (CI95% [13.7%- 64.6%]) for Native vs D2 protocol. The other tests, compression and indentation, gave similar results for all our samples. CONCLUSION Vascularized decellularized grafts seem to be an interesting means for bone reconstruction. Our study shows that the decellularization method affects the mechanical results of our specimens. Some methods seem to limit these alterations and could be used in the future for bone decellularization.
Collapse
|
4
|
Stewart AJ, Miles AW, Fletcher JWA. Influence of pilot hole diameter in cancellous screw fixation in a reduced density animal bone model. Clin Biomech (Bristol, Avon) 2020; 80:105152. [PMID: 32866854 DOI: 10.1016/j.clinbiomech.2020.105152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Revised: 08/07/2020] [Accepted: 08/13/2020] [Indexed: 02/07/2023]
Abstract
BACKGROUND Screw fixation in osteoporotic bone is clinically challenging. Screw failure rates are growing due to an increasing prevalence of osteoporosis. To address this, biomechanical models are needed to recreate the bone clinically encountered alongside the development of new operative techniques. The first aim of this study was to test whether the use of a smaller than recommended pilot-hole diameter improved pull-out strength for cancellous screws, with the second aim to create a model of low-density porcine bone for biomechanical testing. METHODS Thirty porcine tibiae were cut into transverse metaphyseal sections of 20 mm thickness. Bone density was altered using 0.15 M Hydrochloric acid, and measured and pre- and post-demineralisation using HRμCT. Seventy-two screw areas were randomised to either 2.5 mm or 1.5 mm pilot holes and to either be normal or reduced density. Maximum axial pull-out strength was measured. FINDINGS Demineralisation reduced bone density by 12% (p < 0.0001) and 11% (p < 0.0001) for 2.5 mm and 1.5 mm pilot hole diameters respectively. Pull-out strength reduced by 50% (p = 0.0001) and 44% (p < 0.0001) following demineralisation for both 2.5 mm and 1.5 mm pilot hole diameters. Pull-out strength increased by 51% (p = 0.0008) when inserting screws into 1.5 mm pilot holes in low density bone, and by 28% (p = 0.027) in normal bone. INTERPRETATION Porcine bone can be demineralised to model low density cancellous bone. This novel model showed that pullout force is significantly reduced in lower density screw holes, but that this reduction can be mitigated by reducing pilot hole diameter for cancellous screws.
Collapse
Affiliation(s)
| | - Anthony W Miles
- Department of Mechanical Engineering, University of Bath, UK.
| | | |
Collapse
|
5
|
Testing Pullout Strength of Pedicle Screw Using Synthetic Bone Models: Is a Bilayer Foam Model a Better Representation of Vertebra? Asian Spine J 2018; 12:398-406. [PMID: 29879765 PMCID: PMC6002167 DOI: 10.4184/asj.2018.12.3.398] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2017] [Revised: 11/04/2017] [Accepted: 11/15/2017] [Indexed: 12/04/2022] Open
Abstract
Study Design A biomechanical study. Purpose A new biomechanical model of the vertebra has been developed that accounts for the inhomogeneity of bone and the contribution of the pedicle toward the holding strength of a pedicle screw. Overview of Literature Pullout strength studies are typically carried out on rigid polyurethane foams that represent the homogeneous vertebral framework of the spine. However, the contribution of the pedicle region, which contributes to the inhomogeneity in this framework, has not been considered in previous investigations. Therefore, we propose a new biomechanical model that can account for the vertebral inhomogeneity, especially the contribution of the pedicles toward the pullout strength of the pedicle screw. Methods A bilayer foam model was developed by joining two foams representing the pedicle and the vertebra. The results of the pullout strength tests performed on the foam models were compared with those from the tests performed on the cadaver lumbar vertebra. Results Significant differences (p <0.05) were observed between the pullout strength of the pedicle screw in extremely osteoporotic (0.18±0.11 kN), osteoporotic (0.37±0.14 kN), and normal (0.97±0.4 kN) cadaver vertebra. In the monolayer model, significant differences (p <0.05) were observed in pullout strength between extremely osteoporotic (0.3±0.02 kN), osteoporotic (0.65±0.12 kN), and normal (0.99±0.04 kN) bone model. However, the bilayer foam model exhibited no significant differences (p >0.05) in the pullout strength of pedicle screws between osteoporotic (0.85±0.08 kN) and extremely osteoporotic bone models (0.94±0.08 kN), but there was a significant difference (p <0.05) between osteoporotic (0.94±0.08 kN) and normal bone models (1.19±0.05 kN). There were no significant differences (p >0.05) in pullout strength between cadaver and bilayer foam model in normal bones. Conclusions The new synthetic bone model that reflects the contribution of the pedicles to the pullout strength of the pedicle screws could provide a more efficacious means of testing pedicle-screw pullout strength. The bilayer model can match the pullout strength value of normal lumbar vertebra bone whereas the monolayer foam model was able to match that of the extremely osteoporotic lumbar vertebra.
Collapse
|
6
|
Increased torsional stability by a novel femoral neck locking plate. The role of plate design and pin configuration in a synthetic bone block model. Clin Biomech (Bristol, Avon) 2018; 55:28-35. [PMID: 29653317 DOI: 10.1016/j.clinbiomech.2018.03.024] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2017] [Revised: 03/23/2018] [Accepted: 03/26/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND In undisplaced femoral neck fractures, internal fixation remains the main treatment, with mechanical failure as a frequent complication. As torsional stable fixation promotes femoral neck fracture healing, the Hansson Pinloc® System with a plate interlocking pins, was developed from the original hook pins. Since its effect on torsional stability is undocumented, the novel implant was compared with the original configurations. METHODS Forty-two proximal femur models custom made of two blocks of polyurethane foam were tested. The medial block simulated the cancellous head, while the lateral was laminated with a glass fiber filled epoxy sheet simulating trochanteric cortical bone. Two hollow metal cylinders with a circumferential ball bearing in between mimicked the neck, with a perpendicular fracture in the middle. Fractures were fixated by two or three independent pins or by five configurations involving the interlocking plate (two pins with an optional peg in a small plate, or three pins in a small, medium or large plate). Six torsional tests were performed on each configuration to calculate torsional stiffness, torque at failure and failure energy. FINDINGS The novel configurations improved parameters up to an average of 12.0 (stiffness), 19.3 (torque) and 19.9 (energy) times higher than the original two pins (P < 0.001). The plate, its size and its triangular configuration improved all parameters (P = 0.03), the plate being most effective, also preventing permanent failure (P < 0.001). INTERPRETATION The novel plate design with its pin configuration enhanced torsional stability. To reveal clinical relevance a clinical study is planned.
Collapse
|
7
|
MacAvelia T, Salahi M, Olsen M, Crookshank M, Schemitsch EH, Ghasempoor A, Janabi-Sharifi F, Zdero R. Biomechanical Measurements of Surgical Drilling Force and Torque in Human Versus Artificial Femurs. J Biomech Eng 2012; 134:124503. [DOI: 10.1115/1.4007953] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Few experimental studies have examined surgical drilling in human bone, and no studies have inquired into this aspect for a popular commercially-available artificial bone used in biomechanical studies. Sixteen fresh-frozen human femurs and five artificial femurs were obtained. Cortical specimens were mounted into a clamping system equipped with a thrust force and torque transducer. Using a CNC machine, unicortical holes were drilled in each specimen at 1000 rpm, 1250 rpm, and 1500 rpm with a 3.2 mm diameter surgical drill bit. Feed rate was 120 mm/min. Statistical significance was set at p < 0.05. Force at increasing spindle speed (1000 rpm, 1250 rpm, and 1500 rpm), respectively, showed a range for human femurs (198.4 ± 14.2 N, 180.6 ± 14.0 N, and 176.3 ± 11.2 N) and artificial femurs (87.2 ± 19.3 N, 82.2 ± 11.2 N, and 75.7 ± 8.8 N). For human femurs, force at 1000 rpm was greater than at other speeds (p ≤ 0.018). For artificial femurs, there was no speed effect on force (p ≥ 0.991). Torque at increasing spindle speed (1000 rpm, 1250 rpm, and 1500 rpm), respectively, showed a range for human femurs (186.3 ± 16.9 N·mm, 157.8 ± 16.1 N·mm, and 140.2 ± 16.4 N·mm) and artificial femurs (67.2 ± 8.4 N·mm, 61.0 ± 2.9 N·mm, and 53.3 ± 2.9 N·mm). For human femurs, torque at 1000 rpm was greater than at other speeds (p < 0.001). For artificial femurs, there was no difference in torque for 1000 rpm versus higher speeds (p ≥ 0.228), and there was only a borderline difference between the higher speeds (p = 0.046). Concerning human versus artificial femurs, their behavior was different at every speed (force, p ≤ 0.001; torque, p < 0.001). For human specimens at 1500 rpm, force and torque were linearly correlated with standardized bone mineral density (sBMD) and the T-score used to clinically categorize bone quality (R ≥ 0.56), but there was poor correlation with age at all speeds (R ≤ 0.37). These artificial bones fail to replicate force and torque in human cortical bone during surgical drilling. To date, this is the largest series of human long bones biomechanically tested for surgical drilling.
Collapse
Affiliation(s)
| | - Meisam Salahi
- Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, ON, M5B 2K3, Canada
| | | | | | - Emil H. Schemitsch
- Martin Orthopaedic Biomechanics Laboratory, St. Michael's Hospital, Toronto, ON, M5B 1W8, Canada; Department of Surgery, University of Toronto, Toronto, ON, M5G 1L5, Canada
| | | | - Farrokh Janabi-Sharifi
- Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, ON, M5B 2K3, Canada
| | - Rad Zdero
- Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, ON, M5B 2K3, Canada; Martin Orthopaedic Biomechanics Laboratory, St. Michael's Hospital, Toronto, ON, M5B 1W8, Canada e-mail:
| |
Collapse
|
8
|
Crookshank M, Coquim J, Olsen M, Schemitsch EH, Bougherara H, Zdero R. Biomechanical measurements of axial crush injury to the distal condyles of human and synthetic femurs. Proc Inst Mech Eng H 2012; 226:320-9. [DOI: 10.1177/0954411912438038] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Few studies have evaluated the ‘bulk’ mechanical properties of human longbones and even fewer have compared human tissue to the synthetic longbones increasingly being used by researchers. Distal femur fractures, for example, comprise about 6% of all femur fractures, but the mechanical properties of the distal condyles of intact human and synthetic femurs have not been well quantified in the literature. To this end, the distal portions of a series of 16 human fresh-frozen femurs and six synthetic femurs were prepared identically for mechanical testing. Using a flat metal plate, an axial ‘crush’ force was applied in-line with the long axis of the femurs. The two femur groups were statistically compared and values correlated to age, size, and bone quality. Results yielded the following: crush stiffness (human, 1545 ± 728 N/mm; synthetic, 3063 ± 1243 N/mm; p = 0.002); crush strength (human, 10.3 ± 3.1 kN; synthetic, 12.9 ± 1.7 kN; p = 0.074); crush displacement (human, 6.1 ± 1.8 mm; synthetic, 2.8 ± 0.3 mm; p = 0.000); and crush energy (human, 34.8 ± 15.9 J; synthetic, 18.1 ± 5.7 J; p = 0.023). For the human femurs, there were poor correlations between mechanical properties versus age, size, and bone quality (R2 ≤ 0.18), with the exception of crush strength versus bone mineral density (R2 = 0.33) and T-score (R2 = 0.25). Human femurs failed mostly by condyle ‘roll back’ buckling (15 of 16 cases) and/or unicondylar or bicondylar fracture (7 of 16 cases), while synthetic femurs all failed by wedging apart of the condyles resulting in either fully or partially displaced condylar fractures (6 of 6 cases). These findings have practical implications on the use of a flat plate load applicator to reproduce real-life clinical failure modes of human femurs and the appropriate use of synthetic femurs. To the authors’ knowledge, this is the first study to have done such an assessment on human and synthetic femurs.
Collapse
Affiliation(s)
- Meghan Crookshank
- Faculty of Medicine, University of Toronto, Canada
- Martin Orthopaedic Biomechanics Laboratory, St Michael’s Hospital, Canada
| | - Jason Coquim
- Department of Mechanical and Industrial Engineering, Ryerson University, Canada
| | - Michael Olsen
- Faculty of Medicine, University of Toronto, Canada
- Martin Orthopaedic Biomechanics Laboratory, St Michael’s Hospital, Canada
| | - Emil H Schemitsch
- Faculty of Medicine, University of Toronto, Canada
- Martin Orthopaedic Biomechanics Laboratory, St Michael’s Hospital, Canada
| | - Habiba Bougherara
- Department of Mechanical and Industrial Engineering, Ryerson University, Canada
| | - Rad Zdero
- Martin Orthopaedic Biomechanics Laboratory, St Michael’s Hospital, Canada
- Department of Mechanical and Industrial Engineering, Ryerson University, Canada
| |
Collapse
|