• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4632503)   Today's Articles (72)   Subscriber (49900)
For: Lorenz M, Semlitsch M, Panic B, Weber H, Willert HG. Fatigue Strength of Cobalt-Base Alloys with High Corrosion Resistance for Artificial Hip Joints. ACTA ACUST UNITED AC 2016. [DOI: 10.1243/emed_jour_1978_007_061_02] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Number Cited by Other Article(s)
1
Kajzer W, Szewczenko J, Kajzer A, Basiaga M, Jaworska J, Jelonek K, Nowińska K, Kaczmarek M, Orłowska A. Physical Properties of Electropolished CoCrMo Alloy Coated with Biodegradable Polymeric Coatings Releasing Heparin after Prolonged Exposure to Artificial Urine. MATERIALS (BASEL, SWITZERLAND) 2021;14:2551. [PMID: 34069039 PMCID: PMC8156080 DOI: 10.3390/ma14102551] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Revised: 05/02/2021] [Accepted: 05/12/2021] [Indexed: 11/17/2022]
2
Semlitsch M. Properties of Wrought CoNiCrMo Alloy Protasul-10, a Highly Corrosion and Fatigue Resistant Implant Material for Joint Endoprostheses. ACTA ACUST UNITED AC 2016. [DOI: 10.1243/emed_jour_1980_009_051_02] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
3
Martelli S, Taddei F, Cristofolini L, Schileo E, Rushton N, Viceconti M. A new hip epiphyseal prosthesis: Design revision driven by a validated numerical procedure. Med Eng Phys 2011;33:1203-11. [DOI: 10.1016/j.medengphy.2011.05.010] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2010] [Revised: 05/13/2011] [Accepted: 05/16/2011] [Indexed: 11/30/2022]
4
Keaveny TM, Bartel DL. Load transfer with the Austin Moore cementless hip prosthesis. J Orthop Res 1993;11:272-84. [PMID: 8483040 DOI: 10.1002/jor.1100110215] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
5
Heimke G. Biomaterials Highlights III. Bone Replacements: Implant Materials and the Modes of Implant Fixation. Angew Chem Int Ed Engl 1989. [DOI: 10.1002/ange.19891011045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
6
Heimke G. Biomaterials Highlights III: Bone Replacements: Implant Materials and the Modes of Implant Fixation. Angew Chem Int Ed Engl 1989. [DOI: 10.1002/anie.198914311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
7
Semlitsch M. Twenty years of Sulzer experience with artificial hip joint materials. Proc Inst Mech Eng H 1989;203:159-65. [PMID: 2679591 DOI: 10.1243/pime_proc_1989_203_028_01] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
8
Observations on the faceted fatigue fracture of cast Co−Cr−Mo alloy used for surgical implants. ACTA ACUST UNITED AC 1989. [DOI: 10.1007/bf02647497] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
9
Bolton JD, Hayden J, Humphreys M. A study of corrosion fatigue in cast cobalt-chrome-molybdenum alloys. ENGINEERING IN MEDICINE 1982;11:59-68. [PMID: 7201418 DOI: 10.1243/emed_jour_1982_011_018_02] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
10
Willert HG, Buchhorn U, Zichner L. Clinical experience with Mueller total hip endoprostheses of different design and material. ARCHIVES OF ORTHOPAEDIC AND TRAUMATIC SURGERY. ARCHIV FUR ORTHOPADISCHE UND UNFALL-CHIRURGIE 1980;97:197-205. [PMID: 7447669 DOI: 10.1007/bf00389727] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
11
Semilitsch M, Willert HG. Properties of implant alloys for artificial hip joints. Med Biol Eng Comput 1980;18:511-20. [PMID: 7421346 DOI: 10.1007/bf02443329] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
12
Hastings GW. Biomedical engineering and materials for orthopaedic implants. JOURNAL OF PHYSICS E: SCIENTIFIC INSTRUMENTS 1980;13:599-607. [PMID: 6993661 DOI: 10.1088/0022-3735/13/6/001] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA