1
|
Matsumoto N, Sugai S, Suzuki Y, Iguchi N, Nanasato M, Kiso K, Taniguchi Y, Yoneyama T, Okuda K, Nakajima K. Clinical Validation of Japanese Normal Myocardial Perfusion Imaging Databases Using Semi-conductor Gamma Camera (D-SPECT): Japanese Society of Nuclear Cardiology Working Group Reports. ANNALS OF NUCLEAR CARDIOLOGY 2022; 8:36-41. [PMID: 36540179 PMCID: PMC9749750 DOI: 10.17996/anc.22-00163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Revised: 06/07/2022] [Accepted: 06/08/2022] [Indexed: 06/17/2023]
Abstract
Objective: A working group (WG) of the Japanese Society of Nuclear Cardiology (JSNC) determined Japanese normal databases of myocardial perfusion single-photon emission computed tomography (SPECT) on semi-conductor gamma camera (D-SPECT), and the aim of this study was to validate its clinical utility. Materials and methods: The normal myocardial perfusion SPECT (MPS) databases of Japanese patients in the 201Tl stress/redistribution protocol (201Tl protocol), 99mTc stress/rest or rest/stress protocol (99mTc protocol), and rest 99mTc/stress 201Tl simultaneous acquisition dual-isotope protocol (SDI protocol) were created by JSNC WG. The WG collected clinical cases for the 201Tl protocol (male/female [m/f], 8/8), 99mTc protocol (m/f, 9/7), and SDI protocol (m/f, 10/10) from WG participating hospitals. Four WG members read those clinical cases on a 17-segment and 5-point scale (0-4). Using the most frequent values as the score for each segment, weighted κ values were calculated with the scores obtained from quantitative perfusion software (QPS). Results: Weighted κ values were as follows; 201Tl stress/female, 0.77; 201Tl rest/female, 0.74; 201Tl stress/male, 0.81; 201Tl rest/male, 0.68; 99mTc stress/female, 0.77; 99mTc rest/female, 0.62; 99mTc stress/male, 0.77; 99mTc rest/male, 0.75; SDI stress/female, 0.87; SDI rest/female, 0.82; SDI stress/male, 0.87; SDI rest/male, 0.85. Conclusions: The diagnostic accuracy of Japanese MPS normal databases on D-SPECT were comparable with nuclear cardiology expert reading and further clinical applications are expected.
Collapse
Affiliation(s)
- Naoya Matsumoto
- Department of Cardiology, Nihon University Hospital, Tokyo, Japan
| | - Shonosuke Sugai
- Department of Cardiology, Nihon University Hospital, Tokyo, Japan
| | - Yasuyuki Suzuki
- Department of Cardiology, Nihon University Hospital, Tokyo, Japan
| | - Nobuo Iguchi
- Department of Cardiology, Sakakibara Heart Institute, Fuchu, Japan
| | - Mamoru Nanasato
- Department of Cardiology, Sakakibara Heart Institute, Fuchu, Japan
| | - Keisuke Kiso
- Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Japan
| | - Yasuyo Taniguchi
- Department of General Medicine, Harima-Himeji General Medical Center, Himeji, Japan
| | - Tatsuya Yoneyama
- Department of Clinical Thyroid, Central Hospital of Matto Ishikawa, Hakusan, Japan
| | - Koichi Okuda
- Department of Physics, Kanazawa Medical University, Kanazawa, Japan
| | - Kenichi Nakajima
- Department of Functional Imaging and Artificial Intelligence, Kanazawa University, Kanazawa, Japan
| |
Collapse
|
2
|
Hachiya S, Kosuge H, Fujita Y, Hida S, Chikamori T. Performance of Hybrid Imaging in the Diagnosis of Coronary Artery Disease. Am J Cardiol 2022; 174:34-39. [PMID: 35379453 DOI: 10.1016/j.amjcard.2022.02.043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Revised: 02/18/2022] [Accepted: 02/22/2022] [Indexed: 11/19/2022]
Abstract
Single-photon emission computed tomography (SPECT) and computed tomography coronary angiography (CTCA) are usually performed independently in patients with suspected coronary artery disease. We assessed the hypothesis that hybrid SPECT/CTCA imaging results in higher diagnostic accuracy than either method alone, particularly in cases presenting with high levels of coronary calcification. A total of 243 major coronary vessels in 81 patients with known or suspected coronary artery disease were screened using SPECT with semiconductor detectors and CTCA with 256-detector row computed tomography. Patients who were diagnosed with myocardial ischemia underwent coronary angiography. Coronary angiography results were defined as positive for stenosis when the stenosis diameter was >70% or fractional flow reserve was <0.8. These data were then compared with a fused image of the SPECT and CTCA datasets generated using a dedicated workstation. To detect significant coronary artery stenosis, the respective sensitivity, specificity, and accuracy were 73%, 61%, and 67% with SPECT alone, 96%, 44%, and 67% with CTCA alone, and 95%, 75%, and 84% with hybrid imaging. Moreover, hybrid imaging allowed the accurate diagnosis of 47 vessels with severe calcification that CTCA alone could not evaluate correctly. Hybrid imaging shows greater diagnostic accuracy than single-modality evaluation through more comprehensive information on potential coronary stenosis and its hemodynamic significance.
Collapse
Affiliation(s)
- Shoko Hachiya
- Department of Cardiology, Tokyo Medical University, Tokyo, Japan
| | - Hisanori Kosuge
- Department of Cardiology, Tokyo Medical University, Tokyo, Japan.
| | - Yasuhiro Fujita
- Department of Cardiology, Tokyo Medical University, Tokyo, Japan
| | - Satoshi Hida
- Department of Cardiology, Tokyo Medical University, Tokyo, Japan
| | | |
Collapse
|
3
|
Sala M, Kincl V, Kamínek M, Vašina J, Máchal J, Panovský R, Feitová V, Opatřil L, Holeček T. Assessment of left ventricular volumes and ejection fraction using ultra-low-dose thallium-201 SPECT on a CZT camera: a comparison with magnetic resonance imaging. J Nucl Cardiol 2022; 29:181-187. [PMID: 32410056 DOI: 10.1007/s12350-020-02161-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2020] [Accepted: 04/14/2020] [Indexed: 10/24/2022]
Abstract
BACKGROUND Cadmium-Zinc-Telluride (CZT) technology allows use of low activities of radiopharmaceuticals. The aim was to verify the values of left ventricular volume parameters, obtained via ultra-low-dose thallium Single Photon Emission Computed Tomography (SPECT) using a CZT camera. METHODS AND RESULTS Forty-five patients referred for an assessment of myocardial perfusion or viability imaging were examined using CZT-SPECT and 1.5 T magnetic resonance (MRI) scanner. The ultra-low-dose protocol with 0.5 Mbq 201-Tl per kg of body weight was used. The values of end-systolic (ESV) and end-diastolic volumes (EDV), left ventricular ejection fraction (EF) and myocardial mass (MM) were assessed using both techniques. A very good correlation was found between the EF, ESV, and EDV values assessed with CZT-SPECT and cardiac magnetic resonance MRI; the Pearson coefficients were 0.86, 0.95, and 0.91, respectively. A moderate correlation was found for myocardial mass, r = 0.57. Compared to MRI, SPECT systematically overestimated ESV and MM, while it underestimates the EF, with P ≤ .001 in all cases. There was no difference in EDV estimation. CONCLUSIONS Left ventricular volumes and ejection fraction assessed via ultra-low-dose CZT-SPECT showed very good correlation with the values obtained by MRI. A moderate correlation was found for myocardial mass.
Collapse
Affiliation(s)
- Marek Sala
- Department of Internal Medicine/Cardiology, St. Anne´s University Hospital, Masaryk University, Pekařská 53, 656 91, Brno, Czech Republic
| | - Vladimír Kincl
- Department of Internal Medicine/Cardiology, St. Anne´s University Hospital, Masaryk University, Pekařská 53, 656 91, Brno, Czech Republic.
- International Clinical Research Center, St. Anne´s University Hospital, Brno, Czech Republic.
| | - Milan Kamínek
- International Clinical Research Center, St. Anne´s University Hospital, Brno, Czech Republic
- Department of Nuclear Medicine, University Hospital Olomouc, Palacký University, Olomouc, Czech Republic
| | - Jiří Vašina
- International Clinical Research Center, St. Anne´s University Hospital, Brno, Czech Republic
- Department of Nuclear Medicine, Masaryk Memorial Cancer Center, Brno, Czech Republic
| | - Jan Máchal
- International Clinical Research Center, St. Anne´s University Hospital, Brno, Czech Republic
- Department of Pathological Physiology, Masaryk University, Brno, Czech Republic
| | - Roman Panovský
- Department of Internal Medicine/Cardiology, St. Anne´s University Hospital, Masaryk University, Pekařská 53, 656 91, Brno, Czech Republic
- International Clinical Research Center, St. Anne´s University Hospital, Brno, Czech Republic
| | - Věra Feitová
- International Clinical Research Center, St. Anne´s University Hospital, Brno, Czech Republic
- Department of Medical Imaging, St. Anne´s University Hospital, Masaryk University, Brno, Czech Republic
| | - Lukáš Opatřil
- Department of Internal Medicine/Cardiology, St. Anne´s University Hospital, Masaryk University, Pekařská 53, 656 91, Brno, Czech Republic
- International Clinical Research Center, St. Anne´s University Hospital, Brno, Czech Republic
| | - Tomáš Holeček
- International Clinical Research Center, St. Anne´s University Hospital, Brno, Czech Republic
- Department of Medical Imaging, St. Anne´s University Hospital, Masaryk University, Brno, Czech Republic
| |
Collapse
|
4
|
Shiraishi S, Tsuda N, Sakamoto F, Ogasawara K, Tomiguchi S, Tsujita K, Yamashita Y. Clinical usefulness of quantification of myocardial blood flow and flow reserve using CZT-SPECT for detecting coronary artery disease in patients with normal stress perfusion imaging. J Cardiol 2020; 75:400-409. [DOI: 10.1016/j.jjcc.2019.09.006] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/28/2019] [Revised: 08/18/2019] [Accepted: 09/03/2019] [Indexed: 11/16/2022]
|
5
|
Barone-Rochette G, Zoreka F, Djaileb L, Piliero N, Calizzano A, Quesada JL, Broisat A, Riou L, Machecourt J, Fagret D, Vanzetto G, Ghezzi C. Diagnostic value of stress thallium-201/rest technetium-99m-sestamibi sequential dual isotope high-speed myocardial perfusion imaging for the detection of haemodynamically relevant coronary artery stenosis. J Nucl Cardiol 2019; 26:1269-1279. [PMID: 29380286 DOI: 10.1007/s12350-018-1189-8] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2017] [Revised: 01/04/2018] [Indexed: 12/13/2022]
Abstract
BACKGROUND The aim of this study was to determine the diagnostic accuracy of stress thallium-201/rest technetium-99m-sestamibi sequential dual-isotope high-speed myocardial perfusion imaging (DI-HS-MPI) against invasively determined fractional flow reserve (FFR). METHODS Fifty-four consecutive patients prospectively underwent DI-HS-MPI before invasive coronary angiography. Perfusion was scored visually by summed stress score on a patient and coronary territory basis. Significant coronary artery disease (CAD) was defined by the presence of ≥ 90% stenosis/occlusion or fractional flow reserve ≤ 0.80 for coronary stenosis ≥ 50%. RESULTS FFR was measured in 69 of 162 coronary vessels, with 1.28 ± 0.56 vessels assessed/patient. Sensitivity, specificity, and diagnostic accuracy of MPI for the detection of significant CAD were 92.8%, 69.2%, and 81.4%, on a patient basis, and 83.7%, 90.4%, and 88.8% by coronary territory. CONCLUSIONS DI-HS-MPI accurately detects functionally significant CAD as defined by using FFR.
Collapse
Affiliation(s)
- Gilles Barone-Rochette
- Department of Cardiology, University Hospital, Grenoble Alpes, France.
- INSERM U1039, Bioclinic Radiopharmaceutics Laboratory, Grenoble Alpes, France.
- French Alliance Clinical Trial, French Clinical Research Infrastructure Network, Paris, France.
| | - Feras Zoreka
- Department of Cardiology, University Hospital, Grenoble Alpes, France
| | - Loïc Djaileb
- Department of Nuclear medicine, University Hospital, Grenoble Alpes, France
| | - Nicolas Piliero
- Department of Cardiology, University Hospital, Grenoble Alpes, France
| | - Alex Calizzano
- Department of Nuclear medicine, University Hospital, Grenoble Alpes, France
| | - Jean Louis Quesada
- Center of Clinical Investigations, Grenoble Alpes University Hospital, Grenoble, France
| | - Alexis Broisat
- INSERM U1039, Bioclinic Radiopharmaceutics Laboratory, Grenoble Alpes, France
| | - Laurent Riou
- INSERM U1039, Bioclinic Radiopharmaceutics Laboratory, Grenoble Alpes, France
| | | | - Daniel Fagret
- INSERM U1039, Bioclinic Radiopharmaceutics Laboratory, Grenoble Alpes, France
- Department of Nuclear medicine, University Hospital, Grenoble Alpes, France
| | - Gerald Vanzetto
- Department of Cardiology, University Hospital, Grenoble Alpes, France
- INSERM U1039, Bioclinic Radiopharmaceutics Laboratory, Grenoble Alpes, France
- French Alliance Clinical Trial, French Clinical Research Infrastructure Network, Paris, France
| | - Catherine Ghezzi
- INSERM U1039, Bioclinic Radiopharmaceutics Laboratory, Grenoble Alpes, France
| |
Collapse
|
6
|
The prognostic value of ultra low-dose thallium myocardial perfusion protocol using CZT SPECT. Int J Cardiovasc Imaging 2019; 35:1163-1167. [PMID: 30680654 DOI: 10.1007/s10554-019-01535-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/26/2018] [Accepted: 01/14/2019] [Indexed: 01/07/2023]
Abstract
The purpose of this study was to assess the prognostic value of ultra-low dose thallium myocardial perfusion imaging. Three hundred and sixty-six patients (245 men) underwent ultra-low dose stress-redistribution imaging on CZT SPECT camera GE Discovery NM 530c. The stress test was performed by bicycle ergometry or regadenoson injection. The activity of 0.5 MBq (0.014 mCi) Tl-201 chloride per kilogram of body weight was administered. The stress images were acquired immediately and redistribution images were taken after 3 h. Patient follow-up was focused on combined end-point (death, myocardial infarction, unstable angina, revascularization and hospitalization for heart failure). Data analysis was performed from hospital database, with a mean period 23 months. Patients with revascularization within 1 month after SPECT was excluded as revascularization for diagnosis. Ischaemia on SPECT was found in 72 patients, 294 patients were without ischaemia. In patients with ischaemia there were 21 (29.2%) subjects with cardiac events, and 23 (7.9%) in patients without ischaemia (HR 4.15, 95% CI 2.30-7.51, p < 0.0001). Ultra-low dose thallium perfusion imaging using CZT camera provides very good prognostic results in assessment of myocardial ischaemia.
Collapse
|
7
|
Kawamura I, Kajiura R, Motoji Y, Okamoto S, Tanigaki T, Omori H, Hirata T, Kikuchi J, Ota H, Sobue Y, Miyake T, Tsunekawa T, Kato T, Kawase Y, Okubo M, Kamiya H, Tsuchiya K, Tomita S, Hirakawa A, Kondo T, Suzuki T, Matsuo H. Diagnostic Performance of the Simultaneous Acquisition Rest <sup>99 m</sup>Tc-Tetrofosmin/Stress <sup>201</sup>Tl Dual-Isotope Protocol With a Semiconductor Camera ― Comparison With the Rest-Stress <sup>99 m</sup>Tc-Tetrofosmin Protocol ―. Circ J 2018; 82:2837-2844. [DOI: 10.1253/circj.cj-18-0363] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | - Akihiro Hirakawa
- Department of Biostatistics and Bioinformatics, Graduate School of Medicine, The University of Tokyo
| | | | | | | |
Collapse
|
8
|
Hirose K, Chikamori T, Hida S, Tanaka N, Yamashita J, Igarashi Y, Saitoh T, Tanaka H, Yamashina A. Application of pressure-derived myocardial fractional flow reserve in chronic hemodialysis patients. J Cardiol 2018; 71:52-58. [DOI: 10.1016/j.jjcc.2017.05.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2017] [Revised: 05/19/2017] [Accepted: 05/26/2017] [Indexed: 01/25/2023]
|
9
|
Seike F, Uetani T, Nishimura K, Kawakami H, Higashi H, Fujii A, Aono J, Nagai T, Inoue K, Suzuki J, Inaba S, Okura T, Yasuda K, Higaki J, Ikeda S. Intravascular Ultrasound-Derived Virtual Fractional Flow Reserve for the Assessment of Myocardial Ischemia. Circ J 2018; 82:815-823. [DOI: 10.1253/circj.cj-17-1042] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Fumiyasu Seike
- Department of Cardiology, Pulmonology, Hypertension & Nephrology, Ehime University Graduate School of Medicine
| | - Teruyoshi Uetani
- Department of Cardiology, Pulmonology, Hypertension & Nephrology, Ehime University Graduate School of Medicine
| | - Kazuhisa Nishimura
- Department of Cardiology, Pulmonology, Hypertension & Nephrology, Ehime University Graduate School of Medicine
| | - Hiroshi Kawakami
- Department of Cardiology, Pulmonology, Hypertension & Nephrology, Ehime University Graduate School of Medicine
| | - Haruhiko Higashi
- Department of Cardiology, Pulmonology, Hypertension & Nephrology, Ehime University Graduate School of Medicine
| | - Akira Fujii
- Department of Cardiology, Pulmonology, Hypertension & Nephrology, Ehime University Graduate School of Medicine
| | - Jun Aono
- Department of Cardiology, Pulmonology, Hypertension & Nephrology, Ehime University Graduate School of Medicine
| | - Takayuki Nagai
- Department of Cardiology, Pulmonology, Hypertension & Nephrology, Ehime University Graduate School of Medicine
| | - Katsuji Inoue
- Department of Cardiology, Pulmonology, Hypertension & Nephrology, Ehime University Graduate School of Medicine
| | - Jun Suzuki
- Department of Cardiology, Pulmonology, Hypertension & Nephrology, Ehime University Graduate School of Medicine
| | | | - Takafumi Okura
- Department of Cardiology, Pulmonology, Hypertension & Nephrology, Ehime University Graduate School of Medicine
| | - Kazunori Yasuda
- Department of Mechanical Engineering, Ehime University Graduate School of Science and Engineering
| | - Jitsuo Higaki
- Department of Cardiology, Pulmonology, Hypertension & Nephrology, Ehime University Graduate School of Medicine
| | - Shuntaro Ikeda
- Department of Cardiology, Pulmonology, Hypertension & Nephrology, Ehime University Graduate School of Medicine
| |
Collapse
|
10
|
Daou D, Sabbah R, Coaguila C, Boulahdour H. Feasibility of data-driven cardiac respiratory motion correction of myocardial perfusion CZT SPECT: A pilot study. J Nucl Cardiol 2017; 24:1598-1607. [PMID: 27170338 DOI: 10.1007/s12350-016-0493-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2016] [Accepted: 03/29/2016] [Indexed: 10/21/2022]
Abstract
BACKGROUND We developed a data-driven respiratory motion (RM) correction method (REGAT program) for multiple-pinhole detector CZT SPECT. We verified its clinical feasibility with myocardial perfusion imaging (MPI) and studied its impact on image characteristics. METHODS This retrospective study included 18 patients having stress/rest 99mTc-Tetrofosmin MPI SPECT. List mode was acquired on CZT SPECT and processed with REGAT. REGAT generates reconstructed RM-gated volumes that are summed either without realignment (NR-SPECT) or after realignment (R-SPECT). For both stress and rest, we calculated the maximal RM in the 3 axis, and image characteristics of both R-SPECT and NR-SPECT: minimum left ventricular (LV) cavity counts (LV-Min), maximum LV myocardial counts (LV-Max), LV contrast, and FWHM of both anterior (FWHM-ant) and inferior (FWHM-inf) LV myocardial walls. RESULTS At both stress and rest, cranio-caudal motion was the dominant axial movement and REGAT had a positive impact on image characteristics as reflected by variations between R-SPECT and NR-SPECT in LV-Min, LV-Max, FWHM-ant, FWHM-inf, and contrast. These latter were well correlated to the amplitude of cranio-caudal motion at both stress and rest. CONCLUSIONS Data-driven RM correction of MPI acquired with CZT SPECT is clinically feasible and easily applicable. It presents interesting impact on image characteristics.
Collapse
Affiliation(s)
- Doumit Daou
- EA 7334 REMES, Université Paris-Diderot, Sorbonne Paris-Cité, Paris, France.
- Nuclear Medicine Department, Cochin University Hospital, AP-HP, 27 rue du Faubourg Saint-Jacques, 75679, Paris Cedex 14, France.
| | - Rémy Sabbah
- Nuclear Medicine Department, CHU Jean Minjoz, Besançon, France
| | - Carlos Coaguila
- Nuclear Medicine Department, Centre Hospitalier de Bigorre, Tarbes, France
| | | |
Collapse
|
11
|
Ito S, Endo A, Okada T, Nakamura T, Sugamori T, Takahashi N, Yoshitomi H, Tanabe K. Comparison of CTAC and prone imaging for the detection of coronary artery disease using CZT SPECT. Ann Nucl Med 2017; 31:629-635. [PMID: 28695497 PMCID: PMC5622918 DOI: 10.1007/s12149-017-1194-z] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2017] [Accepted: 07/05/2017] [Indexed: 11/25/2022]
Abstract
Background Cadmium-zinc-telluride (CZT) cameras have improved the evaluation of patients with chest pain. However, inferior/inferolateral attenuation artifacts similar to those seen with conventional Anger cameras persist. We added prone acquisitions and CT attenuation correction (CTAC) to the standard supine image acquisition and analyzed the resulting examinations. Methods and results Seventy-two patients referred for invasive coronary angiography (CAG), and who also underwent rest/stress myocardial perfusion imaging (MPI) on a CZT camera in the supine and prone positions plus CTAC imaging, to examine known or suspected CAD between April 2013 and March 2014 were included. A sixteen-slice CT scan acquired on a SPECT/CT scanner between rest and stress imaging provided data for iterative reconstruction. Sensitivity, specificity, accuracy, and positive and negative likelihood ratios (LRs) were calculated to compare MPI with CAG on a per-patient basis. Per-patient sensitivity, specificity, and accuracy of supine images to predict coronary abnormalities on CAG were 35% [95% confidence interval (CI) 19–52], 86% (95% CI 80–92), and 74% (95% CI 66–82); those of prone imaging were 65% (95% CI 45–81), 82% (95% CI 76–87), and 78% (95% CI 68–85); and those of CTAC were 59% (95% CI 41–71), 93% (95% CI 87–97), and 85% (95% CI 76–91), respectively. Conclusions Prone acquisition and CTAC images improve the ability to assess the inferior/inferolateral area.
Collapse
Affiliation(s)
- Shimpei Ito
- Division of Cardiology, Shimane University Faculty of Medicine, 89-1 Enya-cho, Izumo, 693-8501, Japan.
| | - Akihiro Endo
- Division of Cardiology, Shimane University Faculty of Medicine, 89-1 Enya-cho, Izumo, 693-8501, Japan
| | - Taiji Okada
- Division of Cardiology, Shimane University Faculty of Medicine, 89-1 Enya-cho, Izumo, 693-8501, Japan
| | - Taku Nakamura
- Division of Cardiology, Shimane University Faculty of Medicine, 89-1 Enya-cho, Izumo, 693-8501, Japan
| | - Takashi Sugamori
- Division of Cardiology, Shimane University Faculty of Medicine, 89-1 Enya-cho, Izumo, 693-8501, Japan
| | - Nobuyuki Takahashi
- Division of Cardiology, Shimane University Faculty of Medicine, 89-1 Enya-cho, Izumo, 693-8501, Japan
| | - Hiroyuki Yoshitomi
- Clinical Laboratory Department, Shimane University Hospital, Izumo, Japan
| | - Kazuaki Tanabe
- Division of Cardiology, Shimane University Faculty of Medicine, 89-1 Enya-cho, Izumo, 693-8501, Japan
| |
Collapse
|
12
|
Ishihara M, Onoguchi M, Taniguchi Y, Shibutani T. Comparison of conventional and cadmium-zinc-telluride single-photon emission computed tomography for analysis of thallium-201 myocardial perfusion imaging: an exploratory study in normal databases for different ethnicities. Int J Cardiovasc Imaging 2017; 33:2057-2066. [PMID: 28664481 DOI: 10.1007/s10554-017-1205-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2017] [Accepted: 06/22/2017] [Indexed: 02/02/2023]
Abstract
The aim of this study was to clarify the differences in thallium-201-chloride (thallium-201) myocardial perfusion imaging (MPI) scans evaluated by conventional anger-type single-photon emission computed tomography (conventional SPECT) versus cadmium-zinc-telluride SPECT (CZT SPECT) imaging in normal databases for different ethnic groups. MPI scans from 81 consecutive Japanese patients were examined using conventional SPECT and CZT SPECT and analyzed with the pre-installed quantitative perfusion SPECT (QPS) software. We compared the summed stress score (SSS), summed rest score (SRS), and summed difference score (SDS) for the two SPECT devices. For a normal MPI reference, we usually use Japanese databases for MPI created by the Japanese Society of Nuclear Medicine, which can be used with conventional SPECT but not with CZT SPECT. In this study, we used new Japanese normal databases constructed in our institution to compare conventional and CZT SPECT. Compared with conventional SPECT, CZT SPECT showed lower SSS (p < 0.001), SRS (p = 0.001), and SDS (p = 0.189) using the pre-installed SPECT database. In contrast, CZT SPECT showed no significant difference from conventional SPECT in QPS analysis using the normal databases from our institution. Myocardial perfusion analyses by CZT SPECT should be evaluated using normal databases based on the ethnic group being evaluated.
Collapse
Affiliation(s)
- Masaru Ishihara
- Department of Radiology, Hyogo Cancer Center, 13-70 Kitaoji, Akashi, Hyogo, 673-8558, Japan.,Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, 920-0942, Japan
| | - Masahisa Onoguchi
- Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, 920-0942, Japan.
| | - Yasuyo Taniguchi
- Department of Cardiology, Hyogo Brain and Heart Center at Himeji, 520 Saisho-ko, Himeji, Hyogo, 670-0981, Japan
| | - Takayuki Shibutani
- Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, 920-0942, Japan
| |
Collapse
|
13
|
Gregoire B, Pina-Jomir G, Bontemps L, Janier M, Scheiber C. The value of local normal limits in quantitative Thallium-201 CZT MPI SPECT. J Nucl Cardiol 2017; 24:672-682. [PMID: 26936035 DOI: 10.1007/s12350-016-0430-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2015] [Accepted: 01/15/2016] [Indexed: 11/21/2022]
Abstract
BACKGROUND Considering the distinctive characteristics of CZT detectors, automatic quantification of ischemia using normal limits included with software package may deliver suboptimal results for CAD detection. The present study aims to evaluate the benefits of creating normal limits specific to a local population and laboratory protocol. METHODS AND RESULTS Two groups were selected from patients who had undergone a CZT MPI. Normal limits were generated with the QPS application based on the population with low likelihood of CAD. Using the vendor-supplied and the population-specific normal limits i-TPD and vessel-specific SDS results obtained for patients who had subsequently undergone coronary angiography were compared with coronary angiography data. A weak correlation was observed for low i-TPD (stress TPD minus rest TPD) and SDS values. Both databases gave similar values for the area under the ROC curve concerning i-TPD (0.75 to 0.74) and SDS results (0.72 to 0.75 for the LAD, 0.62 to 0.64 for the LCx, and 0.63 to 0.67 for the RCA). Sensitivity (60%), specificity (78%), and predictive positive (84%) and negative (52%) values were also similar with a diagnostic and prognostic threshold value. CONCLUSION The use of a population-specific created database did not influence the diagnostic value of thallium-201 MPI QPS results using a CZT camera.
Collapse
Affiliation(s)
- Bastien Gregoire
- Centre de Medicine Nucléaire, Hôpital Louis Pradel, 28, Avenue Doyen Lépine, 69500, Bron, France.
- Université Claude Bernard LYON 1, Faculté de Médecine de Lyon Est., 8 avenue Rockefeller, 69008, Lyon, France.
| | - Géraldine Pina-Jomir
- Centre de Medicine Nucléaire, Hôpital Louis Pradel, 28, Avenue Doyen Lépine, 69500, Bron, France
- Université Claude Bernard LYON 1, Faculté de Médecine de Lyon Est., 8 avenue Rockefeller, 69008, Lyon, France
| | - Laurence Bontemps
- Centre de Medicine Nucléaire, Hôpital Louis Pradel, 28, Avenue Doyen Lépine, 69500, Bron, France
- Université Claude Bernard LYON 1, Faculté de Médecine de Lyon Est., 8 avenue Rockefeller, 69008, Lyon, France
| | - Marc Janier
- Centre de Medicine Nucléaire, Hôpital Louis Pradel, 28, Avenue Doyen Lépine, 69500, Bron, France
- Université Claude Bernard LYON 1, Faculté de Médecine de Lyon Est., 8 avenue Rockefeller, 69008, Lyon, France
| | - Christian Scheiber
- Centre de Medicine Nucléaire, Hôpital Louis Pradel, 28, Avenue Doyen Lépine, 69500, Bron, France
- Université Claude Bernard LYON 1, Faculté de Médecine de Lyon Est., 8 avenue Rockefeller, 69008, Lyon, France
| |
Collapse
|
14
|
Chikamori T, Goto K, Hida S, Miyagawa M, Ishimura H, Uchida K, Fukuyama T, Mochizuki T, Yamashina A. Diagnostic performance of a semiconductor gamma-camera system as studied by multicenter registry. J Cardiol 2017; 69:449-455. [DOI: 10.1016/j.jjcc.2016.02.020] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2015] [Revised: 02/02/2016] [Accepted: 02/23/2016] [Indexed: 11/28/2022]
|
15
|
Otake H, Taylor CA, Matsuo H, Tanaka N, Akasaka T. Noninvasive Fractional Flow Reserve Derived From Coronary Computed Tomography Angiography ― Is This Just Another New Diagnostic Test or the Long-Awaited Game Changer? ―. Circ J 2017; 81:1085-1093. [DOI: 10.1253/circj.cj-16-0503] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Hiromasa Otake
- Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine
| | | | | | - Nobuhiro Tanaka
- Department of Cardiology, Tokyo Medical University Hachioji Medical Center
| | | |
Collapse
|
16
|
Feasibility of ultra low-dose thallium stress-redistribution protocol including prone imaging in obese patients using CZT camera. Int J Cardiovasc Imaging 2016; 32:1463-1469. [PMID: 27250348 DOI: 10.1007/s10554-016-0919-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2016] [Accepted: 05/27/2016] [Indexed: 10/21/2022]
Abstract
High efficiency cadmium-zinc-telluride (CZT) cameras provide an opportunity to lower the injected activities of radiopharmaceuticals for single photon emission tomography (SPECT) myocardial perfusion imaging (MPI). The limits for reducing activities of thallium have not been determined, particularly in obese patients. After an injection of 0.7 megabecquerel (MBq) of thallium/kg, we collected an average 1.5 million counts for the 10-min acquisition in a pilot cohort of ten patients. After extrapolation, we reduced the administered activity to 0.5 MBq/kg to obtain the expected 1 million counts. We studied the image quality in 124 patients (86 men, 43 obese with body mass index over 30 kg/m2) referred for MPI. The quality of images was assessed by a number of recorded counts and visually by a four-grade scale (one-poor quality, four-excellent quality). In non-obese and obese patients, the average number of recorded counts was 1.1 vs. 1.07 million counts for the 10-min stress acquisition, 1.04 vs. 1.06 million counts for the 13-min rest acquisition, and the average quality score was 3.97 vs. 3.90, respectively (p = NS).The mean administered activity was 39.2 ± 7 MBq for non-obese and 48.7 ± 6 for obese patients (p < 0.0001), and the calculated effective dose was 4.0 ± 0.7 and 4.9 ± 0.6 mSv respectively (p < 0.0001). The ultra-low-dose thallium stress-redistribution protocol, including post-stress prone imaging, provides good quality of images with a low radiation burden, even in obese patients.
Collapse
|
17
|
Goto K, Takebayashi H, Yamane H, Hagikura A, Kobayashi K, Morimoto Y, Kikuta Y, Sato K, Taniguchi M, Hiramatsu S, Haruta S. The diagnosis of intermediate coronary artery stenosis by myocardial perfusion imaging using an ultrafast cardiac gamma camera: Comparison with fractional flow reserve. Int J Cardiol 2016; 210:66-7. [PMID: 26930640 DOI: 10.1016/j.ijcard.2016.02.114] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2016] [Accepted: 02/16/2016] [Indexed: 11/24/2022]
Affiliation(s)
- Kenji Goto
- Fukuyama Cardiovascular Hospital, Fukuyama, Japan.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Normal values and standardization of parameters in nuclear cardiology: Japanese Society of Nuclear Medicine working group database. Ann Nucl Med 2016; 30:188-99. [PMID: 26897008 PMCID: PMC4819542 DOI: 10.1007/s12149-016-1065-z] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2015] [Accepted: 01/31/2016] [Indexed: 11/16/2022]
Abstract
As a 2-year project of the Japanese Society of Nuclear Medicine working group activity, normal myocardial imaging databases were accumulated and summarized. Stress-rest with gated and non-gated image sets were accumulated for myocardial perfusion imaging and could be used for perfusion defect scoring and normal left ventricular (LV) function analysis. For single-photon emission computed tomography (SPECT) with multi-focal collimator design, databases of supine and prone positions and computed tomography (CT)-based attenuation correction were created. The CT-based correction provided similar perfusion patterns between genders. In phase analysis of gated myocardial perfusion SPECT, a new approach for analyzing dyssynchrony, normal ranges of parameters for phase bandwidth, standard deviation and entropy were determined in four software programs. Although the results were not interchangeable, dependency on gender, ejection fraction and volumes were common characteristics of these parameters. Standardization of 123I-MIBG sympathetic imaging was performed regarding heart-to-mediastinum ratio (HMR) using a calibration phantom method. The HMRs from any collimator types could be converted to the value with medium-energy comparable collimators. Appropriate quantification based on common normal databases and standard technology could play a pivotal role for clinical practice and researches.
Collapse
|
19
|
Makita A, Matsumoto N, Suzuki Y, Hori Y, Kuronuma K, Yoda S, Kasama S, Iguchi N, Suzuki Y, Hirayama A. Clinical Feasibility of Simultaneous Acquisition Rest (99m)Tc/Stress (201)Tl Dual-Isotope Myocardial Perfusion Single-Photon Emission Computed Tomography With Semiconductor Camera. Circ J 2016; 80:689-95. [PMID: 26781361 DOI: 10.1253/circj.cj-15-1077] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND The aim of this study was to evaluate the clinical feasibility of simultaneous acquisition of rest (99m)Tc-tetrofosmin/stress (201)Tl dual-isotope single-photon emission computed tomography with a semiconductor gamma camera. METHODS AND RESULTS Ninety-four patients with known or suspected coronary artery disease (CAD) were enrolled in the study. First, patients were injected with (99m)Tc-tetrofosmin (296 MBq) for rest imaging, followed by (201)Tl (74 MBq) injection during 6 min of vasodilator stress test. Immediately after the stress test, the patients underwent the first electrocardiogram (ECG)-gated simultaneous acquisition including rest and stress perfusion scans. Patients were brought back for the second simultaneous acquisition for the comparison of ECG-gated wall motion between stress and rest scan 30 min later. Coronary angiography was performed in all the patients within 3 months of this protocol. Sensitivity, specificity and accuracy on a per patient basis to detect significant coronary artery stenosis (≥75%) were 88.6%, 79.2% and 86.2%, respectively. Per coronary vessel, sensitivity, specificity and accuracy were as follows: 84.9%, 80.5% and 83% in the left anterior descending coronary artery; 75%, 93.1% and 86.2% in the left circumflex coronary artery; and 74.2%, 85.7% and 81.9% in the right coronary artery. CONCLUSIONS Simultaneous acquisition of rest (99m)Tc-tetrofosmin/stress (201)Tl dual-isotope protocol had high diagnostic accuracy for significant CAD. (Circ J 2016; 80: 689-695).
Collapse
Affiliation(s)
- Ayano Makita
- Department of Cardiology, Nihon University Hospital
| | | | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Chikamori T, Hida S, Tanaka N, Igarashi Y, Yamashita J, Shiba C, Murata N, Hoshino K, Hokama Y, Yamashina A. Diagnostic Performance of a Cadmium-Zinc-Telluride Single-Photon Emission Computed Tomography System With Low-Dose Technetium-99m as Assessed by Fractional Flow Reserve. Circ J 2016; 80:1217-24. [DOI: 10.1253/circj.cj-16-0087] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
| | - Satoshi Hida
- Department of Cardiology, Tokyo Medical University
| | - Nobuhiro Tanaka
- Department of Cardiology, Tokyo Medical University Hachioji Medical Center
| | | | | | - Chie Shiba
- Department of Cardiology, Tokyo Medical University
| | | | - Kou Hoshino
- Department of Cardiology, Tokyo Medical University
| | - Yohei Hokama
- Department of Cardiology, Tokyo Medical University Hachioji Medical Center
| | | |
Collapse
|
21
|
Sakoda K, Tanaka N, Hokama Y, Hoshino K, Murata N, Yamashita J, Yamashina A. Association of moderate chronic kidney disease with insufficient improvement of fractional flow reserve after stent implantation. Catheter Cardiovasc Interv 2015; 88:E38-44. [DOI: 10.1002/ccd.26258] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2015] [Revised: 08/20/2015] [Accepted: 09/16/2015] [Indexed: 11/11/2022]
Affiliation(s)
- Kunihiro Sakoda
- Division of Cardiology, Department of Internal Medicine; Tokyo Medical University; Tokyo Japan
| | - Nobuhiro Tanaka
- Division of Cardiology, Department of Internal Medicine; Tokyo Medical University; Tokyo Japan
| | - Yohei Hokama
- Division of Cardiology, Department of Internal Medicine; Tokyo Medical University; Tokyo Japan
| | - Kou Hoshino
- Division of Cardiology, Department of Internal Medicine; Tokyo Medical University; Tokyo Japan
| | - Naotaka Murata
- Division of Cardiology, Department of Internal Medicine; Tokyo Medical University; Tokyo Japan
| | - Jun Yamashita
- Division of Cardiology, Department of Internal Medicine; Tokyo Medical University; Tokyo Japan
| | - Akira Yamashina
- Division of Cardiology, Department of Internal Medicine; Tokyo Medical University; Tokyo Japan
| |
Collapse
|
22
|
Shiraishi S, Sakamoto F, Tsuda N, Yoshida M, Tomiguchi S, Utsunomiya D, Ogawa H, Yamashita Y. Prediction of left main or 3-vessel disease using myocardial perfusion reserve on dynamic thallium-201 single-photon emission computed tomography with a semiconductor gamma camera. Circ J 2015; 79:623-31. [PMID: 25746547 DOI: 10.1253/circj.cj-14-0932] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
BACKGROUND Myocardial perfusion imaging (MPI) may fail to detect balanced ischemia. We evaluated myocardial perfusion reserve (MPR) using Tl dynamic single-photon emission computed tomography (SPECT) and a novel cadmium zinc telluride (CZT) camera for predicting 3-vessel or left main coronary artery disease (CAD). METHODS AND RESULTS: A total of 55 consecutive patients with suspected CAD underwent SPECT-MPI and coronary angiography. The MPR index was calculated using the standard 2-compartment kinetic model. We analyzed the utility of MPR index, other SPECT findings, and various clinical variables. On multivariate analysis, MPR index and history of previous myocardial infarction (MI) predicted left main and 3-vessel disease. The area under the receiver operating characteristic curve was 0.81 for MPR index, 0.699 for history of previous MI, and 0.86 for MPR index plus history of previous MI. MPR index ≤1.5 yielded the highest diagnostic accuracy. Sensitivity, specificity, and accuracy were 86%, 78%, and 80%, respectively, for MPR index, 64%, 76%, 73% for previous MI, and 57%, 93%, and 84% for MPR index plus history of previous MI. CONCLUSIONS Quantification of MPR using dynamic SPECT and a novel CZT camera may identify balanced ischemia in patients with left main or 3-vessel disease.
Collapse
Affiliation(s)
- Shinya Shiraishi
- Department of Diagnostic Radiology, Graduate School of Life Sciences, Kumamoto University
| | | | | | | | | | | | | | | |
Collapse
|
23
|
Kasai T. Cardiac Single-Photon Emission Computed Tomography Using Ultrafast Cadmium Zinc Telluride Gamma Camera With Thallium-201 Yields High-Diagnostic Performance Despite Lower Radiation Dose and Shorter Acquisition Time. Circ J 2014; 78:2635-6. [DOI: 10.1253/circj.cj-14-1032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Tokuo Kasai
- Department of Cardiology, Tokyo Medical University Hachioji Medical Center
| |
Collapse
|