1
|
Clases D, Gonzalez de Vega R. Facets of ICP-MS and their potential in the medical sciences-Part 1: fundamentals, stand-alone and hyphenated techniques. Anal Bioanal Chem 2022; 414:7337-7361. [PMID: 36028724 PMCID: PMC9482897 DOI: 10.1007/s00216-022-04259-1] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2022] [Revised: 07/26/2022] [Accepted: 07/29/2022] [Indexed: 12/02/2022]
Abstract
Since its inception in the early 80s, inductively coupled plasma–mass spectrometry has developed to the method of choice for the analysis of elements in complex biological systems. High sensitivity paired with isotopic selectivity and a vast dynamic range endorsed ICP-MS for the inquiry of metals in the context of biomedical questions. In a stand-alone configuration, it has optimal qualities for the biomonitoring of major, trace and toxicologically relevant elements and may further be employed for the characterisation of disrupted metabolic pathways in the context of diverse pathologies. The on-line coupling to laser ablation (LA) and chromatography expanded the scope and application range of ICP-MS and set benchmarks for accurate and quantitative speciation analysis and element bioimaging. Furthermore, isotopic analysis provided new avenues to reveal an altered metabolism, for the application of tracers and for calibration approaches. In the last two decades, the scope of ICP-MS was further expanded and inspired by the introduction of new instrumentation and methodologies including novel and improved hardware as well as immunochemical methods. These additions caused a paradigm shift for the biomedical application of ICP-MS and its impact in the medical sciences and enabled the analysis of individual cells, their microenvironment, nanomaterials considered for medical applications, analysis of biomolecules and the design of novel bioassays. These new facets are gradually recognised in the medical communities and several clinical trials are underway. Altogether, ICP-MS emerged as an extremely versatile technique with a vast potential to provide novel insights and complementary perspectives and to push the limits in the medical disciplines. This review will introduce the different facets of ICP-MS and will be divided into two parts. The first part will cover instrumental basics, technological advances, and fundamental considerations as well as traditional and current applications of ICP-MS and its hyphenated techniques in the context of biomonitoring, bioimaging and elemental speciation. The second part will build on this fundament and describe more recent directions with an emphasis on nanomedicine, immunochemistry, mass cytometry and novel bioassays.
Collapse
Affiliation(s)
- David Clases
- Nano Mirco LAB, Institute of Chemistry, University of Graz, Graz, Austria.
| | | |
Collapse
|
2
|
Dinges SS, Hohm A, Vandergrift LA, Nowak J, Habbel P, Kaltashov IA, Cheng LL. Cancer metabolomic markers in urine: evidence, techniques and recommendations. Nat Rev Urol 2020; 16:339-362. [PMID: 31092915 DOI: 10.1038/s41585-019-0185-3] [Citation(s) in RCA: 86] [Impact Index Per Article: 21.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Urinary tests have been used as noninvasive, cost-effective tools for screening, diagnosis and monitoring of diseases since ancient times. As we progress through the 21st century, modern analytical platforms have enabled effective measurement of metabolites, with promising results for both a deeper understanding of cancer pathophysiology and, ultimately, clinical translation. The first study to measure metabolomic urinary cancer biomarkers using NMR and mass spectrometry (MS) was published in 2006 and, since then, these techniques have been used to detect cancers of the urological system (kidney, prostate and bladder) and nonurological tumours including those of the breast, ovary, lung, liver, gastrointestinal tract, pancreas, bone and blood. This growing field warrants an assessment of the current status of research developments and recommendations to help systematize future research.
Collapse
Affiliation(s)
- Sarah S Dinges
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.,Department of Pathology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.,Department of Haematology and Oncology, CCM, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Annika Hohm
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.,Department of Pathology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.,Department of Diagnostic and Interventional Neuroradiology, University Hospital of Würzburg, Würzburg, Germany
| | - Lindsey A Vandergrift
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.,Department of Pathology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Johannes Nowak
- Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Würzburg, Germany
| | - Piet Habbel
- Department of Haematology and Oncology, CCM, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Igor A Kaltashov
- Department of Chemistry, University of Massachusetts-Amherst, Amherst, MA, USA.
| | - Leo L Cheng
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA. .,Department of Pathology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
3
|
González-Domínguez R. Size Fractionation of Metal Species from Serum Samples for Studying Element Biodistribution in Alzheimer’s Disease. METALS IN THE BRAIN 2017. [DOI: 10.1007/978-1-4939-6918-0_8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
4
|
Maes E, Tirez K, Baggerman G, Valkenborg D, Schoofs L, Encinar JR, Mertens I. The use of elemental mass spectrometry in phosphoproteomic applications. MASS SPECTROMETRY REVIEWS 2016; 35:350-360. [PMID: 25139451 DOI: 10.1002/mas.21440] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2013] [Revised: 05/14/2014] [Accepted: 05/14/2014] [Indexed: 06/03/2023]
Abstract
Reversible phosphorylation is one of the most important post-translational modifications in mammalian cells. Because this molecular switch is an important mechanism that diversifies and regulates proteins in cellular processes, knowledge about the extent and quantity of phosphorylation is very important to understand the complex cellular interplay. Although phosphoproteomics strategies are applied worldwide, they mainly include only molecular mass spectrometry (like MALDI or ESI)-based experiments. Although identification and relative quantification of phosphopeptides is straightforward with these techniques, absolute quantification is more complex and usually requires for specific isotopically phosphopeptide standards. However, the use of elemental mass spectrometry, and in particular inductively coupled plasma mass spectrometry (ICP-MS), in phosphoproteomics-based experiments, allow one to absolutely quantify phosphopeptides. Here, these phosphoproteomic applications with ICP-MS as elemental detector are reviewed. Pioneering work and recent developments in the field are both described. Additionally, the advantage of the parallel use of molecular and elemental mass spectrometry is stressed.
Collapse
Affiliation(s)
- Evelyne Maes
- Flemish Institute for Technological Research (VITO), Mol, Belgium
- KU Leuven, Research Group of Functional Genomics and Proteomics, Leuven, Belgium
| | - Kristof Tirez
- Flemish Institute for Technological Research (VITO), Mol, Belgium
| | - Geert Baggerman
- Flemish Institute for Technological Research (VITO), Mol, Belgium
- CFP-CeProMa, University of Antwerp, Antwerp, Belgium
| | - Dirk Valkenborg
- Flemish Institute for Technological Research (VITO), Mol, Belgium
- CFP-CeProMa, University of Antwerp, Antwerp, Belgium
- Interuniversity Institute for Biostatistics and Statistical Bioinformatics, Hasselt University, Diepenbeek, Belgium
| | - Liliane Schoofs
- KU Leuven, Research Group of Functional Genomics and Proteomics, Leuven, Belgium
| | - Jorge Ruiz Encinar
- Department of Physical and Analytical Chemistry, University of Oviedo, Oviedo, Spain
| | - Inge Mertens
- Flemish Institute for Technological Research (VITO), Mol, Belgium
- CFP-CeProMa, University of Antwerp, Antwerp, Belgium
| |
Collapse
|
5
|
Maes E, Brusten W, Beutels F, Baggerman G, Mertens I, Valkenborg D, Landuyt B, Schoofs L, Tirez K. The benefits and limitations of reaction cell and sector field inductively coupled plasma mass spectrometry in the detection and quantification of phosphopeptides. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2015; 29:35-44. [PMID: 25462361 DOI: 10.1002/rcm.7079] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2014] [Revised: 10/16/2014] [Accepted: 10/16/2014] [Indexed: 06/04/2023]
Abstract
RATIONALE The phosphorylation of proteins is one of the most important post-translational modifications in nature. Knowledge of the quantity or degree of protein phosphorylation in biological samples is extremely important. A combination of liquid chromatography (LC) and inductively coupled plasma mass spectrometry (ICP-MS) allows the absolute and relative quantification of the phosphorus signal. METHODS A comparison between dynamic reaction cell quadrupole ICP-MS (DRC-Q-ICP-MS) and high-resolution sector field ICP-MS (SF-ICP-MS) in detecting signals of phosphorus-containing species using identical capillary LC (reversed-phase technology) and nebulizer settings was performed. RESULTS A method to diminish the reversed-phase gradient-related signal instability in phosphorus detection with LC/ICP-MS applications was developed. Bis(4-nitrophenyl)phosphate (BNPP) was used as a standard to compare signal-to-noise ratios and limits of detection (LODs) between the two instrumental setups. The LOD reaches a value of 0.8 µg L(-1) when applying the DRC technology in Q-ICP-MS and an LOD of 0.09 µg L(-1) was found with the SF-ICP-MS setup. This BNPP standard was further used to compare the absolute quantification possibilities of phosphopeptides in these two setups. CONCLUSIONS This one-to-one comparison of two interference-reducing ICP-MS instruments demonstrates that absolute quantification of individual LC-separated phosphopeptides is possible. However, based on the LOD values, SF-ICP-MS has a higher sensitivity in detecting phosphorus signals and thus is preferred in phosphopeptide analysis.
Collapse
Affiliation(s)
- Evelyne Maes
- Flemish Institute for Technological Research (VITO), Mol, Belgium; CFP-CeProMa, University of Antwerp, Antwerp, Belgium; KU Leuven, Research Group of Functional Genomics and Proteomics, Leuven, Belgium
| | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Bi X, Jin Y, Gao X, Liu F, Gao D, Jiang Y, Liu H. Investigation of Pokemon-regulated proteins in hepatocellular carcinoma using mass spectrometry-based multiplex quantitative proteomics. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2013; 19:111-121. [PMID: 24261083 DOI: 10.1255/ejms.1221] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Pokemon is a transcription regulator involved in embryonic development, cellular differentiation and oncogenesis. It is aberrantly overexpressed in multiple human cancers including Hepatocellular carcinoma (HCC) and is considered as a promising biomarker for HCC. In this work, the isobaric tags for relative and absolute quantitation (iTRAQ)-based quantitative proteomics strategy was used to investigate the proteomic profile associated with Pokemon in human HCC cell line QGY7703 and human hepatocyte line HL7702. Samples were labeled with four-plex iTRAQ reagents followed by two-dimensional liquid chromatography coupled with tandem mass spectrometry analysis. A total of 24 differentially expressed proteins were selected as significant. Nine proteins were potentially up-regulated by Pokemon while 15 proteins were potentially down-regulated and many proteins were previously identified as potential biomarkers for HCC. Gene ontology (GO) term enrichment revealed that the listed proteins were mainly involved in DNA metabolism and biosynthesis process. The changes of glucose-6-phosphate 1-dehydrogenase (G6PD, up-regulated) and ribonucleoside-diphosphate reductase large sub-unit (RIM1, down-regulated) were validated by Western blotting analysis and denoted as Pokemon's function of oncogenesis. We also found that Pokemon potentially repressed the expression of highly clustered proteins (MCM3, MCM5, MCM6, MCM7) which played key roles in promoting DNA replication. Altogether, our results may help better understand the role of Pokemon in HCC and promote the clinical applications.
Collapse
Affiliation(s)
- Xin Bi
- Department of Chemistry, Tsinghua University, Beijing 100084, China
| | | | | | | | | | | | | |
Collapse
|
7
|
Kretschy D, Koellensperger G, Hann S. Elemental labelling combined with liquid chromatography inductively coupled plasma mass spectrometry for quantification of biomolecules: a review. Anal Chim Acta 2012; 750:98-110. [PMID: 23062431 PMCID: PMC3475989 DOI: 10.1016/j.aca.2012.06.040] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2012] [Revised: 06/23/2012] [Accepted: 06/25/2012] [Indexed: 01/02/2023]
Abstract
This article reviews novel quantification concepts where elemental labelling is combined with flow injection inductively coupled plasma mass spectrometry (FI-ICP-MS) or liquid chromatography inductively coupled plasma mass spectrometry (LC-ICP-MS), and employed for quantification of biomolecules such as proteins, peptides and related molecules in challenging sample matrices. In the first sections an overview on general aspects of biomolecule quantification, as well as of labelling will be presented emphasizing the potential, which lies in such methodological approaches. In this context, ICP-MS as detector provides high sensitivity, selectivity and robustness in biological samples and offers the capability for multiplexing and isotope dilution mass spectrometry (IDMS). Fundamental methodology of elemental labelling will be highlighted and analytical, as well as biomedical applications will be presented. A special focus will lie on established applications underlining benefits and bottlenecks of such approaches for the implementation in real life analysis. Key research made in this field will be summarized and a perspective for future developments including sophisticated and innovative applications will given.
Collapse
Affiliation(s)
| | | | - Stephan Hann
- University of Natural Resources and Life Sciences, BOKU Vienna, Department of Chemistry, Division of Analytical Chemistry, Muthgasse 18, A-1190 Vienna, Austria
| |
Collapse
|
8
|
Biological responses related to agonistic, antagonistic and synergistic interactions of chemical species. Anal Bioanal Chem 2012; 403:2237-53. [DOI: 10.1007/s00216-012-5776-2] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2011] [Revised: 01/17/2012] [Accepted: 01/20/2012] [Indexed: 01/26/2023]
|
9
|
Protein fractionation and detection for metalloproteomics: challenges and approaches. Anal Bioanal Chem 2012; 402:3311-22. [DOI: 10.1007/s00216-012-5743-y] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2011] [Revised: 01/09/2012] [Accepted: 01/12/2012] [Indexed: 12/17/2022]
|
10
|
Kretschy D, Gröger M, Zinkl D, Petzelbauer P, Koellensperger G, Hann S. High-throughput flow injection analysis of labeled peptides in cellular samples - ICP-MS analysis versus fluorescence based detection. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY 2011; 307:105-111. [PMID: 22723737 PMCID: PMC3378036 DOI: 10.1016/j.ijms.2011.02.008] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
A high throughput method based on flow injection analysis was developed and validated for the quantification of the peptide Bβ(15-42) in cellular samples comparing different labeling strategies and detection methods. The used labels were 1,4,7,10-tetraazacyclododecane-N, N', N'', N'''-tetraaceticacid (In-DOTA) and 2-(4-isothiocyanatobenzyl) - 1,4,7,10-tetraazacyclododecane-N, N', N'', N'''-tetraacetic acid (In-DOTA-Bn) for elemental labeling. 6-Hydroxy-9-(2-carboxyphenyl)- (3H)-xanthen-3-on (fluorescein) was employed as fluorescence label. The explored peptide (mass = 3 kD) is a novel candidate drug, which shows an anti-inflammatory effect after an event of myocardial infarction. The analysed samples were fractioned cell compartments of human umbilical cord vein endothelial cells (HUVEC) maintained via lysis with Triton X buffer. In order to enhance sensitivity and selectivity of peptide quantification via flow injection the peptide was labeled prior to incubation using elemental and fluorescence labels. Quantification of the elemental and fluorescence labeled peptide was performed via flow injection analysis combined with inductive coupled plasma sector field mass spectrometry (FIA-ICP-SFMS) or fluorescence detection (FIA-FLD), respectively. The employed quantification strategies were external calibration in the case of fluorescence detection and external calibration with and without internal standardization and on-line IDMS in the case of ICP-MS detectionThe limit of detection (LOD) for FIA-ICP-MS was 9 pM In-DOTA-Bβ(15-42) (0.05 fmol absolute) whereas FIA-FLD showed a LOD of 100 pM (3 fmol absolute) for the fluorescein labeled peptide. Short term precision of FIA-ICP-MS was superior for all ICP-MS based quantification strategies compared to FIA-FLD (FIA-ICP-SFMS: 0.3-3.3%; FIA-FLD: 6.5%). Concerning long term precision FIA-ICP-SFMS with on-line IDMS and internal standardization showed the best results (3.1 and 4.6%, respectively) whereas the external calibration of both applied methodological approaches was only in the range of 10 %.The concentrations in the Triton X soluble fraction relative to the applied amount of Indium in the cell culture were in the range of 0.75-1.8% for In-DOTA or 0.30-0.79% for the 2-(4-isothiocyanatobenzyl) - 1,4,7,10-tetraazacyclododecane-N, N', N'', N'''-tetraacetic acid (In-DOTA-Bn) labeled peptide Bβ(15-42). In the Triton X insoluble fraction the relative concentrations of Indium were 0.03-0.18% for the In-DOTA labeled peptide and 0.03-0.13% for Bβ(15-42)-In-DOTA-Bn.
Collapse
Affiliation(s)
- Daniela Kretschy
- University of Natural Resources and Life Sciences, BOKU Vienna, Department of Chemistry, Division of Analytical Chemistry, Muthgasse 18, A-1190 Vienna, Austria
| | - Marion Gröger
- Department of Dermatology, Medical University of Vienna, Spitalgasse 23, A-1090 Vienna, Austria
| | - Daniela Zinkl
- Department of Dermatology, Medical University of Vienna, Spitalgasse 23, A-1090 Vienna, Austria
| | - Peter Petzelbauer
- Department of Dermatology, Medical University of Vienna, Spitalgasse 23, A-1090 Vienna, Austria
| | - Gunda Koellensperger
- University of Natural Resources and Life Sciences, BOKU Vienna, Department of Chemistry, Division of Analytical Chemistry, Muthgasse 18, A-1190 Vienna, Austria
| | - Stephan Hann
- University of Natural Resources and Life Sciences, BOKU Vienna, Department of Chemistry, Division of Analytical Chemistry, Muthgasse 18, A-1190 Vienna, Austria
| |
Collapse
|
11
|
Kretschy D, Koellensperger G, Hann S. Stability assessment of different chelating moieties used for elemental labeling of bio-molecules. Metallomics 2011; 3:1304-9. [PMID: 21922111 DOI: 10.1039/c1mt00114k] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Integrating elemental labeling in quantitative LC-ICP-MS based bio-analysis requires fundamental experiments concerning the stability of complexes during analysis. In a competitive approach complex stability of the chelating moieties 1,4,7,10-tetraazacyclododecane-N,N',N'',N'''-tetraaceticacid (DOTA), 1,4,7-triazacyclononane-N,N',N''-triacetic acid (NOTA) and diethylenetriaminepentaacetic dianhydride (DTPA) in combination with 11 different lanthanides was investigated under typical chromatographic conditions. Measurements were carried out via LC-ICP-QMS using a novel mixed mode separation method. The influence of chromatographic separation, pH and temperature on complex stability constants was assessed regarding further applications of multiplexing in bio-analytical assays. The limit of detection (LOD) for LC-ICP-QMS was 0.03 nM for all investigated Tm complexes (0.15 fmol absolute). Quantification of the complexes was performed via external, flow injection based calibration. For all investigated complexes the stability was significantly decreased by the chromatographic conditions. Moreover, complexation by DOTA revealed two different signals suggesting the presence of a stable intermediate product. Ln(3+)-DOTA and Ln(3+)-NOTA complexes provided high stability at 5 °C and 37 °C over a time of 12 hours, whereas Ln(3+)-DTPA complexes showed significant degradation at 37 °C.
Collapse
Affiliation(s)
- Daniela Kretschy
- University of Natural Resources and Life Sciences, BOKU Vienna, Department of Chemistry, Division of Analytical Chemistry, Vienna, Austria.
| | | | | |
Collapse
|
12
|
Engelhard C. Inductively coupled plasma mass spectrometry: recent trends and developments. Anal Bioanal Chem 2010; 399:213-9. [PMID: 21046089 DOI: 10.1007/s00216-010-4299-y] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2010] [Revised: 09/29/2010] [Accepted: 10/04/2010] [Indexed: 10/18/2022]
Abstract
This year inductively coupled plasma mass spectrometry (ICP-MS) moves into the fourth decade of development. In this article, some recent trends and developments in ICP-MS are reviewed, with special focus on instrumental development and emerging applications. Some key trends include a novel mass spectrometer for elemental and speciation analysis in Mattauch-Herzog geometry with a focal-plane-camera array detector. The reason for this development is the possibility to record the full elemental mass range simultaneously and all the time. Monitoring fast transient signals in chromatography or laser ablation is now possible and will become an important asset in future studies, e.g., for isotope ratio analysis. In addition, there is a lot of new activity and interest in the area of nanosciences and medicine. Here, instrumental developments are reported that allow the direct analysis of microparticles and single cells.
Collapse
Affiliation(s)
- Carsten Engelhard
- Institute of Inorganic and Analytical Chemistry, University of Münster, Corrensstr. 30, 48149 Münster, Germany.
| |
Collapse
|
13
|
Bassioni G, Pillay AE, El Kadi M, Fegali F, Fok SC, Stephen S. Tracking traces of transition metals present in concrete mixtures by inductively-coupled plasma mass spectrometry studies. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2010; 16:679-692. [PMID: 21173466 DOI: 10.1255/ejms.1104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Transition metals can have a significant impact in research related to the dosage optimization of superplasticizers. It is known that the presence of transition metals can influence such doses, and the application of a contemporary instrumental method to obtain the profiles of subsisting transition elements in concrete mixtures would be useful. In this work, inductively-coupled plasma mass spectrometry (ICP-MS) is investigated as a possible tool to track traces of transition metals in concrete mixtures. Depth profiling using ICP-MS on proofed and unproofed concrete shows the presence of Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu and Zn at trace intensities in the bulk of the samples under investigation. The study demonstrates that the transition metals present in the concrete sample are largely a part of the cement composition and, to a minor degree, a result of exposure to the seawater after curing. The coated concrete samples have a metal distribution pattern similar to the uncoated samples, but slight differences in intensity bear testimony to the very low levels that originate from the exposure to seawater. While X-ray diffraction fails to detect these traces of metals, ICP-MS is successful in detecting ultra-trace intensities to parts per trillion. This method is not only a useful application to track traces of transition metals in concrete, but also provides information to estimate the pore size distribution in a given sample by very simple means.
Collapse
Affiliation(s)
- Ghada Bassioni
- The Petroleum Institute, PO Box 2533, Abu Dhabi, United Arab Emirates.
| | | | | | | | | | | |
Collapse
|