1
|
Gholve C, Damle A, Kulkarni S, Banerjee S, Rajan MGR. Evaluation of Different Methods for the Detection of Anti- Thyroglobulin Autoantibody: Prevalence of Anti-Thyroglobulin Autoantibody and Anti-Microsomal Autoantibody in Thyroid Cancer Patients. Indian J Clin Biochem 2022; 37:473-479. [PMID: 36262779 PMCID: PMC9573838 DOI: 10.1007/s12291-021-01005-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Accepted: 09/14/2021] [Indexed: 10/20/2022]
Abstract
Four anti-thyroglobulin autoantibodies (TgAb) assays were evaluated for their reference interval, method agreement, concordance etc. Prevalence of TgAb and anti-thyroid peroxidase was studied in differentiated thyroid cancer (DTC) and control. Reference intervals for TgAb assays varied from method to method due to varied assay designs. For TgAb correlation coefficients ranged from 0.74 to 0.99 whereas concordance ranged from 81 to 96.1%. Prevalence of thyroid antibodies mainly TgAb was increased in DTC primarily in females. Use of sensitive immunoassays is recommended for thyroid autoantibody measurement. Diagnosis and follow-up are difficult in DTC with coexisting thyroid autoimmunity. Hence, careful monitoring with regular surveillance is suggested.
Collapse
Affiliation(s)
- Chandrakala Gholve
- Radiation Medicine Centre, BARC, TMH Annexe, Parel, Mumbai, 400 012 India
| | - Archana Damle
- Radiation Medicine Centre, BARC, TMH Annexe, Parel, Mumbai, 400 012 India
| | - Savita Kulkarni
- Radiation Medicine Centre, BARC, TMH Annexe, Parel, Mumbai, 400 012 India
| | - Sharmila Banerjee
- Radiation Medicine Centre, BARC, TMH Annexe, Parel, Mumbai, 400 012 India
| | - MGR. Rajan
- Radiation Medicine Centre, BARC, TMH Annexe, Parel, Mumbai, 400 012 India
| |
Collapse
|
2
|
Spencer C, Fatemi S. Thyroglobulin antibody (TgAb) methods - Strengths, pitfalls and clinical utility for monitoring TgAb-positive patients with differentiated thyroid cancer. Best Pract Res Clin Endocrinol Metab 2013; 27:701-12. [PMID: 24094640 DOI: 10.1016/j.beem.2013.07.003] [Citation(s) in RCA: 100] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Thyroglobulin autoantibodies (TgAb) are detected at diagnosis or during treatment in approximately 25% of patients with differentiated thyroid cancer (DTC). When present, TgAb interferes with thyroglobulin (Tg) measurement causing falsely low or undetectable Tg immunometric assay (IMA) values that can mask disease. Guidelines mandate that every Tg test have TgAb measured simultaneously and quantitatively by immunoassay and not a recovery test. The propensity and magnitude of TgAb-Tg interference relates to both Tg and TgAb concentrations and the class of Tg method used. Because the TgAb trend reflects changes in thyroid tissue mass, TgAb concentrations serve as a surrogate post-operative DTC tumor marker. A rising, or de novo appearance of TgAb may indicate recurrence, whereas a progressive decline suggests successful treatment. This review focuses on the technical limitations of current TgAb methods, characteristics of TgAb interference with different classes of Tg method, and the clinical value of monitoring TgAb trends as a surrogate DTC tumor marker.
Collapse
Affiliation(s)
- Carole Spencer
- University of Southern California, Los Angeles, CA, USA.
| | | |
Collapse
|
3
|
Ruan M, Shen Y, Chen L, Li M. RECIST 1.1 and serum thyroglobulin measurements in the evaluation of responses to sorafenib in patients with radioactive iodine-refractory differentiated thyroid carcinoma. Oncol Lett 2013; 6:480-486. [PMID: 24137351 PMCID: PMC3789091 DOI: 10.3892/ol.2013.1424] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2012] [Accepted: 06/02/2013] [Indexed: 12/15/2022] Open
Abstract
The present study was designed to investigate the association between response evaluation criteria in solid tumors (RECIST) 1.1 and 1.0, and to explore the utility of thyroglobulin (Tg) measurements in assessing tumor responses to sorafenib in patients with radioactive iodine (RAI)-refractory differentiated thyroid carcinoma (DTC). In total, 23 patients with RAI-refractory DTC were enrolled. A comparison of RECIST 1.1 and 1.0 was performed in all patients with measurable disease. Following the exclusion of patients who were positive for anti-Tg antibody, the correlation between RECIST 1.1 and Tg was investigated in patients with measurable disease, and the concordance of the change in Tg between these patients and the patients with non-measurable disease only was analyzed over time. Tumor responses, assessed by RECIST 1.1 and 1.0, were concordant in 96% of the 23 records. However, the number of target lesions, according to RECIST 1.1, was significantly lower than when using RECIST 1.0. Progressive disease (PD) was identified in one of the five patients who underwent fluorodeoxyglucose-positron emission tomography (FDG-PET)/computed tomography (CT) scanning. A correlation between the Tg levels and the sum of the diameters of the target lesions was verified, with the percentage decrease in Tg levels significantly greater than that in the radiograph, demonstrating shrinkage. Furthermore, the percentage change in Tg levels was consistent between the patients with measurable disease and the subjects with non-measurable disease only. In conclusion, in patients with RAI-refractory DTC, RECIST 1.1 is highly concordant with RECIST 1.0 in the assessment of responses to sorafenib treatment, with the advantage of simplified procedures and the complementary use of FDG-PET. Tg measurements, in concordance with RECIST 1.1, are valuable in the evaluation of tumor responses.
Collapse
Affiliation(s)
- Maomei Ruan
- Department of Nuclear Medicine, Shanghai Sixth People's Hospital, Shanghai Jiao Tong University, Shanghai 200233
| | | | | | | |
Collapse
|
4
|
Vrndic OB, Savin SB, Mijatovic LC, Djukic AA, Jeftic ID, Zivancevic Simonovic ST. Concentration of Thyroglobulin and Thyroglobulin-Specific Autoantibodies in Patients With Differentiated Thyroid Cancer After Treatment With Radioactive Iodine 131. Lab Med 2011. [DOI: 10.1309/lmnc7i58jnjmcpkw] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|
5
|
Abstract
Measuring Thyroglobulin Concentrations in Patients with Differentiated Thyroid CarcinomaThyroid carcinomas are the most common malignant endocrine tumors. Thyroglobulin (Tg), a specific thyroid protein, is the most important tumor marker in thyroid oncology. After total thyroidectomy or radioiodine therapy, detectable or increasing serum Tg levels in patients with differentiated thyroid carcinoma indicate persistence of active thyroid tissue or cancer recurrence. Serum Tg concentration primarily reflects three variables: the mass of differentiated thyroid tissue present; the degree of thyrotropin receptor stimulation and the intrinsic ability of the tumor to synthesize and secrete Tg. Measurement of serum Tg by current immunometric (IMA) and radioimmunological (RIA) assays encounters some methodological problems which can diminish its clinical importance. Discrepancy between the results for Tg using different methods may be caused by: different reference materials, specific properties of the primary and secondary antibodies for antigenic determinants on Tg and diverse binding affinities of these epitopes, together with interference by serum factors (usually antibodies to Tg (TgAb)) with the primary and secondary Tg antibodies from the diagnostic set. In the presence of endogenous TgAb, Tg values measured by immunoradiometric assay (IRMA) and similar assays are usually lower than the real concentrations, while in RIA apparently lower or higher results can be obtained. Falsely low values may lead to delay in necessary treatment, while an inappropriately high Tg value can cause patient anxiety and unnecessary scans. Despite current methodological limitations, serum Tg measurement is a useful test for determining worsening disease and monitoring the effects of therapy in patients who have undergone surgery for differentiated thyroid carcinoma.
Collapse
|
6
|
Huang CC, Hung YL, Shiang YC, Lin TY, Lin YS, Chen CT, Chang HT. Photoassisted Synthesis of Luminescent Mannose-Au Nanodots for the Detection of Thyroglobulin in Serum. Chem Asian J 2010; 5:334-41. [DOI: 10.1002/asia.200900346] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
7
|
Kanai T, Amakawa M, Kato R, Shimizu K, Nakamura K, Ito KI, Hama Y, Fujimori M, Amano J. Evaluation of a new method for the diagnosis of alterations of Lens culinaris agglutinin binding of thyroglobulin molecules in thyroid carcinoma. Clin Chem Lab Med 2009; 47:1285-90. [PMID: 19743952 DOI: 10.1515/cclm.2009.277] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND The measurement of serum thyroglobulin (Tg) is widely used as a marker for recurrence of thyroid carcinoma following total thyroidectomy. However, this method cannot differentiate between benign and malignant disease. We focused on the sugar chain in the Tg molecule and investigated the usefulness of Lens culinaris agglutinin (LCA)-reactive Tg ratios in sera and wash fluids obtained during fine-needle aspiration (FNA) for the detection of thyroid carcinoma. METHODS The study was performed using 203 serum samples (115 from patients with benign thyroid disease and 88 from patients with thyroid carcinomas) and 176 wash fluid samples (143 benign, 21 malignant, and 12 inconclusive). LCA-reactive Tg ratios were determined using an enzyme-linked immunosorbent assay, and a comparison was made between malignant and benign lesions. RESULTS In serum, the ratio in patients with malignancy was 79.5+/-6.0 [mean+/-standard deviation (SD)], significantly lower than in patients with benign lesions (84.9+/-3.5). The ratios in wash fluid from malignant lesions (75.8+/-18.9) were also significantly lower than those from benign lesions (85.6+/-3.9). CONCLUSIONS These results suggest that this method could distinguish between benign and malignant lesions and may be useful for screening serum and wash samples.
Collapse
Affiliation(s)
- Toshiharu Kanai
- Division of Breast and Endocrine Surgery, Department of Surgery (II), Shinshu University School of Medicine, Matsumoto, Japan.
| | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Ma C, Kuang A, Xie J. Radioiodine therapy for differentiated thyroid carcinoma with thyroglobulin positive and radioactive iodine negative metastases. Cochrane Database Syst Rev 2009; 2009:CD006988. [PMID: 19160311 PMCID: PMC7212000 DOI: 10.1002/14651858.cd006988.pub2] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
BACKGROUND Differentiated thyroid carcinoma with thyroglobulin positive and radioactive iodine negative metastases has been observed in follow-up studies. The management of this condition remains controversial. Most studies support blind radioactive iodine treatment while others negate this approach. OBJECTIVES To assess the effects of radioiodine therapy for differentiated thyroid carcinoma with thyroglobulin positive and radioactive iodine negative metastases. SEARCH STRATEGY Studies were obtained from computerised searches of MEDLINE, EMBASE, The Cochrane Library, China National Infrastructure (CNKI) and paper collections of conferences held in Chinese. SELECTION CRITERIA Randomised controlled clinical trials and prospective controlled clinical trials. DATA COLLECTION AND ANALYSIS Two authors independently extracted data and interviewed authors of all potentially relevant studies by electronic mail to verify randomisation procedures. One author entered data into a data extraction form and the second one verified the results of this procedure. MAIN RESULTS Because of the absence of any suitable randomised or prospective controlled trial in this area, results currently cannot be presented. AUTHORS' CONCLUSIONS The currently available evidence is insufficient to reliably assess the potential of radioiodine treatment for differentiated thyroid carcinoma with thyroglobulin positive and radioactive iodine negative metastases.
Collapse
Affiliation(s)
- Chao Ma
- Department of Nuclear Medicine, Affiliated Hospital of Medical College Qingdao University, Jiangsu Road 16, Qingdao, Shandong Province, China, 266003.
| | | | | |
Collapse
|
9
|
Stanojevic M, Savin S, Cvejic D, Djukic A, Jeremic M, Zivancević Simonovic S. Comparison of the influence of thyroglobulin antibodies on serum thyroglobulin values from two different immunoassays in post surgical differentiated thyroid carcinoma patients. J Clin Lab Anal 2009; 23:341-6. [PMID: 19774624 PMCID: PMC6649009 DOI: 10.1002/jcla.20339] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2008] [Accepted: 07/15/2009] [Indexed: 11/07/2022] Open
Abstract
Measurement of serum thyroglobulin (Tg) is a highly specific test in the management of patients with differentiated thyroid cancer (DTC) after surgical treatment. The aim of our study was to evaluate and compare Tg levels in these patients found by radioimmunoassay (RIA) and immunoradiometric assay (IRMA) and to assess the influence of Tg antibodies (TgAbs) on the values obtained for Tg concentration. Both Tg and TgAb were determined postoperatively in the serum of 71 DTC patients using RIA Tg-PEG (INEP) and Tg IRMA (CIS) for Tg, together with TgAb (CIS) for circulating endogenous anti-TgAbs. The obtained concentrations were evaluated statistically. We found a significant difference of Tg concentrations between paired samples from the IRMA and RIA, although the intermethod comparison yielded satisfactory concordance of the two assays (Spearman correlation coefficient -0.792). Positive TgAb was found in 28.2% of the serum samples analyzed. Spearman rank correlation analysis revealed a significant negative relationship between serum TgAb and Tg level measured by IRMA (P=0.02), but not by RIA (P=0.417). On the other hand, our clinical data revealed that 1/18 and 3/18 patients with proven lymph node metastasis had Tg values below the detection limit by RIA and IRMA assay, respectively. Their sera were TgAb positive. We concluded that RIA was less prone to influence of TgAb than IRMA. As the presence of TgAbs may interfere in Tg measurement irrespective of the method selected for determination, this should be considered during the clinical management of these patients.
Collapse
Affiliation(s)
| | - Svetlana Savin
- Institute for the Application of Nuclear Energy INEP, Zemun, Serbia
| | - Dubravka Cvejic
- Institute for the Application of Nuclear Energy INEP, Zemun, Serbia
| | | | | | | |
Collapse
|
10
|
Jahagirdar VR, Strouhal P, Holder G, Gama R, Singh BM. Thyrotoxicosis factitia masquerading as recurrent Graves' disease: endogenous antibody immunoassay interference, a pitfall for the unwary. Ann Clin Biochem 2008; 45:325-7. [PMID: 18482926 DOI: 10.1258/acb.2007.007163] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Antibody interference in immunoassays is an underestimated problem, which has the potential to cause patient harm and waste health-care resources. We report a case where thyroglobulin antibodies generated a false-positive thyroglobulin result delaying the diagnosis of thyrotoxicosis factitia masquerading as recurrent Graves' disease. A high index of clinical suspicion and good laboratory-clinician communication underpins effective clinical and laboratory strategies to detect potentially erroneous laboratory results due to endogenous antibody interference in immunoassays.
Collapse
Affiliation(s)
- V R Jahagirdar
- Department of Diabetes and Endocrinology
- Department of Clinical Chemistry
| | - P Strouhal
- Department of Radiology, New Cross Hospital, Wolverhampton WV10 0QP, UK
| | - G Holder
- Department of Clinical Biochemistry, University Hospital Birmingham, Birmingham B29 6JB, UK
| | - R Gama
- Department of Clinical Chemistry
- Research Institute, Wolverhampton University, West Midlands WY1 1SB, UK
| | - B M Singh
- Department of Diabetes and Endocrinology
| |
Collapse
|
11
|
Sobrero G, Muñoz L, Bazzara L, Martin S, Silvano L, Iorkansky S, Bergoglio L, Spencer C, Miras M. Thyroglobulin reference values in a pediatric infant population. Thyroid 2007; 17:1049-54. [PMID: 17949265 DOI: 10.1089/thy.2007.0059] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Few reports have addressed normal serum thyroglobulin (Tg) values in newborns and infants. In the present study, serum Tg was measured in 228 normal children (110 females and 118 males) aged from 3 to 180 days of life, all presenting normal age-related serum thyrotropin (thyroid-stimulating hormone [TSH]) values and negative anti-Tg and antithyroperoxidase antibodies. Serum Tg was measured by Radioimmunoassay (RIA) (two methods) and Immunometricassay (IMA) (three methods). Mean Tg values measured by the five methods exhibited among-method biases, although a significant positive correlation was observed. Serum Tg levels measured by the five methods showed a correlation with age, but not with TSH or gender. During the first days of life, relatively high mean Tg levels were observed, which progressively decreased until they reached a plateau. Therefore, with the aim of establishing reference values, the population was separated into two age groups: from 3 to 15 days of life (group A) and from 16 to 180 days of life (group B). Mean Tg concentration in group A was statistically higher than in group B. Tg centile distributions were calculated with the aim of establishing the normal levels of serum Tg for each method. We conclude that for a correct interpretation of serum Tg levels, the age and the methods used should be considered.
Collapse
Affiliation(s)
- Gabriela Sobrero
- Servicio de Endocrinología, Hospital de Niños de la Santísima Trinidad, Córdoba, Argentina.
| | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Shimizu K, Nakamura K, Kobatake S, Satomura S, Maruyama M, Kameko F, Tajiri J, Kato R. The clinical utility of Lens culinaris agglutinin-reactive thyroglobulin ratio in serum for distinguishing benign from malignant conditions of the thyroid. Clin Chim Acta 2007; 379:101-4. [PMID: 17270168 DOI: 10.1016/j.cca.2006.12.017] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2006] [Revised: 12/17/2006] [Accepted: 12/20/2006] [Indexed: 11/23/2022]
Abstract
BACKGROUND Traditionally, the follow-up of differentiated thyroid carcinoma consists of periodic withdrawal from L-T4-suppressive therapy to allow performance of a highly sensitive serum Tg measurement to detect recurrences. We investigated Lens culinaris agglutinin-reactive thyroglobulin ratios in serum to evaluate in usefulness for detection of thyroid carcinoma. METHODS The study was conducted on 93 serum sample from 23 healthy volunteers, 32 patients with benign thyroid tumor, 28 patients with thyroid carcinoma without metastasis, and 10 patients with thyroid carcinoma with lymph node metastasis. RESULTS The Lens culinaris Agglutinin reactive thyroglobulin ratio in patients with thyroid carcinoma was significantly lower than in patients with benign thyroid tumor with serum thyroglobulin concentration >200 ng/ml. Among cases of thyroid carcinoma with lymph node metastasis, Lens culinaris Agglutinin reactive thyroglobulin ratios were significantly lower than in patient with thyroid carcinoma without metastasis and those with benign tumor regardless of serum thyroglobulin concentration. CONCLUSION Measurement of Lens culinaris Agglutinin reactive thyroglobulin ratio in serum may be useful for distinguishing between thyroid carcinoma and benign thyroid tumor.
Collapse
Affiliation(s)
- Kayoko Shimizu
- Diagnostics Research Laboratories, Wako Pure Chemical Industries, Ltd., Japan.
| | | | | | | | | | | | | | | |
Collapse
|
13
|
Iervasi A, Iervasi G, Carpi A, Zucchelli GC. Serum thyroglobulin measurement: clinical background and main methodological aspects with clinical impact. Biomed Pharmacother 2006; 60:414-24. [PMID: 16959467 DOI: 10.1016/j.biopha.2006.07.007] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
It is worldwide recognized that circulating thyroglobulin (Tg) measurement represents a fundamental tool in the follow-up of patients affected by differentiated thyroid cancer (DTC). In the last American and European Consensus Conferences, a surveillance guideline has been extended to the use of thyrotropin (TSH)-stimulated Tg levels for thyroidectomized patients without clinical evidence of residual tumor with Tg below 1 microg/l during TSH suppression. Therefore, sensitivity of the methods is critical to detect small amounts of Tg and/or to observe minimal changes in Tg concentration in the management of DTC patients. It has been proposed that only methods providing the greatest distinction between the lower limit of euthyroid reference range (approximately 3.0 microg/l) and the functional sensitivity limit (at least 1 microg/l) of the assay may offer a suitable clinical sensitivity for detecting small amounts of functioning thyroid tissue in TSH-suppressed state (1 g of normal thyroid tissue results in a serum Tg of approximately 1 microg/l when TSH is normal and about 0.5 microg/l when TSH is suppressed). In the last 30 years sensitivity of Tg measurements has been greatly improved, nowadays methods can achieve very good analytical and functional sensitivity to give reliable results also in the very low concentration range (between 0.1 and 1 microg/l). In addition, with the introduction of fully automated assays, results can be readily available to the clinician while patients are still in the ambulatory area. However, despite the large clinical use of Tg measurement, wide differences (by threefold) still remain between results produced in different laboratories due to poor standardization, heterogeneity of circulating Tg, interference from auto-antibodies, differences in the epitope recognition by antibodies used in the assays.
Collapse
Affiliation(s)
- A Iervasi
- National Council of Research, Institute of Clinical Physiology, Via Moruzzi, Pisa, Italy.
| | | | | | | |
Collapse
|
14
|
Abstract
Thyroglobulin measurements in tissue and serum play an integral role in the evaluation of patients who have thyroid cancer. Immunohistochemical detection of thyroglobulin in surgical specimens is useful in the differential diagnosis of tumors of unknown origin; however, the most important application of thyroglobulin measurement in clinical practice is in the postsurgical management of differentiated thyroid cancer. Serum thyroglobulin is a highly specific and sensitive tumor marker for detecting persistent or recurrent thyroid cancer and for monitoring clinical status. The reappearance of circulating thyroglobulin after total thyroid ablation is pathognomonic for the presence of tumor. The measurement of thyroglobulin in serum is challenging, however, and several analytical problems limit assay performance. Thyroglobulin autoantibody interference is a particularly significant concern that requires all thyroglobulin samples to be screened for their presence. No immunoassay is totally free from interference by thyroglobulin autoantibodies. Measurement of thyroglobulin mRNA to detect circulating tumor cells may help to overcome some of the limitations of current protein-detection methods; serum thyroglobulin will continue to remain the "gold standard." The complex functional features of thyroid carcinomas make sole reliance upon any one diagnostic technique, including thyroglobulin assessments, potentially misleading. Thyroglobulin measurements are a critical component of a multifaceted diagnostic approach to this disease.
Collapse
Affiliation(s)
- Ronald J Whitley
- Department of Pathology and Laboratory Medicine, 800 Rose Street, University of Kentucky, Lexington, KY 40536-02963, USA.
| | | |
Collapse
|
15
|
Mazzaferri EL, Robbins RJ, Spencer CA, Braverman LE, Pacini F, Wartofsky L, Haugen BR, Sherman SI, Cooper DS, Braunstein GD, Lee S, Davies TF, Arafah BM, Ladenson PW, Pinchera A. A consensus report of the role of serum thyroglobulin as a monitoring method for low-risk patients with papillary thyroid carcinoma. J Clin Endocrinol Metab 2003; 88:1433-41. [PMID: 12679418 DOI: 10.1210/jc.2002-021702] [Citation(s) in RCA: 353] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Recent studies have provided new information regarding the optimal surveillance protocols for low-risk patients with differentiated thyroid cancer (DTC). This article summarizes the main issues brought out in a consensus conference of thyroid cancer specialists who analyzed and discussed this new data. There is growing recognition of the value of serum thyroglobulin (Tg) as part of routine surveillance. An undetectable serum Tg measured during thyroid hormone suppression of TSH (THST) is often misleading. Eight studies show that 21% of 784 patients who had no clinical evidence of tumor with baseline serum Tg levels usually below 1 micro g/liter during THST had, in response to recombinant human TSH (rhTSH), a rise in serum Tg to more than 2 micro g/liter. When this happened, 36% of the patients were found to have metastases (36% at distant sites) that were identified in 91% by an rhTSH-stimulated Tg above 2 micro g/liter. Diagnostic whole body scanning, after either rhTSH or thyroid hormone withdrawal, identified only 19% of the cases of metastases. Ten studies comprising 1599 patients demonstrate that a TSH-stimulated Tg test using a Tg cutoff of 2 micro g/liter (either after thyroid hormone withdrawal or 72 h after rhTSH) is sufficiently sensitive to be used as the principal test in the follow-up management of low-risk patients with DTC and that the routine use of diagnostic whole body scanning in follow-up should be discouraged. On the basis of the foregoing, we propose a surveillance guideline using TSH-stimulated Tg levels for patients who have undergone total or near-total thyroidectomy and (131)I ablation for DTC and have no clinical evidence of residual tumor with a serum Tg below 1 micro g/liter during THST.
Collapse
Affiliation(s)
- E L Mazzaferri
- Division of Endocrinology, Shands Hospital, Gainesville, Florida 32610, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Affiliation(s)
- Anthony Toft
- Endocrine Clinic and University Department of Clinical Biochemistry, Royal Infirmary, Edinburgh EH3 9YW, UK.
| | | |
Collapse
|