Seehofnerová A, Kok M, Mihl C, Douwes D, Sailer A, Nijssen E, de Haan MJW, Wildberger JE, Das M. Feasibility of low contrast media volume in CT angiography of the aorta. Eur J Radiol Open 2015; 2:58-65. [PMID: 26937437 PMCID: PMC4750622 DOI: 10.1016/j.ejro.2015.03.001] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2014] [Revised: 03/01/2015] [Accepted: 03/02/2015] [Indexed: 11/22/2022] Open
Abstract
Objectives Using smaller volumes of contrast media (CM) in CT angiography (CTA) is desirable in terms of cost reduction and prevention of contrast-induced nephropathy (CIN). The purpose was to evaluate the feasibility of low CM volume in CTA of the aorta. Methods 77 patients referred for CTA of the aorta were scanned using a standard MDCT protocol at 100 kV. A bolus of 50 ml CM (Iopromide 300 mg Iodine/ml) at a flow rate of 6 ml/s was applied (Iodine delivery rate IDR = 1.8 g/s; Iodine load 15 g) followed by a saline bolus of 40 ml at the same flow rate. Scan delay was determined by the test bolus method. Subjective image quality was assessed and contrast enhancement was measured at 10 anatomical levels of the aorta. Results Diagnostic quality images were obtained for all patients, reaching a mean overall contrast enhancement of 324 ± 28 HU. Mean attenuation was 350 ± 60 HU at the thoracic aorta and 315 ± 83 HU at the abdominal aorta. Conclusions A straightforward low volume CM protocol proved to be technically feasible and led to CTA examinations reaching diagnostic image quality of the aorta at 100 kV. Based on these findings, the use of a relatively small CM bolus can be incorporated into routine clinical imaging.
Collapse
Affiliation(s)
- Anna Seehofnerová
- Department of Radiology, Maastricht University Medical Centre, P. Debyelaan 25, PO Box 5800, 6202 AZ Maastricht, The Netherlands
| | - Madeleine Kok
- Department of Radiology, Maastricht University Medical Centre, P. Debyelaan 25, PO Box 5800, 6202 AZ Maastricht, The Netherlands; CARIM School for Cardiovascular Diseases, Maastricht University Medical Centre, Maastricht, The Netherlands
| | - Casper Mihl
- Department of Radiology, Maastricht University Medical Centre, P. Debyelaan 25, PO Box 5800, 6202 AZ Maastricht, The Netherlands; CARIM School for Cardiovascular Diseases, Maastricht University Medical Centre, Maastricht, The Netherlands
| | - Dave Douwes
- Siemens Nederland N.V., Healthcare Sector, Customer Service Prinses Beatrixlaan 800, 2595 BN Den Haag, The Netherlands
| | - Anni Sailer
- Department of Radiology, Maastricht University Medical Centre, P. Debyelaan 25, PO Box 5800, 6202 AZ Maastricht, The Netherlands; CARIM School for Cardiovascular Diseases, Maastricht University Medical Centre, Maastricht, The Netherlands
| | - Estelle Nijssen
- Department of Radiology, Maastricht University Medical Centre, P. Debyelaan 25, PO Box 5800, 6202 AZ Maastricht, The Netherlands; CARIM School for Cardiovascular Diseases, Maastricht University Medical Centre, Maastricht, The Netherlands
| | - Michiel J W de Haan
- Department of Radiology, Maastricht University Medical Centre, P. Debyelaan 25, PO Box 5800, 6202 AZ Maastricht, The Netherlands; CARIM School for Cardiovascular Diseases, Maastricht University Medical Centre, Maastricht, The Netherlands
| | - Joachim E Wildberger
- Department of Radiology, Maastricht University Medical Centre, P. Debyelaan 25, PO Box 5800, 6202 AZ Maastricht, The Netherlands; CARIM School for Cardiovascular Diseases, Maastricht University Medical Centre, Maastricht, The Netherlands
| | - Marco Das
- Department of Radiology, Maastricht University Medical Centre, P. Debyelaan 25, PO Box 5800, 6202 AZ Maastricht, The Netherlands; CARIM School for Cardiovascular Diseases, Maastricht University Medical Centre, Maastricht, The Netherlands
| |
Collapse
|