Puvanasunthararajah S, Camps SM, Wille ML, Fontanarosa D. Deep learning-based ultrasound transducer induced CT metal artifact reduction using generative adversarial networks for ultrasound-guided cardiac radioablation. Phys Eng Sci Med 2023; 46:1399-1410. [PMID: 37548887 DOI: 10.1007/s13246-023-01307-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Accepted: 07/20/2023] [Indexed: 08/08/2023]
Abstract
In US-guided cardiac radioablation, a possible workflow includes simultaneous US and planning CT acquisitions, which can result in US transducer-induced metal artifacts on the planning CT scans. To reduce the impact of these artifacts, a metal artifact reduction (MAR) algorithm has been developed based on a deep learning Generative Adversarial Network called Cycle-MAR, and compared with iMAR (Siemens), O-MAR (Philips) and MDT (ReVision Radiology), and CCS-MAR (Combined Clustered Scan-based MAR). Cycle-MAR was trained with a supervised learning scheme using sets of paired clinical CT scans with and without simulated artifacts. It was then evaluated on CT scans with real artifacts of an anthropomorphic phantom, and on sets of clinical CT scans with simulated artifacts which were not used for Cycle-MAR training. Image quality metrics and HU value-based analysis were used to evaluate the performance of Cycle-MAR compared to the other algorithms. The proposed Cycle-MAR network effectively reduces the negative impact of the metal artifacts. For example, the calculated HU value improvement percentage for the cardiac structures in the clinical CT scans was 59.58%, 62.22%, and 72.84% after MDT, CCS-MAR, and Cycle-MAR application, respectively. The application of MAR algorithms reduces the impact of US transducer-induced metal artifacts on CT scans. In comparison to iMAR, O-MAR, MDT, and CCS-MAR, the application of developed Cycle-MAR network on CT scans performs better in reducing these metal artifacts.
Collapse
Affiliation(s)
- Sathyathas Puvanasunthararajah
- School of Clinical Sciences, Queensland University of Technology, Brisbane, QLD, Australia.
- Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, Australia.
| | | | - Marie-Luise Wille
- Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, Australia
- School of Mechanical, Medical & Process Engineering, Faculty of Engineering, Queensland University of Technology, Brisbane, QLD, Australia
- ARC ITTC for Multiscale 3D Imaging, Modelling, and Manufacturing, Queensland University of Technology, Brisbane, QLD, Australia
| | - Davide Fontanarosa
- School of Clinical Sciences, Queensland University of Technology, Brisbane, QLD, Australia
- Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, Australia
| |
Collapse
|
2
|
Katsura K, Tanabe S, Nakano H, Sakai M, Ohta A, Kaidu M, Soga M, Kobayashi T, Takamura M, Hayashi T. The Relationship between the Contouring Time of the Metal Artifacts Area and Metal Artifacts in Head and Neck Radiotherapy. Tomography 2023; 9:98-104. [PMID: 36648996 PMCID: PMC9844309 DOI: 10.3390/tomography9010009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Revised: 01/06/2023] [Accepted: 01/08/2023] [Indexed: 01/13/2023] Open
Abstract
(1) Background: The impacts of metal artifacts (MAs) on the contouring workload for head and neck radiotherapy have not yet been clarified. Therefore, this study evaluated the relationship between the contouring time of the MAs area and MAs on head and neck radiotherapy treatment planning. (2) Methods: We used treatment planning computed tomography (CT) images for head and neck radiotherapy. MAs were classified into three severities by the percentage of CT images containing MAs: mild (<25%), moderate (25−75%), and severe (>75%). We randomly selected nine patients to evaluate the relationship between MAs and the contouring time of the MAs area. (3) Results: The contouring time of MAs showed moderate positive correlations with the MAs volume and the number of CT images containing MAs. Interobserver reliability of the extracted MAs volume and contouring time were excellent and poor, respectively. (4) Conclusions: Our study suggests that the contouring time of MAs areas is related to individual commitment rather than clinical experience. Therefore, the development of software combining metal artifact reduction methods with automatic contouring methods is necessary to reducing interobserver variability and contouring workload.
Collapse
Affiliation(s)
- Kouji Katsura
- Department of Oral Radiology, Niigata University Medical and Dental Hospital, Niigata 951-8520, Japan
- Division of Oral and Maxillofacial Radiology, Faculty of Dentistry & Graduate School of Medical and Dental Sciences, Niigata University, Niigata 951-8514, Japan
- Correspondence: ; Tel.: +81-25-227-2914
| | - Satoshi Tanabe
- Division of Radiation Oncology, Niigata University Medical and Dental Hospital, Niigata 851-8520, Japan
| | - Hisashi Nakano
- Division of Radiation Oncology, Niigata University Medical and Dental Hospital, Niigata 851-8520, Japan
| | - Madoka Sakai
- Department of Radiology and Radiation Oncology, Graduate School of Medical and Dental Sciences, Niigata University, Niigata 951-8514, Japan
| | - Atsushi Ohta
- Department of Radiology and Radiation Oncology, Graduate School of Medical and Dental Sciences, Niigata University, Niigata 951-8514, Japan
| | - Motoki Kaidu
- Department of Radiology and Radiation Oncology, Graduate School of Medical and Dental Sciences, Niigata University, Niigata 951-8514, Japan
| | - Marie Soga
- Department of Oral Radiology, Niigata University Medical and Dental Hospital, Niigata 951-8520, Japan
| | - Taichi Kobayashi
- Division of Oral and Maxillofacial Radiology, Faculty of Dentistry & Graduate School of Medical and Dental Sciences, Niigata University, Niigata 951-8514, Japan
| | - Masaki Takamura
- Division of Oral and Maxillofacial Radiology, Faculty of Dentistry & Graduate School of Medical and Dental Sciences, Niigata University, Niigata 951-8514, Japan
| | - Takafumi Hayashi
- Department of Oral Radiology, Niigata University Medical and Dental Hospital, Niigata 951-8520, Japan
- Division of Oral and Maxillofacial Radiology, Faculty of Dentistry & Graduate School of Medical and Dental Sciences, Niigata University, Niigata 951-8514, Japan
| |
Collapse
|
3
|
Puvanasunthararajah S, Camps SM, Wille ML, Fontanarosa D. Combined clustered scan-based metal artifact reduction algorithm (CCS-MAR) for ultrasound-guided cardiac radioablation. Phys Eng Sci Med 2022; 45:1273-1287. [PMID: 36352318 DOI: 10.1007/s13246-022-01192-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Accepted: 10/20/2022] [Indexed: 11/11/2022]
Abstract
Cardiac radioablation is a promising treatment for cardiac arrhythmias, but accurate dose delivery can be affected by heart motion. For this reason, real-time cardiac motion monitoring during radioablation is of paramount importance. Real-time ultrasound (US) guidance can be a solution. The US-guided cardiac radioablation workflow can be simplified by the simultaneous US and planning computed tomography (CT) acquisition, which can result in US transducer-induced metal artifacts on the planning CT scans. To reduce the impact of these artifacts, a new metal artifact reduction (MAR) algorithm (named: Combined Clustered Scan-based MAR [CCS-MAR]) has been developed and compared with iMAR (Siemens), O-MAR (Philips) and MDT (ReVision Radiology) algorithms. CCS-MAR is a fully automated sinogram inpainting-based MAR algorithm, which uses a two-stage correction process based on a normalized MAR method. The second stage aims to correct errors remaining from the first stage to create an artifact-free combined clustered scan for the process of metal artifact reduction. To evaluate the robustness of CCS-MAR, conventional CT scans and/or dual-energy CT scans from three anthropomorphic phantoms and transducers with different sizes were used. The performance of CCS-MAR for metal artifact reduction was compared with other algorithms through visual comparison, image quality metrics analysis, and HU value restoration evaluation. The results of this study show that CCS-MAR effectively reduced the US transducer-induced metal artifacts and that it improved HU value accuracy more or comparably to other MAR algorithms. These promising results justify future research into US transducer-induced metal artifact reduction for the US-guided cardiac radioablation purposes.
Collapse
Affiliation(s)
- Sathyathas Puvanasunthararajah
- School of Clinical Sciences, Queensland University of Technology, Brisbane, QLD, Australia. .,Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, Australia.
| | | | - Marie-Luise Wille
- Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, Australia.,School of Mechanical, Medical & Process Engineering, Faculty of Engineering, Queensland University of Technology, Brisbane, QLD, Australia.,ARC ITTC for Multiscale 3D Imaging, Modelling, and Manufacturing, Queensland University of Technology, Brisbane, QLD, Australia
| | - Davide Fontanarosa
- School of Clinical Sciences, Queensland University of Technology, Brisbane, QLD, Australia.,Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, Australia
| |
Collapse
|
4
|
King J, Whittam S, Smith D, Al-Qaisieh B. The Impact of a Metal Artefact Reduction Algorithm on Treatment Planning for Patients Undergoing Radiotherapy of the Pelvis. Phys Imaging Radiat Oncol 2022; 24:138-143. [DOI: 10.1016/j.phro.2022.11.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 11/08/2022] [Accepted: 11/08/2022] [Indexed: 11/13/2022] Open
|
5
|
Yadav P, Chang SX, Cheng CW, DesRosiers CM, Mitra RK, Das IJ. Dosimetric evaluation of high-Z inhomogeneity used for hip prosthesis: A multi-institutional collaborative study. Phys Med 2022; 95:148-155. [PMID: 35182937 DOI: 10.1016/j.ejmp.2022.02.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Accepted: 02/04/2022] [Indexed: 01/27/2023] Open
Abstract
PURPOSE A multi-institutional investigation for dosimetric evaluation of high-Z hip prosthetic device in photon beam. METHODS A bilateral hip prosthetic case was chosen. An in-house phantom was built to replicate the human pelvis with two different prostheses. Dosimetric parameters: dose to the target and organs at risk (OARs) were compared for the clinical case generated by various treatment planning system (TPS) with varied algorithms. Single beam plans with different TPS for phantom using 6 MV and 15 MV photon beams with and without density correction were compared with measurement. RESULTS Wide variations in target and OAR dosimetry were recorded for different TPS. For clinical case ideal PTV coverage was noted for plans generated with Corvus and Prowess TPS only. However, none of the TPS were able to meet plan objective for the bladder. Good correlation was noticed for the measured and the Pinnacle TPS for corrected dose calculation at the interfaces as well as the dose ratio in elsewhere. On comparing measured and calculated dose, the difference across the TPS varied from -20% to 60% for 6 MV and 3% to 50% for the 15 MV, respectively. CONCLUSION Most TPS do not provide accurate dosimetry with high-Z prosthesis. It is important to check the TPS under extreme conditions of beams passing through the high-Z region. Metal artifact reduction algorithms may reduce the difference between the measured and calculated dose but still significant differences exist. Further studies are required to validate the calculational accuracy.
Collapse
Affiliation(s)
- Poonam Yadav
- Department of Radiation Oncology, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Chicago, IL 60611, USA
| | - Sha X Chang
- Department of Radiation Oncology, University of North Carolina School of Medicine, Chapel Hill, NC 27599, USA
| | - Chee-Wai Cheng
- Department of Radiation Oncology, University Hospitals Cleveland Medical Center, Cleveland, OH 46255, USA
| | - Colleen M DesRosiers
- Department of Radiation Oncology, Indiana University Health, Indianapolis, IN 46202, USA
| | - Raj K Mitra
- Department of Radiation Oncology, Ochsner Health System, New Orleans, LA 70121, USA
| | - Indra J Das
- Department of Radiation Oncology, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Chicago, IL 60611, USA.
| |
Collapse
|
6
|
Vara G, Ceccarelli L, Ponti F, Miceli M, Golfieri R, Facchini G. Reduction of Metal Artifacts Caused by Titanium Peduncular Screws in the Spine by Means of Monoenergetic Images and the Metal Artifact Reduction Software in Dual-Energy Computed Tomography. J Med Phys 2022; 47:152-158. [PMID: 36212200 PMCID: PMC9543003 DOI: 10.4103/jmp.jmp_121_21] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Revised: 03/08/2022] [Accepted: 03/09/2022] [Indexed: 11/04/2022] Open
|
7
|
Nakamura M, Nakao M, Imanishi K, Hirashima H, Tsuruta Y. Geometric and dosimetric impact of 3D generative adversarial network-based metal artifact reduction algorithm on VMAT and IMPT for the head and neck region. Radiat Oncol 2021; 16:96. [PMID: 34092240 PMCID: PMC8182914 DOI: 10.1186/s13014-021-01827-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Accepted: 05/28/2021] [Indexed: 11/26/2022] Open
Abstract
Background We investigated the geometric and dosimetric impact of three-dimensional (3D) generative adversarial network (GAN)-based metal artifact reduction (MAR) algorithms on volumetric-modulated arc therapy (VMAT) and intensity-modulated proton therapy (IMPT) for the head and neck region, based on artifact-free computed tomography (CT) volumes with dental fillings. Methods Thirteen metal-free CT volumes of the head and neck regions were obtained from The Cancer Imaging Archive. To simulate metal artifacts on CT volumes, we defined 3D regions of the teeth for pseudo-dental fillings from the metal-free CT volumes. HU values of 4000 HU were assigned to the selected teeth region of interest. Two different CT volumes, one with four (m4) and the other with eight (m8) pseudo-dental fillings, were generated for each case. These CT volumes were used as the Reference. CT volumes with metal artifacts were then generated from the Reference CT volumes (Artifacts). On the Artifacts CT volumes, metal artifacts were manually corrected for using the water density override method with a value of 1.0 g/cm3 (Water). By contrast, the CT volumes with reduced metal artifacts using 3D GAN model extension of CycleGAN were also generated (GAN-MAR). The structural similarity (SSIM) index within the planning target volume was calculated as quantitative error metric between the Reference CT volumes and the other volumes. After creating VMAT and IMPT plans on the Reference CT volumes, the reference plans were recalculated for the remaining CT volumes. Results The time required to generate a single GAN-MAR CT volume was approximately 30 s. The median SSIMs were lower in the m8 group than those in the m4 group, and ANOVA showed a significant difference in the SSIM for the m8 group (p < 0.05). Although the median differences in D98%, D50% and D2% were larger in the m8 group than the m4 group, those from the reference plans were within 3% for VMAT and 1% for IMPT. Conclusions The GAN-MAR CT volumes generated in a short time were closer to the Reference CT volumes than the Water and Artifacts CT volumes. The observed dosimetric differences compared to the reference plan were clinically acceptable.
Collapse
Affiliation(s)
- Mitsuhiro Nakamura
- Division of Medical Physics, Department of Information Technology and Medical Engineering, Human Health Sciences, Graduate School of Medicine, Kyoto University, 53 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan. .,Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
| | - Megumi Nakao
- Department of Systems Science, Graduate School of Informatics, Kyoto University, Kyoto, Japan
| | | | - Hideaki Hirashima
- Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Yusuke Tsuruta
- Division of Medical Physics, Department of Information Technology and Medical Engineering, Human Health Sciences, Graduate School of Medicine, Kyoto University, 53 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan.,Division of Clinical Radiology Service, Kyoto University Hospital, Kyoto, Japan
| |
Collapse
|
8
|
Puvanasunthararajah S, Fontanarosa D, Wille M, Camps SM. The application of metal artifact reduction methods on computed tomography scans for radiotherapy applications: A literature review. J Appl Clin Med Phys 2021; 22:198-223. [PMID: 33938608 PMCID: PMC8200502 DOI: 10.1002/acm2.13255] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Revised: 03/21/2021] [Accepted: 03/30/2021] [Indexed: 12/22/2022] Open
Abstract
Metal artifact reduction (MAR) methods are used to reduce artifacts from metals or metal components in computed tomography (CT). In radiotherapy (RT), CT is the most used imaging modality for planning, whose quality is often affected by metal artifacts. The aim of this study is to systematically review the impact of MAR methods on CT Hounsfield Unit values, contouring of regions of interest, and dose calculation for RT applications. This systematic review is performed in accordance with the PRISMA guidelines; the PubMed and Web of Science databases were searched using the main keywords "metal artifact reduction", "computed tomography" and "radiotherapy". A total of 382 publications were identified, of which 40 (including one review article) met the inclusion criteria and were included in this review. The selected publications (except for the review article) were grouped into two main categories: commercial MAR methods and research-based MAR methods. Conclusion: The application of MAR methods on CT scans can improve treatment planning quality in RT. However, none of the investigated or proposed MAR methods was completely satisfactory for RT applications because of limitations such as the introduction of other errors (e.g., other artifacts) or image quality degradation (e.g., blurring), and further research is still necessary to overcome these challenges.
Collapse
Affiliation(s)
- Sathyathas Puvanasunthararajah
- School of Clinical SciencesQueensland University of TechnologyBrisbaneQLDAustralia
- Centre for Biomedical TechnologiesQueensland University of TechnologyBrisbaneQLDAustralia
| | - Davide Fontanarosa
- School of Clinical SciencesQueensland University of TechnologyBrisbaneQLDAustralia
- Centre for Biomedical TechnologiesQueensland University of TechnologyBrisbaneQLDAustralia
| | - Marie‐Luise Wille
- Centre for Biomedical TechnologiesQueensland University of TechnologyBrisbaneQLDAustralia
- School of MechanicalMedical & Process EngineeringFaculty of EngineeringQueensland University of TechnologyBrisbaneQLDAustralia
- ARC ITTC for Multiscale 3D Imaging, Modelling, and ManufacturingQueensland University of TechnologyBrisbaneQLDAustralia
| | | |
Collapse
|
9
|
Khaleghi G, Hosntalab M, Sadeghi M, Reiazi R, Mahdavi SR. Metal artifact reduction in computed tomography images based on developed generative adversarial neural network. INFORMATICS IN MEDICINE UNLOCKED 2021. [DOI: 10.1016/j.imu.2021.100573] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
10
|
Koike Y, Anetai Y, Takegawa H, Ohira S, Nakamura S, Tanigawa N. Deep learning-based metal artifact reduction using cycle-consistent adversarial network for intensity-modulated head and neck radiation therapy treatment planning. Phys Med 2020; 78:8-14. [DOI: 10.1016/j.ejmp.2020.08.018] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Revised: 08/17/2020] [Accepted: 08/18/2020] [Indexed: 01/27/2023] Open
|
11
|
Nielsen JS, Edmund JM, Van Leemput K. Magnetic resonance-based computed tomography metal artifact reduction using Bayesian modelling. Phys Med Biol 2019; 64:245012. [PMID: 31766033 DOI: 10.1088/1361-6560/ab5b70] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Metal artifact reduction (MAR) algorithms reduce the errors caused by metal implants in x-ray computed tomography (CT) images and are an important part of error management in radiotherapy. A promising MAR approach is to leverage the information in magnetic resonance (MR) images that can be acquired for organ or tumor delineation. This is however complicated by the ambiguous relationship between CT values and conventional-sequence MR intensities as well as potential co-registration issues. In order to address these issues, this paper proposes a self-tuning Bayesian model for MR-based MAR that combines knowledge of the MR image intensities in local spatial neighborhoods with the information in an initial, corrupted CT reconstructed using filtered back projection. We demonstrate the potential of the resulting model in three widely-used MAR scenarios: image inpainting, sinogram inpainting and model-based iterative reconstruction. Compared to conventional alternatives in a retrospective study on nine head-and-neck patients with CT and T1-weighted MR scans, we find improvements in terms of image quality and quantitative CT value accuracy within each scenario. We conclude that the proposed model provides a versatile way to use the anatomical information in a co-acquired MR scan to boost the performance of MAR algorithms.
Collapse
Affiliation(s)
- Jonathan Scharff Nielsen
- Department of Health Technology, Technical University of Denmark, 2820 Lyngby, Denmark. Radiotherapy Research Unit, Department of Oncology, Gentofte and Herlev Hospital, University of Copenhagen, 2730 Herlev, Denmark
| | | | | |
Collapse
|
12
|
Akdeniz Y, Yegingil I, Yegingil Z. Effects of metal implants and a metal artifact reduction tool on calculation accuracy of AAA and Acuros XB algorithms in small fields. Med Phys 2019; 46:5326-5335. [PMID: 31508819 DOI: 10.1002/mp.13819] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2019] [Revised: 08/28/2019] [Accepted: 09/04/2019] [Indexed: 11/05/2022] Open
Abstract
PURPOSE In this study, the dosimetric accuracy of analytical anisotropic algorithm (AAA) and Acuros XB (AXB) dose calculation algorithms (Varian Medical Systems, Palo Alto, CA) was investigated for small radiation fields incident on phantoms of various metals that include stainless steel grade 316L (SS316L) and titanium alloy grade 5 (Ti5) implants. In addition, the effects of using metal artifact reduction for orthopedic implants (O-MAR, Philips Healthcare, Cleveland, OH) were evaluated. METHODS The evaluations of AAA and AXB were performed by comparing the crossline profiles calculated by AAA and AXB with GafChromicTM EBT3 film measurements at the phantom-implant interfaces and in close vicinity of implant materials for small field sizes (1 × 1 cm2 , 2 × 2 cm2 , 3 × 3 cm2 , and 4 × 4 cm2 ) of a 6 MV flattening filter free photon beam. O-MAR corrected and uncorrected (UC) computed tomography (CT) images were used for dose calculations. The values of average and standard deviations (SD) of Hounsfield unit (HU) for selected regions of each case were evaluated. The differences in average dose percentages in defined regions were calculated to quantify the relative dosimetric changes between doses calculated on UC and O-MAR corrected CT images. RESULTS Compared to UC images, the values of SD were reduced, and the average HU became closer to its reference value in the O-MAR images. There was some discrepancy in average dose percentage differences between calculations using UC and O-MAR images at 1 cm above the SS316L implant (average dose percentage differences were AXB/UC = 5.9% and AXB/O-MAR = -1.2%; AAA/UC = 2.2%, and AAA/O-MAR = -0.8%). Neither AAA nor AXB algorithms predict increase in dose at upper phantom-implant interface (4.9%, 9.9%. 13.5%, and 13.8% for the fields from 1 × 1 cm2 to 4 × 4 cm2 , respectively). At the side of the SS316L implant (where dark streak artifacts exist), dose difference averages were estimated as - 1.1% and 22.3% when AXB/O-MAR and AXB/UC calculations are compared with EBT3 measurements, respectively. Dose predictions at 1 cm below the SS316L implant were underestimated by AXB/O-MAR (average -0.5%) and AXB/UC (average 2.0%). CONCLUSIONS The O-MAR tool was shown to have a favorable dosimetric effect or no effect on the calculations in the upper proximity of the implant materials. The dose differences between EBT3 film measurements and calculations at upper phantom-implant interfaces were smaller when they were calculated using O-MAR images. However, the dose differences increased when O-MAR corrected images were used for AAA calculations at lower phantom-implant interfaces. Use of O-MAR enabled closer agreement for the AXB algorithm, especially in the dark streak artifact regions. The O-MAR algorithm should be used when the dose is calculated with the AXB algorithm in cases of patients with the metal implants. The estimations using AAA and AXB algorithms, in phantom setups, with Ti5 implant material were found to be closer to the EBT3 film measurements, when compared with the same estimations using SS316L implant material.
Collapse
Affiliation(s)
- Yucel Akdeniz
- Department of Radiation Oncology, Acıbadem Adana Hospital, Seyhan, Adana, 01130, Turkey
| | - Ilhami Yegingil
- Department of Electrical and Electronics Engineering, Faculty of Engineering, Hasan Kalyoncu University, Gaziantep, Turkey
| | - Zehra Yegingil
- Department of Physics, Faculty of Science and Letters, Cukurova University, Saricam, Adana, 01330, Turkey
| |
Collapse
|
13
|
Nielsen JS, Van Leemput K, Edmund JM. MR-based CT metal artifact reduction for head-and-neck photon, electron, and proton radiotherapy. Med Phys 2019; 46:4314-4323. [PMID: 31332792 PMCID: PMC6802740 DOI: 10.1002/mp.13729] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Revised: 06/24/2019] [Accepted: 07/06/2019] [Indexed: 11/30/2022] Open
Abstract
Purpose We investigated the impact on computed tomography (CT) image quality and photon, electron, and proton head‐and‐neck (H&N) radiotherapy (RT) dose calculations of three CT metal artifact reduction (MAR) approaches: A CT‐based algorithm (oMAR Philips Healthcare), manual water override, and our recently presented, Magnetic Resonance (MR)‐based kerMAR algorithm. We considered the following three hypotheses: I: Manual water override improves MAR over the CT‐ and MR‐based alternatives; II: The automatic algorithms (oMAR and kerMAR) improve MAR over the uncorrected CT; III: kerMAR improves MAR over oMAR. Methods We included a veal shank phantom with/without six metal inserts and nine H&N RT patients with dental implants. We quantified the MAR capabilities by the reduction of outliers in the CT value distribution in regions of interest, and the change in particle range and photon depth at maximum dose. Results Water override provided apparent image improvements in the soft tissue region but insignificantly or negatively influenced the dose calculations. We however found significant improvements in image quality and particle range impact, compared to the uncorrected CT, when using oMAR and kerMAR. kerMAR in turn provided superior improvements in terms of high intensity streak suppression compared to oMAR, again with associated impacts on the particle range estimates. Conclusion We found no benefits of the water override compared to the rest, and tentatively reject hypothesis I. We however found improvements in the automatic algorithms, and thus support for hypothesis II, and found the MR‐based kerMAR to improve upon oMAR, supporting hypothesis III.
Collapse
Affiliation(s)
- Jonathan Scharff Nielsen
- Department of Health Technology, Technical University of Denmark, 2800 Kgs., Lyngby, Denmark.,Radiotherapy Research Unit, Department of Oncology, Gentofte and Herlev Hospital, University of Copenhagen, 2730, Herlev, Denmark
| | - Koen Van Leemput
- Department of Health Technology, Technical University of Denmark, 2800 Kgs., Lyngby, Denmark.,Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, 02114, USA
| | - Jens Morgenthaler Edmund
- Radiotherapy Research Unit, Department of Oncology, Gentofte and Herlev Hospital, University of Copenhagen, 2730, Herlev, Denmark.,Niels Bohr Institute, University of Copenhagen, 2100, Copenhagen, Denmark
| |
Collapse
|
14
|
Sillanpaa J, Lovelock M, Mueller B. The effects of the orthopedic metal artifact reduction (O-MAR) algorithm on contouring and dosimetry of head and neck radiotherapy patients. Med Dosim 2019; 45:92-96. [PMID: 31375297 DOI: 10.1016/j.meddos.2019.07.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2019] [Revised: 06/25/2019] [Accepted: 07/09/2019] [Indexed: 12/20/2022]
Abstract
Metallic objects, such as dental fillings, cause artifacts in computed tomography (CT) scans. We quantify the contouring and dosimetric effects of Orthopedic Metal Artifact Reduction (O-MAR), in head and neck radiotherapy. The ease of organ contouring was assessed by having a radiation oncologist identify the CT data set with or without O-MAR for each of 28 patients that was easier to contour. The effect on contouring was quantified further by having the physician recontour parotid glands, previously drawn by him on the O-MAR scans, on uncorrected scans, and calculating the Dice coefficent (a measure of overlap) for the contours. Radiotherapy plans originally generated on scans reconstructed with O-MAR were recalculated on scans without metal artifact correction. The study was done using the Analytical Anisotropic Algorithm (AAA) dose calculation algorithm. The 15 patients with a planning target volume (PTV) extending to the same slice as the artifacts were used for this part of the study. The normal tissue doses were not significantly affected. The PTV mean dose and V95 were not affected, but the cold spots became less severe in the O-MAR corrected plans, with the minimum point dose on average being 4.1% higher. In 79% of the cases, the radiation oncologist identified the O-MAR scan as easier to contour; in 11% he chose the uncorrected scan and in 11% the scans were judged to have equal quality. A total of nine parotid glands (on both scans-18 contours in total) in 5 patients were recontoured. The average Dice coefficient for parotids drawn with and without O-MAR was found to be 0.775 +/- 0.045. The O-MAR algorithm does not produce a significant dosimetric effect in head and neck plans when using the AAA dose calculation algorithm. It can therefore be used for improved contouring accuracy without updating the critical structure tolerance doses and target coverage expectations.
Collapse
Affiliation(s)
- Jussi Sillanpaa
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NJ 07748, USA.
| | - Michael Lovelock
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NJ 07748, USA
| | - Boris Mueller
- Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NJ 07748, USA
| |
Collapse
|
15
|
Niehues SM, Vahldiek JL, Tröltzsch D, Hamm B, Shnayien S. Impact of Single-Energy Metal Artifact Reduction on CT image quality in patients with dental hardware. Comput Biol Med 2018; 103:161-166. [DOI: 10.1016/j.compbiomed.2018.10.023] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2018] [Revised: 09/24/2018] [Accepted: 10/18/2018] [Indexed: 10/28/2022]
|
16
|
Sunwoo L, Park SW, Rhim JH, Kang Y, Chung YS, Son YJ, Kim SC. Metal Artifact Reduction for Orthopedic Implants: Brain CT Angiography in Patients with Intracranial Metallic Implants. J Korean Med Sci 2018; 33:e158. [PMID: 29780296 PMCID: PMC5955738 DOI: 10.3346/jkms.2018.33.e158] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2018] [Accepted: 03/26/2018] [Indexed: 11/20/2022] Open
Abstract
BACKGROUND The purpose of this study was to qualitatively and quantitatively evaluate the effects of a metal artifact reduction for orthopedic implants (O-MAR) for brain computed tomographic angiography (CTA) in patients with aneurysm clips and coils. METHODS The study included 36 consecutive patients with 47 intracranial metallic implants (42 aneurysm clips, 5 coils) who underwent brain CTA. The computed tomographic images with and without the O-MAR were independently reviewed both quantitatively and qualitatively by two reviewers. For quantitative analysis, image noises near the metallic implants of non-O-MAR and O-MAR images were compared. For qualitative analysis, image quality improvement and the presence of new streak artifacts were assessed. RESULTS Image noise was significantly reduced near metallic implants (P < 0.01). Improvement of implant-induced streak artifacts was observed in eight objects (17.0%). However, streak artifacts were aggravated in 11 objects (23.4%), and adjacent vessel depiction was worsened in eight objects (17.0%). In addition, new O-MAR-related streak artifacts were observed in 32 objects (68.1%). New streak artifacts were more prevalent in cases with overlapping metallic implants on the same axial plane than in those without (P = 0.018). Qualitative assessment revealed that the overall image quality was not significantly improved in O-MAR images. CONCLUSION In conclusion, the use of the O-MAR in patients with metallic implants significantly reduces image noise. However, the degree of the streak artifacts and surrounding vessel depiction were not significantly improved on O-MAR images.
Collapse
Affiliation(s)
- Leonard Sunwoo
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea
| | - Sun-Won Park
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea
- Department of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul, Korea
| | - Jung Hyo Rhim
- Department of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul, Korea
| | - Yeonah Kang
- Department of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul, Korea
| | - Young Seob Chung
- Department of Neurosurgery, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul, Korea
| | - Young-Je Son
- Department of Neurosurgery, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul, Korea
| | - Soo Chin Kim
- Department of Radiology, Seoul National University Hospital, Healthcare System Gangnam Center, Seoul, Korea
| |
Collapse
|
17
|
Metal Artifact Reduction for Orthopedic Implants (O-MAR): Usefulness in CT Evaluation of Reverse Total Shoulder Arthroplasty. AJR Am J Roentgenol 2017; 209:860-866. [PMID: 28796543 DOI: 10.2214/ajr.16.17684] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
OBJECTIVE The objective of this study is to evaluate the effect of the metal artifact reduction algorithm for orthopedic implants (O-MAR) on CT image quality for patients with reverse total shoulder arthroplasty (RTSA), with emphasis placed on the evaluation of bone in the vicinity of prostheses. MATERIALS AND METHODS Sixty-five patients who underwent CT scanning after RTSA were enrolled in the study. Two radiologists analyzed the images reconstructed with filtered back projection (FBP) with or without O-MAR processing. Images were evaluated to determine the degree of streaking artifacts, the confidence in depicting various structures around the prosthesis, and the presence of pseudolesions. The mean CT number and SD of the selected ROIs placed in the greater tuberosity, glenoid bone, and deltoid muscle were recorded. For measurements from the greater tuberosity and glenoid bone, the frequency with which the measurement met the typical CT number of bone was calculated. RESULTS O-MAR images showed less metal streak artifact and noise and provided better visualization of the axillary neurovascular bundle compared with FBP images, with a statistically significant difference (p < 0.001 for all). FBP images were found to be statistically significantly better than O-MAR images, offering better visualization of bone cortex, bone trabeculae, and the bone-prosthesis interface (p < 0.001 for all). Scapular pseudonotching was observed on 4.6% of FBP images and 36.9% of O-MAR images. The pseudocemented appearance was noted on 47.7% of O-MAR images but was not seen on FBP images. CONCLUSION The use of O-MAR improved CT image quality for patients with RTSA in the aspect of metal artifact reduction and soft-tissue profile. However, O-MAR tends to degrade depiction of the bone trabeculae and bone cortex and generate new artifacts, including a pseudocemented appearance and scapular pseudonotching.
Collapse
|
18
|
Davis AT, Palmer AL, Nisbet A. Can CT scan protocols used for radiotherapy treatment planning be adjusted to optimize image quality and patient dose? A systematic review. Br J Radiol 2017; 90:20160406. [PMID: 28452568 PMCID: PMC5603945 DOI: 10.1259/bjr.20160406] [Citation(s) in RCA: 46] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2016] [Revised: 03/16/2017] [Accepted: 04/24/2017] [Indexed: 01/27/2023] Open
Abstract
This article reviews publications related to the use of CT scans for radiotherapy treatment planning, specifically the impact of scan protocol changes on CT number and treatment planning dosimetry and on CT image quality. A search on PubMed and EMBASE and a subsequent review of references yielded 53 relevant articles. CT scan parameters significantly affect image quality. Some will also affect Hounsfield unit (HU) values, though this is not comprehensively reported on. Changes in tube kilovoltage and, on some scanners, field of view and reconstruction algorithms have been found to produce notable HU changes. The degree of HU change which can be tolerated without changing planning dose by >1% depends on the body region and size, planning algorithms, treatment beam energy and type of plan. A change in soft-tissue HU value has a greater impact than changes in HU for bone and air. The use of anthropomorphic phantoms is recommended when assessing HU changes. There is limited published work on CT scan protocol optimization in radiotherapy. Publications suggest that HU tolerances of ±20 HU for soft tissue and of ±50 HU for the lung and bone would restrict dose changes in the treatment plan to <1%. Literature related to the use of CT images in radiotherapy planning has been reviewed to establish the acceptable level of HU change and the impact on image quality of scan protocol adjustment. Conclusions have been presented and further work identified.
Collapse
Affiliation(s)
- Anne T Davis
- Department of Physics, Faculty of Engineering and Physical Science, University of Surrey, Guildford, UK
- Department of Medical Physics, Portsmouth Hospitals NHS Trust, Portsmouth, UK
| | - Antony L Palmer
- Department of Physics, Faculty of Engineering and Physical Science, University of Surrey, Guildford, UK
- Department of Medical Physics, Portsmouth Hospitals NHS Trust, Portsmouth, UK
| | - Andrew Nisbet
- Department of Physics, Faculty of Engineering and Physical Science, University of Surrey, Guildford, UK
- Department of Medical Physics, Royal Surrey County Hospital NHS Foundation Trust, Guildford, UK
| |
Collapse
|
19
|
Hansen CR, Christiansen RL, Lorenzen EL, Bertelsen AS, Asmussen JT, Gyldenkerne N, Eriksen JG, Johansen J, Brink C. Contouring and dose calculation in head and neck cancer radiotherapy after reduction of metal artifacts in CT images. Acta Oncol 2017; 56:874-878. [PMID: 28464749 DOI: 10.1080/0284186x.2017.1287427] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
BACKGROUND Delineation accuracy of the gross tumor volume (GTV) in radiotherapy planning for head and neck (H&N) cancer is affected by computed tomography (CT) artifacts from metal implants which obscure identification of tumor as well as organs at risk (OAR). This study investigates the impact of metal artifact reduction (MAR) in H&N patients in terms of delineation consistency and dose calculation precision in radiation treatment planning. MATERIAL AND METHODS Tumor and OAR delineations were evaluated in planning CT scans of eleven oropharynx patients with streaking artifacts in the tumor region preceding curative radiotherapy (RT). The GTV-tumor (GTV-T), GTV-node and parotid glands were contoured by four independent observers on standard CT images and MAR images. Dose calculation was evaluated on thirty H&N patients with dental implants near the treated volume. For each patient, the dose derived from the clinical treatment plan using the standard image set was compared with the recalculated dose on the MAR image dataset. RESULTS Reduction of metal artifacts resulted in larger volumes of all delineated structures compared to standard reconstruction. The GTV-T and the parotids were on average 22% (p < 0.06) and 7% larger (p = 0.005), respectively, in the MAR image plan compared to the standard image plan. Dice index showed reduced inter-observer variations after reduction of metal artifacts for all structures. The average surface distance between contours of different observers improved using the MAR images for GTV and parotids (p = 0.04 and p = 0.01). The median volume receiving a dose difference larger than ±3% was 2.3 cm3 (range 0-32 cm3). CONCLUSIONS Delineation of structures in the head and neck were affected by metal artifacts and volumes were generally larger and more consistent after reduction of metal artifacts, however, only small changes were observed in the dose calculations.
Collapse
Affiliation(s)
- Christian Rønn Hansen
- Laboratory of Radiation Physics, Odense University Hospital, Odense, Denmark
- Institute of Clinical Research, University of Southern Denmark, Odense, Denmark
| | | | | | | | - Jon Thor Asmussen
- Department of Radiology, Odense University Hospital, Odense, Denmark
| | | | - Jesper Grau Eriksen
- Institute of Clinical Research, University of Southern Denmark, Odense, Denmark
- Department of Oncology, Odense University Hospital, Odense, Denmark
| | - Jørgen Johansen
- Department of Oncology, Odense University Hospital, Odense, Denmark
| | - Carsten Brink
- Laboratory of Radiation Physics, Odense University Hospital, Odense, Denmark
- Institute of Clinical Research, University of Southern Denmark, Odense, Denmark
| |
Collapse
|
20
|
Giantsoudi D, De Man B, Verburg J, Trofimov A, Jin Y, Wang G, Gjesteby L, Paganetti H. Metal artifacts in computed tomography for radiation therapy planning: dosimetric effects and impact of metal artifact reduction. Phys Med Biol 2017; 62:R49-R80. [DOI: 10.1088/1361-6560/aa5293] [Citation(s) in RCA: 82] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
21
|
Das IJ, Cheng CW, Cao M, Johnstone PAS. Computed tomography imaging parameters for inhomogeneity correction in radiation treatment planning. J Med Phys 2016; 41:3-11. [PMID: 27051164 PMCID: PMC4795414 DOI: 10.4103/0971-6203.177277] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Modern treatment planning systems provide accurate dosimetry in heterogeneous media (such as a patient' body) with the help of tissue characterization based on computed tomography (CT) number. However, CT number depends on the type of scanner, tube voltage, field of view (FOV), reconstruction algorithm including artifact reduction and processing filters. The impact of these parameters on CT to electron density (ED) conversion had been subject of investigation for treatment planning in various clinical situations. This is usually performed with a tissue characterization phantom with various density plugs acquired with different tube voltages (kilovoltage peak), FOV reconstruction and different scanners to generate CT number to ED tables. This article provides an overview of inhomogeneity correction in the context of CT scanning and a new evaluation tool, difference volume dose-volume histogram (DVH), dV-DVH. It has been concluded that scanner and CT parameters are important for tissue characterizations, but changes in ED are minimal and only pronounced for higher density materials. For lungs, changes in CT number are minimal among scanners and CT parameters. Dosimetric differences for lung and prostate cases are usually insignificant (<2%) in three-dimensional conformal radiation therapy and < 5% for intensity-modulated radiation therapy (IMRT) with CT parameters. It could be concluded that CT number variability is dependent on acquisition parameters, but its dosimetric impact is pronounced only in high-density media and possibly in IMRT. In view of such small dosimetric changes in low-density medium, the acquisition of additional CT data for financially difficult clinics and countries may not be warranted.
Collapse
Affiliation(s)
- Indra J Das
- Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, IN 46202, USA
| | - Chee-Wai Cheng
- Department of Radiation Oncology, University Hospitals Case Medical Center, Cleveland, OH 44255, USA
| | - Minsong Cao
- Department of Radiation Oncology, University of California- Los Angeles School of Medicine, CA 90095, USA
| | - Peter A S Johnstone
- Department of Radiation Oncology, Moffitt Cancer Center, Tampa, FL 33612, USA
| |
Collapse
|