Tongkum S, Suwanpradit P, Vidhyarkorn S, Siripongsakun S, Oonsiri S, Rakvongthai Y, Khamwan K. Determination of radiation dose and low-dose protocol for digital chest tomosynthesis using radiophotoluminescent (RPL) glass dosimeters. Phys Med 2020; 73:13-21. [PMID: 32279046 DOI: 10.1016/j.ejmp.2020.03.024] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2019] [Revised: 02/07/2020] [Accepted: 03/29/2020] [Indexed: 12/24/2022] Open
Abstract
PURPOSE This study aimed to determine a low-dose protocol for digital chest tomosynthesis (DTS). METHODS Five simulated nodules with a CT number of approximately 100 HU with size diameter of 3, 5, 8, 10, and 12 mm were inserted into an anthropomorphic chest phantom (N1 Lungman model), and then scanned by DTS system (Definium 8000) with varying tube voltage, copper filter thickness, and dose ratio. Three radiophotoluminescent (RPL) glass dosimeters, type GD-352 M with a dimension of 1.5 × 12 mm, were used to measure the entrance surface air kerma (ESAK) in each protocol. The effective dose (ED) was calculated using the recorded total dose-area-product (DAP). The signal-to-noise ratio (SNR) was determined for qualitative image quality evaluation. The image criteria and nodule detection capability were scored by two experienced radiologists. The selected low-dose protocol was further applied in a clinical study with 30 pulmonary nodule follow-up patients. RESULTS The average ESAK obtained from the standard default protocol was 1.68 ± 0.15 mGy, while an ESAK of 0.47 ± 0.02 mGy was found for a low-dose protocol. The EDs for the default and low-dose protocols were 313.98 ± 0.72 µSv and 100.55 ± 0.28 µSv, respectively. There were small non-significant differences in the image criteria and nodule detection scoring between the low-dose and default protocols interpreted by two radiologists. The effective dose of 98.87 ± 0.08 µSv was obtained in clinical study after applying the low-dose protocol. CONCLUSIONS The low-dose protocol obtained in this study can substantially reduce radiation dose while preserving an acceptable image quality compared to the standard protocol.
Collapse
Affiliation(s)
- Sarawut Tongkum
- Medical Physics Graduate Program, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok 10330, Thailand; Department of Diagnostic and Interventional Radiology, Chulabhorn Hospital, Bangkok 10210, Thailand
| | - Petcharleeya Suwanpradit
- Division of Diagnostic Radiology, Department of Radiology, King Chulalongkorn Memorial Hospital, The Thai Red Cross Society, Bangkok 10330, Thailand
| | - Sirachat Vidhyarkorn
- Department of Diagnostic and Interventional Radiology, Chulabhorn Hospital, Bangkok 10210, Thailand
| | - Surachate Siripongsakun
- Sonographer School, Faculty of Heath Science Technology, HRH Princess Chulabhorn College of Medical Science, Chulabhorn Royal Academy, Bangkok, Thailand
| | - Sornjarod Oonsiri
- Division of Radiation Oncology, Department of Radiology, King Chulalongkorn Memorial Hospital, The Thai Red Cross Society, Bangkok 10330, Thailand
| | - Yothin Rakvongthai
- Medical Physics Graduate Program, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok 10330, Thailand; Division of Nuclear Medicine, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok 10330, Thailand; Chulalongkorn University Biomedical Imaging Group, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok 10330, Thailand
| | - Kitiwat Khamwan
- Medical Physics Graduate Program, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok 10330, Thailand; Division of Nuclear Medicine, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok 10330, Thailand; Chulalongkorn University Biomedical Imaging Group, Department of Radiology, Faculty of Medicine, Chulalongkorn University, Bangkok 10330, Thailand.
| |
Collapse
|
2
|
Jadidi M, Båth M, Nyrén S. Dependency of image quality on acquisition protocol and image processing in chest tomosynthesis-a visual grading study based on clinical data. Br J Radiol 2018; 91:20170683. [PMID: 29565673 DOI: 10.1259/bjr.20170683] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
OBJECTIVE To compare the quality of images obtained with two different protocols with different acquisition time and the influence from image post processing in a chest digital tomosynthesis (DTS) system. METHODS 20 patients with suspected lung cancer were imaged with a chest X-ray equipment with tomosynthesis option. Two examination protocols with different acquisition times (6.3 and 12 s) were performed on each patient. Both protocols were presented with two different image post-processing (standard DTS processing and more advanced processing optimised for chest radiography). Thus, 4 series from each patient, altogether 80 series, were presented anonymously and in a random order. Five observers rated the quality of the reconstructed section images according to predefined quality criteria in three different classes. Visual grading characteristics (VGC) was used to analyse the data and the area under the VGC curve (AUCVGC) was used as figure-of-merit. The 12 s protocol and the standard DTS processing were used as references in the analyses. RESULTS The protocol with 6.3 s acquisition time had a statistically significant advantage over the vendor-recommended protocol with 12 s acquisition time for the classes of criteria, Demarcation (AUCVGC = 0.56, p = 0.009) and Disturbance (AUCVGC = 0.58, p < 0.001). A similar value of AUCVGC was found also for the class Structure (definition of bone structures in the spine) (0.56) but it could not be statistically separated from 0.5 (p = 0.21). For the image processing, the VGC analysis showed a small but statistically significant advantage for the standard DTS processing over the more advanced processing for the classes of criteria Demarcation (AUCVGC = 0.45, p = 0.017) and Disturbance (AUCVGC = 0.43, p = 0.005). A similar value of AUCVGC was found also for the class Structure (0.46), but it could not be statistically separated from 0.5 (p = 0.31). CONCLUSION The study indicates that the protocol with 6.3 s acquisition time yields slightly better image quality than the vender-recommended protocol with acquisition time 12 s for several anatomical structures. Furthermore, the standard gradation processing (the vendor-recommended post-processing for DTS), yields to some extent advantage over the gradation processing/multiobjective frequency processing/flexible noise control processing in terms of image quality for all classes of criteria. Advances in knowledge: The study proves that the image quality may be strongly affected by the selection of DTS protocol and that the vendor-recommended protocol may not always be the optimal choice.
Collapse
Affiliation(s)
- Masoud Jadidi
- 1 Departments of Clinical Science, Intervention and Technology, Karolinska Institutet , Stockholm , Sweden
| | - Magnus Båth
- 2 Department of Radiation Physics, Sahlgrenska Academy at University of Gothenburg , Gothenburg , Sweden.,3 Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital , Gothenburg , Sweden
| | - Sven Nyrén
- 4 Molecular medicine and surgery, Karolinska intitutet , Stockholm , Sweden.,5 Department of Thoracic radiology, Karolinska University Hospital , Stockholm , Sweden
| |
Collapse
|
3
|
Båth M, Hansson J. VGC ANALYZER: A SOFTWARE FOR STATISTICAL ANALYSIS OF FULLY CROSSED MULTIPLE-READER MULTIPLE-CASE VISUAL GRADING CHARACTERISTICS STUDIES. RADIATION PROTECTION DOSIMETRY 2016; 169:46-53. [PMID: 26769908 DOI: 10.1093/rpd/ncv542] [Citation(s) in RCA: 52] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Visual grading characteristics (VGC) analysis is a non-parametric rank-invariant method for analysis of visual grading data. In VGC analysis, image quality ratings for two different conditions are compared by producing a VGC curve, similar to how the ratings for normal and abnormal cases in receiver operating characteristic (ROC) analysis are used to create an ROC curve. The use of established ROC software for the analysis of VGC data has therefore previously been proposed. However, the ROC analysis is based on the assumption of independence between normal and abnormal cases. In VGC analysis, this independence cannot always be assumed, e.g. if the ratings are based on the same patients imaged under both conditions. A dedicated software intended for analysis of VGC studies, which takes possible dependencies between ratings into account in the statistical analysis of a VGC study, has therefore been developed. The software-VGC Analyzer-determines the area under the VGC curve and its uncertainty using non-parametric resampling techniques. This article gives an introduction to VGC Analyzer, describes the types of analyses that can be performed and instructs the user about the input and output data.
Collapse
Affiliation(s)
- Magnus Båth
- Department of Radiation Physics, Institute of Clinical Sciences, The Sahlgrenska Academy at University of Gothenburg, SE-413 45 Gothenburg, Sweden Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, SE-413 45 Gothenburg, Sweden
| | - Jonny Hansson
- Department of Radiation Physics, Institute of Clinical Sciences, The Sahlgrenska Academy at University of Gothenburg, SE-413 45 Gothenburg, Sweden Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, SE-413 45 Gothenburg, Sweden
| |
Collapse
|
4
|
Arvidsson J, Söderman C, Allansdotter Johnsson Å, Bernhardt P, Starck G, Kahl F, Båth M. IMAGE FUSION OF RECONSTRUCTED DIGITAL TOMOSYNTHESIS VOLUMES FROM A FRONTAL AND A LATERAL ACQUISITION. RADIATION PROTECTION DOSIMETRY 2016; 169:410-415. [PMID: 26683464 DOI: 10.1093/rpd/ncv507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Digital tomosynthesis (DTS) has been used in chest imaging as a low radiation dose alternative to computed tomography (CT). Traditional DTS shows limitations in the spatial resolution in the out-of-plane dimension. As a first indication of whether a dual-plane dual-view (DPDV) DTS data acquisition can yield a fair resolution in all three spatial dimensions, a manual registration between a frontal and a lateral image volume was performed. An anthropomorphic chest phantom was scanned frontally and laterally using a linear DTS acquisition, at 120 kVp. The reconstructed image volumes were resampled and manually co-registered. Expert radiologist delineations of the mediastinal soft tissues enabled calculation of similarity metrics in regard to delineations in a reference CT volume. The fused volume produced the highest total overlap, implying that the fused volume was a more isotropic 3D representation of the examined object than the traditional chest DTS volumes.
Collapse
Affiliation(s)
- Jonathan Arvidsson
- Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, SE-413 45 Gothenburg, Sweden Department of Radiation Physics, Institute of Clinical Sciences, The Sahlgrenska Academy at University of Gothenburg, SE-413 45 Gothenburg, Sweden
| | - Christina Söderman
- Department of Radiation Physics, Institute of Clinical Sciences, The Sahlgrenska Academy at University of Gothenburg, SE-413 45 Gothenburg, Sweden
| | - Åse Allansdotter Johnsson
- Department of Radiology, Institute of Clinical Sciences, Sahlgrenska University Hospital, SE-413 45 Gothenburg, Sweden Department of Radiology, Sahlgrenska University Hospital, SE-413 45 Gothenburg, Sweden
| | - Peter Bernhardt
- Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, SE-413 45 Gothenburg, Sweden Department of Radiation Physics, Institute of Clinical Sciences, The Sahlgrenska Academy at University of Gothenburg, SE-413 45 Gothenburg, Sweden
| | - Göran Starck
- Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, SE-413 45 Gothenburg, Sweden Department of Radiation Physics, Institute of Clinical Sciences, The Sahlgrenska Academy at University of Gothenburg, SE-413 45 Gothenburg, Sweden
| | - Fredrik Kahl
- Department of Signals and Systems, Digital Image Systems and Image Analysis, Chalmers University of Technology, SE-412 96 Gothenburg, Sweden
| | - Magnus Båth
- Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, SE-413 45 Gothenburg, Sweden Department of Radiation Physics, Institute of Clinical Sciences, The Sahlgrenska Academy at University of Gothenburg, SE-413 45 Gothenburg, Sweden
| |
Collapse
|