1
|
Shujaat S, Vasconcelos KDF, Kesztyüs A, Fontenele RC, Oliveira-Santos N, Nagy K, Shaheen E, Jacobs R. Optimization of orofacial cleft imaging protocols using device-specific low-dose cone-beam computed tomography. J Oral Rehabil 2024. [PMID: 38873694 DOI: 10.1111/joor.13745] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 05/02/2024] [Accepted: 05/08/2024] [Indexed: 06/15/2024]
Abstract
OBJECTIVE The aim of this study was to present optimized device-specific low-dose cone-beam computed tomography (CBCT) protocols with sufficient image quality for pre-surgical diagnostics and three-dimensional (3D) modelling of cleft defects. METHODS Six paediatric skulls were acquired, and an artificial bony cleft was created. A high-resolution CBCT scan acted as a reference standard (Accuitomo 170, Morita, Kyoto, Japan) for comparing eight low-dose protocols of Newtom VGi-evo (QR Verona, Cefla, Verona, Italy), which included Eco and Regular protocols with different field of views (FOVs). Delineation of lamina dura, cementoenamel junction (CEJ), trabecular bone and bony bridge were assessed. A 3D model of the defect was also evaluated. RESULT The dose area product of low-dose protocols ranged from 31 to 254 mGy*cm2. Despite the dose difference of up to eight times between applied protocols, trabecular bone and CEJ exhibited appropriate image quality in all scans. However, Regular small FOV protocols (5 × 5 and 8 × 5 cm2), for both lamina dura and bony bridge, demonstrated a significant improvement in image quality compared to Eco FOV counterparts. Based on 3D defect analysis, no significant difference existed between low-dose protocols and the reference standard. CONCLUSION The findings highlight the possibility of achieving a considerable reduction (up to eight times) in the radiation dose using low-dose CBCT protocols while maintaining sufficient image quality for assessing anatomical structures and 3D modelling in cleft cases.
Collapse
Affiliation(s)
- Sohaib Shujaat
- OMFS IMPATH Research Group, Department of Imaging & Pathology, Faculty of Medicine, KU Leuven & Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
- King Abdullah International Medical Research Center, Department of Maxillofacial Surgery and Diagnostic Sciences, College of Dentistry, King Saud bin Abdulaziz University for Health Sciences, Ministry of National Guard Health Affairs, Riyadh, Saudi Arabia
| | - Karla de Faria Vasconcelos
- OMFS IMPATH Research Group, Department of Imaging & Pathology, Faculty of Medicine, KU Leuven & Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Artúr Kesztyüs
- Center for Facial Reconstruction, 1st Department of Paediatrics, Semmelweis University, Budapest, Hungary
| | - Rocharles Cavalcante Fontenele
- OMFS IMPATH Research Group, Department of Imaging & Pathology, Faculty of Medicine, KU Leuven & Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Nicolly Oliveira-Santos
- OMFS IMPATH Research Group, Department of Imaging & Pathology, Faculty of Medicine, KU Leuven & Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Krisztian Nagy
- Center for Facial Reconstruction, 1st Department of Paediatrics, Semmelweis University, Budapest, Hungary
| | - Eman Shaheen
- OMFS IMPATH Research Group, Department of Imaging & Pathology, Faculty of Medicine, KU Leuven & Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Reinhilde Jacobs
- OMFS IMPATH Research Group, Department of Imaging & Pathology, Faculty of Medicine, KU Leuven & Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
- Section of Oral Diagnostics and Surgery, Department of Dental Medicine, Division of Oral Diagnostics and Rehabilitation, Karolinska Institutet, Huddinge, Sweden
| |
Collapse
|
2
|
Merken K, Monnens J, Marshall N, Johan N, Brasil DM, Santaella GM, Politis C, Jacobs R, Bosmans H. Development and validation of a 3D anthropomorphic phantom for dental CBCT imaging research. Med Phys 2023; 50:6714-6736. [PMID: 37602774 DOI: 10.1002/mp.16661] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 07/17/2023] [Accepted: 07/17/2023] [Indexed: 08/22/2023] Open
Abstract
BACKGROUND Optimization of dental cone beam computed tomography (CBCT) imaging is still in a preliminary stage and should be addressed using task-based methods. Dedicated models containing relevant clinical tasks for image quality studies have yet to be developed. PURPOSE To present a methodology to develop and validate a virtual adult anthropomorphic voxel phantom for use in task-based image quality optimization studies in dental CBCT imaging research, focusing on root fracture (RF) detection tasks in the presence of metal artefacts. METHODS The phantom was developed from a CBCT scan with an isotropic voxel size of 0.2 mm, from which the main dental structures, mandible and maxilla were segmented. The missing large anatomical structures, including the spine, skull and remaining soft tissues, were segmented from a lower resolution full skull scan. Anatomical abnormalities were absent in the areas of interest. Fine detailed dental structures, that could not be segmented due to the limited resolution and noise in the clinical data, were modelled using a-priori anatomical knowledge. Model resolution of the teeth was therefore increased to 0.05 mm. Models of RFs as well as dental restorations to create the artefacts, were developed, and could be inserted in the phantom in any desired configuration. Simulated CBCT images of the models were generated using a newly developed multi-resolution simulation framework that incorporated the geometry, beam quality, noise and spatial resolution characteristics of a real dental CBCT scanner. Ray-tracing and Monte Carlo techniques were used to create the projection images, which were reconstructed using the classical FDK algorithm. Validation of the models was assessed by measurements of different tooth lengths, the pulp volume and the mandible, and comparison with reference values. Additionally, the simulated images were used in a reader study in which two oral radiologists had to score the realism level of the model's normal anatomy, as well as the modelled RFs and restorations. RESULTS A model of an adult head, as well as models of RFs and different types of dental restorations were created. Anatomical measurements were consistent with ranges reported in literature. For the tooth length measurements, the deviations from the mean reference values were less than 20%. In 77% of all the measurements, the deviations were within 10.1%. The pulp volumes, and mandible measurements were within one standard deviation of the reference values. Regarding the normal anatomy, both readers considered the realism level of the dental structures to be good. Background structures received a lower realism score due to the lack of detailed enough trabecular bone structure, which was expected but not the focus of this study. All modelled RFs were scored at least adequate by at least one of the readers, both in appearance and position. The realism level of the modelled restorations was considered to be good. CONCLUSIONS A methodology was proposed to develop and validate an anthropomorphic voxel phantom for image quality optimization studies in dental CBCT imaging, with a main focus on RF detection tasks. The methodology can be extended further to create more models representative of the clinical population.
Collapse
Affiliation(s)
- Karen Merken
- Department of Imaging and Pathology, Division of Medical Physics & Quality Assessment, KU Leuven, Leuven, Belgium
| | - Janne Monnens
- Department of Imaging and Pathology, Division of Medical Physics & Quality Assessment, KU Leuven, Leuven, Belgium
| | - Nicholas Marshall
- Department of Imaging and Pathology, Division of Medical Physics & Quality Assessment, KU Leuven, Leuven, Belgium
| | - Nuyts Johan
- Department of Imaging and Pathology, Division of Nuclear Medicine & Molecular Imaging, KU Leuven, Leuven, Belgium
| | - Danieli Moura Brasil
- Department of Diagnosis and Oral Health, School of Dentistry, University of Louisville, Louisville, Kentucky, USA
| | - Gustavo Machado Santaella
- Department of Diagnosis and Oral Health, School of Dentistry, University of Louisville, Louisville, Kentucky, USA
| | - Constantinus Politis
- Department of Imaging and Pathology, Division of Oral and Maxillofacial Surgery, KU Leuven, Leuven, Belgium
| | - Reinhilde Jacobs
- Department of Imaging and Pathology, Division of Oral and Maxillofacial Surgery, KU Leuven, Leuven, Belgium
- Department of Dental Medicine, Karolinska Institutet, Huddinge, Sweden
| | - Hilde Bosmans
- Department of Imaging and Pathology, Division of Medical Physics & Quality Assessment, KU Leuven, Leuven, Belgium
| |
Collapse
|
3
|
Pálvölgyi L, Kesztyűs A, Shujaat S, Jacobs R, Nagy K. Creation of Dimicleft radiological cleft phantom skulls using reversed virtual planning technique. Dentomaxillofac Radiol 2023; 52:20230121. [PMID: 37395648 PMCID: PMC10552124 DOI: 10.1259/dmfr.20230121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 05/12/2023] [Accepted: 05/17/2023] [Indexed: 07/04/2023] Open
Abstract
OBJECTIVES The aim of this technical report was to develop customized pediatric phantoms for cone-beam computed tomography (CBCT)-related research in cleft patients. METHODS Six human pediatric skulls (age: 5-10 years) were recruited. A cone-beam computed tomography (CBCT) scan was taken for each skull, followed by virtual modeling through the process of segmentation. An artificial cleft was designed and printed to be applied onto the skull for the creation of an artificial cleft. The skulls were covered with non-radiopaque tape and immersed in melted Mix-D soft tissue equivalent material. The resulting phantoms covered with Mix-D were assessed radiologically by two expert radiologists. These phantoms were referred to as Dimicleft pediatric skull phantoms. RESULTS Dimicleft phantoms were able to appropriately mimic in vivo circumstances. No gaps existed between Mix-D and bony tissue. Virtual planning allowed the optimal designing of an artificial cleft onto the phantom. The artificially created cleft was suitable to determine the size, location, and extent of the cleft. CONCLUSIONS Dimicleft phantoms could act as a viable alternative to other commercially available options for assessing image quality and optimizing CBCT protocols in cleft patients for diagnostics and three-dimensional treatment planning.
Collapse
Affiliation(s)
- Laura Pálvölgyi
- Center for Facial Reconstruction, 1st Department of Paediatrics, Semmelweis University, Budapest, Hungary
| | - Artúr Kesztyűs
- Center for Facial Reconstruction, 1st Department of Paediatrics, Semmelweis University, Budapest, Hungary
| | | | | | - Krisztián Nagy
- Center for Facial Reconstruction, 1st Department of Paediatrics, Semmelweis University, Budapest, Hungary
| |
Collapse
|
4
|
Brasil DM, Merken K, Binst J, Bosmans H, Haiter-Neto F, Jacobs R. Monitoring cone-beam CT radiation dose levels in a University Hospital. Dentomaxillofac Radiol 2023; 52:20220213. [PMID: 36802857 PMCID: PMC9944015 DOI: 10.1259/dmfr.20220213] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Revised: 12/24/2022] [Accepted: 01/10/2023] [Indexed: 02/23/2023] Open
Abstract
OBJECTIVE To present patient dose levels for different CBCT scanners, acquired by a dose monitoring tool in a University Hospital, as a function of field of view (FOV), operation mode, and patient age. METHODS An integrated dose monitoring tool was used to collect radiation exposure data [type of CBCT unit, dose-area product (DAP), FOV size, and operation mode] and patient demographic information (age, referral department) performed on a 3D Accuitomo 170 and a Newtom VGI EVO unit. Effective dose conversion factors were calculated and implemented into the dose monitoring system. For each CBCT unit, the frequency of examinations, clinical indications, and effective dose levels were obtained for different age and FOV groups, and operation modes. RESULTS A total of 5163 CBCT examinations were analyzed. Surgical planning and follow-up were the most frequent clinical indications. For the standard operation mode, effective doses ranged from 35.1 to 300 µSv and 9.26-117 µSv using 3D Accuitomo 170 and Newtom VGI EVO, respectively. In general, effective doses decreased with increasing age and FOV size reduction. CONCLUSIONS Effective dose levels varied notably between systems and operation modes.Operation mode selection and FOV size were indication-oriented, with larger FOV sizes election serving surgical planning and follow-up. Seeing the influence of FOV size on effective dose levels, manufacturers could be advised to move toward patient-specific collimation and dynamic FOV selection. Systematically monitoring patient doses could be recommended for steering future CBCT optimization.
Collapse
Affiliation(s)
| | - Karen Merken
- Department of Imaging and Pathology, KU Leuven, Division of Medical Physics & Quality Assessment, Leuven, Belgium
| | - Joke Binst
- Department of Radiology, UZ Leuven, Leuven, Belgium
| | | | - Francisco Haiter-Neto
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil
| | | |
Collapse
|
5
|
Quantification of DNA Double Strand Breaks and Oxidation Response in Children and Adults Undergoing Dental CBCT Scan. Sci Rep 2020; 10:2113. [PMID: 32034200 PMCID: PMC7005754 DOI: 10.1038/s41598-020-58746-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2019] [Accepted: 01/03/2020] [Indexed: 01/22/2023] Open
Abstract
Assessing the possible biological effects of exposure to low doses of ionizing radiation (IR) is one of the prime challenges in radiation protection, especially in medical imaging. Today, radiobiological data on cone beam CT (CBCT) related biological effects are scarce. In children and adults, the induction of DNA double strand breaks (DSBs) in buccal mucosa cells and 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxo-dG) and antioxidant capacity in saliva samples after CBCT examination were examined. No DNA DSBs induction was observed in children nor adults. In children only, an increase in 8-oxo-dG levels was observed 30 minutes after CBCT. At the same time an increase in antioxidant capacity was observed in children, whereas a decrease was observed in adults. Our data indicate that children and adults react differently to IR doses associated with CBCT. Fully understanding these differences could lead to an optimal use of CBCT in different age categories as well as improved radiation protection guidelines.
Collapse
|
6
|
Colceriu-Şimon IM, Băciuţ M, Ştiufiuc RI, Aghiorghiesei A, Ţărmure V, Lenghel M, Hedeşiu M, Băciuţ G. Clinical indications and radiation doses of cone beam computed tomography in orthodontics. Med Pharm Rep 2019; 92:346-351. [PMID: 31750433 PMCID: PMC6853038 DOI: 10.15386/mpr-1434] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2019] [Accepted: 08/21/2019] [Indexed: 11/23/2022] Open
Abstract
Cone beam computed tomography can be used in pediatric population when a tridimensional analysis of dental and maxillofacial bone structures is required. Even though CBCT is considered a low dose radiological examination, ionizing radiation is a known human carcinogenic factor. Furthermore, biological effects are more important in young patients because of their higher radiosensitivity. Orthodontic treatment is typically initiated at young ages and the most common radiographs at this age are dental. This makes it important to quantify the effects of diagnostic radiographs, in particular of CBCT, due to the fact that the radiation doses are higher compared to conventional radiological methods. So far, the carcinogenic response after low dose radiation exposure is not fully understood in the scientific literature. The aim of our review was to emphasize the main indications of CBCT in orthodontics and to evaluate the radiation doses and potential risks of CBCT irradiation of pediatric patients.
Collapse
Affiliation(s)
- Ioana Maria Colceriu-Şimon
- Department of Orthodontics and Dentofacial Orthopedics, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Mihaela Băciuţ
- Department of Oral Rehabilitation, Maxillofacial Surgery and Implantology, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Rareş Ionuţ Ştiufiuc
- Department of Pharmaceutical Physics-Biophysics, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Alexandra Aghiorghiesei
- Department of Prosthetic Dentistry and Dental Materials, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Viorica Ţărmure
- Department of Orthodontics and Dentofacial Orthopedics, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Manuela Lenghel
- Department of Radiology, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Mihaela Hedeşiu
- Department of Oral Radiology, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Grigore Băciuţ
- Department of Cranio-Maxillofacial Surgery, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| |
Collapse
|
7
|
Stratis A, Zhang G, Jacobs R, Bogaerts R, Bosmans H. The growing concern of radiation dose in paediatric dental and maxillofacial CBCT: an easy guide for daily practice. Eur Radiol 2019; 29:7009-7018. [DOI: 10.1007/s00330-019-06287-5] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2018] [Revised: 04/21/2019] [Accepted: 05/24/2019] [Indexed: 11/24/2022]
|
8
|
Halve the dose while maintaining image quality in paediatric Cone Beam CT. Sci Rep 2019; 9:5521. [PMID: 30940872 PMCID: PMC6445070 DOI: 10.1038/s41598-019-41949-w] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2018] [Accepted: 03/20/2019] [Indexed: 11/08/2022] Open
Abstract
Cone beam CT (CBCT) for dentomaxillofacial paediatric assessment has been widely used despite the uncertainties of the risks of the low-dose radiation exposures. The aim of this work was to investigate the clinical performance of different CBCT acquisition protocols towards the optimization of paediatric exposures. Custom-made anthropomorphic phantoms were scanned using a CBCT unit in six protocols. CT slices were blinded, randomized and presented to three observers, who scored the image quality using a 4-point scale along with their level of confidence. Sharpness level was also measured using a test object containing an air/PMMA e,dge. The effective dose was calculated by means of a customized Monte Carlo (MC) framework using previously validated paediatric voxels models. The results have shown that the protocols set with smaller voxel size (180 µm), even when decreasing exposure parameters (kVp and mAs), showed high image quality scores and increased sharpness. The MC analysis showed a gradual decrease in effective dose when exposures parameters were reduced, with an emphasis on an average reduction of 45% for the protocol that combined 70 kVp, 16 mAs and 180 µm voxel size. In contrast, both "ultra-low dose" protocols that combined a larger voxel size (400 µm) with lower mAs (7.4 mAs) demonstrated the lowest scores with high levels of confidence unsuitable for an anatomical approach. In conclusion, a significant decrease in the effective dose can be achieved while maintaining the image quality required for paediatric CBCT.
Collapse
|