1
|
C P R, Krishnan M, Raveendran V, Chaudhari L, Laskar S. Assessment of pencil beam scanning proton therapy beam delivery accuracy through machine learning and log file analysis. Phys Med 2024; 127:104854. [PMID: 39488127 DOI: 10.1016/j.ejmp.2024.104854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2024] [Revised: 09/10/2024] [Accepted: 10/28/2024] [Indexed: 11/04/2024] Open
Abstract
PURPOSE Comprehensive Quality Assurance (QA) protocols are necessary for complex beam delivery systems like Pencil Beam Scanning (PBS) proton therapy. This study focuses on automating the evaluation of beam delivery accuracy using irradiation log files and machine learning (ML) models. METHODS Irradiation log files of 935 clinical treatment fields and routine QA beams were analysed to evaluate spot parameters and Monitor Unit (MU) accuracy. ML models predicted spot size along the X, Y, major, and minor axes. In-house scripts automated log file analysis and spot size predictions. Predicted spot sizes were compared with expected baselines, and the accuracy of spot position, symmetry, and MU for each spot in the beam was evaluated. RESULTS More than 99.5 % of spot positions were accurate within a 1 mm. The mean and Standard Deviation (SD) of X positional error were -0.021 mm (SD: 0.181 mm), and for Y positional error, they were -0.002 mm (SD: 0.132 mm). ML models accurately predicted spot sizes, with over 95 % of spots demonstrating size variations within 10 % of the baseline. The Root Mean Squared Error (RMSE) of X and Y spot size differences were 0.15 mm and 0.16 mm, respectively. Spot symmetry was within 10 %, and MU accuracy showed 95 % of spots with MU per spot variation less than 2 %. CONCLUSION This method can validate the vendor's beam delivery safety interlock system and serve as a quick alternative to patient-specific QA in adaptive treatment, where time is limited, as well as for routine QA spot parameter evaluations.
Collapse
Affiliation(s)
- Ranjith C P
- Department of Medical Physics, Centre for Interdisciplinary Research, D. Y. Patil Education Society (Deemed to be University), Kolhapur, Maharashtra, India; Department of Radiation Oncology, Advanced Centre for Treatment Research and Education in Cancer, Homi Bhabha National Institute, Mumbai, Maharashtra, India
| | - Mayakannan Krishnan
- Department of Medical Physics, Centre for Interdisciplinary Research, D. Y. Patil Education Society (Deemed to be University), Kolhapur, Maharashtra, India.
| | - Vysakh Raveendran
- Department of Radiation Oncology, Advanced Centre for Treatment Research and Education in Cancer, Homi Bhabha National Institute, Mumbai, Maharashtra, India
| | - Lalit Chaudhari
- Department of Radiation Oncology, Advanced Centre for Treatment Research and Education in Cancer, Homi Bhabha National Institute, Mumbai, Maharashtra, India
| | - Siddhartha Laskar
- Department of Radiation Oncology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, Maharashtra, India
| |
Collapse
|
2
|
Chang C, Bohannon D, Tian Z, Wang Y, Mcdonald MW, Yu DS, Liu T, Zhou J, Yang X. A retrospective study on the investigation of potential dosimetric benefits of online adaptive proton therapy for head and neck cancer. J Appl Clin Med Phys 2024; 25:e14308. [PMID: 38368614 PMCID: PMC11087169 DOI: 10.1002/acm2.14308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 10/28/2023] [Accepted: 02/06/2024] [Indexed: 02/20/2024] Open
Abstract
PURPOSE Proton therapy is sensitive to anatomical changes, often occurring in head-and-neck (HN) cancer patients. Although multiple studies have proposed online adaptive proton therapy (APT), there is still a concern in the radiotherapy community about the necessity of online APT. We have performed a retrospective study to investigate the potential dosimetric benefits of online APT for HN patients relative to the current offline APT. METHODS Our retrospective study has a patient cohort of 10 cases. To mimic online APT, we re-evaluated the dose of the in-use treatment plan on patients' actual treatment anatomy captured by cone-beam CT (CBCT) for each fraction and performed a templated-based automatic replanning if needed, assuming that these were performed online before treatment delivery. Cumulative dose of the simulated online APT course was calculated and compared with that of the actual offline APT course and the designed plan dose of the initial treatment plan (referred to as nominal plan). The ProKnow scoring system was employed and adapted for our study to quantify the actual quality of both courses against our planning goals. RESULTS The average score of the nominal plans over the 10 cases is 41.0, while those of the actual offline APT course and our simulated online course is 25.8 and 37.5, respectively. Compared to the offline APT course, our online course improved dose quality for all cases, with the score improvement ranging from 0.4 to 26.9 and an average improvement of 11.7. CONCLUSION The results of our retrospective study have demonstrated that online APT can better address anatomical changes for HN cancer patients than the current offline replanning practice. The advanced artificial intelligence based automatic replanning technology presents a promising avenue for extending potential benefits of online APT.
Collapse
Affiliation(s)
- Chih‐Wei Chang
- Department of Radiation Oncology and Winship Cancer InstituteEmory UniversityAtlantaGeorgiaUSA
| | - Duncan Bohannon
- Department of Radiation Oncology and Winship Cancer InstituteEmory UniversityAtlantaGeorgiaUSA
| | - Zhen Tian
- Department of Radiation and Cellular OncologyUniversity of ChicagoChicagoIllinoisUSA
| | - Yinan Wang
- Department of Radiation Oncology and Winship Cancer InstituteEmory UniversityAtlantaGeorgiaUSA
| | - Mark W. Mcdonald
- Department of Radiation Oncology and Winship Cancer InstituteEmory UniversityAtlantaGeorgiaUSA
| | - David S. Yu
- Department of Radiation Oncology and Winship Cancer InstituteEmory UniversityAtlantaGeorgiaUSA
| | - Tian Liu
- Department of Radiation OncologyMount Sinai Medical CenterNew YorkNew YorkUSA
| | - Jun Zhou
- Department of Radiation Oncology and Winship Cancer InstituteEmory UniversityAtlantaGeorgiaUSA
| | - Xiaofeng Yang
- Department of Radiation Oncology and Winship Cancer InstituteEmory UniversityAtlantaGeorgiaUSA
| |
Collapse
|
3
|
Rao X, Liu H, Zhang Y, Xie Y, Wang G, Zhang S, Wu G, Wang Y, Zhou R. The relationship of body mass index to setup errors, dosimetric parameters and incidence of radiation pneumonitis in non-small cell lung cancer patients undergoing intensity-modulated radiation therapy: a single-center observational study. Int J Radiat Biol 2024; 100:248-255. [PMID: 37747796 DOI: 10.1080/09553002.2023.2261549] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Accepted: 09/14/2023] [Indexed: 09/27/2023]
Abstract
BACKGROUND The relationship among body mass index (BMI), setup error and radiation pneumonitis is not clearly illustrated. OBJECTIVE The present study aimed to investigate the role of BMI in non-small cell lung cancer (NSCLC) patients' radiation treatment, focusing on its relationship with setup error of patient positioning, the dosimetric parameters of intensity-modulated radiation therapy (IMRT) and the incidence of radiation pneumonitis. METHODS This prospective observational study included 523 cases of NSCLC patients during 2020-2022. Patients were divided into different groups by different BMI. The setup error was obtained by cone beam CT (CBCT) at three positions, lateral (LAT), longitudinal (LNG) and vertical (VRT). IMRT dosimetric parameters of V5, V20, and mean dose were collected. RESULTS Patients with BMI ≥28 kg/m2 showed significantly higher absolute values of LAT, LNG and VRT, higher V5, V20, mean dose, as well as higher total incidence of radiation pneumonitis and grade III radiation pneumonitis compared with patients with BMI <24 kg/m2 or 24-28 kg/m2. Spearman's analysis demonstrated that the absolute values of LAT, LNG and VRT were positively correlated with BMI, and positive correlation existed among BMI, dosimetric parameters and setup errors. ROC curves showed that LAT in setup errors and V5 in dosimetric parameters had the best diagnostic value for prediction of radiation pneumonitis. Only BMI, LAT, V5 and V20 were the independent risk factors for radiation pneumonitis. CONCLUSIONS Setup error caused by higher BMI might be associated with the dosimetric parameters, as well as the incidence of radiation pneumonitis in NSCLC patients.
Collapse
Affiliation(s)
- Xinrui Rao
- Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, PR China
- Institute of Radiation Oncology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, PR China
| | - Hongyuan Liu
- Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, PR China
- Institute of Radiation Oncology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, PR China
| | - Yuewen Zhang
- Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, PR China
- Institute of Radiation Oncology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, PR China
| | - Yaqiong Xie
- Oncology Department, Jianli People's Hospital, Jingzhou, PR China
| | - Geng Wang
- Department of Gastrointestinal Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, PR China
| | - Sheng Zhang
- Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, PR China
- Institute of Radiation Oncology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, PR China
| | - Gang Wu
- Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, PR China
- Institute of Radiation Oncology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, PR China
| | - Ye Wang
- Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, PR China
- Institute of Radiation Oncology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, PR China
| | - Rui Zhou
- Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, PR China
- Institute of Radiation Oncology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, PR China
| |
Collapse
|
4
|
Tan HQ, Lew KS, Koh CWY, Wibawa A, Yeap PL, Master Z, Lee JCL, Beltran CJ, Park SY, Furutani KM. Implementing dispersion measurement as part of scanning proton therapy commissioning and quality assurance. Phys Med Biol 2023; 68:225001. [PMID: 37857314 DOI: 10.1088/1361-6560/ad0536] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2023] [Accepted: 10/19/2023] [Indexed: 10/21/2023]
Abstract
Introduction. Dispersion in an accelerator quantifies the deviation of the proton trajectory when there is a momentum deviation. We present for the first time a safe method of measuring dispersion in the clinic, using a scintillator detector and the momentum deviations within a spill. This is an important accelerator quantity as we found that this is the reason behind the large dose fluctuation in our absolute dosimetry measurement.Methods. Dispersions are measured for nine energies in a Hitachi ProBeat system at three locations (isocenter and at two profile monitors) and at two gantry angles (0 and 90 degrees) by first measuring the spot position and momentum drift within a spill. The spot position drift is measured by the XRV-4000 at the isocenter, and by the two profile monitors located at 0.57 and 2.27 m from the isocenter. The momentum drift is calculated from the intra-spill range drift which is measured using the Ranger accessory. The dispersion at isocenter and its gradient are calculated using the weighted least square regression on the measured dispersions at the three locations. A constraint is formulated on the dispersion and its gradient to ensure minimal intra-spill spot position deviation around the isocenter.Results. The measured intra-spill range and spot positional drift at isocenter are less than0.25mmand0.7mmrespectively. The momentum spread calculated from the range drift are less than 0.08%. The dispersion at the isocenter ranged from0.50to4.30mand the zero-crossing happens upstream of isocenter for all energies. 2 of the 9 energies (168.0 and 187.5 MeV) violated the constraint and has an intra-spill spot positional deviation greater than1.0within5cmfrom the isocenter.Conclusion. This measurement is recommended as part of commissioning and annual quality assurance for accelerator monitoring and to ensure intra-spill spot deviations remain low.
Collapse
Affiliation(s)
- Hong Qi Tan
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore
- Oncology Academic Clinical Programme, Duke-NUS Medical School, Singapore
| | - Kah Seng Lew
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore
| | | | - Andrew Wibawa
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore
| | - Ping Lin Yeap
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore
| | - Zubin Master
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore
| | | | - Chris J Beltran
- Department of Radiation Oncology, Mayo Clinic Florida, Jacksonville, FL, United States of America
| | - Sung Yong Park
- Division of Radiation Oncology, National Cancer Centre Singapore, Singapore
- Oncology Academic Clinical Programme, Duke-NUS Medical School, Singapore
| | - Keith M Furutani
- Department of Radiation Oncology, Mayo Clinic Florida, Jacksonville, FL, United States of America
| |
Collapse
|