1
|
Benavides E, Krecioch JR, Connolly RT, Allareddy T, Buchanan A, Spelic D, O'Brien KK, Keels MA, Mascarenhas AK, Duong ML, Aerne-Bowe MJ, Ziegler KM, Lipman RD. Optimizing radiation safety in dentistry: Clinical recommendations and regulatory considerations. J Am Dent Assoc 2024; 155:280-293.e4. [PMID: 38300176 DOI: 10.1016/j.adaj.2023.12.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 11/20/2023] [Accepted: 12/12/2023] [Indexed: 02/02/2024]
Abstract
BACKGROUND The value of dental radiographs to oral health care decision making must be balanced with radiation safety to minimize patient exposure and occupational risk of oral health care providers. This review summarizes recommendations and regulatory guidance regarding dental radiography and cone-beam computed tomography. An expert panel presents recommendations on radiation safety, appropriate imaging practices, and reducing radiation exposure. TYPES OF STUDIES REVIEWED A systematic search run in Ovid MEDLINE, Embase, and Cochrane Database of Systematic Reviews identified relevant topical systematic reviews, organizational guidelines, and regulatory reviews published in the peer-reviewed literature since 2010. A supplemental search of the gray literature (eg, technical reports, standards, and regulations) identified topical nonindexed publications. Inclusion criteria required relevance to primary oral health care (ie, general or pediatric dentistry). RESULTS A total of 95 articles, guidance documents, and regulations met the inclusion criteria. Resources were characterized as applicable to all modalities, operator and occupational protection, dose reduction and optimization, and quality assurance and control. PRACTICAL IMPLICATIONS Understanding factors affecting imaging safety and applying fundamental principles of radiation protection consistent with federal, state, and local requirements are essential for limiting patient ionizing radiation exposure, in conjunction with implementing optimal imaging procedures to support prudent use of dental radiographs and cone-beam computed tomographic imaging. The regulatory guidance and best practice recommendations summarized in this article should be followed by dentists and other oral health care providers.
Collapse
|
2
|
Ríos-Osorio N, Quijano-Guauque S, Briñez-Rodríguez S, Velasco-Flechas G, Muñoz-Solís A, Chávez C, Fernandez-Grisales R. Cone-beam computed tomography in endodontics: from the specific technical considerations of acquisition parameters and interpretation to advanced clinical applications. Restor Dent Endod 2024; 49:e1. [PMID: 38449497 PMCID: PMC10912545 DOI: 10.5395/rde.2024.49.e1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 09/26/2023] [Accepted: 10/13/2023] [Indexed: 03/08/2024] Open
Abstract
The implementation of imaging methods that enable sensitive and specific observation of anatomical structures has been a constant in the evolution of endodontic therapy. Cone-beam computed tomography (CBCT) enables 3-dimensional (3D) spatial anatomical navigation in the 3 volumetric planes (sagittal, coronal and axial) which translates into great accuracy for the identification of endodontic pathologies/conditions. CBCT interpretation consists of 2 main components: (i) the generation of specific tasks of the image and (ii) the subsequent interpretation report. A systematic and reproducible method to review CBCT scans can improve the accuracy of the interpretation process, translating into greater precision in terms of diagnosis and planning of endodontic clinical procedures. MEDLINE (PubMed), Web of Science, Google Scholar, Embase and Scopus were searched from inception to March 2023. This narrative review addresses the theoretical concepts, elements of interpretation and applications of the CBCT scan in endodontics. In addition, the contents and rationale for reporting 3D endodontic imaging are discussed.
Collapse
Affiliation(s)
- Néstor Ríos-Osorio
- Research Department COC-CICO, Institución Universitaria Colegios de Colombia UNICOC, Bogotá, Colombia
| | - Sara Quijano-Guauque
- Research Department COC-CICO, Institución Universitaria Colegios de Colombia UNICOC, Bogotá, Colombia
| | - Sandra Briñez-Rodríguez
- Research Department COC-CICO, Institución Universitaria Colegios de Colombia UNICOC, Bogotá, Colombia
| | - Gustavo Velasco-Flechas
- Research Department COC-CICO, Institución Universitaria Colegios de Colombia UNICOC, Bogotá, Colombia
| | | | - Carlos Chávez
- Postgraduate Endodontics Department, IMED, Guadalajara, México
| | | |
Collapse
|
3
|
Pauwels R, Pittayapat P, Sinpitaksakul P, Panmekiate S. Scatter-to-primary ratio in dentomaxillofacial cone-beam CT: effect of field of view and beam energy. Dentomaxillofac Radiol 2021; 50:20200597. [PMID: 33882256 DOI: 10.1259/dmfr.20200597] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE The aim of this study was to evaluate the effect of field of view (FOV) and beam energy on the scatter-to-primary ratio (SPR) in dental cone-beam CT (CBCT). METHODS An anthropomorphic phantom representing an adult male (ATOM Max 711-HN, Norfolk, VA, USA) was scanned using the 3D Accuitomo 170 CBCT (J. Morita, Kyoto, Japan) using 11 FOVs. During each scan, half of the X-ray beam was blocked. Each scan was performed at three exposure settings with varying beam energy and equal radiation dose: 90 kV 5 mA, 77 kV 7.5 mA and 69 kV 10 mA. The SPR was estimated by measuring the grey values in the blocked and non-blocked regions of the RAW data. The effect of FOV on SPR was evaluated using Dunn's multiple comparison test, and the effect of the exposure settings was compared using a Wilcoxon signed rank test. RESULTS Larger FOVs showed increased scatter. FOVs with a shorter isocenter-detector distance showed a particularly high SPR. Most intercomparisons between FOVs were statistically significant. The largest difference was found between 17 × 12 cm and 6 × 6 cm (lower jaw), with the former showing a 4.9-fold higher SPR. The effect of beam energy was relatively small and varied between FOV sizes and positions. CONCLUSION While the choice of FOV size and position is determined by the diagnostic region of interest, the image quality deterioration for large FOVs due to scatter provides another incentive to limit the FOV size as much as possible.
Collapse
Affiliation(s)
- Ruben Pauwels
- Aarhus Institute of Advanced Studies, Aarhus University, Aarhus, Denmark.,Department of Radiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Pisha Pittayapat
- Department of Radiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Phonkit Sinpitaksakul
- Department of Radiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Soontra Panmekiate
- Department of Radiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| |
Collapse
|
4
|
Maret D, Vergnes JN, Peters OA, Peters C, Nasr K, Monsarrat P. Recent Advances in Cone-beam CT in Oral Medicine. Curr Med Imaging 2021; 16:553-564. [PMID: 32484089 DOI: 10.2174/1573405615666190114152003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2018] [Revised: 12/09/2018] [Accepted: 12/19/2018] [Indexed: 11/22/2022]
Abstract
BACKGROUND The cone-beam computed tomography (CBCT) technology has continuously evolved since its appearance in oral medicine in the early 2000s. OBJECTIVES To present recent advances in CBCT in oral medicine: i) selection of recent and consensual evidence-based sources, ii) structured summary of the information based on an iterative framework and iii) compliance with ethical, public health and patient-centered concerns. MAIN FINDINGS We will focus on technological advances, such as sensors and reconstruction algorithms used to improve the constant quality of the image and dosimetry. CBCT examination is now performed in almost all disciplines of oral medicine: currently, the main clinical disciplines that use CBCT acquisitions are endodontics and oral surgery, with clearly defined indications. Periodontology and ear, nose and throat medicine are more recent fields of application. For a given application and indication, the smallest possible field of view must be used. One of the major challenges in contemporary healthcare is ensuring that technological developments do not take precedence over admitted standards of care. The entire volume should be reviewed in full, with a systematic approach. All findings are noted in the patient's record and explained to the patient, including incidental findings. This presupposes the person reviewing the images is sufficiently trained to interpret such images, inform the patient and organize the clinical pathway, with referrals to other medical or oral medicine specialties as needed. CONCLUSION A close collaboration between dentists, medical physicists, radiologists, radiographers and engineers is critical for all aspects of CBCT technology.
Collapse
Affiliation(s)
- Delphine Maret
- Oral Rehabilitation Department, Dental Faculty, Paul Sabatier University, Toulouse University Hospital (CHU de Toulouse), Toulouse, France.,AMIS Laboratory - Laboratoire Anthropologie Moléculaire et Imagerie de Synthèse, Université de Toulouse, UMR 5288 CNRS, UPS, Toulouse, France
| | - Jean-Noel Vergnes
- Epidemiology and Public Health Department, Dental Faculty, Paul Sabatier University, Toulouse University Hospital (CHU de Toulouse), Toulouse, France.,Division of Oral Health and Society, Faculty of Dentistry, McGill University, Montreal, Quebec, Canada
| | - Ove A Peters
- Department of Endodontics, Arthur A. Dugoni School of Dentistry, University of the Pacific, San Francisco, California, United States.,School of Dentistry, University of Queensland, Brisbane, Queensland, Australia
| | - Christine Peters
- Department of Endodontics, Arthur A. Dugoni School of Dentistry, University of the Pacific, San Francisco, California, United States
| | - Karim Nasr
- Oral Rehabilitation Department, Dental Faculty, Paul Sabatier University, Toulouse University Hospital (CHU de Toulouse), Toulouse, France
| | - Paul Monsarrat
- Oral Rehabilitation Department, Dental Faculty, Paul Sabatier University, Toulouse University Hospital (CHU de Toulouse), Toulouse, France.,STROMALab, Université de Toulouse, CNRS ERL 5311, EFS, ENVT, Inserm U1031, UPS, Toulouse, France
| |
Collapse
|
5
|
Effects of Exposure Parameters and Voxel Size for Cone-Beam Computed Tomography on the Image Matching Accuracy with an Optical Dental Scan Image: An In Vitro Study. BIOMED RESEARCH INTERNATIONAL 2021; 2021:6971828. [PMID: 34222482 PMCID: PMC8213486 DOI: 10.1155/2021/6971828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/18/2021] [Accepted: 06/02/2021] [Indexed: 11/17/2022]
Abstract
This study is aimed at assessing the effects of exposure parameters and voxel size for cone-beam computed tomography (CBCT) on the image matching accuracy with an optical dental scan image. CBCT and optical scan images of a dry human mandible were obtained. Different CBCT settings were used: tube voltage, 60, 80, and 100 kVp; tube current, 6 and 8 mA; and voxel size, 100, 200, and 300 μm. Image matching between the CBCT and optical scan images was performed using implant planning software by dental professionals (n = 18). The image matching accuracy in each combination of CBCT settings was evaluated by assessing the linear discrepancy between the three-dimensionally reconstructed radiological image and the registered optical scan image using an image analysis software program. The Kruskal-Wallis test and a post hoc Mann–Whitney U test with Bonferroni correction were used to compare the accuracy of image registration between the groups (α = 0.05). Overall, the image matching accuracy was not significantly different between tube voltage and current settings; however, significantly higher image registration errors were found at the combination of 100 kVp tube voltage/8 mA tube current (F = 8.44, P < 0.001). Changes in voxel sizes did not significantly interfere with the image registration results. No interaction was found among voltage, current, and voxel size in terms of image registration accuracy (F = 2.022, P = 0.091). Different exposure parameter settings in tube voltage and tube current did not significantly influence the image matching accuracy between CBCT and optical dental scan images; however, a high radiation dose could be inappropriate. The image matching accuracy was not significantly affected by changing the voxel sizes of CBCT.
Collapse
|
6
|
Siiskonen T, Gallagher A, Ciraj Bjelac O, Novak L, Sans Merce M, Farah J, Dabin J, Malchair F, Knežević Ž, Kortesniemi M. A European perspective on dental cone beam computed tomography systems with a focus on optimisation utilising diagnostic reference levels. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2021; 41:442-451. [PMID: 33461178 DOI: 10.1088/1361-6498/abdd05] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2020] [Accepted: 01/18/2021] [Indexed: 06/12/2023]
Abstract
Cone beam computed tomography (CBCT) has been available since the late 1990s for use in dentistry. European legislation requires optimisation of protection and the use of diagnostic reference levels (DRLs) as well as regular quality control (QC) of the imaging devices, which is well outlined in existing international recommendations. Nevertheless, the level of application is not known. Earlier studies have indicated that few European countries have established DRLs and that patient doses (exposure parameters) have not been properly optimised. The EURADOS Working Group 12-Dosimetry in Medical Imaging undertook a survey to identify existing practices in Member States. Questionnaires were developed to identify equipment types, clinical procedures performed, and exposure settings used. The surveys were circulated to 22 countries resulting in 28 responses from 13 countries. Variations were identified in the exposure factors and in the doses delivered to patients for similar clinical indicators. Results confirm that patient doses are still not properly optimised and DRLs are largely not established. There is a need to promote the importance of performing QC testing of dental CBCT equipment and to further optimise patient exposure by establishment and use of DRLs as a part of a continuous optimisation process.
Collapse
Affiliation(s)
- Teemu Siiskonen
- Radiation and Nuclear Safety Authority (STUK), P.O. Box 14, FI-00881 Helsinki, Finland
| | | | - Olivera Ciraj Bjelac
- University of Belgrade, Vinca Institute of Nuclear Sciences (VINCA), Belgrade, Serbia
| | - Leos Novak
- National Radiation Protection Institute (NRPI), Prague, Czech Republic
| | - Marta Sans Merce
- Hôpitaux Universitaires de Genève, Genève, Switzerland
- Switzerland and Centre Hospitalier Universitaire Vaudois (CHUV), Lausanne, Switzerland
| | - Jad Farah
- Hôpitaux universitaires Paris-Sud (APHP), Paris Sud University Hospitals, Paris, France
| | - Jérémie Dabin
- Belgian Nuclear Research Centre (SCK-CEN), Boeretang 200, BE-2400 Mol, Belgium
| | - Françoise Malchair
- CAATS, 119 Grande Rue, 92310 Sevres, France
- ZEPHYRA, 13 rue Forgeur, 4000 Liege, Belgium
- Centre Hospitalier Universitaire de Liège (CHULg), Sart-Tilman, 4000 Liège, Belgium
| | - Željka Knežević
- Ruđer Bošković Institute (RBI), Bijenicka 54, Zagreb, Croatia
| | - Mika Kortesniemi
- HUS Medical Imaging Center, Helsinki University and Helsinki University Hospital, Haartmaninkatu 4, 00290 Helsinki, Finland
| |
Collapse
|
7
|
Al-Okshi A, Horner K, Rohlin M. A meta-review of effective doses in dental and maxillofacial cone beam CT using the ROBIS tool. Br J Radiol 2021; 94:20210042. [PMID: 33989050 DOI: 10.1259/bjr.20210042] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
OBJECTIVES To apply the ROBIS tool for assessment of risk of bias (RoB) in systematic reviews (SRs) in a meta-review on effective doses (EDs) in dental and maxillofacial cone beam CT. METHODS Three electronic databases and reference lists of included SRs were searched. Eligible SRs were classified as having low, high or unclear RoB. Findings of SRs were synthesised and data from primary studies combined to relate ED to field of view (FOV) and operating potential (kV). RESULTS Seven SRs were included: three displayed low RoB, three high and one had unclear RoB. Only one SR related ED to image quality. Deficiencies in reporting of eligibility criteria, study selection and synthesis of results in SRs were identified. FOV height had a significant relationship with ED, explaining 27.2% of its variability. Median ED for three FOV categories differed significantly. Operating potential had a weak relationship with ED, with no significant difference in median ED between three operating potential groups. CONCLUSION The ROBIS tool should have a role for meta-reviews of different aspects of radiology. The disappointing results for RoB might be remedied by developing standards to improve the quality of reporting of primary dosimetry studies and of SRs. Future dosimetry studies should always relate ED to image quality or diagnostic accuracy. ADVANCES IN KNOWLEDGE This meta-review is the first to implement ROBIS for SRs of ED and identified that trustworthiness of some SRs is questionable. The percentage change in average ED per cm increase in FOV height could be calculated, emphasizing the importance of FOV as a determinant of ED in CBCT.
Collapse
Affiliation(s)
- Ayman Al-Okshi
- Department of Oral Medicine and Radiology, Faculty of Dentistry, Sebha University, Sebha, Libya.,Faculty of Odontology, Malmö University, Malmö, Sweden
| | - Keith Horner
- Division of Dentistry, School of Medical Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester Academic Health Science Centre, Manchester, UK
| | | |
Collapse
|
8
|
Gaêta-Araujo H, Leite AF, Vasconcelos KDF, Jacobs R. Two decades of research on CBCT imaging in DMFR - an appraisal of scientific evidence. Dentomaxillofac Radiol 2021; 50:20200367. [PMID: 33555198 DOI: 10.1259/dmfr.20200367] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
OBJECTIVE This article aims to appraise how scientific evidence related to CBCT has changed over the years, based on levels of evidence and diagnostic efficacy. METHODS A general search strategy was used in different databases (Pubmed, Embase, and Web of Science) to identify systematic reviews (SRs) on CBCT until November of 2020. The SRs included were divided according to different specialties of dentistry. A critical review of the articles was made, describing the level of evidence and efficacy. RESULTS In total, 75 articles were selected. There was an increase in the number of SRs on CBCT from 2014 onwards, as 83% of the SRs on this topic were published after 2013, and 72% between 2016 and to date. Twenty SRs (27%) performed meta-analysis. Only 28% of the SRs provided a detailed description of CBCT protocols. According to SR evidence, almost all specialties of dentistry have advanced concomitantly with the introduction of CBCT. The majority of SRs were related to clinical applications (level 2 of efficacy), followed by technical parameters (level 1 of efficacy). Only some CBCT models were mentioned in the SRs selected. CONCLUSION Over the course of 20 years, SRs related to CBCT applications for a broad range of dental specialties have been published, with the vast majority of studies at levels 1 and 2 of diagnostic efficacy. Not all CBCT models available on the market have been scientifically validated. At all times, one should remain cautious as such not to simply extrapolate in vitro results to the clinical setting. Also, considering the wide variety of CBCT devices and protocols, reported results should not be overstated or generalized, as outcomes often refer to specific CBCT devices and protocols.
Collapse
Affiliation(s)
- Hugo Gaêta-Araujo
- OMFS IMPATH Research Group, Department of Imaging & Pathology, Faculty of Medicine, University of Leuven and Oral & Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.,Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Av. Limeira, 901, 13414-903, Piracicaba, Sao Paulo, Brazil
| | - André Ferreira Leite
- OMFS IMPATH Research Group, Department of Imaging & Pathology, Faculty of Medicine, University of Leuven and Oral & Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.,Department of Dentistry, Faculty of Health Sciences, University of Brasilia, Brasilia, Brazil
| | - Karla de Faria Vasconcelos
- OMFS IMPATH Research Group, Department of Imaging & Pathology, Faculty of Medicine, University of Leuven and Oral & Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Reinhilde Jacobs
- OMFS IMPATH Research Group, Department of Imaging & Pathology, Faculty of Medicine, University of Leuven and Oral & Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.,Department of Dental Medicine, Karolinska Institute, Stockholm, Sweden
| |
Collapse
|
9
|
Abstract
Aims To investigate the awareness and practice of 2D and 3D diagnostic imaging, including respective equipment, specifications, number of images acquired, indications for CBCT scans, preference between 2D and 3D imaging, and the confidence in acquiring and interpreting radiographic images among dentists in Hong Kong.Materials and methods A citywide survey was performed with an online questionnaire that was sent via the local dental association to registered dentists in Hong Kong. The anonymous survey focused on: their dental background; number, type and age of their intra-oral, panoramic devices; CBCT indications, field-of-view and consideration of low-dose protocols; and their confidence in taking and interpreting these images.Results From the feedback collected, 65% of dentists used digital intra-oral systems. Around 70% of respondents who perform CBCTs utilised low-dose protocols to reduce radiation dose. Age and years of practising dentistry were significant influencing factors in determining dentists' utilisation of low-dose protocols for CBCT devices. Male dentists and dentists with higher qualifications generally reported being more confident in taking and interpreting CBCT images. Dentists who were older and had more years of practising dentistry were generally more confident in interpreting CBCT images.Conclusion Only half of the dentists feel confident in taking and interpreting CBCT images, and there seems to be a limited knowledge of radiation dose-related risks. Therefore, continuous professional education should specifically focus on the potential of digital imaging and training in CBCT modalities, radiation dose protection and image interpretation.
Collapse
|
10
|
Wang MF, Xie X, Li G, Zhang Z. Relationship between CNR and visibility of anatomical structures of cone-beam computed tomography images under different exposure parameters. Dentomaxillofac Radiol 2020; 49:20190336. [PMID: 32045279 PMCID: PMC7333469 DOI: 10.1259/dmfr.20190336] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2019] [Revised: 02/01/2020] [Accepted: 02/05/2020] [Indexed: 12/26/2022] Open
Abstract
OBJECTIVES The purpose of this study was to investigate the image quality of cone beam CT (CBCT) under different exposure parameters and the relationship between contrast-to-noise and visibility of eight anatomical structures. METHODS CBCT images for the evaluation of subjective image quality were acquired on an anthropopathic phantom containing a human skeleton embedded in soft tissue equivalent materials using 25 exposure protocols. Visibility of eight anatomical structures was evaluated by five independent observers. Using the SEDENTEXCT IQ Image Quality phantom, the contrast-to-noise ratio (CNR) was calculated by ImageJ software. RESULTS A reduction on the visibility of anatomical structures was seen under lower exposure parameters. However, for 84% of the protocols, visibility of anatomical structures remained acceptable even under some lower parameter settings. As CNR increased, the visibility of anatomical structures also increased correspondingly. A change point could be found in the CNR interval 29.42-36.51 after which the visibility of anatomical structures no longer increases with the increase of CNR. CONCLUSIONS Although CNR decrease under a lower exposure parameter, the image quality often remained acceptable at exposure levels below the manufacture's recommended settings. It is possible to standardize subjective image quality by physical factors. Currently, it is not possible to predetermine a change point CNR value due to different CBCT machine and variation of diagnostic tasks.
Collapse
Affiliation(s)
- Miss Fei Wang
- Department of oral and maxillofacial radiology, Stomatological Hospital, Peking University, Beijing, China
| | - Xiaoyan Xie
- Department of oral and maxillofacial radiology, Stomatological Hospital, Peking University, Beijing, China
| | - Gang Li
- Department of oral and maxillofacial radiology, Stomatological Hospital, Peking University, Beijing, China
| | - Zuyan Zhang
- Department of oral and maxillofacial radiology, Stomatological Hospital, Peking University, Beijing, China
| |
Collapse
|
11
|
Gaêta-Araujo H, Alzoubi T, Vasconcelos KDF, Orhan K, Pauwels R, Casselman JW, Jacobs R. Cone beam computed tomography in dentomaxillofacial radiology: a two-decade overview. Dentomaxillofac Radiol 2020; 49:20200145. [PMID: 32501720 DOI: 10.1259/dmfr.20200145] [Citation(s) in RCA: 54] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
OBJECTIVES The aim of this study was to evaluate and summarise features of currently and formerly available cone beam CT (CBCT) devices from 1996 to 2019. Additionally, a recommendation for standardised reporting of CBCT characteristics was provided. METHODS AND MATERIALS Information about the features of all available CBCT devices was obtained from the manufacturers' available data. Moreover, site visits to newly developed CBCT machines' manufacturers were performed in order to obtain relevant information. RESULTS A total of 279 CBCT models from 47 manufacturers located in 12 countries (Brazil, China, Denmark, Finland, France, Germany, Italy, Japan, Republic of Korea, Slovakia, Thailand, and USA) could be listed. Overall, wide variations in CBCT features and technical specifications were identified. CONCLUSIONS CBCT in dentomaxillofacial radiology is a generic term applicable to a broad range of CBCT machines and features. Experimental outcomes and literature statements regarding radiation doses, imaging performance and diagnostic applicability of dental CBCT cannot be simply transferred from one CBCT model to another considering a wide variation in technical characteristics and clinical diagnostic performance. The information tabulated in the present study will be later provided on the International Association of DentoMaxilloFacial Radiology website (www.iadmfr.one).
Collapse
Affiliation(s)
- Hugo Gaêta-Araujo
- OMFS IMPATH Research Group, Department of Imaging & Pathology, Faculty of Medicine, University of Leuven and Oral & Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.,Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, Sao Paulo, Brazil
| | - Tamara Alzoubi
- OMFS IMPATH Research Group, Department of Imaging & Pathology, Faculty of Medicine, University of Leuven and Oral & Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Karla de Faria Vasconcelos
- OMFS IMPATH Research Group, Department of Imaging & Pathology, Faculty of Medicine, University of Leuven and Oral & Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Kaan Orhan
- OMFS IMPATH Research Group, Department of Imaging & Pathology, Faculty of Medicine, University of Leuven and Oral & Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.,Department of DentoMaxillofacial Radiology, Ankara University, Faculty of Dentistry, Ankara, Turkey
| | - Ruben Pauwels
- Medical Physics & Quality Assessment Department of Imaging & Pathology, Faculty of Medicine, Catholic University of Leuven, Leuven, Belgium.,Aarhus Institute of Advanced Studies, Aarhus University, Aarhus, Denmark
| | | | - Reinhilde Jacobs
- OMFS IMPATH Research Group, Department of Imaging & Pathology, Faculty of Medicine, University of Leuven and Oral & Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.,Department of Dental Medicine, Karolinska Institutet, Huddinge, Sweden
| |
Collapse
|
12
|
Park HN, Min CK, Kim KA, Koh KJ. Optimization of exposure parameters and relationship between subjective and technical image quality in cone-beam computed tomography. Imaging Sci Dent 2019; 49:139-151. [PMID: 31281791 PMCID: PMC6597377 DOI: 10.5624/isd.2019.49.2.139] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2019] [Revised: 04/10/2019] [Accepted: 04/16/2019] [Indexed: 11/18/2022] Open
Abstract
Purpose This study was performed to investigate the effect of exposure parameters on image quality obtained using a cone-beam computed tomography (CBCT) scanner and the relationship between physical factors and clinical image quality depending on the diagnostic task. Materials and Methods CBCT images of a SedentexCT IQ phantom and a real skull phantom were obtained under different combinations of tube voltage and tube current (Alphard 3030 CBCT scanner, 78–90 kVp and 2–8 mA). The images obtained using a SedentexCT IQ phantom were analyzed technically, and the physical factors of image noise, contrast resolution, spatial resolution, and metal artifacts were measured. The images obtained using a real skull phantom were evaluated for each diagnostic task by 6 oral and maxillofacial radiologists, and each setting was classified as acceptable or unacceptable based on those evaluations. A statistical analysis of the relationships of exposure parameters and physical factors with observer scores was conducted. Results For periapical diagnosis and implant planning, the tube current of the acceptable images was significantly higher than that of the unacceptable images. Image noise, the contrast-to-noise ratio (CNR), the line pair chart on the Z axis, and modulation transfer function (MTF) values showed statistically significant differences between the acceptable and unacceptable image groups. The cut-off values obtained using receiver operating characteristic curves for CNR and MTF 10 were useful for determining acceptability. Conclusion Tube current had a major influence on clinical image quality. CNR and MTF 10 were useful physical factors that showed significantly associations with clinical image quality.
Collapse
Affiliation(s)
- Ha-Na Park
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Chonbuk National University, Jeonju, Korea
| | - Chang-Ki Min
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Chonbuk National University, Jeonju, Korea
| | - Kyoung-A Kim
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Chonbuk National University, Jeonju, Korea
| | - Kwang-Joon Koh
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Chonbuk National University, Jeonju, Korea
| |
Collapse
|
13
|
Hoff MN, Zamora D, Spiekerman C, Aps JK, Bollen AM, Herring SW, Katz F. Can cephalometric parameters be measured reproducibly using reduced-dose cone-beam computed tomography? J World Fed Orthod 2019. [DOI: 10.1016/j.ejwf.2019.02.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
14
|
El Sahili N, David-Tchouda S, Thoret S, Nasseh I, Berberi A, Fortin T. Effect of Milliamperage Reduction on Pre-surgical Implant Planning Using Cone Beam Computed Tomography by Surgeons of Varying Experience. J Maxillofac Oral Surg 2018; 17:520-530. [PMID: 30344396 PMCID: PMC6181865 DOI: 10.1007/s12663-017-1075-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2017] [Accepted: 12/14/2017] [Indexed: 10/18/2022] Open
Abstract
BACKGROUND Differences in CBCT units and the lack of standardization result in exposure to radiation doses beyond what is required for diagnostic purposes, especially when planning the surgical placement of dental implants. AIM To assess the influence of low- and high-dose milliamperage settings on CBCT images for objective and subjective implant planning among senior specialists (5 years of experience) and juniors (fresh graduates). MATERIALS AND METHODS Two dry skulls (4 hemi-maxillary segments of the maxilla and 4 hemi-maxillary segments of the mandible) were scanned under low (2 mA) and high (6.3 mA) dosage settings using the Carestream CS 9300 machine. Cross-sectional slices of both image qualities were evaluated by the 5 seniors and the 5 juniors for subjective image utility for implant planning and for objective linear bone measurements. RESULTS There were no significant differences in bone measurements taken on high- or low-dose images by all seniors and by the majority of juniors (p > 0.05). In qualitative image assessments, there was independence between assessment and image quality for almost all observers. For planning posterior mandibular implant placement, increased dosage improved concordance and kappa values between low- and high-dose images for senior observers (from K = 0.287 at low dose to K = 0.718 at high does) but not for juniors (K = 0.661 and K = 0.509 for low and high dose, respectively). CONCLUSION Reduction in milliamperage did not affect diagnostic image quality for objective bone measurements and produced sufficient concordance for qualitative assessment. Judicious optimization of milliamperage settings based on individual diagnostic requirements can result in significant dose reduction without compromising diagnostic decision-making.
Collapse
Affiliation(s)
- N. El Sahili
- School of Dentistry, Lebanese University, Beirut, Lebanon
| | - S. David-Tchouda
- Medico-economic Evaluation Unit, University Hospital of Grenoble, France/ThEMAS TIMC, UMR CNRS 5525, Grenoble Joseph Fourier University, Grenoble, France
| | - S. Thoret
- Investigation Clinical Center of Grenoble, INSERM, Grenoble, France
| | - I. Nasseh
- Department of Oral and Maxillofacial Surgery, School of Dentistry, Lebanese University, Beirut, Lebanon
| | - A. Berberi
- Department of Oral and MaxilloFaciale Surgery, School of Dentistry, Lebanese University, Beirut, Lebanon
| | - T. Fortin
- Department of Oral Surgery, Dental University of Lyon, University Claude Bernard, Lyon 1, France. UJF-Grenoble 1/CNRS/TIMC-IMAG UMR 5525, 38041 Grenoble, France
| |
Collapse
|
15
|
Alawaji Y, MacDonald DS, Giannelis G, Ford NL. Optimization of cone beam computed tomography image quality in implant dentistry. Clin Exp Dent Res 2018; 4:268-278. [PMID: 30603109 PMCID: PMC6305941 DOI: 10.1002/cre2.141] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2018] [Revised: 10/02/2018] [Accepted: 10/03/2018] [Indexed: 11/10/2022] Open
Abstract
This study was conducted to optimize the cone beam computed tomography image quality in implant dentistry using both clinical and quantitative image quality evaluation with measurement of the radiation dose. A natural bone human skull phantom and an image quality phantom were used to evaluate the images produced after changing the exposure parameters (kVp and mA). A 10 × 5 cm2 field of view was selected for average adult. Five scans were taken with varying kVp (70-90 kVp) first at fixed 4 mA. After assessment of the scans and selecting the best kVp, nine scans were taken with 2-12 mA, and the kVp was fixed at the optimal value. A clinical assessment of the implant-related anatomical landmarks was done in random order by two blinded examiners. Quantitative image quality was assessed for noise/uniformity, artifact added value, contrast-to-noise ratio, spatial resolution, and geometrical distortion. A dosimetry index phantom and thimble ion chamber were used to measure the absorbed dose for each scan setting. The anatomical landmarks of the maxilla had good image quality at all kVp settings. To produce good quality images, the mandibular landmarks demanded higher exposure parameters than the maxillary landmarks. The quantitative image quality values were acceptable at all selected exposure settings. Changing the exposure parameters does not necessarily produce higher image quality outcomes but does affect the radiation dose to the patient. The image quality could be optimized for implant treatment planning at lower exposure settings and dose than the default settings.
Collapse
Affiliation(s)
- Yasmine Alawaji
- Department of Oral Biological and Medical Sciences, Faculty of DentistryThe University of British ColumbiaBritish ColumbiaCanada
| | - David S. MacDonald
- Department of Oral Biological and Medical Sciences, Faculty of DentistryThe University of British ColumbiaBritish ColumbiaCanada
| | - Georgios Giannelis
- Department of Oral Biological and Medical Sciences, Faculty of DentistryThe University of British ColumbiaBritish ColumbiaCanada
| | - Nancy L. Ford
- Department of Oral Biological and Medical Sciences, Faculty of DentistryThe University of British ColumbiaBritish ColumbiaCanada
- Department of Physics and Astronomy, Faculty of ScienceThe University of British ColumbiaBritish ColumbiaCanada
| |
Collapse
|
16
|
Dach E, Bergauer B, Seidel A, von Wilmowsky C, Adler W, Lell M, Wichmann M, Matta RE. Impact of voxel size and scan time on the accuracy of three-dimensional radiological imaging data from cone-beam computed tomography. J Craniomaxillofac Surg 2018; 46:2190-2196. [PMID: 30318325 DOI: 10.1016/j.jcms.2018.09.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Revised: 06/06/2018] [Accepted: 09/10/2018] [Indexed: 12/18/2022] Open
Abstract
PURPOSE Three-dimensional (3D) radiological imaging plays an important role in surgical planning used in modern dentistry. The aim of this study was to optimize imaging parameters with a special focus on voxel size and scan time. MATERIAL AND METHODS A virtual 3D master model of a macerated human skull was generated using an industrial optical noncontact white light scanner. The skull was X-rayed with cone-beam computed tomography that was applied using different settings for voxel size and acquisition time (voxel edge length of 0.3 mm, scan times 4.8 s and 8.9 s; voxel edge length of 0.2 mm, scan times 14.7 s and 26.9 s). The scan was repeated 10 times at each setting. The CBCT scans were converted into 3D virtual models (actual value), which were superimposed with the 3D master model (reference value) to detect absolute differences. RESULTS The mean value of deviation increased with increasing voxel size and decreasing scan time. For a voxel edge length of 0.3 mm, the mean values of deviation were 0.33 mm and 0.22 mm with scan times of 4.8 s and 8.9 s, respectively. For a voxel edge length of 0.2 mm, the mean deviations were 0.16 mm and 0.14 mm with scan times of 14.7 s and 26.9 s, respectively. CONCLUSIONS When using small voxel sizes, the scan time does not have a significant impact on image accuracy and therefore the scan time can be shortened. However, for larger voxel sizes, shorter scan times can lead to increased inaccuracy.
Collapse
Affiliation(s)
- Eva Dach
- Department of Prosthodontics (Head: Professor Dr. M. Wichmann), Erlangen University Hospital, Glückstraße 11, 91054, Erlangen, Germany
| | - Bastian Bergauer
- Department of Prosthodontics (Head: Professor Dr. M. Wichmann), Erlangen University Hospital, Glückstraße 11, 91054, Erlangen, Germany
| | - Anna Seidel
- Department of Prosthodontics (Head: Professor Dr. M. Wichmann), Erlangen University Hospital, Glückstraße 11, 91054, Erlangen, Germany
| | - Cornelius von Wilmowsky
- Department of Oral and Maxillofacial Surgery (Head: Professor Dr. med. Dr. med. Dent. M. Kesting), Erlangen University Hospital, Glückstraße 11, 91054, Erlangen, Germany
| | - Werner Adler
- Department of Medical Informatics, Biometry and Epidemiology (Head: Professor Dr. O. Gefeller), Friedrich-Alexander-University of Erlangen-Nürnberg, Universitätsstraße 22, 91054, Erlangen, Germany
| | - Michael Lell
- Institute of Radiology and Nuclear Medicine (Head: Professor Dr. M. Lell), Klinikum Nürnberg, Paracelsus Medical University, Prof.-Ernst-Nathan-Straße 1, 90419, Nürnberg, Germany
| | - Manfred Wichmann
- Department of Prosthodontics (Head: Professor Dr. M. Wichmann), Erlangen University Hospital, Glückstraße 11, 91054, Erlangen, Germany
| | - Ragai-Edward Matta
- Department of Prosthodontics (Head: Professor Dr. M. Wichmann), Erlangen University Hospital, Glückstraße 11, 91054, Erlangen, Germany.
| |
Collapse
|
17
|
Panmekiate S, Rungwittayathon P, Suptaweeponboon W, Tangtraitham N, Pauwels R. Optimization of exposure parameters in dental cone beam computed tomography using a 3-step approach. Oral Surg Oral Med Oral Pathol Oral Radiol 2018; 126:545-552. [PMID: 30237039 DOI: 10.1016/j.oooo.2018.08.004] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2017] [Revised: 03/17/2018] [Accepted: 08/13/2018] [Indexed: 01/23/2023]
Abstract
OBJECTIVE The aim of this study was to find the optimal balance among tube voltage (kV), tube current (mA), and exposure time (s) in cone beam computed tomography (CBCT). STUDY DESIGN Three human hemimandibles were scanned by using the 3D Accuitomo 170 scanner (J. Morita, Kyoto, Japan). First, 3 combinations of kilovolt (kV) and milliampere (mA) were used at a constant radiation dose. Seven observers evaluated the images; the kV of the highest-scoring scan was considered optimal. Second, the lowest acceptable mA for visualizing different anatomic structures was determined. Finally, the samples were scanned by using 3 combinations of tube current and exposure time; the observers determined the combination with the highest image quality. RESULTS At a constant radiation dose, the highest available voltage (i.e., 90 kV) resulted in the highest image quality in terms of general impression, sharpness, noise, and artefacts. Depending on the anatomic structure, mA reductions of 20% to 40% compared with the default setting were possible. Fast-scan protocols showed equal or slightly better image quality compared with the standard-scan mode. CONCLUSIONS For the CBCT model used in this study, optimization implies the use of the highest kV along with the shortest exposure time and a task-specific mA. The proposed stepwise optimization approach could be applied to any CBCT unit, preferably during commissioning.
Collapse
Affiliation(s)
- Soontra Panmekiate
- Department of Radiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Peera Rungwittayathon
- Department of Radiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Wijuck Suptaweeponboon
- Department of Radiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Nattarus Tangtraitham
- Department of Radiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Ruben Pauwels
- Department of Radiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand; OMFS-IMPATH Research Group, Faculty of Medicine, Department of Imaging and Pathology, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium; Mechanical Engineering Department, Catholic University of Leuven, Leuven, Belgium.
| |
Collapse
|
18
|
Ozemre MO, Gulsahi A. Comparison of the accuracy of full head cone beam CT images obtained using a large field of view and stitched images. Dentomaxillofac Radiol 2018; 47:20170454. [PMID: 29851353 DOI: 10.1259/dmfr.20170454] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Abstract
OBJECTIVE: The aim of this study was to investigate the accuracy of the new stitching feature of the Morita 3D Accuitomo device by comparing it with the I-CAT device and real measurements. METHODS: Eight dry skulls were used in this study. The full scan mode of an I-CAT device and the new stitching feature of the Morita 3D Accuitomo device were used to obtain full head cone beam CT (CBCT) images, and the linear distances between the selected anatomical sites were measured by two observers. The real distances were measured directly on the skulls using digital calipers. Statistical analyses were performed using the intraclass correlation coefficient and Bland-Altman Limits of Agreement. RESULTS: High or perfect agreement was detected between the CBCT images and real measurements. The Bland-Altman Limits of Agreement analysis revealed that the stitched coronal and sagittal images of the Morita might differ by >1.54-1.67 or <0.01 mm from the real measurements. CONCLUSIONS: The stitched images of the Morita CBCT device showed perfect agreement with both real measurements and the images of an I-CAT full head scan. After the evaluation of the radiation doses received from stitching sectional images, this device may be used to obtain full head images.
Collapse
Affiliation(s)
- Mehmet Ozgur Ozemre
- 1 Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Baskent University , Ankara , Turkey
| | - Ayse Gulsahi
- 1 Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Baskent University , Ankara , Turkey
| |
Collapse
|
19
|
Bornstein MM, Horner K, Jacobs R. Use of cone beam computed tomography in implant dentistry: current concepts, indications and limitations for clinical practice and research. Periodontol 2000 2018; 73:51-72. [PMID: 28000270 DOI: 10.1111/prd.12161] [Citation(s) in RCA: 83] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Diagnostic radiology is an essential component of treatment planning in the field of implant dentistry. This narrative review will present current concepts for the use of cone beam computed tomography imaging, before and after implant placement, in daily clinical practice and research. Guidelines for the selection of three-dimensional imaging will be discussed, and limitations will be highlighted. Current concepts of radiation dose optimization, including novel imaging modalities using low-dose protocols, will be presented. For preoperative cross-sectional imaging, data are still not available which demonstrate that cone beam computed tomography results in fewer intraoperative complications such as nerve damage or bleeding incidents, or that implants inserted using preoperative cone beam computed tomography data sets for planning purposes will exhibit higher survival or success rates. The use of cone beam computed tomography following the insertion of dental implants should be restricted to specific postoperative complications, such as damage of neurovascular structures or postoperative infections in relation to the maxillary sinus. Regarding peri-implantitis, the diagnosis and severity of the disease should be evaluated primarily based on clinical parameters and on radiological findings based on periapical radiographs (two dimensional). The use of cone beam computed tomography scans in clinical research might not yield any evident beneficial effect for the patient included. As many of the cone beam computed tomography scans performed for research have no direct therapeutic consequence, dose optimization measures should be implemented by using appropriate exposure parameters and by reducing the field of view to the actual region of interest.
Collapse
|
20
|
Abstract
Cone beam computed tomography (CBCT) can be a useful adjunct to conventional plain film radiography, but its use must be carefully justified as the radiation dose is generally higher. Factors affecting the dose include the field of view (FOV) size, the exposure factors, the angle of rotation and voxel size. Once justified, the exposure should be fully optimised to ensure the dose to the patient is kept as low as possible while ensuring there is no reduction in the diagnostic yield. The European Commission (EC) and the Faculty of General Dental Practice (FGDP)(UK) have published selection criteria on the use of CBCT in dentistry. This article provides an overview of CBCT and summarises the latest guidance on selection criteria relevant to the general dental practitioner.
Collapse
|
21
|
Tsapaki V. Radiation protection in dental radiology – Recent advances and future directions. Phys Med 2017; 44:222-226. [DOI: 10.1016/j.ejmp.2017.07.018] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2017] [Revised: 07/21/2017] [Accepted: 07/22/2017] [Indexed: 10/19/2022] Open
|
22
|
Optimization of Tube Current in Cone-beam Computed Tomography for the Detection of Vertical Root Fractures with Different Intracanal Materials. J Endod 2017; 43:1668-1673. [DOI: 10.1016/j.joen.2017.04.003] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2017] [Revised: 04/01/2017] [Accepted: 04/02/2017] [Indexed: 01/28/2023]
|
23
|
Tangari-Meira R, Vancetto JR, Dovigo LN, Tosoni GM. Influence of Tube Current Settings on Diagnostic Detection of Root Fractures Using Cone-beam Computed Tomography: An In Vitro Study. J Endod 2017; 43:1701-1705. [PMID: 28818444 DOI: 10.1016/j.joen.2017.05.008] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2017] [Revised: 04/30/2017] [Accepted: 05/15/2017] [Indexed: 11/28/2022]
Abstract
INTRODUCTION This study assessed the influence of tube current settings (milliamperes [mA]) on the diagnostic detection of root fractures (RFs) using cone-beam computed tomographic (CBCT) imaging. METHOD Sixty-eight human anterior and posterior teeth were submitted to root canal preparation, and 34 root canals were filled. The teeth were divided into 2 groups: the control group and the fractured group. RFs were induced using a universal mechanical testing machine; afterward, the teeth were placed in a phantom. Images were acquired using a Scanora 3DX unit (Soredex, Tuusula, Finland) with 5 different mA settings: 4.0, 5.0, 6.3, 8.0, and 10.0. Two examiners (E1 and E2) classified the images according to a 5-point confidence scale. Intra- and interexaminer reproducibility was assessed using the kappa statistic; diagnostic performance was assessed using the area under the receiver operating characteristic curve (AUROC). RESULTS Intra- and interexaminer reproducibility showed substantial (κE1 = 0.791 and κE2 = 0.695) and moderate (κE1 × E2 = 0.545) agreement, respectively. AUROC was significantly higher (P ≤ .0389) at 8.0 and 10.0 mA and showed no statistical difference between the 2 tube current settings. CONCLUSIONS Tube current has a significant influence on the diagnostic detection of RFs in CBCT images. Despite the acceptable diagnosis of RFs using 4.0 and 5.0 mA, those settings had lower discrimination abilities when compared with settings of 8.0 and 10.0 mA.
Collapse
Affiliation(s)
- Ricardo Tangari-Meira
- Department of Oral Diagnosis and Surgery, School of Dentistry, São Paulo State University (Unesp), Araraquara, São Paulo, Brazil.
| | - José Ricardo Vancetto
- Department of Oral Diagnosis and Surgery, School of Dentistry, São Paulo State University (Unesp), Araraquara, São Paulo, Brazil
| | - Lívia Nordi Dovigo
- Department of Social Dentistry, School of Dentistry, São Paulo State University (Unesp), Araraquara, São Paulo, Brazil
| | - Guilherme Monteiro Tosoni
- Department of Oral Diagnosis and Surgery, School of Dentistry, São Paulo State University (Unesp), Araraquara, São Paulo, Brazil
| |
Collapse
|
24
|
Al-Okshi A, Theodorakou C, Lindh C. Dose optimization for assessment of periodontal structures in cone beam CT examinations. Dentomaxillofac Radiol 2017; 46:20160311. [PMID: 27910717 PMCID: PMC5606266 DOI: 10.1259/dmfr.20160311] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2016] [Revised: 11/23/2016] [Accepted: 11/28/2016] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES To investigate the relationship between dose and image quality for a dedicated dental CBCT scanner using different scanning protocols and to set up an optimal imaging protocol for assessment of periodontal structures. METHODS Radiation dose and image quality measurements were made using 3D Accuitomo 170 (J. Morita, Kyoto, Japan) dental CBCT scanner. The SedentexCT IQ phantom was used to investigate the relationship between contrast-to-noise ratio (CNR) and dose-area product. Subjective image quality assessment was achieved using a small adult skull phantom for the same range of exposure settings. Five independent observers assessed the images for three anatomical landmarks using a three-point visual grade analysis. RESULTS When correlating the CNR of each scanning protocol to the exposure parameters used to obtain it, CNR decreased as these parameters decreased, especially current-exposure time product. When correlating to subjective image quality, the CNR level remained acceptable when 5 mA and 17.5 s or greater was selected and 80 kV could be used without compromising the CNR. CONCLUSIONS For a dedicated CBCT unit, changing the rotation angle from 360° to 180° degrades image quality. By altering tube potential and current for the 360° rotation protocol, assessment of periodontal structures can be performed with a smaller dose without substantially affecting visualization.
Collapse
Affiliation(s)
- Ayman Al-Okshi
- Department of Oral and Maxillofacial Radiology, Faculty of Odontology, Malmö University, Malmö, Sweden
- Department of Oral Medicine and Radiology, Faculty of Dentistry, Sebha University, Sebha, Libya
| | - Chrysoula Theodorakou
- Christie Medical Physics and Engineering, The Christie NHS Foundation Trust, Manchester Academic Health Science Centre, Manchester, UK
| | | |
Collapse
|
25
|
Takeshita Y, Shimizu M, Okamura K, Yoshida S, Weerawanich W, Tokumori K, Jasa GR, Yoshiura K. A new method to evaluate image quality of CBCT images quantitatively without observers. Dentomaxillofac Radiol 2017; 46:20160331. [PMID: 28045343 DOI: 10.1259/dmfr.20160331] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES To develop an observer-free method for quantitatively evaluating the image quality of CBCT images by applying just-noticeable difference (JND). METHODS We used two test objects: (1) a Teflon (polytetrafluoroethylene) plate phantom attached to a dry human mandible; and (2) a block phantom consisting of a Teflon step phantom and an aluminium step phantom. These phantoms had holes with different depths. They were immersed in water and scanned with a CB MercuRay (Hitachi Medical Corporation, Tokyo, Japan) at tube voltages of 120 kV, 100 kV, 80 kV and 60 kV. Superimposed images of the phantoms with holes were used for evaluation. The number of detectable holes was used as an index of image quality. In detecting holes quantitatively, the threshold grey value (ΔG), which differentiated holes from the background, was calculated using a specific threshold (the JND), and we extracted the holes with grey values above ΔG. The indices obtained by this quantitative method (the extracted hole values) were compared with the observer evaluations (the observed hole values). In addition, the contrast-to-noise ratio (CNR) of the shallowest detectable holes and the deepest undetectable holes were measured to evaluate the contribution of CNR to detectability. RESULTS The results of this evaluation method corresponded almost exactly with the evaluations made by observers. The extracted hole values reflected the influence of different tube voltages. All extracted holes had an area with a CNR of ≥1.5. CONCLUSIONS This quantitative method of evaluating CBCT image quality may be more useful and less time-consuming than evaluation by observation.
Collapse
Affiliation(s)
- Yohei Takeshita
- 1 Department of Oral and Maxillofacial Radiology, Faculty of Dental Science, Kyushu University, Fukuoka, Japan
| | - Mayumi Shimizu
- 2 Department of Oral and Maxillofacial Radiology, Kyushu University Hospital, Fukuoka, Japan
| | - Kazutoshi Okamura
- 1 Department of Oral and Maxillofacial Radiology, Faculty of Dental Science, Kyushu University, Fukuoka, Japan
| | - Shoko Yoshida
- 3 Section of Image Diagnostics, Department of Diagnostics and General Care, Fukuoka Dental College, Fukuoka, Japan
| | - Warangkana Weerawanich
- 1 Department of Oral and Maxillofacial Radiology, Faculty of Dental Science, Kyushu University, Fukuoka, Japan
| | - Kenji Tokumori
- 4 Department of Radiological Technology, Faculty of Fukuoka Medical Technology, Teikyo University, Fukuoka, Japan
| | - Gainer R Jasa
- 5 Oral Radiology Division, Faculty of Dentistry, Republic University, Montevideo, Uruguay
| | - Kazunori Yoshiura
- 1 Department of Oral and Maxillofacial Radiology, Faculty of Dental Science, Kyushu University, Fukuoka, Japan
| |
Collapse
|
26
|
Choi JW. Analysis of the priority of anatomic structures according to the diagnostic task in cone-beam computed tomographic images. Imaging Sci Dent 2016; 46:245-249. [PMID: 28035302 PMCID: PMC5192022 DOI: 10.5624/isd.2016.46.4.245] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2016] [Revised: 07/18/2016] [Accepted: 07/23/2016] [Indexed: 12/04/2022] Open
Abstract
Purpose This study was designed to evaluate differences in the required visibility of anatomic structures according to the diagnostic tasks of implant planning and periapical diagnosis. Materials and Methods Images of a real skull phantom were acquired under 24 combinations of different exposure conditions in a cone-beam computed tomography scanner (60, 70, 80, 90, 100, and 110 kV and 4, 6, 8, and 10 mA). Five radiologists evaluated the visibility of anatomic structures and the image quality for diagnostic tasks using a 6-point scale. Results The visibility of the periodontal ligament space showed the closest association with the ability to use an image for periapical diagnosis in both jaws. The visibility of the sinus floor and canal wall showed the closest association with the ability to use an image for implant planning. Variations in tube voltage were associated with significant differences in image quality for all diagnostic tasks. However, tube current did not show significant associations with the ability to use an image for implant planning. Conclusion The required visibility of anatomic structures varied depending on the diagnostic task. Tube voltage was a more important exposure parameter for image quality than tube current. Different settings should be used for optimization and image quality evaluation depending on the diagnostic task.
Collapse
Affiliation(s)
- Jin-Woo Choi
- Department of Oral and Maxillofacial Radiology, Dankook University College of Dentistry, Chungnam, Korea
| |
Collapse
|