Influence of dual-mobility acetabular implants on revision and survivorship of cup and Kerboull-type reinforcement ring constructs in aseptic acetabular loosening.
Orthop Traumatol Surg Res 2022;
108:103071. [PMID:
34560312 DOI:
10.1016/j.otsr.2021.103071]
[Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Revised: 02/02/2021] [Accepted: 03/23/2021] [Indexed: 02/03/2023]
Abstract
INTRODUCTION
Dual-mobility (DM) acetabular implants have been used in revision total hip arthroplasty (THA) to prevent postoperative instability, with excellent mid-term survivorship. However, few comparative studies assessed the long-term outcomes of DM implants used in Kerboull-type reinforcement ring constructs for acetabular revision. The present study aimed to compare long-term survivorship, dislocation rates and clinical outcome between DM acetabular implants and conventional single-bearing (SB) implants when cemented in a reinforcement ring.
HYPOTHESIS
Dual-mobility implants are associated with equivalent survivorship and lower dislocation rates than SB implants.
MATERIAL AND METHODS
A retrospective study included 60 revision THAs for aseptic loosening using a Kerboull-type reinforcement ring, and finally included 2 groups of 23 patients with either DM or SB cemented acetabular implants after matching for age, gender, BMI and preoperative Harris hip score. Mean follow-up was 10 years (range, 6-14 years). Acetabular implant survivorship, dislocation rate and radiographic failure incidence (>5mm migration, progressive radiolucency, graft non-integration, reinforcement ring breakage) were compared between the two groups. Clinical outcomes used the Harris hip score, the Postel-Merle d'Aubigné score and the Parker score.
RESULTS
Survivorship free of aseptic acetabular re-revision was 89% at 10 years, with no significant difference between DM and SB (91% and 86%, respectively; p=0.54). Single-bearing implants showed a hazard ratio for dislocation of 6.7 (95% CI, 1.5-29.6; p=0.01) compared to DM implants. There were no significant differences in radiologic failure (10-year survivorship 72% and 64%, respectively; p=0.88) or functional scores.
DISCUSSION
The present study confirmed the impact of dual-mobility implants in reducing long-term dislocation risk when used in Kerboull-type reinforcement ring constructs for acetabular aseptic revision, with no increased risk of re-revision compared to conventional single-bearing implants.
LEVEL OF EVIDENCE
III, comparative retrospective study.