1
|
Macheras GA, Argyrou C, Tzefronis D, Milaras C, Tsivelekas K, Tsiamtsouris KG, Kateros K, Papadakis SA. Intraoperative calprotectin lateral flow immunoassay can assist decision-making between one- and two-stage revision total hip arthroplasty for patients with suspected periprosthetic joint infection. Bone Joint J 2024; 106-B:118-124. [PMID: 38688513 DOI: 10.1302/0301-620x.106b5.bjj-2023-0848.r1] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/02/2024]
Abstract
Aims Accurate diagnosis of chronic periprosthetic joint infection (PJI) presents a significant challenge for hip surgeons. Preoperative diagnosis is not always easy to establish, making the intraoperative decision-making process crucial in deciding between one- and two-stage revision total hip arthroplasty (THA). Calprotectin is a promising point-of-care novel biomarker that has displayed high accuracy in detecting PJI. We aimed to evaluate the utility of intraoperative calprotectin lateral flow immunoassay (LFI) in THA patients with suspected chronic PJI. Methods The study included 48 THAs in 48 patients with a clinical suspicion of PJI, but who did not meet European Bone and Joint Infection Society (EBJIS) PJI criteria preoperatively, out of 105 patients undergoing revision THA at our institution for possible PJI between November 2020 and December 2022. Intraoperatively, synovial fluid calprotectin was measured with LFI. Cases with calprotectin levels ≥ 50 mg/l were considered infected and treated with two-stage revision THA; in negative cases, one-stage revision was performed. At least five tissue cultures were obtained; the implants removed were sent for sonication. Results Calprotectin was positive (≥ 50 mg/l) in 27 cases; out of these, 25 had positive tissue cultures and/or sonication. Calprotectin was negative in 21 cases. There was one false negative case, which had positive tissue cultures. Calprotectin showed an area under the curve of 0.917, sensitivity of 96.2%, specificity of 90.9%, positive predictive value of 92.6%, negative predictive value of 95.2%, positive likelihood ratio of 10.6, and negative likelihood ratio of 0.04. Overall, 45/48 patients were correctly diagnosed and treated by our algorithm, which included intraoperative calprotectin measurement. This yielded a 93.8% concordance with postoperatively assessed EBJIS criteria. Conclusion Calprotectin can be a valuable tool in facilitating the intraoperative decision-making process for cases in which chronic PJI is suspected and diagnosis cannot be established preoperatively.
Collapse
Affiliation(s)
- George A Macheras
- 7th Department of Orthopaedic Surgery, Henry Dunant Hospital Center, Athens, Greece
| | - Chrysoula Argyrou
- 4th Department of Orthopaedic Surgery and Traumatology, KAT Attica General Hospital, Athens, Greece
| | - Dimitrios Tzefronis
- 7th Department of Orthopaedic Surgery, Henry Dunant Hospital Center, Athens, Greece
| | - Christos Milaras
- 7th Department of Orthopaedic Surgery, Henry Dunant Hospital Center, Athens, Greece
| | - Konstantinos Tsivelekas
- 2nd Department of Orthopaedic Surgery and Traumatology, KAT Attica General Hospital, Athens, Greece
| | | | | | - Stamatios A Papadakis
- 2nd Department of Orthopaedic Surgery and Traumatology, KAT Attica General Hospital, Athens, Greece
| |
Collapse
|
2
|
Cao H, Chen Y, Ge L, Kwong JSW, Lai H, Hu F, Zhang R, Zhao H, Hu L, He R, Zheng W, Zhang J. An umbrella review of the diagnostic value of next-generation sequencing in infectious diseases. Int J Clin Pharm 2024:10.1007/s11096-024-01704-2. [PMID: 38570474 DOI: 10.1007/s11096-024-01704-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Accepted: 01/18/2024] [Indexed: 04/05/2024]
Abstract
BACKGROUND An increasing number of systematic reviews (SRs) have evaluated the diagnostic values of next-generation sequencing (NGS) in infectious diseases (IDs). AIM This umbrella analysis aimed to assess the potential risk of bias in existing SRs and to summarize the published diagnostic values of NGS in different IDs. METHOD We searched PubMed, Embase, and the Cochrane Library until September 2023 for SRs assessing the diagnostic validity of NGS for IDs. Two investigators independently determined review eligibility, extracted data, and evaluated reporting quality, risk of bias, methodological quality, and evidence certainty in the included SRs. RESULTS Eleven SRs were analyzed. Most SRs exhibited a moderate level of reporting quality, while a serious risk of bias was observed in all SRs. The diagnostic performance of NGS in detecting pneumocystis pneumonia and periprosthetic/prosthetic joint infection was notably robust, showing excellent sensitivity (pneumocystis pneumonia: 0.96, 95% CI 0.90-0.99, very low certainty; periprosthetic/prosthetic joint infection: 0.93, 95% CI 0.83-0.97, very low certainty) and specificity (pneumocystis pneumonia: 0.96, 95% CI 0.92-0.98, very low certainty; periprosthetic/prosthetic joint infection: 0.95, 95% CI 0.92-0.97, very low certainty). NGS exhibited high specificity for central nervous system infection, bacterial meningoencephalitis, and tuberculous meningitis. The sensitivity to these infectious diseases was moderate. NGS demonstrated moderate sensitivity and specificity for multiple infections and pulmonary infections. CONCLUSION This umbrella analysis indicates that NGS is a promising technique for diagnosing pneumocystis pneumonia and periprosthetic/prosthetic joint infection with excellent sensitivity and specificity. More high-quality original research and SRs are needed to verify the current findings.
Collapse
Affiliation(s)
- Hong Cao
- School of Pharmaceutical Sciences, Guizhou University, 2708 South of Huaxi Avenue Road, Guiyang, Guizhou Province, China
- Department of Pharmacy, Guizhou Provincial People's Hospital, No.83 Zhongshandong Road, Guiyang, Guizhou Province, China
| | - Yan Chen
- School of Pharmaceutical Sciences, Guizhou University, 2708 South of Huaxi Avenue Road, Guiyang, Guizhou Province, China
- Department of Pharmacy, Guizhou Provincial People's Hospital, No.83 Zhongshandong Road, Guiyang, Guizhou Province, China
| | - Long Ge
- Evidence-Based Social Science Research Center, School of Public Health, Lanzhou University, Lanzhou, China
- Key Laboratory of Evidence Based Medicine and Knowledge Translation of Gansu Province, No. 199, Donggang West Road, Chengguan District, Lanzhou City, Gansu Province, China
| | - Joey Sum-Wing Kwong
- Global Health Nursing, Graduate School of Nursing Science, St. Luke's International University, 10-1 Akashi-Cho, Chuo-Ku, Tokyo, 104-0044, Japan
| | - Honghao Lai
- Evidence-Based Social Science Research Center, School of Public Health, Lanzhou University, Lanzhou, China
- Key Laboratory of Evidence Based Medicine and Knowledge Translation of Gansu Province, No. 199, Donggang West Road, Chengguan District, Lanzhou City, Gansu Province, China
| | - Fangfang Hu
- Department of Laboratory, Guizhou Provincial People's Hospital, No.83 Zhongshandong Road, Guiyang, 550002, Guizhou Province, China
| | - Rui Zhang
- Department of Pharmacy, Guizhou Provincial People's Hospital, No.83 Zhongshandong Road, Guiyang, Guizhou Province, China
| | - Huaye Zhao
- Department of Pharmacy, Guizhou Provincial People's Hospital, No.83 Zhongshandong Road, Guiyang, Guizhou Province, China
| | - Linfang Hu
- Department of Pharmacy, Guizhou Provincial People's Hospital, No.83 Zhongshandong Road, Guiyang, Guizhou Province, China
| | - Rui He
- Experimental Cancer Medicine, Department of Laboratory Medicine, Karolinska Institute, Room 601, Novum PI 6, Hälsovägen 7, Huddinge, 14157, Stockholm, Sweden
| | - Wenyi Zheng
- Experimental Cancer Medicine, Department of Laboratory Medicine, Karolinska Institute, Room 601, Novum PI 6, Hälsovägen 7, Huddinge, 14157, Stockholm, Sweden
| | - Jiaxing Zhang
- Department of Pharmacy, Guizhou Provincial People's Hospital, No.83 Zhongshandong Road, Guiyang, Guizhou Province, China.
| |
Collapse
|
3
|
Wang Y, Li G, Ji B, Xu B, Zhang X, Maimaitiyiming A, Cao L. Diagnosis of periprosthetic joint infections in patients who have rheumatoid arthritis. Bone Joint Res 2023; 12:559-570. [PMID: 37704202 PMCID: PMC10499527 DOI: 10.1302/2046-3758.129.bjr-2022-0432.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/15/2023] Open
Abstract
Aims To investigate the optimal thresholds and diagnostic efficacy of commonly used serological and synovial fluid detection indexes for diagnosing periprosthetic joint infection (PJI) in patients who have rheumatoid arthritis (RA). Methods The data from 348 patients who had RA or osteoarthritis (OA) and had previously undergone a total knee (TKA) and/or a total hip arthroplasty (THA) (including RA-PJI: 60 cases, RA-non-PJI: 80 cases; OA-PJI: 104 cases, OA-non-PJI: 104 cases) were retrospectively analyzed. A receiver operating characteristic curve was used to determine the optimal thresholds of the CRP, ESR, synovial fluid white blood cell count (WBC), and polymorphonuclear neutrophil percentage (PMN%) for diagnosing RA-PJI and OA-PJI. The diagnostic efficacy was evaluated by comparing the area under the curve (AUC) of each index and applying the results of the combined index diagnostic test. Results For PJI prediction, the results of serological and synovial fluid indexes were different between the RA-PJI and OA-PJI groups. The optimal cutoff value of CRP for diagnosing RA-PJI was 12.5 mg/l, ESR was 39 mm/hour, synovial fluid WBC was 3,654/μl, and PMN% was 65.9%; and those of OA-PJI were 8.2 mg/l, 31 mm/hour, 2,673/μl, and 62.0%, respectively. In the RA-PJI group, the specificity (94.4%), positive predictive value (97.1%), and AUC (0.916) of synovial fluid WBC were higher than those of the other indexes. The optimal cutoff values of synovial fluid WBC and PMN% for diagnosing RA-PJI after THA were significantly higher than those of TKA. The specificity and positive predictive value of the combined index were 100%. Conclusion Serum inflammatory and synovial fluid indexes can be used for diagnosing RA-PJI, for which synovial fluid WBC is the best detection index. Combining multiple detection indexes can provide a reference basis for the early and accurate diagnosis of RA-PJI.
Collapse
Affiliation(s)
- Yulai Wang
- Department of Orthopaedics, First Affiliated Hospital of Xinjiang Medical University, Urumqi, China
| | - Guoqing Li
- Department of Orthopaedics, First Affiliated Hospital of Xinjiang Medical University, Urumqi, China
| | - Baochao Ji
- Department of Orthopaedics, First Affiliated Hospital of Xinjiang Medical University, Urumqi, China
| | - Boyong Xu
- Department of Orthopaedics, First Affiliated Hospital of Xinjiang Medical University, Urumqi, China
| | - Xiaogang Zhang
- Department of Orthopaedics, First Affiliated Hospital of Xinjiang Medical University, Urumqi, China
| | | | - Li Cao
- Department of Orthopaedics, First Affiliated Hospital of Xinjiang Medical University, Urumqi, China
| |
Collapse
|
4
|
Yilmaz MK, Abbaszadeh A, Tarabichi S, Azboy I, Parvizi J. Diagnosis of Periprosthetic Joint Infection: The Utility of Biomarkers in 2023. Antibiotics (Basel) 2023; 12:1054. [PMID: 37370373 DOI: 10.3390/antibiotics12061054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 06/11/2023] [Accepted: 06/12/2023] [Indexed: 06/29/2023] Open
Abstract
Periprosthetic joint infection (PJI) is a rare yet devastating complication following total joint arthroplasty (TJA). Early and accurate diagnosis of PJI is paramount in order to maximize the chances of successful treatment. However, we are yet to identify a single "gold standard" test for the diagnosis of PJI. As a result, the diagnosis of PJI is often challenging. Currently, the 2018 ICM definition of PJI is the only validated diagnostic criteria available. This article will review the importance of serum and synovial biomarkers in the diagnosis of PJI. In addition, it will provide a brief overview of the emerging modalities for the identification of infections in this setting.
Collapse
Affiliation(s)
- Mehmet Kursat Yilmaz
- Rothman Orthopaedic Institute, Thomas Jefferson University, Philadelphia, PA 19107, USA
- Department of Orthopaedics and Traumatology, School of Medicine, Istanbul Medipol University, Istanbul 34810, Turkey
| | - Ahmad Abbaszadeh
- Rothman Orthopaedic Institute, Thomas Jefferson University, Philadelphia, PA 19107, USA
| | - Saad Tarabichi
- Rothman Orthopaedic Institute, Thomas Jefferson University, Philadelphia, PA 19107, USA
| | - Ibrahim Azboy
- Department of Orthopaedics and Traumatology, School of Medicine, Istanbul Medipol University, Istanbul 34810, Turkey
| | - Javad Parvizi
- Rothman Orthopaedic Institute, Thomas Jefferson University, Philadelphia, PA 19107, USA
| |
Collapse
|
5
|
Suren C, Lazic I, Haller B, Pohlig F, von Eisenhart-Rothe R, Prodinger P. The synovial fluid calprotectin lateral flow test for the diagnosis of chronic prosthetic joint infection in failed primary and revision total hip and knee arthroplasty. INTERNATIONAL ORTHOPAEDICS 2023; 47:929-944. [PMID: 36656361 PMCID: PMC10014771 DOI: 10.1007/s00264-023-05691-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Accepted: 01/04/2023] [Indexed: 01/20/2023]
Abstract
PURPOSE The diagnostic criteria of prosthetic joint infection (PJI) recommended by the most commonly used diagnostic algorithms can be obscured or distorted by other inflammatory processes or aseptic pathology. Furthermore, the most reliable diagnostic criteria are garnered during revision surgery. A robust, reliable addition to the preoperative diagnostic cascade is warranted. Calprotectin has been shown to be an excellent diagnostic marker for PJI. In this study, we aimed to evaluate a lateral flow test (LFT) in the challenging patient cohort of a national referral centre for revision arthroplasty. METHODS Beginning in March 2019, we prospectively included patients scheduled for arthroplasty exchange of a total hip (THA) or knee arthroplasty (TKA). Synovial fluid samples were collected intra-operatively. We used the International Consensus Meeting of 2018 (ICM) score as the gold standard. We then compared the pre-operative ICM score with the LFT result to calculate its diagnostic accuracy as a standalone pre-operative marker and in combination with the ICM score as part of an expanded diagnostic workup. RESULTS A total of 137 patients with a mean age of 67 (± 13) years with 53 THA and 84 TKA were included. Ninety-nine patients (72.8%) were not infected, 34 (25.0) were infected, and four (2.9%) had an inconclusive final score and could not be classified after surgery. The calprotectin LFT had a sensitivity (95% confidence interval) of 0.94 (0.80-0.99) and a specificity of 0.87 (0.79-0.93). The area under the receiver operating characteristic curve (AUC) for the calprotectin LFT was 0.94 (0.89-0.99). In nine cases with an inconclusive pre-operative ICM score, the calprotectin LFT would have led to the correct diagnosis of PJI. CONCLUSIONS The synovial fluid calprotectin LFT shows excellent diagnostic metrics both as a rule-in and a rule-out test, even in a challenging patient cohort with cases of severe osteolysis, wear disease, numerous preceding surgeries, and poor soft tissue conditions, which can impair the common diagnostic criteria. As it is available pre-operatively, this test might prove to be a very useful addition to the diagnostic algorithm.
Collapse
Affiliation(s)
- Christian Suren
- Center for Orthopedics, Trauma Surgery and Sports Medicine, München Klinik Bogenhausen, Englschalkinger Str. 77, 81925, Munich, Germany.
| | - Igor Lazic
- Department of Orthopedics and Sports Orthopedics, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - Bernhard Haller
- Artificial Intelligence and Informatics in Medicine (AIIM), Klinikum rechts der Isar, Technical University Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - Florian Pohlig
- Department of Orthopedics and Sports Orthopedics, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - Rüdiger von Eisenhart-Rothe
- Department of Orthopedics and Sports Orthopedics, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - Peter Prodinger
- Department of Trauma Surgery and Orthopedics, Norbert-Kerkel-Platz, Krankenhaus Agatharied, Hausham, Germany
| |
Collapse
|
6
|
Evaluation of Synovial Calprotectin by Using a Lateral Flow Test for the Diagnosis of Prosthetic Joint Infections. Diagnostics (Basel) 2023; 13:diagnostics13040741. [PMID: 36832229 PMCID: PMC9954940 DOI: 10.3390/diagnostics13040741] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 02/14/2023] [Accepted: 02/14/2023] [Indexed: 02/18/2023] Open
Abstract
The analysis of synovial fluid is a crucial step in the diagnosis of prosthetic joint infections (PJIs). Recently several studies illustrated the efficacy of synovial calprotectin in supporting the diagnosis of PJI. In this study, synovial calprotectin was analyzed by a commercial stool test to explore whether it might accurately predict PJIs. The synovial fluids of 55 patients were analyzed and calprotectin levels were compared to other synovial biomarkers of PJI. Of the 55 synovial flu-ids, 12 patients were diagnosed with PJI and 43 with an aseptic failure of the implant. Specificity, sensitivity, and AUC of calprotectin resulted in 0.944, 0.80, and 0.852 (95%CI: 0.971-1.00), respectively, with a set threshold of 529.5 µg/g. Calprotectin had a statistically relevant correlation with the synovial leucocyte counts (rs = 0.69, p < 0.001) and the percentage of synovial neutrophils (rs = 0.61, p < 0.001). From this analysis, it can be concluded that synovial calprotectin is a valuable biomarker that correlates with other established indicators of local infection, and the use of a commercial lateral flow stool test could be a cost-effective strategy delivering rapid and reliable results and supporting the diagnostic process of PJI.
Collapse
|
7
|
Fisher CR, Patel R. Profiling the Immune Response to Periprosthetic Joint Infection and Non-Infectious Arthroplasty Failure. Antibiotics (Basel) 2023; 12:antibiotics12020296. [PMID: 36830206 PMCID: PMC9951934 DOI: 10.3390/antibiotics12020296] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 01/20/2023] [Accepted: 01/29/2023] [Indexed: 02/04/2023] Open
Abstract
Arthroplasty failure is a major complication of joint replacement surgery. It can be caused by periprosthetic joint infection (PJI) or non-infectious etiologies, and often requires surgical intervention and (in select scenarios) resection and reimplantation of implanted devices. Fast and accurate diagnosis of PJI and non-infectious arthroplasty failure (NIAF) is critical to direct medical and surgical treatment; differentiation of PJI from NIAF may, however, be unclear in some cases. Traditional culture, nucleic acid amplification tests, metagenomic, and metatranscriptomic techniques for microbial detection have had success in differentiating the two entities, although microbiologically negative apparent PJI remains a challenge. Single host biomarkers or, alternatively, more advanced immune response profiling-based approaches may be applied to differentiate PJI from NIAF, overcoming limitations of microbial-based detection methods and possibly, especially with newer approaches, augmenting them. In this review, current approaches to arthroplasty failure diagnosis are briefly overviewed, followed by a review of host-based approaches for differentiation of PJI from NIAF, including exciting futuristic combinational multi-omics methodologies that may both detect pathogens and assess biological responses, illuminating causes of arthroplasty failure.
Collapse
Affiliation(s)
- Cody R. Fisher
- Mayo Clinic Graduate School of Biomedical Sciences, Department of Immunology, Mayo Clinic, Rochester, MN 55905, USA
- Division of Clinical Microbiology, Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN 55905, USA
| | - Robin Patel
- Division of Clinical Microbiology, Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN 55905, USA
- Division of Public Health, Infectious Diseases, and Occupational Medicine, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Correspondence:
| |
Collapse
|
8
|
Qin L, Zhao C, Wang H, Yang J, Chen L, Su X, Wei L, Zhang T, Li J, Jian C, Hu N, Huang W. Detection of inguinal lymph nodes is promising for the diagnosis of periprosthetic joint infection. Front Cell Infect Microbiol 2023; 13:1129072. [PMID: 37187468 PMCID: PMC10175641 DOI: 10.3389/fcimb.2023.1129072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Accepted: 04/18/2023] [Indexed: 05/17/2023] Open
Abstract
Background Localized inguinal lymphadenopathy often represents lower extremity pathogen infection, while normalized lymphadenopathy is associated with infection regression. We hypothesized that inguinal lymph nodes (LNs) were enlarged in Periprosthetic Joint Infection (PJI) patients and that normalized inguinal LNs would be a promising way to determine the timing of reimplantation. Methods We prospectively enrolled 176 patients undergoing primary and revision hip or knee arthroplasty. All patients underwent ultrasound examination of inguinal LNs preoperatively. The diagnostic value of inguinal LNs in PJI was evaluated by the receiver operating characteristic (ROC) curve. Results The median level of inguinal LNs was 26mm in the revision for PJI group compared with 12 mm in the aseptic revision group (p< 0.0001). The size of the inguinal LNs well distinguishes PJI from aseptic failure (AUC= 0.978) compare with ESR (AUC= 0.707) and CRP (AUC= 0.760). A size of 19mm was determined as the optimal threshold value of the inguinal LNs for the diagnosis of PJI, with a sensitivity of 92% and specificity of 96%. Conclusion Ultrasonic analysis of inguinal LNs is a valuable piece of evidence for the diagnosis of PJI and evaluation of persistent infection.
Collapse
Affiliation(s)
- Leilei Qin
- Department of Orthopaedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
- Orthopedic Laboratory, Chongqing Medical University, Chongqing, China
| | - Chen Zhao
- Department of Orthopaedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
- Orthopedic Laboratory, Chongqing Medical University, Chongqing, China
| | - Hai Wang
- Department of Orthopaedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
- Department of Orthopaedics, Fuling Central Hospital Affiliated of Chongqing University, Chongqing, China
| | - Jianye Yang
- Department of Orthopaedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
- Orthopedic Laboratory, Chongqing Medical University, Chongqing, China
| | - Li Chen
- Department of Orthopaedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
- Orthopedic Laboratory, Chongqing Medical University, Chongqing, China
| | - Xudong Su
- Department of Orthopaedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
- Orthopedic Laboratory, Chongqing Medical University, Chongqing, China
| | - Li Wei
- Department of Orthopaedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
- Orthopedic Laboratory, Chongqing Medical University, Chongqing, China
| | - Tao Zhang
- Department of Orthopaedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
- Orthopedic Laboratory, Chongqing Medical University, Chongqing, China
| | - Jia Li
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Changchun Jian
- Department of Orthopaedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
- Department of Orthopedics, Affiliated Hospital of North Sichuan Medical College, Sichuan, China
| | - Ning Hu
- Department of Orthopaedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
- Orthopedic Laboratory, Chongqing Medical University, Chongqing, China
- *Correspondence: Ning Hu, ; Wei Huang,
| | - Wei Huang
- Department of Orthopaedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
- Orthopedic Laboratory, Chongqing Medical University, Chongqing, China
- *Correspondence: Ning Hu, ; Wei Huang,
| |
Collapse
|
9
|
Synovial Fluid Interleukin Levels Cannot Distinguish between Prosthetic Joint Infection and Active Rheumatoid Arthritis after Hip or Knee Arthroplasty. Diagnostics (Basel) 2022; 12:diagnostics12051196. [PMID: 35626351 PMCID: PMC9140440 DOI: 10.3390/diagnostics12051196] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Revised: 04/26/2022] [Accepted: 05/04/2022] [Indexed: 02/04/2023] Open
Abstract
Inflammatory arthritis affects the level of synovial inflammatory factors, which makes it more difficult to diagnose prosthetic joint infection (PJI) patients with inflammatory arthritis. The aim of this study was to analyze synovial interleukin levels to distinguish between PJI and active rheumatoid arthritis (RA) after a hip or knee arthroplasty. From September 2019 to September 2021, we prospectively enrolled patients with joint pain after arthroplasty due to aseptic prosthesis loosening (n = 39), acute RA (n = 26), and PJI (n = 37). Synovial fluid from the affected joint is obtained and tested with a standard enzyme-linked immunosorbent assay. Receiver operating characteristic curve (ROC) was analyzed for each biomarker. Interleukin (IL)-1β, IL-6, and IL-8 showed promising value in differentiating of aseptic loosening from PJI, with areas under the curves (AUCs) of 0.9590, 0.9506, and 0.9616, respectively. Synovial IL-1β, IL-6, and IL-8 showed limited value in distinguishing between PJI and acute episodes of RA after arthroplasty, with AUCs of 0.7507, 0.7069, and 0.7034, respectively. Interleukins showed satisfactory efficacy in differentiating aseptic loosening from PJI. However, when pain after arthroplasty results from an acute episode of RA, current synovial interleukin levels do not accurately rule out the presence of PJI.
Collapse
|