1
|
Long-term Results of Primary Hip Arthroplasty with Cup Inclination Angle Bigger than Fifty Degrees. J Clin Orthop Trauma 2018; 9:133-136. [PMID: 29896015 PMCID: PMC5995005 DOI: 10.1016/j.jcot.2017.03.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND Most of studies suggest the cup inclination angle is controversial. All of the studies previous have not control the prosthesis type and head diameter, it is difficult to determine relative or synergistic effects of cup angle. METHODS We retrospectively reviewed 54 patients (61 hips) with primary total hip arthroplasties which cup inclination angle bigger than 500 after a mean 11.8 years follow-up. All the prosthesis are noncemented cup with a 28 mm metal head(Trilogy Acetabular Shell, Zimmer). The cup inclination was divided into three groups, 50-550 in 26 hips, 55-600 in 21 hips, and bigger than 600 in 14 hips. An immediate postoperative radiograph was compared with a follow-up radiograph. The polyethylene wear rates and abduction of the acetabular cups was measured in all of the patients. RESULTS The preoperative mean Harris hip score improved from 47.36 to 94.3 points at 10 years. The survivorship of the cup was 100% at 10 years. The mean rate of liner wear was 0.144 ± 0.031 mm/y (0.105-0.178 mm/y) in cup inclination angle between 500-550, and 0.260 ± 0.043 mm/y (0.215-0.394 mm/y) in angle between 550-600, 0. 403 ± 0.016 mm/y (0.378-0.423 mm/y) in angle bigger than 600. The different cup inclination groups are different with liner and volumetric wear. CONCLUSION For the metal-on-polyethylene prostheses, the liner wear obvious correlate with cup inclination after angle bigger than 500. It can be concluded that the ideal abduction angle for metal-on-polyethylene prostheses should be less than 55° in hip total replacement.
Collapse
|
2
|
Tian JL, Sun L, Hu RY, Han W, Tian XB. Correlation of Cup Inclination Angle with Liner Wear for Metal-on-polyethylene in Hip Primary Arthroplasty. Orthop Surg 2017; 9:186-190. [PMID: 28557297 DOI: 10.1111/os.12337] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/27/2016] [Accepted: 10/27/2016] [Indexed: 12/01/2022] Open
Abstract
OBJECTIVES The relationship between cup inclination angle and liner wear is controversial. Most authors in the published literature agree that the ideal cup inclination is associated with lower inner wear; however, some disagree. All previous studies did not control for femoral head diameter and inclination, so it is difficult to assess the relative or synergistic effects of cup angle on outcomes. METHODS We retrospectively reviewed 154 patients (171 hips) with primary total hip arthroplasties performed from 2001 to 2004. All surgeries had been performed by the same physician team. A posterior approach was applied in all patients. All prostheses were non-cemented cups with a 28-mm metal head. Inclusion criteria included that the radiographic material was not completed or lost for primary or last follow up. Patients were divided into four groups according to different cup inclination angle. There were 108 hips with inclination angles below 50°; 35 hips with angles between 50° and 55°; 17 hips with angles between 55° and 60°; and 11 hips with angles greater than 60°. An immediate postoperative radiograph was compared with a follow-up radiograph. Clinical and radiographic data were collected on standardized hip evaluation forms preoperatively, 6 months after surgery and at yearly follow-up visits. Radiographs were digitized and enlarged 100%. After the radiographs were digitized, polyethylene wear rates and acetabular cup abduction were measured on all patients with Cavas 15.0 software. The results were analyzed using Student's two-tailed paired t-test with SPSS 11.5. RESULTS The preoperative mean Harris hip score improved from 45.36 to 93.5 points 10 years after surgery. No acetabular component was revised for aseptic loosening. Three patients (three hips) had to undergo bone grafting and a lined arthroplasty for severe osteolysis around the acetabular component. The rate of implant survival at 10 years with respect to loosening was 100%. The mean liner wear rate was 0.135 mm/year in cups with inclination angles below 50°, 0.144 mm/year between 50° and 55°, 0.260 mm/year between 55° and 60°, and 0.403 mm/year when the angle was greater than 60°. Liner wear increased when the cup angle was larger than 55° (P < 0.05). CONCLUSIONS For metal-on-polyethylene prostheses, liner wear correlates with cup inclination angle larger than 55°. The ideal abduction angle for metal-on-polyethylene prostheses is less than 55°.
Collapse
Affiliation(s)
- Jia-Liang Tian
- Department of Orthopaedics, Guizhou Provincial People's Hospital, Guizhou, China
| | - Li Sun
- Department of Orthopaedics, Guizhou Provincial People's Hospital, Guizhou, China
| | - Rui-Yin Hu
- Department of Orthopaedics, Guizhou Provincial People's Hospital, Guizhou, China
| | - Wei Han
- Department of Orthopaedics, Guizhou Provincial People's Hospital, Guizhou, China
| | - Xiao-Bin Tian
- Department of Orthopaedics, Guizhou Provincial People's Hospital, Guizhou, China
| |
Collapse
|
3
|
Haw JG, Battenberg AK, Huang DCT, Schmalzried TP. Wear Rates of Larger-Diameter Cross-Linked Polyethylene at 5 to 13 Years: Does Liner Thickness or Component Position Matter? J Arthroplasty 2017; 32:1381-1386. [PMID: 28007372 DOI: 10.1016/j.arth.2016.11.022] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2016] [Revised: 11/08/2016] [Accepted: 11/14/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Cross-linked polyethylene (XLPE) has demonstrated significantly reduced wear and osteolysis into the second decade for total hip arthroplasty. There is a relative paucity of data with ≥36-mm bearings. Issues include potential effects of reduced liner thickness and component position on wear, osteolysis, and mechanical failure of the bearing. METHODS Radiographs of 48 primary total hip arthroplasties with ≥36-mm modular XLPE bearings were analyzed at a minimum 5 years postoperative on serial radiographs using a validated, edge-detection-based algorithm. Subgroups were examined to assess the effect of bearing diameter, liner thickness, acetabular abduction angle, and acetabular anteversion on XLPE wear. RESULTS There was no significant difference in volumetric wear when subgroups were stratified by component factors: liner thickness (<6.5 mm vs ≥6.5 mm) 40.69 mm3/y vs 24.47 mm3/y, respectively (P = .315); acetabular component abduction angle (<45° vs ≥45°): 38.68 mm3/y vs 27.8 mm3/y, respectively (P = .522); acetabular anteversion (<20° vs ≥20°): 41.32 mm3/y vs 31.79 mm3/y, respectively (P = .521). There were no dislocations, mechanical failures, or revisions. There were 7 hips with volumetric wear rates ≥80 mm3/y; 1 had possible osteolysis. CONCLUSION Larger-diameter XLPE wear was not measurably affected by liner thickness, acetabular abduction angle, or acetabular anteversion. However, there is a trend for increasing volumetric wear with increasing bearing size. Wear outliers do occur, and continued follow-up of larger-diameter XLPE bearings is warranted.
Collapse
Affiliation(s)
- Jonathan G Haw
- Department of Orthopaedic Surgery, Harbor-UCLA Medical Center, Torrance, California
| | - Andrew K Battenberg
- Department of Orthopaedic Surgery, Harbor-UCLA Medical Center, Torrance, California
| | - Der-Chen T Huang
- Joint Replacement Institute at St. Vincent Medical Center, Los Angeles, California
| | - Thomas P Schmalzried
- Joint Replacement Institute at St. Vincent Medical Center, Los Angeles, California
| |
Collapse
|
4
|
Halma JJ, Señaris J, Delfosse D, Lerf R, Oberbach T, van Gaalen SM, de Gast A. Edge loading does not increase wear rates of ceramic-on-ceramic and metal-on-polyethylene articulations. J Biomed Mater Res B Appl Biomater 2014; 102:1627-38. [DOI: 10.1002/jbm.b.33147] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2013] [Revised: 11/10/2013] [Accepted: 03/06/2014] [Indexed: 12/12/2022]
Affiliation(s)
- Jelle J. Halma
- Department of Orthopedics; Clinical Orthopedic Research Center (CORC-mN), Diakonessenhuis Utrecht/Zeist, Bosboomstraat 1; 3582 KE Utrecht The Netherlands
| | - Jose Señaris
- Complexo Hospitalario Universitario de Santiago de Compostela; Spain
| | | | - Reto Lerf
- Innovation Group, Mathys Ltd Bettlach; Bettlach Switzerland
| | | | - Steven M. van Gaalen
- Department of Orthopedics; Clinical Orthopedic Research Center (CORC-mN), Diakonessenhuis Utrecht/Zeist, Bosboomstraat 1; 3582 KE Utrecht The Netherlands
| | - Arthur de Gast
- Department of Orthopedics; Clinical Orthopedic Research Center (CORC-mN), Diakonessenhuis Utrecht/Zeist, Bosboomstraat 1; 3582 KE Utrecht The Netherlands
| |
Collapse
|
5
|
Clement ND, Mitchell M, Trayner ME, Porter DE, Lawson GM, Burnett R. Accelerated polyethylene wear and early failure of the uncemented Reflection acetabular component: a ten to fifteen-year follow-up study. INTERNATIONAL ORTHOPAEDICS 2013; 37:2337-43. [PMID: 23974837 DOI: 10.1007/s00264-013-2058-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2013] [Accepted: 07/24/2013] [Indexed: 11/26/2022]
Abstract
PURPOSE The Reflection® second-generation uncemented acetabular component was designed to address increased rates of failure observed with the early acetabular designs. However, the reported survivorship of this acetabular component has been conflicting. The aim of this study was to describe the ten to 15-year survivorship and polyethylene wear rate for the uncemented Reflection® acetabular component performed as part of a primary total hip replacement. METHODS One hundred and four consecutive Reflection® uncemented acetabular components in 97 patients were identified from a prospective arthroplasty database with a minimum of ten years of follow-up. No patient was lost to follow-up. Mean cohort age was 59.1 years. RESULTS There were 24 revisions of the acetabular component. The all-cause survival rate at ten years was 77.2% [95% confidence interval (CI) 73.9-80.5]. Mean linear wear was 0.20 mm [standard deviation (SD) 0.08] per year and the volumetric wear was 106.2 mm(3) per year. At final follow-up, more than half the patients had osteolysis identified around the femoral component. The mean Oxford Hip Score was 35.6 (SD 9.8) at a mean follow-up of 11.9 years, with six (11.1%) excellent, 26 (48.1%) good, 17 (31.5%) fair and five (9.3%) poor outcomes. Despite the fact that more than a third had a fair or poor outcome, only four (7.4%) were not satisfied with their hip. CONCLUSIONS Due to the high rate of relatively asymptomatic polyethylene wear and osteolysis associated with this acetabular component, in our department, we now review all surviving patients both clinically and radiographically on an annual basis.
Collapse
Affiliation(s)
- Nicholas D Clement
- Department of Orthopaedics and Trauma, The Royal Infirmary of Edinburgh, Little France, Edinburgh, EH16 4SA, UK,
| | | | | | | | | | | |
Collapse
|
6
|
Harris WH. Edge loading has a paradoxical effect on wear in metal-on-polyethylene total hip arthroplasties. Clin Orthop Relat Res 2012; 470:3077-82. [PMID: 22644421 PMCID: PMC3462843 DOI: 10.1007/s11999-012-2330-7] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Edge wear is an adverse factor that can negatively impact certain THAs. In some metal-on-metal THAs, it can lead to adverse tissue reactions including aseptic lymphocytic vasculitis-associated lesions and even to pseudotumor formation. In some ceramic-on-ceramic THAs, it can lead to squeaking and/or stripe wear. Edge wear in metal-on-metal and ceramic-on-ceramic THAs can also be associated with accelerated wear across the articulation of these joints. QUESTIONS/PURPOSES I asked: Does edge wear occur in metal-on-polyethylene (MOP) articulations? And if so, does it increase joint wear? METHODS I examined the evidence in the literature for edge wear occurring in MOP THA and then assessed the evidence in the literature for data supporting the concept that edge wear in MOP hips could accelerate wear across the articulation over time. RESULTS Extensive data in the literature confirm edge wear is common in MOP THA. Surprisingly, the evidence does not support that it accelerates wear across the articulation. In fact, substantial data support the concept that it does not. CONCLUSIONS These observations suggest, in terms of edge wear accelerating overall wear, MOP articulation may have a privileged position compared to hard-on-hard THA articulations.
Collapse
Affiliation(s)
- William H. Harris
- Harris Orthopaedic Laboratory, Department of Orthopaedic Surgery, Harvard Medical School, Massachusetts General Hospital, 55 Fruit Street, GRJ1126, Boston, MA 02114 USA
| |
Collapse
|
7
|
Kadar T, Furnes O, Aamodt A, Indrekvam K, Havelin LI, Haugan K, Espehaug B, Hallan G. The influence of acetabular inclination angle on the penetration of polyethylene and migration of the acetabular component. ACTA ACUST UNITED AC 2012; 94:302-7. [DOI: 10.1302/0301-620x.94b3.27460] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
In this prospective study we studied the effect of the inclination angle of the acetabular component on polyethylene wear and component migration in cemented acetabular sockets using radiostereometric analysis. A total of 120 patients received either a cemented Reflection All-Poly ultra-high-molecular-weight polyethylene or a cemented Reflection All-Poly highly cross-linked polyethylene acetabular component, combined with either cobalt–chrome or Oxinium femoral heads. Femoral head penetration and migration of the acetabular component were assessed with repeated radiostereometric analysis for two years. The inclination angle was measured on a standard post-operative anteroposterior pelvic radiograph. Linear regression analysis was used to determine the relationship between the inclination angle and femoral head penetration and migration of the acetabular component. We found no relationship between the inclination angle and penetration of the femoral head at two years’ follow-up (p = 0.9). Similarly, our data failed to reveal any statistically significant correlation between inclination angle and migration of these cemented acetabular components (p = 0.07 to p = 0.9).
Collapse
Affiliation(s)
- T. Kadar
- Haukeland University Hospital, Department
of Orthopaedic Surgery, Jonas Liesvei 65, Bergen
5021, Norway
| | - O. Furnes
- Haukeland University Hospital, Department
of Orthopaedic Surgery, Jonas Liesvei 65, Bergen
5021, Norway
| | - A. Aamodt
- Trondheim University Hospital, Department
of Orthopaedic Surgery, PostBox 3250 Sluppen, Trondheim
NO-7006, Norway
| | | | - L. I. Havelin
- Haukeland University Hospital, Department
of Orthopaedic Surgery, Jonas Liesvei 65, Bergen
5021, Norway
| | - K. Haugan
- Trondheim University Hospital, Department
of Orthopaedic Surgery, PostBox 3250 Sluppen, Trondheim
NO-7006, Norway
| | - B. Espehaug
- Haukeland University Hospital, Department
of Orthopaedic Surgery, Jonas Liesvei 65, Bergen
5021, Norway
| | - G. Hallan
- Haukeland University Hospital, Department
of Orthopaedic Surgery, Jonas Liesvei 65, Bergen
5021, Norway
| |
Collapse
|
8
|
Kampa RJ, Hacker A, Griffiths E, Rosson JW. In vivo polyethylene wear of bilateral total hip replacements - cemented versus uncemented modular sockets. Hip Int 2011; 20:447-52. [PMID: 21157748 DOI: 10.1177/112070001002000406] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 07/19/2010] [Indexed: 02/04/2023]
Abstract
We assessed polyethylene wear and osteolysis in 15 patients (30 hips) undergoing staged bilateral total hip arthroplasties, who had a cemented arthroplasty on one side and a hybrid arthroplasty on the other. All factors apart from mode of acetabular component fixation were matched. Wear was measured radiographically using Livermore's technique. The mean clinical and radiological follow-up was 11.2 years for the cemented and 10.7 years for the hybrid arthroplasties. Mean annual linear wear rate was 0.09mm/year in the cemented sockets and 0.14mm/year in the uncemented sockets. This difference was statistically significant (p=0.03), confirming previous reports that the rate of polyethylene wear is increased in uncemented sockets. No periacetabular osteolysis was noted. Femoral osteolysis in zone 7 occurred in 3 hybrid arthroplasties. It appears not all patients are equally affected. These results are further discussed.
Collapse
Affiliation(s)
- Rebecca J Kampa
- Department of Orthopaedics, Royal Surrey County Hospital, Guildford, Surrey, UK.
| | | | | | | |
Collapse
|
9
|
Emms NW, Stockley I, Hamer AJ, Wilkinson JM. Long-term outcome of a cementless, hemispherical, press-fit acetabular component: survivorship analysis and dose-response relationship to linear polyethylene wear. ACTA ACUST UNITED AC 2010; 92:856-61. [PMID: 20513885 DOI: 10.1302/0301-620x.92b6.23666] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Between 1988 and 1998 we implanted 318 total hip replacements (THRs) in 287 patients using the Plasmacup (B. Braun Ltd, Sheffield, United Kingdom) and a conventional metal-on-polyethylene articulation. The main indications for THR were primary or secondary osteoarthritis. At follow-up after a mean 11.6 years (7.6 to 18.4) 17 patients had died and 20 could not be traced leaving a final series of 280 THRs in 250 patients. There were 62 revisions (22.1%) in 59 patients. A total of 43 acetabular shells (15.4%) had been revised and 13 (4.6%) had undergone exchange of the liner. The most frequent indications for revision were osteolysis and aseptic loosening, followed by polyethylene wear. The mean Kaplan-Meier survival of the Plasmacup was 91% at ten years and 58% at 14 years. Osteolysis was found around 36 (17.1%) of the 211 surviving shells. The median annual rate of linear wear in the surviving shells was 0.12 mm/year and 0.25 mm/year in those which had been revised (p < 0.001). Polyethylene wear was a strong independent risk factor for osteolysis and aseptic loosening. The percentage of patients with osteolysis increased proportionately with each quintile of wear-rate. There is a high late rate of failure of the Plasmacup. Patients with the combination of this prosthesis and bearing should be closely monitored after ten years.
Collapse
Affiliation(s)
- N W Emms
- Department of Orthopaedics, Northern General Hospital, Sheffield,UK
| | | | | | | |
Collapse
|
10
|
Acetabular polyethylene wear and acetabular inclination and femoral offset. Clin Orthop Relat Res 2009; 467:2895-900. [PMID: 19412648 PMCID: PMC2758973 DOI: 10.1007/s11999-009-0845-3] [Citation(s) in RCA: 221] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2008] [Accepted: 04/03/2009] [Indexed: 01/31/2023]
Abstract
UNLABELLED Restoration of femoral offset and acetabular inclination may have an effect on polyethylene (PE) wear in THA. We therefore assessed the effect of femoral offset and acetabular inclination (angle) on acetabular conventional (not highly cross-linked) PE wear in uncemented THA. We prospectively followed 43 uncemented THAs for a minimum of 49 months (mean, 64 months; range, 49-88 months). Radiographs were assessed for femoral offset, acetabular inclination, and conventional PE wear. The mean (+/- standard deviation) linear wear rate in all THAs was 0.14 mm/year (+/- 0.01 mm/year) and the mean volumetric wear rate was 53.1 mm(3)/year (+/- 5.5 mm(3)/year). In THAs with an acetabular angle less than 45 degrees , the mean wear was 0.12 mm/year (+/- 0.01 mm/year) compared with 0.18 mm/year (+/- 0.02 mm/year) in those with a reconstructed acetabular angle greater than 45 degrees . Reproduction of a reconstructed femoral offset to within 5 mm of the native femoral offset was associated with a reduction in conventional PE wear (0.12 mm/year versus 0.16 mm/year). Careful placement of the acetabular component to ensure an acetabular angle less than 45 degrees in the reconstructed hip allows for reduced conventional PE wear. LEVEL OF EVIDENCE Level II, prospective study. See Guidelines for Authors for a complete description of levels of evidence.
Collapse
|
11
|
Goosen JHM, Verheyen CCPM, Kollen BJ, Tulp NJA. In vivo wear reduction of argon compared to air sterilized UHMW-polyethylene liners. Arch Orthop Trauma Surg 2009; 129:879-85. [PMID: 18989687 DOI: 10.1007/s00402-008-0771-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2008] [Indexed: 12/01/2022]
Abstract
INTRODUCTION To date, no studies have been published that report on the in vivo advantages of sterilisation in argon (ARGON) versus air (AIR) of UHMWPE liners with respect to wear extend and pattern in uncemented total hip arthroplasty. METHOD Femoral penetration rates were measured in 93 AIR and 79 ARGON liners, during a mean follow-up of 8 (3-12) years. RESULTS During the first 3 years after implantation, both groups showed no differences in mean wear rate (P = 0.13). Thereafter, the ARGON liner demonstrated a decrease in wear rate of 0.04 mm/year from 4 to 6 years (P = 0.006), 0.14 mm/year from 7 to 9 years (P < 0.001), and 0.33 mm/year beyond 9 years follow-up (P = 0.015) compared to the AIR liner. One AIR acetabular component required revision.
Collapse
Affiliation(s)
- J H M Goosen
- Department of Orthopaedic Surgery and Traumatology, Isala Clinics, P.O. Box 10500, 8000 GM, Zwolle, The Netherlands.
| | | | | | | |
Collapse
|
12
|
Raj D, Jaiswal PK, Sharma BL, Fergusson CM. Long term results of the Corin C-Fit uncemented total hip arthroplasty in young patients. Arch Orthop Trauma Surg 2008; 128:1391-5. [PMID: 18176810 DOI: 10.1007/s00402-007-0557-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2007] [Indexed: 11/29/2022]
Abstract
INTRODUCTION We conducted a prospective study to evaluate the long-term results after Corin C-Fit uncemented total hip arthroplasty in young patients with hydroxyapatite or porous coated components. MATERIALS AND METHODS We prospectively followed 36 patients (38 hips) who had Corin C-Fit uncemented total hip arthroplasties by eight experienced consultant surgeons at two centres. The acetabular and femoral components were hydroxyapatite or porous coated. RESULTS The overall 10-year survival rate for the Corin C-Fit arthroplasty was 43%. The 10-year survivorship for the femoral implant was 56% and for the acetabular component 59%. CONCLUSION The evidence presented in this study suggests that the Corin C-Fit uncemented total hip arthroplasty has one of the highest mid- and long-term failure rates for both femoral and acetabular components in the literature. We believe this implant should not be used and patients who have had this form of total hip arthroplasty should be kept under regular review.
Collapse
Affiliation(s)
- D Raj
- Department of Orthopaedics, Royal Berkshire Hospital, Reading, Berkshire RG1 5AN, UK.
| | | | | | | |
Collapse
|
13
|
Wan Z, Boutary M, Dorr LD. The influence of acetabular component position on wear in total hip arthroplasty. J Arthroplasty 2008; 23:51-6. [PMID: 18165028 DOI: 10.1016/j.arth.2007.06.008] [Citation(s) in RCA: 145] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2006] [Accepted: 06/18/2007] [Indexed: 02/01/2023] Open
Abstract
Our experience has implicated cup inclination as an important factor in wear, whereas others have suggested that the hip center of rotation (COR) must be closely reestablished to reduce wear. We conducted a retrospective study to determine the relative importance of these 2 factors. One hundred thirty-nine total hip arthroplasties were studied after a mean follow-up of 9.2 years (range, 6-3 years). Forty-nine of 139 operated hips had a contralateral normal hip, which allowed the most accurate measurement of the influence of change in the COR. Wear was related to the inclination of the cup but not to a change in the COR. Secondarily, wear was less with a ceramic-polyethylene polyarticular surface than with metal-polyethylene. The importance of this data is related to cup implantation techniques. The hip COR can be moved superiorly and/or medially to permit cup inclination below 45 degrees with correct cup coverage.
Collapse
Affiliation(s)
- Zhinian Wan
- Arthritis Institute, Inglewood, CA 90301, USA
| | | | | |
Collapse
|