1
|
Pourzal R, Cip J, Rad E, Laurent MP, Berger RA, Jacobs JJ, Wimmer MA. Joint line elevation and tibial slope are associated with increased polyethylene wear in cruciate-retaining total knee replacement. J Orthop Res 2020; 38:1596-1606. [PMID: 32374428 PMCID: PMC7329363 DOI: 10.1002/jor.24710] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2019] [Revised: 03/15/2020] [Accepted: 04/23/2020] [Indexed: 02/04/2023]
Abstract
The purpose of this retrieval study was to determine the effect of implant positioning on wear, taking patient-related factors into account. Therefore, the volumetric material loss of 59 retrieved tibial liners was quantitatively determined using a coordinate measuring-machine. All retrievals were made of the same polyethylene and design by a single manufacturer. Using time in-situ and linear regression, a wear rate for each liner was determined and corrected for bedding-in. Backside damage was qualitatively scored. The following implant positioning parameters were obtained from radiographs: anatomical lateral-distal femoral angle, anatomical medial-proximal tibial angle, femoral tilt angle, and posterior tibial slope. The patella position was assessed by the Blackburne-Peel index and the Insall-Salvati ratio. Unlike the Insall-Salvati ratio, the Blackburne-Peel index is known to detect surgical joint line elevation. Using general linear modeling the most impactful factors on wear rate and backside damage was determined, thereby taking patient demographic factors into account. The mean volumetric wear rate was 11.6 mm3 /y. Wear decreased with older age (P = .021) and female sex (P = .001). The wear rate increased with joint line elevation as indicated from a decreased Blackburne-Peel index (P = .019), and increased with increased posterior tibial slope (P = .026). The backside damage score also increased with joint line elevation (P = .036). A Blackburne-Peel index decrease of 0.1, signifying joint line elevation, was found to increase the wear rate by 1.8 mm3 /y and increase back-sided wear. A high tibial slope (>7°) led to a 9.3 mm3 /y increase in wear rate compared with a low tibial slope (<3°). The results of this study demonstrate that tibial liner positioning has a significant impact on polyethylene wear with potential implications on osteolysis over time.
Collapse
Affiliation(s)
- Robin Pourzal
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Johannes Cip
- Department of Paediatric Orthopaedics, Children’s Hospital of Eastern Switzerland, St. Gallen, Switzerland
| | - Elmira Rad
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Michel P. Laurent
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Richard A. Berger
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Joshua J. Jacobs
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Markus A. Wimmer
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois
| |
Collapse
|
2
|
Danilyak VV, Klyuchevsky VV, Molodov MA, Goryunov EV, Marchenkova KV. Long-Term Results of Total Hip Arthroplasty with RM Classic Cups. TRAUMATOLOGY AND ORTHOPEDICS OF RUSSIA 2019. [DOI: 10.21823/2311-2905-2019-25-3-25-33] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
Relevance. The RM Classic monoblock titanium-coated polyethylene cup is widely used in the total hip arthroplasty. However, so far in Russia there has been no analysis of follow-up over 10 years for a limited number of patients in a single hospital. The aim of the study was to evaluate the long-term outcomes of total hip replacement with RM Classic acetabular component. Materials and Methods. The outcomes of 328 total hip arthroplasties (289 patients operated in the period from 1997 to 2007) with RM Classic cups were evaluated in a monocentral retrospective clinical study. The average follow-up period was 14.4 years. Revision procedure due to aseptic loosening, polyethylene wear or osteolysis was considered as the end point of the study. Results. 9 revisions during the short and medium follow-up periods (up to 10 years) were associated with malpositioning of RM Classic components and errors in surgical technique. The indications for later revision THA (19 cases) were polyethylene wear and aseptic loosening. Only in one case they were combined with pelvic bone osteolysis with the formation of III a defect according to W.G. Paprosky classification. Within 15 years the Kaplan-Meier survivorship of RM Classic cup was 92.5%. There was a statistically significant difference of the survival curves in the ceramic-on-poly against metal-on-poly bearings: 94.9% and 79.4%, respectively. The average Harris Hip Score was 88.6. Conclusion. RM Classic uncemented monoblock cup has proven its high efficiency and survival in 15 years follow-up period and over.
Collapse
|
3
|
Braun S, Vardag S, Mueller U, Schroeder S, Sonntag R, Bormann T, Gotterbarm T, Kretzer JP. Backside wear, particle migration and effectiveness of screw hole plugs in acetabular hip joint replacement with cross-linked polyethylene. Acta Biomater 2019; 97:239-246. [PMID: 31374340 DOI: 10.1016/j.actbio.2019.07.050] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2019] [Revised: 07/17/2019] [Accepted: 07/26/2019] [Indexed: 11/26/2022]
Abstract
In total hip arthroplasty, osteolysis of the acetabulum often occurs at the backside of cups in the area of screw holes, indicating a clinically relevant amount of polyethylene (PE) wear particles in this area. In order to avoid a possible migration of wear particles to the acetabulum-bone, screw hole plugs are provided for some implant systems. The aims of this study were to quantitatively determine backside wear and to investigate the migration behaviour of articulation-related wear particles in a cup system with open and closed screw holes by plugs. Titanium cup systems with backside holes for screw fixations were sinusoidally loaded with 2.7 kN. The articulation area was separated from the backside area of the cup. A defined amount of articulation-generated particles was added to the fluid of the articulation chamber. The fluids in the two chambers were separately filtered after 2 × 106 cycles for a particle analysis. Backside wear with noticeably small (65.6 ± 4.2 nm) and round PE particles was identified. With both open and closed screw holes, a migration of the articulating wear particles from the articulation area behind the cup could be observed. Backside wear was estimated to be below 1% of the articulated wear. Screw hole plugs did not effectively prevent the migration of PE wear particles behind the investigated cups. STATEMENT OF SIGNIFICANCE: Backside wear occurs in a proven cup-system. Furthermore, it was quantitatively observed that articulation-generated wear products could migrate from the articulating area along the cup/liner-interface through the screw holes behind the cup. An almost unimpeded particle migration to the acetabulum-bone, in conjunction with very small backside wear particles, could produce a clinically relevant amount of PE with respect to pelvic lysis. These findings highlight the importance of management to avoid particle migration in artificial hip cups. Therefore, primarily the use of screw hole plugs, as far as available for the respective cup-system, is recommended. The aim of avoiding particle migration by plugs, but also by using a sophisticated anchoring mechanism between cup and PE liner should continue in future.
Collapse
|
4
|
Braun S, Sonntag R, Schroeder S, Mueller U, Jaeger S, Gotterbarm T, Kretzer JP. Backside wear in acetabular hip joint replacement. Acta Biomater 2019; 83:467-476. [PMID: 30408561 DOI: 10.1016/j.actbio.2018.10.045] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2018] [Revised: 10/30/2018] [Accepted: 10/31/2018] [Indexed: 10/27/2022]
Abstract
INTRODUCTION Besides head-insert articulation in hip joint replacements, micro-motions between the backside of assembled polyethylene acetabular liners and the metal cup may cause additional wear. Pelvic osteolysis frequently occurs in the region of screw holes, and cup loosening hints to clinically relevant amounts of polyethylene backside wear. It has yet to be confirmed whether backside wear particles differ in size and morphology compared to articulating wear. Previous methods have been limited to subjective assessment of backside surface damages without consideration of wear debris. The aim of this study was to develop and validate a method for quantitative in vitro measurements of polyethylene backside wear in artificial hip cups and to characterize these wear particles for the first time. METHODS Titanium cup-systems (Plasmafit®Plus7, Aesculap, UHMWPE liner) were sinusoidally loaded (2.5 kN) and a torque of 5 Nm was simultaneously applied. The front and rear side of the cup were separated to isolate backside wear. After 2 × 106 cycles the surrounding fluid was filtered and a particle analysis was performed. RESULTS Backside wear had a particles size of 64.1 ± 1.9 nm and was verified as round and oval particles with partly rough outlines. An estimated total number of particles of 1.26 × 109 ± 1.67 × 108 per 106 cycles was determined. CONCLUSION Backside wear was estimated to be several times lower than published values of articulating wear. However, polyethylene backside wear particles represented significantly smaller particles with partly roughened outlines than articulating wear particles and may therefore cause higher biological response in macrophage-mediated bone resorption compared to articulated particles. STATEMENT OF SIGNIFICANCE Within this study, an analytical method for quantitative measuring polyethylene backside wear of artificial hip cups was successfully developed and validated for the first time. It could be shown that backside wear is still present, even in modern cup-systems. These findings can be further used for investigations of the osteolytic potential of polyethylene particles, for evaluating and improving new implant systems and to evaluate the effectiveness of screw hole plugs to prevent the particle migration to the acetabulum.
Collapse
|
5
|
Puente Reyna AL, Holderied M, Jäger M, Schilling C, Grupp TM. ARTICULATION AND BACKSIDE WEAR ANALYSIS AFTER LONG-TERM IN VITRO WEAR SIMULATION OF VITAMIN E STABILIZED POLYETHYLENE ACETABULAR LINERS WITH A PRESS-FIT LOCKING MECHANISM. ACTA ACUST UNITED AC 2018. [DOI: 10.21823/2311-2905-2018-24-2-29-40] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
A previous retrieval study analyzed the backside wear of short-term implanted liners against in vitro tested liners of similar life in service and showed comparable results among both groups, with no significant backside wear due to micro-motion.The purpose — to obtain a picture of the overall wear (articulation and backside surfaces) of 0.1% vitamin e blended polyethylene liners, with a locking mechanism based on a press-fit cone in combination with a rough titanium conical inner surface in the fixation area, under a 20 million cycles hip wear simulation.Materials and Methods. A semi-quantitative method was used in order to assess the damage on the backside of the liners and a 3d measuring machine to assess the creep and wear at the articulation surface.Results. The total average backside wear score was 22.00±2.59 from a maximum total score of 147 after 5 million cycles (mc), increased to 31.92±5.57 after 10 mc, but showed no further increment after 15 and 20 mc. The reference liners (subjected only to axial load) showed similar wear scores and modes as the liners under wear simulation (axial load and movement). Small scratches produced during insertion and removal were clearly seen at the rim (fixation) area and no considerable abrasion was observed. The machining marks on the convex surface were always visible. Regarding the articulation surface, a steady state wear rate of 7 µm/year was measured.Conlusion. These results determined that most of the backside wear produced on the liners occurred during their insertion and removal rather than during their life in service. Moreover, the wear at the articulation surface was similar to that seen in vivo at short- and mid-term on highly cross-linked polyethylene liners with and without vitamin e content.
Collapse
|
6
|
Moon JK, Kim Y, Hwang KT, Yang JH, Oh YH, Kim YH. Long-Term Outcomes After Metal-on-Metal Total Hip Arthroplasty With a 28-mm Head: A 17- to 23-Year Follow-Up Study of a Previous Report. J Arthroplasty 2018; 33:2165-2172. [PMID: 29656971 DOI: 10.1016/j.arth.2018.02.089] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2017] [Revised: 02/03/2018] [Accepted: 02/23/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Second-generation, metal-on-metal total hip arthroplasty (MoM THA) using a 28-mm head has shown favorable results compared with large head MoM THA. The purpose of this study is to evaluate the long-term outcomes of cementless primary MoM THA with a 28-mm head and the incidence of osteolysis using computed tomography. METHODS A total of 92 patients (53 men and 39 women) who underwent primary cementless MoM THA (114 hips) with a 28-mm head were enrolled in this study. Their mean age was 46.2 years at the time of surgery. The mean follow-up duration was 20 years. The Harris hip score, presence of thigh or groin pain, radiographic results, presence of peri-implant osteolysis, histologic analysis, and Kaplan-Meier survival curves were evaluated. RESULTS The mean preoperative Harris hip score of 50.5 improved to 85.1 at the final follow-up. Eight patients (8 hips) experienced groin pain, but none had thigh pain. Twelve revisions (6.2%) were performed including 10 hips for aseptic loosening with osteolysis and 2 hips for periprosthetic fracture around the stem. At 23 years, 91% of patients were free from revision of the acetabular component due to aseptic loosening and 90.1% were free from revision of both femoral and acetabular components due to any reason. Osteolysis was identified around the cup in 12 cases (10.5%) and around the stem in 7 cases (6.1%). CONCLUSION MoM THA with a 28-mm head showed a relatively low rate of aseptic implant loosening at a mean follow-up of 20 years.
Collapse
Affiliation(s)
- Jun-Ki Moon
- Department of Orthopedic Surgery, Hanyang University Guri Hospital, Guri, South Korea
| | - Yeesuk Kim
- Department of Orthopedic Surgery, Hanyang University Hospital, Seoul, South Korea
| | - Kyu-Tae Hwang
- Department of Orthopedic Surgery, Hanyang University Hospital, Seoul, South Korea
| | - Jae-Hyuk Yang
- Department of Orthopedic Surgery, Hanyang University Guri Hospital, Guri, South Korea
| | - Young-Ha Oh
- Department of Pathology, Hanyang University Guri Hospital, Guri, South Korea
| | - Young-Ho Kim
- Department of Orthopedic Surgery, Hanyang University Guri Hospital, Guri, South Korea
| |
Collapse
|
7
|
Backside Wear Analysis of Retrieved Acetabular Liners with a Press-Fit Locking Mechanism in Comparison to Wear Simulation In Vitro. BIOMED RESEARCH INTERNATIONAL 2016; 2016:8687131. [PMID: 27722174 PMCID: PMC5045999 DOI: 10.1155/2016/8687131] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/21/2016] [Accepted: 08/18/2016] [Indexed: 11/17/2022]
Abstract
Backside wear due to micromotion and poor conformity between the liner and its titanium alloy shell may contribute to the high rates of retroacetabular osteolysis and consequent aseptic loosening. The purpose of our study was to understand the wear process on the backside of polyethylene liners from two acetabular cup systems, whose locking mechanism is based on a press-fit cone in combination with a rough titanium conical inner surface on the fixation area. A direct comparison between in vitro wear simulator tests (equivalent to 3 years of use) and retrieved liners (average 13.1 months in situ) was done in order to evaluate the backside wear characteristics and behavior of these systems. Similar wear scores between in vitro tested and retrieved liners were observed. The results showed that this locking mechanism did not significantly produce wear marks at the backside of the polyethylene liners due to micromotion. In all the analyzed liners, the most common wear modes observed were small scratches at the cranial fixation zone directly below the rough titanium inner surface of the shell. It was concluded that most of the wear marks were produced during the insertion and removal of the liner, rather than during its time in situ.
Collapse
|
8
|
How Does Wear Rate Compare in Well-functioning Total Hip and Knee Replacements? A Postmortem Polyethylene Liner Study. Clin Orthop Relat Res 2016; 474:1867-75. [PMID: 26891896 PMCID: PMC4925408 DOI: 10.1007/s11999-016-4749-8] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2015] [Accepted: 02/10/2016] [Indexed: 01/31/2023]
Abstract
BACKGROUND The longevity of total hip (THR) and knee replacements (TKR) that used historical bearing materials of gamma-in-air sterilized UHMWPE was affected more by osteolysis in THRs than in TKRs, although osteolysis remains a concern in TKRs. Therefore, the study of polyethylene wear is still of interest for the knee, particularly because few studies have investigated volumetric material loss in tibial knee inserts. For this study, a unique collection of autopsy-retrieved TKR and THR components that were well-functioning at the time of retrieval was used to compare volumetric wear differences between hip and knee polyethylene components made from identical material. QUESTIONS/PURPOSES The following questions were addressed: (1) How much did the hip liners wear and what wear patterns did they exhibit? (2) How much did the knee inserts wear and what wear patterns did they exhibit? (3) What is the ratio between TKR and THR wear after controlling for implantation time and patient age? METHODS We compared 23 THR components (Harris-Galante [HG] and HG II) and 20 TKR components (Miller-Galante [MG II]) that were retrieved postmortem. The components were made from the same polyethylene formulation and with similar manufacturing and sterilization (gamma-in-air) processes. Twenty-one patients (12 males, nine females) had THRs and 16 (four males, 12 females) had TKRs. Patients who had TKRs had an older (p = 0.001) average age than patients who had THRs (age, 75 years; SD, 10, versus 66 years; SD, 12, respectively). Only well-functioning components were included in this study. Therefore, implants retrieved postmortem from physically active patients and implanted for at least 2 years were considered. In addition, only normally wearing TKR components were considered, ie, those with fatigue wear (delamination) were excluded. The wear volume of each component was measured using metrology. For the tibial inserts an autonomous mathematic reconstruction method was used for quantification. RESULTS The acetabular liners of the THR group had a wear rate of 38 mm(3) per year (95% CI, 29-47 mm(3)/year). Excluding patients with low-activity, the wear rate was 47 mm(3) per year (95% CI, 37-56 mm(3)/year). The wear rate of normally wearing tibial inserts was 17 mm(3) per year (95% CI, -6 to 40 mm(3)/year). After controlling for the relevant confounding variable of age, we found a TKR/THR wear rate ratio of 0.5 (95% CI, 0.29-0.77) at 70 years of age with a slightly increasing difference with increasing age. CONCLUSIONS Excluding delamination, TKRs exhibited lower articular wear rates than THRs for historical polyethylene in these two unique cohorts of postmortem retrievals. CLINICAL RELEVANCE The lower TKR wear rate is in line with the lower incidence of osteolysis in TKRs compared with THRs.
Collapse
|
9
|
Nich C. CORR Insights(®): Backside Wear Is Not Dependent on the Acetabular Socket Design in Crosslinked Polyethylene Liners. Clin Orthop Relat Res 2016; 474:383-5. [PMID: 26260395 PMCID: PMC4709286 DOI: 10.1007/s11999-015-4502-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2015] [Accepted: 08/04/2015] [Indexed: 01/31/2023]
Affiliation(s)
- Christophe Nich
- Department of Orthopaedic Surgery, Raymond Poincaré University Hospital, 104 Raymond Poincaré Blvd, Garches, 92380 France
| |
Collapse
|
10
|
Abstract
BACKGROUND Although it is understood that backside damage occurs in polyethylene acetabular liners, the effect of highly crosslinked polyethylene, which has completely replaced conventional polyethylene, has yet to be examined. QUESTIONS/PURPOSES The purpose of this study was to answer the following questions: (1) With conventional polyethylene (CPE), did the acetabular design make a difference in backside wear? (2) Is there a difference in backside damage between CPE and crosslinked polyethylene (XLPE) liners? (3) With XLPE, is the difference in backside wear between designs still present? (4) Is there any difference in backside damage in various zones on backside of individual liners? METHODS This single-institution retrieval analysis involved visual damage scoring on the backside of 233 polyethylene liners implanted between 2002 and 2011. The liners were retrieved from either polished/dovetail cups (PD) or roughened/wire cups (RW) made by two different manufacturers. The inserts were divided into four groups: PD-CPE (n = 105), PD-XLPE (n = 16), RW-CPE (n = 99), and RW-XLPE (n = 13). Aseptic loosening and polyethylene wear were the predominant reasons for revision of CPE liners, whereas instability and infection were the common reasons for revision of XLPE liners. The time in situ (TIS) was shorter for the XLPE liners as compared with the CPE liners (PD-CPE: 8.5 years [SD 4.4]; RD-CPE: 9.5 [SD 4.8]; PD-CPE: 3.8 [SD 3.7]; RD-XLPE: 4.0 [SD 4.3]). The backside of each liner was divided into five zones and graded initially from a scale of 0 to 3 for seven different damage modes by one observer. There was substantial interobserver (kappa 0.769) and intraobserver (0.736) reliability on repeat scoring. To compare the effects of crosslinking, a subset of the conventional polyethylene liners was matched to the crosslinked liners based on TIS, resulting in 16 per group for the two PD types and 13 per group for the two RW types. RESULTS Total damage scores in the RW-CPE (19 ± 7) group were greater (p < 0.001) than the PD-CPE group (8 ± 4). Damage was reduced with XLPE (p = 0.02) only for the RW-XLPE (9 ± 9) versus RW-CPE-type sockets (4 ± 4). There was no difference (p = 0.16) between the RW-XLPE group and the PD-XLPE group. Damage scores in the peripheral zone of the locking mechanisms were higher for RW-CPE (4 ± 3) compared with PD-CPE (1.4 ± 1.0, p < 0.001) and RW-XLPE (1.3 ± 1.3, p = 0.02). Damage was greater (p < 0.001) within the superior zones (7 ± 4) compared with the inferior zones (3.0 ± 2.8) of all liners. CONCLUSIONS The current study shows greater backside damage for CPE in the roughened, wire lock cups. XLPE was shown to be more resistant to backside damage for both socket designs. CLINICAL RELEVANCE Although the polished/dovetail cups seem to cause less backside damage in the CPE liners than roughened/wire cups, the use of XLPE liners has been shown to protect the liner from backside damage in either cup design. If an acetabular shell has a functional locking mechanism, surgeons should not worry about cup design when undertaking isolated liner revision using XLPE liners.
Collapse
|
11
|
Effects of Surface Modification and Bulk Geometry on the Biotribological Behavior of Cross-Linked Polyethylene: Wear Testing and Finite Element Analysis. BIOMED RESEARCH INTERNATIONAL 2015; 2015:435432. [PMID: 26583106 PMCID: PMC4637033 DOI: 10.1155/2015/435432] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/06/2015] [Accepted: 05/12/2015] [Indexed: 11/23/2022]
Abstract
The wear and creep deformation resistances of polymeric orthopedic bearing materials are both important for extending their longevity. In this study, we evaluated the wear and creep deformation resistances, including backside damage, of different polyethylene (PE) materials, namely, conventional PE, cross-linked PE (CLPE), and poly(2-methacryloyloxyethyl
phosphorylcholine)- (PMPC-) grafted CLPE, through wear tests and finite element analysis. The gravimetric and volumetric degrees of wear of disks (3 or 6 mm in thickness) of these materials against a cobalt-chromium-molybdenum alloy pin were examined using a multidirectional pin-on-disk tester. Cross-linking and PMPC grafting decreased the gravimetric wear of the PE disks significantly. The volumetric wear at the bearing surface and the volumetric penetration in the backside of the 3-mm thick PE disk were higher than those of the 6-mm thick PE disk, regardless of the bearing material. The geometrical changes induced in the PE disks consisted of creep, because the calculated internal von Mises stress at the bearing side of all disks and that at the backside of the 3-mm thick disks exceeded their actual yield strengths. A highly hydrated bearing surface layer, formed by PMPC grafting, and a cross-linking-strengthened substrate of adequate thickness are essential for increasing the wear and creep deformation resistances.
Collapse
|
12
|
Hwang KT, Kim YH, Kim YS, Ryu JA. Prevalence of a soft-tissue lesion after small head metal-on-metal total hip replacement: 13- to 19-year follow-up study. Bone Joint J 2015; 96-B:1594-9. [PMID: 25452360 DOI: 10.1302/0301-620x.96b12.33705] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
We investigated the incidence of soft-tissue lesions after small head metal-on-metal total hip replacement (MoM THR). Between December 1993 and May 1999, 149 patients (195 hips) underwent primary cementless MoM THR. During the follow-up period, three patients (five THRs) died and eight patients (14 THRs) were lost to follow-up. We requested that all patients undergo CT evaluation. After exclusion of five patients (six THRs) who had undergone a revision procedure, and 22 (28 THRs) who were unwilling to take part in this study, 111 patients (142 THRs) were evaluated. There were 63 men (88 THRs) and 48 women (54 THRs) with a mean age of 45.7 years (37 to 56) at the time of surgery. The mean follow-up was 15.4 years (13 to 19). A soft-tissue lesion was defined as an abnormal peri-prosthetic collection of fluid, solid lesion or asymmetrical soft-tissue mass. At final follow-up, soft-tissue lesions were found in relation to 28 THRs (19.7%), including 25 solid and three cystic lesions. They were found in 20 men and eight women; 26 lesions were asymptomatic and two were symptomatic. The mean maximal diameter of the soft-tissue lesion was 42.3 mm (17 to 135). The relatively high rate of soft-tissue lesions observed with small head MoM THR remains a concern.
Collapse
Affiliation(s)
- K T Hwang
- Department of Orthopaedic Surgery, Hanyang University, 222 Wangsimni-ro, Seongdong-gu, Seoul 133-791, Korea
| | - Y H Kim
- Department of Orthopaedic Surgery, Hanyang University, 153 Gyungchoon-ro, Guri-si, Gyunggi-do 471-701, Korea
| | - Y S Kim
- Department of Orthopaedic Surgery, Hanyang University, 222 Wangsimni-ro, Seongdong-gu, Seoul 133-791, Korea
| | - J A Ryu
- Department of Radiology, Hanyang University, 153 Gyungchoon-ro, Guri-si, Gyunggi-do 471-701, Korea
| |
Collapse
|
13
|
Trunnionosis: the latest culprit in adverse reactions to metal debris following hip arthroplasty. Skeletal Radiol 2015; 44:433-40. [PMID: 25109382 DOI: 10.1007/s00256-014-1978-3] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/12/2014] [Revised: 07/27/2014] [Accepted: 07/30/2014] [Indexed: 02/02/2023]
Abstract
The imaging findings of periprosthetic soft tissue lesions (pseudotumours) have been typically defined in the context of newer second-generation metal-on-metal hip arthroplasty. More recently, similar findings have been described in the setting of non-metal-on-metal prostheses. Although uncommon, wear and corrosion between the metal surfaces at the head-neck ('trunnionosis') and neck-stem interfaces are the potential culprits. With modular junctions containing at least one cobalt chromium component frequently present in hip arthroplasty prostheses, the incidence of this mode of adverse wear may be higher than previously thought (irrespective of the specific bearing couple used). In the present report, we described a case of a severe adverse local tissue reaction secondary to suspected corrosion at the head-neck taper in a metal-on-polyethylene total hip arthroplasty and reviewed the literature. Knowledge of this topical entity should help radiologists facilitate early diagnosis and ensure early management of this potentially serious complication.
Collapse
|
14
|
Glyn-Jones S, Thomas GER, Garfjeld-Roberts P, Gundle R, Taylor A, McLardy-Smith P, Murray DW. The John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial. Clin Orthop Relat Res 2015; 473:432-8. [PMID: 25123239 PMCID: PMC4294892 DOI: 10.1007/s11999-014-3735-2] [Citation(s) in RCA: 113] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND The use of highly crosslinked polyethylene (HXLPE) is now commonplace for total hip arthroplasty. Hip simulator studies and short-term in vivo measurements suggest that the wear rate of some types of HXLPE is significantly less than conventional ultrahigh-molecular-weight polyethylene (UHMWPE). However, there are few long-term data to support its use. QUESTIONS/PURPOSES The aim of this study was to measure the long-term steady-state wear of HXLPE compared with UHMWPE liners in a prospective, double-blind, randomized controlled trial using radiostereometric analysis. METHODS Fifty-four patients were randomized to receive hip arthroplasties with either UHMWPE liners or HXLPE liners. Complete followup was available on 39 of these patients (72%). All patients received the same cemented stem and an uncemented acetabular component. Three-dimensional penetration of the head into the socket was determined at 10 years using a radiostereometric analysis system, which has an in vivo accuracy of <0.1 mm. Oxford Hip Scores were compared between the groups. RESULTS At 10 years there was significantly less wear of HXLPE (0.003 mm/year; 95% confidence interval [CI], ±0.010; SD 0.023; range, -0.057 to 0.074) compared with UHMWPE (0.030 mm/year; 95% CI, ±0.012; p<0.001; SD 0.0.27; range, -0.001 to 0.164). The volumetric penetration from 1 to 10 years for the UHMWPE group was 98 mm3 (95% CI, ±46 mm3; SD 102 mm3; range, -4 to 430 mm3) compared with 14 mm3 (95% CI, ±40 mm3; SD 91 mm3; range, -189 to 242 mm3) for the HXLPE group (p=0.01). CONCLUSIONS This study demonstrates that HXLPE has little detectable steady-state in vivo wear. This may result in fewer reoperations from loosening; however, careful clinical followup into the second decade still needs to be performed. LEVEL OF EVIDENCE Level I, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Siôn Glyn-Jones
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, NIHR Musculoskeletal Biomedical Research Unit, Nuffield Orthopaedic Centre, University of Oxford, Windmill Road, Oxford, OX3 7LD UK
| | - Geraint E. R. Thomas
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, NIHR Musculoskeletal Biomedical Research Unit, Nuffield Orthopaedic Centre, University of Oxford, Windmill Road, Oxford, OX3 7LD UK
| | - Patrick Garfjeld-Roberts
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, NIHR Musculoskeletal Biomedical Research Unit, Nuffield Orthopaedic Centre, University of Oxford, Windmill Road, Oxford, OX3 7LD UK
| | - Roger Gundle
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, NIHR Musculoskeletal Biomedical Research Unit, Nuffield Orthopaedic Centre, University of Oxford, Windmill Road, Oxford, OX3 7LD UK
| | - Adrian Taylor
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, NIHR Musculoskeletal Biomedical Research Unit, Nuffield Orthopaedic Centre, University of Oxford, Windmill Road, Oxford, OX3 7LD UK
| | - Peter McLardy-Smith
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, NIHR Musculoskeletal Biomedical Research Unit, Nuffield Orthopaedic Centre, University of Oxford, Windmill Road, Oxford, OX3 7LD UK
| | - David W. Murray
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, NIHR Musculoskeletal Biomedical Research Unit, Nuffield Orthopaedic Centre, University of Oxford, Windmill Road, Oxford, OX3 7LD UK
| |
Collapse
|
15
|
Is there material loss at the backside taper in modular CoCr acetabular liners? Clin Orthop Relat Res 2015; 473:275-85. [PMID: 25318923 PMCID: PMC4390963 DOI: 10.1007/s11999-014-3982-2] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2013] [Accepted: 09/23/2014] [Indexed: 01/31/2023]
Abstract
BACKGROUND Metal wear and corrosion products generated by hip replacements have been linked to adverse local tissue reactions. Recent investigations of the stem/head taper junction have identified this modular interface as another possible source of metal debris; however, little is known regarding other modular metallic interfaces, their ability to produce metal debris, and possibly to provide insight in the mechanisms that produce metal debris. QUESTIONS/PURPOSES We asked three questions: (1) can we develop a reliable method to estimate volumetric material loss from the backside taper of modular metal-on-metal liners, (2) do backside tapers of modular metal-on-metal liners show a quantifiable volumetric material loss, and, if so, (3) how do regions of quantitatively identified material loss correspond to visual and microscopic investigations of surface damage? METHODS Twenty-one cobalt-chromium (CoCr) liners of one design and manufacturer were collected through an institutional review board-approved retrieval program. All liners were collected during revision surgeries, where the primary revision reason was loosening (n=11). A roundness machine measured 144 axial profiles equally spaced about the circumference of the taper region near the rim to estimate volume and depth of material loss. Sensitivity and repeatability analyses were performed. Additionally, visual and scanning electron microscopy investigations were done for three liners. RESULTS Our measurement method was found to be reproducible. The sensitivity (how dependent measurement results are on experimental parameters) and repeatability (how consistent results are between measurements) analyses confirmed that component alignment had no apparent effect (weak correlation, R2=0.04) on estimated volumetric material loss calculations. Liners were shown to have a quantifiable material loss (maximum=1.7 mm3). Visual investigations of the liner surface could identify pristine surfaces as as-manufactured regions, but could misidentify discoloration as a possible region of material loss. Scanning electron microscopy more accurately distinguished between as-manufactured and damaged regions of the taper. CONCLUSIONS The roundness machine has been used to develop a repeatable method for characterizing material loss; future work comparing a gravimetric standard with estimations of material loss determined from the roundness machine may show the accuracy and effectiveness of this method. Liners show rates of material loss that compare with those reported for other taper junctions. Visual inspection alone may misidentify as-manufactured regions as regions of material loss. CLINICAL RELEVANCE This study identifies the acetabular liner/shell interface in modular metal-on-metal devices as a potential source of metal wear or corrosion products. The relation between metal debris and clinical performance, regardless of the type of bearing couple, is a concern for clinicians. Therefore, it is important to characterize every type of modular junction to understand the quantity, location, and mechanism(s) of material loss.
Collapse
|
16
|
Tabata T, Kaku N, Hara K, Tsumura H. Initial stability of cementless acetabular cups: press-fit and screw fixation interaction--an in vitro biomechanical study. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2014; 25:497-502. [PMID: 25421640 PMCID: PMC4363363 DOI: 10.1007/s00590-014-1571-4] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/03/2014] [Accepted: 11/09/2014] [Indexed: 11/30/2022]
Abstract
Background
Press-fit and screw fixation are important technical factors to achieve initial stability of a cementless acetabular cup for good clinical results of total hip arthroplasty. However, how these factors affect one another in initial cup fixation remains unclear. Therefore, this study aimed to evaluate the mutual influence between press-fit and screw fixation on initial cup stability. Methods Foam bone was subjected to exact hemispherical-shape machining to diameters of 48, 48.5 and 49 mm. A compressive force was applied to ensure seating of a 48-mm-diameter acetabular cup in the foam bone prior to testing. Screws were inserted in six different conditions and tightened in a radial direction at the same torque strength. Then, the socket was rotated with a twist-testing machine, and the torque value at the start of axial rotation between the socket and the foam bone was measured under each screw condition. Results The torque values for the 48-mm-diameter reaming were >20 N m higher than those for the 48.5- and 49-mm-diameter reaming in each screw condition, indicating that press-fit fixation is stronger than screw fixation. Meanwhile, torque values for the 48.5- and 49-mm-diameter reaming tended to increase with increasing the number of screws. Conclusions According to our experiment, press-fit fixation of a cementless acetabular cup achieved rigid stability. Although the supplemental screws increased stability of the implant under good press-fit conditions, they showed little impact on whole-cup stability. In the case of insufficient press-fit fixation, cup stability depends on screw stability and increasing the number of additional screws increases cup stability.
Collapse
Affiliation(s)
- Tomonori Tabata
- Department of Orthopaedic Surgery, Faculty of Medicine, Oita University, Oita, 879-5593, Japan,
| | | | | | | |
Collapse
|
17
|
Hwang KT, Kim YH, Kim YS, Choi IY. Is second generation metal-on-metal primary total hip arthroplasty with a 28 mm head a worthy option?: a 12- to 18-year follow-up study. J Arthroplasty 2013; 28:1828-33. [PMID: 23890829 DOI: 10.1016/j.arth.2013.06.022] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/10/2013] [Revised: 05/28/2013] [Accepted: 06/15/2013] [Indexed: 02/01/2023] Open
Abstract
To determine whether MoM THA with a small head is still worthy of use, we investigated survivorship, complications, and factors influencing failure. Of 149 consecutive patients (195 hips), 141 (180 hips) of mean age 43 (19-55) years were available for review at a mean of 14.4 years postoperatively. Survivorship for cup revision for any cause was 97.8% at 18.4 years postoperatively. Nine hips generated complaints of groin pain; six showed periacetabular osteolysis, one had pain without radiological change, and two were diagnosed as symptomatic pseudotumors. Four of six hips with periacetabular osteolysis or aseptic loosening were revised. Surgery- and patient-related factors had no effect in results. Our results are encouraging, however, further study will be necessary to determine the incidence and fates of pseudotumors after MoM THA with a small head.
Collapse
Affiliation(s)
- Kyu-Tae Hwang
- Department of Orthopaedic Surgery, Hanyang University Hospital, Seoul, South Korea
| | | | | | | |
Collapse
|
18
|
Clauss M, Gersbach S, Butscher A, Ilchmann T. Risk factors for aseptic loosening of Müller-type straight stems: a registry-based analysis of 828 consecutive cases with a minimum follow-up of 16 years. Acta Orthop 2013; 84:353-9. [PMID: 23799347 PMCID: PMC3768033 DOI: 10.3109/17453674.2013.810517] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
Background and purpose Even small differences in design variables for the femoral stem may influence the outcome of a hip arthroplasty. We performed a risk factor analysis for aseptic loosening of 4 different versions of cemented Müller-type straight stems with special emphasis on design modifications (2 shapes, MSS or SL, and 2 materials, CoNiCrMo (Co) or Ti-6Al-7Nb (Ti)). Methods We investigated 828 total hip replacements, which were followed prospectively in our in-house register. All stems were operated in the same setup, using Sulfix-6 bone cement and a second-generation cementing technique. Demographic and design-specific risk factors were analyzed using an adjusted Cox regression model. Results The 4 versions showed marked differences in 15-year stem survival with aseptic loosening as the endpoint: 94% (95% CI: 89-99) for MSS Co, 83% (CI: 75-91) for SL Co, 81% (CI: 76-87) for MSS Ti and 63% (CI: 56-71) for SL Ti. Cox regression analysis showed a relative risk (RR) for aseptic loosening of 3 (CI: 2-5) for stems made of Ti and of 2 (CI: 1-2) for the SL design. The RR for aseptic stem loosening increased to 8 (CI: 4-15) when comparing the most and the least successful designs (MSS Co and SL Ti). Interpretation Cemented Müller-type straight stems should be MSS-shaped and made of a material with high flexural strength (e.g. cobalt-chrome). The surface finish should be polished (Ra < 0.4 µm). These technical aspects combined with modern cementing techniques would improve the survival of Müller-type straight stems. This may be true for all types of cemented stems.
Collapse
Affiliation(s)
- Martin Clauss
- Clinic for Orthopedic and Trauma Surgery, Kantonsspital Baselland Liestal
| | - Silke Gersbach
- Clinic for Orthopedic and Trauma Surgery, Kantonsspital Baselland Liestal
| | | | - Thomas Ilchmann
- Clinic for Orthopedic and Trauma Surgery, Kantonsspital Baselland Liestal
| |
Collapse
|
19
|
Urban RM, Hall DJ, Della Valle C, Wimmer MA, Jacobs JJ, Galante JO. Successful long-term fixation and progression of osteolysis associated with first-generation cementless acetabular components retrieved post mortem. J Bone Joint Surg Am 2012; 94:1877-85. [PMID: 23079880 PMCID: PMC3489071 DOI: 10.2106/jbjs.j.01507] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Primary cementless acetabular reconstruction has shown durable long-term fixation. Late failures secondary to aseptic loosening are rare but may occur in patients with previously well-fixed components. In the present study, the histopathological characteristics of postmortem specimens were correlated with wear damage and radiographic data in an attempt to better understand the long-term events in the periacetabular tissue around well-functioning devices. METHODS Seventeen primary cementless Harris-Galante I acetabular components with adjacent tissues were harvested after a mean of eleven years (range, four to twenty-five years) from patients whose implants were well functioning at the time of death. Undecalcified and paraffin sections were used to quantify the extent of bone and soft tissues within the porous coating and at the interface between the coating and the surrounding bone. Wear particles were identified with use of polarized light microscopy and energy-dispersive x-ray analysis. Bearing-surface volumetric wear and backside wear damage of the polyethylene liner were assessed. RESULTS All of the components were fixed by bone ingrowth (mean extent, 33% ± 21%). Particle-induced granulomas were present in the porous coating and along the interface and progressed through screw holes, ballooning into the retroacetabular bone in the longer-term specimens. Particles of femoral and acetabular origin were identified in the granulomas. Bearing-surface volumetric wear (mean, 41.6 mm3/year) increased with duration and correlated with increasing extent of granuloma in the porous coating and the increasing size of pelvic granulomas. Radiolucencies on radiographs correlated with the extent of bone and fibrous tissue ingrowth. Of the six pelvic granulomas that were identified histologically, only one was apparent on routine radiographs. CONCLUSIONS Acetabular fixation by bone ingrowth can be successful into the third decade after implantation. Osteolysis and secondary replacement of bone with particle-induced granuloma are commonly seen in the presence of excellent clinical function. Strategies designed to minimize bearing-surface wear and backside damage are important to maintain long-term bone ingrowth fixation.
Collapse
Affiliation(s)
- Robert M. Urban
- Department of Orthopedic Surgery, Rush University Medical Center, 1653 West Congress Parkway, Chicago, IL 60612
| | - Deborah J. Hall
- Department of Orthopedic Surgery, Rush University Medical Center, 1653 West Congress Parkway, Chicago, IL 60612
| | - Craig Della Valle
- Department of Orthopedic Surgery, Rush University Medical Center, 1653 West Congress Parkway, Chicago, IL 60612
| | - Markus A. Wimmer
- Department of Orthopedic Surgery, Rush University Medical Center, 1653 West Congress Parkway, Chicago, IL 60612
| | - Joshua J. Jacobs
- Department of Orthopedic Surgery, Rush University Medical Center, 1653 West Congress Parkway, Chicago, IL 60612
| | - Jorge O. Galante
- Department of Orthopedic Surgery, Rush University Medical Center, 1653 West Congress Parkway, Chicago, IL 60612
| |
Collapse
|
20
|
Randelli F, Banci L, D'Anna A, Visentin O, Randelli G. Cementless Metasul metal-on-metal total hip arthroplasties at 13 years. J Arthroplasty 2012; 27:186-92. [PMID: 21621954 DOI: 10.1016/j.arth.2011.04.015] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/15/2010] [Revised: 01/18/2011] [Accepted: 04/11/2011] [Indexed: 02/01/2023] Open
Abstract
Second-generation metal-on-metal bearings have been used since the late 1980s as alternative bearings to eliminate aseptic loosening due to polyethylene wear. The aim of the present study was to evaluate the long-term results of a series of Metasul (Zimmer GmbH, Winterthur, Switzerland) metal-on-metal total hip arthroplasty (THA). One hundred forty-nine cementless THAs with a 28-mm Metasul articulation were performed in 111 consecutive patients. The results were retrospectively reviewed at 13 years postoperatively. Clinical and radiographic evaluations and implant survivorship were performed. Seven hips (4.7%) were revised. The overall survivorship with revision for any reason as the end point was 0.94. The average Harris hip score was 91.4. Expansive osteolysis was found adjacent to the stem in 4 hips. Metal wear-related aseptic loosening was not the major reason for failure in our Metasul metal-on-metal THAs. Recurrent dislocation was the main reason for revision in our series.
Collapse
Affiliation(s)
- Filippo Randelli
- Divisione Ortopedia II, IRCCS Policlinico San Donato, 20097 San Donato Milanese, Milan, Italy
| | | | | | | | | |
Collapse
|
21
|
Pakvis D, Biemond L, van Hellemondt G, Spruit M. A cementless elastic monoblock socket in young patients: a ten to 18-year clinical and radiological follow-up. INTERNATIONAL ORTHOPAEDICS 2010; 35:1445-51. [PMID: 20820777 PMCID: PMC3174288 DOI: 10.1007/s00264-010-1120-7] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/07/2010] [Revised: 07/31/2010] [Accepted: 08/18/2010] [Indexed: 11/10/2022]
Abstract
The survival of acetabular components depends on several factors: wear, osteolysis and septic or aseptic loosening. Osteolysis seems to be the main cause for concern in cementless arthroplasties. Acetabular osteolysis results from particle debris and segmental unloading of acetabular bone by rigid sockets. We investigated a cementless elastic monoblock socket with regard to acetabular osteolysis and aseptic loosening in a cohort of young patients. We evaluated 158 hip arthroplasties with a minimum follow-up of ten years (ten to 18) and a mean age of 42 years (18–50). The overall revision rate at 14 years was 80% with a 98% survival rate for aseptic loosening. The mean polyethylene wear rate was 0.11 mm/year. Progressive acetabular osteolysis was seen in 3% of patients evaluated. In conclusion, we found low pelvic osteolysis rates, acceptable overall wear rates, satisfactory overall survival and excellent survival rates for aseptic loosening of a cementless elastic monoblock socket in patients younger than 50 years. Ongoing tribology developments and knowledge about acetabular bone adaptations behind acetabular implants will further lower wear and osteolysis rates and optimise survival rates of cementless sockets.
Collapse
Affiliation(s)
- Dean Pakvis
- Department of Orthopaedic Surgery, St. Maartenskliniek Hospital, P.O. Box 9011, 6500 GM, Nijmegen, The Netherlands.
| | | | | | | |
Collapse
|