1
|
Beckers G, Morcos MW, Lavigne M, Massé V, Kiss MO, Vendittoli PA. Excellent Results of Large-Diameter Ceramic-on-Ceramic Bearings in Total Hip Arthroplasty at Minimum Ten-Year Follow-up. J Arthroplasty 2024:S0883-5403(24)00644-2. [PMID: 38909852 DOI: 10.1016/j.arth.2024.06.045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Revised: 06/17/2024] [Accepted: 06/18/2024] [Indexed: 06/25/2024] Open
Abstract
AIMS This study reports the minimum 10 year results of total hip arthroplasty (THA) performed using a monoblock acetabular component with a large-diameter head (LDH) ceramic-on-ceramic (CoC) bearing. METHODS Of the 276 THAs included in this study, 237 (85%) were available for review at a mean of 10.5 years (range, 10 to 12) postoperatively. There were eleven deaths that occurred during the follow-up. Reoperations, implant revisions, adverse events, clinical outcomes, radiographic evaluation, and whole blood metal ion levels were assessed at the last follow-up. RESULTS After a minimum of 10 years, implant survivorship was 98.7%. There were three revisions (1.3%): one for insufficient acetabular cup primary fixation, one traumatic periprosthetic acetabular fracture, and one probable deep chronic infection. No dislocation or ceramic implant fracture was observed. The mean University of California at Los Angeles (UCLA) activity score, Western Ontario and McMaster Universities Osteoarthritis Index score, and Forgotten Joint Score were 5.6 (2 to 10), 90.1 (9 to 100), and 79.2 (4 to 100), respectively. In the 10 years following implantation, at least 43% of patients reported hearing a squeaking noise from the prosthesis. All patients who had squeaking hips were satisfied with the surgery. The mean titanium level was 2.2 μg/L (1.1 to 5.6). No progressive radiolucent lines, osteolysis, or implant loosening signs were observed at the last radiographic evaluation. CONCLUSION A LDH CoC THA provides outstanding long-term (minimum 10 year) implant survivorship with unrestricted activity while avoiding implant impingement, liner fracture, and hip instability. Functional outcomes, satisfaction, and joint perception were excellent. Although the incidence of squeaking was high, it did not affect patient satisfaction or function. The systemic titanium levels were low, related to unavoidable passive corrosion of implant surfaces, and did not reveal any indirect signs of trunnionosis.
Collapse
Affiliation(s)
- Gautier Beckers
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, 5415 Boulevard de l'Assomption, Montreal, QC, H1T 2M4, Canada
| | - Mina W Morcos
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, 5415 Boulevard de l'Assomption, Montreal, QC, H1T 2M4, Canada
| | - Martin Lavigne
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, 5415 Boulevard de l'Assomption, Montreal, QC, H1T 2M4, Canada; Clinique Orthopédique Duval, Laval, QC, H7M 2Y3, Canada
| | - Vincent Massé
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, 5415 Boulevard de l'Assomption, Montreal, QC, H1T 2M4, Canada; Clinique Orthopédique Duval, Laval, QC, H7M 2Y3, Canada
| | - Marc-Olivier Kiss
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, 5415 Boulevard de l'Assomption, Montreal, QC, H1T 2M4, Canada; Clinique Orthopédique Duval, Laval, QC, H7M 2Y3, Canada
| | - Pascal-André Vendittoli
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, 5415 Boulevard de l'Assomption, Montreal, QC, H1T 2M4, Canada; Clinique Orthopédique Duval, Laval, QC, H7M 2Y3, Canada; Personalized Arthroplasty Society, Atlanta, GA, 30305, USA.
| |
Collapse
|
2
|
López RE, Pelayo de Tomás JM, Morales Suárez Varela M, Rodrigo Pérez JL. Evolution of chromium and cobalt serum levels after the use of a modular neck stem in primary total hip arthroplasty. Rev Esp Cir Ortop Traumatol (Engl Ed) 2024; 68:26-34. [PMID: 37270057 DOI: 10.1016/j.recot.2023.05.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 03/23/2023] [Accepted: 05/29/2023] [Indexed: 06/05/2023] Open
Abstract
INTRODUCTION AND OBJECTIVES Modular neck primary stems were introduced with the theoretical advantage of restoring the hip anatomy more precisely. However, the presence of a second junction has been associated with increased corrosion and release of metal debris. The objective of our study is to quantify of chromium and cobalt serum values, and to analyze their temporal evolution during five years. MATERIAL AND METHODS We present a prospective series of 61 patients who underwent primary total hip arthroplasty by implantation of the HMAX-M® stem (Limacorporate, San Daniele, Italy). Serum chromium and cobalt determinations were performed at six months, two years and five years. RESULTS Our series shows a progressive elevation in chromium levels with a significant difference between chromium values at six months (0.35±0.18) and five years (0.52±0.36), P=.01. Regarding cobalt, a statistically significant elevation is observed between six months and two years and a subsequent stabilization of values between two and five years, with a cobalt mean at six months (1.17±0.8) significantly lower than at two (2.63±1.76) and five years (2.84±2.1), P=.001. CONCLUSION Elevated serum cobalt levels have been observed in patients who underwent modular neck stem implantation. The results obtained in this study have limited the use of stems with a modular neck in our clinical practice.
Collapse
Affiliation(s)
- R E López
- Hospital Universitario Doctor Peset, Valencia, España.
| | - J M Pelayo de Tomás
- Hospital Universitario Doctor Peset, Valencia, España; Facultad de Medicina, Universidad de Valencia, Valencia, España
| | - M Morales Suárez Varela
- Unidad de Salud Pública, Higiene y Sanidad Ambiental, Departamento de Medicina Preventiva, Facultad de Farmacia, Universidad de Valencia, Burjassot, Valencia, España; Consorcio de Investigación Biomédica en Red de Epidemiología y Salud Pública, Madrid, España
| | - J L Rodrigo Pérez
- Hospital Universitario Doctor Peset, Valencia, España; Facultad de Medicina, Universidad de Valencia, Valencia, España
| |
Collapse
|
3
|
López RE, Pelayo de Tomás JM, Morales Suárez Varela M, Rodrigo Pérez JL. [Translated article] Evolution of chromium and cobalt serum levels after the use of a modular neck stem in primary total hip arthroplasty. Rev Esp Cir Ortop Traumatol (Engl Ed) 2024; 68:T26-T34. [PMID: 37992863 DOI: 10.1016/j.recot.2023.11.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Accepted: 05/29/2023] [Indexed: 11/24/2023] Open
Abstract
INTRODUCTION AND OBJECTIVES Modular neck primary stems were introduced with the theoretical advantage of restoring the hip anatomy more precisely. However, the presence of a second junction has been associated with increased corrosion and release of metal debris. The objective of our study is to quantify of chromium and cobalt serum values, and to analyse their temporal evolution during five years. MATERIAL AND METHODS We present a prospective series of 61 patients who underwent primary total hip arthroplasty by implantation of the H MAX-M® stem (Limacorporate, San Daniele, Italy). Serum chromium and cobalt determinations were performed at six months, two years and five years. RESULTS Our series shows a progressive elevation in chromium levels with a significant difference between chromium values at six months (0.35±0.18) and five years (0.52±0.36), p=.01. Regarding cobalt, a statistically significant elevation is observed between six months and two years and a subsequent stabilisation of values between two and five years, with a cobalt mean at six months (1.17±0.8) significantly lower than at two (2.63±1.76) and five years (2.84±2.1), p=.001. CONCLUSION Elevated serum cobalt levels have been observed in patients who underwent modular neck stem implantation. The results obtained in this study have limited the use of stems with a modular neck in our clinical practice.
Collapse
Affiliation(s)
- R E López
- Hospital Universitario Doctor Peset, Valencia, Spain.
| | - J M Pelayo de Tomás
- Hospital Universitario Doctor Peset, Valencia, Spain; Facultad de Medicina, Universidad de Valencia, Valencia, Spain
| | - M Morales Suárez Varela
- Unidad de Salud Pública, Higiene y Sanidad Ambiental, Departamento de Medicina Preventiva, Facultad de Farmacia, Universidad de Valencia, Burjassot, Valencia, Spain; Consorcio de Investigación Biomédica en Red de Epidemiología y Salud Pública, Madrid, Spain
| | - J L Rodrigo Pérez
- Hospital Universitario Doctor Peset, Valencia, Spain; Facultad de Medicina, Universidad de Valencia, Valencia, Spain
| |
Collapse
|
4
|
Patrick M, Stromberg A, Ahn J, Hankenson K, Annamalai RT. A Murine Delayed-Healing Model Associates Immune Response with Functional Bone Regeneration after Trauma. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.10.26.564177. [PMID: 37961650 PMCID: PMC10634904 DOI: 10.1101/2023.10.26.564177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/15/2023]
Abstract
Nonunion and delayed-union fractures pose a significant clinical challenge, often leading to prolonged morbidity and impaired quality of life. Fracture-induced hematoma and acute inflammation are crucial for establishing the healing cascade. However, aberrant inflammatory phenotypes can suppress healing and cause bone resorption. Elucidating these mechanisms is necessary to develop potent immunomodulatory therapies and prevent nonunion. Here, we report a delayed fracture healing model enabling the modulation of interfragmentary strain that mimics the etiology of hypertrophic nonunions to elucidate the role of dysregulated immune response in poor healing outcomes. High interfragmentary strain (>15%) was associated with larger callus volumes but delayed bone healing, increased inflammation, and inferior healing outcomes, while lower strain levels (<5%) corresponded to normal bone healing. In addition, we found distinct differences in the ossification, chondrification, and fibrosis patterns between high and low-strain groups, underscoring the significant impact of strain on the healing process. A comprehensive analysis of the systemic immune response revealed dynamic alterations in immune cell populations and factors, particularly within the early hours and days post-fracture. Several immune factors exhibited significant correlations with various functional healing outcomes, indicating their potential as predictive markers for assessing fracture healing progression. Our results also highlighted the significance of timely resolution of proinflammatory signals and the elevation of pro-regenerative immune cell phenotypes in promoting bone regeneration. Multivariate analysis revealed that CD25+ T-regulatory cells were influential in predicting proper bone healing, followed by CD206+ macrophages, underscoring the pivotal role of immune cell populations in the bone healing process. In conclusion, our study provides valuable insights into the intricate interplay between interfragmentary strain, immune response, and the ultimate outcomes of fracture healing. By shedding light on the underlying mechanisms that drive hypertrophic nonunion pathogenesis, our research lays the foundation for enhanced surgical management of nonunions and offers a promising avenue for developing targeted therapeutic interventions and personalized treatment strategies for individuals suffering from fracture nonunion.
Collapse
|
5
|
Palazzuolo M, Bensa A, Bauer S, Blakeney WG, Filardo G, Riegger M. Resurfacing Hip Arthroplasty Is a Safe and Effective Alternative to Total Hip Arthroplasty in Young Patients: A Systematic Review and Meta-Analysis. J Clin Med 2023; 12:jcm12062093. [PMID: 36983096 PMCID: PMC10052473 DOI: 10.3390/jcm12062093] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2023] [Revised: 03/02/2023] [Accepted: 03/04/2023] [Indexed: 03/30/2023] Open
Abstract
This systematic review and meta-analysis of randomized controlled trials (RCTs) aimed at comparing resurfacing hip arthroplasty (RHA) and total hip arthroplasty (THA) in terms of rate of complications, revisions, functional outcomes, blood loss, operative time and metal ions levels. The search was conducted on three databases (PubMed, Cochrane and Web of Science) updated until 13 October 2022. The inclusion criteria were RCTs) written in the English language, with no time limitation, comparing RHA and THA. Among the retrieved 4748 articles, 18 RCTs were eligible for a total of 776 patients (mean age 53.1 ± 5.0). A meta-analysis was performed. RHA reported significantly lower blood loss compared to THA (p < 0.001) but with longer operative time (p < 0.001). No statistically significant difference was found between RHA and THA in terms of complications (12.08% and 16.24%, respectively) and revisions (6.32% and 6.14%, respectively). Both RHA and THA provide excellent clinical results in a population of young and active patients. Functional outcomes were not significantly different between the groups. Moreover, no significant difference in metal ion levels was found. These findings provide evidence concerning the safety and clinical effectiveness of RHA. Because of its bone-preserving properties, the lack of drawbacks and good outcomes, RHA appears to be a valid alternative to THA in young and active patients.
Collapse
Affiliation(s)
- Michele Palazzuolo
- Service of Orthopaedics and Traumatology, Department of Surgery, EOC, 6600 Locarno, Switzerland
| | - Alessandro Bensa
- Service of Orthopaedics and Traumatology, Department of Surgery, EOC, 6900 Lugano, Switzerland
| | - Stefan Bauer
- Service d'Orthopédie et de Traumatologie, Chirurgie de l'Épaule, Ensemble Hospitalier de la Côte, 1110 Morges, Switzerland
- Department of Orthopedic Surgery, Royal Perth Hospital, Perth, WA 6000, Australia
| | - William G Blakeney
- Department of Orthopedic Surgery, Royal Perth Hospital, Perth, WA 6000, Australia
| | - Giuseppe Filardo
- Service of Orthopaedics and Traumatology, Department of Surgery, EOC, 6900 Lugano, Switzerland
- Faculty of Biomedical Sciences, Università della Svizzera Italiana, 6900 Lugano, Switzerland
| | - Martin Riegger
- Service of Orthopaedics and Traumatology, Department of Surgery, EOC, 6900 Lugano, Switzerland
- Faculty of Biomedical Sciences, Università della Svizzera Italiana, 6900 Lugano, Switzerland
| |
Collapse
|
6
|
Tognini M, Hothi H, Tucker S, Broomfield E, Shafafy M, Gikas P, Di Laura A, Henckel J, Hart A. Blood titanium levels in patients with large and sliding titanium implants. BMC Musculoskelet Disord 2022; 23:783. [PMID: 35974363 PMCID: PMC9380337 DOI: 10.1186/s12891-022-05717-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Accepted: 07/29/2022] [Indexed: 11/23/2022] Open
Abstract
Background Titanium, which is known to be a highly biologically inert element, is one of the most commonly used metals in orthopaedic implants. While cobalt and chromium blood metal ion testing is routinely used in the clinical monitoring of patients with metal-on-metal hip implants, much less is known about the levels of titanium in patients with other implant types. The aim of this study was to better understand the normal ranges of blood titanium levels in patients implanted with large and sliding titanium constructs by comparison with reference levels from conventional titanium hips. Methods This study examined data collected from 136 patients. Over a period of 24 months, whole blood samples were collected from 41 patients implanted with large titanium implants: long (range 15 to 30 cm) spine rods with a sliding mechanism (“spine rods”, n = 18), long bone tumour implants (“tumour implants”, n = 13) and 3D-printed customised massive acetabular defect implants (“massive acetabular implants”, n = 10). This data was compared with standard, uncemented primary titanium hip implants (“standard hips”, 15 cm long) (n = 95). Clinical, imaging and blood titanium levels data were collected for all patients and compared statistically between the different groups. Results The median (range) of blood titanium levels of the standard hip, spine rods, femoral tumour implants and massive acetabular implants were 1.2 ppb (0.6–4.9), 9.7 ppb (4.0–25.4), 2.6 ppb (0.4–104.4) and 5.7 ppb (1.6–31.5) respectively. Spine rods and massive acetabular implants had significantly greater blood titanium levels compared to the standard hips group (p < 0.001). Conclusion This study showed that titanium orthopaedic implants that are large and/or have a sliding mechanism have higher blood titanium levels compared to well-functioning, conventionally sized titanium hips. Reassuringly, the increased levels did not appear to induce adverse metal reactions. This study provides useful baseline data for future studies aimed at assessing blood titanium levels as a biomarker for implant function.
Collapse
Affiliation(s)
- Martina Tognini
- Institute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, HA7 4LP, UK.
| | - Harry Hothi
- Institute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, HA7 4LP, UK
| | - Stewart Tucker
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
| | - Edel Broomfield
- Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK
| | - Masood Shafafy
- Department of Trauma and Orthopaedics, Nottingham University Hospitals NHS Trust, Nottingham, UK
| | - Panos Gikas
- Institute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, HA7 4LP, UK
| | - Anna Di Laura
- Institute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, HA7 4LP, UK
| | - Johann Henckel
- Institute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, HA7 4LP, UK
| | - Alister Hart
- Institute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, HA7 4LP, UK
| |
Collapse
|
7
|
Eichler D, Barry J, Lavigne M, Massé V, Vendittoli PA. No radiological and biological sign of trunnionosis with Large Diameter Head Ceramic Bearing Total Hip Arthroplasty after 5 years. Orthop Traumatol Surg Res 2021; 107:102543. [PMID: 32276843 DOI: 10.1016/j.otsr.2019.12.015] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2019] [Revised: 12/18/2019] [Accepted: 12/23/2019] [Indexed: 02/06/2023]
Abstract
BACKGROUND Trunnionosis of large diameter (LDH) metal-on-metal total hip arthroplasty (THA) was linked to high systemic chromium (Cr) and cobalt (Co) ion levels and local adverse reactions to metal debris (ARMD). The safety of CoC LDH THA is not yet available at mid-term. Measuring whole blood Ti level of ceramic on ceramic (CoC) LDH THA with a titanium (Ti) stem is an indirect way to assess the performance of its head-neck taper modular junction. Therefore, we wanted to determine: (1) if the whole blood Ti ion levels in patients with LDH CoC THA after a minimum of 5 years of implantation is within the expected values for similar well performing Ti THA, (2) if Ti level scientifically increases over time, which would suggest the presence of a progressive modular head/neck junction wear process, (3) if clinical or radiographical manifestations of implant dysfunction are present? HYPOTHESIS Ti blood levels of LDH CoC THA will indirectly reflect the expected levels due to passive corrosion of the implants and will be stable over time. PATIENTS AND METHODS We report the whole blood Ti, Cr, and Co levels at 5years minimum for 57 patients with unilateral primary LDH CoC THA with head sizes ranging from 36 to 48mm using Ti stem and acetabular component. To compare Ti ion levels modification over time, in 25 patients were a previous measurement (1-3years) was available, we compared it to their last follow-up results (>5 years). Mean Ti level in well performing Ti THAs is recognized to be around 2.0 ug/L. Although, there are no universally accepted Ti levels associated with problematic implant, we used safety threshold of 10 ug/L. Clinical and radiological outcomes were recorded at last follow-up. RESULTS At 79 months mean follow-up, all mean Ti levels were 1.9μg/L (min 1.2, max 4.4) and all subject had values below the safety threshold of 10ug/L. In the subgroup of 25 cases with a previous measurement, there was a decrease in mean Ti levels between 20 months and 78 months follow-up (2.2μg/L (1.6-3.9) versus 2.0μg/L (1.4-2.8), p=0.007). No statistically significant relation was observed between Ti level at last FU and bearing diameter (rho=0.046, p=0.0734) or the presence or absence of a Ti adaptor sleeve (p=0.454): 1.94ug/L (min 1.20, max 2.80) versus 1.90ug/L (min 1.20, max 4.40). At last follow up, no patients presented osteolysis signs on radiographs, clinical signs of ARMD or were reoperated. Most patients had excellent clinical with 98% of them reporting minor (29%) or no functional limitation (69%) and 44% perceive their THA as a natural hip joint. However, 3/57patients (5%) temporarily experienced hip squeaking and 18/57 (31%) reported clicking sound. CONCLUSION With the tested LDH CoC THA, Ti levels were low and related the uneventful and unavoidable passive corrosion of implant surfaces. Mid-term measurement of Ti in subjects with LDH CoC did not reveal any indirect signs of trunnionosis, which should already be observable by this time. LEVEL OF EVIDENCE IV, retrospective study.
Collapse
Affiliation(s)
- David Eichler
- Université de Montréal, Hôpital Maisonneuve-Rosemont, Department of Surgery, 5415, boulevard de l'Assomption, Montréal, QC H1T2M4, Canada
| | - Janie Barry
- Université de Montréal, Hôpital Maisonneuve-Rosemont, Department of Surgery, 5415, boulevard de l'Assomption, Montréal, QC H1T2M4, Canada
| | - Martin Lavigne
- Université de Montréal, Hôpital Maisonneuve-Rosemont, Department of Surgery, 5415, boulevard de l'Assomption, Montréal, QC H1T2M4, Canada
| | - Vincent Massé
- Université de Montréal, Hôpital Maisonneuve-Rosemont, Department of Surgery, 5415, boulevard de l'Assomption, Montréal, QC H1T2M4, Canada
| | - Pascal-André Vendittoli
- Université de Montréal, Hôpital Maisonneuve-Rosemont, Department of Surgery, 5415, boulevard de l'Assomption, Montréal, QC H1T2M4, Canada.
| |
Collapse
|
8
|
Dias Corpa Tardelli J, Bolfarini C, Cândido Dos Reis A. Comparative analysis of corrosion resistance between beta titanium and Ti-6Al-4V alloys: A systematic review. J Trace Elem Med Biol 2020; 62:126618. [PMID: 32663743 DOI: 10.1016/j.jtemb.2020.126618] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2020] [Revised: 06/19/2020] [Accepted: 07/08/2020] [Indexed: 01/20/2023]
Abstract
BACKGROUND The knowledge of the electrochemical property (corrosion resistance) of beta titanium alloys compared to Ti-6Al-4 V for implants is relevant because of the potential cytotoxic effects that the released ions could cause to long-term health. OBJECTIVES The objective of this systematic review was to seek information on the electrochemical properties (corrosion resistance) of beta titanium alloys compared to Ti-6Al-4 V since the awareness of the electrochemical behavior of the implant surface in the medium is essential for the best indication of the alloys or compositional changes, which may promote benefits to bone-implant interaction in all areas that this procedure is required. METHODS The PubMed, LILACS, COCHRANE Library, and Science Direct databases were electronically searched for the terms: dental implants AND beta-titanium AND Ti-6Al-4 V AND electrochemical technics. The inclusion criteria were research articles that studied beta-titanium compared to Ti-6Al-4 V using electrochemical techniques in electrolytes of chemical composition similar to body fluid, published in English, between 2000 and 2020. Articles that did not compare the corrosion resistance of these alloys in electrolytes similar to body fluids were excluded. RESULTS A total of 189 articles were restored and selected by title and/or abstract according to the inclusion and exclusion criteria, which resulted in 15 articles that were reduced to 8 after read in full. The studies in vitro evaluated the corrosion resistance in electrolytes Hank, Ringer, SBF, and 0.9 % NaCl, between beta titanium alloys, obtained by arc fusion or bars stock, and Ti-6Al-4 V, for dental or biomedical implants submitted to surface treatments by heat treatment, plasma electrolytic oxidation (PEO), alkaline treatment, and thermomechanical. CONCLUSION The evaluated literature allowed to determine that 1) The oxides Nb2O 5, Ta2O 5, and ZrO2 have higher stability and protection quality than that of TiO2 modified by the oxides of Al and V; 2) A higher modulus of elasticity of the Ti-6Al-4 V alloy favors protection against corrosion by maintaining a thicker and more firmly adhered oxide layer; 3) The increase in the thickness of the Ti alloys superficial layer contributes to the improvement of the corrosion resistance.
Collapse
Affiliation(s)
- Juliana Dias Corpa Tardelli
- Department of Dental Materials and Prosthesis, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, SP, Brazil.
| | - Claudemiro Bolfarini
- Department of Materials Engineering, Federal University of São Carlos (UFSCAR), São Carlos, SP, Brazil.
| | - Andréa Cândido Dos Reis
- Department of Dental Materials and Prosthesis, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, SP, Brazil.
| |
Collapse
|
9
|
Vendittoli PA, Shahin M, Rivière C, Roy AG, Barry J, Lavigne M. Hip Resurfacing Compared with 28-mm Metal-on-Metal Total Hip Replacement: A Randomized Study with 15 Years of Follow-up. J Bone Joint Surg Am 2020; 102:80-90. [PMID: 32554999 DOI: 10.2106/jbjs.20.00030] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Bone stock conservation, hip anatomy preservation, and greater stability are among the promoted advantages of hip resurfacing (HR). However, the disappointing failure of some implants nearly led to its abandonment. The aim of this study was to compare clinical scores and revision and complication rates after HR with those after total hip arthroplasty (THA). METHODS Two hundred and three hips were randomized to 28-mm metal-on-metal (MoM) THA (99 hips) or to HR (104 hips). Main outcome measures compared between groups were the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, the revision rate, and the complication rates. The radiographic findings were also assessed. RESULTS After a mean follow-up of 15 years (range, 14 to 16 years), 9 (4.4%) of the 203 patients were lost to follow-up and 15 (7.4%) had died. The Kaplan-Meier survivorship, with revision for any reason as the end point, was 89.2% (95% confidence interval [CI], 82.3% to 96.1%) for HR and 94.2% (95% CI, 89.3% to 99.1%) for THA (p = 0.292). The reasons for revision included infection (3 patients), recurrent dislocation (1 patient), and adverse reaction to metal debris (ARMD) (1 patient) in the THA group and ARMD (2 patients) and femoral head loosening (7 patients) in the HR group. With aseptic revision as the end point, the Kaplan-Meier survivorship was significantly higher in the THA group (97.4% versus 89.2%; p = 0.033). No dislocation occurred in the HR group compared with 4 in the THA group (p = 0.058). Both groups achieved a similar mean WOMAC score (10.7 in the HR group and 8.8 in the THA group; p = 0.749), Forgotten Joint Score (87.1 and 85.3, respectively; p = 0.410), University of California Los Angeles (UCLA) activity score (6.3 and 6.4, respectively; p = 0.189), and overall joint perception (p = 0.251). CONCLUSIONS The specific HR and MoM 28-mm THA implants used in this study showed good long-term survival and function. The overall rates of complications and revisions were similar in both groups but were of different types. As it provides better femoral bone preservation and biomechanical reconstruction, HR may continue to have a role in selected patients when performed by experienced surgeons and using validated implants. LEVEL OF EVIDENCE Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Pascal-André Vendittoli
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montréal, Québec, Canada
| | - Maged Shahin
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montréal, Québec, Canada
| | | | - Alain Guy Roy
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montréal, Québec, Canada
| | - Janie Barry
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montréal, Québec, Canada
| | - Martin Lavigne
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montréal, Québec, Canada
| |
Collapse
|
10
|
Mihalko WM, Haider H, Kurtz S, Marcolongo M, Urish K. New materials for hip and knee joint replacement: What's hip and what's in kneed? J Orthop Res 2020; 38:1436-1444. [PMID: 32437026 DOI: 10.1002/jor.24750] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2019] [Revised: 04/24/2020] [Accepted: 05/01/2020] [Indexed: 02/04/2023]
Abstract
Over the last three decades there have been significant advancements in the knee and hip replacement technology that has been driven by an issue in the past concerning adverse local tissue reactions, aseptic and septic loosening. The implants and the materials we utilize have improved over the last two decades and in knee and hip replacement there has been a decrease in the failures attributed to wear and osteolysis. Despite these advancements there are still issues with patient satisfaction and early revisions due to septic and aseptic loosening in knee replacement patients. This article reviews the state of current implant material technology in hip and knee replacement surgery, discusses some of the unmet needs we have in biomaterials, and reviews some of the current biomaterials and technology that may be able to solve the most common issues in the knee and hip replacement surgery.
Collapse
Affiliation(s)
- William M Mihalko
- Department of Orthopaedic Surgery and Biomedical Engineering, Campbell Clinic Department of Orthopaedic Surgery and Biomedical Engineering, University of Tennessee Health Science Center, Memphis, Tennessee
| | - Hani Haider
- Orthopaedic Biomechanics and Advanced Surgical Technologies Laboratory, Department of Orthopaedic Surgery and Rehabilitation, University of Nebraska Medical Center, Omaha, Nebraska
| | - Steven Kurtz
- Exponent Inc., Drexel University, Philadelphia, Pennsylvania
| | - Michele Marcolongo
- Department of Materials Science and Engineering, Drexel University, Philadelphia, Pennsylvania
| | - Kenneth Urish
- Department of Orthopaedic Surgery, Clinical and Translational Science Institute, University of Pittsburgh, Pittsburgh, Pennsylvania.,Department of Bioengineering, Clinical and Translational Science Institute, University of Pittsburgh, Pittsburgh, Pennsylvania.,Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania
| |
Collapse
|
11
|
Tanoğlu O, Say F, Yücens M, Alemdaroğlu KB, İltar S, Aydoğan NH. Titanium Alloy Intramedullary Nails and Plates Affect Serum Metal Ion Levels within the Fracture Healing Period. Biol Trace Elem Res 2020; 196:60-65. [PMID: 31621008 DOI: 10.1007/s12011-019-01913-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/24/2019] [Accepted: 09/20/2019] [Indexed: 11/28/2022]
Abstract
Titanium alloy implants are the most used materials for the fixation of lower extremity fractures. Although these implants were thought to be inert materials in vitro, several studies have shown increased serum and remote tissue metal ion levels due to wear of implants and friction of the bone-implant interface in vivo. The aim of this study was to investigate the alteration of serum metal ion levels that are released from intramedullary nails and plates used for the fixation of lower extremity fractures, within the fracture healing period. The study included 20 adult patients, who were treated with intramedullary nail or plate osteosynthesis due to closed lower extremity fractures. Alterations of serum titanium, aluminum, molybdenum, and vanadium levels were evaluated at 6, 12, 18, and 24 weeks postoperatively. A statistically significant increase was determined in serum titanium, aluminum, molybdenum, and vanadium ion levels in the intramedullary nail and plate groups at the end of the follow-up period. Pairwise comparisons of metal ion levels between implant groups revealed no significant difference during a 24-week follow-up period. Compared to the control group, statistically significant increased levels of serum titanium, aluminum, vanadium, and molybdenum ions were determined in the implant groups used for the fixation of lower extremity fractures at the end of 24 weeks. In the current literature, the potential toxic effects of prolonged exposure to low levels of these metal ions are still unknown. It can be predicted that long-term metal ion exposure could result in vivo pathological processes in the future.
Collapse
Affiliation(s)
- Oğuzhan Tanoğlu
- Faculty of Medicine, Department of Orthopedics and Traumatology, Erzincan Binali Yıldırım University, Erzincan, Turkey.
| | - Ferhat Say
- Faculty of Medicine, Department of Orthopedics and Traumatology, Ondokuz Mayıs University, Samsun, Turkey
| | - Mehmet Yücens
- Faculty of Medicine, Department of Orthopedics and Traumatology, Pamukkale University, Denizli, Turkey
| | - Kadir Bahadır Alemdaroğlu
- Department of Orthopedics and Traumatology, SBU Ankara Research and Training Hospital, Ankara, Turkey
| | - Serkan İltar
- Department of Orthopedics and Traumatology, SBU Ankara Research and Training Hospital, Ankara, Turkey
| | - Nevres Hürriyet Aydoğan
- Faculty of Medicine, Department of Orthopedics and Traumatology, Muğla Sıtkı Koçman University, Muğla, Turkey
| |
Collapse
|
12
|
Kwon YM. Adverse Local Tissue Reactions in Total Hip Arthroplasty: Who, When, and How to Revise. J Arthroplasty 2020; 35:S53-S54. [PMID: 31973968 DOI: 10.1016/j.arth.2019.12.042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Accepted: 12/29/2019] [Indexed: 02/01/2023] Open
Affiliation(s)
- Young-Min Kwon
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| |
Collapse
|
13
|
Swiatkowska I, Martin NG, Henckel J, Apthorp H, Hamshere J, Hart AJ. Blood and plasma titanium levels associated with well-functioning hip implants. J Trace Elem Med Biol 2020; 57:9-17. [PMID: 31546210 DOI: 10.1016/j.jtemb.2019.09.005] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/25/2019] [Revised: 08/28/2019] [Accepted: 09/13/2019] [Indexed: 01/13/2023]
Abstract
BACKGROUND Hip implants are usually manufactured from cobalt-chromium and titanium alloys. As the implants wear and corrode, metal debris is released into the surrounding tissue and blood, providing a potential biomarker for their function. Whilst there are laboratory reference levels for blood cobalt and chromium in patients with well and poorly functioning hip implants, there are no such guidelines for titanium. This is despite the increasing use of titanium implants worldwide. PATIENTS AND METHODS We recruited a consecutive series of 95 patients (mean age 71 years, mean time after surgery 8.5 years) with one hip implant type, inserted by the same surgeon. We assessed clinical and radiological outcome, and measured blood and plasma titanium using high resolution inductively-coupled plasma mass spectrometry. RESULTS The upper normal reference limit for blood and plasma titanium was 2.20 and 2.56 μg L-1, respectively, and did not differ significantly between males and females. CONCLUSION We are the first to propose a laboratory reference level for blood and plasma titanium in patients with well-functioning titanium hip implants. This is an essential starting point for further studies to explore the clinical usefulness of blood titanium as a biomarker of orthopaedic implant performance, and comes at a time of considerable controversy regarding the use of certain titanium alloys in hip arthroplasty.
Collapse
Affiliation(s)
- Ilona Swiatkowska
- Institute of Orthopaedics and Musculoskeletal Science, University College London, HA7 4LP Stanmore, UK.
| | - Nicholas G Martin
- Trace Element Laboratory, North West London Pathology, Charing Cross Hospital, W6 8RF London, UK
| | - Johann Henckel
- Royal National Orthopaedic Hospital, Stanmore, HA7 4LP Stanmore, UK
| | | | | | - Alister J Hart
- Institute of Orthopaedics and Musculoskeletal Science, University College London, HA7 4LP Stanmore, UK; Royal National Orthopaedic Hospital, Stanmore, HA7 4LP Stanmore, UK
| |
Collapse
|
14
|
Murena L, Maritan G, Concina C, Scamacca V, Ratti C, Canton G. Fracture of Cobalt-Crome Modular Neck in Total Hip Arthroplasty. ACTA BIO-MEDICA : ATENEI PARMENSIS 2019; 90:187-191. [PMID: 31821307 PMCID: PMC7233721 DOI: 10.23750/abm.v90i12-s.8941] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2019] [Accepted: 10/25/2019] [Indexed: 02/08/2023]
Abstract
Despite the advantages of modular total hip arthroplasty in terms of neck version, offset and length precise reproduction, titanium necks breakage became a concern. Consequently, titanium has been replaced by cobalt-chrome (Co-Cr). However, four cases of Co-Cr modular neck breakage have been reported in the literature. In the present paper, two cases of Co-Cr modular neck fractures are described together with a literature review. The aim of this work is to discuss the risk factors and characteristics of this rare complication. We described two cases of fracture of long varus Co-Cr modular femoral neck connected with cementless press-fit stem. Some risk factors, such as long varus type of modular neck, overweight and/or high demanding physical activity, might have contributed to implant failure.
Collapse
Affiliation(s)
- Luigi Murena
- Orthopaedics and Traumatology Unit, Cattinara Hospital - ASUITS, Strada di Fiume 447, 34149 Trieste (Italy).
| | | | | | | | | | | |
Collapse
|
15
|
Ridon PE, Putman S, Migaud H, Berton C, Pasquier G, Girard J. Long-term comparative study of large-diameter metal-on-metal bearings: Resurfacing versus total arthroplasty with large-diameter Durom™ bearing. Orthop Traumatol Surg Res 2019; 105:943-948. [PMID: 31196833 DOI: 10.1016/j.otsr.2019.04.006] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/08/2018] [Revised: 04/09/2019] [Accepted: 04/16/2019] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Short-term results in total hip arthroplasty (THA) with large-diameter metal-on-metal (MoM) bearings were encouraging, but high failure rates have been reported in the long term, notably implicating corrosion due to modularity. Several studies compared resurfacing (to which modularity does not apply) versus large-diameter MoM THA; but, to our knowledge, none compared the same bearing in the two situations with more than 10 years' follow-up. We therefore conducted a retrospective case-control study, using a single cup model (Durom™, Zimmer, Warsaw, USA) for both resurfacing (R) and large-diameter THA, to determine the role of modularity in failure of large-diameter MoM bearings. The study compared (1) metallic ion levels, and (2) survival, functional scores and complications rates between R and THA. HYPOTHESIS Large-diameter MoM bearing failure implicates not bearing wear but head-neck junction modularity in larger-diameter MoM THA. MATERIAL AND METHOD Eighty-three THAs and 90 Rs were included between February 2004 and March 2006. All patients had clinical and radiologic follow-up with chromium (Cr) and cobalt (Co) ion blood assay. RESULTS In the THA group, 24 of the 83 patients (28.9%) underwent revision for adverse reaction to metal debris (ARMD), versus none in the R group. Ten-year all-cause survival was significantly better in R (97.7%; 95% CI, 96.2-99.2) than THA (67.1%; 95% CI, 60.9-73.3). Median blood ion level was higher in THA (with a difference between Co and Cr: 5.75μg/L (range, 3.82-19.2) versus 1.75μg/L (range, 1.34-2.94) respectively) than in R (no difference: 0.89μg/L (range, 0.67-2.89) and 1.07μg/L (range, 0.67-1.65) respectively). In the THA group, there were positive correlations between Co and Cr elevation and implant revision (both p<0.0001). Co/Cr ratio was significantly higher in THA (2.57) than R (0.88) (p<0.0001), and higher again in the 24 cases of THA revision (4.67). There was no significant difference in mean PMA score (THA: 17.08±1.82 (range, 7-18); R: 17.50±0.74 (range, 15-18)), whereas mean Oxford score was better in R (14.32±2.5 (range, 12-24)) than THA (18.17±8.05 (range, 12-42)) (p=0.02). DISCUSSION The present study confirmed the incontrovertible implication of modularity in failure of large-diameter MoM THA, by analyzing the same bearing in THA and in resurfacing. Trunnionosis was observed in the 24 cases of revision, with the THA adaptation ring inducing serious metallic ion release (with dissociated Co/Cr ratio), accounting for the high rate of revision. LEVEL OF EVIDENCE III, case-control study.
Collapse
Affiliation(s)
- Pierre-Emmanuel Ridon
- Université de Lille Nord de France, 59000 Lille, France; Service d'orthopédie, hôpital Roger-Salengro, Centre Hospitalier et Universitaire de Lille, place de Verdun, 59037 Lille, France.
| | - Sophie Putman
- Université de Lille Nord de France, 59000 Lille, France; Service d'orthopédie, hôpital Roger-Salengro, Centre Hospitalier et Universitaire de Lille, place de Verdun, 59037 Lille, France
| | - Henri Migaud
- Université de Lille Nord de France, 59000 Lille, France; Service d'orthopédie, hôpital Roger-Salengro, Centre Hospitalier et Universitaire de Lille, place de Verdun, 59037 Lille, France
| | - Charles Berton
- Service Traumatologie B, hôpital Jean-Bernard, Centre Hospitalier de Valenciennes, 114, avenue Desandrouin, 59322 Valenciennes, France
| | - Gilles Pasquier
- Université de Lille Nord de France, 59000 Lille, France; Service d'orthopédie, hôpital Roger-Salengro, Centre Hospitalier et Universitaire de Lille, place de Verdun, 59037 Lille, France
| | - Julien Girard
- Université de Lille Nord de France, 59000 Lille, France; Service d'orthopédie, hôpital Roger-Salengro, Centre Hospitalier et Universitaire de Lille, place de Verdun, 59037 Lille, France
| |
Collapse
|
16
|
Bang LT, Filho LC, Engqvist H, Xia W, Persson C. Synthesis and assessment of metallic ion migration through a novel calcium carbonate coating for biomedical implants. J Biomed Mater Res B Appl Biomater 2019; 108:429-438. [PMID: 31058422 DOI: 10.1002/jbm.b.34399] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2018] [Revised: 04/13/2019] [Accepted: 04/15/2019] [Indexed: 11/07/2022]
Abstract
Titanium (Ti) implants are commonly regarded as well accepted by the body. However, metal ion release is still a cause for concern. A small decrease in pH, which can be caused by inflammation, may produce a large increase in the corrosion rate of Ti implants. Coating the alloy with a buffer layer could have a significant protective effect. In this study, a calcium carbonate coating was developed on commercially pure Ti and a Ti-6Al-4V alloy through a hydrothermal treatment of previously NaOH-treated surfaces in calcium-citric acid chelate complexes. The results showed that a superstructured calcite coating layer formed on the Ti substrate after treatment at 170°C for 3 hr. The coating was approx. 1 μm thick and covered the substrate surface uniformly. When prolonging the hydrothermal treatment from 5 hr to 24 hr, the rhombohedral structure of calcite was observed in addition to the superstructure of calcite. Dissolution test results showed no significant differences in solution pH between the coated- and un-coated samples. However, the CaCO3 coating reduced by approx. 2-5 times the Ti and V ion release from the substrate as compared to the uncoated material, at pH 4. CaCO3 and hydroxyapatite (HA) coatings gave nonsignificant effects at neutral pH although the HA coating showed a trend for better results at the longer time points. The reduction in metal ion release from the substrate and the buffering ability of the CaCO3 coating encourage further studies on this coating for clinical applications.
Collapse
Affiliation(s)
- Le Thi Bang
- Division of Applied Materials Science, Department of Engineering Sciences, Uppsala University, Uppsala, Sweden
| | - Luimar C Filho
- Division of Applied Materials Science, Department of Engineering Sciences, Uppsala University, Uppsala, Sweden
| | - Håkan Engqvist
- Division of Applied Materials Science, Department of Engineering Sciences, Uppsala University, Uppsala, Sweden
| | - Wei Xia
- Division of Applied Materials Science, Department of Engineering Sciences, Uppsala University, Uppsala, Sweden
| | - Cecilia Persson
- Division of Applied Materials Science, Department of Engineering Sciences, Uppsala University, Uppsala, Sweden
| |
Collapse
|
17
|
Swiatkowska I, Martin N, Hart AJ. Blood titanium level as a biomarker of orthopaedic implant wear. J Trace Elem Med Biol 2019; 53:120-128. [PMID: 30910194 DOI: 10.1016/j.jtemb.2019.02.013] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/26/2018] [Revised: 02/18/2019] [Accepted: 02/27/2019] [Indexed: 12/12/2022]
Abstract
BACKGROUND Joint replacement implants are usually manufactured from cobalt-chromium or titanium alloys. After the device is implanted, wear and corrosion generate metal particles and ions, which are released into local tissue and blood. The metal debris can cause a range of adverse local and systemic effects in patients. RESEARCH PROBLEM In the case of cobalt and chromium, a blood level exceeding 7 μg L-1 indicates potential for local toxicity, and a failing implant. It has been repeatedly suggested in the literature that measurement of titanium could also be used to assess implant function. Despite an increasing interest in this biomarker, and growing use of titanium in orthopaedics, it is unclear what blood concentrations should raise concerns. This is partly due to the technical challenges involved in the measurement of titanium in biological samples. AIM This Review summarises blood/serum titanium levels associated with well-functioning and malfunctioning prostheses, so that the prospects of using titanium measurements to gain insights into implant performance can be evaluated. CONCLUSION Due to inter-laboratory analytical differences, reliable conclusions regarding "normal" and "abnormal" titanium levels in patients with orthopaedic implants are difficult to draw. Diagnosis of symptomatic patients should be based on radiographic evidence combined with blood/serum metal levels.
Collapse
Affiliation(s)
- Ilona Swiatkowska
- Institute of Orthopaedics and Musculoskeletal Science, University College London, HA7 4LP, Stanmore, UK.
| | - Nicholas Martin
- Trace Element Laboratory, Clinical Biochemistry, Charing Cross Hospital, W6 8RF, London, UK
| | - Alister J Hart
- Institute of Orthopaedics and Musculoskeletal Science, University College London, HA7 4LP, Stanmore, UK; Royal National Orthopaedic Hospital, Stanmore, HA7 4LP, UK
| |
Collapse
|
18
|
Eethakota VVS, Vaishnav V, Johnston L, Abboud R, Wang W. Comparison of revision risks and complication rates between total HIP replacement and HIP resurfacing within the similar age group. Surgeon 2018; 16:339-349. [PMID: 29907524 DOI: 10.1016/j.surge.2018.05.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2018] [Revised: 05/04/2018] [Accepted: 05/20/2018] [Indexed: 11/29/2022]
Abstract
BACKGROUND AND PURPOSE Currently it is not clear whether age is a factor affecting revisions in total hip replacement (THR) and hip resurfacing (HR). This study aimed to investigate which of THR or HR has a higher risk in terms of revision and complication within similar age groups. METHODS A systemic review was performed for published literature research databases and local data and compared the two procedures under the condition that both groups of patients were age matched. Meta-analysis techniques were used to analyse revision and complication rates. Twenty-seven literature studies were included along with local audit data. In total, 2520 HR procedures were compared with age-matched 2526 of THR procedures. MAIN FINDINGS It was found that revision risk of HR is significantly higher than THR (risk ratio 1.65, 95% CI 1.28-2.31, p < 0.0001), highlighting that HR has a slightly higher chance of reoperation when compared to THR within the similar age group population. In terms of complications, HR was found to have an advantage over THR (risk ratio 0.84, 95% CI 0.73-0.96, p < 0.01). CONCLUSION THR had a lower revision risk but a slightly higher complication risk than HR under the condition that the two surgical procedures were applied to similar age groups of patients. In other words, age has not played an important role in revision and complication. Survivorship cannot be measured as follow-up periods were different in the studies used.
Collapse
Affiliation(s)
| | - Vinod Vaishnav
- Department of Orthopaedic and Trauma Surgery, Ninewells Hospital and Medical School, TORT Centre, University of Dundee, Dundee, UK
| | - Linda Johnston
- Department of Orthopaedic and Trauma Surgery, Ninewells Hospital and Medical School, TORT Centre, University of Dundee, Dundee, UK
| | - Rami Abboud
- Department of Orthopaedic and Trauma Surgery, Ninewells Hospital and Medical School, TORT Centre, University of Dundee, Dundee, UK
| | - Weijie Wang
- Department of Orthopaedic and Trauma Surgery, Ninewells Hospital and Medical School, TORT Centre, University of Dundee, Dundee, UK.
| |
Collapse
|
19
|
Costa ML, Griffin XL, Parsons N, Dritsaki M, Perry D. Efficacy versus effectiveness in clinical trials. Bone Joint J 2018; 99-B:419-420. [PMID: 28385928 DOI: 10.1302/0301-620x.99b4.bjj-2016-1247] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2016] [Accepted: 12/15/2016] [Indexed: 11/05/2022]
Affiliation(s)
- M L Costa
- University of Oxford, John Radcliffe Hospital, Oxford, OX3 7UD, UK
| | - X L Griffin
- University of Oxford, John Radcliffe Hospital, Oxford, OX3 7UD, UK
| | - N Parsons
- University of Warwick, Warwick Medical School, Coventry, CV4 7AL, UK
| | - M Dritsaki
- University of Oxford, Oxford, OX3 7HE, UK
| | - D Perry
- University of Liverpool, Easton Rd, Liverpool, L12 2AP, UK
| | | |
Collapse
|
20
|
Lehtovirta L, Reito A, Parkkinen J, Peräniemi S, Vepsäläinen J, Eskelinen A. Association between periprosthetic tissue metal content, whole blood and synovial fluid metal ion levels and histopathological findings in patients with failed metal-on-metal hip replacement. PLoS One 2018; 13:e0197614. [PMID: 29768492 PMCID: PMC5955572 DOI: 10.1371/journal.pone.0197614] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2017] [Accepted: 05/04/2018] [Indexed: 02/08/2023] Open
Abstract
Adverse Reaction to Metal Debris (ARMD) is a major cause of implant failure leading to revision surgery in patients with metal-on-metal (MoM) hip arthroplasties. However, the pathogenesis and its association to implant wear are poorly understood and previous studies have yielded discrepant results. We sought to investigate the associations between histological findings, whole blood and synovial fluid metal ion concentrations and periprosthetic tissue metal concentrations in patients with MoM total hip replacements and hip resurfacings revised for ARMD. 107 hips in total were included in our study. Of these, 87 were total hip replacements and 20 were hip resurfacings, respectively. We found that whole blood, synovial fluid and periprosthetic tissue metal concentrations correlated poorly with histological findings. We suggest that the lack of a clear association between histological findings and wear measures in the present study as well as in previous studies is mostly influenced by variability in patient susceptibility. However, patients presenting with perivascular lymphocytic infiltration had lower chromium concentration in their periprosthetic tissues than patients with no perivascular lymphocytic infiltration. This may reflect the role of metal hypersensitivity in implant failure in these patients. Patients with total hip replacements evinced more necrosis and lymphocytic infiltration in their tissues than patients with hip resurfacings. This suggests that trunnion wear debris is more cytotoxic and/or immunogenic than bearing wear debris leading to higher failure rates seen in patients with total hip replacements.
Collapse
Affiliation(s)
- Lari Lehtovirta
- University of Tampere, Tampere, Finland
- Coxa Hospital for Joint Replacement, Tampere, Finland
- * E-mail:
| | - Aleksi Reito
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | | | | | | | | |
Collapse
|
21
|
Abstract
INTRODUCTION Metal ion release from wear and corrosion at the femoral head-stem taper junction can evoke local adverse reactions to metal debris (ARMD). In a specific large-diameter head (LDH) total hip arthroplasty (THA) system, ceramic femoral heads of 44 to 48 mm are available with a titanium (Ti) adaptor sleeve, while heads of 36- to 40-mm come without sleeves. The hypothesis of this study is that the Ti adaptor sleeve with LDH ceramic-on-ceramic (CoC) bearings will not cause wear or corrosion at the taper junction and, thus, will not generate high whole blood Ti ion levels. METHODS We compared whole blood Ti levels at minimum 1-year follow-up in 27 patients with unilateral primary LDH CoC THA with head sizes ranging from 36 to 48 mm using a Ti stem and acetabular component. RESULTS Although Ti ion levels in patients with 36- to 40-mm head diameters without Ti sleeve were found to be statistically significantly higher (2.3 μg/l: 1.6-3.1, SD 0.44) compared to those with a Ti sleeve (1.9 μg/l: 1.6-2.2, SD 0.19) (p = 0.020), the found difference has no clinical importance. No patients presented clinical signs of ARMD, and the clinical results in both groups were similar. CONCLUSIONS LDH CoC THA Ti levels were low and probably related to unavoidable passive corrosion of implant surfaces. Measurement of Ti in subjects with ceramic LDH, with or without Ti adaptor sleeve, did not disclose undirected signs of trunnionosis.
Collapse
|
22
|
Predictive factors for metal ion levels in metal-on-metal total hip arthroplasty. Arch Orthop Trauma Surg 2018; 138:281-286. [PMID: 29260384 DOI: 10.1007/s00402-017-2856-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2017] [Indexed: 02/09/2023]
Abstract
INTRODUCTION Although metal-on-metal (MoM) total hip arthroplasty (THA) and hip resurfacings (HR) have similar bearing surfaces and comparable wear rates, metal ion levels and risk of failure are higher for MoM-THA. The mechanism behind the increased metal ion levels in large head MoM-THA is not completely understood. The current study aims to identify predictive factors for increased metal ion levels in unilateral and bilateral large head MoM-THA. MATERIALS AND METHODS 99 Birmingham modular MoM-THA in 87 patients with metal ion levels at least 36 months after index procedure were analyzed. Mean follow-up time was 61.3 months (range 37-108) and the relationship of the following variables (gender, age, BMI, follow-up time, UCLA Activity Score, cup inclination, femoral head size, bilateral surgery) on metal ion levels were analyzed with multivariate regression models. RESULTS Multivariate regression analysis revealed that bilateral MoM-THA surgery (p < 0.001) had a positive predictive effect on cobalt serum levels, while BMI had a negative (p = 0.018). Female gender (p = 0.012), activity (p = 0.001) and bilateral MoM-THA (p = 0.004) were positively correlated with chromium levels. Positive independent predictors for the cobalt-chromium ratio in the multivariate analysis were overall follow-up time (p = 0.004), bilateral MoM-THA (p < 0.001) and femoral head size (p = 0.007). CONCLUSIONS The data of the current study suggest that bilateral MoM-THA, increased patient activity levels and female gender are associated with increased chromium levels. Patients with larger component size, longer follow-up time and bilateral MoM-THAs have an increased cobalt-chromium ratio. These patients might be at increased risk for adverse local soft tissue reactions secondary to corrosion. Continuous close monitoring is recommended and bearing-surface change should be discussed if local tissue reactions occur.
Collapse
|
23
|
Koller D, Bramhall P, Devoy J, Goenaga-Infante H, Harrington CF, Leese E, Morton J, Nuñez S, Rogers J, Sampson B, Powell JJ. Analysis of soluble or titanium dioxide derived titanium levels in human whole blood: consensus from an inter-laboratory comparison. Analyst 2018; 143:5520-5529. [DOI: 10.1039/c8an00824h] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Exposure to titanium (Ti),viathe ingestion of pigment grade Ti dioxide (TiO2), is commonplace for westernised populations.
Collapse
Affiliation(s)
- D. Koller
- Biomineral Research Group
- Department of Veterinary Medicine
- University of Cambridge
- Cambridge
- UK
| | - P. Bramhall
- University Hospital of Wales TRACE ELEMENT LABORATORY
- Department of Medical Biochemistry and Immunology
- Cardiff
- UK
| | - J. Devoy
- INRS
- Unité de Génération d'atmosphères et de Chimie Analytique Toxicologique
- 54519 Vandoeuvre-lès-Nancy
- France
| | | | | | - E. Leese
- Health and Safety Executive
- Biological Monitoring
- Buxton
- UK
| | - J. Morton
- Health and Safety Executive
- Biological Monitoring
- Buxton
- UK
| | - S. Nuñez
- LGC Limited
- Inorganic Analysis
- Teddington
- UK
| | - J. Rogers
- University Hospital of Wales TRACE ELEMENT LABORATORY
- Department of Medical Biochemistry and Immunology
- Cardiff
- UK
| | - B. Sampson
- Charing Cross Hospital
- SAS Trace Element Laboratory
- London
- UK
| | - J. J. Powell
- Biomineral Research Group
- Department of Veterinary Medicine
- University of Cambridge
- Cambridge
- UK
| |
Collapse
|
24
|
Barry J, Kiss MO, Massé V, Lavigne M, Matta J, Vendittoli PA. Effect of Femoral Stem Modular Neck's Material on Metal Ion Release. Open Orthop J 2017; 11:1337-1344. [PMID: 29290872 PMCID: PMC5721328 DOI: 10.2174/1874325001711011337] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2017] [Revised: 11/11/2017] [Accepted: 11/16/2017] [Indexed: 11/22/2022] Open
Abstract
Background: In recent decades, the popularity of modular necks in total hip arthroplasty (THA) has increased since modular necks offer the potential to restore the patient’s native anatomy, and thus improve stability. Unfortunately, modular necks are associated with higher complication rates, including implant fracture and modular junction corrosion with adverse local tissue reaction to metal debris. Objective: The objective of this study was to determine the impact of modular neck material on titanium (Ti), chrome (Cr), and cobalt (Co) metal ion levels in patients who underwent a THA with Ti femoral stem, Ti or CrCo modular neck, and ceramic-on-ceramic (CoC) bearing. Methods: Whole blood Ti, Cr, and Co levels were compared at a minimum 1-year follow-up in 36 patients who underwent unilateral, primary CoC large-diameter head THA with Profemur® Preserve modular femoral stems (MicroPort, Arlington, TX, USA). Results: Higher Co concentrations were observed in the CrCo modular neck group (0.46 versus 0.26 µg/l in the Ti neck group, P=0.004) and higher Ti concentrations were observed in the Ti modular neck group (1.98 vs 1.59 µg/l in the CrCo neck group, P=0.007). However, these differences were not clinically meaningful since the absolute values remained within what is considered the safe range of Ti, Cr, and Co ions in whole blood. No patients were re-operated or revised. Conclusion: Modular neck materials had an impact on whole blood metal ion levels but the concentrations measured remained within the safe range at 1-year follow-up. There were no indirect signs of modular junction corrosion with either CrCo or Ti femoral necks.
Collapse
Affiliation(s)
- Janie Barry
- Hôpital Maisonneuve-Rosemont, Université de Montréal, 5415 Boulevard de l'Assomption, Montreal, Canada
| | - Marc-Olivier Kiss
- Hôpital Maisonneuve-Rosemont, Université de Montréal, 5415 Boulevard de l'Assomption, Montreal, Canada
| | - Vincent Massé
- Hôpital Maisonneuve-Rosemont, Université de Montréal, 5415 Boulevard de l'Assomption, Montreal, Canada
| | - Martin Lavigne
- Hôpital Maisonneuve-Rosemont, Université de Montréal, 5415 Boulevard de l'Assomption, Montreal, Canada
| | - Jihad Matta
- Hôpital Maisonneuve-Rosemont, Université de Montréal, 5415 Boulevard de l'Assomption, Montreal, Canada
| | - Pascal-Andre Vendittoli
- Hôpital Maisonneuve-Rosemont, Université de Montréal, 5415 Boulevard de l'Assomption, Montreal, Canada
| |
Collapse
|
25
|
Fortmann C, Göen T, Krüger M, Ure BM, Petersen C, Kübler JF. Trace metal release after minimally-invasive repair of pectus excavatum. PLoS One 2017; 12:e0186323. [PMID: 29023602 PMCID: PMC5638555 DOI: 10.1371/journal.pone.0186323] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2017] [Accepted: 09/18/2017] [Indexed: 11/18/2022] Open
Abstract
Background Several studies have shown a high incidence of metal allergy after minimally-invasive repair of pectus excavatum (MIRPE). We postulated that MIRPE is associated with a significant release of trace metal ions, possibly causing the allergic symptoms. Methods We evaluated the concentration with chromium, cobalt and nickel in blood, urine and tissue in patients prior to MIRPE and in patients who underwent an explantation of the stainless-steel bar(s) after three years. Results Our study group consisted of 20 patients (mean age 19 years) who had bar explantation and our control group included 20 patients (mean age 16 years) prior to MIRPE. At the time of bar removal we detected significantly elevated concentrations of chromium and nickel in the tissue compared to patients prior to the procedure (p<0,001). We also found a significant increase in the levels of chromium in urine and nickel in blood in patients three years post MIRPE (p<0,001). Four patients temporarily developed symptoms of metal allergy, all had elevated metal values in blood and urine at explantation. Conclusions Minimally-invasive repair of pectus excavatum can lead to a significant trace metal exposure.
Collapse
Affiliation(s)
- Caroline Fortmann
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
- * E-mail:
| | - Thomas Göen
- Institute and Outpatient Clinic of Occupational, Social and Environmental Medicine, Friedrich-Alexander-University Erlangen-Nürnberg, Erlangen, Germany
| | - Marcus Krüger
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Benno M. Ure
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
| | - Claus Petersen
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
| | - Joachim F. Kübler
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
| |
Collapse
|
26
|
Haider H, Weisenburger JN, Namavar F, Garvin KL. Why Coating Technologies for Hip Replacement Systems, and the Importance of Testing Them In Vitro. ACTA ACUST UNITED AC 2017. [DOI: 10.1053/j.oto.2017.05.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
27
|
Lons A, Putman S, Pasquier G, Migaud H, Drumez E, Girard J. Metallic ion release after knee prosthesis implantation: a prospective study. INTERNATIONAL ORTHOPAEDICS 2017; 41:2503-2508. [PMID: 28616704 DOI: 10.1007/s00264-017-3528-9] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2017] [Accepted: 05/25/2017] [Indexed: 11/29/2022]
Abstract
INTRODUCTION Metal-on-metal (MoM) hip replacement bearings produce metallic ions that can cause health complications. Metallic release also occurs with other materials, but data on metallic ion levels after knee arthroplasty are sparse. We postulate that knee replacement generates elevating metallic ions (chromium (Cr), cobalt (Co) and titanium (Ti)) during the first year after implantation. PATIENTS AND METHODS This ongoing prospective study included all patients who underwent the same type of knee arthroplasty between May and December 2013. Cr, Co and Ti levels were measured in whole blood at pre-operation and one-year follow-up (6 and 12 months). Clinical and radiographic data (range of motion, Oxford, International Knee Society (IKS) and satisfaction scores) were recorded. RESULTS In 90 patients, preoperative Cr, Co and Ti metallic ion levels were respectively 0.45 μg/l, 0.22 μg/l, 2.94 μg/l and increased to 1.27 μg/l, 1.41 μg/l, 4.08 μg/l (p < 0.0001) at last one-year follow-up. Mean Oxford and IKS scores rose, respectively, from 45.9 (30-58) and 24.9 (12-52) to 88.3 (0-168) and 160.8 (93-200) (p < 0.001). CONCLUSION After the implantation of knee arthroplasty, we found significant blood elevation of Cr, Co and Ti levels one year after implantation exceeding the normal values. This metallic ion release could lead to numerous effects: allergy, hypersensitivity, etc.
Collapse
Affiliation(s)
- Adrien Lons
- Université de Lille Nord de France, F-59000, Lille, France
- Service d'Orthopédie, Hôpital Salengro, Centre Hospitalier Universitaire de Lille, Place de Verdun, 59037, Lille, Cedex, France
| | - Sophie Putman
- Université de Lille Nord de France, F-59000, Lille, France
- Service d'Orthopédie, Hôpital Salengro, Centre Hospitalier Universitaire de Lille, Place de Verdun, 59037, Lille, Cedex, France
| | - Gilles Pasquier
- Université de Lille Nord de France, F-59000, Lille, France
- Service d'Orthopédie, Hôpital Salengro, Centre Hospitalier Universitaire de Lille, Place de Verdun, 59037, Lille, Cedex, France
| | - Henri Migaud
- Université de Lille Nord de France, F-59000, Lille, France
- Service d'Orthopédie, Hôpital Salengro, Centre Hospitalier Universitaire de Lille, Place de Verdun, 59037, Lille, Cedex, France
| | - Elodie Drumez
- Unité de Biostatistiques, Université Lille, Centre Hospitalier Universitaire Lille, EA 2694 - Santé publique: épidémiologie et qualité des soins, F-59000, Lille, France
| | - Julien Girard
- Université de Lille Nord de France, F-59000, Lille, France.
- Service d'Orthopédie, Hôpital Salengro, Centre Hospitalier Universitaire de Lille, Place de Verdun, 59037, Lille, Cedex, France.
| |
Collapse
|
28
|
The Role of Metal-on-Metal Bearings in Total Hip Arthroplasty and Hip Resurfacing: Review Article. HSS J 2017; 13:2-6. [PMID: 28167866 PMCID: PMC5264575 DOI: 10.1007/s11420-016-9521-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2015] [Accepted: 07/20/2016] [Indexed: 02/07/2023]
Abstract
BACKGROUND The current role of metal-on-metal (MoM) bearings in hip arthroplasty remains controversial. The low wear offered by MoM bearings compared to metal-on-polyethylene and the possibility of a lower risk of dislocation with larger head sizes, encouraged a trend towards the re-introduction of the MoM bearing couple. However, recent evidence has shown that not all designs of the MoM bearing have been successful. QUESTIONS/PURPOSES The purpose of this paper is to provide an update on the use of MoM bearings and address the following issues: (1) the reintroduction of metal-on-metal bearings in total hip arthroplasty, (2) the failure of metal-on-metal bearings in stemmed total hip arthroplasty, (3) the role of metal-on-metal hip resurfacing in modern orthopaedics and (4) metal-on-metal hip resurfacing versus total hip arthroplasty. METHODS A literature search strategy was conducted using various search terms in MEDLINE and Embase. The highest quality articles that met the inclusion criteria and best answered the topics of focus of this review were selected. Key search terms included 'metal-on-metal', 'total hip arthroplasty' and 'hip resurfacing'. RESULTS The initial search retrieved 1240 articles. Twenty-two articles were selected and used in the review. CONCLUSION Metal-on-metal hip resurfacing is still a suitable treatment option in specific patient populations with the appropriate implant design and surgical skill, while stemmed metal-on-metal total hip arthroplasty should be avoided in all patient populations. Continued follow-up of patients undergoing metal-on-metal hip resurfacing is critical in order to further understand the long-term outcomes of these patients and why certain complications tend to occur with this procedure.
Collapse
|
29
|
Liow MHL, Kwon YM. Metal-on-metal total hip arthroplasty: risk factors for pseudotumours and clinical systematic evaluation. INTERNATIONAL ORTHOPAEDICS 2016; 41:885-892. [PMID: 27761629 DOI: 10.1007/s00264-016-3305-1] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2016] [Accepted: 09/25/2016] [Indexed: 12/12/2022]
Abstract
The potential advantages of contemporary MoM THA implants include less volumetric wear with subsequent reduction of polyethylene wear-induced osteolysis and greater component stability with use of large-diameter femoral heads. However, there have been concerns regarding significantly elevated revision rates in MoM THA due to MoM-related complications such as adverse local tissue reaction (pseudotumour) formation. The increased failure rate in MoM hip arthroplasty is associated with the generation of biologically active, nanometer sized metal particles from the MoM bearing surfaces and taper junctions, which result in the development of a localized, adverse periprosthetic soft tissue response. The focus of this article is to provide an update on (1) implant, surgical and patient factors associated with adverse local tissue reactions (pseudotumours) and (2) the clinical systematic evaluation and management of patients with MoM hip arthroplasty based on the currently available evidence. There should be a low threshold to conduct a systematic clinical evaluation of patients with MoM hip arthroplasty as early recognition and diagnosis will allow the initiation of prompt and appropriate treatment. As a symptomatic MoM total hip arthroplasty may have intrinsic and extrinsic causes, patients should be evaluated systematically, utilizing risk stratification algorithms. Although specialized laboratory tests such as metal ion levels and cross sectional imaging modalities such as MARS MRI can be used to facilitate clinical decision making, over-reliance on any single investigative tool in the clinical decision-making process should be avoided. Further research is required to obtain a better understanding of implant and patient risk factors associated with tribocorrosion in MoM total hip arthroplasty.
Collapse
Affiliation(s)
- Ming Han Lincoln Liow
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Young-Min Kwon
- Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
30
|
Munir S, Oliver RA, Zicat B, Walter WL, Walter WK, Walsh WR. The histological and elemental characterisation of corrosion particles from taper junctions. Bone Joint Res 2016; 5:370-8. [PMID: 27608650 PMCID: PMC5017139 DOI: 10.1302/2046-3758.59.2000507] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2015] [Accepted: 05/24/2016] [Indexed: 01/01/2023] Open
Abstract
OBJECTIVES This study aimed to characterise and qualitatively grade the severity of the corrosion particles released into the hip joint following taper corrosion. METHODS The 26 cases examined were CoC/ABG Modular (n = 13) and ASR/SROM (n = 13). Blood serum metal ion levels were collected before and after revision surgery. The haematoxylin and eosin tissue sections were graded on the presence of fibrin exudates, necrosis, inflammatory cells and corrosion products. The corrosion products were identified based on visible observation and graded on abundance. Two independent observers blinded to the clinical patient findings scored all cases. Elemental analysis was performed on corrosion products within tissue sections. X-Ray diffraction was used to identify crystalline structures present in taper debris. RESULTS The CoC/ABG Modular patients had a mean age of 64.6 years (49.4 to 76.5) and ASR/SROM patients had a mean age of 58.2 years (33.3 to 85.6). The mean time in situ for CoC/ABG was 4.9 years (2 to 6.4) and ASR/SROM was 6.1 years (2.5 to 8.1). The blood serum metal ion concentrations reduced following revision surgery with the exception of Cr levels within CoC/ABG. The grading of tissue sections showed that the macrophage response and metal debris were significantly higher for the ASR/SROM patients (p < 0.001). The brown/red particles were significantly higher for ASR/SROM (p < 0.001). The taper debris contained traces of titanium oxide, chromium oxide and aluminium nitride. CONCLUSION This study characterised and qualitatively graded the severity of the corrosion particles released into the hip joint from tapers that had corrosion damage.Cite this article: S. Munir, R. A. Oliver, B. Zicat, W. L. Walter, W. K. Walter, W. R. Walsh. The histological and elemental characterisation of corrosion particles from taper junctions. Bone Joint Res 2016;5:370-378. DOI: 10.1302/2046-3758.59.2000507.
Collapse
Affiliation(s)
- S Munir
- Prince of Wales Clinical School Level 1, Clinical Science Bldg, Prince of Wales Hospital Gate 6 Avoca Street Sydney, 2031 Australia
| | - R A Oliver
- Prince of Wales Clinical School Level 1, Clinical Science Bldg, Prince of Wales Hospital Gate 6 Avoca Street Sydney, 2031 Australia
| | - B Zicat
- Specialist Orthopaedic Group, Suite 1.08, Level One, 3 - 9 Gillies Street Wollstonecraft NSW 2065, Australia
| | - W L Walter
- Specialist Orthopaedic Group, Suite 1.08, Level One, 3 - 9 Gillies Street Wollstonecraft NSW 2065, Australia
| | - W K Walter
- Specialist Orthopaedic Group, Suite 1.08, Level One, 3 - 9 Gillies Street Wollstonecraft NSW 2065, Australia
| | - W R Walsh
- Prince of Wales Clinical School Level 1, Clinical Science Bldg, Prince of Wales Hospital Gate 6 Avoca Street Sydney, 2031 Australia
| |
Collapse
|
31
|
Vogt N, Wozniak K, Salito A, Wild MD. Biocompatible wear-resistant thick ceramic coating. CURRENT DIRECTIONS IN BIOMEDICAL ENGINEERING 2016. [DOI: 10.1515/cdbme-2016-0010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Abstract
Sensitisation to immunologically active elements like chromium, cobalt or nickel and debris particle due to wear are serious problems for patients with metallic implants. We tested the approach of using a hard and thick ceramic coating as a wear-resistant protection of titanium implants, avoiding those sensitisation and foreign body problems. We showed that the process parameters strongly influence the coating porosity and, as a consequence, also its hardness.
Collapse
Affiliation(s)
- Nicola Vogt
- University of Applied Sciences Northwestern Switzerland, FHNW, School of Life Sciences, Institute for Medical and Analytical Technologies, Gründenstrasse 40, CH-4132 Muttenz, Switzerland
| | - Katarzyna Wozniak
- Orchid Orthopaedics Switzerland, Täfernstrasse 39, CH-5405 Dättwil AG, Switzerland
| | - Armando Salito
- Orchid Orthopaedics Switzerland, Täfernstrasse 39, CH-5405 Dättwil AG, Switzerland
| | - Michael de Wild
- University of Applied Sciences Northwestern Switzerland, FHNW, School of Life Sciences, Institute for Medical and Analytical Technologies, Gründenstrasse 40, CH-4132 Muttenz, Switzerland
| |
Collapse
|
32
|
Vasconcelos DM, Santos SG, Lamghari M, Barbosa MA. The two faces of metal ions: From implants rejection to tissue repair/regeneration. Biomaterials 2016; 84:262-275. [DOI: 10.1016/j.biomaterials.2016.01.046] [Citation(s) in RCA: 64] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2015] [Revised: 01/20/2016] [Accepted: 01/21/2016] [Indexed: 12/20/2022]
|
33
|
Repeated metal ion measurement in patients with bilateral metal on metal (ASR™) hip replacements. Orthop Traumatol Surg Res 2016; 102:167-73. [PMID: 26874448 DOI: 10.1016/j.otsr.2015.12.015] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2015] [Revised: 12/13/2015] [Accepted: 12/17/2015] [Indexed: 02/02/2023]
Abstract
BACKGROUND Blood metal ion measurements have become a cornerstone in the surveillance of metal-on-metal (MoM) hip replacements. Interpretation of these levels in patients with bilateral MoM hip replacements, however, is challenging. We therefore asked (1) if there is a clinically significant change in whole blood (WB) Co or Cr levels in repeated WB assessment in patients operated on with bilateral ASR hip replacements, and (2) what proportion of patients has WB Co or Cr level below the previously established safe upper limits (SUL) (Co<5.0μg/L, Cr<7.4μg/L) in the repeated WB metal ion assessment. HYPOTHESIS We hypothesized that there is a significant difference between repeated Co and Cr level measurement performed within one year±4 months interval in patients with bilateral ASR hip replacements. MATERIALS AND METHODS We identified all patients (n=139) who had received bilateral ASR hip replacements (278 hips). Patients (n=76, 152 hips) who had undergone two blood metal ion measurements within eight to sixteen months' time interval were included in the study analysis. Study cohort included 38 patients with bilateral ASR hip resurfacings (mean age 53 years, median follow-up 4.6 years, median femoral diameter 51mm) and 38 patients with bilateral ASR XL total hip replacements (mean age 60 years, median follow-up 3.6 years, median femoral diameter 49mm). RESULTS There was no significant change in Co and Cr levels between the repeated measurements in the HR cohort. Both Co and Cr were significantly higher in the THR cohort in the repeated measurement (Co: 8.3μg/L vs. 12.6μg/L, Cr: 3.15μg/L vs. 3.4μg/L, both P<0.001). WB Co and Cr levels remained below SUL and within their initial values during a mean one-year measurement interval in the majority of patients with bilateral high risk HR device. In contrast to this, 21.1% of patients with THRs had WB Co ion levels exceeding the SUL in the first measurement. WB Co values significantly increased over the measurement interval in the THR group. DISCUSSION Annual blood metal ion measurement is not useful in patients with bilateral hip resurfacings who have undergone at least one preliminary screening including both metal ion measurement and cross-sectional imaging. It seems, however, to be beneficial in patients with bilateral high risk MoM THR. LEVEL OF EVIDENCE Level III (retrospective comparative study).
Collapse
|
34
|
Yi Z, Bo Z, Bin S, Jing Y, Zongke Z, Fuxing P. Clinical Results and Metal Ion Levels After Ceramic-on-Metal Total Hip Arthroplasty: A Mean 50-Month Prospective Single-Center Study. J Arthroplasty 2016; 31:438-41. [PMID: 26515043 DOI: 10.1016/j.arth.2015.09.034] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2014] [Revised: 09/14/2015] [Accepted: 09/15/2015] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The aim of our study was to investigate the clinical results and serum metal ion levels in a cohort of patients who received total hip arthroplasty (THA) with ceramic-on-metal (CoM) bearings. METHODS From September 2009 to December 2011, 78 patients (89 hips) who underwent THA with CoM bearings were involved in this study. Harris Hip Score, Short-Form 12, and Western Ontario and McMaster Universities Osteoarthritis Index scores were measured and radiographs were taken for radiographic analysis. Serum metal ion levels of cobalt (Co), chromium (Cr), molybdenum (Mo), and titanium (Ti) were measured using high-resolution inductively coupled plasma-mass spectrometry. RESULTS Severy-four patients (85 hips) were followed up at a mean of 50 months. At the end of follow-up, HSS, Short-Form 12, and Western Ontario and McMaster Universities Osteoarthritis Index scores were improved significantly compared with preoperative values. No intraoperative and postoperative complications occurred, and no radiolucency, osteolysis, and loosening was found from radiographic examination. Metal ion analysis showed that serum metal ions levels were significantly elevated compared with normal values. Spearman correlation analysis revealed that there was a correlation between 3 metal ion levels and body mass index(Co: r = 0.49, P < .01; Cr: r = 0.47, P < .01; Mo: r = 0.36, P = .04). No correlation was found between metal ion levels and age, cup abduction angle, cup anteversion angle, acetabular version, bilateral arthroplasty, cup screw used, hip stem implant type, or femoral head size. CONCLUSION Our study concluded that the use of a CoM THA is effective clinically, but the systemic metal ion levels are significantly elevated at midterm follow-up. Whether the elevated metal ion levels will induce an adverse reaction is unknown and long-term follow-up is need.
Collapse
Affiliation(s)
- Zeng Yi
- Department of Orthopaedic Surgery, West China Hospital, West China Medical School, Sichuan University, Chengdu, Sichuan Province, China
| | - Zheng Bo
- Analysis and Testing Center, West China School of Public Health, Sichuan Univeristy, Chengdu, Sichuan Province, China
| | - Shen Bin
- Department of Orthopaedic Surgery, West China Hospital, West China Medical School, Sichuan University, Chengdu, Sichuan Province, China
| | - Yang Jing
- Department of Orthopaedic Surgery, West China Hospital, West China Medical School, Sichuan University, Chengdu, Sichuan Province, China
| | - Zhou Zongke
- Department of Orthopaedic Surgery, West China Hospital, West China Medical School, Sichuan University, Chengdu, Sichuan Province, China
| | - Pei Fuxing
- Department of Orthopaedic Surgery, West China Hospital, West China Medical School, Sichuan University, Chengdu, Sichuan Province, China
| |
Collapse
|
35
|
Serum Metal Ions with a Titanium Modular Neck Total Hip Replacement System. J Arthroplasty 2015; 30:1781-6. [PMID: 26027522 DOI: 10.1016/j.arth.2015.04.040] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2014] [Revised: 03/28/2015] [Accepted: 04/20/2015] [Indexed: 02/01/2023] Open
Abstract
The goal of this study is to evaluate serum levels of chromium (Cr), cobalt (Co), and titanium (Ti) within the first two years following total hip arthroplasty using a Ti modular neck system. Twenty-five patients were randomized to a metal-on-metal (MoM) bearing with an all CoCr shell, and the remaining 25 received a metal-on-polyethylene (MoP) with a Ti shell. Serum levels demonstrated increases for Cr, Co, and Ti at 1 year (P < .001). MoM had similar Ti levels to MoP hips at 1 year (P=0.11) but lower at 2 years (P=0.03). Results suggest that the passive corrosion (i.e., chemical, pitting, and crevice corrosion) of exposed non-articular metal surfaces may be a greater source of ions than the neck-stem or head-neck interfaces.
Collapse
|
36
|
Singh R, Manoharan G, Craig P, Collier S, Shaylor P, Sinha A. Blood metal ions after hybrid metal-on-polyethylene Exeter-Trident total hip replacement. J Orthop Traumatol 2015. [PMID: 26206329 PMCID: PMC4882294 DOI: 10.1007/s10195-015-0369-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Background Metal-on-metal total hip replacements (THRs) with large femoral heads have been associated with elevated levels of cobalt (Co) and chromium (Cr), which have been attributed to high levels of wear at the articular surface. Our unit recently published data showing a significant increase in the mean levels of Co ions in patients with a 36-mm diameter femoral head with the metal-on-polyethylene Trident−Accolade system. The aim of this study is to assess the levels of Co and Cr in the Exeter−Trident hybrid system, as similar findings would raise concern over the V40 taper trunnion. Materials and methods The study included 83 patients (45 male and 38 female with a mean age of 75.6 years) who received Exeter−Trident hybrid metal-on-polyethylene THRs. The patients were then divided into two groups according to the diameter of the femoral head used—38 patients in the 28-mm group (control), and 45 in the 36-mm (experimental) group. Serum levels of blood Co and Cr were analysed for all recruited patients. Results In the control group (28-mm femoral head) all Co and Cr values were normal (under the abnormal threshold), as were the experimental group (36-mm femoral head). The data values were below <10 nmol and <40 nmol for Co and Cr, respectively. Conclusion Since the National Joint Registry (NJR) states that the Exeter femoral stem is the commonest cemented femoral stem prosthesis used in the UK, we found it imperative that these results are documented given the corresponding findings in the Trident−Accolade system in our previous study. This study provides relative reassurance that the issue does not lie with the V40 taper trunnion, but raises suspicion that the issue may be with the titanium Accolade stem with large diameter femoral heads. Level of evidence III.
Collapse
Affiliation(s)
- Rohit Singh
- Robert Jones Orthopaedic Hospital, Oswestry, UK.
| | | | - Pete Craig
- Robert Jones Orthopaedic Hospital, Oswestry, UK
| | - Simon Collier
- Mid Staffordshire foundation trust, Stafford, England, UK
| | | | - Ashok Sinha
- Mid Staffordshire foundation trust, Stafford, England, UK
| |
Collapse
|
37
|
Fracture of the Modular Neck in Total Hip Arthroplasty. Case Rep Orthop 2015; 2015:591509. [PMID: 26266069 PMCID: PMC4525462 DOI: 10.1155/2015/591509] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2015] [Revised: 06/11/2015] [Accepted: 06/16/2015] [Indexed: 11/27/2022] Open
Abstract
Modularity of the components in total hip arthroplasty has had an increase in popularity in the last decades. We present the case of a 53-year-old man with a history of avascular necrosis of the femoral head due to a hypophyseal adenoma. A total hip modular arthroplasty was implanted. Three and a half years after the surgery the patient attended the emergency room due to acute left hip pain with no prior traumatism. Radiological examination confirmed a fracture of the modular neck. A revision surgery was performed finding an important pseudotumoral well-organized periprosthetic tissue reaction. Through an extended trochanteric osteotomy the femoral component was removed, and a straight-stem revision prosthesis implanted. There are several potential advantages when using modularity in total hip arthroplasty that surgeons may benefit from, but complications have arisen and must be addressed. Various circumstances such as large femoral head with a long varus neck, corrosion, patient's BMI, and activity level may participate in creating the necessary environment for fatigue failure of the implant.
Collapse
|
38
|
What are the predictors and prevalence of pseudotumor and elevated metal ions after large-diameter metal-on-metal THA? Clin Orthop Relat Res 2015; 473:477-84. [PMID: 25085361 PMCID: PMC4294930 DOI: 10.1007/s11999-014-3824-2] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Soft tissue masses, or "pseudotumors," around metal-on-metal total hip arthroplasty (MoM THA) have been reported frequently; however, their prevalence remains unknown. Several risk factors, including elevated metal ion levels, have been associated with the presence of pseudotumor, although this remains controversial. QUESTIONS/PURPOSES The goals of this study were to (1) determine the prevalence of pseudotumors after large-diameter head MoM THA; (2) identify risk factors associated with pseudotumor formation and elevated metal ion levels; and (3) determine the early failure rate of large-diameter MoM THA. METHODS Between December 2005 and November 2012, 258 hips (215 patients) underwent large-diameter head primary MoM THA at our institution. Clinical followup was obtained in 235 hips (91%). Using an inclusion criteria of a minimum followup of 1 year, a subset of 191 hips (mean followup, 4 years; range, 1-7 years) was recruited for high-resolution ultrasound screening for the presence of pseudotumor. Whole blood cobalt and chromium ion levels, UCLA activity level, WOMAC score, patient demographics as well as surgical, implant, and radiographic data were collected. Bivariate correlations and multivariate log-linear regression models were used to compare the presence of pseudotumor and elevated metal ions with all other factors. RESULTS Ultrasound detected a solid, cystic, or mixed mass in 20% hips (38 of 191). No correlation was found between the presence of pseudotumor and any risk factor that we examined. After controlling for confounding variables, elevated cobalt ions were correlated (p<0.001, R=0.50, R2=0.25) with smaller femoral head size, the presence of bilateral MoM THA, and female sex. Elevated chromium ions were correlated (p<0.001, R=0.59, R2=0.34) with smaller femoral head size, presence of bilateral MoM THA, and lower body mass index. The overall survival of MoM THA was 96% at a mean followup of 4.5 years (range, 2-8 years). CONCLUSIONS With the numbers available, we found no associations between the presence of pseudotumor and the potential risk factors we analyzed, including elevated metal ion levels. Further work is needed to explain why larger femoral head sizes resulted in lower metal ion levels despite being associated with higher early failure rates in joint registry data. LEVEL OF EVIDENCE Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Collapse
|
39
|
Femoral head diameter considerations for primary total hip arthroplasty. Orthop Traumatol Surg Res 2015; 101:S25-9. [PMID: 25596984 DOI: 10.1016/j.otsr.2014.07.026] [Citation(s) in RCA: 49] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2014] [Revised: 05/07/2014] [Accepted: 07/08/2014] [Indexed: 02/02/2023]
Abstract
The configuration of total hip arthroplasty (THA) implants has constantly evolved since they were first introduced. One of the key components of THA design is the diameter of the prosthetic femoral head. It has been well established that the risk of dislocation is lower as the head diameter increases. But head diameter impacts other variables beyond joint stability: wear, cam-type impingement, range of motion, restoration of biomechanics, proprioception and groin pain. The introduction of highly cross-linked polyethylene and hard-on-hard bearings has allowed surgeons to implant large-diameter heads that almost completely eliminate the risk of dislocation. But as a result, cup liners have become thinner. With femoral head diameters up to 36 mm, the improvement in joint range of motion, delay in cam-type impingement and reduction in dislocation risk have been clearly demonstrated. Conversely, large-diameter heads do not provide any additional improvements. If an "ecologically sound" approach to hip replacement is embraced (e.g. keeping the native femoral head diameter), hip resurfacing with a metal-on-metal bearing must be carried out. The reliability of large-diameter femoral heads in the longer term is questionable. Large-diameter ceramic-on-ceramic bearings may be plagued by the same problems as metal-on-metal bearings: groin pain, squeaking, increased stiffness, irregular lubrication, acetabular loosening and notable friction at the Morse taper. These possibilities require us to be extra careful when using femoral heads with a diameter greater than 36 mm.
Collapse
|
40
|
Rahmé M, Lavigne M, Barry J, Cirtiu CM, Bélanger P, Vendittoli PA. Whole blood metal ion measurement reproducibility between different laboratories. J Arthroplasty 2014; 29:2214-8. [PMID: 25155139 DOI: 10.1016/j.arth.2014.07.018] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/10/2014] [Revised: 06/11/2014] [Accepted: 07/19/2014] [Indexed: 02/01/2023] Open
Abstract
Monitoring patients' metal ion blood concentrations can be useful in cases of problematic metal on metal hip implants. Our objective was to evaluate the reproducibility of metal ion level values measured by two different laboratories. Whole blood samples were collected in 46 patients with metal on metal hip arthroplasty. For each patients, two whole blood samples were collected and analyzed by two laboratories. Laboratory 1 had higher results than laboratory 2. There was a clinically significant absolute difference between the two laboratories, above the predetermined threshold, 35% of Cr samples and 38% of Co samples. All laboratories do not use the same technologies for their measurements. Therefore, decision to revise a metal on metal hip arthroplasty should rely on metal ion trends and have to be done in the same laboratory.
Collapse
Affiliation(s)
| | | | - Janie Barry
- Hôpital Maisonneuve-Rosemont, Montréal, Québec, Canada
| | - Ciprian Mihai Cirtiu
- Centre de toxicologie du Québec, Institut National de Santé Publique du Québec, Sainte-Foy, Québec, Canada
| | - Patrick Bélanger
- Centre de toxicologie du Québec, Institut National de Santé Publique du Québec, Sainte-Foy, Québec, Canada
| | | |
Collapse
|
41
|
Gascoyne TC, Dyrkacz RM, Turgeon TR, Burnell CD, Wyss UP, Brandt JM. Corrosion on the acetabular liner taper from retrieved modular metal-on-metal total hip replacements. J Arthroplasty 2014; 29:2049-52. [PMID: 24997654 DOI: 10.1016/j.arth.2014.05.027] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/17/2014] [Revised: 05/27/2014] [Accepted: 05/31/2014] [Indexed: 02/08/2023] Open
Abstract
Eight retrieved metal-on-metal total hip replacements displayed corrosion damage along the cobalt-chromium alloy liner taper junction with the Ti alloy acetabular shell. Scanning electron microscopy indicated the primary mechanism of corrosion to be grain boundary and associated crevice corrosion, which was likely accelerated through mechanical micromotion and galvanic corrosion resulting from dissimilar alloys. Coordinate measurements revealed up to 4.3mm(3) of the cobalt-chromium alloy taper surface was removed due to corrosion, which is comparable to previous reports of corrosion damage on head-neck tapers. The acetabular liner-shell taper appears to be an additional source of metal corrosion products in modular total hip replacements. Patients with these prostheses should be closely monitored for signs of adverse reaction towards corrosion by-products.
Collapse
Affiliation(s)
- Trevor C Gascoyne
- Orthopaedic Innovation Centre, Concordia Hip and Knee Institute, 1155 Concordia Avenue, R2K 2M9
| | - Richard M Dyrkacz
- Department of Mechanical Engineering, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Thomas R Turgeon
- Orthopaedic Innovation Centre, Concordia Hip and Knee Institute, 1155 Concordia Avenue, R2K 2M9; Department of Surgery, Orthopaedics, University of Manitoba
| | - Colin D Burnell
- Orthopaedic Innovation Centre, Concordia Hip and Knee Institute, 1155 Concordia Avenue, R2K 2M9; Department of Surgery, Orthopaedics, University of Manitoba
| | - Urs P Wyss
- Orthopaedic Innovation Centre, Concordia Hip and Knee Institute, 1155 Concordia Avenue, R2K 2M9; Department of Mechanical Engineering, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Jan-M Brandt
- Orthopaedic Innovation Centre, Concordia Hip and Knee Institute, 1155 Concordia Avenue, R2K 2M9; Department of Surgery, Orthopaedics, University of Manitoba; Department of Mechanical Engineering, University of Manitoba, Winnipeg, Manitoba, Canada
| |
Collapse
|
42
|
Matusiewicz H. Potential release of in vivo trace metals from metallic medical implants in the human body: from ions to nanoparticles--a systematic analytical review. Acta Biomater 2014; 10:2379-403. [PMID: 24565531 DOI: 10.1016/j.actbio.2014.02.027] [Citation(s) in RCA: 116] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2013] [Revised: 12/04/2013] [Accepted: 02/13/2014] [Indexed: 02/06/2023]
Abstract
Metal ion release from metallic materials, e.g. metallic alloys and pure metals, implanted into the human body in dental and orthopedic surgery is becoming a major cause for concern. This review briefly provides an overview of both metallic alloys and pure metals used in implant materials in dental and orthopedic surgery. Additionally, a short section is dedicated to important biomaterials and their corrosive behavior in both real solutions and various types of media that model human biological fluids and tissues. The present review gives an overview of analytical methods, techniques and different approaches applied to the measurement of in vivo trace metals released into body fluids and tissues from patients carrying metal-on-metal prostheses and metal dental implants. Reference levels of ion concentrations in body fluids and tissues that have been determined by a host of studies are compiled, reviewed and presented in this paper. Finally, a collection of published clinical data on in vivo released trace metals from metallic medical implants is included.
Collapse
|
43
|
Craig P, Bancroft G, Burton A, Collier S, Shaylor P, Sinha A. Raised levels of metal ions in the blood in patients who have undergone uncemented metal-on-polyethylene Trident-Accolade total hip replacement. Bone Joint J 2014; 96-B:43-7. [PMID: 24395309 DOI: 10.1302/0301-620x.96b1.30923] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
The issues surrounding raised levels of metal ions in the blood following large head metal-on-metal total hip replacement (THR), such as cobalt and chromium, have been well documented. Despite the national popularity of uncemented metal-on-polyethylene (MoP) THR using a large-diameter femoral head, few papers have reported the levels of metal ions in the blood following this combination. Following an isolated failure of a 44 mm Trident-Accolade uncemented THR associated with severe wear between the femoral head and the trunnion in the presence of markedly elevated levels of cobalt ions in the blood, we investigated the relationship between modular femoral head diameter and the levels of cobalt and chromium ions in the blood following this THR. A total of 69 patients received an uncemented Trident-Accolade MoP THR in 2009. Of these, 43 patients (23 men and 20 women, mean age 67.0 years) were recruited and had levels of cobalt and chromium ions in the blood measured between May and June 2012. The patients were then divided into three groups according to the diameter of the femoral head used: 12 patients in the 28 mm group (controls), 18 patients in the 36 mm group and 13 patients in the 40 mm group. A total of four patients had identical bilateral prostheses in situ at phlebotomy: one each in the 28 mm and 36 mm groups and two in the 40 mm group. There was a significant increase in the mean levels of cobalt ions in the blood in those with a 36 mm diameter femoral head compared with those with a 28 mm diameter head (p = 0.013). The levels of cobalt ions in the blood were raised in those with a 40 mm diameter head but there was no statistically significant difference between this group and the control group (p = 0.152). The levels of chromium ions in the blood were normal in all patients. The clinical significance of this finding is unclear, but we have stopped using femoral heads with a diameter of ≤ 36 mm, and await further larger studies to clarify whether, for instance, this issue particularly affects this combination of components.
Collapse
Affiliation(s)
- P Craig
- Oswestry/Stoke Orthopaedic Training Programme, Postgraduate Office, Institute of Orthopaedics, The Robert Jones & Agnes Hunt Orthopaedic Hospital NHS Foundation Trust, Oswestry, Shropshire SY10 7AG, UK
| | | | | | | | | | | |
Collapse
|
44
|
Smith J, Lee D, Bali K, Railton P, Kinniburgh D, Faris P, Marshall D, Burkart B, Powell J. Does bearing size influence metal ion levels in large-head metal-on-metal total hip arthroplasty? A comparison of three total hip systems. J Orthop Surg Res 2014; 9:3. [PMID: 24472283 PMCID: PMC3916311 DOI: 10.1186/1749-799x-9-3] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/29/2013] [Accepted: 01/21/2014] [Indexed: 01/20/2023] Open
Abstract
BACKGROUND The purpose of the study was twofold: first, to determine whether there is a statistically significant difference in the metal ion levels among three different large-head metal-on-metal (MOM) total hip systems. The second objective was to assess whether position of the implanted prostheses, patient demographics or factors such as activity levels influence overall blood metal ion levels and whether there is a difference in the functional outcomes between the systems. METHODS In a cross-sectional cohort study, three different metal-on-metal total hip systems were assessed: two monoblock heads, the Durom socket (Zimmer, Warsaw, IN, USA) and the Birmingham socket (Smith and Nephew, Memphis, TN, USA), and one modular metal-on-metal total hip system (Pinnacle, Depuy Orthopedics, Warsaw, IN, USA). Fifty-four patients were recruited, with a mean age of 59.7 years and a mean follow-up time of 41 months (12 to 60). Patients were evaluated clinically, radiologically and biochemically. Statistical analysis was performed on all collected data to assess any differences between the three groups in terms of overall blood metal ion levels and also to identify whether there was any other factor within the group demographics and outcomes that could influence the mean levels of Co and Cr. RESULTS Although the functional outcome scores were similar in all three groups, the blood metal ion levels in the larger monoblock large heads (Durom, Birmingham sockets) were significantly raised compared with those of the Pinnacle group. In addition, the metal ion levels were not found to have a statistically significant relationship to the anteversion or abduction angles as measured on the radiographs. CONCLUSIONS When considering a MOM THR, the use of a monoblock large-head system leads to higher elevations in whole blood metal ions and offers no advantage over a smaller head modular system.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | - James Powell
- Orthopaedic Trauma and Lower Extremity Reconstruction, University of Calgary, #0444 3134 Hospital Drive NW Calgary AB T2N 5A1, Canada.
| |
Collapse
|
45
|
Vendittoli PA, Rivière C, Roy AG, Barry J, Lusignan D, Lavigne M. Metal-on-metal hip resurfacing compared with 28-mm diameter metal-on-metal total hip replacement: a randomised study with six to nine years' follow-up. Bone Joint J 2013; 95-B:1464-73. [PMID: 24151264 DOI: 10.1302/0301-620x.95b11.31604] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
A total of 219 hips in 192 patients aged between 18 and 65 years were randomised to 28-mm metal-on-metal uncemented total hip replacements (THRs, 107 hips) or hybrid hip resurfacing (HR, 112 hips). At a mean follow-up of eight years (6.6 to 9.3) there was no significant difference between the THR and HR groups regarding rate of revision (4.0% (4 of 99) vs 5.8% (6 of 104), p = 0.569) or re-operation rates without revision (5.1% (5 of 99) vs 2.9% (3 of 104), p = 0.428). In the THR group one recurrent dislocation, two late deep infections and one peri-prosthetic fracture required revision, whereas in the HR group five patients underwent revision for femoral head loosening and one for adverse reaction to metal debris. The mean University of California, Los Angeles activity scores were significantly higher in HR (7.5 (sd 1.7) vs 6.9 (sd 1.7), p = 0.035), but similar mean Western Ontario and McMaster Universities Osteoarthritis Index scores were obtained (5.8 (sd 9.5) in HR vs 5.1 (sd 8.9) in THR, p = 0.615) at the last follow-up. Osteolysis was found in 30 of 81 THR patients (37.4%), mostly in the proximal femur, compared with two of 83 HR patients (2.4%) (p < 0.001). At five years the mean metal ion levels were < 2.5 μg/l for cobalt and chromium in both groups; only titanium was significantly higher in the HR group (p = 0.001). Although revision rates and functional scores were similar in both groups at mid-term, long-term survival analysis is necessary to determine whether one procedure is more advantageous than the other.
Collapse
Affiliation(s)
- P-A Vendittoli
- Hôpital Maisonneuve - Rosemont, 5415 Boul L'Assomption, Montréal, Québec H1T 2M4, Canada
| | | | | | | | | | | |
Collapse
|
46
|
Ebreo D, Bell PJ, Arshad H, Donell ST, Toms A, Nolan JF. Serial magnetic resonance imaging of metal-on-metal total hip replacements. Follow-up of a cohort of 28 mm Ultima TPS THRs. Bone Joint J 2013; 95-B:1035-9. [PMID: 23908416 DOI: 10.1302/0301-620x.95b8.31377] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Metal artefact reduction (MAR) MRI is now widely considered to be the standard for imaging metal-on-metal (MoM) hip implants. The Medicines and Healthcare Products Regulatory Agency (MHRA) has recommended cross-sectional imaging for all patients with symptomatic MoM bearings. This paper describes the natural history of MoM disease in a 28 mm MoM total hip replacement (THR) using MAR MRI. Inclusion criteria were patients with MoM THRs who had not been revised and had at least two serial MAR MRI scans. All examinations were reported by an experienced observer and classified as A (normal), B (infection) or C1-C3 (mild, moderate, severe MoM-related abnormalities). Between 2002 and 2011 a total of 239 MRIs were performed on 80 patients (two to four scans per THR); 63 initial MRIs (61%) were normal. On subsequent MRIs, six initially normal scans (9.5%) showed progression to a disease state; 15 (15%) of 103 THRs with sequential scans demonstrated worsening disease on subsequent imaging. Most patients with a MoM THR who do not undergo early revision have normal MRI scans. Late progression (from normal to abnormal, or from mild to more severe MoM disease) is not common and takes place over several years.
Collapse
Affiliation(s)
- D Ebreo
- Norfolk & Norwich University Hospital, Department of Orthopaedic Surgery, Colney Lane, Norwich, UK.
| | | | | | | | | | | |
Collapse
|
47
|
Hartmann A, Hannemann F, Lützner J, Seidler A, Drexler H, Günther KP, Schmitt J. Metal ion concentrations in body fluids after implantation of hip replacements with metal-on-metal bearing--systematic review of clinical and epidemiological studies. PLoS One 2013; 8:e70359. [PMID: 23950923 PMCID: PMC3737219 DOI: 10.1371/journal.pone.0070359] [Citation(s) in RCA: 75] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2013] [Accepted: 06/16/2013] [Indexed: 01/02/2023] Open
Abstract
INTRODUCTION The use of metal-on-metal (MoM) total hip arthroplasty (THA) increased in the last decades. A release of metal products (i.e. particles, ions, metallo-organic compounds) in these implants may cause local and/or systemic adverse reactions. Metal ion concentrations in body fluids are surrogate measures of metal exposure. OBJECTIVE To systematically summarize and critically appraise published studies concerning metal ion concentrations after MoM THA. METHODS Systematic review of clinical trials (RCTs) and epidemiological studies with assessment of metal ion levels (cobalt, chromium, titanium, nickel, molybdenum) in body fluids after implantation of metalliferous hip replacements. Systematic search in PubMed and Embase in January 2012 supplemented by hand search. Standardized abstraction of pre- and postoperative metal ion concentrations stratified by type of bearing (primary explanatory factor), patient characteristics as well as study quality characteristics (secondary explanatory factors). RESULTS Overall, 104 studies (11 RCTs, 93 epidemiological studies) totaling 9.957 patients with measurement of metal ions in body fluids were identified and analyzed. Consistently, median metal ion concentrations were persistently elevated after implantation of MoM-bearings in all investigated mediums (whole blood, serum, plasma, erythrocytes, urine) irrespective of patient characteristics and study characteristics. In several studies very high serum cobalt concentrations above 50 µg/L were measured (detection limit typically 0.3 µg/L). Highest metal ion concentrations were observed after treatment with stemmed large-head MoM-implants and hip resurfacing arthroplasty. DISCUSSION Due to the risk of local and systemic accumulation of metallic products after treatment with MoM-bearing, risk and benefits should be carefully balanced preoperatively. The authors support a proposed "time out" for stemmed large-head MoM-THA and recommend a restricted indication for hip resurfacing arthroplasty. Patients with implanted MoM-bearing should receive regular and standardized monitoring of metal ion concentrations. Further research is indicated especially with regard to potential systemic reactions due to accumulation of metal products.
Collapse
Affiliation(s)
- Albrecht Hartmann
- University Hospital Carl Gustav Carus Dresden, University Centre for Orthopaedics and Trauma Surgery, Dresden, Germany
| | - Franziska Hannemann
- University Hospital Carl Gustav Carus Dresden, University Centre for Orthopaedics and Trauma Surgery, Dresden, Germany
- University Hospital Carl Gustav Carus Dresden, Centre for Evidence-Based Health Care, Dresden, Germany
| | - Jörg Lützner
- University Hospital Carl Gustav Carus Dresden, University Centre for Orthopaedics and Trauma Surgery, Dresden, Germany
| | - Andreas Seidler
- Dresden University of Technology, Occupational and Social Medicine, Dresden, Germany
| | - Hans Drexler
- University Erlangen-Nuremberg, Occupational, Social and Environmental Medicine, Erlangen, Germany
| | - Klaus-Peter Günther
- University Hospital Carl Gustav Carus Dresden, University Centre for Orthopaedics and Trauma Surgery, Dresden, Germany
| | - Jochen Schmitt
- University Hospital Carl Gustav Carus Dresden, Centre for Evidence-Based Health Care, Dresden, Germany
- Dresden University of Technology, Occupational and Social Medicine, Dresden, Germany
| |
Collapse
|
48
|
Abstract
OBJECTIVES To quantify and compare peri-acetabular bone mineral density (BMD) between a monoblock acetabular component using a metal-on-metal (MoM) bearing and a modular titanium shell with a polyethylene (PE) insert. The secondary outcome was to measure patient-reported clinical function. METHODS A total of 50 patients (25 per group) were randomised to MoM or metal-on-polyethlene (MoP). There were 27 women (11 MoM) and 23 men (14 MoM) with a mean age of 61.6 years (47.7 to 73.2). Measurements of peri-prosthetic acetabular and contralateral hip (covariate) BMD were performed at baseline and at one and two years' follow-up. The Western Ontario and McMaster Universities osteoarthritis index (WOMAC), University of California, Los Angeles (UCLA) activity score, Harris hip score, and RAND-36 were also completed at these intervals. RESULTS At two years, only zone 1 showed a loss in BMD (-2.5%) in MoM group compared with a gain in the MoP group (+2.2%). Zone 2 showed loss in both groups (-2.2% for MoM; -3.9% for MoP) and zones 3 and 4 a gain in both groups (+0.1% for MoM; +3.3% for MoP). No other between-group differences were detected. When adjusting for BMD of the contralateral hip, no differences in BMD were observed. The only significant differences in functional scores at two years were higher UCLA activity (7.3 (sd 1.2) vs 6.1 (sd 1.5); p = 0.01) and RAND-36 physical function (82.1 (sd 13.0) vs 64.5 (sd 26.4); p = 0.02) for MoM bearings versus MoP. One revision was performed in the MoM group, for aseptic acetabular loosening at 11 months. CONCLUSIONS When controlling for systemic BMD, there were no significant differences between MoM and MoP groups in peri-acetabular BMD. However, increasing reports of adverse tissue reactions with large head MoM THR have restricted the use of the monoblock acetabular component to resurfacing only.
Collapse
Affiliation(s)
- L Gauthier
- Ottawa Hospital, Divisionof Orthopaedic Surgery, University of Ottawa, 501Smyth Road Suite 5004, Ottawa, Ontario, K1H8L6, Canada
| | | | | |
Collapse
|
49
|
Schröck K, Schneider H, Lutz J, Hacker MC, Mändl S, Kamprad M, Schulz-Siegmund M. Cytocompatibility of nitrogen plasma ion immersed medical cobalt-chromium alloys. J Biomed Mater Res A 2013; 102:1744-54. [DOI: 10.1002/jbm.a.34842] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2013] [Revised: 05/30/2013] [Accepted: 06/05/2013] [Indexed: 01/11/2023]
Affiliation(s)
- Kathleen Schröck
- Translational Centre for Regenerative Medicine (TRM), Universität Leipzig; 04103 Leipzig Germany
- Pharmaceutical Technology, Institute of Pharmacy; Universität Leipzig; 04317 Leipzig Germany
| | - Heike Schneider
- Translational Centre for Regenerative Medicine (TRM), Universität Leipzig; 04103 Leipzig Germany
| | - Johanna Lutz
- Translational Centre for Regenerative Medicine (TRM), Universität Leipzig; 04103 Leipzig Germany
- Leibniz-Institut für Oberflächenmodifizierung e.V. (IOM); 04318 Leipzig Germany
| | - Michael C. Hacker
- Pharmaceutical Technology, Institute of Pharmacy; Universität Leipzig; 04317 Leipzig Germany
| | - Stephan Mändl
- Leibniz-Institut für Oberflächenmodifizierung e.V. (IOM); 04318 Leipzig Germany
| | - Manja Kamprad
- Institute of Clinical Immunology and Transfusion Medicine, University Hospital Leipzig; 04103 Leipzig Germany
| | | |
Collapse
|
50
|
Jantzen C, Jørgensen HL, Duus BR, Sporring SL, Lauritzen JB. Chromium and cobalt ion concentrations in blood and serum following various types of metal-on-metal hip arthroplasties: a literature overview. Acta Orthop 2013; 84:229-36. [PMID: 23594249 PMCID: PMC3715816 DOI: 10.3109/17453674.2013.792034] [Citation(s) in RCA: 62] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Widely different metal ion concentrations in blood and serum have been reported with metal-on-metal (MoM) implants. We reviewed the literature on blood and serum ion concentrations of chromium (Cr) and cobalt (Co) following various MoM hip arthroplasties. METHODS Studies were searched for in the Medline database, Embase, and the Cochrane Database of Systematic Reviews. Highest mean or median ion concentrations of Cr and Co after a minimum of 1 year of follow-up were extracted and grouped according to sample- and articulation type, and average values were calculated. RESULTS 43 studies were included and 16 different MoM implants were identified. For the different types of bearings, average ion concentrations and range were calculated from the mean or median ion concentration. The average Cr concentration ranged between 0.5 and 2.5 μg/L in blood and between 0.8 and 5.1 μg/L in serum. For Co, the range was 0.7-3.4 μg/L in blood and 0.3-7.5 μg/L in serum. INTERPRETATION When the average blood ion concentrations calculated for the different implants, together with the concentrations measured in the individual studies, were compared with the upper acceptable limit for Cr and Co in blood, no clear pattern was recognized. Furthermore, we were unable to detect any clear difference in ion concentrations between different types of implants (THA and resurfacing).
Collapse
Affiliation(s)
| | - Henrik L Jørgensen
- Clinical Biochemistry, Bispebjerg Hospital, University of Copenhagen, Copenhagen, Denmark
| | | | | | | |
Collapse
|