1
|
Antoniades S, McGoldrick NP, Meermans G, Beaulé PE, Grammatopoulos G. Contemporary, non-navigation, cup orientation techniques improve accuracy and eliminate differences seen between the anterior and posterior approach in THA. Hip Int 2023; 33:977-984. [PMID: 36852719 DOI: 10.1177/11207000231156543] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/01/2023]
Abstract
BACKGROUND This study aimed to: (1) Determine the ability to achieve the surgeons' desired cup orientation, without navigation, using contemporary measures with the anterior- (AA) and posterior- approaches (PA); and (2) assess whether surgical approach is associated with cup orientation accuracy, as previously reported, when contemporary measures are used. METHODS A prospective, 2-centre, multi-surgeon study of 400 THAs (200 AA; 200 PA) was performed. Intraoperative radiographs were obtained with the AA. A digital inclinometer and 3-point pelvic support were used with the PA. With the PA, intraoperative cup inclination at impaction was recorded. Radiographic inclination/anteversion (RI/RA) was measured from intraoperative radiographs (AA-only) and from postoperative radiographs for all cases. Optimum inclination/anteversion was defined as 40°/20° (±10°). The difference between intra- and postoperative orientations allowed for determination of the difference in pelvic position at impaction. RESULTS Optimum RI and RA were achieved in 91.3% (n = 365) and 92% (n = 368) of cases respectively. Optimum cup orientation was detected in 84% of cases (n = 336). There was equivalent ability to achieve cup orientation between approaches (AA: 82.5% vs. PA: 85.5%; p = 0.41). The use of an inclinometer in the PA was associated with a smaller variability of inclination at implantation (10° vs. 14°) and counteracted the greater difference in pelvic position (4.4° vs. 2.1°) seen with the PA. CONCLUSIONS Over 80% of cases can have optimum orientation without navigation, using simple, cheap contemporary measures. Such measures eliminate differences between approaches, related to patient position. Narrower implantation angles will further reduce variability in cup orientation achieved.
Collapse
Affiliation(s)
| | - Niall P McGoldrick
- Division of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, ON, Canada
| | - Geert Meermans
- Department of Orthopaedics, Bravis Hospital, Bergen op Zoom, The Netherlands
| | - Paul E Beaulé
- Division of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, ON, Canada
| | | |
Collapse
|
2
|
Tsurumi Y, Hagiwara S, Horikoshi T, Yokota H, Kurosawa R, Matsumoto K, Masuda Y, Kawarai Y, Nakamura J, Eguchi Y, Orita S, Ohtori S. Leg position effects on the femoral neurovascular bundle location during a direct anterior approach total hip arthroplasty: a radiographic study. BMC Musculoskelet Disord 2023; 24:824. [PMID: 37858083 PMCID: PMC10585724 DOI: 10.1186/s12891-023-06947-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Accepted: 10/08/2023] [Indexed: 10/21/2023] Open
Abstract
BACKGROUND Femoral neurovascular injury is a serious complication in a direct anterior approach (DAA) total hip arthroplasty. However, dynamic neurovascular bundle location changes during the approach were not examined. Thus, this study aimed to analyze the effects of leg position on the femoral neurovascular bundle location using magnetic resonance imaging (MRI). METHODS This study scanned 30 healthy volunteers (15 males and 15 females) with 3.0T MRI in a supine and 30-degree hip extension position with the left leg in a neutral rotation position and the right leg in a 45-degree external extension position. The minimum distance from the edge of the anterior acetabulum to the femoral nerve (dFN), artery, and vein were measured on axial T1-weighted images at the hip center level, as well as the angle to the horizontal line of the femoral nerve (aFN), artery (aFA), and vein from the anterior acetabulum. RESULTS The dFN in the supine position with external rotation was significantly larger than supine with neutral and extension with external rotation position (20.7, 19.5, and 19.0; p = 0.031 and 0.012, respectively). The aFA in supine with external rotation was significantly larger than in other postures (52.4°, 34.2°, and 36.2°, p < 0.001, respectively). The aFV in supine with external rotation was significantly larger than in supine with a neutral position (52.3° versus 47.7°, p = 0.037). The aFN in supine and external rotation was significantly larger than other postures (54.6, 38.2, and 33.0, p < 0.001, respectively). CONCLUSIONS This radiographic study revealed that the leg position affected the neurovascular bundle location. These movements can be the risk of direct neurovascular injury or traction.
Collapse
Affiliation(s)
- Yousuke Tsurumi
- Department of Orthopaedics Surgery, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba, 260-8670, Japan
| | - Shigeo Hagiwara
- Department of Orthopaedics Surgery, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba, 260-8670, Japan.
| | - Takuro Horikoshi
- Department of Radiology, Chiba University Hospital, Chiba University Hospital, 1-8-1 Inohana, Chuo-ku, Chiba, 260-8670, Japan
| | - Hajime Yokota
- Department of Diagnostic Radiology and Radiation Oncology, Graduate School of Medicine, Chiba University, Chiba University Hospital, 1-8-1 Inohana, Chuo-ku, Chiba, 260-8670, Japan
| | - Ryuna Kurosawa
- Department of Radiology, Chiba University Hospital, Chiba University Hospital, 1-8-1 Inohana, Chuo-ku, Chiba, 260-8670, Japan
| | - Koji Matsumoto
- Department of Radiology, Chiba University Hospital, Chiba University Hospital, 1-8-1 Inohana, Chuo-ku, Chiba, 260-8670, Japan
| | - Yoshitada Masuda
- Department of Radiology, Chiba University Hospital, Chiba University Hospital, 1-8-1 Inohana, Chuo-ku, Chiba, 260-8670, Japan
| | - Yuya Kawarai
- Department of Orthopaedics Surgery, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba, 260-8670, Japan
| | - Junichi Nakamura
- Department of Orthopaedics Surgery, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba, 260-8670, Japan
| | - Yawara Eguchi
- Department of Orthopaedics Surgery, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba, 260-8670, Japan
| | - Sumihisa Orita
- Department of Orthopaedics Surgery, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba, 260-8670, Japan
| | - Seiji Ohtori
- Department of Orthopaedics Surgery, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba, 260-8670, Japan
| |
Collapse
|
3
|
Heinz K, Nowack D, von Eisenhart-Rothe R, Wassilew G, Matziolis G, Brodt S. "Koehlers teardrop is not a reliable landmark for assessing the centre of rotation after Total hip arthroplasty" - a retrospective radiological study. Arch Orthop Trauma Surg 2023; 143:5671-5676. [PMID: 37099164 PMCID: PMC10449955 DOI: 10.1007/s00402-023-04859-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Accepted: 03/25/2023] [Indexed: 04/27/2023]
Abstract
PURPOSE Various anatomical landmarks have become established in radiography for the assessment of cup positioning after total hip arthroplasty (THA). The most important one is Koehler's teardrop figure (KTF). However, there is a lack of data on the validity of this landmark, which is widely used clinically for assessing the centre of rotation of the hip. METHOD A retrospective measurement of the lateral and cranial distance of the KTF to the centre of hip rotation was performed on the basis of 250 X-ray images of patients who had undergone THA. In addition, the dependence of these distances on pelvic tilt was determined in 16 patients by means of virtual X-ray projections based on pelvic CTs. RESULTS It was shown that the distance of the KTF from the centre of hip rotation in the horizontal plane is gender-dependent (men: 42.8 ± 6.0 mm vs. women: 37.4 ± 4.7 mm; p < 0.001) and age-dependent (Pearson correlation - 0.114; p < 0.05). Furthermore, the vertical and horizontal distances are subject to variation depending on height (Pearson correlation 0.14; p < 0.05 and 0.40; p < 0.001, respectively) and weight (Pearson correlation 0.158; p < 0.05). The distance between the KTF and the centre of hip rotation varies slightly depending on pelvic tilt. CONCLUSION The KTF is not a sufficiently valid landmark for assessing the centre of rotation after THA. It is influenced by many different disturbance variables. However, it is largely robust against changes in pelvic tilt, so that it can be used as a reference point when comparing different intraindividual radiographs to assess the change in the centre of rotation due to implantation or to detect cup migration.
Collapse
Affiliation(s)
- Kristian Heinz
- Orthopaedic Department, Jena Universitiy Hospital, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany.
| | - Dimitri Nowack
- Orthopaedic Department, Jena Universitiy Hospital, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany
| | | | - Georgi Wassilew
- Orthopaedic Department, Greifswald Universitiy, Greifswald, Germany
| | - Georg Matziolis
- Orthopaedic Department, Jena Universitiy Hospital, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany
| | - Steffen Brodt
- Orthopaedic Department, Jena Universitiy Hospital, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany
| |
Collapse
|
4
|
Kamihata S, Ando W, Takao M, Hamada H, Uemura K, Sugano N. Effect of hip flexion contracture on the pelvic sagittal tilt in the supine position: A retrospective case-series study. Mod Rheumatol 2023; 33:1052-1057. [PMID: 36083017 DOI: 10.1093/mr/roac110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Revised: 07/20/2022] [Accepted: 08/30/2022] [Indexed: 11/14/2022]
Abstract
OBJECTIVES The functional pelvic plane, which adopts the natural pelvic sagittal tilt in the supine position, is a good reference for determining the cup angle in total hip arthroplasty. However, hip flexion contracture may change pelvic tilt postoperatively by the release of contracture. This study investigated the influence of hip flexion contracture on pelvic sagittal tilt in the supine position. METHODS This study included 300 patients who underwent primary unilateral total hip arthroplasty. We divided the participants into two groups: with a preoperative hip extension angle of <0° (hip flexion contracture group) and without (non-contracture group). The pelvic sagittal tilt and femoral flexion angle were investigated using computed tomography or pelvic radiographs performed preoperatively and postoperatively. RESULTS The femoral flexion angle had significantly reduced postoperatively in the hip flexion contracture group but remained unchanged in the non-contracture group. The preoperative and postoperative pelvic sagittal tilt showed no significant differences between the two groups up to 1 year postoperatively. CONCLUSIONS The influence of hip flexion contracture on the pelvic sagittal tilt in the supine position was minimal. The functional pelvic plane in the supine position could be a good reference to ascertain the cup orientation, even in hip flexion contracture cases.
Collapse
Affiliation(s)
- Satoshi Kamihata
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Wataru Ando
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Masaki Takao
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Suita, Japan
| | - Hidetoshi Hamada
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Keisuke Uemura
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Suita, Japan
| | - Nobuhiko Sugano
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| |
Collapse
|
5
|
Baghdadi J, Alkhateeb S, Roth A, Jäger M, Alkhateeb S, Landgraeber S, Serong S, Haversath M, vonWasen A, Windhagen H, Flörkemeier T, Budde S, Kubilay J, Noll Y, Delank KS, Baghdadi J, Willburger R, Dücker M, Wilke A, Hütter F, Jäger M. Cup positioning and its effect on polyethylene wear of vitamin E- and non-vitamin E-supplemented liners in total hip arthroplasty: radiographic outcome at 5-year follow-up. Arch Orthop Trauma Surg 2023; 143:1679-1688. [PMID: 35397656 PMCID: PMC9957849 DOI: 10.1007/s00402-022-04424-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Accepted: 03/10/2022] [Indexed: 11/28/2022]
Abstract
BACKGROUND Aseptic loosening remains a challenging problem after total hip arthroplasty. Accurate cup placement and supplementation of antioxidants in acetabular liners might reduce material failure rates. The aim of this study is to assess the effect of the cup position on the wear behaviour of UHMWPE-XE and UHMWPE-X liners in vivo using virtual radiographs. METHODS We conducted a prospective, randomized, controlled, multicenter trial. Clinical data of 372 probands were analyzed. Anteroposterior pelvic X-rays of 324 patients immediately postoperatively and after 1 and 5 years were evaluated by the RayMatch® analysis software regarding cup position and wear behaviour. RESULTS Mean cup anteversion was 20.3° (± 7.4) and inclination was 41.9° (± 7.0) postoperatively. 62.3% of all patients had an anteversion and inclination within the Lewinnek safe zone. Anterior and anterolateral approaches led to significantly higher cup anteversion compared to lateral approaches (27.3° ± 5.5; 20.9° ± 7.2; 17.5° ± 6.6; p < 0.001 and p = 0.001, respectively). Mean anteversion increased to 24.6° (± 8.0) after 1 year (p < 0.001). Only one revision occurred because of implant dislocation. Wear rates from UHMWPE-X and UHMWPE-XE did not differ significantly. Anteversion angles ≥ 25° correlated to increased polyethylene wear (23.7 µm/year ± 12.8 vs. 31.1 µm/year ± 22.8, p = 0.012) and this was amplified when inclination angles were ≥ 50° (23.6 µm/year ± 12.8 vs. 38.0 µm/year ± 22.7, p = 0.062). CONCLUSION Anterior approaches lead to the highest inaccuracy of cup placement, but cup positioning outside the Lewinnek safe zone does not necessarily cause higher dislocation rates. Moreover, mean anteversion increased by approximately four degrees within the first year after operation, which is expected to be functional due to a regularization of pelvic tilt after intervention. Mid-term wear rates of UHMWPE-X and UHMWPE-XE liners are comparable, but steep cup positions lead to significantly increased polyethylene wear. In summary, a re-evaluation of target zones for intraoperative cup positioning might be considered. In the long-term reduced oxidative embrittlement could lead to superior wear behaviour of vitamin E-blended liners.
Collapse
Affiliation(s)
- Josef Baghdadi
- Department of Orthopedics, Trauma, and Reconstructive Surgery, University Hospital Halle (Saale), Halle (Saale), Germany.
| | - Shareef Alkhateeb
- Department of Orthopedics, Trauma and Reconstructive Surgery, Marienhospital Mülheim an Der Ruhr, Chair of Orthopedics and Trauma Surgery, University of Duisburg–Essen, Essen, Germany
| | | | | | - Marcus Jäger
- Department of Orthopedics, Trauma and Reconstructive Surgery, Marienhospital Mülheim an Der Ruhr, Chair of Orthopedics and Trauma Surgery, University of Duisburg–Essen, Essen, Germany
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Louette S, Wignall A, Pandit H. Spinopelvic Relationship and Its Impact on Total Hip Arthroplasty. Arthroplast Today 2022; 17:87-93. [PMID: 36042938 PMCID: PMC9420424 DOI: 10.1016/j.artd.2022.07.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 06/21/2022] [Accepted: 07/04/2022] [Indexed: 11/27/2022] Open
Abstract
The dynamic, complex interaction among the spine, pelvis, and hip is often underappreciated, yet understanding it is vital for both arthroplasty and spinal surgeons. There is an increasing incidence of degenerative hip and spinal pathologies as a result of the ageing population. Furthermore, hip pathology can cause spine pathology and vice versa through “hip-spine” and “spine-hip syndrome.” Consequently, total hip arthroplasty (THA) and spinal fusion surgery, which both affect spinopelvic mobility, are also on the rise. Alteration in spinopelvic motion can affect the orientation of the acetabulum and, therefore, implant positioning in THA, leading to complications such as dislocation, impingement, aseptic loosening, and wear of components. This makes it imperative to assess spinopelvic motion and pelvic tilt prior to patients undergoing THA. In this paper, we explore how the surgeon should proceed to reduce risk of component malalignment, as well as the role of navigation systems in acetabular cup positioning.
Collapse
|
7
|
Kaiser M, Renkawitz T, Benditz A, König M, Thieme M, Weber M. Pelvic tilt impacts cup orientation on CT: how accurate is the gold standard? ACTA RADIOLOGICA (STOCKHOLM, SWEDEN : 1987) 2022; 63:698-705. [PMID: 33982602 DOI: 10.1177/02841851211009466] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND Computed tomography (CT) is the gold standard for the accurate measurement of cup inclination and anteversion in total hip arthroplasty (THA). However, functional cup position strongly depends on the tilt of the pelvis and thus pelvic tilt in the supine position on the CT table harbors the risk of misinterpretation. PURPOSE To evaluate the influence of pelvic tilt on cup measurements in postoperative CT scans. MATERIAL AND METHODS This is a secondary outcome analysis of a prospective study. In 123 patients undergoing THA, anatomic cup inclination and anteversion as measured on postoperative 3D-CT scans were compared between: (i) the anterior pelvic plane (APP) resembling neutral pelvic tilt; and (ii) the coronal plane representing the standard planes on CT. Furthermore, the effect of the variation on cup positions within Lewinnek's safe zone in relation to the applied reference plane was assessed. RESULTS Mean pelvic tilt in supine position was -3.5° ± 5.6°. This resulted in a mean difference for anteversion between APP und coronal plane of 2.1° ± 3.7° and of 2.1° ± 1.9° for cup inclination, respectively. The change varied up to 20.2° for cup inclination and up 12.2° for cup anteversion. The overall conversion rate for inclination and/or anteversion regarding Lewinnek's safe zone was high at 23.6% (29/123). CONCLUSION Pelvic tilt affects cup orientation on CT scans depending on the applied reference plane. Standard CT planes should be corrected regarding pelvic tilt before measurements to avoid errors in measurement.
Collapse
Affiliation(s)
- Moritz Kaiser
- Department of Orthopaedic Surgery, Regensburg University Medical Center, Bad Abbach, Germany
| | - Tobias Renkawitz
- Department of Orthopaedic Surgery, Regensburg University Medical Center, Bad Abbach, Germany
| | - Achim Benditz
- Department of Orthopaedic Surgery, Regensburg University Medical Center, Bad Abbach, Germany
| | - Matthias König
- Department of Orthopaedic Surgery, Regensburg University Medical Center, Bad Abbach, Germany
| | - Max Thieme
- Department of Orthopaedic Surgery, Regensburg University Medical Center, Bad Abbach, Germany
| | - Markus Weber
- Department of Orthopaedic Surgery, Regensburg University Medical Center, Bad Abbach, Germany
| |
Collapse
|
8
|
Iturriaga CR, Jung B, Mont MA, Rasquinha VJ, Boraiah S. Variability in Acetabular Component Position in Patients Undergoing Direct Anterior Approach Total Hip Arthroplasty Who Have Concomitant Spine Pathology. J Arthroplasty 2022; 37:501-506.e1. [PMID: 34822930 DOI: 10.1016/j.arth.2021.11.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Revised: 11/11/2021] [Accepted: 11/16/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Hip instability following total hip arthroplasty (THA) can be a major cause of revision surgery. Physiological patient position impacts acetabular anteversion and abduction, and influences the functional component positioning. Osteoarthritis of the spine leads to abnormal spinopelvic biomechanics and motion, but there is no consensus on the degree of component variability for THAs performed by anterior approach. Therefore, we sought to present guidelines for changes in acetabular component positioning between supine and standing positions for patients undergoing primary THA by a uniform anterior approach. METHODS Perioperative patient radiographs of the pelvis and lumbar spine were collected. Images were used to determine acetabular component positioning and degree of coexisting spinal pathology, categorized as a Lane Grade (LG). Final analysis of variance was performed on a sample size of 643 anterior primary THAs. RESULTS From supine to standing position, as the severity of lumbar pathology increased the change in anteversion also increased (LG:0 = -0.11° ± 4.65°, LG:1 = 2.02° ± 4.09°, LG:2-3 = 5.78° ± 5.72°, P < .001). The mean supine anteversion in patients with absent lumbar pathology was 19.72° ± 5.05° and was lower in patients with worsening lumbar pathology (LG:1 = 18.25° ± 4.81°, LG:2-3 = 16.73° ± 5.28°, P < .001). CONCLUSION Patients undergoing primary THA by anterior approach with worsening spinal pathology have larger increases in component anteversion when transitioning from supine to standing positions. Consideration should be given to this expected variability when placing the patient's acetabular component.
Collapse
Affiliation(s)
- Cesar R Iturriaga
- Department of Orthopaedic Surgery, Long Island Jewish Medical Center, Northwell Health, New Hyde Park, NY; Department of Orthopaedic Surgery, Plainview Hospital, Northwell Health, Plainview, NY
| | - Byeongho Jung
- Donald and Barbara Zucker School of Medicine, Hofstra University, Hempstead, NY
| | - Michael A Mont
- Department of Orthopaedic Surgery, Lenox Hill Hospital, Northwell Health, New York, NY
| | - Vijay J Rasquinha
- Department of Orthopaedic Surgery, Long Island Jewish Medical Center, Northwell Health, New Hyde Park, NY
| | - Sreevathsa Boraiah
- Department of Orthopaedic Surgery, Long Island Jewish Medical Center, Northwell Health, New Hyde Park, NY
| |
Collapse
|
9
|
Nishihara S, Hayashida K. Comparison between freehand technique and computed tomography-based navigation in acetabular cup placement through direct anterior approach for total hip arthroplasty. Arch Orthop Trauma Surg 2022; 142:323-329. [PMID: 33929597 DOI: 10.1007/s00402-021-03920-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Accepted: 04/19/2021] [Indexed: 01/17/2023]
Abstract
INTRODUCTION In total hip arthroplasty (THA), improper cup orientation can result in dislocation, early excessive polyethylene wear, and pain following THA. The supine position during THA provides a more reproducible functional pelvic position than the lateral decubitus position and may allow freehand cup placement as reliable as that obtained by computer navigation. The purpose of this study was to investigate the accuracy of freehand cup placement through a supine direct anterior approach (DAA) compared with computed tomography (CT)-based navigation. MATERIALS AND METHODS The same surgeon performed primary cementless THA through the DAA in 144 supine patients. Seventy-two patients underwent freehand cup placement with standard mechanical guidance-oriented radiographic target cup positioning, and 72 underwent placement with CT-based navigation guidance. Using three-dimensional templating software, the study group calculated cup inclination and anteversion on postoperative CT scans. RESULTS The navigation method resulted in a significantly smaller deviation of inclination from the target (p < 0.05); the difference in anteversion was not significant. In addition, the navigation method resulted in significantly fewer cups placed ± 10° outside the target position (0% for inclination, 0% for anteversion) than did the freehand procedure (26% for inclination, 25% for anteversion) (p < 0.0001). CONCLUSIONS Freehand cup placement is less reliable even in the supine position. Use of a CT-based navigation system can significantly improve cup positioning in THA through the DAA by reducing the incidence of outliers.
Collapse
Affiliation(s)
- Shunsaku Nishihara
- Department of Orthopaedic Surgery, Daini Osaka Police Hospital, 2-6-40 Karasugatsuji, Tennouji-ku, Osaka, 543-8922, Japan.
| | - Kenji Hayashida
- Department of Orthopaedic Surgery, Daini Osaka Police Hospital, 2-6-40 Karasugatsuji, Tennouji-ku, Osaka, 543-8922, Japan
| |
Collapse
|
10
|
Bhanushali A, Chimutengwende-Gordon M, Beck M, Callary SA, Costi K, Howie DW, Solomon LB. The variation in hip stability measurements between supine and standing radiographs of dysplastic hips. Bone Joint J 2021; 103-B:1662-1668. [PMID: 34719274 DOI: 10.1302/0301-620x.103b11.bjj-2020-2519.r2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS The aims of this study were to compare clinically relevant measurements of hip dysplasia on radiographs taken in the supine and standing position, and to compare Hip2Norm software and Picture Archiving and Communication System (PACS)-derived digital radiological measurements. METHODS Preoperative supine and standing radiographs of 36 consecutive patients (43 hips) who underwent periacetabular osteotomy surgery were retrospectively analyzed from a single-centre, two-surgeon cohort. Anterior coverage (AC), posterior coverage (PC), lateral centre-edge angle (LCEA), acetabular inclination (AI), sharp angle (SA), pelvic tilt (PT), retroversion index (RI), femoroepiphyseal acetabular roof (FEAR) index, femoroepiphyseal horizontal angle (FEHA), leg length discrepancy (LLD), and pelvic obliquity (PO) were analyzed using both Hip2Norm software and PACS-derived measurements where applicable. RESULTS Analysis of supine and standing radiographs resulted in significant variation for measurements of PT (p < 0.001) and AC (p = 0.005). The variation in PT correlated with the variation in AC in a limited number of patients (R2 = 0.378; p = 0.012). CONCLUSION The significant variation in PT and AC between supine and standing radiographs suggests that it may benefit surgeons to have both radiographs when planning surgical correction of hip dysplasia. We also recommend using PACS-derived measurements of AI and SA due to the poor interobserver error on Hip2Norm. Cite this article: Bone Joint J 2021;103-B(11):1662-1668.
Collapse
Affiliation(s)
- Ameya Bhanushali
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia
| | | | - Martin Beck
- Department of Orthopaedics and Trauma, Orthopaedic Clinic Lucerne AG, Lucerne, Switzerland
| | - Stuart Adam Callary
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia.,Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, Australia
| | - Kerry Costi
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia
| | - Donald W Howie
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia.,Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, Australia
| | - Lucian Bogdan Solomon
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia.,Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, Australia
| |
Collapse
|
11
|
Yoshino K, Hagiwara S, Nakamura J, Horikoshi T, Yokota H, Shimokawa K, Matsumoto K, Shiko Y, Kawasaki Y, Ohtori S. The distance between the femoral nerve and anterior acetabulum is significantly shorter in hip osteoarthritis than in non-osteoarthritis hip. BMC Musculoskelet Disord 2021; 22:416. [PMID: 33952226 PMCID: PMC8101116 DOI: 10.1186/s12891-021-04295-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Accepted: 04/21/2021] [Indexed: 11/27/2022] Open
Abstract
Background The appropriate position of retractors to minimize the risk of femoral nerve palsy remains uncertain. The purpose of this imaging study was to evaluate the distance between the femoral nerve (FN) and anterior acetabulum (AA) in hip osteoarthritis (OA). Methods Forty-one patients with unilateral hip OA underwent magnetic resonance imaging. Three measurement levels were defined and the minimum distance between the femoral nerve (FN) margin and anterior acetabulum (AA) rim was measured on axial T1-weighted images on the OA and normal sides at each level, with reference to an advanced neurography view. The cross-sectional area (CSA) of the iliopsoas muscle was also measured at each level bilaterally by three observers. Distances and CSAs were compared between the OA and normal side. Multiple regression analysis was performed to identify variables associated with the distance in OA. Results The mean minimum FN to AA distances in OA were 19.4 mm at the top of the anterior inferior iliac spine (AIIS), 24.3 mm at the bottom of the AIIS, and 21.0 mm at the tip of the greater trochanter. These distances were significantly shorter than in normal hips at the top and bottom of the AIIS, with mean differences of 1.6 and 5.8 mm, respectively (p = 0.012, p < 0.001). CSAs of the iliopsoas in OA were significantly smaller at all levels (all p < 0.001), with reductions of 10.5 to 17.9%. The CSA of the iliopsoas at the bottom of the AIIS was associated with the FN to AA distance at the same level (p = 0.026). Interobserver reliabilities for measurements were very good to perfect (intraclass correlation coefficients 0.897 to 0.966). Conclusions To minimize the risk of femoral nerve palsy, surgeons should consider the change of the femoral nerve to anterior acetabulum distance in osteoarthritic hip surgery.
Collapse
Affiliation(s)
- Kensuke Yoshino
- Department of Orthopaedic Surgery, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba, 260-8677, Japan
| | - Shigeo Hagiwara
- Department of Orthopaedic Surgery, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba, 260-8677, Japan.
| | - Junichi Nakamura
- Department of Orthopaedic Surgery, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba, 260-8677, Japan
| | - Takuro Horikoshi
- Diagnostic Radiology and Radiation Oncology, Graduate School of Medicine, Chiba University, Chiba, Japan
| | - Hajime Yokota
- Diagnostic Radiology and Radiation Oncology, Graduate School of Medicine, Chiba University, Chiba, Japan
| | - Kenji Shimokawa
- Diagnostic Radiology and Radiation Oncology, Graduate School of Medicine, Chiba University, Chiba, Japan
| | - Koji Matsumoto
- Diagnostic Radiology and Radiation Oncology, Graduate School of Medicine, Chiba University, Chiba, Japan
| | - Yuki Shiko
- Biostatistics Section, Clinical Research Center, Chiba University Hospital, Chiba, Japan
| | - Yohei Kawasaki
- Biostatistics Section, Clinical Research Center, Chiba University Hospital, Chiba, Japan
| | - Seiji Ohtori
- Department of Orthopaedic Surgery, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba, 260-8677, Japan
| |
Collapse
|
12
|
Fischer MCM, Tokunaga K, Okamoto M, Habor J, Radermacher K. Preoperative factors improving the prediction of the postoperative sagittal orientation of the pelvis in standing position after total hip arthroplasty. Sci Rep 2020; 10:15944. [PMID: 32994419 PMCID: PMC7524714 DOI: 10.1038/s41598-020-72782-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2020] [Accepted: 09/02/2020] [Indexed: 11/09/2022] Open
Abstract
The aims of this study were to investigate if the sagittal orientation of the pelvis (SOP) in the standing position changes after total hip arthroplasty (THA) and evaluate what preoperative factors may improve the prediction of the postoperative standing SOP in the context of a patient-specific functional cup orientation. 196 primary THA patients from Japan were retrospectively selected for this study. Computed tomography imaging of the pelvis, EOS imaging of the lower body and lateral radiographs of the lumbar spine in the standing position were taken preoperatively. Common biometrics and preoperative Harris Hip Score were recorded. The EOS imaging in the standing position was repeated three months following THA. A 3D/2.5D registration process was used to determine the standing SOP. Thirty-three preoperative biometric, morphological and functional parameters were measured. Important preoperative parameters were identified that significantly improve the prediction of the postoperative standing SOP by using multiple linear LASSO regression. On average, the SOP changed significantly (p < 0.001) between the preoperative and postoperative standing position three months after THA by 3° ± 4° in the posterior direction. The age, standing lumbar lordosis angle (LLA) and preoperative supine and standing SOP significantly (p < 0.001) improve the prediction of the postoperative standing SOP. The linear regression model for the prediction of the postoperative standing SOP is significantly (p < 0.001) improved by adding the parameters preoperative standing SOP and LLA, in addition to the preoperative supine SOP, reducing the root mean square error derived from a leave-one-out cross-validation by more than 1°. The mean standing SOP in Japanese patients changes already three months after THA in comparison to the preoperative value. The preoperative factors age, LLA, supine and standing SOP can significantly improve the prediction of the postoperative standing SOP and should be considered within the preoperative planning process of a patient-specific functional cup orientation.
Collapse
Affiliation(s)
- Maximilian C M Fischer
- Chair of Medical Engineering, Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany.
| | - Kunihiko Tokunaga
- Niigata Hip Joint Center, Kameda Daiichi Hospital, Niigata City, Japan
| | - Masashi Okamoto
- Department of Radiology, Kameda Daiichi Hospital, Niigata City, Japan
| | - Juliana Habor
- Chair of Medical Engineering, Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany
| | - Klaus Radermacher
- Chair of Medical Engineering, Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
13
|
Widmer KH. The Impingement-free, Prosthesis-specific, and Anatomy-adjusted Combined Target Zone for Component Positioning in THA Depends on Design and Implantation Parameters of both Components. Clin Orthop Relat Res 2020; 478:1904-1918. [PMID: 32732575 PMCID: PMC7371099 DOI: 10.1097/corr.0000000000001233] [Citation(s) in RCA: 40] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2019] [Accepted: 03/04/2020] [Indexed: 01/31/2023]
Abstract
BACKGROUND Lewinnek's recommendation for orienting the cup in THA is criticized because it involves a static assessment of the safe zone and because it does not consider stem geometry. A revised concept of the safe zone should consider those factors, but to our knowledge, this has not been assessed. QUESTIONS/PURPOSES (1) To determine the shape, size, and location of target zones for combined cup and stem orientation for a straight stem/hemispheric cup THA to maximize the impingement-free ROM and (2) To determine whether and how these implant positions change as stem anteversion, neck-shaft angle, prosthetic head size and target range of movements are varied. METHODS A three-dimensional computer-assisted design model, in which design geometry was expressed in terms of parameters, of a straight stem/hemispheric cup hip prosthesis was designed, its design parameters modified systematically, and each prosthesis model was implanted virtually at predefined component orientations. Functional component orientation referencing to body planes was used: cups were abducted from 20° to 70°, and anteverted from -10° to 40°. Stems were rotated from -10° to 40° anteversion, neck-shaft angles varied from 115° to 143°, and head sizes varied from 28 to 40 mm. Hip movements up to the point of prosthetic impingement were tested, including simple flexion/extension, internal/external rotation, ab/adduction, combinations of these, and activities of daily living that were known to trigger dislocation. For each combination of parameters, the impingement-free combined target zone was determined. Maximizing the size of the combined target zone was the optimization criterion. RESULTS The combined target zones for impingement-free cup orientation had polygonal boundaries. Their size and position in the diagram changed with stem anteversion, neck-shaft angle, head size, and target ROM. The largest target zones were at neck-shaft angles from 125° to 127°, at stem anteversions from 10° to 20°, and at radiographic cup anteversions between 17° and 25°. Cup anteversion and stem anteversion were inverse-linearly correlated supporting the combined-anteversion concept. The range of impingement-free cup inclinations depended on head size, stem anteversion, and neck-shaft angle. For a 127°-neck-shaft angle, the lowest cup inclinations that fell within the target zone were 42° for the 28-mm and 35° for the 40-mm head. Cup anteversion and combined version depended on neck-shaft angle. For head size 32-mm cup, anteversion was 6° for a 115° neck-shaft angle and 25° for a 135°-neck-shaft angle, and combined version was 15° and 34° respectively. CONCLUSIONS The shape, size, and location of the combined target zones were dependent on design and implantation parameters of both components. Changing the prosthesis design or changing implantation parameters also changed the combined target zone. A maximized combined target zone was found. It is mandatory to consider both components to determine the accurate impingement-free prosthetic ROM in THA. CLINICAL RELEVANCE This study accurately defines the hypothetical impingement-free, design-specific component orientation in THA. Transforming it into clinical precision may be the case for navigation and/or robotics, but this is speculative, and as of now, unproven.
Collapse
Affiliation(s)
- Karl-Heinz Widmer
- K.-H. Widmer, Medical Faculty University of Basel, Basel, Switzerland
| |
Collapse
|
14
|
Uemura K, Takao M, Otake Y, Koyama K, Yokota F, Hamada H, Sakai T, Sato Y, Sugano N. Reproducibility of pelvic sagittal inclination while acquiring radiographs in supine and standing postures. J Orthop Surg (Hong Kong) 2020; 27:2309499019828515. [PMID: 30798713 DOI: 10.1177/2309499019828515] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
PURPOSE Pelvic position on the sagittal plane is usually evaluated with the pelvic sagittal inclination (PSI) angle from a single radiograph. However, the reproducibility of pelvic positioning has not been investigated, and thus, the validity of measuring the PSI from a single film/time point is not understood. Herein, the reproducibility of a patient's pelvic positions in supine and standing postures was analyzed. METHODS A total of 34 patients who underwent either a pelvic osteotomy or total hip arthroplasty were enrolled in this study. Preoperative radiographs in both supine and standing postures were acquired twice (first X-ray and second X-ray) within 6 months; preoperative computed tomography (CT) images of the full pelvis were also acquired in a supine posture (preop-CT). To eliminate measurement variability, each PSI was automatically measured from radiographs and CT images through the use of CT segmentation and landmark localization followed by intensity-based 2D-3D registration. The absolute difference of PSI among each image was calculated and the intra-class correlation coefficient (ICC) in each posture was also analyzed. RESULTS The median absolute differences of PSI in the supine posture were 1.3° between the first and second X-rays, 1.2° between the first X-ray and preop-CT, and 1.3° between the second X-ray and preop-CT. The median absolute difference of PSI in the standing posture was 1.5°. The ICC was 0.965 (95% CI: 0.939-0.981) in supine and 0.977 (95% CI: 0.954-0.988) during standing. CONCLUSIONS Pelvic positions in supine and standing postures are reproducible. Thus, measuring the PSI from a single radiograph is reliable.
Collapse
Affiliation(s)
- Keisuke Uemura
- 1 Department of Orthopaedic Medical Engineering, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan
| | - Masaki Takao
- 1 Department of Orthopaedic Medical Engineering, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan
| | - Yoshito Otake
- 2 Graduate School of Information Science, Nara Institute of Science and Technology, Ikoma, Nara, Japan
| | - Koki Koyama
- 2 Graduate School of Information Science, Nara Institute of Science and Technology, Ikoma, Nara, Japan
| | - Futoshi Yokota
- 2 Graduate School of Information Science, Nara Institute of Science and Technology, Ikoma, Nara, Japan
| | - Hidetoshi Hamada
- 3 Department of Orthopaedic Surgery, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan
| | - Takashi Sakai
- 3 Department of Orthopaedic Surgery, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan
| | - Yoshinobu Sato
- 2 Graduate School of Information Science, Nara Institute of Science and Technology, Ikoma, Nara, Japan
| | - Nobuhiko Sugano
- 1 Department of Orthopaedic Medical Engineering, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan
| |
Collapse
|
15
|
Total hip arthroplasty by direct anterior approach in the lateral position for the treatment of ankylosed hips. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2020; 30:993-1001. [PMID: 32185574 DOI: 10.1007/s00590-020-02655-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2019] [Accepted: 03/10/2020] [Indexed: 02/04/2023]
Abstract
OBJECTIVE To investigate the clinical efficacy of total hip arthroplasty (THA) via the direct anterior approach (DAA) for the treatment of hip ankylosis in the lateral position. METHODS A retrospective analysis was performed on the clinical data of 24 patients (39 hips) who underwent THA via the DAA in the lateral position for the treatment of hip ankylosis between January 2016 and December 2018. We performed bilateral THA for fifteen patients and unilateral THA for nine patients. Operation time, intraoperative blood loss, length of incisions, straight leg-raising time, length of postoperative hospital stay, operation-related complication, prosthesis position, radiological outcomes, postoperative pain relief (evaluated by VAS) and functional rehabilitation [evaluated by Harris hip score and range of motion (ROM)] were analyzed to determine clinical efficacy. These clinical data were compared and statistically analyzed with the clinical data of another 23 patients (28 hips) who underwent THA via the posterolateral approach (PLA) for the treatment of hip ankylosis in the lateral position. RESULTS Follow-up was performed at 12-15 months. The incision length in the DAA group and the PLA group was (11.12 ± 1.69 vs. 14.36 ± 3.42) cm, the intraoperative blood loss was (371.25 ± 120.55 vs. 396.80 ± 101.21) ml, the operation time was (122.47 ± 25.40 vs. 138.47 ± 24.45) min, the postoperative hospital stay was (9.59 ± 4.62 vs. 12.08 ± 3.58) days, and the straight leg elevation time was (9.20 ± 2.12 vs. 12.34 ± 3.25) days, respectively. The prosthesis of the two groups was in a good position: The average angle of cup anteversion in the DAA group and the PLA group was (10.76 ± 2.84 vs. 15.36 ± 3.42)°, and the average angle of cup abduction in the DAA group and the PLA group was (40.00 ± 3.45 vs. 41.21 ± 2.85)° (P > 0.05). The VAS score, ROM and Harris score at different follow-up time points were significantly improved in the two groups compared with those before surgery. In the first 3 months after surgery, the VAS score, ROM and Harris score of the DAA group were significantly better than those of the PLA group (P < 0.05), but with the extension of the follow-up time, there was no significant difference in the above indicators between the two groups (P > 0.05). One case of greater trochanteric fracture occurred in the DAA group. Two cases of hip posterior dislocations occurred in the PLA group, and no dislocations occurred after manual closed reduction and hip fixation in bed for 1 month to the last follow-up. No complications such as infection, deep vein thrombosis, fat embolism, prosthesis loosening, limb length inequality or joint dislocation were reported. CONCLUSION THA via the DAA for the treatment of hip ankylosis in the lateral position was safe and effective and had the advantage of reduced trauma, quicker recovery of hip function, lower incidence of postoperative dislocation and ability to expose the acetabulum fully and fit the prosthesis properly, providing satisfactory clinical efficacy.
Collapse
|
16
|
A new method for intraoperative assessment of leg length, sizing and placement of the components in total hip replacement. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2020; 30:689-694. [PMID: 31897710 DOI: 10.1007/s00590-019-02621-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2019] [Accepted: 12/19/2019] [Indexed: 10/25/2022]
Abstract
BACKGROUND Intraoperative radiograph of the pelvis is a well-established way to avoid misplacement/undersizing of the components and leg length discrepancy (LLD) in total hip replacement (THR). We describe a method for the obtainment and the evaluation of intraoperative radiographs with a sophisticated wireless radiographic system and a computerized digital tool originally used for preoperative templating. METHODS In this retrospective case-control study, 60 patients with unilateral hip osteoarthritis who underwent THR with intraoperative radiographic check with the conventional method (n = 30, control group) or the new method (AGFA flat panel DR14eG™/Orthosize™, n = 30, case group) were evaluated and compared for operation time, intraoperative changes in size/placement of the components and final radiological outcome (LLD, acetabular inclination and femoral offset) based on postoperative radiographs of the pelvis. RESULTS Mean operation time was lower in case group (85.3 min vs. 103.3 min, p value < 0.005), as well as mean absolute LLD (1.93 mm vs. 2.94 mm, p value = 0.242). There was a higher percentage of intraoperative changes in the offset of the prostheses' head (70% vs. 40%, p value = 0.018) and a significantly lower percentage of patients with LLD > 5 mm in the case group (0% vs. 27%, p value = 0.002). CONCLUSIONS This new method for the obtainment and assessment of intraoperative radiographs proved to be fast and assuring for keeping LLD below 5 mm in all patients.
Collapse
|
17
|
Weber M, Witzmann L, Wieding J, Grifka J, Renkawitz T, Craiovan B. Customized implants for acetabular Paprosky III defects may be positioned with high accuracy in revision hip arthroplasty. INTERNATIONAL ORTHOPAEDICS 2018; 43:2235-2243. [PMID: 30306217 DOI: 10.1007/s00264-018-4193-3] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2018] [Accepted: 10/01/2018] [Indexed: 12/18/2022]
Abstract
PURPOSE In revision hip arthroplasty, custom-made implants are one option in patients with acetabular Paprosky III defects. METHODS In a retrospective analysis, we identified 11 patients undergoing cup revision using a custom-made implant. The accuracy of the intended position of the implant was assessed on post-operative 3D CT and compared to the pre-operative 3D planning in terms of inclination, anteversion, and centre of rotation. In addition, the accuracy of post-operative plain radiographs for measuring implant position was evaluated in relation to the 3D CT standard. RESULTS We found a mean deviation between the planned and the final position of the custom-made acetabular implant on 3D CT of 3.6° ± 2.8° for inclination and of - 1.2° ± 7.0° for anteversion, respectively. Restoration of center of rotation succeeded with an accuracy of 0.3 mm ± 3.9 mm in the mediolateral (x) direction, - 1.1 mm ± 3.8 mm in the anteroposterior (y) direction, and 0.4 mm ± 3.2 mm in the craniocaudal (z) direction. The accuracy of the post-operative plain radiographs in measuring the position of the custom-made implant in relation to 3D CT was 1.1° ± 1.7° for implant inclination, - 2.6° ± 1.3° for anteversion and 1.3 mm ± 3.5 mm in the x-direction, and - 0.9 mm ± 3.8 mm in the z-direction for centre of rotation. CONCLUSION Custom-made acetabular implants can be positioned with good accuracy in Paprosky III defects according to the pre-operative planning. Plain radiographs are adequate for assessing implant position in routine follow-up.
Collapse
Affiliation(s)
- Markus Weber
- Department of Orthopaedic Surgery, Regensburg University, Medical Center, Asklepios Klinikum Bad Abbach Kaiser-Karl V.-Allee 3, 93077, Bad Abbach, Germany.
| | - Lena Witzmann
- Department of Orthopaedic Surgery, Regensburg University, Medical Center, Asklepios Klinikum Bad Abbach Kaiser-Karl V.-Allee 3, 93077, Bad Abbach, Germany
| | | | - Joachim Grifka
- Department of Orthopaedic Surgery, Regensburg University, Medical Center, Asklepios Klinikum Bad Abbach Kaiser-Karl V.-Allee 3, 93077, Bad Abbach, Germany
| | - Tobias Renkawitz
- Department of Orthopaedic Surgery, Regensburg University, Medical Center, Asklepios Klinikum Bad Abbach Kaiser-Karl V.-Allee 3, 93077, Bad Abbach, Germany
| | - Benjamin Craiovan
- Department of Orthopaedic Surgery, Regensburg University, Medical Center, Asklepios Klinikum Bad Abbach Kaiser-Karl V.-Allee 3, 93077, Bad Abbach, Germany
| |
Collapse
|
18
|
Grammatopoulos G, Gofton W, Cochran M, Dobransky J, Carli A, Abdelbary H, Gill HS, Beaulé PE. Pelvic positioning in the supine position leads to more consistent orientation of the acetabular component after total hip arthroplasty. Bone Joint J 2018; 100-B:1280-1288. [DOI: 10.1302/0301-620x.100b10.bjj-2018-0134.r1] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Aims This study aims to: determine the difference in pelvic position that occurs between surgery and radiographic, supine, postoperative assessment; examine how the difference in pelvic position influences subsequent component orientation; and establish whether differences in pelvic position, and thereafter component orientation, exist between total hip arthroplasties (THAs) performed in the supine versus the lateral decubitus positions. Patients and Methods The intra- and postoperative anteroposterior pelvic radiographs of 321 THAs were included; 167 were performed with the patient supine using the anterior approach and 154 were performed with the patient in the lateral decubitus using the posterior approach. The inclination and anteversion of the acetabular component was measured and the difference (Δ) between the intra- and postoperative radiographs was determined. The target zone was inclination/anteversion of 40°/20° (± 10°). Changes in the tilt, rotation, and obliquity of the pelvis on the intra- and postoperative radiographs were calculated from Δinclination/anteversion using the Levenberg–Marquardt algorithm. Results The mean postoperative inclination/anteversion was 40° (± 8°)/23° (± 9°) with Δinclination and/or Δanteversion > ± 10° in 74 (21%). Intraoperatively, the pelvis was anteriorly tilted by a mean of 4° (± 10°), internally rotated by a mean of 1° (± 10°) and adducted by a mean of 1° (± 5°). Having Δinclination and/or Δanteversion > ± 10° was associated with a 3.5 odds ratio of having the acetabular component outside the target zone. A greater proportion of THAs that were undertaken with the patient in the lateral decubitus position had Δinclination and/or Δanteversion > ± 10° (35.3%, 54/153) compared with those in the supine position (4.8%, 8/167; p < 0.001). A greater number of acetabular components were within the target zone in THAs undertaken with the patient in the supine position (72%, 120/167), compared with those in the lateral decubitus position (44%, 67/153; p < 0.001). Intraoperatively, the pelvis was more anteriorly tilted (p < 0.001) and more internally rotated (p = 0.04) when the patient was in the lateral decubitus position. Conclusion The pelvic position is more reliable when the patient is in the supine position, leading to more consistent orientation of the acetabular component. Significant differences in pelvic tilt and rotation are seen with the patient in the lateral decubitus position. Cite this article: Bone Joint J 2018;100-B:1280–8.
Collapse
Affiliation(s)
| | | | | | | | - A. Carli
- The Ottawa Hospital, Ottawa, Canada
| | | | | | | |
Collapse
|
19
|
Teeter MG, Lanting BA, Naudie DD, McCalden RW, Howard JL, MacDonald SJ. Highly crosslinked polyethylene wear rates and acetabular component orientation: a minimum ten-year follow-up. Bone Joint J 2018; 100-B:891-897. [PMID: 29954202 DOI: 10.1302/0301-620x.100b7.bjj-2017-1457.r3] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Aims The aim of this study was to determine whether there is a difference in the rate of wear between acetabular components positioned within and outside the 'safe zones' of anteversion and inclination angle. Patients and Methods We reviewed 100 hips in 94 patients who had undergone primary total hip arthroplasty (THA) at least ten years previously. Patients all had the same type of acetabular component with a bearing couple which consisted of a 28 mm cobalt-chromium head on a highly crosslinked polyethylene (HXLPE) liner. A supine radiostereometric analysis (RSA) examination was carried out which acquired anteroposterior (AP) and lateral paired images. Acetabular component anteversion and inclination angles were measured as well as total femoral head penetration, which was divided by the length of implantation to determine the rate of polyethylene wear. Results The mean anteversion angle was 19.4° (-15.2° to 48°, sd 11.4°), the mean inclination angle 43.4° (27.3° to 60.5°, sd 6.6°), and the mean wear rate 0.055 mm/year (sd 0.060). Exactly half of the hips were positioned inside the 'safe zone'. There was no difference (median difference, 0.012 mm/year; p = 0.091) in the rate of wear between acetabular components located within or outside the 'safe zone'. When compared to acetabular components located inside the 'safe zone', the wear rate was no different for acetabular components that only achieved the target anteversion angle (median difference, 0.012 mm/year; p = 0.138), target inclination angle (median difference, 0.013 mm/year; p = 0.354), or neither target (median difference, 0.012 mm/year; p = 0.322). Conclusion Placing the acetabular component within or outside the 'safe zone' did not alter the wear rate of HXLPE at long-term follow-up to a level that risked osteolysis. HXLPE appears to be a forgiving bearing material in terms of articular surface wear, but care must still be taken to position the acetabular component correctly so that the implant is stable. Cite this article: Bone Joint J 2018;100-B:891-7.
Collapse
Affiliation(s)
- M G Teeter
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - B A Lanting
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - D D Naudie
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - R W McCalden
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - J L Howard
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - S J MacDonald
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| |
Collapse
|
20
|
Effect of Pelvic Tilt and Rotation on Cup Orientation in Both Supine and Standing Positions. J Arthroplasty 2018; 33:1442-1448. [PMID: 29276116 DOI: 10.1016/j.arth.2017.11.069] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2017] [Revised: 11/15/2017] [Accepted: 11/30/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The purpose of this study is to analyze the effect of pelvic tilt and rotation on radiographic measurement of cup orientation. METHODS A total of 68 patients (79 hips) were included in this study. The patients had a computed tomography study and approximately 3 months of postoperative standing anteroposterior pelvic radiographs in both supine and standing positions. We used 2-dimensional (2D)/3-dimensional (3D) matching to measure pelvic tilt and rotation, and cup orientation. RESULTS There was a wide range of pelvic tilt between individuals in both supine and standing positions. Supine pelvic tilt was different from standing pelvic tilt (P < .05). There were differences in cup anteversion before and after 2D/3D matching in both supine and standing positions (P < .05). Supine and standing pelvic tilt correlated with differences in cup anteversion before and after 2D/3D matching. When all 79 hips were separated into right and left side, pelvic rotation inversely correlated with the pelvic tilt-adjusted difference in anteversion before and after 2D/3D matching of the right side but directly correlated with that of the left side in both supine and standing positions. CONCLUSION This study demonstrated that the measurement of cup anteversion on anteroposterior radiographs is significantly affected by both pelvic tilt and pelvic rotation (depending on the side). Improved understanding of pelvic orientation and improved ability to measure pelvic orientation may eventually allow for desired cup positioning to potentially protect against complications associated with malposition of the cup.
Collapse
|
21
|
Teeter MG, Goyal P, Yuan X, Howard JL, Lanting BA. Change in Acetabular Cup Orientation From Supine to Standing Position and Its Effect on Wear of Highly Crosslinked Polyethylene. J Arthroplasty 2018; 33:263-267. [PMID: 28917617 DOI: 10.1016/j.arth.2017.08.016] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2017] [Revised: 07/19/2017] [Accepted: 08/12/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The purpose of this study is to measure acetabular cup position and wear of the highly crosslinked polyethylene liner in the supine and standing position for patients at a minimum of 10 years after the operation. METHODS A total of 38 patients were recruited at a mean of 12.5 years after the operation. All patients received a single acetabular cup design with a highly crosslinked liner and a 28-mm cobalt-chromium femoral head. Patients underwent supine and standing radiostereometric examinations in which the X-ray sources and detectors were positioned to obtain an anterior-posterior and cross-table lateral radiograph. Acetabular cup position and the three-dimensional wear rate were measured from the radiographs, and outcome scores were recorded for each patient. RESULTS Anteversion significantly increased (P < .0001) a mean of 12° from supine (15.1° ± 10.4°) to standing (27.2° ± 10.5°) position. Inclination also significantly increased (P = .001) a mean of 2° from supine (44.4° ± 6.8°) to standing (46.3° ± 7.7°) position. There was no difference (P = .093) in wear rate between supine (0.067 ± 0.070 mm/y) and standing (0.073 ± 0.074 mm/y) positions. There were no correlations between cup orientation and wear rate in either position. CONCLUSION Highly crosslinked polyethylene is a forgiving bearing material. Although adherence to the traditional acetabular position target zone is recommended, ensuring hip stability and consideration of the patient's functional position are also important objectives to consider for the acetabular position.
Collapse
Affiliation(s)
- Matthew G Teeter
- Department of Surgery, Schulich School of Medicine & Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada; Surgical Innovation Program, Lawson Health Research Institute, London, Ontario, Canada; Imaging Research Laboratories, Robarts Research Institute, London, Ontario, Canada
| | - Prateek Goyal
- Department of Surgery, Schulich School of Medicine & Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - Xunhua Yuan
- Imaging Research Laboratories, Robarts Research Institute, London, Ontario, Canada
| | - James L Howard
- Department of Surgery, Schulich School of Medicine & Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - Brent A Lanting
- Department of Surgery, Schulich School of Medicine & Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| |
Collapse
|
22
|
McCarthy TF, Nevelos J, Elmallah RK, Chughtai M, Khlopas A, Alipit V, Wagner TC, Mont MA. The Effect of Pelvic Tilt and Femoral Head Size on Hip Range-of-Motion to Impingement. J Arthroplasty 2017; 32:3544-3549. [PMID: 28712801 DOI: 10.1016/j.arth.2017.06.016] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2017] [Revised: 05/18/2017] [Accepted: 06/06/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND About 50%-70% of dislocators have cups placed within so-called "safe zones." It has been postulated that factors such as femoral head size and pelvic tilt, obliquity, or rotation may influence postoperative stability. Therefore, we assessed varying degrees of pelvic tilt and head sizes on the range of motion (ROM) to impingement. METHODS A hip simulator was used to import models of 10 subjects who performed object pickup, squatting, and low-chair rising. Parameters were set for pelvic tilt, stem version, and the specific motions as defined by the subjects. Femur-to-pelvis relative motions were determined for abduction/adduction, internal/external rotation, and flexion/extension. Varying tilt angles were tested. Thirty-two millimeter and 36-mm head with a standard cup and 42-mm dual mobility cup were tested. Cup orientations for abduction and anteversion combinations were chosen, and computations of minimum clearances or impingement between components were made. RESULTS The ROM to impingement varied with the different pelvic tilts and femoral head sizes and with the different motions. The larger the head size, the larger the impingement-free ROM. Negative 10° of pelvic tilt led to the largest impingement-free zone, whereas 10° of forward tilt was associated with fewer impingement-free cup anteversion and abduction angle combinations. Variations in pelvic tilt had the greatest influence on object pickup and affected the impingement-free "safe zone." CONCLUSION Targets for impingement-free motion may be smaller when considering varying pelvic tilts and femoral head sizes, particularly for certain activities, such as object pickup. These findings may indicate the need for more individualized patient planning.
Collapse
Affiliation(s)
| | | | - Randa K Elmallah
- Department of Orthopaedic Surgery, University of Mississippi, Jackson, Mississippi
| | - Morad Chughtai
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, Ohio
| | - Anton Khlopas
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, Ohio
| | | | - Timothy C Wagner
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, Ohio
| | - Michael A Mont
- Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, Ohio
| |
Collapse
|
23
|
Uemura K, Takao M, Hamada H, Sakai T, Sugano N. Change in Axial Rotation of the Femur in the Resting Supine Position Following Total Hip Arthroplasty. Artif Organs 2017; 42:290-296. [DOI: 10.1111/aor.12998] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2017] [Revised: 06/20/2017] [Accepted: 06/29/2017] [Indexed: 01/25/2023]
Affiliation(s)
- Keisuke Uemura
- Department of Orthopaedic Medical Engineering; Osaka University Graduate School of Medicine; Suita Osaka Japan
| | - Masaki Takao
- Department of Orthopaedic Medical Engineering; Osaka University Graduate School of Medicine; Suita Osaka Japan
| | - Hidetoshi Hamada
- Department of Orthopaedic Surgery; Osaka University Graduate School of Medicine; Suita Osaka Japan
| | - Takashi Sakai
- Department of Orthopaedic Surgery; Osaka University Graduate School of Medicine; Suita Osaka Japan
| | - Nobuhiko Sugano
- Department of Orthopaedic Medical Engineering; Osaka University Graduate School of Medicine; Suita Osaka Japan
| |
Collapse
|
24
|
Uemura K, Takao M, Otake Y, Koyama K, Yokota F, Hamada H, Sakai T, Sato Y, Sugano N. Change in Pelvic Sagittal Inclination From Supine to Standing Position Before Hip Arthroplasty. J Arthroplasty 2017; 32:2568-2573. [PMID: 28392134 DOI: 10.1016/j.arth.2017.03.015] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/08/2016] [Revised: 03/01/2017] [Accepted: 03/07/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Cup anteversion and inclination are important for avoiding implant impingement and dislocation in total hip arthroplasty. However, functional cup anteversion and cup inclination also change as the pelvic sagittal inclination (PSI) changes. Therefore, PSI in both supine and standing positions was measured in a large cohort in this study. METHODS A total of 422 patients (median age, 61; range, 15-87) who underwent total hip arthroplasty were the subjects of this study. There were 83 patients with primary osteoarthritis (OA), 274 patients with developmental dysplasia-derived secondary OA, 48 patients with osteonecrosis, and 17 patients with rapidly destructive coxopathy (RDC). Preoperative PSI in supine and standing positions was measured by automated computed topography segmentation and landmark localization of the pelvis followed by intensity-based 2D-3D registration, and the number of cases in which PSI changed more than 10° posteriorly was calculated. Hip disease, sex, and age were analyzed if they were related to a PSI change of more than 10°. RESULTS The median PSI was 5.1° (interquartile range, 0.4°-9.4°) in supine and -1.3° (interquartile range, -6.5° to 4.2°) in standing position. There were 79 cases (19%) in which the PSI changed more than 10° posteriorly from supine to standing. Elder age and patients with primary OA and RDC were revealed to be the related factors. CONCLUSION PSI changed more than 10° posteriorly from supine to standing in 19% of cases. Age and diagnosis of primary OA and RDC were the significant factors for the posterior rotation.
Collapse
Affiliation(s)
- Keisuke Uemura
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Suita City, Osaka, Japan
| | - Masaki Takao
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Suita City, Osaka, Japan
| | - Yoshito Otake
- Imaging-based Computational Biomedicine Lab, Nara Institute of Science and Technology, Ikoma City, Nara, Japan
| | - Koki Koyama
- Imaging-based Computational Biomedicine Lab, Nara Institute of Science and Technology, Ikoma City, Nara, Japan
| | - Futoshi Yokota
- Imaging-based Computational Biomedicine Lab, Nara Institute of Science and Technology, Ikoma City, Nara, Japan
| | - Hidetoshi Hamada
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Suita City, Osaka, Japan
| | - Takashi Sakai
- Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Suita City, Osaka, Japan
| | - Yoshinobu Sato
- Imaging-based Computational Biomedicine Lab, Nara Institute of Science and Technology, Ikoma City, Nara, Japan
| | - Nobuhiko Sugano
- Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, Suita City, Osaka, Japan
| |
Collapse
|
25
|
Goyal P, Lau A, McCalden R, Teeter MG, Howard JL, Lanting BA. Accuracy of the modified Hardinge approach in acetabular positioning. Can J Surg 2017; 59:247-53. [PMID: 27240130 DOI: 10.1503/cjs.011415] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND The surgical approach chosen for total hip arthroplasty (THA) may affect the positioning of the acetabular component. The purpose of this study was to examine the accuracy in orienting the acetabular component using the modified Hardinge approach. METHODS We used our institutional arthroplasty database to identify patients with primary, press-fit, hemispherical acetabular components of a metal-on-polyethylene THA performed between 2003 and 2011. Patients with radiographs obtained 1-3 years after the index procedure were included for measurement of anteversion and inclination angles. Acceptable values of anteversion and abduction angles were defined as 15° ± 10° and 40° ± 10°, respectively. RESULTS We identified 1241 patients from the database, and the modified Hardinge approach was used in 1010 of the patients included in our analysis. The acetabular component was anteverted in the acceptable zone in 54.1% of patients. The abduction angle was within the defined range in 79.2% of patients. Combined anteversion and abduction angles within the defined zone were present in 43.6% of patients. CONCLUSION Consistent with studies examining accuracy from other approaches, our study reveals that the modified Hardinge approach was only moderately accurate in positioning the acetabular component in the acceptable zone.
Collapse
Affiliation(s)
- Prateek Goyal
- From the Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON (Goyal, McCalden, Teeter, Lau, Howard, Lanting); the Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, London, ON (Teeter)l; and the Surgical Innovation Program, Lawson Health Research Institute, London, ON (Teeter)
| | - Adrian Lau
- From the Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON (Goyal, McCalden, Teeter, Lau, Howard, Lanting); the Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, London, ON (Teeter)l; and the Surgical Innovation Program, Lawson Health Research Institute, London, ON (Teeter)
| | - Richard McCalden
- From the Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON (Goyal, McCalden, Teeter, Lau, Howard, Lanting); the Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, London, ON (Teeter)l; and the Surgical Innovation Program, Lawson Health Research Institute, London, ON (Teeter)
| | - Matthew G Teeter
- From the Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON (Goyal, McCalden, Teeter, Lau, Howard, Lanting); the Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, London, ON (Teeter)l; and the Surgical Innovation Program, Lawson Health Research Institute, London, ON (Teeter)
| | - James L Howard
- From the Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON (Goyal, McCalden, Teeter, Lau, Howard, Lanting); the Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, London, ON (Teeter)l; and the Surgical Innovation Program, Lawson Health Research Institute, London, ON (Teeter)
| | - Brent A Lanting
- From the Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON (Goyal, McCalden, Teeter, Lau, Howard, Lanting); the Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, London, ON (Teeter)l; and the Surgical Innovation Program, Lawson Health Research Institute, London, ON (Teeter)
| |
Collapse
|
26
|
Chang JD, Kim IS, Bhardwaj AM, Badami RN. The Evolution of Computer-Assisted Total Hip Arthroplasty and Relevant Applications. Hip Pelvis 2017; 29:1-14. [PMID: 28316957 PMCID: PMC5352720 DOI: 10.5371/hp.2017.29.1.1] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2017] [Revised: 01/31/2017] [Accepted: 02/09/2017] [Indexed: 12/27/2022] Open
Abstract
In total hip arthroplasty (THA), the accurate positioning of implants is the key to achieve a good clinical outcome. Computer-assisted orthopaedic surgery (CAOS) has been developed for more accurate positioning of implants during the THA. There are passive, semi-active, and active systems in CAOS for THA. Navigation is a passive system that only provides information and guidance to the surgeon. There are 3 types of navigation: imageless navigation, computed tomography (CT)-based navigation, and fluoroscopy-based navigation. In imageless navigation system, a new method of registration without the need to register the anterior pelvic plane was introduced. CT-based navigation can be efficiently used for pelvic plane reference, the functional pelvic plane in supine which adjusts anterior pelvic plane sagittal tilt for targeting the cup orientation. Robot-assisted system can be either active or semi-active. The active robotic system performs the preparation for implant positioning as programmed preoperatively. It has been used for only femoral implant cavity preparation. Recently, program for cup positioning was additionally developed. Alternatively, for ease of surgeon acceptance, semi-active robot systems are developed. It was initially applied only for cup positioning. However, with the development of enhanced femoral workflows, this system can now be used to position both cup and stem. Though there have been substantial advancements in computer-assisted THA, its use can still be controversial at present due to the steep learning curve, intraoperative technical issues, high cost and etc. However, in the future, CAOS will certainly enable the surgeon to operate more accurately and lead to improved outcomes in THA as the technology continues to evolve rapidly.
Collapse
Affiliation(s)
- Jun-Dong Chang
- Arthroplasty Center, Department of Orthopedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Korea
| | - In-Sung Kim
- Arthroplasty Center, Department of Orthopedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Korea
| | - Atul M Bhardwaj
- Arthroplasty Center, Department of Orthopedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Korea
| | - Ramachandra N Badami
- Arthroplasty Center, Department of Orthopedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Korea
| |
Collapse
|
27
|
Goyal P, Lau A, Naudie DD, Teeter MG, Lanting BA, Howard JL. Effect of Acetabular Component Positioning on Functional Outcomes in Primary Total Hip Arthroplasty. J Arthroplasty 2017; 32:843-848. [PMID: 27965176 DOI: 10.1016/j.arth.2016.08.024] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2015] [Revised: 08/04/2016] [Accepted: 08/18/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Acetabular component positioning is crucial to a successful total hip arthroplasty (THA). This study evaluated the effect of absolute acetabular component position as well as acetabular position relative to bony anatomy on patient-reported functional outcomes after primary THA. METHODS Primary, press fit, hemispherical metal-on-polyethylene THA performed between 2003 and 2011 were analyzed. Western Ontario and McMaster Osteoarthritis Index (WOMAC), Harris Hip Score (HHS), Short Form-12 scores, and radiographs between 2 and 3 years after the index procedure were assessed. RESULTS Of the 1241 primary THA included, the mean abduction and anteversion angles were 44.4 ± 6.94 and 21.7 ± 11.9 degrees, respectively. The mean anterior and lateral overhang were 1.9 ± 3.6 and 2.5 ± 3.4 mm, respectively. There was no correlation between functional outcomes and acetabular inclination. A weak positive correlation between anteversion and HHS (P < .001) and WOMAC (P = .02) scores was found. For relative position, anterior overhang of the acetabular component beyond the bone resulted in inferior Short Form-12 physical function (P = .001), HHS (P = .004), and WOMAC (P < .001) scores compared to those with bony coverage. Mean HHS pain score was 41.20 ± 5.69 in patients with lateral overhang and 41.97 ± 5.04 in those who had bony coverage of the lateral edge of the acetabular component (P = .02). CONCLUSION The tribology and biomechanics of acetabular component position have been extensively studied without examination of how it affects patient function. Although statistical significance was seen, clinical outcome scores were not sensitive enough to show a clinically significant effect of the absolute or relative position of the acetabular component.
Collapse
Affiliation(s)
- Prateek Goyal
- Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON, Canada
| | - Adrian Lau
- Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON, Canada
| | - Douglas D Naudie
- Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON, Canada
| | - Matthew G Teeter
- Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON, Canada; Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, London, ON, Canada; Surgical Innovation Program, Lawson Health Research Institute, London, ON, Canada
| | - Brent A Lanting
- Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON, Canada
| | - James L Howard
- Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, ON, Canada
| |
Collapse
|
28
|
Seagrave KG, Troelsen A, Malchau H, Husted H, Gromov K. Acetabular cup position and risk of dislocation in primary total hip arthroplasty. Acta Orthop 2017; 88:10-17. [PMID: 27879150 PMCID: PMC5251254 DOI: 10.1080/17453674.2016.1251255] [Citation(s) in RCA: 149] [Impact Index Per Article: 21.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed a systematic review to describe the different methods for measuring cup placement, target zones for cup positioning, and the association between cup positioning and dislocation following primary THA. Methods - A systematic search of literature in the PubMed database was performed (January and February 2016) to identify articles that compared acetabular cup positioning and the risk of dislocation. Surgical approach and methods for measurement of cup angles were also considered. Results - 28 articles were determined to be relevant to our research question. Some articles demonstrated that cup positioning influenced postoperative dislocation whereas others did not. The majority of articles could not identify a statistically significant difference between dislocating and non-dislocating THA with regard to mean angles of cup anteversion and inclination. Most of the articles that assessed cup placement within the Lewinnek safe zone did not show a statistically significant reduction in dislocation rate. Alternative target ranges have been proposed by several authors. Interpretation - The Lewinnek safe zone could not be justified. It is difficult to draw broad conclusions regarding a definitive target zone for cup positioning in THA, due to variability between studies and the likely multifactorial nature of THA dislocation. Future studies comparing cup positioning and dislocation rate should investigate surgical approach separately. Standardized tools for measurement of cup positioning should be implemented to allow comparison between studies.
Collapse
Affiliation(s)
- Kurt G Seagrave
- Faculty of Medicine, University of New South Wales, Sydney, Australia,Department of Orthopaedic Surgery, Copenhagen University Hospital Hvidovre. Copenhagen, Denmark
| | - Anders Troelsen
- Department of Orthopaedic Surgery, Copenhagen University Hospital Hvidovre. Copenhagen, Denmark
| | - Henrik Malchau
- Harris Orthopaedic Laboratory, Massachusetts General Hospital,Department of Orthopaedic Surgery, Harvard Medical School, Boston, MA, USA
| | - Henrik Husted
- Department of Orthopaedic Surgery, Copenhagen University Hospital Hvidovre. Copenhagen, Denmark
| | - Kirill Gromov
- Department of Orthopaedic Surgery, Copenhagen University Hospital Hvidovre. Copenhagen, Denmark,Correspondence:
| |
Collapse
|
29
|
Analysis of acetabular orientation and femoral anteversion using images of three-dimensional reconstructed bone models. Int J Comput Assist Radiol Surg 2017; 12:855-864. [PMID: 28063078 DOI: 10.1007/s11548-016-1514-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2016] [Accepted: 12/15/2016] [Indexed: 10/20/2022]
Abstract
PURPOSE Radiographic measurements using two-dimensional (2D) plain radiographs or planes from computed tomography (CT) scans have several drawbacks, while measurements using images of three-dimensional (3D) reconstructed bone models can provide more consistent anthropometric information. We compared the consistency of results using measurements based on images of 3D reconstructed bone models (3D measurements) with those using planes from CT scans (measurements using 2D slice images). METHODS Ninety-six of 561 patients who had undergone deep vein thrombosis-CT between January 2013 and November 2014 were randomly selected. We evaluated measurements using 2D slice images and 3D measurements. The images used for 3D reconstruction of bone models were obtained and measured using [Formula: see text] and [Formula: see text] (Materialize, Leuven, Belgium). RESULTS The mean acetabular inclination, acetabular anteversion and femoral anteversion values on 2D slice images were 42.01[Formula: see text], 18.64[Formula: see text] and 14.44[Formula: see text], respectively, while those using images of 3D reconstructed bone models were 52.80[Formula: see text], 14.98[Formula: see text] and 17.26[Formula: see text]. Intra-rater reliabilities for acetabular inclination, acetabular anteversion, and femoral anteversion on 2D slice images were 0.55, 0.81, and 0.85, respectively, while those for 3D measurements were 0.98, 0.99, and 0.98. Inter-rater reliabilities for acetabular inclination, acetabular anteversion and femoral anteversion on 2D slice images were 0.48, 0.86, and 0.84, respectively, while those for 3D measurements were 0.97, 0.99, and 0.97. CONCLUSION The differences between the two measurements are explained by the use of different tools. However, more consistent measurements were possible using the images of 3D reconstructed bone models. Therefore, 3D measurement can be a good alternative to measurement using 2D slice images.
Collapse
|
30
|
Kamara E, Robinson J, Bas MA, Rodriguez JA, Hepinstall MS. Adoption of Robotic vs Fluoroscopic Guidance in Total Hip Arthroplasty: Is Acetabular Positioning Improved in the Learning Curve? J Arthroplasty 2017; 32:125-130. [PMID: 27499519 DOI: 10.1016/j.arth.2016.06.039] [Citation(s) in RCA: 81] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/11/2015] [Revised: 06/01/2016] [Accepted: 06/21/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Acetabulum positioning affects dislocation rates, component impingement, bearing surface wear rates, and need for revision surgery. Novel techniques purport to improve the accuracy and precision of acetabular component position, but may have a significant learning curve. Our aim was to assess whether adopting robotic or fluoroscopic techniques improve acetabulum positioning compared to manual total hip arthroplasty (THA) during the learning curve. METHODS Three types of THAs were compared in this retrospective cohort: (1) the first 100 fluoroscopically guided direct anterior THAs (fluoroscopic anterior [FA]) done by a surgeon learning the anterior approach, (2) the first 100 robotic-assisted posterior THAs done by a surgeon learning robotic-assisted surgery (robotic posterior [RP]), and (3) the last 100 manual posterior (MP) THAs done by each surgeon (200 THAs) before adoption of novel techniques. Component position was measured on plain radiographs. Radiographic measurements were taken by 2 blinded observers. The percentage of hips within the surgeons' "target zone" (inclination, 30°-50°; anteversion, 10°-30°) was calculated, along with the percentage within the "safe zone" of Lewinnek (inclination, 30°-50°; anteversion, 5°-25°) and Callanan (inclination, 30°-45°; anteversion, 5°-25°). Relative risk (RR) and absolute risk reduction (ARR) were calculated. Variances (square of the standard deviations) were used to describe the variability of cup position. RESULTS Seventy-six percentage of MP THAs were within the surgeons' target zone compared with 84% of FA THAs and 97% of RP THAs. This difference was statistically significant, associated with a RR reduction of 87% (RR, 0.13 [0.04-0.40]; P < .01; ARR, 21%; number needed to treat, 5) for RP compared to MP THAs. Compared to FA THAs, RP THAs were associated with a RR reduction of 81% (RR, 0.19 [0.06-0.62]; P < .01; ARR, 13%; number needed to treat, 8). Variances were lower for acetabulum inclination and anteversion in RP THAs (14.0 and 19.5) as compared to the MP (37.5 and 56.3) and FA (24.5 and 54.6) groups. These differences were statistically significant (P < .01). CONCLUSION Adoption of robotic techniques delivers significant and immediate improvement in the precision of acetabular component positioning during the learning curve. While fluoroscopy has been shown to be beneficial with experience, a learning curve exists before precision improves significantly.
Collapse
Affiliation(s)
- Eli Kamara
- Department of Orthopaedic Surgery, Lenox Hill Hospital, New York, New York
| | - Jonathon Robinson
- Department of Orthopaedic Surgery, Mt. Sinai Hospital, New York, New York
| | - Marcel A Bas
- Department of Orthopaedic Surgery, Lenox Hill Hospital, New York, New York
| | - Jose A Rodriguez
- Department of Orthopaedic Surgery, Lenox Hill Hospital, New York, New York
| | | |
Collapse
|
31
|
Zahn RK, Grotjohann S, Pumberger M, Ramm H, Zachow S, Putzier M, Perka C, Tohtz S. Influence of pelvic tilt on functional acetabular orientation. Technol Health Care 2016; 25:557-565. [PMID: 27911346 DOI: 10.3233/thc-161281] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Pelvic tilt influences acetabular orientation (AO). Anatomical AO can be measured in relation to the anterior pelvic plane (APP), functional AO can be calculated relative to table's plane. OBJECTIVE To assess to what extent functional AO is determined by pelvic tilt and if APP and table plane give equal information for correct AO. METHODS AO was evaluated by computed tomography (CT) scans of 138 patients. Pelvic tilt, anatomical and functional AO were measured, differences between the two reference planes were calculated. RESULTS Anatomical and functional acetabular anteversion (AA) were found to be different in 21% of individuals with an enhanced extent of pelvic tilt. Functional AA was increased compared to anatomical AA at high posterior pelvic tilt (p < 0.001). Enlarged anterior tilting of the pelvis reduced APP-related AA (p < 0.002). Anatomical AA positively correlated with pelvic tilt, particularly in females (p < 0.01, correlation coefficient = 0.698, R2 = 0.523). CONCLUSIONS APP and table plane do not provide equal information about AO at enhanced pelvic tilt. Functional orientation of the acetabulum is dependent on pelvic tilt, which itself is influenced by anatomical AA and should therefore be analyzed for precise AO.
Collapse
Affiliation(s)
- Robert K Zahn
- Department for Orthopaedics, Department for Traumatology, Center for Musculoskeletal Surgery, Charité-University Medicine Berlin, 10117 Berlin, Germany
| | - Sarah Grotjohann
- Department for Orthopaedics, Department for Traumatology, Center for Musculoskeletal Surgery, Charité-University Medicine Berlin, 10117 Berlin, Germany
| | - Matthias Pumberger
- Department for Orthopaedics, Department for Traumatology, Center for Musculoskeletal Surgery, Charité-University Medicine Berlin, 10117 Berlin, Germany
| | - Heiko Ramm
- Visualization & Data Analysis Medical Planning & Computational Medicine Groups, Zuse Institute Berlin, 14195 Berlin, Germany
| | - Stefan Zachow
- Visualization & Data Analysis Medical Planning & Computational Medicine Groups, Zuse Institute Berlin, 14195 Berlin, Germany
| | - Michael Putzier
- Department for Orthopaedics, Department for Traumatology, Center for Musculoskeletal Surgery, Charité-University Medicine Berlin, 10117 Berlin, Germany
| | - Carsten Perka
- Department for Orthopaedics, Department for Traumatology, Center for Musculoskeletal Surgery, Charité-University Medicine Berlin, 10117 Berlin, Germany
| | - Stephan Tohtz
- HELIOS Klinikum Emil von Behring, Oskar-Helene-Heim, Department for Orthopaedics and Traumatology, 14165 Berlin, Germany
| |
Collapse
|
32
|
Acetabular Cup Anteversion and Inclination in Hip Range of Motion to Impingement. J Arthroplasty 2016; 31:264-8. [PMID: 27067753 DOI: 10.1016/j.arth.2016.01.067] [Citation(s) in RCA: 44] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2015] [Revised: 01/20/2016] [Accepted: 01/26/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND It is advocated that to avoid complications associated with femoral stem impingement, acetabular positioning should be within a "safe zone." However, instability remains prevalent despite accurate cup positioning, with studies showing dislocations of cups despite positioning within safe zones. We assessed cup position angles associated with impingement in a group of subjects during (1) squatting; (2) object pick-up; and (3) low chair rise. METHODS Ten subjects (mean age, 69 years; body mass index, 28.4 kg/m(2)) performed object pick up, squatting, and low-chair rising. Femur-to-pelvis relative motions were recorded for flexion/extension, abduction/adduction, and internal/external rotation. A previously reported custom-validated hip range-of-motion 3-dimensional simulator was used, set for neutral pelvic tilt and 15(°) of stem version. Acetabular cup abduction and anteversion combinations were chosen. The software computed minimum clearances between components for any hip position. An idealized tapered wedge stem with a 132° neck angle and a 36-mm femoral head was used. RESULTS Eight subjects had impingement on squatting between 21(°) and 51(°) of inclination. During object pick-up, 9 subjects had impingement with inclination and anteversion angles within the "safe zone." In low-chair rise, 8 subjects had impingement at cup inclination angles between 14.5(°) and 49.5(°). CONCLUSION The true acetabular target for impingement-avoidance motion is much smaller than previously believed and varies considerably between patients. Certain activities, such as picking up an object, low-chair rise, and squatting reduce the size of the safe zone. This study supports the need for better individualized preoperative patient-specific planning and intraoperative execution for placement of the components.
Collapse
|
33
|
|
34
|
|
35
|
Pelvic tilt compensates for increased acetabular anteversion. INTERNATIONAL ORTHOPAEDICS 2015; 40:1571-1575. [PMID: 26318879 DOI: 10.1007/s00264-015-2949-6] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/21/2015] [Accepted: 07/24/2015] [Indexed: 10/23/2022]
Abstract
PURPOSE Pelvic tilt determines functional orientation of the acetabulum. In this study, we investigated the interaction of pelvic tilt and functional acetabular anteversion (AA) in supine position. METHODS Pelvic tilt and AA of 138 individuals were measured by computed tomography (CT). AA was calculated in relation to the anterior pelvic plane (APP) and relative to the table plane. We analysed these parameters for gender-specific and age-related differences. RESULTS The mean pelvic tilt was -0.1 ± 5.5°. Pelvic sagittal rotation displayed no gender nor age related differences. Females showed higher angles of AA compared with males (20.0° vs 17.2°, p < 0.001; AA relative to the APP). Anterior tilting of the pelvis positively correlated with AA and individuals with high AA had a higher anterior pelvic tilt compared with those with low AA (p < 0.0001; AA relative to the APP). CONCLUSIONS AA has to be calculated regarding pelvic sagittal rotation for correct acetabular orientation. Pelvic tilt is dependent on acetabular orientation and compensates for increased AA.
Collapse
|
36
|
Baauw M, van Hellemondt GG, van Hooff ML, Spruit M. The accuracy of positioning of a custom-made implant within a large acetabular defect at revision arthroplasty of the hip. Bone Joint J 2015; 97-B:780-5. [DOI: 10.1302/0301-620x.97b6.35129] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
We evaluated the accuracy with which a custom-made acetabular component could be positioned at revision arthroplasty of the hip in patients with a Paprosky type 3 acetabular defect. A total of 16 patients with a Paprosky type 3 defect underwent revision surgery using a custom-made trabecular titanium implant. There were four men and 12 women with a median age of 67 years (48 to 79). The planned inclination (INCL), anteversion (AV), rotation and centre of rotation (COR) of the implant were compared with the post-operative position using CT scans. A total of seven implants were malpositioned in one or more parameters: one with respect to INCL, three with respect to AV, four with respect to rotation and five with respect to the COR. To the best of our knowledge, this is the first study in which CT data acquired for the pre-operative planning of a custom-made revision acetabular implant have been compared with CT data on the post-operative position. The results are encouraging. Cite this article: Bone Joint J 2015; 97-B:780–5.
Collapse
Affiliation(s)
- M. Baauw
- Sint Maartenskliniek, P.
O. Box 9011, 6500 GM Nijmegen, The
Netherlands
| | | | - M. L. van Hooff
- Sint Maartenskliniek, P.
O. Box 9011, 6500 GM Nijmegen, The
Netherlands
| | - M. Spruit
- Sint Maartenskliniek, P.
O. Box 9011, 6500 GM Nijmegen, The
Netherlands
| |
Collapse
|
37
|
Bouma HW, Hogervorst T, Audenaert E, Krekel P, van Kampen PM. Can combining femoral and acetabular morphology parameters improve the characterization of femoroacetabular impingement? Clin Orthop Relat Res 2015; 473:1396-403. [PMID: 25384428 PMCID: PMC4353537 DOI: 10.1007/s11999-014-4037-4] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Femoroacetabular impingement (FAI) presupposes a dynamic interaction of the proximal femur and acetabulum producing clinical symptoms and chondrolabral damage. Currently, FAI classification is based on alpha angle and center-edge angle measurements in a single plane. However, acetabular and femoral version and neck-shaft angle also influence FAI. Furthermore, each of these parameters has a reciprocal interaction with the others; for example, a shallow acetabulum delays impingement of the femoral head with the acetabular rim. QUESTIONS/PURPOSES We introduce the new parameter "omega zone," which combines five parameters into one: the alpha and center-edge angles, acetabular and femoral version, and neck-shaft angle. We sought to determine whether the omega zone could differentiate patients with FAI from (1) normal control subjects (alpha < 55°), but also from (2) control subjects with elevated alpha angles (≥ 55°). METHODS We evaluated CT data of 20 hips of male patients with symptomatic cam-type FAI and of 35 male hips extracted from 110 anonymized CT scans for vascular diagnosis. We excluded hips with osteoarthritis, developmental dysplasia, or coxa profunda (center-edge angle 20°-45° on AP pelvic view or corresponding coronal CT views). With dedicated software, femoral and pelvic orientation was standardized; we tested the omega zone in four hip positions in three distinct groups: patients with cam-type FAI (alpha > 60°) and control subjects with normal (< 55°) and high alpha angles (≥ 55°). RESULTS The omega zone was smaller in patients with cam-type FAI than normal control subjects (alpha angle < 55°) at 60° and 90° of flexion (mean, 12%; 95% confidence interval [CI], 7-17; p = 0.008; Cohen's d = 9%; 95% CI, 4-13; p = 0.003). Furthermore, the omega zone was smaller in all positions in patients with cam-type FAI than control subjects with high alpha angles (0° p = 0.017, 30° p = 0.004, 60° p = 0.004, 90° p = 0.007). In contrast, the omega zone did not differ between control subjects with normal or high alpha angles. In all hips, the omega zone decreased with flexion, corresponding to a decrease in remaining impingement-free motion with flexion. CONCLUSIONS The omega zone visualizes and quantifies the interaction of the proximal femur and acetabulum. The omega zone differed between patients with cam-type FAI and control subjects with high alpha angles (≥ 55°), who could not be distinguished based on alpha angle alone. For hip-preserving surgery, it can help surgeons decide whether to address the femur, the acetabulum, or both.
Collapse
Affiliation(s)
- Heinse W Bouma
- Department of Orthopaedic Surgery, Haga Hospital, Sportlaan 600, 2566 MJ, The Hague, The Netherlands,
| | | | | | | | | |
Collapse
|
38
|
Esposito CI, Gladnick BP, Lee YY, Lyman S, Wright TM, Mayman DJ, Padgett DE. Cup position alone does not predict risk of dislocation after hip arthroplasty. J Arthroplasty 2015; 30:109-13. [PMID: 25249516 PMCID: PMC4270833 DOI: 10.1016/j.arth.2014.07.009] [Citation(s) in RCA: 154] [Impact Index Per Article: 17.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2014] [Revised: 07/03/2014] [Accepted: 07/07/2014] [Indexed: 02/01/2023] Open
Abstract
We used a large prospective institutional registry to determine if there is a 'safe zone' that exists for acetabular component position within which the risk of hip dislocation is low and if other patient and implant factors affect the risk of hip dislocation. Patients who reported a dislocation event within six months after hip arthroplasty surgery were identified, and acetabular component position was measured with anteroposterior radiographs. The frequency of dislocation was 2.1% (147 of 7040 patients). No significant difference was found in the number of dislocated hips among the radiographic zones (±5°,±10°,±15° boundaries). Dislocators <50 years old were less active preoperatively than nondislocators (P=0.006). Acetabular component position alone is not protective against instability.
Collapse
Affiliation(s)
| | | | - Yuo-Yu Lee
- Hospital for Special Surgery, New York, New York
| | | | | | | | | |
Collapse
|
39
|
The kinematic relationship between sitting and standing posture and pelvic inclination and its significance to cup positioning in total hip arthroplasty. INTERNATIONAL ORTHOPAEDICS 2014; 39:383-8. [DOI: 10.1007/s00264-014-2491-y] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2014] [Accepted: 07/29/2014] [Indexed: 10/24/2022]
|
40
|
Nomura T, Naito M, Nakamura Y, Ida T, Kuroda D, Kobayashi T, Sakamoto T, Seo H. An analysis of the best method for evaluating anteversion of the acetabular component after total hip replacement on plain radiographs. Bone Joint J 2014; 96-B:597-603. [DOI: 10.1302/0301-620x.96b.33013] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Several radiological methods of measuring anteversion of the acetabular component after total hip replacement (THR) have been described. These studies used different definitions and reference planes to compare methods, allowing for misinterpretation of the results. We compared the reliability and accuracy of five current methods using plain radiographs (those of Lewinnek, Widmer, Liaw, Pradhan, and Woo and Morrey) with CT measurements, using the same definition and reference plane. We retrospectively studied the plain radiographs and CT scans in 84 hips of 84 patients who underwent primary THR. Intra- and inter-observer reliability were high for the measurement of inclination and anteversion with all methods on plain radiographs and CT scans. The measurements of inclination on plain radiographs were similar to the measurements using CT (p = 0.043). The mean difference between CT measurements was 0.6° (-5.9° to 6.8°). Measurements using Widmer’s method were the most similar to those using CT (p = 0.088), with a mean difference between CT measurements of -0.9° (-10.4° to 9.1°), whereas the other four methods differed significantly from those using CT (p < 0.001). This study has shown that Widmer’s method is the best for evaluating the anteversion of the acetabular component on plain radiographs. Cite this article: Bone Joint J 2014; 96-B:597–603.
Collapse
Affiliation(s)
- T. Nomura
- Department of Orthopaedic Surgery, Faculty
of Medicine, Fukuoka University, 7-45-1 Nanakuma, Jonan-ku, Fukuoka, 814-0180, Japan
| | - M. Naito
- Department of Orthopaedic Surgery, Faculty
of Medicine, Fukuoka University, 7-45-1 Nanakuma, Jonan-ku, Fukuoka, 814-0180, Japan
| | - Y. Nakamura
- Department of Orthopaedic Surgery, Faculty
of Medicine, Fukuoka University, 7-45-1 Nanakuma, Jonan-ku, Fukuoka, 814-0180, Japan
| | - T. Ida
- Department of Orthopaedic Surgery, Faculty
of Medicine, Fukuoka University, 7-45-1 Nanakuma, Jonan-ku, Fukuoka, 814-0180, Japan
| | - D. Kuroda
- Department of Orthopaedic Surgery, Faculty
of Medicine, Fukuoka University, 7-45-1 Nanakuma, Jonan-ku, Fukuoka, 814-0180, Japan
| | - T. Kobayashi
- Department of Orthopaedic Surgery, Faculty
of Medicine, Fukuoka University, 7-45-1 Nanakuma, Jonan-ku, Fukuoka, 814-0180, Japan
| | - T. Sakamoto
- Department of Orthopaedic Surgery, Faculty
of Medicine, Fukuoka University, 7-45-1 Nanakuma, Jonan-ku, Fukuoka, 814-0180, Japan
| | - H. Seo
- Department of Orthopaedic Surgery, Faculty
of Medicine, Fukuoka University, 7-45-1 Nanakuma, Jonan-ku, Fukuoka, 814-0180, Japan
| |
Collapse
|