1
|
Solou K, Panagopoulos A, Tatani I, Megas P. Fracture of femoral neck in modular total hip arthroplasty: a systematic review of the literature. Hip Int 2024; 34:409-420. [PMID: 37932248 DOI: 10.1177/11207000231211253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2023]
Abstract
BACKGROUND Modular femoral stems have the advantage of anatomic hip reconstruction by restoring the femoral offset thus minimising the bearing surface wear, implant loosening and dislocation. AIM This study aims to investigate the existing literature on modular neck fractures, to identify predisposing factors and guide the decision-making process in the management of these difficult cases. METHODS A systematic literature review was conducted until July 2022. PRISMA guidelines were followed, eligibility criteria were set, and methodology assessment of included studies was conducted based on MINORS criteria, size and primary outcome. Data were extracted and analysed thoroughly. RESULTS 5657 studies were initially screened; the full texts of 124 records were assessed and finally, 32 reports were included. There were 7 clinical studies and 25 case reports. A total of 4825 patients (5204 hips) with a mean age 62.38 years and a mean BMI 29.06 kg/m2 were analysed in the 7 clinical studies. The reported overall weighted revision rate was 0.86%, while the weighted mean modular neck fracture rate was 0.26%. The usual history was sudden experience of hip pain and instability. The average time interval to neck fracture was 4.57 (range 3-4.7) years and a long modular neck was identified in 91.17% of them. Data from case reports showed a mean age and average BMI of 55.85 and 31.63 kg/m2. 82.35% of the patients were male. Necks were fractured after an average time interval of 64.5 ± 8.8 months. CONCLUSIONS The incidence of modular neck fracture is significant. The profile of a male, obese patient with a long modular neck increased risk of neck fracture. Microstructural investigation of the retrieved implants demonstrated a higher incidence of fracture line in the base of the neck junction and at its anterolateral distal part. Surgeons should be aware of this complication while using or revising such protheses.
Collapse
Affiliation(s)
| | - Andreas Panagopoulos
- Faculty of Medicine, Patras University, Patra, Greece
- Orthopaedic Department, Patras General University Hospital, Patras, Greece
| | - Irini Tatani
- Faculty of Medicine, Patras University, Patra, Greece
- Orthopaedic Department, Patras General University Hospital, Patras, Greece
| | - Panagiotis Megas
- Faculty of Medicine, Patras University, Patra, Greece
- Orthopaedic Department, Patras General University Hospital, Patras, Greece
| |
Collapse
|
2
|
Scott DF, Eppich K, Mehić E, Gray C, Smith CL, Johnston M. 15-year survivorship of a unique dual-modular femoral stem in primary hip arthroplasty. BMC Musculoskelet Disord 2024; 25:312. [PMID: 38649874 PMCID: PMC11036691 DOI: 10.1186/s12891-024-07422-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Accepted: 04/06/2024] [Indexed: 04/25/2024] Open
Abstract
BACKGROUND Hip offset, version, and length are interdependent femoral variables which determine stability and leg length. Balancing these competing variables remains a core challenge in hip arthroplasty. The potential benefits of modular femoral stems have been overshadowed by higher rates of failure. The objective of this study was to assess the survivorship of a unique dual-modular femoral stem at an average 15-year follow-up period. METHODS The records of all patients with osteoarthritis who underwent primary total hip arthroplasty with this device between 2004-2009 were reviewed. There were no exclusions for BMI or other factors. We examined the data with Kaplan-Meier survival analysis. The primary endpoint for survival was mechanical failure of the modular neck-body junction. RESULTS The survivorship of this device in 172 subjects was 100% with none experiencing mechanical failure of the modular junction at an average of 15 years. 60 patients died of causes unrelated to their THA and 9 patients were lost to follow-up. There were three early (≤ 12 months) dislocations (1.7%), and seven total dislocations (4.1%). 16 patients underwent reoperations during the follow-up period, none for any complication of the modular junction. Radiographic results showed well-fixed femoral stems in all cases. There were no leg length discrepancies of greater than 10 mm, and 85% were within 5 mm. CONCLUSION There were no mechanical failures of the modular junction in any of the subjects over the average 15-year period, demonstrating that this dual-modular design is not associated with increased failure rates. We achieved a 1.7% early dislocation rate and a 4.1% total dislocation rate without any clinically significant leg length discrepancies.
Collapse
Affiliation(s)
- David F Scott
- Elson S. Floyd College of Medicine at Washington State University, 412 E Spokane Falls, Blvd, Spokane, WA, 99202, USA
- Spokane Joint Replacement Center, Inc., Spokane, WA, USA
| | - Kade Eppich
- Elson S. Floyd College of Medicine at Washington State University, 412 E Spokane Falls, Blvd, Spokane, WA, 99202, USA
| | - Edin Mehić
- University of Washington, School of Medicine, Seattle, WA, USA
| | - Celeste Gray
- Spokane Joint Replacement Center, Inc., Spokane, WA, USA
| | - Crystal Lederhos Smith
- Elson S. Floyd College of Medicine at Washington State University, 412 E Spokane Falls, Blvd, Spokane, WA, 99202, USA
| | - Michael Johnston
- Elson S. Floyd College of Medicine at Washington State University, 412 E Spokane Falls, Blvd, Spokane, WA, 99202, USA.
| |
Collapse
|
3
|
Bologna FA, Putame G, Audenino AL, Terzini M. Understanding the role of head size and neck length in micromotion generation at the taper junction in total hip arthroplasty. Sci Rep 2024; 14:6397. [PMID: 38493233 PMCID: PMC10944531 DOI: 10.1038/s41598-024-57017-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Accepted: 03/13/2024] [Indexed: 03/18/2024] Open
Abstract
Modular hip implants allow intra-operative adjustments for patient-specific customization and targeted replacement of damaged elements without full implant extraction. However, challenges arise from relative micromotions between components, potentially leading to implant failure due to cytotoxic metal debris. In this study magnitude and directions of micromotions at the taper junction were estimated, aiming to understand the effect of variations in head size and neck length. Starting from a reference configuration adhering to the 12/14 taper standard, six additional implant configurations were generated by varying the head size and/or neck length. A musculoskeletal multibody model of a prothesized lower limb was developed to estimate hip contact force and location during a normal walking task. Following the implant assembly, the multibody-derived loads were imposed as boundary conditions in a finite element analysis to compute the taper junction micromotions as the relative slip between the contacting surfaces. Results highlighted the L-size head as the most critical configuration, indicating a 2.81 μm relative slip at the mid-stance phase. The proposed approach enables the investigation of geometric variations in implants under accurate load conditions, providing valuable insights for designing less risky prostheses and informing clinical decision-making processes.
Collapse
Affiliation(s)
- Federico A Bologna
- PolitoBIOMed Lab, Politecnico di Torino, 10129, Turin, Italy
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, 10129, Turin, Italy
| | - Giovanni Putame
- PolitoBIOMed Lab, Politecnico di Torino, 10129, Turin, Italy
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, 10129, Turin, Italy
| | - Alberto L Audenino
- PolitoBIOMed Lab, Politecnico di Torino, 10129, Turin, Italy
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, 10129, Turin, Italy
| | - Mara Terzini
- PolitoBIOMed Lab, Politecnico di Torino, 10129, Turin, Italy.
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, 10129, Turin, Italy.
| |
Collapse
|
4
|
Gazo Hanna E, Younes K, Roufayel R, Khazaal M, Fajloun Z. Engineering innovations in medicine and biology: Revolutionizing patient care through mechanical solutions. Heliyon 2024; 10:e26154. [PMID: 38390063 PMCID: PMC10882044 DOI: 10.1016/j.heliyon.2024.e26154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 01/24/2024] [Accepted: 02/08/2024] [Indexed: 02/24/2024] Open
Abstract
The overlap between mechanical engineering and medicine is expanding more and more over the years. Engineers are now using their expertise to design and create functional biomaterials and are continually collaborating with physicians to improve patient health. In this review, we explore the state of scientific knowledge in the areas of biomaterials, biomechanics, nanomechanics, and computational fluid dynamics (CFD) in relation to the pharmaceutical and medical industry. Focusing on current research and breakthroughs, we provide an overview of how these fields are being used to create new technologies for medical treatments of human patients. Barriers and constraints in these fields, as well as ways to overcome them, are also described in this review. Finally, the potential for future advances in biomaterials to fundamentally change the current approach to medicine and biology is also discussed.
Collapse
Affiliation(s)
- Eddie Gazo Hanna
- College of Engineering and Technology, American University of the Middle East, Egaila, 54200, Kuwait
| | - Khaled Younes
- College of Engineering and Technology, American University of the Middle East, Egaila, 54200, Kuwait
| | - Rabih Roufayel
- College of Engineering and Technology, American University of the Middle East, Egaila, 54200, Kuwait
| | - Mickael Khazaal
- École Supérieure des Techniques Aéronautiques et de Construction Automobile, ISAE-ESTACA, France
| | - Ziad Fajloun
- Faculty of Sciences 3, Department of Biology, Lebanese University, Campus Michel Slayman Ras Maska, 1352, Tripoli, Lebanon
- Laboratory of Applied Biotechnology (LBA3B), Azm Center for Research in Biotechnology and Its Applications, EDST, Lebanese University, 1300, Tripoli, Lebanon
| |
Collapse
|
5
|
López RE, Pelayo de Tomás JM, Morales Suárez Varela M, Rodrigo Pérez JL. Evolution of chromium and cobalt serum levels after the use of a modular neck stem in primary total hip arthroplasty. Rev Esp Cir Ortop Traumatol (Engl Ed) 2024; 68:26-34. [PMID: 37270057 DOI: 10.1016/j.recot.2023.05.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 03/23/2023] [Accepted: 05/29/2023] [Indexed: 06/05/2023] Open
Abstract
INTRODUCTION AND OBJECTIVES Modular neck primary stems were introduced with the theoretical advantage of restoring the hip anatomy more precisely. However, the presence of a second junction has been associated with increased corrosion and release of metal debris. The objective of our study is to quantify of chromium and cobalt serum values, and to analyze their temporal evolution during five years. MATERIAL AND METHODS We present a prospective series of 61 patients who underwent primary total hip arthroplasty by implantation of the HMAX-M® stem (Limacorporate, San Daniele, Italy). Serum chromium and cobalt determinations were performed at six months, two years and five years. RESULTS Our series shows a progressive elevation in chromium levels with a significant difference between chromium values at six months (0.35±0.18) and five years (0.52±0.36), P=.01. Regarding cobalt, a statistically significant elevation is observed between six months and two years and a subsequent stabilization of values between two and five years, with a cobalt mean at six months (1.17±0.8) significantly lower than at two (2.63±1.76) and five years (2.84±2.1), P=.001. CONCLUSION Elevated serum cobalt levels have been observed in patients who underwent modular neck stem implantation. The results obtained in this study have limited the use of stems with a modular neck in our clinical practice.
Collapse
Affiliation(s)
- R E López
- Hospital Universitario Doctor Peset, Valencia, España.
| | - J M Pelayo de Tomás
- Hospital Universitario Doctor Peset, Valencia, España; Facultad de Medicina, Universidad de Valencia, Valencia, España
| | - M Morales Suárez Varela
- Unidad de Salud Pública, Higiene y Sanidad Ambiental, Departamento de Medicina Preventiva, Facultad de Farmacia, Universidad de Valencia, Burjassot, Valencia, España; Consorcio de Investigación Biomédica en Red de Epidemiología y Salud Pública, Madrid, España
| | - J L Rodrigo Pérez
- Hospital Universitario Doctor Peset, Valencia, España; Facultad de Medicina, Universidad de Valencia, Valencia, España
| |
Collapse
|
6
|
López RE, Pelayo de Tomás JM, Morales Suárez Varela M, Rodrigo Pérez JL. [Translated article] Evolution of chromium and cobalt serum levels after the use of a modular neck stem in primary total hip arthroplasty. Rev Esp Cir Ortop Traumatol (Engl Ed) 2024; 68:T26-T34. [PMID: 37992863 DOI: 10.1016/j.recot.2023.11.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Accepted: 05/29/2023] [Indexed: 11/24/2023] Open
Abstract
INTRODUCTION AND OBJECTIVES Modular neck primary stems were introduced with the theoretical advantage of restoring the hip anatomy more precisely. However, the presence of a second junction has been associated with increased corrosion and release of metal debris. The objective of our study is to quantify of chromium and cobalt serum values, and to analyse their temporal evolution during five years. MATERIAL AND METHODS We present a prospective series of 61 patients who underwent primary total hip arthroplasty by implantation of the H MAX-M® stem (Limacorporate, San Daniele, Italy). Serum chromium and cobalt determinations were performed at six months, two years and five years. RESULTS Our series shows a progressive elevation in chromium levels with a significant difference between chromium values at six months (0.35±0.18) and five years (0.52±0.36), p=.01. Regarding cobalt, a statistically significant elevation is observed between six months and two years and a subsequent stabilisation of values between two and five years, with a cobalt mean at six months (1.17±0.8) significantly lower than at two (2.63±1.76) and five years (2.84±2.1), p=.001. CONCLUSION Elevated serum cobalt levels have been observed in patients who underwent modular neck stem implantation. The results obtained in this study have limited the use of stems with a modular neck in our clinical practice.
Collapse
Affiliation(s)
- R E López
- Hospital Universitario Doctor Peset, Valencia, Spain.
| | - J M Pelayo de Tomás
- Hospital Universitario Doctor Peset, Valencia, Spain; Facultad de Medicina, Universidad de Valencia, Valencia, Spain
| | - M Morales Suárez Varela
- Unidad de Salud Pública, Higiene y Sanidad Ambiental, Departamento de Medicina Preventiva, Facultad de Farmacia, Universidad de Valencia, Burjassot, Valencia, Spain; Consorcio de Investigación Biomédica en Red de Epidemiología y Salud Pública, Madrid, Spain
| | - J L Rodrigo Pérez
- Hospital Universitario Doctor Peset, Valencia, Spain; Facultad de Medicina, Universidad de Valencia, Valencia, Spain
| |
Collapse
|
7
|
Moralidou M, Di Laura A, Hothi H, Henckel J, Hart AJ. Cemented or uncemented fixation: Which allows a more acceptable prosthetic femoral version in total hip arthroplasty? J Orthop Surg Res 2023; 18:948. [PMID: 38071336 PMCID: PMC10710710 DOI: 10.1186/s13018-023-04331-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/19/2023] [Accepted: 10/29/2023] [Indexed: 12/18/2023] Open
Abstract
BACKGROUND Three-dimensional computed-tomography (3D-CT) planning for primary Total Hip Arthroplasty (THA) typically uses the external femoral surface; as a result, it is difficult to predict the prosthetic femoral version (PFV) for uncemented femoral stems that press-fit to the internal surface of the bone. Cemented fixation allows the surgeon to adjust the version independent of the internal femoral anatomy. We aimed to better understand the effect of the fixation type on PFV. METHODS This was a case series study including a total of 95 consecutive patients (106 hips), who underwent uncemented (n = 81 hips) and cemented (n = 25 hips) primary THA using the posterior approach. The surgeon aimed for a PFV of 20°. Our primary objective was to compare PFV in both groups; our secondary objective was to evaluate the clinical outcomes. RESULTS The mean (± SD) PFV was 13° (± 9°) and 23° (± 8°) for the uncemented and cemented THA groups (P < 0.001), respectively. In the uncemented THA group, 36% of the patients had a PFV of < 10°. In the cemented THA group, this clinically important threshold dropped to 8%. Similarly, the Bland-Altman (BA) plots showed wider 95% limits of agreement for the uncemented group. Satisfactory clinical outcomes were recorded. CONCLUSION We found that the PFV was more clinically acceptable, for the posterior surgical approach, in the cemented group when compared to the uncemented group. Both THA groups reported high variability indicating the need to develop surgical tools to guide the PFV closer to the surgical target.
Collapse
Affiliation(s)
- Maria Moralidou
- Institute of Orthopaedics and Musculoskeletal Science, University College London, Brockley Hill, Stanmore, HA7 4LP, UK
| | - Anna Di Laura
- The Royal National Orthopaedic Hospital NHS Trust, Brockley Hill, Stanmore, HA7 4LP, UK
- Department of Mechanical Engineering, University College London, Torrington Place, London, WC1E 7JE, UK
| | - Harry Hothi
- The Royal National Orthopaedic Hospital NHS Trust, Brockley Hill, Stanmore, HA7 4LP, UK
- Department of Mechanical Engineering, University College London, Torrington Place, London, WC1E 7JE, UK
| | - Johann Henckel
- The Royal National Orthopaedic Hospital NHS Trust, Brockley Hill, Stanmore, HA7 4LP, UK
| | - Alister J Hart
- Institute of Orthopaedics and Musculoskeletal Science, University College London, Brockley Hill, Stanmore, HA7 4LP, UK.
- Cleveland Clinic London Hospital, 33 Grosvenor Pl, London, SW1X 7HY, UK.
| |
Collapse
|
8
|
López RE, Pelayo de Tomás JM, Morales Suárez Varela M, Rodrigo Pérez JL. Comparison of chromium and cobalt serum levels between a modular neck stem and its monoblock counterpart in primary total hip arthroplasty. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2023; 33:3403-3409. [PMID: 37140672 DOI: 10.1007/s00590-023-03567-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Accepted: 04/27/2023] [Indexed: 05/05/2023]
Abstract
BACKGROUND The addition of junctions in modular stems implies a greater susceptibility to corrosion. PURPOSE The aim of this study is to compare serum chromium and cobalt levels after using a bimodular stem and its monoblock counterpart in primary total hip arthroplasty. Postoperative clinical scores were also compared. PATIENTS AND METHODS A prospective cohort study between 2012 and 2015 was designed. One arm of the cohort included patients with the cementless modular neck stem H-Max M® and the other with the cementless monoblock stem counterpart H-Max S®. RESULTS No statistically significant difference was found in chromium value between groups (p = 0.621) at two years postoperative. Cobalt value was higher in the modular group (p = < 0.001). No statistically significant difference was found in clinical postoperative scores except for the Harris Hip Score, with better results at six months in modular group (p = 0.007). CONCLUSIONS Higher serum cobalt level in the modular group has limited the use of modular stems in our daily practice. Advantages of modular stem were not found. LEVEL OF EVIDENCE II.
Collapse
Affiliation(s)
- R E López
- Doctor Peset University Hospital, Av. Gaspar Aguilar 90, 46017, Valencia, Spain.
| | - J M Pelayo de Tomás
- Doctor Peset University Hospital, Av. Gaspar Aguilar 90, 46017, Valencia, Spain
- School of Medicine, Valencia University, Av. Blasco Ibañez, 15, 46010, Valencia, Spain
| | - M Morales Suárez Varela
- Unit of Public Health, Hygiene and Enviromental Health, Departament of Preventive Medicine and Public Health, Food Science, Toxicology and Legal Medicine, School of Pharmacy, Av. Vicente Andrés Estellés, Burjassot, Valencia, Spain
- CIBER of Epidemiology and Public Health (CIBERESP), Av. Monforte De Lemos 3-5, Pavillon 11, Floor 0, 28029, Madrid, Spain
| | - J L Rodrigo Pérez
- Doctor Peset University Hospital, Av. Gaspar Aguilar 90, 46017, Valencia, Spain
- School of Medicine, Valencia University, Av. Blasco Ibañez, 15, 46010, Valencia, Spain
| |
Collapse
|
9
|
Moralidou M, Di Laura A, Henckel J, Hart AJ. Can version of the proximal femur be used for CT planning uncemented femoral stems? Med Eng Phys 2023; 116:103985. [PMID: 37230697 DOI: 10.1016/j.medengphy.2023.103985] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 04/19/2023] [Accepted: 04/24/2023] [Indexed: 05/27/2023]
Abstract
Three-Dimensional Computed Tomography (3D-CT) planning can predict the prosthetic femoral size in uncemented primary Total Hip Arthroplasty (THA). Correct sizing usually results in optimal varus/valgus femoral alignment; however, its effect on the Prosthetic Femoral Version (PFV) is poorly understood. Most 3D-CT planning systems use Native Femoral Version (NFV) to plan PFV. We aimed to assess the relationship between PFV and NFV in primary uncemented THA using 3D-CT analysis. Pre- and post-operative CT data was retrospectively collected from 73 patients (81 hips) undergoing primary uncemented THA with a straight-tapered stem. 3D-CT models were used to measure PFV and NFV. The clinical outcomes were evaluated. The discrepancy between PFV and NFV was low (<5°) in 43%, moderate (5-10°) in 40%, high (10-15°) in 11% and very high (>15°) in 6% of the cases. We found that NFV is not a useable guide for planning PFV. The 95% limits of agreement were both high at 17° and 15°, respectively. Satisfactory clinical outcomes were recorded. The discrepancy was large enough to recommend against the use of NFV for planning PFV when using straight-tapered uncemented stems. Further work should focus on the internal bony anatomy and the influence of stem design when planning uncemented femoral stems.
Collapse
Affiliation(s)
- Maria Moralidou
- Institute of Orthopaedics and Musculoskeletal Science, University College London, Brockley Hill, Stanmore HA7 4LP, United Kingdom
| | - Anna Di Laura
- The Royal National Orthopaedic Hospital NHS Trust, Brockley Hill, Stanmore HA7 4LP, United Kingdom; Department of Mechanical Engineering, University College London, Torrington Place, London WC1E 7JE, United Kingdom
| | - Johann Henckel
- The Royal National Orthopaedic Hospital NHS Trust, Brockley Hill, Stanmore HA7 4LP, United Kingdom
| | - Alister J Hart
- Institute of Orthopaedics and Musculoskeletal Science, University College London, Brockley Hill, Stanmore HA7 4LP, United Kingdom; The Royal National Orthopaedic Hospital NHS Trust, Brockley Hill, Stanmore HA7 4LP, United Kingdom.
| |
Collapse
|
10
|
Schwartz Y, Sherwood DJ, Kamara E. Atypical Presentation of Periprosthetic Joint Infection With Pseudotumor With a Modular-Neck Stem Implant. Cureus 2022; 14:e28862. [PMID: 36225483 PMCID: PMC9537095 DOI: 10.7759/cureus.28862] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/06/2022] [Indexed: 11/25/2022] Open
Abstract
A 64-year-old male with a recalled modular-neck stem implant presented with a soft tissue mass in the lateral thigh. Preoperative testing revealed no signs of infection by the 2018 periprosthetic joint infection criteria. MRI revealed a large soft tissue mass around the implant consistent with a pseudotumor, and we performed revision surgery of the femoral component for trunnionosis. One intraoperative culture was positive for infection, and the patient was placed on antibiotics. Six weeks following revision surgery of the femoral component, the patient presented with acute drainage and was diagnosed with an acute on chronic periprosthetic joint infection and underwent explantation of the femoral and acetabular components with the placement of an antibiotic spacer. Cultures revealed identical bacteria from the index procedure. Given the clinical course, this case likely represents adverse local tissue reaction with an atypical presentation of periprosthetic joint infection. This is the first case presentation of an adverse local tissue reaction and superimposed periprosthetic joint infection with normal infection workup, representing an important consideration when differentiating between pseudotumor and periprosthetic joint infection in modular-neck femoral stem implants.
Collapse
|
11
|
Matsushita Y, Otani T, Hayama T, Fujii H, Kawaguchi Y, Saito M. A Modified Modular Stem in Primary Total Hip Arthroplasty for Developmental Dysplasia of the Hip: Average 11-year Follow-Up in Cases With Previously Reported 3-year Clinical Results. J Arthroplasty 2022; 37:1832-1838. [PMID: 35469988 DOI: 10.1016/j.arth.2022.04.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Revised: 04/14/2022] [Accepted: 04/18/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Modular stems require careful follow-up, especially after any design modification. This study investigated the mid- to long-term outcomes of total hip arthroplasty in patients with developmental dysplasia of the hip using the S-ROM-A stem, a modified S-ROM stem for Asians. METHODS We previously reported short-term outcomes for all 220 dysplastic hips that underwent primary total hip arthroplasty with the S-ROM-A stem. Here, we followed the clinical and radiological outcomes of 201 of the 220 hips (91%) for a mean 11.4 years postoperatively. We also performed multivariate analysis to determine whether large anteversion angle adjustment was associated with increased osteolysis. RESULTS The cumulative survival rate of the stem at 168 months postoperatively was 97.4%. Two hips underwent revision surgery, including 1 due to neck trunnionosis. Characteristic distal stem fracture occurred in 3 hips (1.5%). Most partial radiolucent lines observed around the sleeve early postoperatively disappeared by 7 years, postoperatively. Mild osteolysis occurred relatively frequently (20%), but a multivariate model adjusted for polyethylene type showed no significant association between the occurrence of osteolysis and anteversion adjustment of the modular stem (stem anteversion decreased ≤-20°, P = .829; stem anteversion increased ≥+20°, P = .619). CONCLUSION Partial radiolucent lines early postoperatively do not affect long-term outcomes. The clinical benefits of actively adjusting the stem anteversion angle outweigh the mechanical risks. Mild osteolysis, stem fracture, and trunnionosis were relatively frequent complications. Analysis with longer follow-up and more cases are necessary to clearly determine if these complications are associated with the design modification.
Collapse
Affiliation(s)
- Yohei Matsushita
- Department of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Takuya Otani
- Department of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Tetsuo Hayama
- Department of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Hideki Fujii
- Department of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Yasuhiko Kawaguchi
- Department of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan
| | - Mitsuru Saito
- Department of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan
| |
Collapse
|
12
|
Shoji T, Inoue T, Kato Y, Fujiwara Y, Sumii J, Shozen H, Adachi N. Associations between implant alignment or position and patient-reported outcomes after total hip arthroplasty. Clin Biomech (Bristol, Avon) 2022; 97:105701. [PMID: 35696828 DOI: 10.1016/j.clinbiomech.2022.105701] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 05/18/2022] [Accepted: 06/01/2022] [Indexed: 02/07/2023]
Abstract
BACKGROUND We aimed to evaluate the associations between implant alignment/position and patient-reported outcomes following total hip arthroplasty using CT-based simulation software. METHODS We reviewed hips of 137 patients (27 males, 110 females, mean age: 67.3 years old) who underwent total hip arthroplasty. Radiographic evaluations were based on the software for evaluation of the parameters related to implant alignment/position and femoral/3-dimensional offset using post-operative CT data. Pre-operative and one-year post-operative patient-reported outcomes using Japanese Orthopaedic Association Hip Disease Evaluation Questionnaire scores were evaluated. FINDINGS The total and movement scores of normal combined anteversion and stem anteversion angle groups were significantly higher than those of lower and higher groups. The pain and movement scores of decreased femoral offset group were significantly lower than those of restored and increased femoral offset group. There were no significant differences in all scores in cup inclination and anteversion angle, stem coronal alignment, and 3-dimensional femoral offset among groups. Moreover, investigation of the associations between combined anteversion angle/stem anteversion/femoral offset and movement scores revealed that combined anteversion angle and stem anteversion were significantly associated with the movement that needs deep hip flexion and occasionally deep abduction, and high femoral offset was also associated with the movement that needs deep hip flexion. INTERPRETATION Surgeons should consider the stem anteversion, stem sagittal alignment, and combined anteversion, in addition to the femoral offset to achieve patient's post-operative satisfaction, although the surgeon may have a relatively larger choice for the implant positioning, especially on the cup side.
Collapse
Affiliation(s)
- Takeshi Shoji
- Department of Artificial Joints and Biomaterials, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan; Department of Orthopaedic Surgery, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan.
| | - Tadashi Inoue
- Department of Orthopaedic Surgery, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| | - Yuichi Kato
- Department of Orthopaedic Surgery, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| | - Yusuke Fujiwara
- Department of Orthopaedic Surgery, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| | - Junichi Sumii
- Department of Orthopaedic Surgery, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| | - Hideki Shozen
- Department of Orthopaedic Surgery, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| | - Nobuo Adachi
- Department of Orthopaedic Surgery, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| |
Collapse
|
13
|
López R, Pelayo de Tomás J, Morales Suárez Varela M, Rodrigo Pérez J. [Translated article] Comparison of leg length discrepancy correction after the use of a modular neck stem and its monoblock homologue in total primary hip arthroplasty. Rev Esp Cir Ortop Traumatol (Engl Ed) 2022; 66:T27-T35. [DOI: 10.1016/j.recot.2022.07.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2021] [Accepted: 01/18/2022] [Indexed: 11/29/2022] Open
|
14
|
Relative Femoral Neck Lengthening in Legg-Calvé-Perthes Total Hip Arthroplasty. Arthroplast Today 2022; 15:61-67. [PMID: 35399986 PMCID: PMC8991231 DOI: 10.1016/j.artd.2022.02.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Revised: 01/16/2022] [Accepted: 02/12/2022] [Indexed: 11/20/2022] Open
Abstract
Background Total hip replacement (THR) in patients with a history of Legg-Calvé-Perthes disease can be a technically challenging procedure due to the distorted hip morphology. We propose a technique in which THR is preceded by a modified relative femoral neck lengthening (RFNL) procedure. Hereby, we aim to restore the biomechanical parameters. Methods Twenty-eight patients underwent RFNL in preparation of a second-stage THR between December 2011 and September 2019. The mean age was 38.1 ± 11.4 years. Radiographs were analyzed for centrotrochanteric distance, lateral displacement of the greater trochanter, and leg length discrepancy to assess the biomechanical restoration. Complication rate, reoperation rate, and patient-reported outcome measures were measured. Results Mean centrotrochanteric distance increased from −18.7 ± 6.7 mm preoperatively to 1.9 ± 9.0 mm (P < .001) after RFNL and to 11.4 ± 10.4 mm after THR (P < .001). Mean lateral displacement of the greater trochanter increased from 34.2 ± 8.1 mm preoperatively to 42.4 ± 5.2 mm (P < .001) after RFNL and to 49.9 ± 8.3 mm after THR (P < .001). Leg length discrepancy decreased from 17.5 ± 10.5 mm to 2.7 ± 2.2 mm after THR (P < .001). Mean Harris Hip Score improved from 56.9 ± 17.6 preoperatively to 89.4 ± 10.7 at the latest follow-up (P < .001). Eight patients (8 hips) postponed THR because of sufficient clinical improvement, at a mean follow-up of 4.2 ± 2.1 years. Two hips needed a revision RFNL due to non-union (7.1%), and 1 hip replacement was revised due to a deep infection (5.0%). Conclusions RFNL prior to THR in patients with end-stage osteoarthritis following Legg-Calvé-Perthes disease allows for utilizing regular implants with straight access to the femoral canal, with restored biomechanics and restoration of leg length. The prominent overhanging greater trochanter is reduced to prevent postoperative extra-articular impingement.
Collapse
|
15
|
Zinner M, Schroeder L, Pumilia CA, Lee EK, Martin G. THA with Use of Patient-Specific Resurfacing Jigs and a Novel Customized Implant Design. JBJS Rev 2022; 10:01874474-202205000-00008. [PMID: 36995410 DOI: 10.2106/jbjs.rvw.21.00078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
» Conventional total hip arthroplasty (THA) largely remains an unguided procedure dependent on the ability and experience of the surgeon. New technologies, such as patient-specific instrumentation and robotics, have shown promising results in improving implant positioning, which has the potential to improve patient outcomes. » The use of off-the-shelf (OTS) implant designs, however, limits the success of the technological advances since they are unable to recreate the native anatomy of the joint. The inability to restore femoral offset and version or the presence of implant-related leg-length discrepancies often lead to suboptimal surgical results that increase the risk of dislocation, fractures, and component wear, compromising postoperative functional outcomes and implant longevity. » A customized THA system, whereby the femoral stem is designed to restore patient anatomy, has recently been introduced. The THA system uses computed tomography (CT)-derived 3D imaging to create a custom stem, patient-specific component placement, and patient-specific instrumentation that matches the patient's native anatomy. » The purpose of this article is to provide information on the design and manufacturing process of this new THA implant, to illustrate the associated preoperative planning, and to describe the surgical technique; 3 surgical cases are presented.
Collapse
Affiliation(s)
- Matthew Zinner
- Charles E. Schmidt College of Medicine, Boca Raton, Florida
| | - Lennart Schroeder
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Munich, Germany
| | - Cyrus A Pumilia
- College of Medicine, University of Central Florida, Orlando, Florida
| | - Eric K Lee
- Department of Orthopedic Surgery, Personalized Orthopaedics of the Palm Beaches, Boynton Beach, Florida
| | - Gregory Martin
- College of Medicine, University of Central Florida, Orlando, Florida
- Department of Orthopedic Surgery, Personalized Orthopaedics of the Palm Beaches, Boynton Beach, Florida
- University of Miami Leonard M. Miller School of Medicine, Miami, Florida
| |
Collapse
|
16
|
López R, Pelayo de Tomás J, Morales Suárez Varela M, Rodrigo Pérez J. Comparación de la corrección de la discrepancia de longitud de miembros tras el empleo de un vástago con cuello modular y su homólogo monobloque en la artroplastia total de cadera primaria. Rev Esp Cir Ortop Traumatol (Engl Ed) 2022; 66:445-453. [DOI: 10.1016/j.recot.2022.01.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2021] [Revised: 01/03/2022] [Accepted: 01/18/2022] [Indexed: 12/01/2022] Open
|
17
|
Huber G, Morlock MM. Which length should the neck segment of modular revision stems have? Clin Biomech (Bristol, Avon) 2022; 94:105286. [PMID: 33678413 DOI: 10.1016/j.clinbiomech.2021.105286] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/04/2020] [Revised: 01/12/2021] [Accepted: 01/27/2021] [Indexed: 02/07/2023]
Abstract
BACKGROUND Fractures of modular revision stems at the taper junction are rare but severe clinical problems. The purpose of this study was the estimation of taper loading to identify configurations which are less prone to failure. METHODS A parametrical analytical 3-D model was developed to determine the influence of neck segment length, offset and anteversion on the loading at the modular taper junction between neck segment and stem. Published in-vivo hip joint forces were used to simulate different activities. FINDINGS No unique ideal neck segment length can be specified due to the differences in loading magnitude and direction between activities. The best neck segment length for walking is longer than for high loading activities as stair climbing and jogging. A medium length between 70 mm and 90 mm appears to be a good compromise. A shorter offset (37 mm vs. 47 mm) reduces the stress by about 25% for walking and jogging. Retroverted implantation by 5° increases the loading whereas an anteverted implantation by 5° reduces it. A high offset (47 mm) combined with a short neck segment length (50 mm) reaches about 80% of the taper yield strength for jogging (taper diameter 13 mm). INTERPRETATION Simplified 2-D modelling falsely predicts no bending at the taper junction for a long neck segment, whereas the 3-D model shows substantial stress load along the whole stem length. Stem tapers of short as well as very long neck segments are higher risk for failure. Neck segment length should lie in the range between 70 mm and 90 mm.
Collapse
Affiliation(s)
- Gerd Huber
- Institute of Biomechanics, TUHH Hamburg University of Technology, Denickestraße 15, 21073 Hamburg, Germany.
| | - Michael M Morlock
- Institute of Biomechanics, TUHH Hamburg University of Technology, Denickestraße 15, 21073 Hamburg, Germany
| |
Collapse
|
18
|
López R, Gómez Aparicio S, Pelayo de Tomás J, Morales Suárez Varela M, Rodrigo Pérez J. [Translated article] Comparison of the correction of the femoral offset after the use of a stem with modular neck and its monoblock homologue in total primary hip arthroplasty. Rev Esp Cir Ortop Traumatol (Engl Ed) 2022. [DOI: 10.1016/j.recot.2022.01.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
19
|
Comparación de la corrección del offset femoral tras el empleo de un vástago monobloque y un vástago con cuello modular en la artroplastia total de cadera primaria. Rev Esp Cir Ortop Traumatol (Engl Ed) 2022; 66:77-85. [DOI: 10.1016/j.recot.2021.08.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2021] [Revised: 07/23/2021] [Accepted: 08/02/2021] [Indexed: 11/21/2022] Open
|
20
|
Ishii S, Homma Y, Matsukawa T, Baba T, Kubota A, Yokoyama K, Kaneko K, Ishijima M. Horror of three synergistic factors in THA: high mechanical stress, dissimilar metals, low elasticity stem: a case report. ARTHROPLASTY 2021; 3:39. [PMID: 35236468 PMCID: PMC8796415 DOI: 10.1186/s42836-021-00091-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Accepted: 08/06/2021] [Indexed: 02/08/2023] Open
Abstract
Background A large-diameter femoral head is effective in preventing dislocation after total hip arthroplasty. However, although rare, catastrophic stem tribocorrosion may occur at the head-stem junction. Case presentation A 70-year-old woman underwent revision surgery 7.5 years after total hip arthroplasty because of catastrophic stem corrosion with dissociation of the metal head (cobalt/chromium) and stem (TiMo12Zr6Fe2). Abnormal levels of cobalt were found in the intra-articular fluid, capsule, hip muscle, and blood. Revision surgery was performed via the direct anterior approach. The well-fixed femoral stem was explanted, and a cemented stainless stem with stainless head was implanted. Three months after the revision surgery, the cobalt concentration in the blood had decreased to normal. Conclusions Stem dissociation in the present case might have been caused by synergistic combination of a 36-mm-diameter femoral head and long neck length offset with high frictional torque, a cobalt-chromium head with a high risk of galvanic corrosion, and a TMZF (TiMo12Zr6Fe2) alloy stem with a low Young’s modulus of elasticity. The combination of these factors must be avoided.
Collapse
|
21
|
Gawhale S, Bansal S, Yadav A, Mishra S, Akshay KS, Chikodi A. Total Hip Arthroplasty after McMurray's Osteotomy - A Case Report and Review of Literature. J Orthop Case Rep 2021; 11:97-99. [PMID: 34327175 PMCID: PMC8310638 DOI: 10.13107/jocr.2021.v11.i04.2168] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Introduction: Total hip arthroplasty after McMurray’s osteotomy increases the operative difficulties and decreases the chances of better outcome. With the advent of modular femoral stems, minute changes can be done to individual joints, which allow intraoperative flexibility and better post-operative outcome. Thus, it should be considered as an option for complicated cases. Case Report: We report a case of a 35-year-old female with chief complain of pain in the left hip while walking for the past 2 years. The patient also had difficulty in squatting and sitting cross legged. History of fracture in the left hip at 4 years of age for which McMurray’s osteotomy was done. The patient was operated with total hip arthroplasty using modular Sivash range of motion (S-ROM) stem. Conclusion: Modular S-ROM total hip arthroplasty is a good option for treatment in cases with previous osteotomy in femur.
Collapse
Affiliation(s)
- Sangeet Gawhale
- Department of Orthopaedics, Grant Medical College and Sir J.J. Group of Hospitals, Mumbai, Maharashtra, India
| | - Sagar Bansal
- Department of Orthopaedics, Grant Medical College and Sir J.J. Group of Hospitals, Mumbai, Maharashtra, India
| | - Amit Yadav
- Department of Orthopaedics, Grant Medical College and Sir J.J. Group of Hospitals, Mumbai, Maharashtra, India
| | - Shaswat Mishra
- Department of Orthopaedics, Grant Medical College and Sir J.J. Group of Hospitals, Mumbai, Maharashtra, India
| | - K S Akshay
- Department of Orthopaedics, Grant Medical College and Sir J.J. Group of Hospitals, Mumbai, Maharashtra, India
| | - Angad Chikodi
- Department of Orthopaedics, Grant Medical College and Sir J.J. Group of Hospitals, Mumbai, Maharashtra, India
| |
Collapse
|
22
|
Eichenbaum G, Wilsey JT, Fessel G, Qiu QQ, Perkins L, Hasgall P, Monnot A, More SL, Egnot N, Sague J, Marcello S, Connor K, Scutti J, Christian WV, Coplan PM, Wright J, Hastings B, Katz LB, Vreeke M, Calistri-Yeh M, Faiola B, Purushothaman B, Nevelos J, Bashiri M, Christensen JB, Kovochich M, Unice K. An integrated benefit-risk assessment of cobalt-containing alloys used in medical devices: Implications for regulatory requirements in the European Union. Regul Toxicol Pharmacol 2021; 125:105004. [PMID: 34256083 DOI: 10.1016/j.yrtph.2021.105004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Revised: 05/27/2021] [Accepted: 07/09/2021] [Indexed: 11/15/2022]
Abstract
In 2017, the European Union (EU) Committee for Risk Assessment (RAC) recommended the classification of metallic cobalt (Co) as Category 1B with respect to its carcinogenic and reproductive hazard potential and Category 2 for mutagenicity but did not evaluate the relevance of these classifications for patients exposed to Co-containing alloys (CoCA) used in medical devices. CoCA are inherently different materials from Co metal from a toxicological perspective and thus require a separate assessment. CoCA are biocompatible materials with a unique combination of properties including strength, durability, and a long history of safe use that make them uniquely suited for use in a wide-range of medical devices. Assessments were performed on relevant preclinical and clinical carcinogenicity and reproductive toxicity data for Co and CoCA to meet the requirements under the EU Medical Device Regulation triggered by the ECHA re-classification (adopted in October 2019 under the 14th Adaptation to Technical Progress to CLP) and to address their relevance to patient safety. The objective of this review is to present an integrated overview of these assessments, a benefit-risk assessment and an examination of potential alternative materials. The data support the conclusion that the exposure to CoCA in medical devices via clinically relevant routes does not represent a hazard for carcinogenicity or reproductive toxicity. Additionally, the risk for the adverse effects that are known to occur with elevated Co concentrations (e.g., cardiomyopathy) are very low for CoCA implant devices (infrequent reports often reflecting a unique catastrophic failure event out of millions of patients) and negligible for CoCA non-implant devices (not measurable/no case reports). In conclusion, the favorable benefit-risk profile also in relation to possible alternatives presented herein strongly support continued use of CoCA in medical devices.
Collapse
Affiliation(s)
- Gary Eichenbaum
- Johnson & Johnson, 410 George St, New Brunswick, NJ, 08901, USA
| | - Jared T Wilsey
- Smith & Nephew, 1450 E Brooks Rd, Memphis, TN, 38116, USA
| | - Gion Fessel
- Smith & Nephew, Oberneuhofstasse 10D, 6340, Baar, Switzerland
| | - Qing-Qing Qiu
- Stryker, 2825 Airview Boulevard, Kalamazoo, MI, 49002, USA
| | - Laura Perkins
- Abbott Vascular, 3200 Lakeside Dr, Santa Clara, CA, 95054, USA
| | | | - Andrew Monnot
- Cardno ChemRisk, 235 Pine Street Suite 2300, San Francisco, CA, 94104, USA
| | - Sharlee L More
- Cardno ChemRisk, 6720 S Macadam Ave Suite 150, Portland, OR, 97219, USA
| | - Natalie Egnot
- Cardno ChemRisk, 20 Stanwix Street Suite 505, Pittsburgh, PA, 15222, USA
| | - Jorge Sague
- Stryker, 2825 Airview Boulevard, Kalamazoo, MI, 49002, USA
| | | | - Kevin Connor
- Boston Scientific, 100 Boston Scientific Way, Marlborough, MA, 01752, USA
| | - James Scutti
- Boston Scientific, 100 Boston Scientific Way, Marlborough, MA, 01752, USA
| | | | - Paul M Coplan
- Johnson & Johnson, 410 George St, New Brunswick, NJ, 08901, USA; University of Pennsylvania, Perelman School of Medicine, Philadelphia, PA, 19104, USA
| | - John Wright
- Johnson & Johnson, 410 George St, New Brunswick, NJ, 08901, USA
| | - Bob Hastings
- Johnson & Johnson, 410 George St, New Brunswick, NJ, 08901, USA
| | - Laurence B Katz
- LifeScan Global Corporation, 20 Valley Stream Parkway, Malvern, PA, 19355, USA
| | - Mark Vreeke
- Edwards Lifesciences, One Edwards Way, Irvine, CA, 92614, USA
| | | | - Brenda Faiola
- Becton Dickinson, 1 Becton Drive, Franklin Lakes, NJ, 07417, USA; Rho, Inc., 2635 E NC Hwy 54, Durham, NC, 27713, USA
| | | | - Jim Nevelos
- Stryker, 2825 Airview Boulevard, Kalamazoo, MI, 49002, USA
| | - Mehran Bashiri
- Stryker Neurovascular, 47900 Bayside Parkway, Fremont, CA, 94538, USA
| | | | - Michael Kovochich
- Cardno ChemRisk, 30 North LaSalle St Suite 3910, Chicago, Illinois, 60602-2590, USA
| | - Kenneth Unice
- Cardno ChemRisk, 20 Stanwix Street Suite 505, Pittsburgh, PA, 15222, USA.
| |
Collapse
|
23
|
Dual Modular Titanium Alloy Femoral Stem Failure Mechanisms and Suggested Clinical Approaches. MATERIALS 2021; 14:ma14113078. [PMID: 34199983 PMCID: PMC8200202 DOI: 10.3390/ma14113078] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 05/27/2021] [Accepted: 06/02/2021] [Indexed: 12/13/2022]
Abstract
Titanium (Ti) alloys have been proven to be one of the most suitable materials for orthopaedic implants. Dual modular stems have been introduced to primary total hip arthroplasty (THA) to enable better control of the femoral offset, leg length, and hip stability. This systematic review highlights information acquired for dual modular Ti stem complications published in the last 12 years and offers a conclusive discussion of the gathered knowledge. Articles referring to dual modular stem usage, survivorship, and complications in English were searched from 2009 to the present day. A qualitative synthesis of literature was carried out, excluding articles referring solely to other types of junctions or problems with cobalt-chromium alloys in detail. In total, 515 records were identified through database searching and 78 journal articles or conference proceedings were found. The reasons for a modular neck fracture of a Ti alloy are multifactorial. Even though dual modular stems have not shown any clinical benefits for patients and have been associated with worse results regarding durability than monolithic stems, some designs are still marketed worldwide. Orthopaedic surgeons should use Ti6Al4V dual modular stem designs for primary THA in special cases only.
Collapse
|
24
|
McAleese T, Feeley I, Hughes A, Sheehan E, Merghani K, Niall D. Bilateral Mechanically-Assisted Crevice Corrosion Resulting in Femoral Stem-Head Dissociation in Metal-on-Polyethylene Total Hip Arthroplasty. Arthroplast Today 2021; 8:35-39. [PMID: 33718553 PMCID: PMC7921711 DOI: 10.1016/j.artd.2020.12.018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Revised: 12/10/2020] [Accepted: 12/16/2020] [Indexed: 11/30/2022] Open
Abstract
There are emerging reports of complications related to corrosion in modular femoral components. We report a unique case describing an 83-year-old man with bilateral mechanically-assisted crevice corrosion in hip replacements performed 10 years previously, by the same surgeon using the same size 3 Accolade TMZF stem and same 44-mm CoCr LFIT V40 head (Stryker Orthopedics, Mahwah NJ). Our patient presented with complete femoral stem-head complex dissociation of his right hip and elevated serum cobalt and chromium levels. He subsequently underwent right hip revision arthroplasty while his contralateral hip is monitored closely as an outpatient. This case helps to define the poorly understood mechanisms and component design factors implicated in this emerging issue. We also hope to provoke discussions about guidelines for monitoring and revising failing metal-on-polyethylene arthroplasty systems.
Collapse
Affiliation(s)
- Timothy McAleese
- Department of Trauma and Orthopaedics, Midland Regional Hospital Tullamore, Tullamore, Ireland
- Corresponding author. Tullamore Hospital, Arden Road, Tullamore, Co Offaly, Ireland.
| | - Iain Feeley
- Department of Trauma and Orthopaedics, Midland Regional Hospital Tullamore, Tullamore, Ireland
| | - Andrew Hughes
- Department of Trauma and Orthopaedics, Midland Regional Hospital Tullamore, Tullamore, Ireland
| | - Eoin Sheehan
- Department of Trauma and Orthopaedics, Midland Regional Hospital Tullamore, Tullamore, Ireland
- Medical School, University of Limerick, Limerick, Ireland
| | - Khalid Merghani
- Department of Trauma and Orthopaedics, Midland Regional Hospital Tullamore, Tullamore, Ireland
- Medical School, University of Limerick, Limerick, Ireland
| | - Dorothy Niall
- Department of Trauma and Orthopaedics, Midland Regional Hospital Tullamore, Tullamore, Ireland
- Medical School, University of Limerick, Limerick, Ireland
| |
Collapse
|
25
|
A Crevice Corrosion Model for Biomedical Trunnion Geometries and Surfaces Feature. MATERIALS 2021; 14:ma14041005. [PMID: 33672713 PMCID: PMC7924358 DOI: 10.3390/ma14041005] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Revised: 02/12/2021] [Accepted: 02/16/2021] [Indexed: 11/16/2022]
Abstract
Modular hip joint implants were introduced in arthroplasty medical procedures because they facilitate the tailoring of patients' anatomy, the use of different materials in one single configuration, as well as medical revision. However, in certain cases, such prostheses may undergo deterioration at the head-neck junctions with negative clinical consequences. Crevice-corrosion is commonly invoked as one of the degradation mechanisms acting at those junctions despite biomedical alloys such as Ti6Al4V and CoCr being considered generally resistant to this form of corrosion. To verify the occurrence of crevice corrosion in modular hip joint junctions, laboratory crevice-corrosion tests were conducted in this work under hip joint-relevant conditions, i.e., using similar convergent crevice geometries, materials (Ti6Al4V and CoCr alloys vs. ceramic), surface finish, NaCl solution pHs (5.6 and 2.3), and electrochemical conditions. A theoretical model was also developed to describe crevice-corrosion considering relevant geometrical and electrochemical parameters. To verify the model, a FeCr alloy, known to be sensitive to this phenomenon, was subjected to the crevice-corrosion test in sulfuric acid. The experiments and the model predictions clearly showed that, in principle, crevice corrosion of Ti6Al4V or CoCr is not supposed to occur in typical crevices formed at the stem-neck junction of hip implants.
Collapse
|
26
|
Ilo KC, Aboelmagd K, Hothi HS, Asaad A, Skinner JA, Hart AJ. Does modularity of metal-on-metal hip implants increase cobalt: chromium ratio? Hip Int 2021; 31:109-114. [PMID: 31496282 DOI: 10.1177/1120700019873637] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Blood metal ion levels are used in the surveillance of metal-on-metal (MoM) hip implants. Modular implants contain an extra source of metal debris that may affect the ratio of metal ions in the blood. METHODS This was a retrospective study of 503 patients with hip replacements made by a single manufacturer (Smith & Nephew, Warwick, UK) with the same bearing surface. There were 54 total hip arthroplasties, 35 Birmingham Mid-Head Resections and 414 hip resurfacings. Whole blood metal ion levels and their ratios were analysed to investigate the effect of a modular junction. RESULTS The cobalt:chromium ratios were greater in the total hip arthroplasty group (mean 2.3:1) when compared to the resurfacings group (mean 1.3:1, p = <0.05) and Birmingham Mid-Head Resection group (mean 1.1:1, p = 0.11). CONCLUSIONS This study demonstrated a trend for a higher cobalt:chromium ratio in patients with MoM total hip replacement that may be due to metal debris from the modular stem-head junction. Further work is required to correlate clinical data with retrieval analysis to confirm the effect of taper material loss on the cobalt:chromium ratio.
Collapse
Affiliation(s)
- Kevin C Ilo
- Institute of Orthopaedics and Musculoskeletal Science (University College London), Royal National Orthopaedic Hospital, Stanmore, Middlesex, UK
| | - Karim Aboelmagd
- Institute of Orthopaedics and Musculoskeletal Science (University College London), Royal National Orthopaedic Hospital, Stanmore, Middlesex, UK
| | - Harry S Hothi
- Institute of Orthopaedics and Musculoskeletal Science (University College London), Royal National Orthopaedic Hospital, Stanmore, Middlesex, UK
| | - Asaad Asaad
- Institute of Orthopaedics and Musculoskeletal Science (University College London), Royal National Orthopaedic Hospital, Stanmore, Middlesex, UK
| | - John A Skinner
- Institute of Orthopaedics and Musculoskeletal Science (University College London), Royal National Orthopaedic Hospital, Stanmore, Middlesex, UK
| | - Alister J Hart
- Institute of Orthopaedics and Musculoskeletal Science (University College London), Royal National Orthopaedic Hospital, Stanmore, Middlesex, UK
| |
Collapse
|
27
|
Moralidou M, Di Laura A, Henckel J, Hothi H, Hart AJ. Three-dimensional pre-operative planning of primary hip arthroplasty: a systematic literature review. EFORT Open Rev 2020; 5:845-855. [PMID: 33425373 PMCID: PMC7784139 DOI: 10.1302/2058-5241.5.200046] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
Three-dimensional (3D) pre-operative planning in total hip arthroplasty (THA) is being recognized as a useful tool in planning elective surgery, and as crucial to define the optimal component size, position and orientation. The aim of this study was to systematically review the existing literature for the use of 3D pre-operative planning in primary THA.A systematic literature search was performed using keywords, through PubMed, Scopus and Google Scholar, to retrieve all publications documenting the use of 3D planning in primary THA. We focussed on (1) the accuracy of implant sizing, restoration of hip biomechanics and component orientation; (2) the benefits and barriers of this tool; and (3) current gaps in literature and clinical practice.Clinical studies have highlighted the accuracy of 3D pre-operative planning in predicting the optimal component size and orientation in primary THAs. Component size planning accuracy ranged between 34-100% and 41-100% for the stem and cup respectively. The absolute, average difference between planned and achieved values of leg length, offset, centre of rotation, stem version, cup version, inclination and abduction were 1 mm, 1 mm, 2 mm, 4°, 7°, 0.5° and 4° respectively.Benefits include 3D representation of the human anatomy for precise sizing and surgical execution. Barriers include increased radiation dose, learning curve and cost. Long-term evidence investigating this technology is limited.Emphasis should be placed on understanding the health economics of an optimized implant inventory as well as long-term clinical outcomes. Cite this article: EFORT Open Rev 2020;5:845-855. DOI: 10.1302/2058-5241.5.200046.
Collapse
Affiliation(s)
- Maria Moralidou
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, UK
| | - Anna Di Laura
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, UK
| | - Johann Henckel
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, UK
| | - Harry Hothi
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, UK
| | - Alister J Hart
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, UK
| |
Collapse
|
28
|
Long-Term Results of Revision Total Hip Arthroplasty Using a Modern Extensively Porous-Coated Femoral Stem. J Arthroplasty 2020; 35:3697-3702. [PMID: 32713726 DOI: 10.1016/j.arth.2020.06.052] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 06/08/2020] [Accepted: 06/17/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND The use of an extensively porous-coated uncemented cobalt-chrome monoblock femoral stem for revision total hip arthroplasty (THA) is well established with excellent mid-term results. The aim of this study is to report the long-term survivorship of these implants in femoral stem revisions. METHODS This is a long-term retrospective review of prospectively collected data of 55 femoral stem revisions in 55 patients using a contemporary, cementless extensively porous-coated cobalt-chrome monoblock stem. All patients between 2001 and 2006 who underwent first time femoral stem revision with a contemporary, cementless extensively porous-coated cobalt-chrome monoblock stem were included. Harris Hip Score, Western Ontario and McMaster Universities Index, and University of California Los Angeles activity scores were recorded preoperatively and at latest follow-up. Radiographs were analyzed for evidence of loosening, subsidence, osteolysis, and bony union. This study included 55 patients, comprising of 36 females (66%) and 19 males (34%) with a mean age of 66.4 ± 9.3 years at the time of surgery. The mean time interval from index procedure was 9.8 ± 2.9 years. Mean time from revision THA to final follow-up was 13.2 ± 2.17 years with a minimum of 10 years of follow-up. RESULTS Indications for revision included aseptic loosening (33), prosthetic joint infection (13), and periprosthetic fracture (10). Significant improvement in Harris Hip Score (85.1 ± 1.77 vs 51.8 ± 2.3, P < .001), Western Ontario and McMaster Universities Index (17.6 ± 0.77 vs 33.3 ± 0.8, P < .001), and University of California Los Angeles (5.25 ± 0.2 vs 2.7 ± 0.36, P < .001) scores were found at latest follow-up compared to preoperative. Fifty-four patients (98%) achieved stable bony ingrowth on radiographic analysis. All 10 patients treated for periprosthetic fractures achieved bony union of their fractures. Two patients suffered intraoperative periprosthetic fractures and were treated with a cable-plating system. There were no mechanical failures and no femoral stem re-revisions. One patient was diagnosed with a deep infection and was treated with chronic suppressive antibiotic therapy due to significant medical comorbidities. CONCLUSION Revision of the femoral component with a contemporary extensively porous-coated cobalt-chrome femoral stem has excellent functional outcomes, radiographic outcomes, and long-term survivorship with minimal complications.
Collapse
|
29
|
Kheir MM, Drayer NJ, Chen AF. An Update on Cementless Femoral Fixation in Total Hip Arthroplasty. J Bone Joint Surg Am 2020; 102:1646-1661. [PMID: 32740265 DOI: 10.2106/jbjs.19.01397] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Affiliation(s)
- Michael M Kheir
- Department of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis, Indiana
| | - Nicholas J Drayer
- Department of Orthopaedic Surgery, Madigan Army Medical Center, Tacoma, Washington
| | - Antonia F Chen
- Department of Orthopaedic Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
30
|
Inaccurate offset restoration in total hip arthroplasty results in reduced range of motion. Sci Rep 2020; 10:13208. [PMID: 32764592 PMCID: PMC7413373 DOI: 10.1038/s41598-020-70059-1] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2019] [Accepted: 07/14/2020] [Indexed: 02/08/2023] Open
Abstract
Offset restoration in total hip arthroplasty (THA) is associated with postoperative range of motion (ROM) and gait kinematics. We aimed to research into the impact of high offset (HO) and standard stems on postoperative ROM. 121 patients received cementless THA through a minimally-invasive anterolateral approach. A 360° hip ROM analysis software calculated impingement-free hip movement based on postoperative 3D-CTs compared to ROM values necessary for activities of daily living (ADL). The same model was then run a second time after changing the stem geometry between standard and HO configuration with the implants in the same position. HO stems showed higher ROM for all directions between 4.6 and 8.9° (p < 0.001) compared with standard stems but with high interindividual variability. In the subgroup with HO stems for intraoperative offset restoration, the increase in ROM was even higher for all ROM directions with values between 6.1 and 14.4° (p < 0.001) compared to offset underrestoration with standard stems. Avoiding offset underrestoration resulted in a higher amount of patients of over 20% for each ROM direction that fulfilled the criteria for ADL (p < 0.001). In contrast, in patients with standard stems for offset restoration ROM did increase but not clinically relevant by offset overcorrection for all directions between 3.1 and 6.1° (p < 0.001). Offset overcorrection by replacing standard with HO stems improved ROM for ADL in a low number of patients below 10% (p > 0.03). Patient-individual restoration of offset is crucial for free ROM in THA. Both over and underrestoration of offset should be avoided.
Collapse
|
31
|
Talmo CT, Robbins CE, Siddiqi A, Nandi S, Bono JV, Ward DM. Revision of a dual-modular stem in patients with adverse tissue reaction. Hip Int 2020; 30:452-456. [PMID: 31390922 DOI: 10.1177/1120700019869616] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Dual-modular femoral components with exchangeable cobalt-chrome neck segments have had higher than expected failure rates due to corrosion and adverse local tissue reaction (ALTR). Complications, survival rates and early clinical outcomes of revision surgery for the treatment of corrosion and ALTR as a result of these implants are underreported. METHODS We identified 44 cases of revision THA for corrosion and ALTR resulting from the same dual modular stem. All revision procedures were performed using a modular tapered fluted titanium stem, ceramic heads and highly cross-linked polyethylene. RESULTS Complications included: dislocation, infection, reoperation, and chronic pain. Mean Harris Hip Score was 84 following revision surgery. CONCLUSIONS Patients undergoing revision surgery for ALTR related to this prosthesis should be aware of the risk of postoperative dislocation and other complications and the potential long-term risk of some chronic pain.
Collapse
Affiliation(s)
- Carl T Talmo
- Department of Orthopaedic Surgery, New England Baptist Hospital, Boston, MA, USA
| | - Claire E Robbins
- Department of Orthopaedic Surgery, New England Baptist Hospital, Boston, MA, USA
| | - Ahmed Siddiqi
- Philadelphia College of Osteopathic Medicine, PA, USA
| | - Sumon Nandi
- Department of Orthopaedic Surgery, University of Toledo, OH, USA
| | - James V Bono
- Department of Orthopaedic Surgery, New England Baptist Hospital, Boston, MA, USA
| | - Daniel M Ward
- Department of Orthopaedic Surgery, New England Baptist Hospital, Boston, MA, USA
| |
Collapse
|
32
|
Krueger DR, Guenther KP, Deml MC, Perka C. Mechanical failure of 113 uncemented modular revision femoral components. Bone Joint J 2020; 102-B:573-579. [DOI: 10.1302/0301-620x.102b5.bjj-2019-1333.r2] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Aims We evaluated a large database with mechanical failure of a single uncemented modular femoral component, used in revision hip arthroplasty, as the end point and compared them to a control group treated with the same implant. Patient- and implant-specific risk factors for implant failure were analyzed. Methods All cases of a fractured uncemented modular revision femoral component from one manufacturer until April 2017 were identified and the total number of implants sold until April 2017 was used to calculate the fracture rate. The manufacturer provided data on patient demographics, time to failure, and implant details for all notified fractured devices. Patient- and implant-specific risk factors were evaluated using a logistic regression model with multiple imputations and compared to data from a previously published reference group, where no fractures had been observed. The results of a retrieval analysis of the fractured implants, performed by the manufacturer, were available for evaluation. Results There were 113 recorded cases with fracture at the modular junction, resulting in a calculated fracture rate of 0.30% (113/37,600). The fracture rate of the implant without signs of improper use was 0.11% (41/37,600). In 79% (89/113) of cases with a failed implant, either a lateralized (high offset) neck segment, an extralong head, or the combination of both were used. Logistic regression analysis revealed male sex, high body mass index (BMI), straight component design, and small neck segments were significant risk factors for failure. Investigation of the implants (76/113) showed at least one sign of improper use in 72 cases. Conclusion Implant failure at the modular junction is associated with patient- and implant-specific risk factors as well as technical errors during implantation. Whenever possible, the use of short and lateralized neck segments should be avoided with this revision system. Implantation instructions and contraindications need to be adhered to and respected. Cite this article: Bone Joint J 2020;102-B(5):573–579.
Collapse
Affiliation(s)
- D. R. Krueger
- Center for Musculoskeletal Surgery (CMSC), Charité – Universitätsmedizin Berlin, Berlin, Germany
| | - K-P. Guenther
- Center for Orthopaedic and Trauma Surgery, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - M. C. Deml
- Department of Orthopaedic and Trauma Surgery, University of Bern, Inselspital, Bern, Switzerland
| | - C. Perka
- Center for Musculoskeletal Surgery (CMSC), Charité – Universitätsmedizin Berlin, Berlin, Germany
| |
Collapse
|
33
|
Grupp TM, Baxmann M, Jansson V, Windhagen H, Heller KD, Morlock MM, Knaebel HP. How to proceed with asymptomatic modular dual taper hip stems in the case of acetabular revision. MATERIALS 2020; 13:ma13051098. [PMID: 32121627 PMCID: PMC7084958 DOI: 10.3390/ma13051098] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Revised: 02/13/2020] [Accepted: 02/18/2020] [Indexed: 12/15/2022]
Abstract
How to proceed with a clinically asymptomatic modular Metha® Ti alloy stem with dual taper CoCr neck adapter in case of acetabular revision? To systematically answer this question the status of research and appropriate diagnostic methods in context to clinically symptomatic and asymptomatic dual taper stem-neck couplings has been evaluated based on a systematic literature review. A retrieval analysis of thirteen Metha® modular dual taper CoCr/Ti alloy hip stems has been performed and a rational decision making model as basis for a clinical recommendation was developed. From our observations we propose that in cases of acetabular revision, that for patients with a serum cobalt level of > 4 µg/L and a Co/Cr ratio > 3.6, the revision of the modular dual taper stem may be considered. Prior to acetabular revision surgery a systematic diagnostic evaluation should be executed, using specific tests such as serum metal (Co, Cr) ion analysis, plain antero-posterior and lateral radiographs and cross-sectional imaging modalities (Metal Artefact Reduction Sequence Magnetic Resonance Imaging). For an asymptomatic Metha® dual taper Ti alloy/CoCr stem-neck coupling at the stage of acetabular revision careful clinical decision making according to the proposed model should be followed and overreliance on any single examination should be avoided, considering the complete individual differential diagnosis and patient situation.
Collapse
Affiliation(s)
- Thomas M. Grupp
- Aesculap AG Research & Development, 78532 Tuttlingen, Germany;
- Department of Orthopaedic Surgery, Physical Medicine & Rehabilitation, Campus Grosshadern Ludwig Maximilians University Munich, 81377 Munich, Germany;
- Correspondence: ; Tel.: +49-7461-95-2667; Fax: +49-7461-95-382667
| | - Marc Baxmann
- Aesculap AG Research & Development, 78532 Tuttlingen, Germany;
| | - Volkmar Jansson
- Department of Orthopaedic Surgery, Physical Medicine & Rehabilitation, Campus Grosshadern Ludwig Maximilians University Munich, 81377 Munich, Germany;
| | - Henning Windhagen
- Department of Orthopaedic Surgery, Hannover Medical School, 30625 Hannover, Germany;
| | - Karl-Dieter Heller
- Department of Orthopaedic Surgery, Herzogin-Elisabeth-Hospital, 38124 Braunschweig, Germany;
| | - Michael M. Morlock
- Institute of Biomechanics, TUHH Hamburg University of Technology, 21073 Hamburg, Germany;
| | | |
Collapse
|
34
|
Desai BR, Sumarriva GE, Chimento GF. Pseudotumor recurrence in a post-revision total hip arthroplasty with stem neck modularity: A case report. World J Orthop 2020; 11:116-122. [PMID: 32190555 PMCID: PMC7063454 DOI: 10.5312/wjo.v11.i2.116] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2019] [Revised: 09/19/2019] [Accepted: 11/30/2019] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND This unique presentation of hip swelling is only the seventh reported case of pseudotumor recurrence in a non-metal-on-metal total hip arthroplasty (THA) construct. The constellation of patient symptoms and laboratory findings contradict the expected elevated serum metal ion levels associated with the formation of pseudotumor. The presentation, lab trends, and imaging findings contribute to the growing base of knowledge surrounding the effects of corrosion in arthroplasty constructs with stem-neck modularity.
CASE SUMMARY A 74-year-old man status post primary THA presented with left hip swelling and elevated serum metal ions five years after implantation of a modular stem-neck prosthesis. The swelling was diagnosed as pseudotumor based on laboratory trends and imaging findings and was treated with revision arthroplasty that completely resolved the initial hip swelling. The patient presented with recurrent hip swelling and recurrent pseudotumor findings on imaging in the same hip four months later. Non-operative management with ultrasound-guided hip aspiration resulted in symptom relief and resolution of the recurrent swelling. After one year of follow-up, the patient had no further recurrences of hip swelling.
CONCLUSION This case of post-revision pseudotumor recurrence elucidates attributable patient, surgical, and implant factors with a discussion of diagnostics, management, and prognosis for patients with pseudotumor in non-metal-on-metal arthroplasty constructs.
Collapse
Affiliation(s)
- Bhumit R Desai
- The University of Queensland School of Medicine, Ochsner Clinical School, New Orleans, LA 70121, United States
| | - Gonzalo E Sumarriva
- Department of Orthopaedics, Ochsner Clinic Foundation, New Orleans, LA 70121, United States
| | - George F Chimento
- Department of Orthopaedics, Ochsner Clinic Foundation, New Orleans, LA 70121, United States
| |
Collapse
|
35
|
Mertl P, Dehl M. Femoral stem modularity. Orthop Traumatol Surg Res 2020; 106:S35-S42. [PMID: 31624033 DOI: 10.1016/j.otsr.2019.05.019] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/26/2019] [Revised: 05/08/2019] [Accepted: 05/13/2019] [Indexed: 02/02/2023]
Abstract
Femoral stem modularity in hip replacement was first developed to connect a ceramic head to the stem, then extended to metal heads using the Morse taper principle. Is it a good thing, or a necessary evil? It contributes to improving lower limb length and lateralization setting, at the cost of fairly rare complications such as dissociation and fretting corrosion, which can exceptionally lead to ARMD (Adverse Reaction to Metal Debris). Modular necks were later recommended, with a double Morse taper: cylindrical for the head junction, and more or less flattened for the stem. Is this one modularity too far? Dual modularity in theory perfectly reproduces the biomechanical parameters of the hip, but is unfortunately associated with fractures and severe corrosion, leading to ARMD and pseudotumor, especially in Cr-Co necks. Moreover, it provides no functional advantage, and no longer has a role outside dysplasia and other femoral deformities. Metaphyseal-diaphyseal modularity is not widespread in primary implants, and is it really necessary? Only one model has been widely studied: S-Rom™ (Depuy®). It features a metaphyseal sleeve adapting to the anatomy of the proximal femur, with a stem fitted via an inverse Morse taper. Its only interest is in case of congenital dislocation; like all metal connections, it incurs a risk of fracture and corrosion. On the other hand, modularity is widely employed in revision implants. Does it really help these procedures? The connection between a proximal femoral component of variable geometry and a diaphyseal stem with press-fit distal fixation provides a real solution to problems of length, lateralization and anteversion. Early models encountered high rates of fracture, but current implants and rigorous surgical technique have reduced this risk. Corrosion is a less serious problem, as the Morse taper undergoes only axial stress, without the friction undergone by other models subject to varus stress.
Collapse
Affiliation(s)
- Patrice Mertl
- Service d'orthopédie-traumatologie, CHU d'Amiens, Site Sud, 80054 Amiens Cedex, France.
| | - Massinissa Dehl
- Service d'orthopédie-traumatologie, CHU d'Amiens, Site Sud, 80054 Amiens Cedex, France
| |
Collapse
|
36
|
K.N. C, Zuber M, Bhat N. S, Shenoy B. S, R. Kini C. Static structural analysis of different stem designs used in total hip arthroplasty using finite element method. Heliyon 2019; 5:e01767. [PMID: 31245635 PMCID: PMC6581841 DOI: 10.1016/j.heliyon.2019.e01767] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Revised: 04/09/2019] [Accepted: 05/15/2019] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND The Hip joint is the primary joint which gives stability to the human body. The wear and tear associated with age and other factors, require these joints to be replaced by implants using hip arthroplasty surgeries. Cobalt chromium alloy (CoCr), titanium alloy, stainless steel are some of the most common hip joint materials used for hip implants. The design requirement for hip joint implants are very stringent to avoid revision joint surgeries due to aseptic loosening. There are various choices in shapes and materials used for stem and acetabular designs. This makes it more difficult to make an informed decision on the type of design and material that can be used for hip implants. METHODS Circular, Oval, ellipse and trapezoidal designs with three individual cross sections (defined as profile 1, profile 2 and profile 3) are considered for the study. All models are modeled using CATIA V-6. Static structural analysis is performed using ANSYS R-19 to arrive at the best possible design and material combination for stem and acetabular cup. RESULTS It was found that, profile 2 of all the four designs has the lowest possible deformation and von Mises stress when compared to profile 1 and profile 2. In general, profile 2 with trapezoidal stem has best outcomes in terms of its mechanical properties. Besides, stem designed with material CoCr and its associated acetabular cup with CoC (ceramic on ceramic) material can produce an implant having better properties and longer durability. CONCLUSIONS CoCr was found to be the preferred choice of material for stem design. It was also observed that, irrespective of material considered for the analysis profile 2 with trapezoidal stem showcased lesser deformation and von Mises stress over the other eleven models. For analysis involving acetabular cups, CoC implants exhibited better mechanical properties over the conventional CoPE (Ceramic on polyethylene) materials such as Ultra-high molecular weight polyethylene (UHMWPE). It is inferred from the findings of this study that, the profile 2 with trapezoidal stem design made of CoCr material and acetabular cup made of CoC material is best suited for hip joint implants.
Collapse
Affiliation(s)
- Chethan K.N.
- Department of Aeronautical and Automobile Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, 576104, India
| | - Mohammad Zuber
- Department of Aeronautical and Automobile Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, 576104, India
| | - Shyamasunder Bhat N.
- Department of Orthopedics, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, 576104, India
| | - Satish Shenoy B.
- Department of Aeronautical and Automobile Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, 576104, India
| | - Chandrakant R. Kini
- Department of Aeronautical and Automobile Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, 576104, India
| |
Collapse
|
37
|
Aboltins CA, Antoci V, Bhattacharyya S, Cross M, Ducheyne P, Freiberg AA, Hailer N, Kay P, Ketonis C, Klement MR, Köse N, Lee M, Mitchell P, Nandi S, Palacio JC, Perry K, Prieto H, Shahi A, Trebše R, Turner D, Wu CT, Yazdi H. Hip and Knee Section, Prevention, Prosthesis Factors: Proceedings of International Consensus on Orthopedic Infections. J Arthroplasty 2019; 34:S309-S320. [PMID: 30348551 DOI: 10.1016/j.arth.2018.09.016] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
|
38
|
Milimonfared R, Oskouei RH, Taylor M, Solomon LB. An intelligent system for image-based rating of corrosion severity at stem taper of retrieved hip replacement implants. Med Eng Phys 2018; 61:13-24. [DOI: 10.1016/j.medengphy.2018.08.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2017] [Revised: 07/27/2018] [Accepted: 08/05/2018] [Indexed: 11/29/2022]
|
39
|
Park CW, Lim SJ, Park YS. Modular Stems: Advantages and Current Role in Primary Total Hip Arthroplasty. Hip Pelvis 2018; 30:147-155. [PMID: 30202748 PMCID: PMC6123508 DOI: 10.5371/hp.2018.30.3.147] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2018] [Accepted: 07/18/2018] [Indexed: 01/02/2023] Open
Abstract
Using modular femoral stems in total hip arthroplasty enables surgeons to make fine adjustments to individual joints and offers intraoperative flexibility. The concept of modularity has been developed in numerous shapes, resulting in a vast range of options. Among them, the greatest achievement has been made for prostheses with modular proximal sleeves. The use of these implants has resulted in excellent mid- to long-term results in a number of cases. Although the use of tapered stems with a broaching technique is gaining popularity in straightforward primary surgeries, modular femoral implants are still associated with a number of potential challenges (e.g., developmental dysplasia of the hip, infection sequelae, and skeletal dysplasia). Based on published results, it is advisable to consider it as an option for complicated cases where the proximal femur is severely deformed.
Collapse
Affiliation(s)
- Chan-Woo Park
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Seung-Jae Lim
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Youn-Soo Park
- Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| |
Collapse
|
40
|
Farhoudi H, Fallahnezhad K, Oskouei RH, Taylor M. A finite element study on the mechanical response of the head-neck interface of hip implants under realistic forces and moments of daily activities: Part 1, level walking. J Mech Behav Biomed Mater 2017; 75:470-476. [DOI: 10.1016/j.jmbbm.2017.08.012] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2017] [Revised: 08/04/2017] [Accepted: 08/08/2017] [Indexed: 10/19/2022]
|
41
|
Pelayo-de-Tomás JM, Rodrigo-Pérez JL, Novoa-Parra CD, Lizaur-Utrilla A, Morales-Suárez-Varela M, Blas-Dobón JA. Cementless modular neck stems: are they a safe option in primary total hip arthroplasty? EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2017; 28:463-469. [PMID: 29082427 DOI: 10.1007/s00590-017-2071-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2017] [Accepted: 10/14/2017] [Indexed: 01/10/2023]
Abstract
PURPOSE The objective was to assess aseptic complications and functional outcome using a primary total hip arthroplasty with modular neck. METHODS Prospective cohort of 317 consecutive patients. The mean age was 61.1 (range, 41-84) years. The H-Max-M model (Lima, Italy) system was used in all patients. The functional assessment was made by the Harris Hip Score, Short Form-36 (SF-36), Western Ontario and McMaster Universities Osteoarthritis Index and visual analogue scale for pain. Radiological outcomes were also assessed, and adverse events and complications were noted. RESULTS The mean follow-up was 6.1 (range, 2-8) years. Functional outcome significantly improved in most patients. There were 3 deep infections (0.9%) and 17 aseptic complications (5.3%) including 1 intraoperative acetabular fracture, 3 later periprosthetic femoral fractures, 1 broken ceramic insert, 1 acetabular loosening, 3 femoral loosening and 1 broken titanium modular neck in a obese patient. No pseudotumors or elevated serum levels of metal ions were found among the patients with radiolucent lines or aseptic loosening. CONCLUSIONS The findings in the present study showed that the H-MAX-M stem provided satisfactory functional outcome in most patients with a low rate of complications attributable to the modular neck design. We consider that using this novel modular neck-stem coupling design can be an alternative to the conventional monoblock stems in patients without overweight.
Collapse
Affiliation(s)
- José M Pelayo-de-Tomás
- Department of Orthopaedic Surgery, Doctor Peset University Hospital, Av Gaspar Aguilar, 90, 46017, Valencia, Spain
| | - José L Rodrigo-Pérez
- Department of Orthopaedic Surgery, Doctor Peset University Hospital, Av Gaspar Aguilar, 90, 46017, Valencia, Spain
| | - Carlos D Novoa-Parra
- Department of Orthopaedic Surgery, Doctor Peset University Hospital, Av Gaspar Aguilar, 90, 46017, Valencia, Spain.
| | | | - María Morales-Suárez-Varela
- Unit of Public Health and Environmental Care, Department of Preventive Medicine, University of Valencia, Valencia, Spain
- CIBER of Epidemiology and Public Health (CIBERESP), Madrid, Spain
| | - José Antonio Blas-Dobón
- Department of Orthopaedic Surgery, Doctor Peset University Hospital, Av Gaspar Aguilar, 90, 46017, Valencia, Spain
| |
Collapse
|
42
|
Whitehouse MR. Head-stem trunnion dissociation due to corrosion in total hip arthroplasty. ANNALS OF TRANSLATIONAL MEDICINE 2017; 5:363. [PMID: 28936457 DOI: 10.21037/atm.2017.06.42] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Michael R Whitehouse
- Musculoskeletal Research Unit, School of Clinical Sciences, Southmead Hospital, Bristol BS10 5NB, UK.,Avon Orthopaedic Centre, Southmead Hospital, North Bristol NHS Trust, Bristol BS10 5NB, UK
| |
Collapse
|
43
|
Affiliation(s)
- Mitchell C Weiser
- 1Department of Orthopaedic Surgery, New York University Langone Medical Center, Hospital for Joint Diseases, and Insall Scott Kelly Institute for Orthopaedics and Sports Medicine, New York, NY 2Department of Orthopedics & Rehabilitation, University of Miami, Coral Gables, Florida 3Department of Mechanical and Materials Engineering and Department of Physical Therapy, Florida International University, Coral Gables, Florida
| | | |
Collapse
|
44
|
Mikkelsen RT, Fløjstrup M, Klem N, Tellefsen RA, Lund C, Kjærsgaard-Andersen P, Skjødt T, Varnum C. Modular Neck vs Nonmodular Femoral Stems in Total Hip Arthroplasty-Clinical Outcome, Metal Ion Levels, and Radiologic Findings. J Arthroplasty 2017; 32:2774-2778. [PMID: 28457759 DOI: 10.1016/j.arth.2017.03.072] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2017] [Revised: 03/17/2017] [Accepted: 03/30/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Modular neck femoral stem (MNFS) for total hip arthroplasty (THA) was introduced to optimize the outcome, but created concerns about pain, elevated blood metal ion levels, and adverse reaction to metal debris such as pseudotumors (PTs), related to corrosion between femoral neck and stem. We compared these outcomes in patients with MNFS or nonmodular femoral stem (NFS) THA. METHODS Thirty-three patients with unilateral MNFS THA were compared with 30 patients with unilateral NFS THA. Levels of pain, serum cobalt, serum chromium were determined. Magnetic resonance imaging was performed to describe PT and fatty atrophy of muscles. RESULTS The MNFS and NFS group had a mean follow-up of 2.3 and 3.1 years, respectively. Four and 13 patients in the MNFS and NFS group had pain, respectively (P = .005). The MNFS group had higher levels of serum cobalt (P < .0001) and chromium (P = .006). PTs were present in both the MNFS (n = 15) and NFS (n = 7) groups (P = .066). PTs were related to serum cobalt (P = .04) but not to pain or serum chromium. Fatty atrophy prevalence in the piriformis and gluteal muscles were higher in patients with MNFS (P = .009 and P = .032, respectively). CONCLUSION More patients in the NFS group had pain. Serum cobalt and chromium levels were higher in the MNFS group. Prevalence of PTs was twice as high in the MNFS group, but the difference was insignificant.
Collapse
Affiliation(s)
- Rasmus T Mikkelsen
- Section for Hip and Knee Replacement, Department of Orthopaedic Surgery, Vejle Hospital, Vejle, Denmark
| | | | | | | | | | - Per Kjærsgaard-Andersen
- Section for Hip and Knee Replacement, Department of Orthopaedic Surgery, Vejle Hospital, Vejle, Denmark
| | - Thomas Skjødt
- Department of Radiology, Vejle Hospital, Vejle, Denmark
| | - Claus Varnum
- Section for Hip and Knee Replacement, Department of Orthopaedic Surgery, Vejle Hospital, Vejle, Denmark
| |
Collapse
|
45
|
Excellent mid-term results of a new polished tapered modular cemented stem: a study of 113 hip replacements with minimum 5-year follow-up. Hip Int 2017; 27:455-459. [PMID: 28222212 PMCID: PMC6380089 DOI: 10.5301/hipint.5000486] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 11/11/2016] [Indexed: 02/08/2023]
Abstract
BACKGROUND This prospective cohort study reports the medium-term clinical and radiographic results of 113 hips treated with a hybrid total hip replacement (THR) with a new cemented tapered cobalt-chrome (Co-Cr) stem with a titanium (Ti) modular neck (ProfemurXm®). METHOD Between October 2008 and December 2010 we performed 115 consecutive hybrid THR with the ProfemurXm® in 105 patients. RESULTS Survivorship of the implant (stem and modular neck) at a mean of 6.5 years (min 5-max 8) was 100% with the endpoint revision for any reason. No implant was at risk for revision or showed signs of loosening. The mean Harris Hip Score was 89/100, mean Oxford Hip Score was 43/48, mean WOMAC was 91/100. No patient had thigh pain, no patient reported squeaking. There were no dislocations in this cohort. No implant showed development of radiolucent lines (RLL), either at the stem-cement or cement-bone interface. No hip showed osteolysis or calcar resorption. The mean femoral subsidence of the stem within the cement mantel was 0.31 mm (range 0-0.6 mm) after 6.5 years. With the use of this modular stem, 93% of hips showed no measurable leg length difference after THR, and leg length could be restored within a 5-mm limit in 99% of hips. CONCLUSIONS The mid-term results of this new polished stem were excellent, without adverse effects from the use of modularity.
Collapse
|
46
|
Hanna SA, Sarraf KM, Ramachandran M, Achan P. Systematic review of the outcome of total hip arthroplasty in patients with sequelae of Legg-Calvé-Perthes disease. Arch Orthop Trauma Surg 2017; 137:1149-1154. [PMID: 28674737 DOI: 10.1007/s00402-017-2741-8] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2016] [Indexed: 11/30/2022]
Abstract
BACKGROUND Total hip arthroplasty (THA) in patients with sequelae of Legg-Calvé-Perthes disease (LCP) is technically demanding because of the disease related deformities occuring in the proximal femur and/or the multiplanar deformities secondary to corrective osteotomies in childhood. Little is known about the long-term outcome of the procedure in this challenging group of patients. METHODS We carried out a systematic review of the literature to determine the functional outcome, complications and revision rate of THA in patients with sequelae of LCP disease. Six out of 148 potential studies involving 245 hips met the inclusion criteria. The mean age was 45.7 years (19-74) and follow-up was 8.4 years (2-21). RESULTS There were 221 cementless THAs (90%), 22 hybrid THAs (9%) and 2 cemented THAs (1%). The femoral components used included 187 standard stems (76%), 43 modular stems (18%) and 15 custom-made stems (6%). The modular implants used were reamed S-Rom stems. All studies reported a significant improvement in hip function following THA. There were 16 revision THAs (7%) occurring at a mean of 7.5 years (0.4-10.3). Complications included intra-operative fracture (11%, n = 27), aseptic loosening (5%, n = 13), sciatic nerve palsy (3%, n = 7) and heterotopic ossification (2%, n = 4). All intra-operative fractures occurred when standard femoral stems were used. The average limb lengthening in the patients with a post-operative sciatic nerve injury was 1.9 cm. All patients with this complication had a history of previous hip surgery. CONCLUSIONS THA in patients with LCP disease results in similar functional outcome compared to patients with primary osteoarthritis; however, the revision rate at mid-term follow-up is slightly increased. Reamed modular (S-Rom) and custom femoral implants appear to be associated with a decreased risk of intra-operative fracture. Care should be taken when addressing leg length discrepancy in this group of patients due to the increased risk of sciatic nerve palsy, especially in patients with prior surgical procedures.
Collapse
Affiliation(s)
- Sammy A Hanna
- The Royal London Hospital, Barts Health NHS Trust, Whitechapel Road, London, E1 1BB, UK.
| | - Khaled M Sarraf
- St Mary's Hospital, Imperial College Healthcare NHS Trust, Praed Street, London, W2 1NY, UK
| | - Manoj Ramachandran
- The Royal London Hospital, Barts Health NHS Trust, Whitechapel Road, London, E1 1BB, UK
| | - Pramod Achan
- The Royal London Hospital, Barts Health NHS Trust, Whitechapel Road, London, E1 1BB, UK
| |
Collapse
|
47
|
Su SL, Koch CN, Nguyen TM, Burket JC, Wright TM, Westrich GH. Retrieval Analysis of Neck-Stem Coupling in Modular Hip Prostheses. J Arthroplasty 2017; 32:2301-2306. [PMID: 28262451 DOI: 10.1016/j.arth.2017.02.016] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2016] [Revised: 02/02/2017] [Accepted: 02/06/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Dual-taper modular stems have suffered from high revision rates caused by adverse local tissue reactions secondary to fretting and corrosion. We compared the fretting and corrosion behavior of a group of modular neck designs to that of a design that had been recalled for risks associated with fretting and corrosion at the modular neck junction. METHODS We previously analyzed fretting and corrosion on 60 retrieved Rejuvenate modular neck-stem implants. Here we compare those results to results from 26 retrieved implants from 7 other modular neck designs. For the 26 additional cases, histology slides of tissue collected at revision were reviewed and graded for aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL). Multivariate analyses were performed to assess differences in fretting and corrosion, adjusting for confounding factors (eg, length of implantation). RESULTS The Rejuvenate design had higher damage and corrosion scores than the other 7 designs (P < .01). Histologic samples from the recalled design were 20 times more likely to show ALVAL than samples from the other designs (P < .01). Mixed metal couples had higher fretting (P < .01) and corrosion (P = .02) scores than non-mixed metal couples. CONCLUSION Fretting and corrosion occurred on all modular neck-stem retrievals regardless of design. However, mixed metal couples suffered more corrosion than homogenous couples. This may be due to the lower modulus of the titanium alloy used for the stem, allowing for increased metal transfer and surface damage when loaded against a cobalt alloy modular neck, which in turn could account for the higher ALVAL and corrosion scores. Due to increased corrosion risk with mixed metals and increased neck fracture risk with non-mixed metal stem and necks, we suggest that clinicians avoid implantation of modular neck-stem systems.
Collapse
Affiliation(s)
- Sherwin L Su
- Adult Reconstruction and Joint Replacement Division, Hospital for Special Surgery, New York, New York
| | - Chelsea N Koch
- Department of Biomechanics, Hospital for Special Surgery, New York, New York
| | - Thu M Nguyen
- Department of Biomechanics, Hospital for Special Surgery, New York, New York
| | - Jayme C Burket
- Healthcare Research Institute, Hospital for Special Surgery, New York, New York
| | - Timothy M Wright
- Department of Biomechanics, Hospital for Special Surgery, New York, New York
| | - Geoffrey H Westrich
- Adult Reconstruction and Joint Replacement Division, Hospital for Special Surgery, New York, New York
| |
Collapse
|
48
|
Graves SE, de Steiger R, Davidson D, Donnelly W, Rainbird S, Lorimer MF, Cashman KS, Vial RJ. The use of femoral stems with exchangeable necks in primary total hip arthroplasty increases the rate of revision. Bone Joint J 2017; 99-B:766-773. [DOI: 10.1302/0301-620x.99b6.38020] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2016] [Accepted: 11/17/2016] [Indexed: 12/13/2022]
Abstract
Aims Femoral stems with exchangeable (modular) necks were introduced to offer surgeons an increased choice when determining the version, offset and length of the femoral neck during total hip arthroplasty (THA). It was hoped that this would improve outcomes and reduce complications, particularly dislocation. In 2010, the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) first reported an increased rate of revision after primary THA using femoral stems with an exchangeable neck. The aim of this study was to provide a more comprehensive up-to-date analysis of primary THA using femoral stems with exchangeable and fixed necks. Materials and Methods The data included all primary THA procedures performed for osteoarthritis (OA), reported to the AOANJRR between 01 September 1999 and 31 December 2014. There were 9289 femoral stems with an exchangeable neck and 253 165 femoral stems with a fixed neck. The characteristics of the patients and prostheses including the bearing surface and stem/neck metal combinations were examined using Cox proportional hazard ratios (HRs) and Kaplan-Meier estimates of survivorship. Results It was found that prostheses with an exchangeable neck had a higher rate of revision and this was evident regardless of the bearing surface or the size of the femoral head. Exchangeable neck prostheses with a titanium stem and a cobalt-chromium neck had a significantly higher rate of revision compared with titanium stem/titanium neck combinations (HR 1.83, 95% confidence interval 1.49 to 2.23, p < 0.001). Revisions were higher for these combinations compared with femoral stems with a fixed neck. Conclusion There appears to be little evidence to support the continued use of prostheses with an exchangeable neck in primary THA undertaken for OA. Cite this article: Bone Joint J 2017;99-B:766–73.
Collapse
Affiliation(s)
- S. E. Graves
- Australian Orthopaedic Association National
Joint Replacement Registry, South Australian Health
and Medical Research Institute, Level 4, North
Terrace, Adelaide, 5000, Australia
| | - R. de Steiger
- Australian Orthopaedic Association National
Joint Replacement Registry, South Australian Health
and Medical Research Institute, Level 4, North
Terrace, Adelaide, 5000, Australia
| | - D. Davidson
- Australian Orthopaedic Association National
Joint Replacement Registry, South Australian Health
and Medical Research Institute, Level 4, North
Terrace, Adelaide, 5000, Australia
| | - W. Donnelly
- Australian Orthopaedic Association National
Joint Replacement Registry, South Australian Health
and Medical Research Institute, Level 4, North
Terrace, Adelaide, 5000, Australia
| | - S. Rainbird
- Australian Orthopaedic Association National
Joint Replacement Registry, South Australian Health
and Medical Research Institute, Level 4, North
Terrace, Adelaide, 5000, Australia
| | - M. F. Lorimer
- South Australian Health and Medical Research
Institute, Level 4, North
Terrace, Adelaide, 5000, Australia
| | - K. S. Cashman
- South Australian Health and Medical Research
Institute, Level 4, North
Terrace, Adelaide, 5000, Australia
| | - R. J. Vial
- Australian Orthopaedic Association National
Joint Replacement Registry, South Australian Health
and Medical Research Institute I, Level 4, North
Terrace, Adelaide, 5000, Australia
| |
Collapse
|
49
|
Lee YK, Kim JT, Alkitaini AA, Kim KC, Ha YC, Koo KH. Conversion Hip Arthroplasty in Failed Fixation of Intertrochanteric Fracture: A Propensity Score Matching Study. J Arthroplasty 2017; 32:1593-1598. [PMID: 28089470 DOI: 10.1016/j.arth.2016.12.018] [Citation(s) in RCA: 46] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/16/2016] [Revised: 11/21/2016] [Accepted: 12/12/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Conversion hip arthroplasty is a salvage procedure for failed internal fixation of intertrochanteric fractures. However, the technical difficulties and perioperative morbidity of conversion arthroplasty are uncertain. METHODS We compared the type of arthroplasty (total hip arthroplasty or hemiarthroplasty), operative parameters, perioperative morbidity, 1-year mortality, implant stability, and clinical results of 33 conversion hip arthroplasties due to a failed internal fixation of intertrochanteric fracture with those of a matched control group of 33 primary hip arthroplasties due to the same fracture. Propensity score was used for the control matching of gender, age, and body mass index. RESULTS Total hip arthroplasty was more frequently performed in the conversion group (10/33) compared to the primary group (3/33) (P = .016). The operation time, perioperative blood loss, amount of transfusion, and risk of femoral fracture during the operation were increased in the conversion group. The overall 1-year mortality was 3% (1 patient) in the conversion group and 9% (3 patients) in the primary group (P = .307). At a mean of 3-year follow-up, there was no significant difference in clinical results and none of the implants were loose in both groups. CONCLUSION In patients with failed internal fixation of intertrochanteric fracture, conversion hip arthroplasty should be planned and executed, bearing in mind the increased operative morbidities corresponding to operation time, perioperative blood loss, requirement of transfusion, and intraoperative femoral fracture.
Collapse
Affiliation(s)
- Young-Kyun Lee
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Bundang-gu, Seongnam-si, Gyeonggi-do, South Korea
| | - Jung Taek Kim
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Bundang-gu, Seongnam-si, Gyeonggi-do, South Korea
| | | | - Ki-Choul Kim
- Department of Orthopaedic Surgery, Dankook University College of Medicine, Dongnam-gu, Cheonan-si, Chungcheongnam-do, South Korea
| | - Yong-Chan Ha
- Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Dongjak-gu, Seoul, South Korea
| | - Kyung-Hoi Koo
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Bundang-gu, Seongnam-si, Gyeonggi-do, South Korea
| |
Collapse
|
50
|
Sensitivity and Specificity of Metal Ion Levels in Predicting "Pseudotumors" due to Taper Corrosion in Patients With Dual Taper Modular Total Hip Arthroplasty. J Arthroplasty 2017; 32:996-1000. [PMID: 27776907 DOI: 10.1016/j.arth.2016.08.040] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2016] [Revised: 08/28/2016] [Accepted: 08/29/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Currently, no serum metal ion threshold exists to identify adverse tissue reactions in total hip arthroplasty (THA) patients with taper corrosion. Our study aims to investigate the sensitivity and specificity of serum metal ions in detecting taper corrosion related pseudotumors in patients with dual taper modular THA. METHODS A total of 148 patients with dual taper modular THA were investigated: (1) 90 patients with pseudotumors detected with metal artifact reduction sequence-magnetic resonance imaging (MARS-MRI) and (2) 58 patients without pseudotumors on MARS-MRI. Receiver operating characteristic curves were constructed to determine the sensitivity and specificity using different metal ion thresholds. The severity of intraoperative tissue damage was correlated with preoperative metal ion levels. RESULTS Pseudotumor was associated with higher cobalt (5.0 μg/L vs 3.7 μg/L, P < .01) and Co/Cr ratio (6.0 vs 3.7, P < .01). The sensitivity and specificity for cobalt level of 2.8 μg/L and Co/Cr ratio of 3.8 in detecting taper corrosion-related pseudotumors on MARS-MRI was 88% and 32% and 70% and 50%, respectively. Higher intraoperative tissue damage grades demonstrated significantly higher Co/Cr ratios (8.6 vs 3.4, P = .03). CONCLUSION Although metal ion levels alone should not be relied on as the sole parameter to determine revision surgery, cobalt level >2.8 μg/L and the Co/Cr ratio >3.8 are useful clinical diagnostic adjuncts in the systematic clinical evaluation for taper corrosion-related adverse tissue reactions in patients with dual modular taper THA.
Collapse
|