1
|
Ishida T, Tateiwa T, Takahashi Y, Nishikawa Y, Shishido T, Masaoka T, Yamamoto K. Adverse Tissue Reactions and Metal Ion Behavior After Small-Head Metasul Hip Arthroplasty: A Long-Term Follow-Up Study. Orthop Surg 2021; 14:264-273. [PMID: 34910382 PMCID: PMC8867442 DOI: 10.1111/os.13125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Revised: 05/10/2021] [Accepted: 06/03/2021] [Indexed: 11/29/2022] Open
Abstract
Objective To investigate the long‐term survivorship, incidence of adverse reactions to metal debris (ARMD), and metal ion behavior in patients who underwent small‐head Metasul metal‐on‐metal (MoM) total hip arthroplasty (THA). Methods Between February 1998 and September 2003, a retrospective study was performed on 43 consecutive patients (43 hips) who underwent unilateral cementless Metasul MoM THAs at our institution. Of them, 35 patients (nine males and 26 females) who were available for follow‐up more than 15 years after THA were enrolled in this study and underwent metal artifact reduction sequence magnetic resonance imaging (MARS‐MRI) to identify ARMD. The mean age at surgery of the patients was 59.7 years old (range, 31–83). Clinical and radiographic outcomes were evaluated retrospectively. Clinical examinations were conducted using the Harris Hip Score (HHS). Serum cobalt (Co) and chromium (Cr) ion levels and Co/Cr ratio were assessed at different postoperative periods of <5, 5–10, 11–14, and ≥15 years. Results The mean follow‐up period for the 35 patients included was 18.1 years (range, 15–22). The mean HHS significantly improved from 44.6 ± 11.3 points preoperatively to 89.4 ± 7.9 points at the final follow‐up (P < 0.0001). ARMD was found in 20% of the patients using MARS‐MRI. No signs of stem loosening were found clinically or radiographically, whereas cup loosening and ARMD were observed in three patients (9%), for whom revision THAs were performed. The Kaplan–Meier survival rates with revision for any reason as the endpoint were 90.9% at 5 years, 84.8% at 10 years, 84.8% at 15 years (95% CI, 67.1–93.6), and 70.3% at 20 years (95% CI, 43.6–87.0). The survival rates with revision for ARMD as the endpoint were 100% at 5 years, 96.6% at 10 years, 96.6% at 15 years (95% CI, 77.2–99.7), and 80.1% at 20 years (95% CI, 45.3–95.2). Serum Co ion level peaked at 5–10 years after THA, which was significantly higher than that <5 years; however, it decreased to the initial level after 15 years. In contrast, serum Cr ion level significantly increased at 5–10 years and then remained almost constant. Significant differences in Cr ion levels (1.0 vs 2.0 μg/L, P = 0.024) and Co/Cr ratio (1.3 vs 0.9, P = 0.037) were found between non‐ARMD and ARMD patients at >11 years postoperatively. Conclusion Our results suggest that increased Cr ion levels and decreased Co/Cr ratio may be signs of ARMD in patients who underwent small‐head Metasul MoM THA.
Collapse
Affiliation(s)
- Tsunehito Ishida
- Department of Orthopedic Surgery, Tokyo Medical University, Tokyo, Japan
| | - Toshiyuki Tateiwa
- Department of Orthopedic Surgery, Tokyo Medical University, Tokyo, Japan
| | - Yasuhito Takahashi
- Department of Orthopedic Surgery, Tokyo Medical University, Tokyo, Japan.,Department of Bone and Joint Biomaterial Research, Tokyo Medical University, Tokyo, Japan
| | - Yohei Nishikawa
- Department of Orthopedic Surgery, Tokyo Medical University, Tokyo, Japan
| | - Takaaki Shishido
- Department of Orthopedic Surgery, Tokyo Medical University, Tokyo, Japan
| | - Toshinori Masaoka
- Department of Orthopedic Surgery, Tokyo Medical University, Tokyo, Japan
| | - Kengo Yamamoto
- Department of Orthopedic Surgery, Tokyo Medical University, Tokyo, Japan
| |
Collapse
|
2
|
Jin SY, Jin JY, Kang JK, Yoon TR, Park KS. Minimum 15-year results of metasul 28-mm metal-on-metal total hip arthroplasty in patients younger than 50 years of age. J Orthop Surg Res 2021; 16:218. [PMID: 33766094 PMCID: PMC7992988 DOI: 10.1186/s13018-021-02352-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Accepted: 03/10/2021] [Indexed: 11/10/2022] Open
Abstract
Background Some propitious mid- and long-term studies had been reported for MoM bearings; however, most studies have addressed specific patient groups rather than younger, active patients, who probably represent the most suitable population for investigations on wear and osteolysis. The purpose of this study to evaluate the long-term results of second-generation metal-on-metal cementless total hip arthroplasty (THA) in patients aged <50 years. Methods From December 1997 to January 2004, primary THA using a metal-on-metal bearing cementless implant was performed in 63 patients (72 hips) aged <50 years. The mean follow-up duration was 18.6 (range, 15.9–22.1) years, and the mean age at initial operation was 39 (range, 22–49) years. Clinical results, complications, survivorship, osteolysis, and aseptic loosening were evaluated. Results The mean Harris hip score and Western Ontario and McMaster Universities Arthritis Index scores were improved from 57.8 (range, 28–69) points and 73.4 (range, 63–94) points preoperatively to 91.7 (range, 80–100) points and 25.5 points (range, 17–38) points, respectively, at the last follow-up. Osteolysis lesions were found in 12 hips (acetabulum, 6 and femur, 6). The notching occurred on the femoral stem neck occurred in 12 hips. The mean serum cobalt and chromium concentrations were 2.3 (range, 0.2–10.6) μg/L and 1.7 (range, 0.4–8.1) μg/L, respectively, at a mean follow-up of 12.7 years in 32 patients (50.1%). The Kaplan-Meier survivorship curve analysis with revision for any reason as the endpoint revealed that 93.1% survived at 18.6 years’ follow-up. Conclusions Second-generation metal-on-metal cementless THA was found to produce satisfactory clinical and radiographic results with a low revision rate for osteolysis and aseptic loosening in patients aged less than 50 years.
Collapse
Affiliation(s)
- Sheng-Yu Jin
- Department of Orthopedics, Center for Joint Disease, Chonnam National University Hwasun Hospital, 322, Seo Yang-Ro, Hwasun-Eup, Hwasun-Gun, Jeonnam, 519-809, Republic of Korea
| | - Jing-Yao Jin
- Department of Orthopedics, Center for Joint Disease, Chonnam National University Hwasun Hospital, 322, Seo Yang-Ro, Hwasun-Eup, Hwasun-Gun, Jeonnam, 519-809, Republic of Korea
| | - Joon-Kyoo Kang
- Department of Orthopedics, Center for Joint Disease, Chonnam National University Hwasun Hospital, 322, Seo Yang-Ro, Hwasun-Eup, Hwasun-Gun, Jeonnam, 519-809, Republic of Korea
| | - Taek-Rim Yoon
- Department of Orthopedics, Center for Joint Disease, Chonnam National University Hwasun Hospital, 322, Seo Yang-Ro, Hwasun-Eup, Hwasun-Gun, Jeonnam, 519-809, Republic of Korea
| | - Kyung-Soon Park
- Department of Orthopedics, Center for Joint Disease, Chonnam National University Hwasun Hospital, 322, Seo Yang-Ro, Hwasun-Eup, Hwasun-Gun, Jeonnam, 519-809, Republic of Korea.
| |
Collapse
|
3
|
Reiner T, Klotz MC, Seelmann K, Hertzsch F, Innmann MM, Streit MR, Nees TA, Moradi B, Merle C, Kretzer JP, Gotterbarm T. Long-Term Results of a Second-Generation, Small-Diameter, Metal-On-Metal Bearing in Primary Total Hip Arthroplasty at 14-year Follow-Up. MATERIALS 2020; 13:ma13030557. [PMID: 31991553 PMCID: PMC7040657 DOI: 10.3390/ma13030557] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Revised: 01/13/2020] [Accepted: 01/20/2020] [Indexed: 12/12/2022]
Abstract
(1) Background: The objective of the present study was to review the clinical and radiological results of a small-head, MoM bearing in primary THA and to determine blood metal ion levels at long-term follow-up. (2) Methods: We retrospectively evaluated the clinical and radiological results of 284 small-diameter, MoM 28-mm Metasul THA at a mean follow-up of 14.5 years, and measured blood metal ion concentrations in 174 of these patients. (3) Results: After 14 years, survival free for revision due to any reason was 94%. Proximal femoral osteolysis was seen in 23% of hips, and MRI demonstrated ARMD in 27 of the 66 investigated hips (41%). Mean cobalt, chromium, and titanium ion concentrations were 0.82 µg/L (range 0.22-4.45), 1.51 µg/L (0.04-22.69), and 2.68 µg/L (0.26-19.56) in patients with unilateral THA, and 2.59 µg/L (0.43-24.75), 2.50 µg/L (0.26-16.75), and 3.76 µg/L (0.67-19.77), respectively in patients with bilateral THA. Twenty-nine percent of patients showed cobalt or chromium ion levels > 2 µg/L. (4) Conclusions: Despite good clinical long-term results, increased blood metal ion levels (cobalt or chromium > 2 µg/L) were found in approximately one-third of asymptomatic patients, and proximal femoral osteolysis and ARMD were frequently seen in this cohort. Blood metal ion analysis appears helpful in the long-term follow-up of these patients in order to identify individuals at risk. In accordance with contemporary consensus statements, symptomatic patients with elevated metal ion levels and/or progressive osteolysis should be considered for additional CT or MARS MRI to determine the extent of soft tissue affection prior to revision surgery. Further studies are necessary to investigate the clinical relevance of ARMD in asymptomatic patients with small-head, MoM THA.
Collapse
Affiliation(s)
- Tobias Reiner
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.C.K.); (K.S.); (F.H.); (M.M.I.); (M.R.S.); (T.A.N.); (B.M.); (C.M.); (T.G.)
- Correspondence: ; Tel.: +49-6221-5634803; Fax: +49-6221-5626360
| | - Matthias C. Klotz
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.C.K.); (K.S.); (F.H.); (M.M.I.); (M.R.S.); (T.A.N.); (B.M.); (C.M.); (T.G.)
| | - Kirsten Seelmann
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.C.K.); (K.S.); (F.H.); (M.M.I.); (M.R.S.); (T.A.N.); (B.M.); (C.M.); (T.G.)
| | - Fabian Hertzsch
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.C.K.); (K.S.); (F.H.); (M.M.I.); (M.R.S.); (T.A.N.); (B.M.); (C.M.); (T.G.)
| | - Moritz M. Innmann
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.C.K.); (K.S.); (F.H.); (M.M.I.); (M.R.S.); (T.A.N.); (B.M.); (C.M.); (T.G.)
| | - Marcus R. Streit
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.C.K.); (K.S.); (F.H.); (M.M.I.); (M.R.S.); (T.A.N.); (B.M.); (C.M.); (T.G.)
| | - Timo A. Nees
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.C.K.); (K.S.); (F.H.); (M.M.I.); (M.R.S.); (T.A.N.); (B.M.); (C.M.); (T.G.)
| | - Babak Moradi
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.C.K.); (K.S.); (F.H.); (M.M.I.); (M.R.S.); (T.A.N.); (B.M.); (C.M.); (T.G.)
| | - Christian Merle
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.C.K.); (K.S.); (F.H.); (M.M.I.); (M.R.S.); (T.A.N.); (B.M.); (C.M.); (T.G.)
| | - Jan Philippe Kretzer
- Laboratory of Biomechanics and Implant Research, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, 69118 Heidelberg, Germany;
| | - Tobias Gotterbarm
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.C.K.); (K.S.); (F.H.); (M.M.I.); (M.R.S.); (T.A.N.); (B.M.); (C.M.); (T.G.)
- Department of Orthopedics, Kepler University Hospital, Krankenhausstr. 7a, 4020 Linz, Austria
| |
Collapse
|
4
|
Tuning the tribofilm nanostructures of polymer-on-metal joint replacements for simultaneously enhancing anti-wear performance and corrosion resistance. Acta Biomater 2019; 87:285-295. [PMID: 30682423 DOI: 10.1016/j.actbio.2019.01.038] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2018] [Revised: 12/14/2018] [Accepted: 01/17/2019] [Indexed: 02/08/2023]
Abstract
Total joint replacement is currently the most successful clinical treatment for improving the life quality of individuals afflicted with end-stage osteoarthritis of knee or hip joints. However, release of wear and corrosion products from the prostheses is a critical issue causing adverse physiological responses of local issues. β-SiC nanoparticles were dispersed into polyetheretherketone (PEEK) materials and their role in tribocorrosion performance of PEEK-steel joints exposed to simulated body fluid was investigated. It is demonstrated that β-SiC nanoparticles increase greatly the wear resistance of the PEEK materials, and meanwhile mitigate significantly corrosion of the steel counterpart. It is revealed that tribochemical reactions of β-SiC nanoparticles promoted formation of a robust tribofilm having complex structures providing protection and shielding effects. The present work proposes a strategy for developing high-performance polymer-on-metal joint replacement materials of enhanced lifespan and biocompatibility via tuning interface nanostructures. STATEMENT OF SIGNIFICANCE: Adverse tissue responses to metal wear and corrosion products from metal base implants remain a challenge to surgeons and patients. We demonstrated that leaching of metal ions and release of metallic debris are well decreased via tuning interface nanostructures of metal-polymer joint bearings by dispersing β-SiC nanoparticles into polyetheretherketone (PEEK). It is identified that the addition of β-SiC greatly improves the tribological performances of the PEEK materials and mitigated corrosion of the steel. Tribo-chemistry reactions of SiC induce the formation of complex structures which provide protection and shielding effects. Nanostructures of the tribofilm were also comprehensively investigated. These novel findings proposed a potential route for designing high performance metal-polymer joint replacement materials.
Collapse
|
5
|
Moon JK, Kim Y, Hwang KT, Yang JH, Ryu JA, Kim YH. Prevalence and natural course of pseudotumours after small-head metal-on-metal total hip arthroplasty: a minimum 18-year follow-up study of a previous report. Bone Joint J 2019; 101-B:317-324. [PMID: 30813798 DOI: 10.1302/0301-620x.101b3.bjj-2018-1054.r1] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS The present study investigated the five-year interval changes in pseudotumours and measured serum metal ions at long-term follow-up of a previous report of 28 mm diameter metal-on-metal (MoM) total hip arthroplasty (THA). PATIENTS AND METHODS A total of 72 patients (mean age 46.6 years (37 to 55); 43 men, 29 women; 91 hips) who underwent cementless primary MoM THA with a 28 mm modular head were included. The mean follow-up duration was 20.3 years (18 to 24). All patients had CT scans at a mean 15.1 years (13 to 19) after the index operation and subsequent follow-up at a mean of 20.2 years (18 to 24). Pseudotumour volume, type of mass, and new-onset pseudotumours were evaluated using CT scanning. Clinical outcomes were assessed by Harris Hip Score (HHS) and the presence of groin pain. Serum metal ion (cobalt (Co) and chromium (Cr)) levels were measured at the latest follow-up. RESULTS At final follow-up, pseudotumours were observed in 26/91 hips (28.6%). There was an increase in volume of the pseudotumour in four hips (15.4%), no change in volume in 21 hips (80.8%), and a decrease in volume in one hip (3.8%). There were no new-onset pseudotumours. There was no significant difference in HHS between patients with and without pseudotumours. At final follow-up, mean serum Co ion levels and median Co:Cr ratios were significantly greater in patients with pseudotumours, but the serum Cr ion levels were not significantly different. CONCLUSION At a mean 20 years of follow-up, pseudotumours were observed in 26/91 hips (28.6%) with no new-onset pseudotumours during subsequent follow-up. Most pseudotumours in small-head MoM THA were static in volume and asymptomatic with normal serum metal ion levels. Cite this article: Bone Joint J 2019;101-B:317-324.
Collapse
Affiliation(s)
- J-K Moon
- Department of Orthopedic Surgery, Hanyang University Guri Hospital, Guri, South Korea
| | - Y Kim
- Department of Orthopedic Surgery, Hanyang University Hospital, Seoul, South Korea
| | - K-T Hwang
- Department of Orthopedic Surgery, Hanyang University Hospital, Seoul, South Korea
| | - J-H Yang
- Department of Orthopedic Surgery, Hanyang University Guri Hospital, Guri, South Korea
| | - J-A Ryu
- Department of Radiology, Hanyang University Guri Hospital, Guri, South Korea
| | - Y-H Kim
- Department of Orthopedic Surgery, Hanyang University Guri Hospital, Guri, South Korea
| |
Collapse
|
6
|
Reiner T, Do TD, Klotz MC, Hertzsch F, Seelmann K, Gaida MM, Weber MA, Gotterbarm T. MRI Findings in Patients After Small-Head Metal-on-Metal Total Hip Arthroplasty with a Minimum Follow-up of 10 Years. J Bone Joint Surg Am 2017; 99:1540-1546. [PMID: 28926383 DOI: 10.2106/jbjs.16.01021] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Concern has been raised about the late onset of adverse reactions to metal debris (ARMD) in patients with a small-head metal-on-metal total hip replacement. The aims of this study were to assess the frequency and characteristic appearance of ARMD in patients with a small-head (28-mm) metal-on-metal total hip replacement and elevated blood ion levels (>1 μg/L) after a minimum follow-up of 10 years and to analyze the possible risk factors associated with the prevalence of these lesions. METHODS In the present study, we used metal artifact reduction sequence magnetic resonance imaging (MARS MRI) to investigate the cases of 53 patients (66 hips) with a small-head (28-mm) metal-on-metal total hip replacement and elevated blood ion levels at a mean follow-up interval of 15.5 years (range, 10.6 to 19.3 years). Whole blood metal ion levels (cobalt and chromium), clinical outcome scores (Harris hip score), and radiographs were obtained for each patient. Tissue samples from patients who had revision surgery were histologically examined. RESULTS MARS MRI revealed ARMD in 27 hips (41%). Most hips with ARMD (67%) were asymptomatic. ARMD were generally small, with a median lesion size of 2.3 cm (range, 0.3 to 71.4 cm) and predominantly cystic in nature. Multivariate regression analysis revealed positive correlation between cobalt ion levels and the presence of ARMD. In this case series, the risk for the development of ARMD was 2.87 times higher for every 1 μg/L increase of blood cobalt ion concentration (95% confidence interval, 1.01 to 8.17; p = 0.048). CONCLUSIONS In this case series, ARMD were seen in 41% of the hips following small-head metal-on-metal total hip arthroplasty at long-term follow-up, and most patients with ARMD were asymptomatic. Blood cobalt ion levels could be identified as a risk factor for ARMD. However, ARMD also occurred in patients with low metal ion levels. Further studies are necessary to investigate the role of ARMD in asymptomatic patients with this bearing type. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Tobias Reiner
- 1Center for Orthopedics, Trauma Surgery and Spinal Cord Injury (T.R., M.C.K., F.H., K.S., and T.G.), and Department of Diagnostic and Interventional Radiology (T.D.D. and M.-A.W.), Heidelberg University Hospital, Heidelberg, Germany 2Institute for Pathology, University of Heidelberg, Heidelberg, Germany
| | | | | | | | | | | | | | | |
Collapse
|
7
|
Haddad FS. A positive end to 2016. Bone Joint J 2016; 98-B:1569-1570. [PMID: 27909115 DOI: 10.1302/0301-620x.98b12.38083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2016] [Accepted: 10/31/2016] [Indexed: 11/05/2022]
Affiliation(s)
- F S Haddad
- The Bone & Joint Journal, 22 Buckingham Street, London, WC2N 6ET and NIHR University College London Hospitals Biomedical Research Centre, UK
| |
Collapse
|
8
|
Delaunay CP, Putman S, Puliéro B, Bégin M, Migaud H, Bonnomet F. Cementless Total Hip Arthroplasty With Metasul Bearings Provides Good Results in Active Young Patients: A Concise Followup. Clin Orthop Relat Res 2016; 474:2126-33. [PMID: 27278679 PMCID: PMC5014817 DOI: 10.1007/s11999-016-4920-2] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND A primary concern of younger, more active patients who have undergone total hip arthroplasty (THA) is the longevity of the implant. Cementless fixation and hard-on-hard bearings are recognized as options to enhance THA durability. Earlier, we published a series of 83 cementless primary THAs using 28-mm metal-on-metal (MoM) bearings in patients aged 50 years or younger; here we provide concise followup on that same group after an additional 8-year survey period. QUESTIONS/PURPOSES (1) What is the long-term survivorship of cementless primary THA using 28-mm MoM bearings in patients aged 50 years or younger? (2) What are the clinical and radiographic results of cementless THA in this active patient population? (3) Can any of the observed implant failures or adverse events be attributed to the metallic nature of the bearing couple? METHODS We retrospectively reviewed 83 cementless THAs performed in three institutions over a decade (1995-2004) in 68 patients with 28-mm MoM articulation. All patients (15 bilateral) had a median age of 42 years (range, 24-50 years) at the time of the index procedure and 56 of them (82% [70 hips]) had activity level graded Devane 4 or 5 before significant hip pain. A 28-mm Metasul™ articulation was used with an Alloclassic-SL™ cementless stem in all cases paired with three different cementless titanium acetabular components (one threaded and two press-fit cups) from the same manufacturer. Survivorship analysis was calculated according to Dobbs life table, patient clinical results were evaluated with use of the Postel-Merle d'Aubigné scoring system, radiographic analysis was performed by independent observers, and cobalt level was determined in whole blood. RESULTS The 15-year survivorship (33 hips at risk) for revision for any reasons (four hips) and for aseptic loosening (one hip) was 96% (95% confidence interval [CI], 81%-99%) and 99% (95% CI, 85%-99.9%), respectively. The median Merle d'Aubigné-Postel score remained stable at 17 points (range, 10-18). Thus far, we have not observed pseudotumors or other adverse reactions to metallic debris. Eight hips have undergone reoperation: trochanteric suture removal (one), psoas tendon impingement (two), and five revisions for periprosthetic fracture (one), late infection (two), acetabular osteolysis (one, as a result of polyethylene backside wear), and one hydroxyapatite-coated cup for aseptic loosening. None of the complications, failures, or revisions observed so far could directly be related to the metallic nature of the 28-mm Metasul bearings used in this selected group of patients. CONCLUSIONS The current survey at 13-year median followup has not yet indicated any long-term deleterious effects related to dissemination of metallic ions. Two senior authors continue to use 28- or 32-mm Metasul™ bearings with cementless THA components in young and active patient populations. Longer followup with a more sophisticated imaging study is necessary to confirm this so far positive report. LEVEL OF EVIDENCE Level IV, therapeutic study.
Collapse
Affiliation(s)
- Christian P Delaunay
- Department of Orthopaedic Surgery, Clinique de l'Yvette, 67-71 route de Corbeil, 91160, Longjumeau, France.
| | | | | | - Matthieu Bégin
- Department of Orthopaedic Surgery, Clinique de l'Yvette, 67-71 route de Corbeil, 91160, Longjumeau, France
| | | | | |
Collapse
|
9
|
Vasconcelos DM, Santos SG, Lamghari M, Barbosa MA. The two faces of metal ions: From implants rejection to tissue repair/regeneration. Biomaterials 2016; 84:262-275. [DOI: 10.1016/j.biomaterials.2016.01.046] [Citation(s) in RCA: 64] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2015] [Revised: 01/20/2016] [Accepted: 01/21/2016] [Indexed: 12/20/2022]
|
10
|
Lombardi AV, Berend KR, Adams JB, Satterwhite KL. Adverse Reactions to Metal on Metal Are Not Exclusive to Large Heads in Total Hip Arthroplasty. Clin Orthop Relat Res 2016; 474:432-40. [PMID: 26497881 PMCID: PMC4709305 DOI: 10.1007/s11999-015-4539-8] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND There is some suggestion that smaller diameter heads in metal-on-metal total hip arthroplasty (MoM THA) may be less prone to the adverse reactions to metal debris (ARMD) seen with large-diameter heads. QUESTIONS/PURPOSES We reviewed our population of patients with small head (≤ 32 mm) MoM THA to determine (1) the frequency of ARMD; (2) potential risk factors for ARMD in this population; and (3) the etiology of revision and Kaplan-Meier survivorship with revision for all causes. METHODS Small-diameter head MoM devices were used in 9% (347 of 3753) of primary THAs during the study period (January 1996 to March 2005). We generally used these implants in younger, more active, higher-demand patients. Three hundred hips (258 patients) had MoM THA using a titanium modular acetabular component with a cobalt-chromium tapered insert and were available for review with minimum 2-year followup (mean, 10 years; range, 2-19 years). Complete followup was available in 86% of hips (300 of 347). Clinical records and radiographs were reviewed to determine the frequency and etiology of revision. Kaplan-Meier survivorship analysis was performed. RESULTS ARMD frequency was 5% (14 of 300 hips) and represented 70% (14 of 20) of revisions performed. Using multivariate analysis, no variable tested, including height, weight, body mass index, age, cup diameter, cup angle, use of screws, stem diameter, stem type, head diameter, preoperative clinical score, diagnosis, activity level, or sex, was significant as a risk factor for revision. Twenty hips have been revised: two for infection, four for aseptic loosening, and 14 for ARMD. Kaplan-Meier analysis revealed survival free of component revision for all causes was 95% at 10 years (95% confidence interval [CI], 91%-97%), 92% at 15 years (95% CI, 87%-95%), and 72% at 19 years (95% CI, 43%-90%), and survival free of component revision for aseptic causes was 96% at 10 years (95% CI, 92%-98%), 92% at 15 years (95% CI, 88%-95%), and 73% at 19 years (95% CI, 43%-90%). CONCLUSIONS The late onset and devastating nature of metal-related failures is concerning with this small-diameter MoM device. Although the liner is modular, it cannot be exchanged and full acetabular revision is required. Patients with all MoM THA devices should be encouraged to return for clinical and radiographic followup, and clinicians should maintain a low threshold to perform a systematic evaluation. Symptomatic patients should undergo thorough investigation and vigilant observation for ARMD. LEVEL OF EVIDENCE Level IV, therapeutic study.
Collapse
Affiliation(s)
- Adolph V. Lombardi
- Joint Implant Surgeons, Inc, New Albany, OH USA ,grid.412332.50000000115450811The Ohio State University Wexner Medical Center, Columbus, OH USA ,grid.416149.fMount Carmel Health System, New Albany, OH USA ,Joint Implant Surgeons, Inc, 7277 Smith’s Mill Road, Suite 200, New Albany, OH 43054 USA
| | - Keith R. Berend
- Joint Implant Surgeons, Inc, New Albany, OH USA ,grid.412332.50000000115450811The Ohio State University Wexner Medical Center, Columbus, OH USA ,grid.416149.fMount Carmel Health System, New Albany, OH USA
| | | | | |
Collapse
|
11
|
Singh G, Nuechtern JV, Meyer H, Fiedler GM, Awiszus F, Junk-Jantsch S, Bruegel M, Pflueger G, Lohmann CH. Particle characterisation and cytokine expression in failed small-diameter metal-on-metal total hip arthroplasties. Bone Joint J 2015; 97-B:917-23. [DOI: 10.1302/0301-620x.97b7.35163] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
The peri-prosthetic tissue response to wear debris is complex and influenced by various factors including the size, area and number of particles. We hypothesised that the ‘biologically active area’ of all metal wear particles may predict the type of peri-prosthetic tissue response. Peri-prosthetic tissue was sampled from 21 patients undergoing revision of a small diameter metal-on-metal (MoM) total hip arthroplasty (THA) for aseptic loosening. An enzymatic protocol was used for tissue digestion and scanning electron microscope was used to characterise particles. Equivalent circle diameters and particle areas were calculated. Histomorphometric analyses were performed on all tissue specimens. Aspirates of synovial fluid were collected for analysis of the cytokine profile analysis, and compared with a control group of patients undergoing primary THA (n = 11) and revision of a failed ceramic-on-polyethylene arthroplasty (n = 6). The overall distribution of the size and area of the particles in both lymphocyte and non-lymphocyte-dominated responses were similar; however, the subgroup with lymphocyte-dominated peri-prosthetic tissue responses had a significantly larger total number of particles. 14 cytokines (interleukin (IL)-1ß, IL-2, IL-4, IL-5, IL-6, IL-10, IL-13, IL-17, interferon (IFN)-γ, and IFN-gamma-inducible protein 10), chemokines (macrophage inflammatory protein (MIP)-1α and MIP-1ß), and growth factors (granulocyte macrophage colony stimulating factor (GM-CSF) and platelet derived growth factor) were detected at significantly higher levels in patients with metal wear debris compared with the control group. Significantly higher levels for IL-1ß, IL-5, IL-10 and GM-CSF were found in the subgroup of tissues from failed MoM THAs with a lymphocyte-dominated peri-prosthetic response compared with those without this response. These results suggest that the ‘biologically active area’ predicts the type of peri-prosthetic tissue response. The cytokines IL-1ß, IL-5, IL-10, and GM-CSF are associated with lymphocyte-dominated tissue responses from failed small-diameter MoM THA. Cite this article: Bone Joint J 2015;97-B:917–23.
Collapse
Affiliation(s)
- G. Singh
- National University Health System, 1E
Kent Ridge Road, 119228, Singapore
| | - J. V. Nuechtern
- University of Hamburg-Eppendorf, Martinistrasse
52, D-20246 Hamburg, Germany
| | - H. Meyer
- Otto-von-Guericke University, Leipziger
Strasse 44, D-39120 Magdeburg, Germany
| | - G. M. Fiedler
- Bern University Hospital, F603, CH-3010
Bern, Switzerland
| | - F. Awiszus
- Otto-von-Guericke University, Leipziger
Strasse 44, D-39120 Magdeburg, Germany
| | - S. Junk-Jantsch
- Evangelisches Krankenhaus, Hans-Sachs-Gasse
10-12, A-1180 Vienna, Austria
| | - M. Bruegel
- Ludwig-Maximilians-University, Marchioninistrasse
15, 81377 Munich, Germany
| | - G. Pflueger
- Evangelisches Krankenhaus, Hans-Sachs-Gasse
10-12, A-1180 Vienna, Austria
| | - C. H. Lohmann
- Otto-von-Guericke University, Leipziger
Strasse 44, D-39120 Magdeburg, Germany
| |
Collapse
|
12
|
Haddad FS. One step at a time. Bone Joint J 2014; 96-B:1573-4. [PMID: 25452356 DOI: 10.1302/0301-620x.96b12.35411] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|