1
|
Eardley WGP. Misunderstanding and the trochanteric fracture. Bone Joint J 2024; 106-B:430-434. [PMID: 38688492 DOI: 10.1302/0301-620x.106b5.bjj-2024-0171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/02/2024]
Affiliation(s)
- William G P Eardley
- The National Hip Fracture Database, London, UK
- James Cook University, Middlesborough, UK
| |
Collapse
|
2
|
Mayor J, Birgel V, Clausen JD, Aktas G, Sehmisch S, Einfeldt AK, Giannoudis V, Abdelaal AHK, Liodakis E. Lessons learned from biomechanical studies on cephalomedullary nails for the management of intertrochanteric fractures. A scoping review. Injury 2024; 55:111180. [PMID: 37972488 DOI: 10.1016/j.injury.2023.111180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/05/2023] [Revised: 10/29/2023] [Accepted: 10/31/2023] [Indexed: 11/19/2023]
Abstract
INTRODUCTION The increasing socioeconomic need for optimal treatment of hip fractures in combination with the high diversity of available implants has raised numerous biomechanical questions. This study aims to provide a comprehensive overview of biomechanical research on the treatment of intertrochanteric fractures using cephalomedullary devices. METHODS Following the PRISMA-P guidelines, a systematic literature search was performed on 31.12.2022. The databases PubMed/MEDLINE and Web of Science were searched. Scientific papers published between 01.01.2000 - 31.12.2022 were included when they reported data on implant properties related to the biomechanical stability for intertrochanteric fractures. Data extraction was undertaken using a synthesis approach, gathering data on criteria of implants, sample size, fracture type, bone material, and study results. RESULTS The initial search identified a total of 1459 research papers, out of which forty-three papers were considered for final analysis. Due to the heterogeneous methods and parameters used in the included studies, meta-analysis was not feasible. A comprehensive assessment of implant characteristics and outcome parameters was conducted through biomechanical analysis. Various factors such as proximal and distal locking, nail diameter and length, fracture model, and bone material were thoroughly evaluated. CONCLUSION This scoping review highlights the need for standardization in biomechanical studies on intertrochanteric fractures to ensure reliable and comparable results. Strategies such as avoiding varus, maintaining a sufficient tip-apex-distance, cement augmentation, and optimizing lesser trochanteric osteosynthesis enhance construct stability. Synthetic alternatives may offer advantages over cadaveric bone. Further research and meta-analyses are required to establish standardized protocols and enhance reliability.
Collapse
Affiliation(s)
- Jorge Mayor
- Department of Trauma Surgery, Hannover Medical School, Carl-Neuberg Str. 1, Hannover D-30625, Germany.
| | - Vera Birgel
- Hannover Medical School, Institute for Epidemiology, Social Medicine and Health Systems Research, Hannover, Germany
| | - Jan-Dierk Clausen
- Department of Trauma Surgery, Hannover Medical School, Carl-Neuberg Str. 1, Hannover D-30625, Germany
| | - Gökmen Aktas
- Department of Trauma Surgery, Hannover Medical School, Carl-Neuberg Str. 1, Hannover D-30625, Germany
| | - Stephan Sehmisch
- Department of Trauma Surgery, Hannover Medical School, Carl-Neuberg Str. 1, Hannover D-30625, Germany
| | - Ann-Kathrin Einfeldt
- Laboratory for Biomechanics and Biomaterials, Department of Orthopedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, Hannover 30625, Germany
| | - Vasilis Giannoudis
- Academic Department of Trauma & Orthopaedics, School of Medicine, University of Leeds, Leeds General Infirmary, Leeds, United Kingdom
| | - Ahmed H K Abdelaal
- Department of Orthopedic Surgery, Faculty of Medicine, Sohag University, Sohag 82524, Egypt
| | - Emmanouil Liodakis
- Department of Trauma Surgery, Hannover Medical School, Carl-Neuberg Str. 1, Hannover D-30625, Germany
| |
Collapse
|
3
|
Russell TA, Klima ML. History and Evolution of Hip Design to Decrease Failure. J Orthop Trauma 2023; 37:S49-S54. [PMID: 37710375 DOI: 10.1097/bot.0000000000002668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 07/05/2023] [Indexed: 09/16/2023]
Abstract
SUMMARY The evolution of fracture fixation designs over the past 100 years is coupled with incredible advances in materials and manufacturing technology. Failures are unavoidable and should be evaluated from the perspective of refining our technology and technique to improve patient outcomes. Failure after intramedullary fixation of hip fractures is multifactorial with contributions from an unsuccessful surgery, some preventable, some unavoidable, and rarely, design and manufacturing errors. However, whenever implants are disseminated to large population groups with variable individual anatomy, physiology, and associated comorbidities, unexpected and unpredicted weaknesses in the design and surgical technique will be discovered. Surgeons have multiple choices for nail selection with specific and critical technical requirements. The surgeon should evaluate each patient individually and determine the treatment based on patient anatomy and morphology of the fracture. The surgical approach should be modified over time after deciding how best to improve surgical treatment based on the current scientific studies.
Collapse
Affiliation(s)
- Thomas A Russell
- Department of Orthopaedic Surgery, Campbell Clinic-University of Tennessee, Memphis, TN, Prof. (ret); and
| | | |
Collapse
|
4
|
Yu F, Tang YW, Wang J, Lin ZC, Liu YB. Does intramedullary nail have advantages over dynamic hip screw for the treatment of AO/OTA31A1-A3? A meta-analysis. BMC Musculoskelet Disord 2023; 24:588. [PMID: 37464358 DOI: 10.1186/s12891-023-06715-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Accepted: 07/12/2023] [Indexed: 07/20/2023] Open
Abstract
BACKGROUND Hip fractures are still unsolved problems nowadays. We evaluated the functional outcomes and complications in the treatment of hip fractures (AO/OTA31A1-A3) to find potential difference and risk between intramedullary nail (IMN) and dynamic hip screw (DHS). METHOD We searched PubMed, Embase, Cochrane library up to 19 June 2023 and retrieved any studies comparing IMN and DHS in treatment of Hip fractures. The main outcomes and complications were extracted from the included studies. The fixed-effect model was selected to pool the data for homogeneous studies (I2 < 50%). Otherwise, the random effects model was selected (heterogeneity, I2 > 50%). The analysis of sensitivity and subgroup was performed to explore the homogeneous studies among studies. The p-value of less than 0.05 was considered statistically significant. RESULTS 30 RCT studies were included in this meta-analysis. There were significant difference of in the items of blood loss, screening time, femoral neck shortening, non-union, and femoral fractures (p < 0.05). Significant difference was found in the parameter of open reduction of fracture after sensitive analysis (p < 0.05). No significant difference was found in the parameter of Mobility Score at the last follow-up after sensitive analysis (p ≥ 0.05). There was no significant difference in the parameters of open reduction of fracture, required blood transfusion, mean surgical time, hospital stays, time to healing, mean Harris Hip Score, infection, cut out, poor reduction, breakage of implant, failure of fixation, reoperation, and systemic complications of chest infection, decubital ulcer, urinary tract infection and persistent pain in the hip (p ≥ 0.05). CONCLUSIONS Our meta-analysis revealed that hip fractures treated with IMN have merits with lower rate of blood loss, femoral neck shortening and non-union; shortcoming of increased risk of femoral fractures. It is suggested that special attention should be paid to the risk of femoral fracture when intramedullary nail was inserted in the intraoperative.
Collapse
Affiliation(s)
- Fei Yu
- College of Management, Guangdong Polytechnic Normal University, Guangzhou, China
| | - Yang-Wei Tang
- Department of Orthopedics, Huaiji People's Hospital, Zhaoqing, China
| | - Ju Wang
- Department of Orthopedics, Huaiji People's Hospital, Zhaoqing, China
| | - Zhi-Cheng Lin
- Orthopedics Center, Department of Orthopedics and Traumatology, Zhujiang Hospital, Southern Medical University, No.253. Gongye Middle Avenue, Haizhu District, Guangzhou, Guangdong, 510280, China
| | - Yu-Bin Liu
- Orthopedics Center, Department of Orthopedics and Traumatology, Zhujiang Hospital, Southern Medical University, No.253. Gongye Middle Avenue, Haizhu District, Guangzhou, Guangdong, 510280, China.
| |
Collapse
|
5
|
Raj S, Grover S, Bola H, Pradhan A, Fazal MA, Patel A. Dynamic hip screws versus cephalocondylic intramedullary nails for unstable extracapsular hip fractures in 2021: A systematic review and meta-analysis of randomised trials. J Orthop 2023; 36:88-98. [PMID: 36654796 PMCID: PMC9841034 DOI: 10.1016/j.jor.2022.12.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/01/2022] [Revised: 12/15/2022] [Accepted: 12/29/2022] [Indexed: 01/09/2023] Open
Abstract
Background Extracapsular hip fractures comprise approximately half of all hip fractures and the incidence of hip fractures is exponentially increasing. Extramedullary fixation using a dynamic hip screw (DHS) has been the gold standard method of operative treatment for unstable extracapsular fractures, however, in recent years, intramedullary nails (IMN) have become a popular alternative. IMN versus DHS is continuously discussed and debated in literature. Therefore, the purpose of this systematic review and meta-analysis is to directly compare the peri- and post-operative outcomes of these two techniques to provide an up-to-date analysis of which method of fixation is superior. Methods The MEDLINE/PubMed, Embase and Web of Science Database were searched for eligible studies from 2008 to April 2022 that compared peri- and post-operational outcomes for patients undergoing IMN or DHS operations for fixation of unstable extracapsular hip fractures (PROSPERO registration ID:CRD42021228335). Primary outcomes included mortality rate and re-operation rate. Secondary outcomes included operation time, blood loss, transfusion requirement, complication, and failure of fixation rate. The risk of bias and quality of evidence were assessed using the Cochrane RoB 2.0 tool and GRADE analysis tool, respectively. Results Of the 6776 records identified, 22 studies involving 3151 patients were included in the final review. Our meta-analysis showed no significant differences between mortality rates (10 studies, OR 0.98; 95% CI 0.80 to 1.22, p = 0.88) or re-operation rates (10 studies, OR 1.03; 95% CI 0.64 to 1.64, p = 0.91) between the two procedures. There were also no significant differences found between complication rates (17 studies, OR 1.29; 95% CI 0.79 to 2.12, p = 0.31) and failure of fixation rates (14 studies, OR 1.32; 95% CI 0.74 to 2.38, p = 0.35). However, DHS operations had a significantly longer operation time (p < 0.0001) and blood loss (p < 0.00001) than IMN operations. Conclusion Overall, based on the outcomes assessed, this review has demonstrated that there is no significant difference in the post-operative outcomes for DHS vs IMN, however a significant difference exists in two of the intraoperative outcomes assessed in this review.
Collapse
Affiliation(s)
- Siddarth Raj
- GKT School of Medical Education, King's College London, London, UK
- University Hospital Coventry and Warwickshire, NHS Trust, Coventry, UK
| | - Sarika Grover
- GKT School of Medical Education, King's College London, London, UK
- University Hospital Coventry and Warwickshire, NHS Trust, Coventry, UK
| | - Harroop Bola
- Imperial College School of Medicine, Imperial College London, London, UK
| | | | - Muhammad Ali Fazal
- Department of Trauma and Orthopaedics, Royal Free London NHS Foundation Trust, London, UK
| | - Akash Patel
- Department of Trauma and Orthopaedics, Royal Free London NHS Foundation Trust, London, UK
- School of Medicine, University College London (UCL), London, UK
| |
Collapse
|
6
|
Itou J, Kuramitsu Y, Hatta S, Okazaki K. AP3×ML3 reduction quality classification for femoral trochanteric fractures: validation for reliability focusing on positive medial cortical support. J Orthop Surg Res 2023; 18:64. [PMID: 36694258 PMCID: PMC9875386 DOI: 10.1186/s13018-023-03555-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Accepted: 01/20/2023] [Indexed: 01/26/2023] Open
Abstract
INTRODUCTION This study evaluated the validity of the AP3 × ML3 reduction quality classification, which applies the concept of positive medial cortical support. METHODS A total of 120 trochanteric fractures classified as AO Foundation/Orthopedic Trauma Association 31A1 and A2 were retrospectively analyzed. The validity of the AP3 × ML3 classification was evaluated by comparison with the Baumgaertner reduction quality criteria. When using the AP3 × ML3 classification, reduction quality was divided into three classes based on the degree of anterior cortical contact between the proximal and distal fragments. Reduction quality was also divided into three classes when using the Baumgaertner criteria. The frequency of mechanical complications, including cut-out, delayed union, and excessive migration of the lag screw, was retrospectively assessed. Intra-observer and inter-observer reliability was assessed using the intraclass correlation coefficient (ICC). RESULTS Mechanical complications included 4 cases of cutout (3.3%) and 1 of delayed union (0.8%). Mechanical complications occurred for all levels of reduction quality in both classifications, except for the acceptable of the Baumgaertner criteria. When reduction quality was rated as good, acceptable, and poor the incidence of mechanical complications was 2.5%, 5.7%, and 16%, respectively, under the AP3 × ML3 classification and 3.3%, 0%, and 15.0%, respectively, under the Baumgaertner criteria. The ICC was 0.80 for intra-observer reliability and 0.57 for inter-observer reliability when using the AP3 × ML3 classification and 0.85 and 0.34, respectively, when using the Baumgaertner criteria. CONCLUSION The AP3 × ML3 classification was reliable and easy to use compared with the widely used Baumgaertner reduction quality criteria. Level of evidence 4.
Collapse
Affiliation(s)
- Junya Itou
- grid.410818.40000 0001 0720 6587Department of Orthopaedic Surgery, Tokyo Women’s Medical University, 8-1 Kawada-Cho, Shinjuku-Ku, Tokyo, 162-8666 Japan
| | - Yujiro Kuramitsu
- grid.410818.40000 0001 0720 6587Department of Orthopaedic Surgery, Tokyo Women’s Medical University, 8-1 Kawada-Cho, Shinjuku-Ku, Tokyo, 162-8666 Japan
| | - Satoshi Hatta
- Department of Orthopaedic Surgery, Funabashi General Hospital, 1-13-1 Kitamoto-Cho, Funabashi, Chiba 273-0864 Japan
| | - Ken Okazaki
- grid.410818.40000 0001 0720 6587Department of Orthopaedic Surgery, Tokyo Women’s Medical University, 8-1 Kawada-Cho, Shinjuku-Ku, Tokyo, 162-8666 Japan
| |
Collapse
|
7
|
Swift B, Stewart A, Grammatopoulos G, Papp S, Wilkin G, Liew A. Comparing the rates and modes of failure of two third generation cephalomedullary nail systems in the treatment of intertrochanteric hip fractures. Injury 2022; 53:2846-2852. [PMID: 35725507 DOI: 10.1016/j.injury.2022.06.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 05/10/2022] [Accepted: 06/05/2022] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Cephalomedullary (CMN) implants are commonly used to address elderly intertrochanteric hip fractures. Multiple CMN implant systems exist with subtle variation between manufacturers. Multiple modes of CMN failure have been described in the literature. The present study assessed the local modes and rates of construct failure (nail fracture, cut-out and non-union) of two such implants, after a change in implant supply provided the opportunity for retrospective comparison. Additional investigation was undertaken to assess whether any predictors of failure could be identified based on common radiographic measurement parameters. METHODS Based on local implant records, all consecutive patients who suffered an intertrochanteric fracture, treated at a tertiary care hospital with a cephalomedullary nail from January 2014 to January 2018 were included. Patients were excluded if they received a CMN for pathologic fracture. Within the collection period all patients received either a Synthes Trochanteric Fixation Nail (TFN) or Zimmer Natural Nail (ZNN). Patients were retrospectively assessed for fracture reduction and implant technique parameters at the time of initial surgery. Radiographic data were assessed at minimum two years post-operatively to assess for union. Patient demographic data was followed to assess rate and mode of failure. RESULTS Six hundred and sixty-two patients were included in the study, from which a propensity matched cohort was derived. Comparing across equivalent cohorts, no differences in the rate or mode of construct failure were identified between the TFN and ZNN. When assessing the entire cohort we observed 39 construct failures (5.9%), which included 31 instances of nail cutout (4.7%), 4 episodes of nail fracture (0.6%) and 4 failures related to non-union (0.6%). Tip to apex distance, sagittal malalignment and Cleveland zone were identified as significant predictors of nail failure. CONCLUSION No difference in rates or modes of failure were identified between the TFN and ZNN constructs. Similar to previous reports we again identified the impact of tip to apex distance on construct failure and further identified Cleveland zone and sagittal malalignment as significant risks for failure.
Collapse
Affiliation(s)
- Brendan Swift
- Division of Orthopaedic Surgery, The Ottawa Hospital/University of Ottawa, Ontario, Canada
| | - Andrew Stewart
- Division of Orthopaedic Surgery, The Ottawa Hospital/University of Ottawa, Ontario, Canada
| | - George Grammatopoulos
- Division of Orthopaedic Surgery, The Ottawa Hospital/University of Ottawa, Ontario, Canada
| | - Steven Papp
- Division of Orthopaedic Surgery, The Ottawa Hospital/University of Ottawa, Ontario, Canada
| | - Geoffrey Wilkin
- Division of Orthopaedic Surgery, The Ottawa Hospital/University of Ottawa, Ontario, Canada
| | - Allan Liew
- Division of Orthopaedic Surgery, The Ottawa Hospital/University of Ottawa, Ontario, Canada.
| |
Collapse
|
8
|
Wessels JO, Bjarnesen MP, Erichsen JL, Palm H, Gundtoft PH, Viberg B. Sliding hip screw vs intramedullary nail for AO/OTA31A1-A3: a systematic review and meta-analysis. Injury 2022; 53:1149-1159. [PMID: 35027220 DOI: 10.1016/j.injury.2021.12.034] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Accepted: 12/17/2021] [Indexed: 02/02/2023]
Abstract
OBJECTIVE to conduct a systematic review with consequent meta-analysis evaluating the best treatment for Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) 31A1-A3 trochanteric fractures when comparing the sliding hip screw (SHS) to the intramedullary nail (IMN). The outcomes used for comparison are major complications (in total, as well as nonunion and infection specifically), mortality rates, functional outcomes and patient-reported outcome measures (PROM). MATERIALS AND METHODS Search strings for the Cochrane Library, CINAHL, Medline and Embase databases were developed with the help of a scientific librarian. Two authors screened the studies from the search string independently using Covidence.org and data extraction was performed similarly. Quality assessment was performed using the Cochrane Risk of Bias tool for randomised trials (ROB2) for RCT studies, and Cochrane Risk of Bias in Non-Randomised Studies - of Interventions (ROBINS-I) for non-RCT studies. Meta-analyses were performed using Log Risk Ratio as the primary effect estimate. RESULTS Of the 2,051 studies screened by the two authors, six RCTs and six non-RCTs were included in this meta-analysis, with a total of 10,402 patients. The results indicated no significant differences in total major complications, nonunion, infection or mortality between SHS and IMN treatments for AO/OTA 31A1, 31A2 and 31A3 trochanteric fractures. Due to a lack of compatible data, we were unable to perform a meta-analysis on function scores and PROM. However, there are trends that favour IMN for 31A1 and 31A2 fractures. CONCLUSION No significant difference between SHS and IMN was found in the meta-analysis in any of the examined AO/OTA fracture subtypes in terms of primary and secondary outcomes. When assessing function scores and PROM, we found trends favouring IMN for 31A1 and 31A2 fractures that should be explored further.
Collapse
Affiliation(s)
- Johanne Overgaard Wessels
- Department of Orthopaedic Surgery and Traumatology, Lillebaelt Hospital, University Hospital of Southern Denmark, Sygehusvej 24, 6000 Kolding, DK
| | - Mie Pilegaard Bjarnesen
- Department of Orthopaedic Surgery and Traumatology, Lillebaelt Hospital, University Hospital of Southern Denmark, Sygehusvej 24, 6000 Kolding, DK
| | - Julie Ladeby Erichsen
- Department of Orthopaedic Surgery and Traumatology, Lillebaelt Hospital, University Hospital of Southern Denmark, Sygehusvej 24, 6000 Kolding, DK
| | - Henrik Palm
- Department of Orthopaedic Surgery and Traumatology, Bispebjerg Hospital, DK
| | - Per Hviid Gundtoft
- Department of Orthopaedic Surgery and Traumatology, Lillebaelt Hospital, University Hospital of Southern Denmark, Sygehusvej 24, 6000 Kolding, DK
| | - Bjarke Viberg
- Department of Orthopaedic Surgery and Traumatology, Lillebaelt Hospital, University Hospital of Southern Denmark, Sygehusvej 24, 6000 Kolding, DK.
| |
Collapse
|
9
|
Lewis SR, Macey R, Lewis J, Stokes J, Gill JR, Cook JA, Eardley WG, Parker MJ, Griffin XL. Surgical interventions for treating extracapsular hip fractures in older adults: a network meta-analysis. Cochrane Database Syst Rev 2022; 2:CD013405. [PMID: 35142366 PMCID: PMC8830342 DOI: 10.1002/14651858.cd013405.pub2] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Hip fractures are a major healthcare problem, presenting a challenge and burden to individuals and healthcare systems. The number of hip fractures globally is rising. The majority of extracapsular hip fractures are treated surgically. OBJECTIVES To assess the relative effects (benefits and harms) of all surgical treatments used in the management of extracapsular hip fractures in older adults, using a network meta-analysis of randomised trials, and to generate a hierarchy of interventions according to their outcomes. SEARCH METHODS We searched CENTRAL, MEDLINE, Embase, Web of Science and five other databases in July 2020. SELECTION CRITERIA We included randomised controlled trials (RCTs) and quasi-RCTs comparing different treatments for fragility extracapsular hip fractures in older adults. We included internal and external fixation, arthroplasties and non-operative treatment. We excluded studies of hip fractures with specific pathologies other than osteoporosis or resulting from high-energy trauma. DATA COLLECTION AND ANALYSIS Two review authors independently assessed studies for inclusion. One review author completed data extraction which was checked by a second review author. We collected data for three outcomes at different time points: mortality and health-related quality of life (HRQoL) - both reported within 4 months, at 12 months and after 24 months of surgery, and unplanned return to theatre (at end of study follow-up). We performed a network meta-analysis (NMA) with Stata software, using frequentist methods, and calculated the differences between treatments using risk ratios (RRs) and standardised mean differences (SMDs) and their corresponding 95% confidence intervals (CIs). We also performed direct comparisons using the same codes. MAIN RESULTS We included 184 studies (160 RCTs and 24 quasi-RCTs) with 26,073 participants with 26,086 extracapsular hip fractures in the review. The mean age in most studies ranged from 60 to 93 years, and 69% were women. After discussion with clinical experts, we selected nine nodes that represented the best balance between clinical plausibility and efficiency of the networks: fixed angle plate (dynamic and static), cephalomedullary nail (short and long), condylocephalic nail, external fixation, hemiarthroplasty, total hip arthroplasty (THA) and non-operative treatment. Seventy-three studies (with 11,126 participants) with data for at least two of these treatments contributed to the NMA. We selected the dynamic fixed angle plate as a reference treatment against which other treatments were compared. This was a common treatment in the networks, providing a clinically appropriate comparison. We downgraded the certainty of the evidence for serious and very serious risks of bias, and because some of the estimates included the possibility of transitivity owing to the proportion of stable and unstable fractures between treatment comparisons. We also downgraded if we noted evidence of inconsistency in direct or indirect estimates from which the network estimate was derived. Most estimates included the possibility of benefits and harms, and we downgraded the evidence for these treatments for imprecision. Overall, 20.2% of participants who received the reference treatment had died by 12 months after surgery. We noted no evidence of any differences in mortality at this time point between the treatments compared. Effect estimates of all treatments included plausible benefits as well as harms. Short cephalomedullary nails had the narrowest confidence interval (CI), with 7 fewer deaths (26 fewer to 15 more) per 1000 participants, compared to the reference treatment (risk ratio (RR) 0.97, 95% CI 0.87 to 1.07). THA had the widest CI, with 62 fewer deaths (177 fewer to 610 more) per 1000 participants, compared to the reference treatment (RR 0.69, 95% CI 0.12 to 4.03). The certainty of the evidence for all treatments was low to very low. Although we ranked the treatments, this ranking should be interpreted cautiously because of the imprecision in all the network estimates for these treatments. Overall, 4.3% of participants who received the reference treatment had unplanned return to theatre. Compared to this treatment, we found very low-certainty evidence that 58 more participants (14 to 137 more) per 1000 participants returned to theatre if they were treated with a static fixed angle plate (RR 2.48, 95% CI 1.36 to 4.50), and 91 more participants (37 to 182 more) per 1000 participants returned to theatre if treated with a condylocephalic nail (RR 3.33, 95% CI 1.95 to 5.68). We also found that these treatments were ranked as having the highest probability of unplanned return to theatre. In the remaining treatments, we noted no evidence of any differences in unplanned return to theatre, with effect estimates including benefits as well as harms. The certainty of the evidence for these other treatments ranged from low to very low. We did not use GRADE to assess the certainty of the evidence for early mortality, but our findings were similar to those for 12-month mortality, with no evidence of any differences in treatments when compared to dynamic fixed angle plate. Very few studies reported HRQoL and we were unable to build networks from these studies and perform network meta-analysis. AUTHORS' CONCLUSIONS: Across the networks, we found that there was considerable variability in the ranking of each treatment such that there was no one outstanding, or subset of outstanding, superior treatments. However, static implants such as condylocephalic nails and static fixed angle plates did yield a higher risk of unplanned return to theatre. We had insufficient evidence to determine the effects of any treatments on HRQoL, and this review includes data for only two outcomes. More detailed pairwise comparisons of some of the included treatments are reported in other Cochrane Reviews in this series. Short cephalomedullary nails versus dynamic fixed angle plates contributed the most evidence to each network, and our findings indicate that there may be no difference between these treatments. These data included people with both stable and unstable extracapsular fractures. At this time, there are too few studies to draw any conclusions regarding the benefits or harms of arthroplasty or external fixation for extracapsular fracture in older adults. Future research could focus on the benefits and harms of arthroplasty interventions compared with internal fixation using a dynamic implant.
Collapse
Affiliation(s)
- Sharon R Lewis
- Bone and Joint Health, Blizard Institute, Queen Mary University of London, London, UK
| | - Richard Macey
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, Oxford, UK
| | - Joseph Lewis
- c/o Bone and Joint Health, Blizard Institute, Queen Mary University of London, London, UK
| | - Jamie Stokes
- Oxford Clinical Trials Research Unit, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, Oxford, UK
| | - James R Gill
- Department of Trauma and Orthopaedics, Cambridge University Hospitals, Cambridge, UK
| | - Jonathan A Cook
- Oxford Clinical Trials Research Unit, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, Oxford, UK
| | - William Gp Eardley
- Department of Trauma and Orthopaedics, The James Cook University Hospital, Middlesbrough, UK
| | - Martyn J Parker
- Department of Orthopaedics, Peterborough and Stamford Hospitals NHS Foundation Trust, Peterborough, UK
| | - Xavier L Griffin
- Bone and Joint Health, Blizard Institute, Queen Mary University of London, London, UK
- Barts Health NHS Trust, London, UK
| |
Collapse
|
10
|
Lewis SR, Macey R, Gill JR, Parker MJ, Griffin XL. Cephalomedullary nails versus extramedullary implants for extracapsular hip fractures in older adults. Cochrane Database Syst Rev 2022; 1:CD000093. [PMID: 35080771 PMCID: PMC8791231 DOI: 10.1002/14651858.cd000093.pub6] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
BACKGROUND Hip fractures are a major healthcare problem, presenting a substantial challenge and burden to patients, healthcare systems and society. The increased proportion of older adults in the world population means that the absolute number of hip fractures is rising rapidly across the globe. Most hip fractures are treated surgically. This Cochrane Review evaluates evidence for implants used to treat extracapsular hip fractures. OBJECTIVES To assess the relative effects of cephalomedullary nails versus extramedullary fixation implants for treating extracapsular hip fractures in older adults. SEARCH METHODS We searched CENTRAL, MEDLINE, Embase, Web of Science, the Cochrane Database of Systematic Reviews, Epistemonikos, ProQuest Dissertations & Theses, and the National Technical Information Service in July 2020. We also searched clinical trials databases, conference proceedings, reference lists of retrieved articles, and conducted backward-citation searches. SELECTION CRITERIA We included randomised controlled trials (RCTs) and quasi-RCTs comparing cephalomedullary nails with extramedullary implants for treating fragility extracapsular hip fractures in older adults. We excluded studies in which all or most fractures were caused by a high-energy trauma or specific pathologies other than osteoporosis. DATA COLLECTION AND ANALYSIS We used standard methodological procedures expected by Cochrane. We collected data for seven critical outcomes: performance of activities of daily living (ADL), delirium, functional status, health-related quality of life, mobility, mortality (reported within four months of surgery as 'early mortality'; and reported from four months onwards, with priority given to data at 12 months, as '12 months since surgery'), and unplanned return to theatre for treating a complication resulting directly or indirectly from the primary procedure (such as deep infection or non-union). We assessed the certainty of the evidence for these outcomes using GRADE. MAIN RESULTS: We included 76 studies (66 RCTs, 10 quasi-RCTs) with a total of 10,979 participants with 10,988 extracapsular hip fractures. The mean ages of participants in the studies ranged from 54 to 85 years; 72% were women. Seventeen studies included unstable trochanteric fractures; three included stable trochanteric fractures only; one included only subtrochanteric fractures; and other studies included a mix of fracture types. More than half of the studies were conducted before 2010. Owing to limitations in the quality of reporting, we could not easily judge whether care pathways in these older studies were comparable to current standards of care. We downgraded the certainty of the outcomes because of high or unclear risk of bias; imprecision (when data were available from insufficient numbers of participants or the confidence interval (CI) was wide); and inconsistency (when we noted substantial levels of statistical heterogeneity or differences between findings when outcomes were reported using other measurement tools). There is probably little or no difference between cephalomedullary nails and extramedullary implants in terms of mortality within four months of surgery (risk ratio (RR) 0.96, 95% CI 0.79 to 1.18; 30 studies, 4603 participants) and at 12 months (RR 0.99, 95% CI 0.90 to 1.08; 47 studies, 7618 participants); this evidence was assessed to be of moderate certainty. We found low-certainty evidence for differences in unplanned return to theatre but this was imprecise and included clinically relevant benefits and harms (RR 1.15, 95% CI 0.89 to 1.50; 50 studies, 8398 participants). The effect estimate for functional status at four months also included clinically relevant benefits and harms; this evidence was derived from only two small studies and was imprecise (standardised mean difference (SMD) 0.02, 95% CI -0.27 to 0.30; 188 participants; low-certainty evidence). Similarly, the estimate for delirium was imprecise (RR 1.22, 95% CI 0.67 to 2.22; 5 studies, 1310 participants; low-certainty evidence). Mobility at four months was reported using different measures (such as the number of people with independent mobility or scores on a mobility scale); findings were not consistent between these measures and we could not be certain of the evidence for this outcome. We were also uncertain of the findings for performance in ADL at four months; we did not pool the data from four studies because of substantial heterogeneity. We found no data for health-related quality of life at four months. Using a cephalomedullary nail in preference to an extramedullary device saves one superficial infection per 303 patients (RR 0.71, 95% CI 0.53 to 0.96; 35 studies, 5087 participants; moderate-certainty evidence) and leads to fewer non-unions (RR 0.55, 95% CI 0.32 to 0.96; 40 studies, 4959 participants; moderate-certainty evidence). However, the risk of intraoperative implant-related fractures was greater with cephalomedullary nails (RR 2.94, 95% CI 1.65 to 5.24; 35 studies, 4872 participants; moderate-certainty evidence), as was the risk of later fractures (RR 3.62, 95% CI 2.07 to 6.33; 46 studies, 7021 participants; moderate-certainty evidence). Cephalomedullary nails caused one additional implant-related fracture per 67 participants. We noted no evidence of a difference in other adverse events related or unrelated to the implant, fracture or both. Subgroup analyses provided no evidence of differences between the length of cephalomedullary nail used, the stability of the fracture, or between newer and older designs of cephalomedullary nail. AUTHORS' CONCLUSIONS Extramedullary devices, most commonly the sliding hip screw, yield very similar functional outcomes to cephalomedullary devices in the management of extracapsular fragility hip fractures. There is a reduced risk of infection and non-union with cephalomedullary nails, however there is an increased risk of implant-related fracture that is not attenuated with newer designs. Few studies considered patient-relevant outcomes such as performance of activities of daily living, health-related quality of life, mobility, or delirium. This emphasises the need to include the core outcome set for hip fracture in future RCTs.
Collapse
Affiliation(s)
- Sharon R Lewis
- Bone and Joint Health, Blizard Institute, Queen Mary University of London, London, UK
| | - Richard Macey
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, Oxford, UK
| | - James R Gill
- Department of Trauma and Orthopaedics, Cambridge University Hospitals, Cambridge, UK
| | - Martyn J Parker
- Department of Orthopaedics, Peterborough and Stamford Hospitals NHS Foundation Trust, Peterborough, UK
| | - Xavier L Griffin
- Bone and Joint Health, Blizard Institute, Queen Mary University of London, London, UK
- Barts Health NHS Trust, London, UK
| |
Collapse
|
11
|
Law GW, Wong YR, Gardner A, Ng YH. Intramedullary nailing confers an increased risk of medial migration compared to dynamic hip screw fixation in unstable intertrochanteric hip fractures. Injury 2021; 52:3440-3445. [PMID: 33551262 DOI: 10.1016/j.injury.2021.01.011] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 01/02/2021] [Accepted: 01/07/2021] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Medial migration of the femoral neck element (FNE) superomedially against gravity with respect to the intramedullary component of the cephalomedullary nail is a complication increasingly recognized to cause femoral head cut-out in intramedullary nailing of pertrochanteric hip fractures. Although cut-outs are common to both intra- and extramedullary fixation, especially in unstable pertrochanteric hip fractures, FNE medial migration in sliding hip screws continues to remain sparse despite increased awareness of the phenomenon. This study aims to investigate whether intramedullary nailing is biomechanically predisposed to FNE medial migration compared to extramedullary fixation with sliding hip screws to account for the discrepancy in reported FNE medial migration rates. MATERIALS AND METHODS Twelve fourth-generation synthetic femurs (Sawbones) with unstable intertrochanteric fractures were divided into 2 groups (n=6 per group). Fracture fixation was performed using the Proximal Femoral Nail Antirotation (PFNA, Synthes) (n=6) in the first group, and the Dynamic Hip Screw (DHS, Synthes) (n=6) in the second group. Both groups were subjected to bidirectional cyclic loading (600N compression loading, 120N tensile loading) at 2 Hz for 5000 cycles. The medial migration distance (MMD) was recorded at the end of the testing cycles. RESULTS The mean MMD in the PFNA group was 4.56mm (SD 0.69mm) with consistent reproduction of medial migration across all constructs tested. This was significantly more compared to the MMD of 1.17mm (SD 0.69mm) in the DHS group (p<0.001). CONCLUSION Intramedullary nailing of unstable intertrochanteric hip fractures is inherently predisposed to FNE medial migration making it more susceptible to consequent cut-out compared to fixation with the DHS.
Collapse
Affiliation(s)
- Gin Way Law
- National University Health System, Singapore.
| | | | | | - Yau Hong Ng
- National University Health System, Singapore; National University Health System, Singapore.
| |
Collapse
|
12
|
Dunne M, Kuršumović K, Fisher R, Parker M. Comparison of outcomes after different methods of fixation for extracapsular hip fractures: An observational study. Injury 2021; 52:3031-3035. [PMID: 33642086 DOI: 10.1016/j.injury.2021.02.050] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2020] [Revised: 02/06/2021] [Accepted: 02/15/2021] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Optimal management of intertrochanteric fractures using either sliding hip screws (SHS) or Intramedullary nail (IMN) fixation has long been disputed and the optimal length of a 'short nail' has yet to be clarified. Our aim was to investigate functional outcomes in patients who have undergone either sliding hip screw fixation or intramedullary fixation using varied lengths of nails to assess potential superiority. DESIGN We retrospectively reviewed data from consecutive patients with trochanteric hip fractures between January 2010 - July 2019. Fracture fixation was performed with four different devices; SHS, 220mm and 175mm Targon PFT nails or 180mm Short Affixus Hip Fracture Nails. There was no significant difference in the patient demographics in each treatment group. MAIN OUTCOME MEASURES Patients were followed up for 1 year post operatively to determine if there were differences in mobility and pain with the different fixation methods. RESULTS There was no significant difference in the overall complication rate between methods of fixation. Overall Intramedullary nail fixation resulted in an improved mean pain score compared to SHS (mean difference 0.25, 95% CI 0.11 - 0.39, p=0.0005). On sub-analysis this was only statistically significant in 220mm Targon nails (mean difference 0.35, CI 0.19-0.57, p=0.0010) and not for the other two nails. In addition, there was a significant difference in mobility score (mean difference 0.38, CI 0.12-0.63, p=0.0036). On sub-analysis this was only statistically significant favouring the for 220 mm Targon nail (mean difference 0.57, CI 0.27-0.87, p=0.0002). CONCLUSION We advise caution in interpreting the results of studies between different nails and SHS, as not all nails appear to be the same. Design features of modern nails such as length, proximal diameter, the use of a compression screw, lag screw interface within the nail and valgus inclination may all play a role in functional outcomes.
Collapse
Affiliation(s)
- Michael Dunne
- Peterborough City Hospital, North West Anglia Foundation Trust
| | | | - Rachael Fisher
- Peterborough City Hospital, North West Anglia Foundation Trust.
| | - Martyn Parker
- Peterborough City Hospital, North West Anglia Foundation Trust
| |
Collapse
|
13
|
Kanthasamy S, Guhan B, Chakravarty D, Parker MJ. The efficacy of intravenous tranexamic acid administration at induction in definitive hip fracture surgery: Is there a role? Injury 2021; 52:2361-2366. [PMID: 33568279 DOI: 10.1016/j.injury.2021.01.032] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Revised: 01/19/2021] [Accepted: 01/23/2021] [Indexed: 02/02/2023]
Abstract
UNLABELLED Tranexamic acid (TXA) is a cheap and powerful drug that has several uses in surgery and is well established in elective orthopaedic surgery. At present, limited small studies have looked into its role in the acute hip fracture. Transfusion in the geriatric population presents risks and increased costs to healthcare systems around the world. Our retrospective study looks at the role of TXA administration at induction for both intracapsular fracture requiring hemiarthroplasty and our preferred method of fixation of extracapsular fracture by intramedullary nail (IM nail). We show a statistically significant reduction in the number of patients requiring transfusion as well as mean haemoglobin (Hb) drop in those undergoing hemiarthroplasty. This was not replicated in those undergoing IM nail fixation. Both groups showed no increase in 1-year mortality or thromboembolic events following TXA administration. These results support the use of TXA for hemiarthroplasty for intracapsular hip fractures over the age of 60. OBJECTIVES The aim of this pre and post interventional study looks at the effects of intravenous administration of tranexamic acid on induction for elderly patients undergoing hemiarthroplasty or intramedullary nail fixation for hip fractures. DESIGN Pre and post interventional, randomised observational study SETTING: Large hip fracture unit, Level 2 Trauma Centre, single centre PATIENTS: Two arms of the study looking at those aged above the age of 60 undergoing hemiarthroplasty and intramedullary nail fixation without and with tranexamic acid on induction. RESULTS 12.1% of hemiarthroplasties required post-operative transfusion without tranexamic acid compared to 2.6% of those with tranexamic acid (n=15 vs n=3 respectively, p=0.006). Equally, the mean Hb drop in g/L is reduced in those with tranexamic acid compared to those without (mean Hb = 14.6 vs 17.7 respectively, p=0.034). This was not replicated in the IM nail group between those without and those with tranexamic acid (n=31 vs n=20 respectively, p= 0.16). The mean Hb drop in g/L was not statistically significant in the tranexamic acid arm compared to without (mean Hb = 19.2 vs mean Hb = 21.9, p=0.11). Gross reporting of thromboembolic events did not demonstrate an increase in the number of those with DVT, PE, MI or stroke. 1-year mortality was not statistically significant in either hemiarthroplasty or IM nail fixation following tranexamic acid administration. CONCLUSIONS Tranexamic acid both statistically significantly reduces the number of patients requiring transfusion post hemiarthroplasty and also the value of mean Hb drop without appearing to increase in thromboembolic events or 1 year mortality rates. This does not appear to be emulated in the IM nail fixation although both thrombotic events and 1-year mortality rates are also not affected by administration of TXA. We propose that TXA has a role in hemiarthroplasty surgery in reducing post-operative transfusions. LEVEL OF EVIDENCE Level 3 - retrospective cohort study.
Collapse
Affiliation(s)
- S Kanthasamy
- Surgical Teaching Fellow, Peterborough City Hospital, United Kingdom.
| | - B Guhan
- Specialty Doctor-Trauma and Orthopaedics, Peterborough City Hospital, United Kingdom.
| | - D Chakravarty
- Consultant Orthopaedic Surgeon, Fortis Hospitals, Kolkata, India
| | - Martyn J Parker
- Consultant Orthopaedic Surgeon, Peterborough City Hospital, United Kingdom.
| |
Collapse
|
14
|
Shepard S, Checketts J, Eash C, Austin J, Arthur W, Wayant C, Johnson M, Norris B, Vassar M. Evaluation of spin in the abstracts of orthopedic trauma literature: A cross-sectional review. Injury 2021; 52:1709-1714. [PMID: 34020782 DOI: 10.1016/j.injury.2021.04.060] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Revised: 04/18/2021] [Accepted: 04/24/2021] [Indexed: 02/02/2023]
Abstract
OBJECTIVES A cross-sectional analysis of orthopedic trauma randomized controlled trial (RCT) abstracts to assess the frequency and manifestations of spin, the misrepresentation or distortion of research findings, in orthopedic trauma clinical trials. METHODS The top 5 orthopedic trauma journals were searched from January 1, 2012, to December 31, 2017. RCTs with nonsignificant endpoints (p > .05) were analyzed for spin in the abstract. The primary endpoint of our investigation was the frequency and type of spin. The secondary endpoint was to assess whether funding source was associated with the presence of spin. Due to the low reporting of funding sources no statistics were able to be computed for this outcome. RESULTS Our PubMed search yielded 517 articles. Primary screening excluded 303 articles, and full text evaluation excluded an additional 161. Overall, 53 articles were included. Spin was identified in 35 of the 53 (66.0%) abstracts analyzed. Evidence of spin was found in 21 (39.6%) abstract results sections and 22 (41.5%) abstract conclusion sections. Of the 21 RCTs reporting a clinical trial registry, 3 (14.3%) had evidence of selective reporting bias. CONCLUSIONS Orthopedic trauma RCTs from highly ranked journals with nonsignificant endpoints published from 2012 to 2017 frequently have spin in their abstracts. Abstracts with evidence of spin may influence a reader's perception of new drugs or procedures. In orthopedic trauma, the implications of spin may affect the treatment of patients with orthopedic trauma, so efforts to mitigate spin in RCT abstracts must be prioritized.
Collapse
Affiliation(s)
- Samuel Shepard
- Oklahoma State University, Center for Health Sciences, 1111 W. 17th St, Tulsa, OK, 74107 USA
| | - Jake Checketts
- Oklahoma State University, Center for Health Sciences, 1111 W. 17th St, Tulsa, OK, 74107 USA
| | - Colin Eash
- Oklahoma State University, Center for Health Sciences, 1111 W. 17th St, Tulsa, OK, 74107 USA
| | - Jennifer Austin
- Oklahoma State University, Center for Health Sciences, 1111 W. 17th St, Tulsa, OK, 74107 USA
| | - Wade Arthur
- Oklahoma State University, Center for Health Sciences, 1111 W. 17th St, Tulsa, OK, 74107 USA
| | - Cole Wayant
- Oklahoma State University, Center for Health Sciences, 1111 W. 17th St, Tulsa, OK, 74107 USA
| | - Mark Johnson
- Oklahoma State University Medical Center - Department of Orthopaedics USA
| | - Brent Norris
- Oklahoma State University Medical Center - Department of Orthopaedics USA; Orthopaedic & Trauma Services of Oklahoma USA
| | - Matt Vassar
- Oklahoma State University, Center for Health Sciences, 1111 W. 17th St, Tulsa, OK, 74107 USA
| |
Collapse
|
15
|
Chen J, Yue C, He P, Huang Z, Li L, Zhang X, Fan Y, Liu Y. Comparison of clinical outcomes with hip replacement versus PFNA in the treatment of intertrochanteric fractures in the elderly: A systematic review and meta-analysis (PRISMA). Medicine (Baltimore) 2021; 100:e24166. [PMID: 33655910 PMCID: PMC7939162 DOI: 10.1097/md.0000000000024166] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/17/2020] [Accepted: 12/10/2020] [Indexed: 01/17/2023] Open
Abstract
BACKGROUND The purpose of this meta-analysis was to evaluate the clinical efficacy and safety of HR and PFNA in the treatment of intertrochanteric fractures in the elderly. METHODS We carried out this review according to the principle of preferred reporting items for systematic reviews and meta-analyses (PRISMA) guideline. The clinical randomized controlled trials (RCTs), prospective cohort studies, retrospective cohort studies (RCSs), and case-control studies involving HR and PFNA in the treatment of intertrochanteric fractures in the elderly from 2000 to 2020 were compared by searching Web of Science, Pubmed, the Cochrane Library, and Embase. The quality of the included cohort study (CS) lines was evaluated using the Newcastle-Ottawa Scale (NOS). The quality of the included RCT lines was evaluated using Jadad. Forest plots were drawn by RevMan5.4 software based on the results and the data were analyzed. RESULTS After screening, a total of 9 articles were included, of which one was a clinical RCT and eight were RCSs with 1374 patients. The operative time of the PFNA group was shorter [WMD = 15.20; 95% CI (13.17, 17.23), P < .05] and the intraoperative blood loss was less [WMD = 178.81; 95% CI (97.24, 260.38), P < .05] than the HR group, while the first weight-bearing time of the HR group was shorter [WMD = -7.70; 95% CI (-10.54, -4.86), P < .05] than the PFNA group. There was no significant difference in the length of hospital stay, HHS, postoperative orthopedic complications, and postoperative medical complications between the 2 groups. CONCLUSION With the development of HR technology and minimally invasive technology, the trauma caused by surgery is decreasing. Under the premise of improving perioperative management, such as optimizing the preoperative preparation and postoperative management, shortening the operative time, reducing intraoperative blood loss, and actively managing co-existing diseases, HR has more advantages than PFNA in the treatment of senile intertrochanteric fractures.
Collapse
Affiliation(s)
- Junming Chen
- Key Laboratory of Orthopedics & Traumatology of Traditional Chinese Medicine and Rehabilitation (Fujian University of TCM), Ministry of Education, Fujian University of Traditional Chinese Medicine, Fuzhou
| | - Chen Yue
- Department of Orthopedic Surgery, Luoyang Orthopedic Hospital of Henan Province, Orthopedic Hospital of Henan Province, Luoyang, China
| | - Peilin He
- Key Laboratory of Orthopedics & Traumatology of Traditional Chinese Medicine and Rehabilitation (Fujian University of TCM), Ministry of Education, Fujian University of Traditional Chinese Medicine, Fuzhou
| | - Zeling Huang
- Key Laboratory of Orthopedics & Traumatology of Traditional Chinese Medicine and Rehabilitation (Fujian University of TCM), Ministry of Education, Fujian University of Traditional Chinese Medicine, Fuzhou
| | - Li Li
- Key Laboratory of Orthopedics & Traumatology of Traditional Chinese Medicine and Rehabilitation (Fujian University of TCM), Ministry of Education, Fujian University of Traditional Chinese Medicine, Fuzhou
| | - Xue Zhang
- Department of Orthopedic Surgery, Luoyang Orthopedic Hospital of Henan Province, Orthopedic Hospital of Henan Province, Luoyang, China
| | - Yanan Fan
- Department of Orthopedic Surgery, Luoyang Orthopedic Hospital of Henan Province, Orthopedic Hospital of Henan Province, Luoyang, China
| | - Youwen Liu
- Department of Orthopedic Surgery, Luoyang Orthopedic Hospital of Henan Province, Orthopedic Hospital of Henan Province, Luoyang, China
| |
Collapse
|
16
|
Mellema JJ, Janssen S, Schouten T, Haverkamp D, van den Bekerom MPJ, Ring D, Doornberg JN. Intramedullary nailing versus sliding hip screw for A1 and A2 trochanteric hip fractures. Bone Joint J 2021; 103-B:775-781. [PMID: 33591214 DOI: 10.1302/0301-620x.103b.bjj-2020-1490.r1] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS This study evaluated variation in the surgical treatment of stable (A1) and unstable (A2) trochanteric hip fractures among an international group of orthopaedic surgeons, and determined the influence of patient, fracture, and surgeon characteristics on choice of implant (intramedullary nailing (IMN) versus sliding hip screw (SHS)). METHODS A total of 128 orthopaedic surgeons in the Science of Variation Group evaluated radiographs of 30 patients with Type A1 and A2 trochanteric hip fractures and indicated their preferred treatment: IMN or SHS. The management of Type A3 (reverse obliquity) trochanteric fractures was not evaluated. Agreement between surgeons was calculated using multirater kappa. Multivariate logistic regression models were used to assess whether patient, fracture, and surgeon characteristics were independently associated with choice of implant. RESULTS The overall agreement between surgeons on implant choice was fair (kappa = 0.27 (95% confidence interval (CI) 0.25 to 0.28)). Factors associated with preference for IMN included USA compared to Europe or the UK (Europe odds ratio (OR) 0.56 (95% CI 0.47 to 0.67); UK OR 0.16 (95% CI 0.12 to 0.22); p < 0.001); exposure to IMN only during training compared to surgeons that were exposed to both (only IMN during training OR 2.6 (95% CI 2.0 to 3.4); p < 0.001); and A2 compared to A1 fractures (Type A2 OR 10 (95% CI 8.4 to 12); p < 0.001). CONCLUSION In an international cohort of orthopaedic surgeons, there was a large variation in implant preference for patients with A1 and A2 trochanteric fractures. This is due to surgeon bias (country of practice and aspects of training). The observation that surgeons favoured the more expensive implant (IMN) in the absence of convincing evidence of its superiority suggests that surgeon de-biasing strategies may be a useful focus for optimizing patient outcomes and promoting value-based healthcare. Cite this article: Bone Joint J 2021;103-B(4):775-781.
Collapse
Affiliation(s)
- Jos J Mellema
- Department of Orthopaedic Surgery, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Stein Janssen
- Department of Orthopaedic Surgery, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Tundi Schouten
- Department of Orthopaedic Surgery, HagaZiekenhuis, The Hague, The Netherlands
| | | | | | - David Ring
- Department of Surgery and Perioperative Care, Dell Medical School, The University of Texas at Austin, Austin, Texas, USA
| | - Job N Doornberg
- Department of Orthopaedic Surgery, Groningen University Medical Centre, Groningen, The Netherlands
| | | |
Collapse
|
17
|
Law GW, Koh J, Yew A, Howe TS. Scanning Electron Microscopy Study of Retrieved Implants Suggests a Ratcheting Mechanism Behind Medial Migration in Cephalomedullary Nailing of Hip Fractures. Malays Orthop J 2020; 14:7-17. [PMID: 32296476 PMCID: PMC7156168 DOI: 10.5704/moj.2003.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/05/2022] Open
Abstract
Introduction: Medial migration is the paradoxical migration of the femoral neck element (FNE) superomedially against gravity with respect to the intramedullary component of the cephalomedullary device, increasingly seen in the management of pertrochanteric hip fractures with the intramedullary nail. We postulate that the peculiar anti-gravity movement of the FNE in the medial migration phenomenon stems from a ratcheting mechanism at the intramedullary nail-FNE interface, which should inadvertently produce unique wear patterns on the FNE that can be seen with high-powered microscopy. By examining the wear patterns on retrieved implants from patients with medial migration, our study aims to draw clinical correlations to the ratcheting mechanism hypothesis. Material and Methods: Four FNEs were retrieved from revision surgeries of four patients with prior intramedullary nail fixation of their pertrochanteric hip fractures complicated by femoral head perforation. The FNEs were divided into two groups based on whether or not there was radiographic evidence of medial migration prior to the revisions. Wear patterns on the FNEs were then assessed using both scanning electron microscopy and light microscopy. Results: Repetitive, linearly-arranged, regularly-spaced, unique transverse scratch marks were found only in the group with medial migration, corresponding to the specific segment of the FNE that passed through the intramedullary component of the PFNA during medial migration. These scratch marks were absent in the group without medial migration. Conclusion: Our findings are in support of a ratcheting mechanism behind the medial migration phenomenon with repetitive toggling at the intramedullary nail-FNE interface and progressive propagation of the FNE against gravity.
Collapse
Affiliation(s)
- G W Law
- Department of Orthopaedic Surgery, Singapore General Hospital, Singapore
| | - Jsb Koh
- Department of Orthopaedic Surgery, Singapore General Hospital, Singapore
| | - Aks Yew
- Department of Orthopaedic Surgery, Singapore General Hospital, Singapore
| | - T S Howe
- Department of Orthopaedic Surgery, Singapore General Hospital, Singapore
| |
Collapse
|
18
|
Parker MJ, Cawley S. Short (175 mm) versus standard (220 mm) length intramedullary nail for trochanteric hip fractures: a randomized trial of 229 patients. Bone Joint J 2020; 102-B:394-399. [PMID: 32114812 DOI: 10.1302/0301-620x.102b3.bjj-2019-0776.r3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS A lack of supporting clinical studies have been published to determine the ideal length of intramedullary nail in fixation of trochanteric fractures of the hip. Nevertheless, there has been a trend to use shorter intramedullary nails for the internal fixation of trochanteric hip fractures. Our aim was to determine if the length of nail affected the outcome. METHODS We randomized 229 patients with a trochanteric hip fracture between two implants: a 'standard' nail of 220 mm and a shorter nail of 175 mm, which had decreased proximal angulation (4° vs 7°) and a reduced diameter at the level of the lesser trochanter. Patients were followed up for one year by a nurse blinded to the type of implant used to determine if there were differences in mobility and pain with two nail designs. Pain was assessed on a scale of 1 (none) to 8 (severe and constant) and mobility on a scale of 1 (full mobility) to 9 (immobile). RESULTS The shorter nail did not require any reaming of the femur and was quicker to insert (mean difference 5.1 minutes; p < 0.001, 95% confidence interval (CI) of the difference 3.16 to 7.04). Those treated by the shorter nail were less mobile (mean difference in reduction in mobility score at one year 0.80; p = 0.007, 95% CI 1.38 to 0.22). In addition, there was a trend toward greater residual pain for those treated with the shorter nail, although this was not statistically significant (mean difference in pain score at one year 0.24; p = 0.064, 95% CI -0.01 to 0.49). CONCLUSION These results suggest that the increasing use of this very short intramedullary nail with its design modification may not be appropriate. Cite this article: Bone Joint J 2020;102-B(3):394-399.
Collapse
Affiliation(s)
- Martyn J Parker
- Department of Orthopaedics, Peterborough City Hospital, Peterborough and Stamford Hospital NHS Foundation Trust, Peterborough, UK
| | - Shirley Cawley
- Department of Orthopaedics, Peterborough City Hospital, Peterborough and Stamford Hospital NHS Foundation Trust, Peterborough, UK
| |
Collapse
|
19
|
Abstract
OBJECTIVE To investigate an association between a surgeon's choice of a cephalomedullary nail (CMN) or sliding hip screw (SHS) with the cost of treating a pertrochanteric hip fracture. DESIGN Multicenter retrospective cohort study. SETTING US Veterans Health Administration Sierra Pacific Network. PATIENTS/PARTICIPANTS Two hundred ninety-four consecutive US veterans admitted for a principal diagnosis of an OTA/AO 31A-type pertrochanteric hip fracture of a native hip from 2000 to 2015. INTERVENTION Internal fixation using a CMN or an SHS. MAIN OUTCOME MEASUREMENTS Veterans Administration Health Economic Resource Center average national cost estimate of combined acute and postacute care episode cost, excluding implant cost, normalized to 2015 US dollars by the Consumer Price Index. RESULTS Median episode cost was $8223 lower with a CMN than an SHS (95% confidence interval, $5700-$10,746, P < 0.001) after matching on a propensity score for treatment with a CMN based on age, sex, body mass index, Charlson Comorbidity Index, fracture characteristics, study site, and admission year. A subgroup propensity-matched analysis excluding reverse obliquity pertrochanteric fractures was not sufficiently powered to detect a difference in episode cost (β = 0.76, P = 0.311). CONCLUSIONS Implant choice significantly affected the episode cost of care of hip fracture at Veterans Health Administration facilities. LEVEL OF EVIDENCE Economic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
20
|
Mobility after intertrochanteric hip fracture fixation with either a sliding hip screw or a cephalomedullary nail: Sub group analysis of a randomised trial of 1000 patients. Injury 2019; 50:1709-1714. [PMID: 31256911 DOI: 10.1016/j.injury.2019.06.015] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/17/2019] [Accepted: 06/18/2019] [Indexed: 02/02/2023]
Abstract
AIMS The aim of this study was to determine if different patient groups have superior mobility regain following intertrochanteric hip fracture fixation with a cephomedullary nail compared to a sliding hip screw (SHS). PATIENTS AND METHODS The present study is a subgroup analysis of patients which were enrolled into a randomized controlled trial which randomized 1000 patients with an intertrochanteric hip fracture to fixation with either a short cephomedullary nail (Targon® PF or PFT) or a SHS. In the present study the two treatment groups were dicotomised on the basis of six variables determined at the time of admission; age (<80; ≥80 years), sex, residence (admitted from own home; institutional care), mobility (mobility score ≥7 [good]; <7 [poor]), mental status (AMTS < 7 [cognitively impaired]; ≥7) and health status (ASA < 3; ≥3). The primary outcome measure was the difference between mobility score pre-fracture and mobility score during the year after hip fracture fixation. RESULTS Patients less than 80 years of age, those admitted from their own home, cognitively intact patients and patients who mobilised without assistance pre-fracture, recovered superior mobility when fracture fixation was performed with a nail compared to a SHS. Those patients admitted from institutional care, those with significant cognitive or mobility impairment at the time of the injury did not have any significantly improved benefit in mobility regain with a nail compared to a SHS. CONCLUSION Fixation of an intertrochanteric hip fracture with a cephomedullary nail results in superior recovery of mobility for younger patients who prior to the injury were more mobile, cognitively intact and living at home.
Collapse
|
21
|
Warren JA, Sundaram K, Hampton R, McLaughlin J, Patterson B, Higuera CA, Piuzzi NS. Cephalomedullary nailing versus sliding hip screws for Intertrochanteric and basicervical hip fractures: a propensity-matched study of short-term outcomes in over 17,000 patients. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2019; 30:243-250. [PMID: 31486944 DOI: 10.1007/s00590-019-02543-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Accepted: 08/29/2019] [Indexed: 12/13/2022]
Abstract
BACKGROUND Hip fractures are associated with poor mortality and morbidity outcomes. Controversy exists over what the preferred treatment is between sliding hips screws (SHSs) and cephalomedullary nails (CMNs) for stable intertrochanteric (IT) and basicervical (BC) hip fractures. The purpose of this study was to compare early postoperative outcomes and complications in patients treated with SHS to those treated with CMN in IT and BC hip fractures. METHODS We used the National Surgical Quality Improvement Program database to identify IT and BC hip fractures, excluding subtrochanteric hip fractures treated with a SHS and CMN for 2008 to 2016. After propensity score matching, there were 8505 patients in the SHS cohort and 8505 in the CMN cohort. Propensity score-adjusted multivariate regression models assed SHS as an independent risk factor for the following 30-day outcomes: mortality, postoperative major and minor complications, discharge disposition, readmission and reoperation, length of hospital stay (LOS), and operative time. RESULTS No difference in mortality was encountered between SHS and CMN (p = 0.440). Compared to CMN, the SHS cohort had an 11.6% decreased likelihood of a minor complication (p < 0.001); however, no difference was found between CMN and SHS for major complications (p = 0.117). SHS patients were less likely to have transfusion (p < 0.001), DVT (p = 0.007), and MI (0.024). SHS patients were 12.5% more likely to go home (p = 0.002). No association was discovered between being treated with a SHS and reoperation (p = 0.449) and readmission (p = 0.588). SHS patients had almost a quarter of a day longer LOS (p = 0.041). Patients treated with SHS had a statistically significant (p < 0.001), but clinically irrelevant 2-min longer procedure. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Jared A Warren
- Department of Orthopedic Surgery, Cleveland Clinic, Orthopaedic and Rheumatology Institute, 9500 Euclid Avenue, A41, Cleveland, OH, 44195, USA
| | - Kavin Sundaram
- Department of Orthopedic Surgery, Cleveland Clinic, Orthopaedic and Rheumatology Institute, 9500 Euclid Avenue, A41, Cleveland, OH, 44195, USA
| | - Robert Hampton
- Department of Orthopedic Surgery, Cleveland Clinic, Orthopaedic and Rheumatology Institute, 9500 Euclid Avenue, A41, Cleveland, OH, 44195, USA
| | - John McLaughlin
- Department of Orthopedic Surgery, Cleveland Clinic, Orthopaedic and Rheumatology Institute, 9500 Euclid Avenue, A41, Cleveland, OH, 44195, USA
| | - Brendan Patterson
- Department of Orthopedic Surgery, Cleveland Clinic, Orthopaedic and Rheumatology Institute, 9500 Euclid Avenue, A41, Cleveland, OH, 44195, USA
| | - Carlos A Higuera
- Department of Orthopedic Surgery, Cleveland Clinic Florida, Weston, FL, USA
| | - Nicolas S Piuzzi
- Department of Orthopedic Surgery, Cleveland Clinic, Orthopaedic and Rheumatology Institute, 9500 Euclid Avenue, A41, Cleveland, OH, 44195, USA.
| |
Collapse
|
22
|
Law GW, Wong YR, Yew AKS, Choh ACT, Koh JSB, Howe TS. Medial migration in cephalomedullary nail fixation of pertrochanteric hip fractures: A biomechanical analysis using a novel bidirectional cyclic loading model. Bone Joint Res 2019; 8:313-322. [PMID: 31463040 PMCID: PMC6691370 DOI: 10.1302/2046-3758.87.bjr-2018-0271.r1] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Objectives The paradoxical migration of the femoral neck element (FNE) superomedially against gravity, with respect to the intramedullary component of the cephalomedullary device, is a poorly understood phenomenon increasingly seen in the management of pertrochanteric hip fractures with the intramedullary nail. The aim of this study was to investigate the role of bidirectional loading on the medial migration phenomenon, based on unique wear patterns seen on scanning electron microscopy of retrieved implants suggestive of FNE toggling. Methods A total of 18 synthetic femurs (Sawbones, Vashon Island, Washington) with comminuted pertrochanteric fractures were divided into three groups (n = 6 per group). Fracture fixation was performed using the Proximal Femoral Nail Antirotation (PFNA) implant (Synthes, Oberdorf, Switzerland; n = 6). Group 1 was subjected to unidirectional compression loading (600 N), with an elastomer (70A durometer) replacing loose fracture fragments to simulate surrounding soft-tissue tensioning. Group 2 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading), also with the elastomer replacing loose fracture fragments. Group 3 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading) without the elastomer. All constructs were tested at 2 Hz for 5000 cycles or until cut-out occurred. The medial migration distance (MMD) was recorded at the end of the testing cycles. Results The MMDs for Groups 1, 2, and 3 were 1.02 mm, 6.27 mm, and 5.44 mm respectively, with reliable reproduction of medial migration seen in all groups. Bidirectional loading groups showed significantly higher MMDs compared with the unidirectional loading group (p < 0.01). Conclusion Our results demonstrate significant contributions of bidirectional cyclic loading to the medial migration phenomenon in cephalomedullary nail fixation of pertrochanteric hip fractures. Cite this article: G. W. Law, Y. R. Wong, A. K-S. Yew, A. C. T. Choh, J. S. B. Koh, T. S. Howe. Medial migration in cephalomedullary nail fixation of pertrochanteric hip fractures: A biomechanical analysis using a novel bidirectional cyclic loading model. Bone Joint Res 2019;8:313–322. DOI: 10.1302/2046-3758.87.BJR-2018-0271.R1.
Collapse
Affiliation(s)
- G W Law
- Department of Orthopaedic Surgery, Singapore General Hospital, Singapore, Singapore
| | - Y R Wong
- Singapore General Hospital, Singapore, Singapore
| | - A K-S Yew
- Singapore General Hospital, Singapore, Singapore
| | - A C T Choh
- Singapore General Hospital, Singapore, Singapore
| | - J S B Koh
- Department of Orthopaedic Surgery, Singapore General Hospital, Singapore, Singapore
| | - T S Howe
- Department of Orthopaedic Surgery, Singapore General Hospital, Singapore, Singapore
| |
Collapse
|
23
|
Smith A, Denehy K, Ong KL, Lau E, Hagan D, Malkani A. Total hip arthroplasty following failed intertrochanteric hip fracture fixation treated with a cephalomedullary nail. Bone Joint J 2019; 101-B:91-96. [PMID: 31146562 DOI: 10.1302/0301-620x.101b6.bjj-2018-1375.r1] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS Cephalomedullary nails (CMNs) are commonly used for the treatment of intertrochanteric hip fractures. Total hip arthroplasty (THA) may be used as a salvage procedure when fixation fails in these patients. The aim of this study was to analyze the complications of THA following failed intertrochanteric hip fracture fixation using a CMN. PATIENTS AND METHODS Patients who underwent THA were identified from the 5% subset of Medicare Parts A/B between 2002 and 2015. A subgroup involving those with an intertrochanteric fracture that was treated using a CMN during the previous five years was identified and compared with the remaining patients who underwent THA. The length of stay (LOS) was compared using both univariate and multivariate analysis. The incidence of infection, dislocation, revision, and re-admission was compared between the two groups, using multivariate analysis adjusted for demographic, hospital, and clinical factors. RESULTS The Medicare data yielded 56 522 patients who underwent primary THA, of whom 369 had previously been treated with a CMN. The percentage of THAs that were undertaken between 2002 and 2005 in patients who had previously been treated with a CMN (0.346%) more than doubled between 2012 and 2015 (0.781%). The CMN group tended to be older and female, and to have a higher Charlson Comorbidity Index and lower socioeconomic status. The mean LOS was 1.5 days longer (5.3 vs 3.8) in the CMN group (p < 0.0001). The incidence of complications was significantly higher in the CMN group compared with the non-CMN group: infection (6.2% vs 2.6%), dislocation (8.1% vs 4.5%), revision (8.4% vs 4.3%), revision for infection (1.1% vs 0.37%), and revision for dislocation (2.2% vs 0.6%). CONCLUSION The incidence of conversion to THA following failed intertrochanteric hip fracture fixation using a CMN continues to increase. This occurs in elderly patients with increased comorbidities. There is a significantly increased risk of infection, dislocation, and LOS in these patients. Patients with failed intertrochanteric hip fracture fixation using a CMN who require THA should be made aware of the increased risk of complications, and steps need to be taken to reduce this risk. Cite this article: Bone Joint J 2019;101-B(6 Supple B):91-96.
Collapse
Affiliation(s)
- A Smith
- Department of Orthopaedic Surgery, University of Louisville, Louisville, Kentucky, USA
| | - K Denehy
- Department of Orthopaedic Surgery, University of Louisville, Louisville, Kentucky, USA
| | - K L Ong
- Exponent Inc., Philadelphia, Pennsylvania, USA
| | - E Lau
- Exponent Inc., Menlo Park, California, USA
| | - D Hagan
- School of Medicine, University of Louisville, Louisville, Kentucky, USA
| | - A Malkani
- Adult Reconstruction Program, University of Louisville, KentuckyOne Health, Louisville, Kentucky, USA
| |
Collapse
|
24
|
Haddon J, Buciuto R, Johnsen LG. A prospective randomized trial of 100 patients using trochanteric support plates; worth their mettle? Injury 2019; 50:733-737. [PMID: 30797542 DOI: 10.1016/j.injury.2019.01.035] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2018] [Revised: 12/19/2018] [Accepted: 01/30/2019] [Indexed: 02/02/2023]
Abstract
BACKGROUND AND PURPOSE To compare the radiological and clinical results of sliding hip screw (SHS) fixation with or without a Trochanteric Support Plate (TSP) on unstable three-or-more-part trochanteric fractures. METHODS A randomized prospective non blinded study of one hundred patients with trochanteric fractures; Evans-Jensen type 3, 4 and 5, reduced and fixed with SHS. Patients were randomized into two study groups; with or without TSP supplementation ('TSP' and 'NoTSP' groups). Radiologic measurements of the hip in the frontal plane (primary outcome), including fracture movement, nonunion and loss of fixation were measured, as well as pain, ambulation, mobility, institution residence, complications and death, twelve months post operatively (secondary outcomes). RESULTS At one-year follow-up four patients in the TSP and ten patients in the NoTSP group had either died or been lost in follow-up. Within this period, forty-three fractures healed and three had a loss of fixation in the TSP group; thirty-nine fractures healed and one had a loss of fixation in the NoTSP group. Frontal X-rays showed fracture subsidence on average 1 mm less in the TSP group compared to the NoTSP group. This difference was negligible, as was the difference in all subgroups, in fixation failure/cutout, modified Merle d'Aubigne Postel scores (measuring function and pain), institution residence, complications and death between the groups. INTERPRETATION This study cannot confirm that TSP has any beneficial effects on unstable three-or-more-part trochanteric fractures. If any effect at all, the difference is most likely slight and clinically irrelevant.
Collapse
Affiliation(s)
- James Haddon
- Orthopedic Trauma Unit, Department of Orthopedic Surgery, St. Olavs University Hospital, Trondheim, Norway.
| | - Robert Buciuto
- Orthopedic Trauma Unit, Department of Orthopedic Surgery, St. Olavs University Hospital, Trondheim, Norway
| | - Lars G Johnsen
- Orthopedic Trauma Unit, Department of Orthopedic Surgery, St. Olavs University Hospital, Trondheim, Norway
| |
Collapse
|
25
|
Parker MJ. Sliding hip screw versus intramedullary nail for trochanteric hip fractures; a randomised trial of 1000 patients with presentation of results related to fracture stability. Injury 2017; 48:2762-2767. [PMID: 29102044 DOI: 10.1016/j.injury.2017.10.029] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/08/2017] [Revised: 10/12/2017] [Accepted: 10/18/2017] [Indexed: 02/02/2023]
Abstract
AIMS To determine the optimum choice of implant for a patient with a the different types of trochanteric hip fracture. PATIENTS AND METHODS 1000 patients with a trochanteric hip fracture were randomised to internal fixation of the fracture with either a Sliding Hip Screw or an intramedullary nail. Fractures were subdivided into two part fractures, comminuted fractures and fractures at the level of the lesser trochanter (reversed/oblique and transverse). Functional assessment for up to one year from injury was undertaken by a research nurse blinded to the treatment allocation. RESULTS The mean age of patients was 82years and 77% were female. There was a significantly improved regain of mobility for those treated with the intramedullary nail. No statistically significant differences between the two types of fixation methods was observed for mortality, fracture healing complications, re-operations, hospital stay, length of surgery, blood transfusion requirements, medical complications, degree of residual pain or regain of independence. These finding were valid for all fracture types. CONCLUSION This study is the first adequately powered randomised trial on this topic and demonstrates that there are no notable differences in either process or functional outcomes between these two treatment methods, other than a tendency to better regain of mobility for those fractures fixed with an intramedullary nail.
Collapse
Affiliation(s)
- Martyn J Parker
- Department of Orthopaedics, Peterborough City Hospital, Peterborough and Stamford Hospital NHS Foundation Trust, Bretton Gate, Peterborough PE3 9GZ, England, United Kingdom.
| |
Collapse
|