1
|
Spierenburg W, de Vries AJ, Boomsma MF, Siepelinga S, Wetzels T, van Raaij JJAM. No Difference in Revision Rates and High Survival Rates in Large-head Metal-on-metal THA Versus Metal-on-polyethylene THA: Long-term Results of a Randomized Controlled Trial. Clin Orthop Relat Res 2024; 482:1173-1182. [PMID: 38084856 PMCID: PMC11219146 DOI: 10.1097/corr.0000000000002924] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Accepted: 10/17/2023] [Indexed: 07/04/2024]
Abstract
BACKGROUND Pseudotumor formation is a well-known complication in metal-on-metal (MoM) THA. Pseudotumors combined with elevated serum ion levels and complaints from patients can lead to high revision rates. Long-term (> 10 years) results obtained from randomized trials comparing large-head MoM THA and conventional metal-on-polyethylene (MoP) THA are lacking regarding revision and survival rates, pseudotumor formation, functional outcomes, and serum ion levels. QUESTIONS/PURPOSES At 10 years of follow-up, (1) what is the difference in survival and revision rates between large-head (38 to 60 mm) MoM THA and conventional 28-mm MoP THA? (2) What is the difference in pseudotumor formation between large-head MoM THA and MoP THA? (3) Is there a difference in functional outcome between large-head MoM THA and MoP THA? (4) What is the difference in serum ion levels between large-head MoM THA and MoP THA? METHODS Between January 2006 and December 2008, 104 patients were randomized to receive either cementless MoM THA (50 patients) or cementless MoP THA (54 patients). In all, 78% (81 of 104) of patients completed the 10-year postoperative follow-up: 36 patients with MoM THA (72%; six patients lost to follow-up) and 45 with MoP THA (83%; four lost to follow-up). In the MoM group, 47% (17) were men, and the patients had a mean ± SD age of 60 ± 5 years. In the MoP group, 38% (17) were men, and the patients had a mean age of 61 ± 5 years. All baseline characteristics were similar between the groups. At 10 years of follow-up, all patient records were screened for revision surgery or complications, and the primary endpoint was survivorship free from revision for any cause at the 10-year follow-up interval, which we analyzed using a Kaplan-Meier survival analysis. All patients had a CT scan to determine the pseudotumor classification, which was reviewed by an independent radiologist. Functional outcome was measured using the patient-reported Oxford Hip Score and Harris Hip Score; the latter was assessed by a blinded nurse practitioner. Finally, serum ion cobalt and chrome concentrations were measured at 10 years postoperatively. Because the a priori sample size calculation for this randomized controlled trial was based on a different endpoint, a post hoc power analysis was performed for this long-term follow-up study, with survival as the primary outcome. It showed that considering the number of included patients, this study would have sufficient power (one-sided testing, alpha 0.05, power 80%) to discern a difference of 20% in the survival rate between the MoP and MoM groups (95% versus 75%). RESULTS With the numbers available, there was no difference in survivorship free from revision for any cause between the MoP group and MoM group at 10 years (95% [95% CI 85% to 98%] versus 92% [95% CI 82% to 98%]; p = 0.6). A higher percentage of patients in the MoM group had pseudotumors on CT than those in the MoP group did, but pseudotumors were observed in both groups (56% [20 of 36] in the MoM group versus 22% [10 of 45] in the MoP group, relative risk 1.8 [95% CI 1.2 to 2.6]; p = 0.002). A higher proportion of elevated cobalt and chrome levels was found in the MoM group (19% and 14%, respectively) than in the MoP group (0% for both cobalt and chrome) (cobalt: RR 1.2 [95% CI 1.1 to 1.5]; p = 0.002; chrome: RR 1.2 [95% CI 1.0 to 1.3]; p = 0.01). In 25% of the patients with pseudotumors (5 of 20 patients), there were elevated serum cobalt levels. None of the 23 patients without pseudotumors had elevated cobalt levels (RR 1.3 [95% CI 1.0 to 1.7]; p = 0.01). There was no difference in functional outcome between study groups, nor a difference between patients with a pseudotumor and those without. CONCLUSION This study showed that the survival of patients with large-head MoM THA was high and comparable to that of those with MoP THA, which contrasts with the high revision rates reported by others. Although some patients with MoP THAs experienced pseudotumors, the risk of a pseudotumor was much greater in MoM hips, and serum ion levels were higher in patients who received an MoM THA. For these reasons and unknown future complications, continued surveillance of patients with MoM THAs seems important. LEVEL OF EVIDENCE Level I, therapeutic study.
Collapse
Affiliation(s)
| | | | | | - S. Siepelinga
- Department of Orthopedics, Martini Hospital, Groningen, the Netherlands
| | - Tom Wetzels
- Department of Orthopedics, Sint-Andries Hospital, Tielt, the Netherlands
| | | |
Collapse
|
2
|
Akçaalan S, Kengil MC, Çağlar C, Uğurlu M. Is there still an indication for the Birmingham Hip Resurfacing in femoral head osteonecrosis? INTERNATIONAL ORTHOPAEDICS 2024; 48:1157-1163. [PMID: 38165447 DOI: 10.1007/s00264-023-06070-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Accepted: 12/11/2023] [Indexed: 01/03/2024]
Abstract
PURPOSE Osteonecrosis of the femoral head (ONFH) is a progressive hip disease. Hip resurfacing arthroplasty (HRA) is a preferred surgical procedure among hip arthroplasty performed in young patients. The aim of this study is to show the long-term clinical and radiological results of HRA procedures performed for patients suffering from ONFH. METHODS Forty-five patients who underwent hip resurfacing with the diagnosis of femoral head osteonecrosis were included in the study. The Harris Hip Score (HHS) was used for clinical scoring of the patients. The blood chromium, cobalt, white blood cell (WBC) count, and CRP levels of patients were checked. Ultrasonography (USG) was performed for all patients at mid-term control checked for pseudo-tumours. For the radiological evaluation, acetabular inclination, stem shaft angle, prothesis-to-neck ratio, osteolysis zones, and heterotopic ossification were used. RESULTS The mean age of the patients was 46.6 ± 9.3 years, and the mean follow-up period was 11.83 ± 2.9 years. The mean HHS was 90.3 ± 12.8 for final follow-up. The mean WBC value was 8.2 109/L, mean CRP value was 6.3 mg/L, mean chromium value was 4.9 µg/L, and mean cobalt value was 1.8 µg/L. Inclination changing 0.2°(p = 0.788), stem shaft angle changing 0.7°(p = 0.424), and neck-to-prosthesis ratio changing 0.01°(p = 0.075). No pseudo-tumours were detected in any patients in USG examination. CONCLUSION HRA provides long-term implant survival and excellent clinical outcomes for end-stage ONFH patients with low complication rates.
Collapse
Affiliation(s)
- Serhat Akçaalan
- Orthopedics and Traumatology Department, Ankara City Hospital, Ankara, Turkey.
| | - Mehmet Can Kengil
- Orthopedics and Traumatology Department, Ankara City Hospital, Ankara, Turkey
| | - Ceyhun Çağlar
- Orthopedics and Traumatology Department, Ankara Yıldırım Beyazıt University, Ankara, Turkey
| | - Mahmut Uğurlu
- Orthopedics and Traumatology Department, Ankara Yıldırım Beyazıt University, Ankara, Turkey
| |
Collapse
|
3
|
Freund SS, Thorn APJ, Puri A, Petersen MM, Baad-Hansen T. Elevated cobalt levels in metal-on-polyethylene knee megaprostheses: a prospective 1-year cohort study of 56 patients with hip and knee megaprostheses. Acta Orthop 2024; 95:174-179. [PMID: 38629902 PMCID: PMC11022749 DOI: 10.2340/17453674.2024.40502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Accepted: 03/13/2023] [Indexed: 04/19/2024] Open
Abstract
BACKGROUND AND PURPOSE Concerns have emerged regarding elevated levels of cobalt and chromium in patients with metal-on-metal megaprostheses. This prospective study aims to identify systemic cobalt and chromium levels in metal-on-polyethylene knee and hip megaprostheses and their associations with other factors. METHODS 56 patients underwent knee or hip megaprosthesis surgery at 2 sarcoma centers. Serum cobalt and chromium levels were measured preoperatively and thrice within the first year using inductively coupled plasma mass spectrometry. RESULTS A statistically significant difference in serum cobalt levels (1.4 ppb; 95% confidence interval [CI] 0.0-3.3) was observed 1 year after knee megaprosthesis surgery compared with preoperative levels. In contrast no difference in chromium levels was observed after 1 year compared with preoperative levels (0.05 ppb; CI 0.0-0.8). An association between younger age, higher eGFR, and increased cobalt levels was observed. No significant correlations were found between ion levels and resection length or the number of modular connections. CONCLUSION We found elevated serum ion levels in metal-on-polyethylene knee megaprostheses in contrast to metal-on-polyethylene hip megaprostheses. Furthermore, a positive correlation between cobalt and chromium levels, and between cobalt and eGFR was identified, along with a negative correlation between cobalt and age. This study highlights the importance of monitoring systemic cobalt and chromium levels in patients with megaprostheses.
Collapse
Affiliation(s)
| | - Andrea Pohly Jeppesen Thorn
- Musculoskeletal Tumor Section of the Department of Orthopedic Surgery, Rigshospitalet - University of Copenhagen, Denmark
| | - Ajay Puri
- Orthopedic Oncology, Tata Memorial Centre, HBNI, Mumbai, India
| | - Michael Mørk Petersen
- Musculoskeletal Tumor Section of the Department of Orthopedic Surgery, Rigshospitalet - University of Copenhagen, Denmark
| | | |
Collapse
|
4
|
Sarraj M, Hache P, Foroutan F, Oitment C, Marion TE, Guha D, Pahuta M. Natural history of degenerative cervical myelopathy: a meta-analysis and neurologic deterioration survival curve synthesis. Spine J 2024; 24:46-56. [PMID: 37549831 DOI: 10.1016/j.spinee.2023.07.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/19/2023] [Revised: 07/25/2023] [Accepted: 07/26/2023] [Indexed: 08/09/2023]
Abstract
BACKGROUND CONTEXT Cervical spine surgery is rapidly increasing, and our knowledge of the natural history of degenerative cervical myelopathy (DCM) is limited. PURPOSE To synthesize accurate time-based estimates of meaningful neurologic decline in patients with DCM managed conservatively and to provide formulae to help communicate survivorship estimates to patients. STUDY DESIGN Systematic review and meta-analysis. METHODS A systematic review and meta-analysis was conducted using Cochrane and PRISMA guidelines. A librarian-assisted search strategy using multiple databases with broad search terms and validated filter functions was used. All articles were reviewed in duplicate. RESULTS A total of 9570 studies were captured in the initial search, which after deletion of duplicates and manual review of abstracts and full texts revealed 6 studies for analyses. All studies were prospective cohorts or randomized controlled trials. The pooled survival estimates for neurologic stability (95% CrI) for mild DCM patients are: 91% (83%-97%) at one year; 85% (72%-94%) at 2 years; 84% (70%-94%) at 3 years; 75% (54%-90%) at 5 years; 66% (40%-86%) at 15 years; and 65% (39%-86%) at 20 years. The pooled survival estimates for neurologic stability (95% CrI) for moderate/severe DCM patients are: 83% (76%-89%) at 1 year; 72% (62%-81%) at 2 years; 71% (60%-80%) at 3 years; 55% (41%-68%) at 5 years; 44% (27%-59%) at 15 years; and 43% (25%-58%) at 20 years. CONCLUSIONS This is the first quantitative synthesis of the totality of published data on DCM natural history. Our review confirms a slow decline in neurologic function. We developed formulae which can be easily used by surgeons to communicate to patients their risk of neurologic deterioration. These formulae can be used to facilitate the shared decision-making process.
Collapse
Affiliation(s)
- Mohamed Sarraj
- McMaster University, Division of Orthopedic Surgery, Hamilton General Hospital, Hamilton, Ontario, Canada.
| | - Philip Hache
- McMaster University, Division of Orthopedic Surgery, Hamilton General Hospital, Hamilton, Ontario, Canada
| | - Farid Foroutan
- Ted Rogers Centre for Heart Research, University Health Network, Toronto, Ontario, Canada; Department of Health Research, Methods, Impact, McMaster University, Hamilton, Ontario, Canada
| | - Colby Oitment
- McMaster University, Division of Orthopedic Surgery, Hamilton General Hospital, Hamilton, Ontario, Canada
| | - Travis E Marion
- Department of Orthopaedic Surgery, Northern Ontario School of Medicine, Ontario, Canada
| | - Daipayan Guha
- McMaster University, Division of Neurosurgery, Hamilton General Hospital, Hamilton, Ontario, Canada
| | - Markian Pahuta
- McMaster University, Division of Orthopedic Surgery, Hamilton General Hospital, Hamilton, Ontario, Canada
| |
Collapse
|
5
|
Sarraj M, Hache P, Foroutan F, Oitment C, Marion TE, Guha D, Pahuta M. Long-Term Survivorship of Cervical Spine Procedures; A Survivorship Meta-Analysis and Meta-Regression. Global Spine J 2023; 13:840-854. [PMID: 36069054 DOI: 10.1177/21925682221125766] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
STUDY DESIGN Systematic Review. OBJECTIVES To conduct a meta-analysis on the survivorship of commonly performed cervical spine procedures to develop survival function curves for (i) second surgery at any cervical level, and (ii) adjacent level surgery. METHODS A systematic review of was conducted following PRISMA guidelines. Articles with cohorts of greater than 20 patients followed for a minimum of 36 months and with available survival data were included. Procedures included were anterior cervical discectomy and fusion (ACDF), cervical disc arthroplasty (ADR), laminoplasty (LAMP), and posterior laminectomy and fusion (PDIF). Reconstructed individual patient data were pooled across studies using parametric Bayesian survival meta-regression. RESULTS Of 1829 initial titles, 16 citations were included for analysis. 73 811 patients were included in the second surgery analysis and 2858 patients in the adjacent level surgery analysis. We fit a Log normal accelerated failure time model to the second surgery data and a Gompertz proportional hazards model to the adjacent level surgery data. Relative to ACDF, the risk of second surgery was higher with ADR and PDIF with acceleration factors 1.73 (95% CrI: 1.04, 2.80) and 1.35 (95% CrI: 1.25, 1.46) respectively. Relative to ACDF, the risk of second surgery was lower with LAMP with deceleration factor .06 (95% CrI: .05, .07). ADR decreased the risk of adjacent level surgery with hazard ratio .43 (95% CrI: .33, .55). CONCLUSIONS In cases of clinical equipoise between fusion procedures, our analysis suggests superior survivorship with anterior procedures. For all procedures, laminoplasty demonstrated superior survivorship.
Collapse
Affiliation(s)
- Mohamed Sarraj
- Division of Orthopedic Surgery, Hamilton General Hospital, 3710McMaster University, Hamilton, ON, Canada
| | - Philip Hache
- Division of Orthopedic Surgery, Hamilton General Hospital, 3710McMaster University, Hamilton, ON, Canada
| | - Farid Foroutan
- Ted Rogers Centre for Heart Research, 7989University Health Network, Toronto, ON, Canada
- Department of Health Research, Methods, Impact, 3710McMaster University, Hamilton, ON, Canada
| | - Colby Oitment
- Division of Orthopedic Surgery, Hamilton General Hospital, 3710McMaster University, Hamilton, ON, Canada
| | - Travis E Marion
- Department of Orthopaedic Surgery, 26627Northern Ontario School of Medicine, Thunder Bay, ON, Canada
| | - Daipayan Guha
- Division of Neurosurgery, Hamilton General Hospital, 3710McMaster University, Hamilton, ON, Canada
| | - Markian Pahuta
- Division of Orthopedic Surgery, Hamilton General Hospital, 3710McMaster University, Hamilton, ON, Canada
| |
Collapse
|
6
|
Chang JS, Haddad FS. Revision total hip arthroplasty for metal-on-metal failure. J Clin Orthop Trauma 2020; 11:9-15. [PMID: 32001977 PMCID: PMC6985013 DOI: 10.1016/j.jcot.2019.09.021] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2019] [Accepted: 09/26/2019] [Indexed: 12/12/2022] Open
Abstract
Metal-on-metal (MoM) arthroplasty systems became popular in the early-2000s due to presumed advantages of improved wear characteristics and superior stability. However, subsequent reports of abnormal soft-tissue reactions to MoM implants and national registry data reporting high failure rates raised concerns. Early outcomes of revision total hip arthroplasty (THA) for adverse reaction to metal debris (ARMD) were poor, leading to development of surveillance programs and a trend towards early revision surgery. Patients with MoM arthroplasties require surveillance, comprehensive history and physical examination, imaging with ultrasound or magnetic resonance imaging (MRI), and laboratory evaluation including metal ion levels. Operative strategies for revision THA vary from exchange of modular components to extensive debridement and reconstruction with revision components. Surgeons should be aware of the increased risks of dislocation and infection following revision THA for ARMD. However, there is growing evidence that early revision surgery prior to extensive soft tissue destruction results in improved outcomes and decreased re-operation rates. It is estimated that >1 million MoM articulations have been implanted, with a large proportion still in situ. It is imperative to understand the aetiology, presentation, and management strategies for these patients to optimise their clinical outcomes.
Collapse
Affiliation(s)
- Justin S. Chang
- Department of Trauma and Orthopaedic Surgery, University College London Hospitals, 250 Euston Road, NW1 2PG, London, UK,Corresponding author.
| | - Fares S. Haddad
- Department of Trauma and Orthopaedic Surgery, University College London Hospitals, 250 Euston Road, NW1 2PG, London, UK,The Princess Grace Hospital, 42-52 Nottingham Place, W1U 5NY, London, UK
| |
Collapse
|
7
|
Juneau D, Grammatopoulos G, Alzahrani A, Thornhill R, Inacio JR, Dick A, Vogel KI, Dobransky J, Beaulé PE, Dwivedi G. Is end-organ surveillance necessary in patients with well-functioning metal-on-metal hip resurfacings? Bone Joint J 2019; 101-B:540-546. [DOI: 10.1302/0301-620x.101b5.bjj-2018-1478.r1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Aims Cardiac magnetic resonance (CMR) was used to assess whether cardiac function or tissue composition was affected in patients with well-functioning metal-on-metal hip resurfacing arthroplasties (MoMHRA) when compared with a group of controls, and to assess if metal ion levels correlated with any of the functional or structural parameters studied. Patients and Methods In all, 30 participants with no significant cardiac history were enrolled: 20 patients with well-functioning MoMHRA at mean follow-up of 8.3 years post-procedure (ten unilateral, ten bilateral; 17 men, three women) and a case-matched control group of ten non-MoM total hip arthroplasty patients (six men, four women). The mean age of the whole cohort (study group and controls) at the time of surgery was 50.6 years (41.0 to 64.0). Serum levels of cobalt and chromium were measured, and all patients underwent CMR imaging, including cine, T2* measurements, T1 and T2 mapping, late gadolinium enhancement, and strain measurements. Results None of the MoMHRA patients showed clinically significant cardiac functional abnormality. The MoMHRA patients had larger indexed right and left end diastolic volumes (left ventricular (LV): 74 ml/m2 vs 67 ml/m2, p = 0.045; right ventricular: 80 ml/m2 vs 71 ml/m2, p = 0.02). There was a small decrease in T2 time in the MoMHRA patients (median 49 ms vs 54 ms; p = 0.0003). Higher metal ion levels were associated with larger LV volumes and with shorter T2 time. Conclusion Although cardiac function is not clinically adversely affected in patients with well-functioning MoMHRA, modern imaging is able to demonstrate subtle changes in structure and function of the heart. As these changes correlate with systemic ion measurements, they may be consequences of wear debris deposition. Longer, longitudinal studies are necessary to determine whether cardiac function will become affected. Cite this article: Bone Joint J 2019;101-B:540–546.
Collapse
Affiliation(s)
- D. Juneau
- Department of Radiology and Nuclear Medicine, Centre Hospitalier de l’Université de Montréal (CHUM), Montréal, Canada
- University of Ottawa Heart Institute, Division of Cardiology, Department of Medicine, Ottawa, Canada
| | - G. Grammatopoulos
- Division of Orthopaedic Surgery, University of Ottawa Faculty of Medicine, The Ottawa Hospital, Ottawa, Canada
| | - A. Alzahrani
- King Saud bin Abdulaziz University for Health Sciences, King Faisal Cardiac Center, Jeddah, Saudi Arabia
| | - R. Thornhill
- The Ottawa Hospital, Department of Medical Imaging, Ottawa, Canada
| | - J. R. Inacio
- The Ottawa Hospital, Department of Medical Imaging, Ottawa, Canada
| | - A. Dick
- University of Ottawa Heart Institute, Division of Cardiology, Department of Medicine, Ottawa, Canada
| | - K. I. Vogel
- Division of Orthopaedic Surgery, University of Ottawa Faculty of Medicine, The Ottawa Hospital, Ottawa, Canada
| | - J. Dobransky
- Division of Orthopaedic Surgery, University of Ottawa Faculty of Medicine, The Ottawa Hospital, Ottawa, Canada
| | - P. E. Beaulé
- Division of Orthopaedic Surgery, University of Ottawa Faculty of Medicine, The Ottawa Hospital, Ottawa, Canada
- University of Ottawa, Ottawa, Canada
| | - G. Dwivedi
- University of Ottawa Heart Institute, Division of Cardiology, Department of Medicine, Ottawa, Canada
- Consultant in Cardiology and Professor of Cardiology, The University of Western Australia, Harry Perkins Institute of Medical Research and Fiona Stanley Hospital, Perth, Australia
| |
Collapse
|
8
|
Hernández-Vaquero D, García-Pascual M, Iglesias-Fernández S, Escandon-Rodríguez A. Metal-on-metal surface hip arthroplasties. Is annual monitoring of blood metal levels necessary? Rev Esp Cir Ortop Traumatol (Engl Ed) 2018. [DOI: 10.1016/j.recote.2018.03.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022] Open
|
9
|
Lison D, van den Brule S, Van Maele-Fabry G. Cobalt and its compounds: update on genotoxic and carcinogenic activities. Crit Rev Toxicol 2018; 48:522-539. [PMID: 30203727 DOI: 10.1080/10408444.2018.1491023] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
This article summarizes recent experimental and epidemiological data on the genotoxic and carcinogenic activities of cobalt compounds. Emphasis is on the respiratory system, but endogenous exposure from Co-containing alloys used in endoprostheses, and limited data on nanomaterials and oral exposures are also considered. Two groups of cobalt compounds are differentiated on the basis of their mechanisms of toxicity: (1) those essentially involving the solubilization of Co(II) ions, and (2) metallic materials for which both surface corrosion and release of Co(II) ions act in concert. For both groups, identified genotoxic and carcinogenic mechanisms are non-stochastic and thus expected to exhibit a threshold. Cobalt compounds should, therefore, be considered as genotoxic carcinogens with a practical threshold. Accumulating evidence indicates that chronic inhalation of cobalt compounds can induce respiratory tumors locally. No evidence of systemic carcinogenicity upon inhalation, oral or endogenous exposure is available. The scarce data available for Co-based nanosized materials does not allow deriving a specific mode of action or assessment for these species.
Collapse
Affiliation(s)
- D Lison
- Louvain Centre for Toxicology and Applied Pharmacology (LTAP), Catholic University of Louvain, Brussels, Belgium
| | - S van den Brule
- Louvain Centre for Toxicology and Applied Pharmacology (LTAP), Catholic University of Louvain, Brussels, Belgium
| | - G Van Maele-Fabry
- Louvain Centre for Toxicology and Applied Pharmacology (LTAP), Catholic University of Louvain, Brussels, Belgium
| |
Collapse
|
10
|
Hernández-Vaquero D, García-Pascual M, Iglesias-Fernández S, Escandon-Rodríguez A. Metal-on-metal surface hip arthroplasties. Is annual monitoring of blood metal levels necessary? Rev Esp Cir Ortop Traumatol (Engl Ed) 2018; 62:436-441. [PMID: 29884514 DOI: 10.1016/j.recot.2018.03.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2017] [Revised: 02/19/2018] [Accepted: 03/13/2018] [Indexed: 11/27/2022] Open
Abstract
INTRODUCTION Blood cobalt (Co) and chromium (Cr) ion levels have been used as surveillance tools for adverse reaction to metal debris in metal-on-metal (MoM) hip arthroplasty. The aim of our study was to present serial 7-13 year blood Co and Cr levels in a cohort of MoM total hip arthroplasties in asymptomatic patients. MATERIAL AND METHODS A total of 52 MoM surface total hip arthroplasties were included in this study with data collected prospectively. Annual follow-up with blood Co and Cr measurements was performed. Revision surgery was necessary for 16 patients and therefore they dropped out of the study. The metal ion levels were analyzed separately in 31 asymptomatic patients. RESULTS High Cr or Co levels were not found continuously in any of the asymptomatic patients. The median Cr in blood was maintained between 1.3 and 5.4μg/L and that of Co between 0.5 and 1.2μg/L. After 7 years, there was no significant change in Co and Cr values. CONCLUSION In the medium term and in asymptomatic patients, the metallic blood levels remained unchanged; therefore, it does not seem appropriate to repeat these tests on a permanent basis in annual controls.
Collapse
Affiliation(s)
- D Hernández-Vaquero
- Departamento de Cirugía, Facultad de Medicina, Universidad de Oviedo, Oviedo, España; Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario San Agustín, Avilés, España.
| | - M García-Pascual
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario San Agustín, Avilés, España
| | - S Iglesias-Fernández
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario San Agustín, Avilés, España
| | - A Escandon-Rodríguez
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario San Agustín, Avilés, España
| |
Collapse
|
11
|
Granchi D, Savarino LM, Ciapetti G, Baldini N. Biological effects of metal degradation in hip arthroplasties. Crit Rev Toxicol 2017; 48:170-193. [PMID: 29130357 DOI: 10.1080/10408444.2017.1392927] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Metals and metal alloys are the most used materials in orthopedic implants. The focus is on total hip arthroplasty (THA) that, though well tolerated, may be associated with local and remote adverse effects in the medium-long term. This review aims to summarize data on the biological consequences of the metal implant degradation that have been attributed predominantly to metal-on-metal (MoM) THA. Local responses to metals consist of a broad clinical spectrum ranging from small asymptomatic tissue lesions to severe destruction of bone and soft tissues, which are designated as metallosis, adverse reactions to metal debris (ARMD), aseptic lymphocytic vasculitis associated lesion (ALVAL), and pseudotumors. In addition, the dissemination of metal particles and ions throughout the body has been associated with systemic adverse effects, including organ toxicity, cancerogenesis, teratogenicity, and immunotoxicity. As proved by the multitude of studies in this field, metal degradation may increase safety issues associated with THA, especially with MoM hip systems. Data collection regarding local, systemic and long-term effects plays an essential role to better define any safety risks and to generate scientifically based recommendations.
Collapse
Affiliation(s)
- Donatella Granchi
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Lucia Maria Savarino
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Gabriela Ciapetti
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Nicola Baldini
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy.,b Department of Biomedical and Neuromotor Science , University of Bologna , Bologna , Italy
| |
Collapse
|
12
|
Campbell P, Ebramzadeh E. ARMD and Presumed Dangerous!: Commentary on an article by Gulraj S. Matharu, BSc(Hons), MRCS, MRes, et al.: "Blood Metal Ion Thresholds to Identify Patients with Metal-on-Metal Hip Implants at Risk of Adverse Reactions to Metal Debris. An External Multicenter Validation Study of Birmingham Hip Resurfacing and Corail-Pinnacle Implants". J Bone Joint Surg Am 2017; 99:e100. [PMID: 28926394 DOI: 10.2106/jbjs.17.00701] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
13
|
Laitinen M, Nieminen J, Reito A, Pakarinen TK, Suomalainen P, Pamilo K, Parkkinen J, Lont T, Eskelinen A. High blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements. Acta Orthop 2017; 88:269-274. [PMID: 28122467 PMCID: PMC5434594 DOI: 10.1080/17453674.2017.1283846] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - There has been increasing alarm regarding metal-on-metal (MoM) joint replacements leading to elevated levels of metal ions and adverse reactions to metal debris (ARMDs). There is little information available concerning the prevalence of and risk factors for these adverse reactions, except with MoM hip joint replacements. We determined the levels of metal ions in blood and the rate of revision due to ARMDs in patients treated with MoM hinge total knee arthroplasty (TKA). Patients and methods - 22 patients with TKAs and MoM hinge connecting mechanisms were studied for whole-blood chromium and cobalt levels at 6 months, 1 year, and/or ≥2 years after surgery. Possible ARMDs were investigated by MRI. 12 patients with TKAs and metal-on-polyethylene (MoP) connecting mechanisms served as controls. Results - The cobalt levels were over 5 ppb in 19 of the 22 patients in the MoM group and in 1 of the 12 patients in the MoP group. The chromium levels were over 5 ppb in 11 of the 22 patients in the MoM group and in none of the 12 patients in the MoP group. Pseudotumors were operated in 4 of the 22 patients in the MoM group and in none of the patients in the MoP group. Interpretation - Our results clearly show that the MoM hinge TKA carries a high risk of increased levels of systemic metal ions and also local ARMD, leading to complicated knee revisions. We therefore discourage the use of MoM hinge TKA.
Collapse
Affiliation(s)
- Minna Laitinen
- Department of Orthopedics, Musculoskeletal Surgery Unit, Tampere University Hospital;,Coxa Hospital for Joint Replacement, Tampere;,Correspondence:
| | | | - Aleksi Reito
- Department of Orthopedics, Central Finland Central Hospital, Jyväskylä
| | - Toni-Karri Pakarinen
- Department of Orthopedics, Musculoskeletal Surgery Unit, Tampere University Hospital;,Coxa Hospital for Joint Replacement, Tampere
| | - Piia Suomalainen
- Department of Orthopedics, Musculoskeletal Surgery Unit, Tampere University Hospital
| | - Konsta Pamilo
- Department of Orthopedics, Central Finland Central Hospital, Jyväskylä
| | | | - Tonis Lont
- Coxa Hospital for Joint Replacement, Tampere
| | | |
Collapse
|
14
|
Cadossi M, Terrando S, Sambri A, Tedesco G, Mazzotti A, Bordini B, De Pasquale D, Faldini C. What should I expect from my recalled Adept Hip Resurfacing? Musculoskelet Surg 2017; 101:249-254. [PMID: 28452042 DOI: 10.1007/s12306-017-0476-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2017] [Accepted: 04/17/2017] [Indexed: 12/12/2022]
Abstract
"My Hip Resurfacing (HR) has been recalled. What will happen to me?" This is the question of every patient who underwent an implant recall, a highly stressful event for both patients and physicians. Triggered by a 11.64% failure rate at 7 years, a recall process started for Adept HR with head diameter less than 48 mm. We report our experience in the recall process of 40 patients with the above-mentioned components. One patient underwent revision surgery due to an adverse reaction to metal debris at 5-year follow-up. None of the patients were scheduled for revision, with an estimated survival rate of 97.6% at 7 years. Implants were well positioned with an average acetabular inclination angle of 37°. Cobalt and chromium blood levels were below the safety threshold of clinical relevance. Functional scores were excellent. In the case of a well-positioned device with normal ion levels, a good performance of the implant is generally observed. Even if we experienced a very low revision rate, this may certainly get worse over time since not all possible failures are predictable, thus requiring a careful periodic follow-up.
Collapse
Affiliation(s)
- Matteo Cadossi
- Orthopaedic Department, Istituto Ortopedico Rizzoli, via Pupilli 1, 40136, Bologna, Italy
| | - Silvio Terrando
- Orthopaedic Department, Istituto Ortopedico Rizzoli, via Pupilli 1, 40136, Bologna, Italy.
| | - Andrea Sambri
- Orthopaedic Department, Istituto Ortopedico Rizzoli, via Pupilli 1, 40136, Bologna, Italy
| | - Giuseppe Tedesco
- Orthopaedic Department, Istituto Ortopedico Rizzoli, via Pupilli 1, 40136, Bologna, Italy
| | - Antonio Mazzotti
- Orthopaedic Department, Istituto Ortopedico Rizzoli, via Pupilli 1, 40136, Bologna, Italy
| | - Barbara Bordini
- Medical Technology Lab, Istituto Ortopedico Rizzoli, Bologna, Italy
| | | | - Cesare Faldini
- Orthopaedic Department, Istituto Ortopedico Rizzoli, via Pupilli 1, 40136, Bologna, Italy
| |
Collapse
|
15
|
Haddad FS. A positive end to 2016. Bone Joint J 2016; 98-B:1569-1570. [PMID: 27909115 DOI: 10.1302/0301-620x.98b12.38083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2016] [Accepted: 10/31/2016] [Indexed: 11/05/2022]
Affiliation(s)
- F S Haddad
- The Bone & Joint Journal, 22 Buckingham Street, London, WC2N 6ET and NIHR University College London Hospitals Biomedical Research Centre, UK
| |
Collapse
|