1
|
Comba LC, Gagliardi L, Onorato F, Rivera F. Periprosthetic Hip Fractures around the Stem: Can the Stem Design Affect Fracture Features? J Clin Med 2024; 13:2627. [PMID: 38731155 PMCID: PMC11084834 DOI: 10.3390/jcm13092627] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Revised: 03/21/2024] [Accepted: 04/28/2024] [Indexed: 05/13/2024] Open
Abstract
Background: Total hip arthroplasty is one of the most successful orthopedic surgeries; nevertheless, many of these surgeries are the causes of failure, and among them, periprosthetic fractures are one of the major causes of revision. Our study focuses on periprosthetic hip fractures with two different stem designs. The aim of the study was to analyze the obtained results, focusing on the features of periprosthetic stem fractures observed. Methods: We retrospectively reviewed periprosthetic fractures occurring between 2010 and 2023, involving Alloclassic® or CLS® uncemented femoral stems. We analyzed demographic data, proximal femur morphology, and the fracture type. Results: We identified 97 patients. Considering the proximal femur morphology, we found that there was statistically significant prevalence of Dorr A proximal femur morphology in the CLS® group and of Dorr C in the Alloclassic® group. Considering the distribution of the fracture pattern, we reported a non-statistically significant prevalence of the fracture pattern with stable stems in the CLS® group. Conclusions: The choice of the prosthetic design of the femoral stem is a crucial element when planning total hip arthroplasty. However, we found a non-statistically significant difference between the two stems considered, raising questions about the real role of stem design as a primary determinant of periprosthetic hip fractures.
Collapse
Affiliation(s)
- Luca Costanzo Comba
- Orthopedics and Trauma Department, SS Annunziata Hospital, ASL CN1, 12038 Savigliano, Italy
| | - Luca Gagliardi
- Orthopedics and Trauma Department, Univertità degli Studi di Torino, 10100 Turin, Italy
| | - Francesco Onorato
- Orthopedics and Trauma Department, Univertità degli Studi di Torino, 10100 Turin, Italy
| | - Fabrizio Rivera
- Orthopedics and Trauma Department, SS Annunziata Hospital, ASL CN1, 12038 Savigliano, Italy
| |
Collapse
|
2
|
Moret CS, Masri SE, Schelker BL, Friederich NF, Hirschmann MT. Unexpected early loosening of rectangular straight femoral Zweymüller stems with an alumina-reduced surface after total hip arthroplasty-a prospective, double-blind, randomized controlled trial. J Orthop Traumatol 2024; 25:12. [PMID: 38430413 PMCID: PMC10908941 DOI: 10.1186/s10195-023-00743-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2023] [Accepted: 12/27/2023] [Indexed: 03/03/2024] Open
Abstract
BACKGROUND Alumina particles from the grit blasting of Ti-alloy stems are suspected to contribute to aseptic loosening. An alumina-reduced stem surface was hypothesized to improve osseointegration and show comparable short-term outcomes to those of a standard stem. METHODS In this prospective, double-blind, randomized trial, 26 standard (STD) and 27 experimental new technology (NT) stems were implanted. The latter were additionally treated by acid etching and ice blasting to remove alumina particles from the grit-blasting process. Follow-up occurred at 12 and 24 months. Bone mineral density (BMD) around the stem was measured by a dual-energy x-ray absorptiometry device (DEXA). Radiographs were reviewed for alterations. Clinical scoring comprised the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and the Harris Hip Score (HHS). Survival rates were calculated up to 50 months. RESULTS Lower mean BMD and more severe cortical hypertrophies were found in the NT group. At 12 months, radiolucent lines were observed mostly in the metaphyseal zone for both groups, with a progression tendency in the NT group at 24 months. At 12 months, pain scores and the WOMAC total and physical activity scores were significantly lower in the NT group, without any differences thereafter. The number of NT stem revisions amounted to 6 (24%) and 11 (41%) at 24 and 50 months, respectively. CONCLUSION In the NT group, unexpected catastrophic failure rates of 41% caused by early aseptic loosening were noted within 50 months. Compared with the STD stems, NT stems lead to poor clinical and radiographic results. LEVEL OF EVIDENCE II. TRIAL REGISTRATION NCT05053048.
Collapse
Affiliation(s)
- Céline S Moret
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland, CH-4101, Bruderholz, Switzerland.
| | - Salim El Masri
- Department of Orthopaedic Surgery and Traumatology, Rhön Klinikum Campus, 97616, Bad Neustadt an Der Saale, Germany
| | - Benjamin L Schelker
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland, CH-4101, Bruderholz, Switzerland
| | - Niklaus F Friederich
- Department of Orthopaedic Surgery and Traumatology, University Hospital Basel, Basel, Switzerland
| | - Michael T Hirschmann
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland, CH-4101, Bruderholz, Switzerland
| |
Collapse
|
3
|
Shichman I, Lawrence KW, Berzolla E, Hernandez CS, Man-El R, Warschawski Y, Snir N, Schwarzkopf R, Hepinstall MS. Comparison of canal fill and radiolucent line formation between two fully coated, hydroxyapatite tapered stems: a 2-year follow-up after total hip arthroplasty. Arch Orthop Trauma Surg 2023; 143:6945-6954. [PMID: 37428271 DOI: 10.1007/s00402-023-04944-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Accepted: 06/04/2023] [Indexed: 07/11/2023]
Abstract
INTRODUCTION Comparison between fully hydroxyapatite (HA)-coated stems with differing geometry are lacking in the total hip arthroplasty (THA) literature. This study aimed to compare femoral canal fill, radiolucency formation, and 2-year implant survivorship between two commonly used, HA-coated stems. METHODS All primary THAs performed with two fully HA-coated stems (Polar stem, Smith&Nephew, Memphis, TN and Corail stem, DePuy-Synthes, Warsaw, IN) with a minimum 2-year radiographic follow-up were identified. Radiographic measures of proximal femoral morphology based on the Dorr classification and femoral canal fill were analyzed. Radiolucent lines were identified by Gruen zone. Perioperative characteristics and 2-year survivorship were compared between stem types. RESULTS A total of 233 patients were identified with 132 (56.7%) receiving the Polar stem (P) and 101 (43.3%) receiving the Corail stem (C). No differences were observed with respect to proximal femoral morphology. Femoral stem canal fill at the middle third of the stem was greater for P stem patients than for C stem patients (P stem; 0.80 ± 0.08 vs. C stem; 0.77 ± 0.08, p = 0.002), while femoral stem canal fill at the distal third of the stem and presence of subsidence were comparable between groups. A total of six and nine radiolucencies were observed in P stem and C stem patients, respectively. Revision rate at 2-year (P stem; 1.5% vs C stem; 0.0%, p = 0.51) and latest follow-up (P stem; 1.5% vs C stem; 1.0%, p = 0.72) did not differ between groups. CONCLUSION Greater canal fill at the middle third of the stem was observed for the P stem compared to the C stem, however, both stems demonstrated robust and comparable freedom from revision at 2-year and latest follow-up, with low incidences of radiolucent line formation. Mid-term clinical and radiographic outcomes for these commonly used, fully HA-coated stems remain equally promising in THA despite variations in canal fill.
Collapse
Affiliation(s)
- Ittai Shichman
- Department of Orthopedic Surgery, Orthopedic Hospital, NYU Langone Health, 301 East 17Th Street, 14Th Floor Suite 1402, New York, NY, 10003, USA.
- Division of Orthopedic Surgery, Sourasky Medical Center, Sackler School of Medicine, Tel- Aviv, Israel.
| | - Kyle W Lawrence
- Department of Orthopedic Surgery, Orthopedic Hospital, NYU Langone Health, 301 East 17Th Street, 14Th Floor Suite 1402, New York, NY, 10003, USA
| | - Emily Berzolla
- Department of Orthopedic Surgery, Orthopedic Hospital, NYU Langone Health, 301 East 17Th Street, 14Th Floor Suite 1402, New York, NY, 10003, USA
| | - Carlos Sandoval Hernandez
- Department of Orthopedic Surgery, Orthopedic Hospital, NYU Langone Health, 301 East 17Th Street, 14Th Floor Suite 1402, New York, NY, 10003, USA
| | - Rani Man-El
- Division of Orthopedic Surgery, Sourasky Medical Center, Sackler School of Medicine, Tel- Aviv, Israel
| | - Yaniv Warschawski
- Division of Orthopedic Surgery, Sourasky Medical Center, Sackler School of Medicine, Tel- Aviv, Israel
| | - Nimrod Snir
- Division of Orthopedic Surgery, Sourasky Medical Center, Sackler School of Medicine, Tel- Aviv, Israel
| | - Ran Schwarzkopf
- Department of Orthopedic Surgery, Orthopedic Hospital, NYU Langone Health, 301 East 17Th Street, 14Th Floor Suite 1402, New York, NY, 10003, USA
| | - Matthew S Hepinstall
- Department of Orthopedic Surgery, Orthopedic Hospital, NYU Langone Health, 301 East 17Th Street, 14Th Floor Suite 1402, New York, NY, 10003, USA
| |
Collapse
|
4
|
Davey MS, Doyle TR, Murphy E, Fenelon C, Murphy CG, Cassar-Gheiti AJ. Battle of the titans: Survivorship analysis of the 3 most common types of uncemented femoral stems used across national registries. J Orthop 2023; 43:41-47. [PMID: 37564704 PMCID: PMC10409998 DOI: 10.1016/j.jor.2023.07.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Accepted: 07/16/2023] [Indexed: 08/12/2023] Open
Abstract
Background Although many institutions utilize uncemented stems as routine in performing total hip arthroplasty (THA), many surgeons continue to rely on outcomes reported in the literature in the form of small cohorts and patient series when analyzing survivorship for specific implants. The purpose of this study was to identify and analyze the survivorship of the 3 most common uncemented stem types (as opposed to brands) used across multiple national joint registries. Methods A review of data available from all national joint registries was carried out in July 2022. Analysis of each individual registry and classified uncemented implants into the seven different uncemented stem types. The 3 most common stem types were identified, and average cumulative revision rates calculated. Metal on metal bearings surface implants were excluded from this study due to high revision rates across all implant types. Results Our detailed review identified 6 out of 13 (NJR, AOANJRR, LROI, EPRD, MARCQI and the NZJR) international registries reporting implant specific survivorship on uncemented femoral stems; including 960,328 uncemented stems across all registries. The most common type of stem used was type 3c, accounting for 61% (583,724), followed by type 1 stems with 23% (217,897) and type 2 stems with 8% (79,257). Cumulative revision rates at 13 years follow-up for these stems ranged from 6.9% to 7.9%. Conclusion Although all stem types have comparable revision rates across all registries, the most common uncemented stem reported was the type 3c, tapered rectangular fully coated stem. Furthermore, out of all type 3c, the Müller design philosophy with full hydroxyapatite coating seems to be the most sought after worldwide. In this study we can conclude, thus far, that there does not appear to clinical or statistical differences in revision rates between the different stem types. Level of evidence III.
Collapse
Affiliation(s)
- Martin S. Davey
- Royal College of Surgeons in Ireland, Dublin, Ireland
- Galway University Hospitals, Galway, Ireland
| | | | - Evelyn Murphy
- Royal College of Surgeons in Ireland, Dublin, Ireland
| | | | - Colin G. Murphy
- Galway University Hospitals, Galway, Ireland
- University of Galway, Galway, Ireland
| | | |
Collapse
|
5
|
Blum P, Neugebauer J, Keiler A, Putzer D, Watrinet J, Biermeier S, Dammerer D. Mid-Term Migration Behavior of an Uncemented Proximally Anchored Straight Stem-A Retrospective EBRA Migration Analysis. J Clin Med 2023; 12:4335. [PMID: 37445370 DOI: 10.3390/jcm12134335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 06/17/2023] [Accepted: 06/23/2023] [Indexed: 07/15/2023] Open
Abstract
BACKGROUND Aseptic loosening is one of the most-common causes of the failure of cementless stems. Einzel Bild Röntgen Analyse-Femoral Component Analysis (EBRA-FCA) allows the diagnosis of stem migration, which can be considered a factor in predicting implant survival. The current study aimed to present the migration behavior of a tapered proximally anchored straight stem. METHODS This retrospective study reviewed all consecutive patients who received a cementless CBC straight stem (Mathys AG, Bettlach, Switzerland) between 2005 and 2019. We analyzed the migration pattern using the EBRA-FCA software and reviewed their medical histories. In addition, periprosthetic radiolucency was rated according to the Gruen zones and femoral configuration according to Dorr. RESULTS A total of 333 stems in 332 patients (female 191; male 141) met our inclusion criteria. The mean age at surgery was 63 (range 21-87) years. Migration analysis by EBRA-FCA showed a mean subsidence of 1.6 mm at final follow-up at 96 months with a maximum noted mean subsidence of 2.0 mm at 72 and 84 months. Dorr Type A showed a tendency of less subsidence than did Dorr Type B and was statistically significant at 6 (p = 0.0396) and 72 months (p = 0.0127). The body mass index (BMI) and increased subsidence were not found to correlate (p > 0.05). For this cohort, the overall femoral revision-free rate was 95.2% and the revision-free rate for aseptic loosening was 99.1%. CONCLUSIONS The results showed migration behavior in cementless stems with initial increased migration and subsequent secondary stabilization, suggesting an excellent long-term outcome. Stem migration of this tapered proximally anchored stem might be lower in Dorr Type A than in Dorr Type B femurs without being statistically significant at all time points.
Collapse
Affiliation(s)
- Philipp Blum
- Department of Trauma Surgery, BG Trauma Center Murnau, 82418 Murnau, Germany
| | - Johannes Neugebauer
- Department of Orthopaedics and Traumatology, Krems University Hospital, 3500 Krems, Austria
- Karl Landsteiner Private University for Health Sciences, 3500 Krems, Austria
| | - Alexander Keiler
- Department of Orthopaedics and Traumatology, Medical University of Innsbruck, 6020 Innsbruck, Austria
| | - David Putzer
- Department of Experimental Orthopaedics, Medical University of Innsbruck, 6020 Innsbruck, Austria
| | - Julius Watrinet
- Department of Trauma Surgery, BG Trauma Center Murnau, 82418 Murnau, Germany
| | - Sebastian Biermeier
- Department of Orthopaedics and Traumatology, Medical University of Innsbruck, 6020 Innsbruck, Austria
| | - Dietmar Dammerer
- Department of Orthopaedics and Traumatology, Krems University Hospital, 3500 Krems, Austria
- Karl Landsteiner Private University for Health Sciences, 3500 Krems, Austria
| |
Collapse
|
6
|
Orita K, Goto K, Kuroda Y, Kawai T, Okuzu Y, Takaoka Y, Matsuda S. Long-term outcome of primary total hip arthroplasty with cementless bioactive glass ceramic bottom-coated implants and highly cross-linked polyethylene: A minimum 10-year analysis. J Orthop Sci 2023; 28:385-390. [PMID: 35058113 DOI: 10.1016/j.jos.2021.12.019] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Revised: 11/30/2021] [Accepted: 12/22/2021] [Indexed: 11/17/2022]
Abstract
BACKGROUND Cementless glass ceramics containing apatite and wollastonite (AW-GC) bottom-coated titanium hip implants were developed; early excellent clinical and radiographic results have been reported previously. This study aimed to investigate the long-term clinical and radiographic outcomes in detail, and the wear rate of HXLPE. METHODS We retrospectively evaluated 99 patients (117 hips) between November 2001 and December 2007. The survival rate was estimated using the Kaplan-Meier method. Hip joint function was evaluated using the Japanese Orthopaedic Association (JOA) score. The extent of radiographic signs was determined from the radiographs performed at the last follow-up. Polyethylene wear was measured using Martell's Hip Analysis Suite. We assessed the possible factors affecting the steady-state linear wear rate. RESULTS The mean follow-up period was 14.8 ± 2.1 (10-18.6) years. The mean JOA score improved to 88.7 ± 9.4 (59-100) at the final follow-up from 47.8 ± 12.5 (17-76) before surgery. The overall survival rate with the end point of all-cause revision and wear-related revision was 99% and 100% respectively. There was no osteolysis or loosening of either the acetabular or femoral component. All hips were classified as having bone ingrowth fixation. The mean steady-state wear rate was 0.008 ± 0.025 mm/year. We found no significant correlation between the wear rate and age, body weight, body mass index, cup inclination and femoral head size. CONCLUSION The combination of AW-GC bottom-coated implants and HXLPE showed excellent implant survival and wear resistance for 15 years.
Collapse
Affiliation(s)
- Kazuki Orita
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto, 606-8507, Japan.
| | - Koji Goto
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Yutaka Kuroda
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Toshiyuki Kawai
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Yaichiro Okuzu
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Yusuke Takaoka
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Shuichi Matsuda
- Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto, 606-8507, Japan
| |
Collapse
|
7
|
Shahin M, Massé V, Belzile É, Bédard L, Angers M, Vendittoli PA. Midterm results of titanium conical Wagner stem with challenging femoral anatomy: Survivorship and unique bone remodeling. Orthop Traumatol Surg Res 2023; 109:103242. [PMID: 35158103 DOI: 10.1016/j.otsr.2022.103242] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Revised: 08/04/2021] [Accepted: 08/31/2021] [Indexed: 02/07/2023]
Abstract
BACKGROUND Complex anatomy of the proximal femur makes total hip arthroplasty (THA) more challenging. Short, straight, fluted and conical titanium stem like the Wagner Cone can be helpful to address small femoral canal, increased femoral neck version, important leg length discrepancy or proximal femoral deformity. The outcome in these patients is less assured and associated with high rate of complications. Therefore, we did a retrospective study aiming to answer: 1) can the Wagner Cone stem provide acceptable mid- to long-term implant survivorship; 2) help minimizing perioperative adverse events; 3) produce favorable clinical outcome measured by WOMAC score; and 4) be associated with a favorable radiographic femoral bone remodeling at the last follow-up? HYPOTHESIS Wagner Cone stem is an advantageous solution for the distorted proximal femur in complex THA. PATIENTS AND METHOD Our cohort was derived from the patient registries where medical records of 88 patients (103 hips) who underwent primary THA using the Wagner prosthesis were retrospectively reviewed. Then, data was analyzed for patients' demographics and surgical data, and comparing preoperative, immediate postoperative and last follow-up data. Eleven patients (12 hips) were excluded (7 hips followed up less than 2 years or lost to follow-up, 3 hips that had the Wagner stem for revision and 2 Wagner stems inserted for periprosthetic fracture). This left 77 patients (91 hips) with Wagner cone stems implanted for more than 2 years between March 2003 and February 2017 by 7 surgeons in 3 academic hospitals. Implant revision, reoperations, WOMAC score and radiographic analyses were recorded at last follow-up. RESULTS After a mean follow-up of 7.8 (range, 2.0-16.2) years, Wagner stem survivorship was 98.9% (95% CI: 94 to 100%) with one (1.1%) stem revision for failure of osteointegration. Five (5.5%) acetabular revisions, one for aseptic loosening, 2 for adverse reaction to metal debris and 2 for infection. One (1.1%) sciatic neuropathy and 4 (4.4%) intraoperative fractures were encountered. The mean WOMAC score was 90.5±11.4 (59-100). Radiographic analysis showed clear signs of stem osseointegration and hypertrophic bone remodeling in 82 cases (92.1%). CONCLUSIONS Used in complex cases with proximal distorted femurs, the Wagner Cone stem demonstrated a low complication rate, a high-rate consistent adaptive bone remodeling, excellent clinical results, and midterm survival. It is a safe, reliable and advantageous option in complex primary THA. However, the contribution of the underlying cause of the secondary osteoarthritis on the long-term survival of the stem remains to be demonstrated. LEVEL OF EVIDENCE IV; retrospective study.
Collapse
Affiliation(s)
- Maged Shahin
- Surgery Department, Montreal University, Hôpital Maisonneuve-Rosemont, 5415, boulevard de l'Assomption, H1T 2M4 Montréal, Québec, Canada
| | - Vincent Massé
- Surgery Department, Montreal University, Hôpital Maisonneuve-Rosemont, 5415, boulevard de l'Assomption, H1T 2M4 Montréal, Québec, Canada; Clinique Orthopédique Duval, 1487, boulevard des Laurentides, H7M 2Y3 Laval, Québec, Canada
| | - Étienne Belzile
- Division of Orthopaedic Surgery, CHU de Québec, Université Laval, 1401 18(e), rue, Quebec, G1J 1Z4 QC, Canada; Personalized Arthroplasty Society, 3525, Piedmont road NE, Building 5 suite 300, 30305 Atlanta, GA, USA
| | - Luc Bédard
- Division of Orthopaedic Surgery, CHU de Québec, Université Laval, 1401 18(e), rue, Quebec, G1J 1Z4 QC, Canada
| | - Michèle Angers
- Division of Orthopaedic Surgery, CHU de Québec, Université Laval, 1401 18(e), rue, Quebec, G1J 1Z4 QC, Canada
| | - Pascal-André Vendittoli
- Surgery Department, Montreal University, Hôpital Maisonneuve-Rosemont, 5415, boulevard de l'Assomption, H1T 2M4 Montréal, Québec, Canada; Clinique Orthopédique Duval, 1487, boulevard des Laurentides, H7M 2Y3 Laval, Québec, Canada; Personalized Arthroplasty Society, 3525, Piedmont road NE, Building 5 suite 300, 30305 Atlanta, GA, USA.
| |
Collapse
|
8
|
Liu B, Wang H, Zhang M, Li J, Zhang N, Luan Y, Fang C, Cheng CK. Capability of auxetic femoral stems to reduce stress shielding after total hip arthroplasty. J Orthop Translat 2023; 38:220-228. [DOI: 10.1016/j.jot.2022.11.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Revised: 10/05/2022] [Accepted: 11/04/2022] [Indexed: 11/24/2022] Open
|
9
|
Kamel Shehata MEM, Mustapha K, Shehata E. Finite Element and Multivariate Random Forests Modelling for Stress Shield Attenuation in Customized Hip Implants. FORCES IN MECHANICS 2022. [DOI: 10.1016/j.finmec.2022.100151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
10
|
Ohyama Y, Minoda Y, Ohta Y, Sugama R, Takemura S, Nakamura H. A double tapered fully hydroxyapatite-coated stem has less contact area to femoral cortical bone than a tapered-wedge stem: a three-dimensional computed tomography-based density mapping analysis. Arch Orthop Trauma Surg 2022:10.1007/s00402-022-04655-3. [PMID: 36261646 DOI: 10.1007/s00402-022-04655-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Accepted: 10/09/2022] [Indexed: 11/02/2022]
Abstract
INTRODUCTION It is clinically important to analyze the initial contact state between an implant and femoral cortical bone as it affects clinical outcomes, such as stress shielding, stem subsidence, thigh pain, and patient-reported outcomes after total hip arthroplasty. Whether the initial contact state of a double-tapered fully hydroxyapatite (HA)-coated stem is achieved with the preserved cancellous or cortical bone remains to be established. This study aimed to compare the contact area with the femoral cortical bone between a double-tapered fully HA-coated stem (HA group) and a tapered wedge cementless stem (TW group) using three-dimensional computed tomography (3DCT)-based templating software. MATERIALS AND METHODS Forty-seven total hip arthroplasties in the HA and TW groups each were retrospectively analyzed. The contact area between the implant and femoral cortical bone in the whole stem and at each Gruen zone was measured using density mapping with 3DCT-based templating software. RESULTS The demographic data were not significantly different between the two groups. The contact area in the whole stem area was lower in the HA group (HA 5.4 ± 1.8% vs. TW 9.0 ± 4.8%, p < 0.01). The HA group had a lower contact area in zone 2 (HA 6.7 ± 6.5% vs. TW 15.6 ± 10.8%, p < 0.01) and zone 6 (HA 1.8 ± 3.5% vs. TW 6.3 ± 3.6%, p < 0.01) than the TW group. The implant type (β = 0.41, p < 0.01) and stem coronal alignment (β = - 0.29, p < 0.01) were significant predictors of the contact area in the whole stem area in a multiple regression analysis (adjusted R2 = 0.27, p < 0.01). CONCLUSION The contact area of the double-tapered fully HA-coated stem was significantly lower than that of the tapered wedge cementless stem.
Collapse
Affiliation(s)
- Yohei Ohyama
- Department of Orthopaedic Surgery, Osaka Metropolitan University Graduate School of Medicine, 1-4-3 Asahi-Machi Abeno-Ku Osaka-City, Osaka, 545-8585, Japan
| | - Yukihide Minoda
- Department of Orthopaedic Surgery, Osaka Metropolitan University Graduate School of Medicine, 1-4-3 Asahi-Machi Abeno-Ku Osaka-City, Osaka, 545-8585, Japan.
| | - Yoichi Ohta
- Department of Orthopaedic Surgery, Osaka Metropolitan University Graduate School of Medicine, 1-4-3 Asahi-Machi Abeno-Ku Osaka-City, Osaka, 545-8585, Japan
| | - Ryo Sugama
- Department of Orthopaedic Surgery, Osaka Metropolitan University Graduate School of Medicine, 1-4-3 Asahi-Machi Abeno-Ku Osaka-City, Osaka, 545-8585, Japan
| | - Susumu Takemura
- Department of Orthopedic Surgery, Osaka Rosai Hospital, 1179-3 Nagasone-Cho Sakai-City, Osaka, 591-8025, Japan
| | - Hiroaki Nakamura
- Department of Orthopaedic Surgery, Osaka Metropolitan University Graduate School of Medicine, 1-4-3 Asahi-Machi Abeno-Ku Osaka-City, Osaka, 545-8585, Japan
| |
Collapse
|
11
|
A Review of Biomaterials and Associated Performance Metrics Analysis in Pre-Clinical Finite Element Model and in Implementation Stages for Total Hip Implant System. Polymers (Basel) 2022; 14:polym14204308. [PMID: 36297885 PMCID: PMC9607025 DOI: 10.3390/polym14204308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 10/01/2022] [Accepted: 10/06/2022] [Indexed: 11/30/2022] Open
Abstract
Total hip replacement (THR) is a common orthopedic surgery technique that helps thousands of individuals to live normal lives each year. A hip replacement replaces the shattered cartilage and bone with an implant. Most hip implants fail after 10–15 years. The material selection for the total hip implant systems is a major research field since it affects the mechanical and clinical performance of it. Stress shielding due to excessive contact stress, implant dislocation due to a large deformation, aseptic implant loosening due to the particle propagation of wear debris, decreased bone remodeling density due to the stress shielding, and adverse tissue responses due to material wear debris all contribute to the failure of hip implants. Recent research shows that pre-clinical computational finite element analysis (FEA) can be used to estimate four mechanical performance parameters of hip implants which are connected with distinct biomaterials: von Mises stress and deformation, micromotion, wear estimates, and implant fatigue. In vitro, in vivo, and clinical stages are utilized to determine the hip implant biocompatibility and the unfavorable local tissue reactions to different biomaterials during the implementation phase. This research summarizes and analyses the performance of the different biomaterials that are employed in total hip implant systems in the pre-clinical stage using FEA, as well as their performances in in vitro, in vivo, and in clinical studies, which will help researchers in gaining a better understanding of the prospects and challenges in this field.
Collapse
|
12
|
Fujita M, Hayashi S, Hashimoto S, Kuroda Y, Kuroda R, Matsumoto T. The influence of stem alignment on the bone mineral density around the Polarstem following total hip arthroplasty. Arch Orthop Trauma Surg 2022; 143:3621-3627. [PMID: 36125537 DOI: 10.1007/s00402-022-04607-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Accepted: 08/29/2022] [Indexed: 12/01/2022]
Abstract
INTRODUCTION Bone mineral density is important in detecting implant loosening after total hip arthroplasty. The Polarstem can improve postoperative bone mineral density changes, but no information exists on the influence of postoperative stem alignment. Therefore, we investigated the relationship between bone mineral density change and stem alignment following total hip arthroplasty using a cementless Polarstem. MATERIALS AND METHODS This retrospective study included 42 patients (50 hips) who underwent total hip arthroplasty using a cementless Polarstem. Bone mineral density around the stem was measured according to the established Gruen zone classification using dual-energy X-ray absorptiometry. Measurements were performed 2 months postoperatively (baseline) and 6, 12, 18, and 24 months postoperatively. Bone mineral density changes at each follow-up were calculated as (bone mineral density at follow-up/at 2 weeks) × 100 (%). The stem varus, anterior tilt, and anteversion angles were measured using computed tomography. The correlation coefficient between bone mineral density changes and stem alignment were investigated. RESULTS The 24-month postoperative bone mineral density increased in zones 4 (106.0%) and 5 (107.3%) and decreased in zones 1 (89.6%) and 7 (90.6%). The mean stem varus angle, anterior tilt, and anteversion error were - 0.3° ± 1.8°, 1.9° ± 2.2°, and 6.8° ± 5.4°. Negative correlations were observed between the stem varus angle and 24-month postoperative bone mineral density change in zone 1 (r = - 0.34, p = 0.02), and the stem anteversion error and 24-month postoperative bone mineral density change in zone 1 (r = - 0.48, p < 0.01) and zone 7 (r = - 0.31, p = 0.03). CONCLUSIONS The cementless Polarstem may have a positive effect on postoperative bone mineral density in the distal femur. However, varus malalignment and anteversion error of the stem could have a negative influence on the bone mineral density changes in the proximal femur.
Collapse
Affiliation(s)
- Masahiro Fujita
- Department of Orthopedic Surgery, Kobe University Graduate School of Medicine, 7-5-1, Kusunoki-Cho, Chuo-Ku, Kobe, Hyogo, 650-0017, Japan
| | - Shinya Hayashi
- Department of Orthopedic Surgery, Kobe University Graduate School of Medicine, 7-5-1, Kusunoki-Cho, Chuo-Ku, Kobe, Hyogo, 650-0017, Japan.
| | - Shingo Hashimoto
- Department of Orthopedic Surgery, Kobe University Graduate School of Medicine, 7-5-1, Kusunoki-Cho, Chuo-Ku, Kobe, Hyogo, 650-0017, Japan
| | - Yuichi Kuroda
- Department of Orthopedic Surgery, Kobe University Graduate School of Medicine, 7-5-1, Kusunoki-Cho, Chuo-Ku, Kobe, Hyogo, 650-0017, Japan
| | - Ryosuke Kuroda
- Department of Orthopedic Surgery, Kobe University Graduate School of Medicine, 7-5-1, Kusunoki-Cho, Chuo-Ku, Kobe, Hyogo, 650-0017, Japan
| | - Tomoyuki Matsumoto
- Department of Orthopedic Surgery, Kobe University Graduate School of Medicine, 7-5-1, Kusunoki-Cho, Chuo-Ku, Kobe, Hyogo, 650-0017, Japan
| |
Collapse
|
13
|
Demographic Data Reliably Predicts Total Hip Arthroplasty Component Size. J Arthroplasty 2022; 37:S890-S894. [PMID: 35093541 DOI: 10.1016/j.arth.2022.01.051] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Revised: 01/10/2022] [Accepted: 01/20/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Preoperative radiographic templating for total hip arthroplasty (THA) has been shown to be inaccurate, although essential for streamlining operating room efficiency. Although demographic data have shown to predict total knee arthroplasty component sizes, the unique contour and design among femoral stem implants have limited a similar application for hip arthroplasty. The purpose of this study was to determine whether demographic data may predict cementless THA size independent of the stem design. METHODS A consecutive series of 1,653 index cementless metaphyseal-fitting THAs were reviewed between 2007 and 2019. This included 12 unique femoral component designs, 6 acetabular component designs, 60 femur size-design combinations, and 23 acetabular size-design combinations. Implanted component sizes and patient demographic data were collected, including gender, height, weight, laterality, age, race, and ethnicity. Multivariate linear regressions were formulated to predict implanted femur and acetabular component sizes from the demographic data. RESULTS There was a significant linear correlation between gender, implant model, age, height, and weight for femur (R2 = 0.778; P < .001) and acetabular (R2 = 0.491; P < .001) sizes. Calculated femur and acetabular component sizes averaged within 0.97 and 0.95 sizes of those implants, respectively. Femur and acetabular sizes were predicted within 1 size 79.1% and 78.2% and within 2 sizes 94.3% and 94.6% of the time, respectively. CONCLUSIONS Multivariate regression models were created based on specific demographics data to predict femur and acetabular component sizes. The model allows for simplified preoperative planning and potential cost savings implementation. A free phone application named EasyTJA was constructed for ease of implementation.
Collapse
|
14
|
Personalized Hip Joint Replacement with Large Diameter Head: Current Concepts. J Clin Med 2022; 11:jcm11071918. [PMID: 35407525 PMCID: PMC9000212 DOI: 10.3390/jcm11071918] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2022] [Revised: 03/20/2022] [Accepted: 03/25/2022] [Indexed: 02/05/2023] Open
Abstract
Hip arthroplasty is a common procedure in elective orthopaedic surgery that has excellent outcomes. Hip replacement surgery aims to create a “forgotten” joint, i.e., a pain-free joint akin to a native articulation. To achieve such goals, hip arthroplasty must be personalised. This is achieved by restoring: the centre of rotation of the native hip; leg length equality; femoral offset; femoral orientation; soft tissue tension; joint stability with an unrestricted hip range of motion; and having appropriate stress transfer to the bone. In addition, the whole pathway should provide an uneventful and swift postoperative recovery and lifetime implant survivorship with unrestricted activities. At our institution, the preferred option is a personalized total hip arthroplasty (THA) with a large diameter head (LDH) using either monobloc or dual-mobility configuration for the acetabular component. LDH THA offers an impingement-free range of motion and a reduced risk of dislocation. The larger head-neck offset allows for a supraphysiologic range of motion (ROM). This can compensate for a patient’s abnormal spinopelvic mobility and surgical imprecision. Additionally, LDH bearing with a small clearance exerts a high suction force, which provides greater hip micro-stability. With appropriate biomechanical reconstruction, LDH THA can restore normal gait parameters. This results in unrestricted activities and higher patient satisfaction scores. We use LDH ceramic on ceramic for our patients with a life expectancy of more than 20 years and use LDH dual mobility bearings for all others.
Collapse
|
15
|
Wang W, Xiong Y, Zhao R, Li X, Jia W. A novel hierarchical biofunctionalized 3D-printed porous Ti6Al4V scaffold with enhanced osteoporotic osseointegration through osteoimmunomodulation. J Nanobiotechnology 2022; 20:68. [PMID: 35123501 PMCID: PMC8817481 DOI: 10.1186/s12951-022-01277-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Accepted: 01/20/2022] [Indexed: 02/06/2023] Open
Abstract
Background Femoral stem of titanium alloy has been widely used for hip arthroplasty with considerable efficacy; however, the application of this implant in patients with osteoporosis is limited due to excessive bone resorption. Macrophages participate in the regulation of inflammatory response and have been a topic of increasing research interest in implant field. However, few study has explored the link between macrophage polarization and osteogenic–osteoclastic differentiation. The present study aims to develop a novel hierarchical biofunctionalized 3D-printed porous Ti6Al4V scaffold with enhanced osteoporotic osseointegration through immunotherapy. Method To improve the osteointegration under osteoporosis, we developed a hierarchical biofunctionalized 3D-printed porous Ti6Al4V scaffold (PT). Biomimetic extracellular matrix (ECM) was constructed inside the interconnected pores of PT in micro-scale. And in nano-scale, a drug cargo icariin@Mg-MOF-74 (ICA@MOF) was wrapped in ECM-like structure that can control release of icariin and Mg2+. Results In this novel hierarchical biofunctionalized 3D-printed porous Ti6Al4V scaffold, the macroporous structure provides mechanical support, the microporous structure facilitates cell adhesion and enhances biocompatibility, and the nanostructure plays a biological effect. We also demonstrate the formation of abundant new bone at peripheral and internal sites after intramedullary implantation of the biofunctionalized PT into the distal femur in osteoporotic rats. We further find that the controlled-release of icariin and Mg2+ from the biofunctionalized PT can significantly improve the polarization of M0 macrophages to M2-type by inhibiting notch1 signaling pathway and induce the secretion of anti-inflammatory cytokines; thus, it significantly ameliorates bone metabolism, which contributes to improving the osseointegration between the PT and osteoporotic bone. Conclusion The therapeutic potential of hierarchical PT implants containing controlled release system are effective in geriatric orthopaedic osseointegration. Graphical Abstract ![]()
Supplementary Information The online version contains supplementary material available at 10.1186/s12951-022-01277-0.
Collapse
|
16
|
Katakam A, Hosseinzadeh S, Humphrey TJ, Collins A, Shin D, Melnic CM, Bragdon C, Bedair HS. Different Designs of Proximal Femoral Stems for Total Hip Arthroplasty: Mid-Term Clinical and Patient-Reported Functional Outcomes. Cureus 2021; 13:e19745. [PMID: 34938623 PMCID: PMC8684824 DOI: 10.7759/cureus.19745] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/19/2021] [Indexed: 11/25/2022] Open
Abstract
INTRODUCTION A comprehensive comparison of the performance of different femoral stem geometries in total hip arthroplasty (THA) is yet to be described. The primary aim of this study was to evaluate objective and subjective outcome measures in primary THA with different femoral implant styles. METHODS Stems were classified into the following five classes: cemented, conical, fit and fill, modular, and wedge. The objective outcomes of interest were the length of inpatient hospital stay (LOS), 90-day readmission rate, one-year revision rate, and two-year mortality rate. Preoperative and postoperative patient-reported outcome measures (PROMs), including hip disability and osteoarthritis outcome score (HOOS) - physical function shortform (HOOS-PS), patient-reported outcomes measurement information system physical function short form 10a (PROMIS PF-10a), and patient-reported outcomes measurement information system - short form - mental 10a (PROMIS M-10a) were recorded and compared between different classes. RESULTS Patients with a wedge stem had a significantly lower LOS versus every other stem group, while patients with a cemented stem had the highest LOS, approximately twofold that of the wedge stem group. Accounting for potential confounders, the conical and fit and fill groups had a significantly higher two-year mortality rate than the wedge stem group. Fit and fill stems conferred a slight risk of revision THA at one-year compared to wedge stems. There was no significant difference in the rates of failure to achieve the minimal clinically important difference (MCID) for the PROMs. CONCLUSION Placement of wedge stems resulted in a significantly lower LOS compared to every other stem class and a lower mortality rate than the conical, fit and fill, and modular stems. As for the 90-day readmission, one-year revision, and the rates of failure to achieve the MCID for general or hip-specific PROMs, stem design had no meaningful effect.
Collapse
Affiliation(s)
- Akhil Katakam
- Orthopaedics, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| | - Shayan Hosseinzadeh
- Orthopaedics, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| | - Tyler J Humphrey
- Orthopaedics, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| | - Austin Collins
- Orthopaedics, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| | - David Shin
- Orthopaedics, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| | - Christopher M Melnic
- Orthopaedics, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| | - Charles Bragdon
- Orthopaedics, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| | - Hany S Bedair
- Orthopaedics, Massachusetts General Hospital, Harvard Medical School, Boston, USA
| |
Collapse
|
17
|
Kooner S, Kayum S, Pinsker EB, Al Khalifa A, Khan RM, Halai M, Daniels TR. Two-Year Outcomes After Total Ankle Replacement With a Novel Fixed-Bearing Implant. Foot Ankle Int 2021; 42:1002-1010. [PMID: 34024139 DOI: 10.1177/10711007211005781] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The Integra Cadence total ankle replacement (TAR) is a fourth-generation anatomic, fixed-bearing implant requiring minimal tibial and talar resection, which has been in clinical use since June 2016. The primary purpose of this study is to assess its short-term clinical and radiographic outcomes after TAR using this prosthesis. METHODS This is a prospective case series of consecutive patients that underwent TAR using this novel fourth-generation prosthesis between June 2016 and November 2017. The primary outcome of interest was the Ankle Osteoarthritis Scale (AOS). Secondary outcomes included Short Form Health Survey-36 (SF-36) scores, radiographic alignment, complications, reoperations, and revisions. RESULTS In total, 69 patients were included in our study. Fifty-one patients (73.9%) required a total of 91 ancillary procedures. Postoperatively, AOS pain scores decreased significantly by an average of 17.8±30.1 points from 45.9±18.2 to 28.4±27.3 (P < .001). AOS disability scores also decreased significantly following surgery by an average of 22.0±30.5 points from 53.9±18.5 to 32.5±27.9 (P < .001). The SF-36 physical component summary score improved 10.4±9.8 points from 33.1±9.1 to 42.6±9.1 (P < .001). Radiographic analysis demonstrated significant improvement to neutral coronal plane alignment, which was achieved in 97% of patients (P < .01) with no cyst formation at 2 years. There was 1 reported complication, 9 reoperations, and no metal or polyethylene component revisions. Overall, the 2-year implant survivorship was 100% in our cohort. Eighteen patients (26.1%) demonstrated fibrous ingrowth of the tibial component. However, outcome scores for these patients did not demonstrate any negative effects. CONCLUSION In our hands, this TAR system demonstrated excellent early clinical and radiographic outcomes. Patients reported improved physical health status, pain, and disability in the postoperative period. Total ankle instrumentation allowed for accurate and reproducible implantation with correction of coronal and sagittal plane deformities. Early results for the clinical use of this TAR system are promising, but further long-term prospective outcome studies are necessary. LEVEL OF EVIDENCE Level IV, case series.
Collapse
Affiliation(s)
| | - Shahin Kayum
- Unity Health Toronto-St Michael's Hospital, Toronto, Ontario, Canada
| | - Ellie B Pinsker
- Unity Health Toronto-St Michael's Hospital, Toronto, Ontario, Canada
| | | | - Ryan M Khan
- Unity Health Toronto-St Michael's Hospital, Toronto, Ontario, Canada
| | - Mansur Halai
- Unity Health Toronto-St Michael's Hospital, Toronto, Ontario, Canada
- University of Toronto, Toronto, Ontario, Canada
| | - Timothy R Daniels
- Unity Health Toronto-St Michael's Hospital, Toronto, Ontario, Canada
- University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
18
|
Ferreño Márquez DM, Dauder Gallego C, Bebea Zamorano FNG, Sebastián Pérez V, Montejo Sancho J, Martínez Martín J. Long-Term Outcomes of 496 Anatomical Cementless Modular Femoral Stems: Eleven to Twenty Years of Follow-Up. J Arthroplasty 2021; 36:2087-2099. [PMID: 33610406 DOI: 10.1016/j.arth.2021.01.057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Revised: 01/16/2021] [Accepted: 01/19/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND The aim of the study is to assess the long-term outcomes of this specific stem (anatomical cementless modular stem ESOP), to review the survivorship, complication rate, and radiographic and clinical outcomes. METHODS Descriptive and analytical retrospective longitudinal observational study of patients was operated on total hip arthroplasty between 1998 and 2007. Four hundred ninety-six prostheses corresponding to 447 patients were reviewed, mean age was 65.8 years (standard deviation [SD] ±11.6 years), and median follow-up time was 13.4 years (range 1-20). The most used cups were cementless (75.8%). The most frequent friction pairs were metal-polyethylene (53.1%) and ceramic-polyethylene (24.2%). Main variables analyzed were stem survival, subsidence, coronal orientation, osteolysis, reintervention, and Oxford Hip Score. RESULTS From 496 implants, there were 22 lost to follow-up (4.4%). Stem revision was performed in 51 patients: 26 periprosthetic joint infections (2-stage revision), 16 periprosthetic fractures, and 8 one-stage revisions (6 real aseptic loosening with negative culture after revision). The stem survivorship at more than 15 years for any reason was 89.2% and for aseptic loosening 97.97%. No specific complications were found due to modularity. The mean subsidence and orientation was 2.06 mm (SD ±5.11 mm) and 0.41° varus (SD ±2.20°) respectively. Subsidence >5 mm or varus >5° was associated with a higher revision rate. Osteolysis was found in 110 patients (zone I = 79, VII = 57), associated with zirconium-polyethylene, without relationship to the stem revision rate or Oxford Hip Score. CONCLUSION To our knowledge, this study represents the largest series of this stem, revealing an excellent survival rate and long-term clinical outcomes similar to the best results of classical cementless stems published in the literature.
Collapse
Affiliation(s)
| | | | | | | | - Jorge Montejo Sancho
- Department of Orthopaedic Surgery, Hospital Universitario Fundación Alcorcón, Madrid, Spain
| | - Javier Martínez Martín
- Department of Orthopaedic Surgery, Hospital Universitario Fundación Alcorcón, Madrid, Spain
| |
Collapse
|
19
|
Kostretzis L, Lavigne M, Kiss MO, Shahin M, Barry J, Vendittoli PA. Despite higher revision rate, MoM large-head THA offers better clinical scores than HR: 14-year results from a randomized controlled trial involving 48 patients. BMC Musculoskelet Disord 2021; 22:400. [PMID: 33941155 PMCID: PMC8091753 DOI: 10.1186/s12891-021-04286-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Accepted: 04/22/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The high failure rates of metal on metal (MoM) large diameter head total hip arthroplasty (LDH THA) and hip resurfacing (HR) prevented their long-term comparisons with regards to clinical outcome. Such knowledge would be important as ceramic LDH bearing is now available. With long-term follow-up, we investigated the difference in 1) patient-reported outcome measures (PROMs); 2) revision and adverse events rates, and 3) metal ion levels between MoM LDH THA and HR. METHODS Forty-eight patients were randomized for LDH THA (24) or HR (24) with the same MoM articulation. At a mean follow-up of 14 years, we compared between groups different PROMs, the number of revisions and adverse events, whole blood Cobalt (Co) and Chromium (Cr) ion levels, and radiographic signs of implant dysfunction. RESULTS LDH THA (all cases: revised and well-functioning) had significantly better WOMAC (94 versus 85, p = 0.04), and more frequently reported having no limitation (p = 0.04). LDH THA revision rate was 20.8% (5/24) versus 8.3% (2/24) for HR (p = 0.4). Mean Co and Cr ion levels were higher in LDH THA compared to the HR (Co: 3.8 μg/L vs 1.7 μg/L; p = 0.04 and Cr: 1.9 μg/L vs 1.4 μg/L, p = 0.1). On radiographic analyses, 2 LDH THAs showed signs of adverse reaction to metal debris, whereas 1 loose femoral HR component was documented. CONCLUSION In the long-term, MoM LDH THA had a high trunnion related revision rate but nonetheless showed better PROMs compared to HR. Provided with a well-functioning modular junction, non-MoM LDH THA would offer an appealing option. TRIAL REGISTRATION ClinicalTrials.gov ( NCT04516239 ), August 18, 2020. Retrospectively registered.
Collapse
Affiliation(s)
- Lazaros Kostretzis
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, 5415 Boulevard de l'Assomption, Montréal, Québec, H1T 2M4, Canada
| | - Martin Lavigne
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, 5415 Boulevard de l'Assomption, Montréal, Québec, H1T 2M4, Canada
| | - Marc-Olivier Kiss
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, 5415 Boulevard de l'Assomption, Montréal, Québec, H1T 2M4, Canada
| | - Maged Shahin
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, 5415 Boulevard de l'Assomption, Montréal, Québec, H1T 2M4, Canada
| | - Janie Barry
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, 5415 Boulevard de l'Assomption, Montréal, Québec, H1T 2M4, Canada
| | - Pascal-André Vendittoli
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, 5415 Boulevard de l'Assomption, Montréal, Québec, H1T 2M4, Canada.
| |
Collapse
|
20
|
Munakata Y, Kuramitsu Y, Usui Y, Okazaki K. Comparison of radiographic changes in rectangular curved short stem with thin versus thick porous coating for cementless total hip arthroplasty: a retrospective study with a propensity score matching. J Orthop Surg Res 2021; 16:247. [PMID: 33849591 PMCID: PMC8042942 DOI: 10.1186/s13018-021-02397-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Accepted: 04/05/2021] [Indexed: 11/12/2022] Open
Abstract
Background Radiographic changes that appear relatively quickly after fixation of cementless stem in total hip arthroplasty (THA) vary depending on the stem design and fixation style. The present study compared radiographic changes between two types of rectangular curved short stems of similar shape. Methods This retrospective study included 118 hips that underwent primary cementless THA with an anterolateral supine approach using a rectangular, curved, short stem performed by the same surgeon between June 2015 and June 2019. Among the examined hips, 39 had a thicker porous coating stem (thicker group) and 66 had a thinner porous coating and reduced tip stem (thinner group) and at least 12-month follow-up. Radiographs taken during the final course observation were assessed. Propensity score matching was performed based on demographic data and comparisons were made using pairs of 25 hips each. Statistical analysis was performed using chi-square test and p values ≤ 0.05 indicated statistical significance. Results The pattern of the radiolucent lines showed a significant difference after matching (p = 0.0044). A “proximal and distal” pattern was most common in the thicker group and a “distal only” pattern was most common in the thinner group. There was notable and significant difference in cortical hypertrophy in the thicker group after matching (p = 0.024). Conclusions Although the two short stems were similar shapes, the short-term radiographic changes were different. The thinner group showed fewer radiographic changes than the thicker group, making it a more “silent” stem.
Collapse
Affiliation(s)
- Yutaro Munakata
- Department of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1, Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan
| | - Yujiro Kuramitsu
- Department of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1, Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan
| | - Yutaka Usui
- Department of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1, Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan
| | - Ken Okazaki
- Department of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1, Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan.
| |
Collapse
|
21
|
Won SH, Park JW, Lee YK, Ha YC, Koo KH. No Clinically Important Differences in Thigh Pain or Bone Loss Between Short Stems and Conventional-length Stems in THA: A Randomized Clinical Trial. Clin Orthop Relat Res 2021; 479:767-777. [PMID: 33009239 PMCID: PMC8083837 DOI: 10.1097/corr.0000000000001505] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Accepted: 08/26/2020] [Indexed: 01/31/2023]
Abstract
BACKGROUND Short-length stems were developed to reduce bone loss of the proximal femur and potentially decrease the incidence of thigh pain after cementless THA. However, it remains unknown whether short stems indeed reduce bone loss or the frequency of thigh pain. QUESTIONS/PURPOSES Is there a difference between short- and standard-length stems in terms of: (1) the frequency or severity of thigh pain, (2) modified Harris hip scores, (3) implant loosening, or (4) bone mineral density as measured by dual-energy x-ray absorptiometry? METHODS Between March 2013 and January 2014, three surgeons performed 205 primary THAs. To be eligible, patients needed to be at least 20 years of age, have not undergone previous history of hip surgery, and have no metabolic bone disease. A total of 100 patients were randomized to receive THA either with a short stem (n = 56) or with a standard-length stem (n = 44). Both stems were proximally coated, tapered, cementless stems. Compared with standard stems, short stems typically were 30- to 35-mm shorter. A total of 73% (41 of 56) and 77% (34 of 44) of those groups, respectively, were accounted for at a minimum of 5 years and were analyzed. The presence of thigh pain during activity was evaluated using a 10-point VAS, and the modified Harris hip score was calculated by research assistants who were blinded to the treatment groups. Plain radiographs were taken at 6 weeks, 6 months, and 12 months postoperatively, and every 1 year thereafter; loosening was defined as subsidence > 3 mm or a position change > 3° on serial radiographs. Radiological assessment was performed by two researchers who did not participate in the surgery and follow-up evaluations. Bone mineral density of the proximal femur was measured using dual-energy x-ray absorptiometry at 4 days, 1 year, 2 years, and 5 years postoperatively. The primary endpoint of our study was the incidence of thigh pain during 5-year follow-up. Our study was powered at 80% to detect a 10% difference in the proportion of patients reporting thigh pain at the level of 0.05. RESULTS With the numbers available, we found no difference between the groups in the proportion of patients with thigh pain; 16% (9 of 56) of patients in the short-stem group and 14% (6 of 44) of patients in the standard-stem group experienced thigh pain during the follow-up period (p = 0.79). In all patients, the pain was mild or moderate (VAS score of 4 or 6 points). Among the 15 available patients who reported thigh pain, there was no difference between the implant groups in mean severity of thigh pain (4.3 ± 0.8 versus 4.2 ± 0.7; p = 0.78). There were no between-group differences in the short versus standard-length stem groups in terms of mean modified Harris hip score by 5 years after surgery (89 ± 13 versus 95 ± 7 points; p = 0.06). No implant was loose and no hip underwent revision in either group. Patients in the short-stem group showed a slightly smaller decrease in bone mineral density in Gruen Zones 2, 3, and 5 than those in the standard-stem group did; the magnitude of the difference seems unlikely to be clinically important. CONCLUSION We found no clinically important differences (and few differences overall) between short and standard-length THA stems 5 years after surgery in a randomized trial. Consequently, we recommend that clinicians use standard-length stems in general practice because standard-length stems have a much longer published track record in other studies, and short stems can expose patients to the uncertainty associated with novelty, without any apparent offsetting benefit. LEVEL OF EVIDENCE Level I, therapeutic study.
Collapse
MESH Headings
- Absorptiometry, Photon
- Adult
- Arthralgia/diagnosis
- Arthralgia/etiology
- Arthralgia/physiopathology
- Arthralgia/prevention & control
- Arthroplasty, Replacement, Hip/adverse effects
- Arthroplasty, Replacement, Hip/instrumentation
- Biomechanical Phenomena
- Bone Density
- Female
- Hip Joint/diagnostic imaging
- Hip Joint/physiopathology
- Hip Joint/surgery
- Hip Prosthesis
- Humans
- Male
- Middle Aged
- Osteoporosis/diagnostic imaging
- Osteoporosis/etiology
- Osteoporosis/physiopathology
- Osteoporosis/prevention & control
- Pain Measurement
- Pain Threshold
- Pain, Postoperative/diagnosis
- Pain, Postoperative/etiology
- Pain, Postoperative/physiopathology
- Pain, Postoperative/prevention & control
- Prosthesis Design
- Range of Motion, Articular
- Recovery of Function
- Republic of Korea
- Time Factors
- Treatment Outcome
Collapse
Affiliation(s)
- Seok-Hyung Won
- S.-H. Won, Y.-K. Lee, K.-H. Koo, Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
- J.-W. Park, Y.-C. Ha, Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Seoul, South Korea
- K.-H. Koo, Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, South Korea
| | - Jung-Wee Park
- S.-H. Won, Y.-K. Lee, K.-H. Koo, Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
- J.-W. Park, Y.-C. Ha, Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Seoul, South Korea
- K.-H. Koo, Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, South Korea
| | - Young-Kyun Lee
- S.-H. Won, Y.-K. Lee, K.-H. Koo, Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
- J.-W. Park, Y.-C. Ha, Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Seoul, South Korea
- K.-H. Koo, Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, South Korea
| | - Yong-Chan Ha
- S.-H. Won, Y.-K. Lee, K.-H. Koo, Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
- J.-W. Park, Y.-C. Ha, Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Seoul, South Korea
- K.-H. Koo, Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, South Korea
| | - Kyung-Hoi Koo
- S.-H. Won, Y.-K. Lee, K.-H. Koo, Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
- J.-W. Park, Y.-C. Ha, Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Seoul, South Korea
- K.-H. Koo, Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, South Korea
| |
Collapse
|
22
|
"Off-label" Usage of an Oxidized Zirconium Femoral Head in Revision of a Total Hip Arthroplasty with Mechanically Assisted Crevice Corrosion and a Legacy Taper. Arthroplast Today 2021; 8:69-73. [PMID: 33681438 PMCID: PMC7930501 DOI: 10.1016/j.artd.2021.01.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Revised: 01/20/2021] [Accepted: 01/23/2021] [Indexed: 11/22/2022] Open
Abstract
We present a case of a 72-year-old male with a history of a late 1980s metal-on-polyethylene total hip arthroplasty who presented with unilateral leg vascular compromise, joint pain, and stiffness and subsequently underwent revision for adverse local tissue reaction secondary to mechanically assisted crevice corrosion. His stable and extensively porous coated femoral implant had a legacy taper with no currently manufactured option for a non–Co-alloy femoral head. After shared decision-making with the patient, we opted to use an oxidized zirconium femoral head from another manufacturer with a similar taper during his revision surgery and documented that his vascular compromise resolved and his serum Co was undetectable 3 years after the revision.
Collapse
|
23
|
Gómez-Vallejo J, Roces-García J, Moreta J, Donaire-Hoyas D, Gayoso Ó, Marqués-López F, Albareda J. Biomechanical Behavior of an Hydroxyapatite-Coated Traditional Hip Stem and a Short One of Similar Design: Comparative Study Using Finite Element Analysis. Arthroplast Today 2021; 7:167-176. [PMID: 33553545 PMCID: PMC7856394 DOI: 10.1016/j.artd.2020.11.022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Revised: 11/24/2020] [Accepted: 11/25/2020] [Indexed: 11/23/2022] Open
Abstract
Background The objective is to compare, by the means of finite elements analysis, the biomechanical behavior of a conventional stem of proven performance with a short stem based on the same fixation principles. Methods A 3D femur was modeled from CT scan data, and real bone density measures were incorporated into it. Load stresses were applied to that bone in 3 different scenarios: without prosthesis, with the conventional stem, and with the short stem. Different bone loading patterns were compared by Gruen’s zones both visually and statistically using Welch’s test. Results The implantation of a stem generates a certain degree of stress shielding in the surrounding bone, but the pattern of the change is very similar in the compared stem models. Although there is statistical significance (P < 0.01) in the mean stress variation in most of the Gruen’s zones, the magnitude of the difference is always under 2 MPa (range: 0.01 – 1.74 MPa). Conclusions The bone loading patterns of the traditional stem and the short stem are very similar. Although there is no evidence of a link between biomechanics and clinical outcomes, our results may suggest that theoretical advantages of short stems can be exploited without the fear of altering bone loading patterns.
Collapse
Affiliation(s)
- Jesús Gómez-Vallejo
- Department of Orthopaedic Surgery, Hospital Clínico Universitario Lozano Blesa, Zaragoza, Spain
| | - Jorge Roces-García
- Department of Construction and Manufacturing Engineering, University of Oviedo, Oviedo, Spain
| | - Jesús Moreta
- Group of Lower Limb Reconstructive Surgery, Biocruces Bizkaia Health Research Institute, Osakidetza. Department of Orthopaedic Surgery and Traumatology, Hospital Galdakao-Usansolo, Bizkaia, Spain
| | | | - Óscar Gayoso
- Department of Orthopaedic Surgery, Hospital San Rafael, La Coruña, Spain
| | | | - Jorge Albareda
- Department of Orthopaedic Surgery, Hospital Clínico Universitario Lozano Blesa, Zaragoza, Spain
| |
Collapse
|
24
|
Bone remodelling, around an anatomical hip stem: A one year prospective study using DEXA. Rev Esp Cir Ortop Traumatol (Engl Ed) 2021. [DOI: 10.1016/j.recote.2020.09.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
25
|
Long-Term Survival and Results at a Mean Follow-Up Period of 24 Years of a Tapered Straight, Collarless, Grit-Blasted, Titanium Alloy Stem. J Arthroplasty 2020; 35:3644-3649. [PMID: 32660799 DOI: 10.1016/j.arth.2020.06.044] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 06/12/2020] [Accepted: 06/16/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND There is limited evidence on the survivorship of patients who undergo cementless stem implantation, beyond 20 years of the hip arthroplasty. We report implant survival and results of the CLS Spotorno femoral stem until 30 years from implantation. METHODS Survival analysis of 147 CLS Spotorno stems in 119 patients for an average period of 24 years (20-30) from the date of implantation was performed. During the course of the follow-up period, 33 patients (39 hips) died. The information on the survival of their hip implant at the time of death was gathered from their relatives and general practitioners. Sixty-six patients (86 hips) undertook the complete survey along with radiographic examination, while 18 subjects (20 hips) were interviewed over the telephone. The factors influencing survival, functional outcomes, and level of satisfaction with surgery were evaluated. RESULTS The overall estimated survival of the stems was 89.9% after 30 years (95% confidence interval [CI] 83.5-93.9). Survival with femoral revision for aseptic loosening as an end point was 93.1% (95% CI 87.1-96.4). In the worst-case scenario, an overall implant survival of 77.2% (95 CI% 80.3-82.7) was observed after 24 years. Patients who were older than 50 in age at the time of surgery had better survival rates (P = .026). The mean Harris Hip Score at follow-up was 83.1 (range 43-100) and the level of satisfaction was 9/10. The main determinant of postsurgical satisfaction was Harris Hip Score, whereas radiographic alterations explained little with respect to the variation in the outcomes. CONCLUSION The cementless CLS Spotorno stem displayed satisfactory results 24 years after implantation and high estimated survival until 30 years from surgery. However, patients below the age of 50 at the time of surgery have an increased risk of undergoing revision of their femoral stem.
Collapse
|
26
|
Kaszuba SV, Cipparrone N, Gordon AC. The Actis and Corail Femoral Stems Provide for Similar Clinical and Radiographic Outcomes in Total Hip Arthroplasty. HSS J 2020; 16:412-419. [PMID: 33380975 PMCID: PMC7749906 DOI: 10.1007/s11420-020-09792-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Accepted: 08/16/2020] [Indexed: 02/07/2023]
Abstract
BACKGROUND The introduction of new devices for total hip arthroplasty (THA) offers surgeons the ability to address deficits in the portfolio. However, once introduced, data regarding the performance of devices is not publicly available until their use is widespread. PURPOSE/QUESTIONS The objective of this study was to compare the clinical and radiographic performance, including patient reported outcomes and radiographic evidence of osseointegration, subsidence, and stress shielding, of the newer Actis femoral component to the Corail stem (DePuy Synthes, Warsaw, IN, USA), which has an extensive clinical history. METHODS This short-term, retrospective cohort study was a single surgeon series of 330 anterior approach THAs, consisting of 165 cases using the Actis stem and 165 cases using the Corail stem. Both devices were cementless, titanium, tapered, hydroxyapatite-coated stems. They differed in geometry, neck choices, broach philosophy, and collar availability. Data was obtained for 1 year following THA. Functional outcomes were measured with the Hip Dysfunction and Osteoarthritis Outcome Score for Joint Replacement (HOOS, JR.) survey. Complications were recorded from patient charts, and radiographic analysis was performed for signs of osseointegration, subsidence, and stress shielding. RESULTS The groups shared similar demographic characteristics except the Actis population was younger with fewer women. The complication rate did not significantly vary, and no patient required revision within the first year. Radiographically, one patient in each group demonstrated subsidence. No cases exhibited radiolucent lines, and the prevalence of stress shielding at 1 year was comparable. HOOS, JR. scores did not significantly vary at 8 weeks or 1 year. CONCLUSION The Actis stem does not carry an increased risk of device-related complications compared with the Corail implant. Although aspects of bone remodeling differed between groups, Actis achieved radiographic signs of bone ingrowth at the 1-year mark and performed well clinically, with equivalent patient reported outcome scores to the Corail stem.
Collapse
Affiliation(s)
- Stephanie V. Kaszuba
- grid.477350.20000 0004 1794 7030Department of Orthopedic Surgery, Illinois Bone & Joint Institute, 9000 Waukegan Road, Suite 200, Morton Grove, IL 60053 USA ,grid.262641.50000 0004 0388 7807Chicago Medical School, Rosalind Franklin University of Medicine and Science, North Chicago, IL USA
| | - Nancy Cipparrone
- grid.477350.20000 0004 1794 7030Department of Orthopedic Surgery, Illinois Bone & Joint Institute, 9000 Waukegan Road, Suite 200, Morton Grove, IL 60053 USA
| | - Alexander C. Gordon
- grid.477350.20000 0004 1794 7030Department of Orthopedic Surgery, Illinois Bone & Joint Institute, 9000 Waukegan Road, Suite 200, Morton Grove, IL 60053 USA ,grid.413334.20000 0004 0435 6004Department of Orthopedic Surgery, Advocate Lutheran General Hospital, Park Ridge, IL USA ,grid.416274.20000 0004 0457 7309Department of Orthopedic Surgery, NorthShore Skokie Hospital, Skokie, IL USA
| |
Collapse
|
27
|
Suh D, Jo WL, Kim SC, Kim YS, Kwon SY, Lim YW. Comparative analysis of titanium coating on cobalt-chrome alloy in vitro and in vivo direct metal fabrication vs. plasma spraying. J Orthop Surg Res 2020; 15:564. [PMID: 33243258 PMCID: PMC7690187 DOI: 10.1186/s13018-020-02108-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2020] [Accepted: 11/19/2020] [Indexed: 11/25/2022] Open
Abstract
Background Titanium surface coating on cobalt-chromium (CoCr) alloy has characteristics desirable for an orthopedic implant as follows: strength, osteointegrative capability, and biocompatibility. Creating such a coated surface takes a challenging process and two dissimilar metals are not easily welded. In our study, we utilized additive manufacturing with a 3D printing called direct metal fabrication (DMF) and compared it to the plasma spraying method (TPS), to coat titanium onto CoCr alloy. We hypothesized that this would yield a coated surface quality as acceptable or better than the already established method of plasma spraying. For this, we compared characteristics of titanium-coated surfaces created by direct metal fabrication method (DMF) and titanium plasma spraying (TPS), both in vitro and in vivo, for (1) cell morphology, (2) confocal microscopy images of immunofluorescent assay of RUNX2 and fibronectin, (3) quantification of cell proliferation rate, (4) push-out biomechanical test, and (5) bone histomorphometry. Method For in vitro study, human osteoblast cells were seeded onto the coated surfaces. Cellular morphology was observed with a scanning electron microscope. Cellular proliferation was validated with ELISA, immunofluorescent assay. For in vivo study, coated rods were inserted into the distal femur of the rabbit and then harvested. The rods were biomechanically tested with a push-out test and observed for histomorphometry to evaluate the microscopic bone to implant ratio. Result For cell morphology observation, lamellipodia and filopodia, a cytoplasmic projection extending into porous structure, formed on both surfaces created by DMF and TPS. The proliferation of the osteoblasts, the DMF group showed a better result at different optic density levels (p = 0.035, 0.005, 0.001). Expression and distribution of fibronectin and Runx-2 genes showed similar degrees of expressions. The biomechanical push-out test yielded a similar result (p = 0.714). Histomorphometry analysis also showed a similar result (p = 0.657). Conclusion In conclusion, DMF is a method which can reliably create a proper titanium surface on CoCr alloy. The resulting product of the surface shows a similar quality to that of the plasma spraying method, both in vivo and in vitro, in terms of biological and mechanical property.
Collapse
Affiliation(s)
- Dongwhan Suh
- Department of Orthopaedic Surgery, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.,Department of Orthopaedic Surgery, Daejeon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Woo Lam Jo
- Department of Orthopaedic Surgery, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.,Department of Orthopaedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Seung Chan Kim
- Department of Orthopaedic Surgery, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.,Department of Orthopaedic Surgery, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Yong Sik Kim
- Department of Orthopaedic Surgery, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.,Department of Orthopaedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Soon Yong Kwon
- Department of Orthopaedic Surgery, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.,Department of Orthopaedic Surgery, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Young Wook Lim
- Department of Orthopaedic Surgery, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea. .,Department of Orthopaedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
| |
Collapse
|
28
|
Bone remodeling, around an anatomical hip stem: a one year prospective study using DEXA. Rev Esp Cir Ortop Traumatol (Engl Ed) 2020; 65:31-40. [PMID: 33177012 DOI: 10.1016/j.recot.2020.09.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2019] [Revised: 07/24/2020] [Accepted: 09/28/2020] [Indexed: 11/23/2022] Open
Abstract
INTRODUCTION The loss of bone mass, as a consequence of bone remodelling, in the proximal third of the femur, is a factor that contributes to the failure of hip prostheses in the medium to long term. This periprosthetic remodelling occurs mainly during the first 12 months after the operation. The aim is to evaluate the behaviour at one year of a new anatomical stem, the ANATO® stem (2015-Stryker®), which is a redesign of its predecessor (ABG-ii®-Stryker stem) by means of bone densitometry. METHOD Prospective, controlled study in which the changes in bone mineral density (BMD) observed around the seven areas of Gruen in a group of 61 patients affected by primary coxarthrosis, in whom an ANATO® stem was implanted, are analysed densitometrically. The healthy hip was taken as the control group. The existence of differences in the remodelling pattern according to sex, age and body mass index (BMI) was compared. The follow-up was during the first year after the intervention. RESULTS After one year of follow-up, decreases of bone mineral density in zone seven of -5.9% were observed, being this decrease statistically significant. No differences were found in the remodelling pattern according to age, sex and body mass index. CONCLUSION The ANATO® stem allows an efficient transmission of loads from the stem to the proximal femur. Only in zone seven significant bone atrophy is observed. Differences in age, BMI and sex do not seem to influence the bone remodelling around this new stem.
Collapse
|
29
|
Vendittoli PA, Shahin M, Rivière C, Roy AG, Barry J, Lavigne M. Hip Resurfacing Compared with 28-mm Metal-on-Metal Total Hip Replacement: A Randomized Study with 15 Years of Follow-up. J Bone Joint Surg Am 2020; 102:80-90. [PMID: 32554999 DOI: 10.2106/jbjs.20.00030] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Bone stock conservation, hip anatomy preservation, and greater stability are among the promoted advantages of hip resurfacing (HR). However, the disappointing failure of some implants nearly led to its abandonment. The aim of this study was to compare clinical scores and revision and complication rates after HR with those after total hip arthroplasty (THA). METHODS Two hundred and three hips were randomized to 28-mm metal-on-metal (MoM) THA (99 hips) or to HR (104 hips). Main outcome measures compared between groups were the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, the revision rate, and the complication rates. The radiographic findings were also assessed. RESULTS After a mean follow-up of 15 years (range, 14 to 16 years), 9 (4.4%) of the 203 patients were lost to follow-up and 15 (7.4%) had died. The Kaplan-Meier survivorship, with revision for any reason as the end point, was 89.2% (95% confidence interval [CI], 82.3% to 96.1%) for HR and 94.2% (95% CI, 89.3% to 99.1%) for THA (p = 0.292). The reasons for revision included infection (3 patients), recurrent dislocation (1 patient), and adverse reaction to metal debris (ARMD) (1 patient) in the THA group and ARMD (2 patients) and femoral head loosening (7 patients) in the HR group. With aseptic revision as the end point, the Kaplan-Meier survivorship was significantly higher in the THA group (97.4% versus 89.2%; p = 0.033). No dislocation occurred in the HR group compared with 4 in the THA group (p = 0.058). Both groups achieved a similar mean WOMAC score (10.7 in the HR group and 8.8 in the THA group; p = 0.749), Forgotten Joint Score (87.1 and 85.3, respectively; p = 0.410), University of California Los Angeles (UCLA) activity score (6.3 and 6.4, respectively; p = 0.189), and overall joint perception (p = 0.251). CONCLUSIONS The specific HR and MoM 28-mm THA implants used in this study showed good long-term survival and function. The overall rates of complications and revisions were similar in both groups but were of different types. As it provides better femoral bone preservation and biomechanical reconstruction, HR may continue to have a role in selected patients when performed by experienced surgeons and using validated implants. LEVEL OF EVIDENCE Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Pascal-André Vendittoli
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montréal, Québec, Canada
| | - Maged Shahin
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montréal, Québec, Canada
| | | | - Alain Guy Roy
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montréal, Québec, Canada
| | - Janie Barry
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montréal, Québec, Canada
| | - Martin Lavigne
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montréal, Québec, Canada
| |
Collapse
|
30
|
Kayaalp ME, Can A, Erdogan F, Ozsahin MK, Aydingoz O, Kaynak G. Clinical and Radiological Results of Crowe Type 3 or 4 Dysplasia Patients Operated on With Total Hip Arthroplasty Using a Cementless Rectangular Femoral Component Without Fixating or Grafting the Transverse Osteotomy Site. J Arthroplasty 2020; 35:2537-2542. [PMID: 32418747 DOI: 10.1016/j.arth.2020.04.045] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2020] [Revised: 04/06/2020] [Accepted: 04/16/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Total hip arthroplasty (THA) involving shortening osteotomy for patients with Crowe type 3 or 4 dysplasia is a challenging surgical procedure. This study aims to demonstrate that rectangular femoral component use in anatomical reconstructions with THA and transverse shortening osteotomy yields successful results without the use of bone graft or any fixation material at the osteotomy site. METHODS Fifty hips from 41 patients were identified retrospectively as per study objectives. All patients were evaluated using the Harris Hip Score and Visual Analog Scale for pain. Complications were reported. Radiological evaluation criteria were then evaluated, including leg length discrepancy, degree of trochanter caudalization and stem subsidence, radiolucent and radiodense lines for both components and bone atrophy or hypertrophy around the stem according to Gruen zones, and the canal fill ratio of the stem. RESULTS Postoperative Harris Hip Score was excellent for 68% of patients. No patient had poor results. Complication rate was 32%. One patient had nonunion (2%). The mean postoperative leg length discrepancy was 0.8(±0.6) cm. No patient had a subsidence of more than 5 mm. Radiolucent and radiodense lines were present in up to 34% of patients, and bone atrophy was present in the proximal femur in up to 96% of patients. No patient had osteolysis or loosening in neither component. CONCLUSION Successful clinical and radiological results can be obtained from Crowe type 3 and 4 dysplastic hips operated on with THA using a rectangular femoral component and transverse shortening osteotomy technique. The use of graft or any fixation material at the osteotomy site is not mandatory.
Collapse
Affiliation(s)
- Mahmut Enes Kayaalp
- Department of Orthopedics and Traumatology, Istanbul Taksim Training and Research Hospital, Istanbul, Turkey
| | - Ata Can
- Nisantasi Orthopaedics Center, Istanbul, Turkey
| | | | - Mahmut Kursat Ozsahin
- Department of Orthopaedics and Traumatology, Cerrahpasa Faculty of Medicine, Istanbul University-Cerrahpasa, Istanbul, Turkey
| | - Onder Aydingoz
- Department of Orthopaedics and Traumatology, Cerrahpasa Faculty of Medicine, Istanbul University-Cerrahpasa, Istanbul, Turkey
| | - Gokhan Kaynak
- Department of Orthopaedics and Traumatology, Cerrahpasa Faculty of Medicine, Istanbul University-Cerrahpasa, Istanbul, Turkey
| |
Collapse
|
31
|
Gong L, Zhang YY, Yang N, Qian HJ, Zhang LK, Tan MS. Raloxifene Prevents Early Periprosthetic Bone Loss for Postmenopausal Women after Uncemented Total Hip Arthroplasty: A Randomized Placebo-Controlled Clinical Trial. Orthop Surg 2020; 12:1074-1083. [PMID: 32686337 PMCID: PMC7454213 DOI: 10.1111/os.12696] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Revised: 04/15/2020] [Accepted: 04/16/2020] [Indexed: 01/06/2023] Open
Abstract
OBJECTIVE To examine the results of raloxifene for prevention of periprosthetic bone loss around the femoral stem in patients undergoing total hip arthroplasty (THA). METHODS Between January 2015 and May 2017, 240 female patients between 55 and 80 years underwent primary THA and were randomly allocated to receive 60 mg raloxifene hydrochloride per day (treatment group, TG, n = 120) or placebo (control group, CG, n = 120) orally at bedtime using computer-generated randomization sequence generation. Baseline data, the Western Ontario McMaster Universities Osteoarthritis Index (WOMAC), women's quality of life (QoL) score, bone mineral density (BMD) around the prosthesis, and adverse events were compared between the two groups. The measuring range of BMD around the prosthesis was divided into seven regions of interest (ROI). The sample size was calculated to detect a mean difference in BMD of 0.15 g/cm2 with a standard deviation (SD) of 0.3. The error was set at 0.05 and the power level at 90% with additional compensation for a possible dropout rate of 20%. RESULTS A total of 240 participants in the study up to 24 months after THA. There were no significant differences in the mean BMD of all the zones between groups before surgery (all P > 0.05). However, there were significant differences in the BMD of Gruen zones 4 and 7 between groups at 6 months postoperatively (both P < 0.05); there were significant differences in Gruen zones 1, 4, 6, and 7 at 12 months postoperatively (all P < 0.01); there were significant differences in Gruen zones 1, 2, 4, 6, and 7 at 24 months postoperatively (all P < 0.001). Patients taking raloxifene reported higher QoL scores, with better improvement in BMD in all areas except in zones 3 and 5 compared with the control group. There were no significant differences in WOMAC pain (P = 0.4045), WOMAC function (P = 0.4456) and women's QoL scores (P = 0.5983) between groups before surgery. However, WOMAC pain, WOMAC function and women's QoL score in the treatment group were significantly better at all time points (all P < 0.05). Patients in the treatment group showed no increased adverse events, including cardiac events, stroke, venous thromboembolism, and gynecological cancer (all P > 0.05), but did show decreased odds of breast cancer in comparison with those using a placebo (P = 0.0437). CONCLUSION Raloxifene can help inhibit bone loss around the prosthesis and improve the QoL of postmenopausal women after THA with no increased adverse events, and can even decrease the odds of breast cancer.
Collapse
Affiliation(s)
- Long Gong
- Department of Orthopaedic Surgery, China-Japan Friendship Hospital, Peking Union Medical College, Chinese Academy of Medical College, Beijing, China
| | - Yao-Yao Zhang
- Department of Obstetrics and Gynecology, West China Second University Hospital of Sichuan University, Chengdu, China.,Key Laboratory of Birth Defects and Related Diseases of Women and Children of the Ministry of Education, Chengdu, China
| | - Na Yang
- Bao Ding Maternal and Children Hospital, Baoding, China
| | - Huan-Juan Qian
- Department of Orthopedics Surgery, 81 Group Military Hospital of Chinese PLA, Baoding, China
| | - Ling-Kun Zhang
- Department of Orthopedics Surgery, 81 Group Military Hospital of Chinese PLA, Baoding, China
| | - Ming-Sheng Tan
- Department of Orthopaedic Surgery, China-Japan Friendship Hospital, Peking Union Medical College, Chinese Academy of Medical College, Beijing, China
| |
Collapse
|
32
|
Panisello JJ, Lopez J, Lillo M, Mateo J, Martin C, Herrera A. Bone Remodeling of Two Anatomic Stems: Densitometric Study of the Redesign of the ABG-II Stem. Arthroplast Today 2020; 6:480-486. [PMID: 32671168 PMCID: PMC7338879 DOI: 10.1016/j.artd.2020.05.020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Revised: 04/10/2020] [Accepted: 05/27/2020] [Indexed: 12/01/2022] Open
Abstract
Background Periprosthetic bone remodeling, which is a phenomenon observed in all femoral stems, has a multifactorial origin as it depends on factors related to the patient, the surgical technique, and the design of the implant. To determine the pattern of remodeling produced by 2 models of anatomic cementless implants, we quantified the changes in bone mineral density (BMD) in the 7 areas of Gruen observed at different moments after surgery during the first postoperative year. Methods A prospective, comparative, controlled, 1-year follow-up densitometric study was carried out in 2 groups of patients suffering from primary unilateral hip osteoarthritis. In the first group, with 68 patients, an ABG-II stem was implanted. In the second, with 66 patients, the ANATO stem was used. The contralateral, healthy hip was taken as a control. Results Both groups showed a decrease in BMD at 3 months in all the areas, which recovered at the end of the study, except in zone 7: there was a 17.7% decrease in the ABG-II group and a 5.9% decrease in the ANATO group. In zones 2 and 6, where more loads are transmitted, conservation of BMD is observed in response to Wolff's law. The differences in the pattern of remodeling between groups were maintained despite the age, gender, and BMI of the patients or the size of the implants. Conclusion The ANATO stem achieved a more efficient transmission of loads at the metaphyseal level, which promotes bone preservation at the proximal femur, than the ABG-II stem.
Collapse
Affiliation(s)
- Juan J Panisello
- Adult Hip Unit, Department of Orthopaedic Surgery, Miguel Servet University Hospital, Zaragoza, Spain
| | - Jorge Lopez
- Adult Hip Unit, Department of Orthopaedic Surgery, Miguel Servet University Hospital, Zaragoza, Spain
| | - Marina Lillo
- Adult Hip Unit, Department of Orthopaedic Surgery, Miguel Servet University Hospital, Zaragoza, Spain
| | - Jesus Mateo
- Adult Hip Unit, Department of Orthopaedic Surgery, Miguel Servet University Hospital, Zaragoza, Spain
| | - Carlos Martin
- Adult Hip Unit, Department of Orthopaedic Surgery, Miguel Servet University Hospital, Zaragoza, Spain
| | - Antonio Herrera
- Adult Hip Unit, Department of Orthopaedic Surgery, Miguel Servet University Hospital, Zaragoza, Spain
| |
Collapse
|
33
|
Ding Z, Ling T, Mou P, Wang D, Zhou K, Zhou Z. Bone restoration after revision hip arthroplasty with femoral bone defects using extensively porous-coated stems with cortical strut allografts. J Orthop Surg Res 2020; 15:194. [PMID: 32460781 PMCID: PMC7254662 DOI: 10.1186/s13018-020-01720-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Accepted: 05/20/2020] [Indexed: 02/08/2023] Open
Abstract
Background Stress shielding and bone loss of the femur are of great concern after revision total hip arthroplasty (THA) with extensively porous-coated stems, especially in a femur with already bone loss. The femoral bone remodeling patterns after revision THA with femoral bone defects using extensively porous-coated stems with cortical strut allografts remain unclear. Methods We retrospectively reviewed 47 patients who underwent revision THA using extensively porous-coated stems combined with cortical strut allografts and 75 patients without allografts. The minimum follow-up was 2 years. Femoral bone remodeling signs, including stress shielding, bone restoration in bone defect area, distal cortical hypertrophy, and femoral width, were compared between patients with and without cortical strut allografts. Clinical outcomes were also compared between two groups. Results Patients with cortical strut allografts showed less severe stress shielding (P = 0.01) than patients without allografts. Patients with allografts had more osseous restoration in bone defect area than patients without allografts (63.8% vs 30.7%, P < 0.001). Femoral width was significantly higher in femur with allografts than in femur without allografts at the immediate postoperative stage and latest follow-up (both P < 0.001). The hip function score, re-revision rate, and complications were comparable between two groups. Conclusion The application of cortical strut allografts can decrease the severity of stress shielding, augment osseous restoration in bone defect area and improve femoral bone stock after revision THA using extensively porous-coated stems.
Collapse
Affiliation(s)
- Zichuan Ding
- Department of Orthopedics, West China Hospital/West China School of Medicine, Sichuan University, 37# Wuhou Guoxue Road, Chengdu, People's Republic of China
| | - Tingxian Ling
- Department of Orthopedics, West China Hospital/West China School of Medicine, Sichuan University, 37# Wuhou Guoxue Road, Chengdu, People's Republic of China
| | - Ping Mou
- Department of Orthopedics, West China Hospital/West China School of Medicine, Sichuan University, 37# Wuhou Guoxue Road, Chengdu, People's Republic of China
| | - Duan Wang
- Department of Orthopedics, West China Hospital/West China School of Medicine, Sichuan University, 37# Wuhou Guoxue Road, Chengdu, People's Republic of China
| | - Kai Zhou
- Department of Orthopedics, West China Hospital/West China School of Medicine, Sichuan University, 37# Wuhou Guoxue Road, Chengdu, People's Republic of China
| | - Zongke Zhou
- Department of Orthopedics, West China Hospital/West China School of Medicine, Sichuan University, 37# Wuhou Guoxue Road, Chengdu, People's Republic of China.
| |
Collapse
|
34
|
Influence of Hydroxyapatite Coating for the Prevention of Bone Mineral Density Loss and Bone Metabolism after Total Hip Arthroplasty: Assessment Using 18F-Fluoride Positron Emission Tomography and Dual-Energy X-Ray Absorptiometry by Randomized Controlled Trial. BIOMED RESEARCH INTERNATIONAL 2020; 2020:4154290. [PMID: 32185203 PMCID: PMC7060431 DOI: 10.1155/2020/4154290] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/06/2019] [Revised: 01/22/2020] [Accepted: 01/31/2020] [Indexed: 11/17/2022]
Abstract
Background Hydroxyapatite- (HA-) coated implants tend to achieve good osteoinductivity and stable clinical results; however, the influence of the coating on the prevention of bone mineral density (BMD) loss around the implant is unclear. The purpose of this randomized controlled trial was to evaluate the effectiveness of HA-coated implants for preventing BMD loss and to determine the status of bone remodeling after total hip arthroplasty (THA), making comparisons with non-HA-coated implants. Methods A total of 52 patients who underwent primary THA were randomly allocated to HA and non-HA groups. BMD was measured by dual-energy X-ray absorptiometry (DEXA) at 1 week postoperation to form a baseline measurement, and then 24 weeks and 48 weeks after surgery. The relative change in BMD was evaluated for regions of interest (ROIs) based on the Gruen zone classifications. 18F-fluoride positron emission tomography (PET) was performed at 24 weeks postsurgery, and the maximum standardized uptake values (SUVmax) were evaluated in the proximal (HA-coated) and distal (non-HA-coated) areas in both groups. Results There were significant differences in BMD loss in ROIs 3 and 6 (p = 0.03), while no significant difference was observed in ROI 7 at either 24 or 48 weeks postsurgery. There was no significant correlation between PET uptake and BMD (24 or 48 weeks) in either group. Conclusion The influence of a HA coating in terms of BMD preservation is limited. No significant correlation was found between BMD and SUVmax measured by PET, either with or without the use of a HA coating.
Collapse
|
35
|
Iwase T, Morita D, Takemoto G. The effects of patient characteristics and stem alignment on distal femoral cortical hypertrophy after cemented polished tapered stem implantation. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2019; 30:559-567. [PMID: 31853636 DOI: 10.1007/s00590-019-02605-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2019] [Accepted: 12/13/2019] [Indexed: 12/27/2022]
Abstract
BACKGROUND The objective of this study was to evaluate the results of over 10 years of total hip arthroplasty (THA) practice with ExeterTM stems and the clinical relevance of distal femoral cortical hypertrophy (DFCH). METHODS We retrospectively reviewed 127 hips (120 patients) that had undergone THA with ExeterTM stems between 2004 and 2007. Kaplan-Meier survival analyses for the stem of all 127 hips were performed using different endpoints. Of 127 hips, 100 (94 patients) had complete 10-year follow-up data, including the Japanese Orthopaedic Association Hip Disease Evaluation Questionnaire (JHEQ) as the patient-reported outcomes, and the clinical relevance of DFCH was analyzed using multivariable logistic regression analysis. RESULTS The survival of the stem with the endpoint of re-operation for loosening, > 5-mm subsidence, and re-operation for any reason were 100%, 99.1% (95% CI 97.5-100%), and 98.3% (95% CI 96.0-100%), respectively. Of 100 hips followed completely for 10 years, DFCH occurred in 20 hips (20%). The satisfaction and pain visual analog scale of JHEQ revealed high satisfaction and less pain in patients with DFCH. By multivariate logistic regression analysis, body weight > 55 kg (odds ratio: 2.88, p = 0.035) and varus stem alignment (odds ratio: 6.56, p = 0.003) were found to be predictors for DFCH. CONCLUSIONS The incidence of DFCH with the ExeterTM stem was 20%. A body weight > 55 kg and varus stem alignment are predictors for future DFCH. DFCH with the ExeterTM stem indicates a good outcome with less hip pain.
Collapse
Affiliation(s)
- Toshiki Iwase
- Department of Orthopedic Surgery, Hamamatsu Medical Center, 328 Tomitsuka-cho, Naka-ku, Hamamatsu, Shizuoka, 432-8580, Japan.
| | - Daigo Morita
- Department of Orthopedic Surgery, Hamamatsu Medical Center, 328 Tomitsuka-cho, Naka-ku, Hamamatsu, Shizuoka, 432-8580, Japan
| | - Genta Takemoto
- Department of Orthopedic Surgery, Hamamatsu Medical Center, 328 Tomitsuka-cho, Naka-ku, Hamamatsu, Shizuoka, 432-8580, Japan
| |
Collapse
|
36
|
Karachalios T, Palaiochorlidis E, Komnos G. Clinical relevance of bone remodelling around conventional and conservative (short-stem) total hip arthroplasty implants. Hip Int 2019; 29:4-6. [PMID: 30421637 DOI: 10.1177/1120700018810846] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Based on data from the existing literature, we can safely suggest that bone mineral changes around cementless and cemented conventional femoral stems, and conservative femoral stems, are not predictive of either satisfactory or unsatisfactory total hip arthroplasty long term clinical outcomes. Additionally, studies with a follow up shorter than 5-10 years are perhaps clinically irrelevant. These observations may be helpful in interpreting the existing literature.
Collapse
|
37
|
Roessler PP, Jacobs C, Krause AC, Wimmer MD, Wagenhäuser PJ, Jaenisch M, Schildberg FA, Wirtz DC. Relative radiographic bone density measurement in revision hip arthroplasty and its correlation with qualitative subjective assessment by experienced surgeons. Technol Health Care 2018; 27:79-88. [PMID: 30452431 DOI: 10.3233/thc-181490] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Conventional radiography (CR) is the imaging method of choice in monitoring bone remodelling and other stability parameters after total hip arthroplasty (THA). Quantitative roentgen- or computed-tomography-based methods to determine bone density are prone to metal artifacts and often very costly, which is why they are not used as standard in a clinical setting. Since subjective assessment of bone remodelling in CR also has a certain susceptibility to errors, semi-quantitative methods have been developed to help approximate periprosthetic bone density development via CR to open up an additional tool for documentation of radiographic THA follow-up. OBJECTIVE Proof-of-principle of a newly designed imaging-software-aided method to measure relative bone density around the femoral stem in a series of conventional radiographs following THA. METHODS Eighty-six patients with hip modular tapered, fluted titanium stems were selected from the clinical database and series of baseline and postoperative follow-up radiographs were obtained after 24 and 48 weeks. Relative bone densities were measured per Gruen zones G1-7 with the use of an open-source image analysis package (ImageJ) by means of greyscale histograms. In addition, subjective evaluation of selected cases was performed by three independent, blinded orthopedic surgeons. Besides descriptive and nonparametric analyses, intra-class correlation (ICC) was performed and objective and subjective results were compared by linear regression analysis. RESULTS Two individual cases are presented as a proof-of-principle. Increase or decrease of bone density could be measured correctly over time in each case. In a collective analysis there were no significant differences in mean relative bone densities between groups after 24 and 48 weeks, although a positive tendency was visible towards increased bone formation over time. Individual analyses by Gruen zones revealed that some zones, namely the proximal ones (e.g. G6), exhibit a broader scattering than others over time. This could be explained by the design of the evaluated tapered revision stem that achieves distal fixation and allows for proximal micromotion. Correlation analysis with subjective ratings (inter-rater reliability ICC = 0.71) showed a positive correlation with objective results, suggesting a feasibility of the method for clinical use. CONCLUSIONS In conclusion the presented method is an easy and accessible tool to quantify relative bone density changes during THA follow-up. It shows a positive correlation to established subjective assessment of bone remodelling and may therefore serve as a quantitative supplement in clinical documentation.
Collapse
Affiliation(s)
- Philip P Roessler
- Department of Orthopedics and Traumatology, University Hospital Bonn, Bonn, Germany.,Department of Orthopedics and Traumatology, University Hospital Bonn, Bonn, Germany
| | - Cornelius Jacobs
- Department of Orthopedics and Traumatology, University Hospital Bonn, Bonn, Germany.,Department of Orthopedics and Traumatology, University Hospital Bonn, Bonn, Germany
| | - Amelie C Krause
- Department of Orthopedics and Traumatology, University Hospital Bonn, Bonn, Germany
| | - Matthias D Wimmer
- Department of Orthopedics and Traumatology, University Hospital Bonn, Bonn, Germany
| | | | - Max Jaenisch
- Department of Orthopedics and Traumatology, University Hospital Bonn, Bonn, Germany
| | - Frank A Schildberg
- Department of Orthopedics and Traumatology, University Hospital Bonn, Bonn, Germany.,Department of Orthopedics and Traumatology, University Hospital Bonn, Bonn, Germany
| | - Dieter C Wirtz
- Department of Orthopedics and Traumatology, University Hospital Bonn, Bonn, Germany.,Department of Orthopedics and Traumatology, University Hospital Bonn, Bonn, Germany
| |
Collapse
|
38
|
Wu XD, Chen Y, Wang ZY, Li YJ, Zhu ZL, Tao YZ, Chen H, Cheng Q, Huang W. Comparison of periprosthetic bone remodeling after implantation of anatomic and tapered cementless femoral stems in total hip arthroplasty: A prospective cohort study protocol. Medicine (Baltimore) 2018; 97:e12560. [PMID: 30278556 PMCID: PMC6181628 DOI: 10.1097/md.0000000000012560] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
INTRODUCTION Current total hip arthroplasty (THA) implant usage trends favor cementless fixation, and plenty studies have demonstrated that numbers of cementless femoral stems are associated with excellent long-term survivorship and functional outcomes. Various types of cementless femoral stems have been developed and utilized in multiple applications, including straight, tapered, anatomic, customized, short, and even neck stems. All of these designs aimed to achieve maximal primary stability and promote osseointegration. Nevertheless, stress-shielding and periprosthetic bone loss continue to occur and remain critical issues in promoting long-term survivorship of THA. Considering anatomic and tapered stems are the most popular cementless designs today, this prospective cohort study aimed to investigate the effect of stem design on stress-shielding and periprosthetic bone remodeling after implantation of an anatomic stem with proximal fixation (Ribbed Hip system; Waldemar Link, Hamburg, Germany) and the direct comparison to a fully coated tapered stem (LCU Hip system; Waldemar Link). MATERIALS AND METHODS This prospective cohort study will comprise patients who receive primary unilateral THA with the Ribbed anatomic hydroxyapatite (HA)-coated stem or LCU tapered fully HA-coated stem. The changes in periprosthetic bone mineral density after insertion of Ribbed and LCU stem prostheses will be assessed by means of dual-energy X-ray absorptiometry in the periprosthetic region of interest according to Gruen and colleagues. Standard anteroposterior and lateral plain radiography will be performed for qualitative assessment of the periprosthetic bone remodeling. The following items will be analyzed or measured on follow-up radiographs to compare with the initial appearance on the radiographs taken immediately postoperatively: cortical thickness in each Gruen zone, fitness of the distal stem within the isthmus, femoral stem alignment, radiolucent line, reactive line, periosteal bone reactions, and subsidence. Biologic fixation and stability of the cementless implant will be evaluated using Engh grading scale, and heterotopic ossification will be graded according to Brooker classification. Furthermore, Harris hip score and Western Ontario and McMaster Universities Osteoarthritis Index Score will also be assessed for postoperative functional evaluation. These radiologic and clinical assessments will be taken postoperatively, at 6 months, 1, 2, 3, 4, and 5 years after surgery. ETHICS AND DISSEMINATION This study was approved by The First Affiliated Hospital of Chongqing Medical University Ethics Committee. The study results will be disseminated at national and international conferences and published in peer-reviewed journals. STUDY REGISTRATION Chinese Clinical Trial Registry (http://www.chictr.org.cn): ChiCTR1800017841.
Collapse
|