Konovalov AB, Vlasov VV, Samarin SI, Soloviev ID, Savitsky AP, Tuchin VV. Reconstruction of fluorophore absorption and fluorescence lifetime using early photon mesoscopic fluorescence molecular tomography: a phantom study. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:126001. [PMID: 36519075 PMCID: PMC9743783 DOI: 10.1117/1.jbo.27.12.126001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/27/2022] [Accepted: 11/18/2022] [Indexed: 06/17/2023]
Abstract
SIGNIFICANCE Fluorescence molecular lifetime tomography (FMLT) plays an increasingly important role in experimental oncology. The article presents and experimentally verifies an original method of mesoscopic time domain FMLT, based on an asymptotic approximation to the fluorescence source function, which is valid for early arriving photons. AIM The aim was to justify the efficiency of the method by experimental scanning and reconstruction of a phantom with a fluorophore. The experimental facility included the TCSPC system, the pulsed supercontinuum Fianium laser, and a three-channel fiber probe. Phantom scanning was done in mesoscopic regime for three-dimensional (3D) reflectance geometry. APPROACH The sensitivity functions were simulated with a Monte Carlo method. A compressed-sensing-like reconstruction algorithm was used to solve the inverse problem for the fluorescence parameter distribution function, which included the fluorophore absorption coefficient and fluorescence lifetime distributions. The distributions were separated directly in the time domain with the QR-factorization least square method. RESULTS 3D tomograms of fluorescence parameters were obtained and analyzed using two strategies for the formation of measurement data arrays and sensitivity matrices. An algorithm is developed for the flexible choice of optimal strategy in view of attaining better reconstruction quality. Variants on how to improve the method are proposed, specifically, through stepped extraction and further use of a posteriori information about the object. CONCLUSIONS Even if measurement data are limited, the proposed method is capable of giving adequate reconstructions but their quality depends on available a priori (or a posteriori) information. Further research aims to improve the method by implementing the variants proposed.
Collapse
Affiliation(s)
- Alexander B. Konovalov
- Federal State Unitary Enterprise “Russian Federal Nuclear Center – Zababakhin All-Russia Research Institute of Technical Physics,” Snezhinsk, Russia
- Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Moscow, Russia
| | - Vitaly V. Vlasov
- Federal State Unitary Enterprise “Russian Federal Nuclear Center – Zababakhin All-Russia Research Institute of Technical Physics,” Snezhinsk, Russia
- Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Moscow, Russia
| | - Sergei I. Samarin
- Federal State Unitary Enterprise “Russian Federal Nuclear Center – Zababakhin All-Russia Research Institute of Technical Physics,” Snezhinsk, Russia
| | - Ilya D. Soloviev
- Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Moscow, Russia
| | - Alexander P. Savitsky
- Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Moscow, Russia
| | - Valery V. Tuchin
- Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Moscow, Russia
- Saratov State University, Saratov, Russia
| |
Collapse
|
2
|
Wang Y, Li S, Wang Y, Yan Q, Wang X, Shen Y, Li Z, Kang F, Cao X, Zhu S. Compact fiber-free parallel-plane multi-wavelength diffuse optical tomography system for breast imaging. OPTICS EXPRESS 2022; 30:6469-6486. [PMID: 35299431 DOI: 10.1364/oe.448874] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Accepted: 02/05/2022] [Indexed: 06/14/2023]
Abstract
To facilitate the clinical applicability of the diffuse optical inspection device, a compact multi-wavelength diffuse optical tomography system for breast imaging (compact-DOTB) with a fiber-free parallel-plane structure was designed and fabricated for acquiring three-dimensional optical properties of the breast in continuous-wave mode. The source array consists of 56 surface-mounted micro light-emitting diodes (LEDs), each integrating three wavelengths (660, 750, and 840 nm). The detector array is arranged with 56 miniaturized surface-mounted optical sensors, each encapsulating a high-sensitivity photodiode (PD) and a low-noise current amplifier with a gain of 24×. The system provides 3,136 pairs of source-detector measurements at each wavelength, and the fiber-free design largely ensures consistency between source/detection channels while effectively reducing the complexity of system operation and maintenance. We have evaluated the compact-DOTB system's characteristics and demonstrated its performance in terms of reconstruction positioning accuracy and recovery contrast with breast-sized phantom experiments. Furthermore, the breast cancer patient studies have been carried out, and the quantitative results indicate that the compact-DOTB system is able to observe the changes in the functional tissue components of the breast after receiving the neoadjuvant chemotherapy (NAC), demonstrating the great potential of the proposed compact system for clinical applications, while its cost and ease of operation are competitive with the existing breast-DOT devices.
Collapse
|
3
|
Wang X, Hu R, Wang Y, Yan Q, Wang Y, Kang F, Zhu S. A Data Self-Calibration Method Based on High-Density Parallel Plate Diffuse Optical Tomography for Breast Cancer Imaging. Front Oncol 2021; 11:786289. [PMID: 34993144 PMCID: PMC8724432 DOI: 10.3389/fonc.2021.786289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Accepted: 12/03/2021] [Indexed: 11/13/2022] Open
Abstract
When performing the diffuse optical tomography (DOT) of the breast, the mismatch between the forward model and the experimental conditions will significantly hinder the reconstruction accuracy. Therefore, the reference measurement is commonly used to calibrate the measured data before the reconstruction. However, it is complicated to customize corresponding reference phantoms based on the breast shape and background optical parameters of different subjects in clinical trials. Furthermore, although high-density (HD) DOT configuration has been proven to improve imaging quality, a large number of source-detector (SD) pairs also increase the difficulty of multi-channel correction. To enhance the applicability of the breast DOT, a data self-calibration method based on an HD parallel-plate DOT system is proposed in this paper to replace the conventional relative measurement on a reference phantom. The reference predicted data can be constructed directly from the measurement data with the support of the HD-DOT system, which has nearly a hundred sets of measurements at each SD distance. The proposed scheme has been validated by Monte Carlo (MC) simulation, breast-size phantom experiments, and clinical trials, exhibiting the feasibility in ensuring the quality of the DOT reconstruction while effectively reducing the complexity associated with relative measurements on reference phantoms.
Collapse
Affiliation(s)
- Xin Wang
- School of Life Science and Technology, Xidian University, Xi’an, China
- Engineering Research Center of Molecular and Neuro Imaging of Ministry of Education, Xi’an, China
| | - Rui Hu
- School of Life Science and Technology, Xidian University, Xi’an, China
- Engineering Research Center of Molecular and Neuro Imaging of Ministry of Education, Xi’an, China
| | - Yirong Wang
- Department of Nuclear Medicine, Xijing Hospital, Fourth Military Medical University, Xi’an, China
| | - Qiang Yan
- School of Life Science and Technology, Xidian University, Xi’an, China
- Engineering Research Center of Molecular and Neuro Imaging of Ministry of Education, Xi’an, China
| | - Yihan Wang
- School of Life Science and Technology, Xidian University, Xi’an, China
- Engineering Research Center of Molecular and Neuro Imaging of Ministry of Education, Xi’an, China
- *Correspondence: Yihan Wang, ; Shouping Zhu,
| | - Fei Kang
- Department of Nuclear Medicine, Xijing Hospital, Fourth Military Medical University, Xi’an, China
| | - Shouping Zhu
- School of Life Science and Technology, Xidian University, Xi’an, China
- Engineering Research Center of Molecular and Neuro Imaging of Ministry of Education, Xi’an, China
- *Correspondence: Yihan Wang, ; Shouping Zhu,
| |
Collapse
|
4
|
Yang F, Gong X, Faulkner D, Gao S, Yao R, Zhang Y, Intes X. Accelerating vasculature imaging in tumor using mesoscopic fluorescence molecular tomography via a hybrid reconstruction strategy. Biochem Biophys Res Commun 2021; 562:29-35. [PMID: 34030042 DOI: 10.1016/j.bbrc.2021.05.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Accepted: 05/09/2021] [Indexed: 10/21/2022]
Abstract
Mesoscopic fluorescent molecular tomography (MFMT) enables to image fluorescent molecular probes beyond the typical depth limits of microscopic imaging and with enhanced resolution compared to macroscopic imaging. However, MFMT is a scattering-based inverse problem that is an ill-posed inverse problem and hence, requires relative complex iterative solvers coupled with regularization strategies. Inspired by the potential of deep learning in performing image formation tasks from raw measurements, this work proposes a hybrid approach to solve the MFMT inverse problem. This methodology combines a convolutional symmetric network and a conventional iterative algorithm to accelerate the reconstruction procedure. By the proposed deep neural network, the principal components of the sensitivity matrix are extracted and the accompanying noise in measurements is suppressed, which helps to accelerate the reconstruction and improve the accuracy of results. We apply the proposed method to reconstruct in silico and vascular tree models. The results demonstrate that reconstruction accuracy and speed are highly improved due to the reduction of redundant entries of the sensitivity matrix and noise suppression.
Collapse
Affiliation(s)
- Fugang Yang
- School of Information and Electronic Engineering, Shandong Technology and Business University, Yantai, 264005, China
| | - Xue Gong
- School of Information and Electronic Engineering, Shandong Technology and Business University, Yantai, 264005, China.
| | - Denzel Faulkner
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, 110 8th Street, Troy, NY, 12180, USA
| | - Shan Gao
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, 110 8th Street, Troy, NY, 12180, USA
| | - Ruoyang Yao
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, 110 8th Street, Troy, NY, 12180, USA
| | - Yanli Zhang
- School of Information and Electronic Engineering, Shandong Technology and Business University, Yantai, 264005, China
| | - Xavier Intes
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, 110 8th Street, Troy, NY, 12180, USA
| |
Collapse
|
5
|
Konovalov AB, Vlasov VV, Uglov AS. Early-photon reflectance fluorescence molecular tomography for small animal imaging: Mathematical model and numerical experiment. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2021; 37:e03408. [PMID: 33094558 DOI: 10.1002/cnm.3408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Revised: 10/04/2020] [Accepted: 10/17/2020] [Indexed: 06/11/2023]
Abstract
The paper presents an original approach to time-domain reflectance fluorescence molecular tomography (FMT) of small animals. It is based on the use of early arriving photons and state-of-the-art compressed-sensing-like reconstruction algorithms and aims to improve the spatial resolution of fluorescent images. We deduce the fundamental equation that models the imaging operator and derive analytical representations for the sensitivity functions which are responsible for the reconstruction of the fluorophore absorption coefficient. The idea of fluorescence lifetime tomography with our approach is also discussed. We conduct a numerical experiment on 3D reconstruction of box phantoms with spherical fluorescent inclusions of small diameters. For modeling measurement data and constructing the sensitivity matrix we assume a virtual fluorescence tomograph with a scanning fiber probe that illuminates and collects light in reflectance geometry. It provides for large source-receiver separations which correspond to the macroscopic regime. Two compressed-sensing-like reconstruction algorithms are used to solve the inverse problem. These are the algebraic reconstruction technique with total variation regularization and our modification of the fast iterative shrinkage-thresholding algorithm. Results of our numerical experiment show that our approach is capable of achieving as good spatial resolution as 0.2 mm and even better at depths to 9 mm inclusive.
Collapse
Affiliation(s)
- Alexander B Konovalov
- Computational Center, Federal State Unitary Enterprise "Russian Federal Nuclear Center - Zababakhin All-Russia Research Institute of Technical Physics,", Snezhinsk, Russia
- Laboratory of Molecular Imaging, Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Moscow, Russia
| | - Vitaly V Vlasov
- Computational Center, Federal State Unitary Enterprise "Russian Federal Nuclear Center - Zababakhin All-Russia Research Institute of Technical Physics,", Snezhinsk, Russia
- Laboratory of Molecular Imaging, Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Moscow, Russia
| | - Alexander S Uglov
- Computational Center, Federal State Unitary Enterprise "Russian Federal Nuclear Center - Zababakhin All-Russia Research Institute of Technical Physics,", Snezhinsk, Russia
| |
Collapse
|
6
|
Nouizi F, Kwong TC, Ruiz J, Cho J, Chan YW, Ikemura K, Erkol H, Sampathkumaran U, Gulsen G. A thermo-sensitive fluorescent agent based method for excitation light leakage rejection for fluorescence molecular tomography. Phys Med Biol 2019; 64:035007. [PMID: 30561380 DOI: 10.1088/1361-6560/aaf96d] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Fluorescence molecular tomography (FMT) is widely used in preclinical oncology research. FMT is the only imaging technique able to provide 3D distribution of fluorescent probes within thick highly scattering media. However, its integration into clinical medicine has been hampered by its low spatial resolution caused by the undetermined and ill-posed nature of its reconstruction algorithm. Another major factor degrading the quality of FMT images is the large backscattered excitation light component leaking through the rejection filters and coinciding with the weak fluorescent signal arising from a low tissue fluorescence concentration. In this paper, we present a new method based on the use of a novel thermo-sensitive fluorescence probe. In fact, the excitation light leakage is accurately estimated from a set of measurements performed at different temperatures and then is corrected for in the tomographic data. The obtained results show a considerable improvement in both spatial resolution and quantitative accuracy of FMT images due to the proper correction of fluorescent signals.
Collapse
Affiliation(s)
- Farouk Nouizi
- Department of Radiological Sciences, Tu and Yuen Center for Functional Onco-Imaging, University of California, Irvine, CA 92697, United States of America
| | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Hernandez-Quintanar L, Rodriguez-Salvador M. Discovering new 3D bioprinting applications: Analyzing the case of optical tissue phantoms. Int J Bioprint 2018; 5:178. [PMID: 32596533 PMCID: PMC7294689 DOI: 10.18063/ijb.v5i1.178] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2018] [Accepted: 12/18/2018] [Indexed: 11/25/2022] Open
Abstract
Optical tissue phantoms enable to mimic the optical properties of biological tissues for biomedical device calibration, new equipment validation, and clinical training for the detection, and treatment of diseases. Unfortunately, current methods for their development present some problems, such as a lack of repeatability in their optical properties. Where the use of three-dimensional (3D) printing or 3D bioprinting could address these issues. This paper aims to evaluate the use of this technology in the development of optical tissue phantoms. A competitive technology intelligence methodology was applied by analyzing Scopus, Web of Science, and patents from January 1, 2000, to July 31, 2018. The main trends regarding methods, materials, and uses, as well as predominant countries, institutions, and journals, were determined. The results revealed that, while 3D printing is already employed (in total, 108 scientific papers and 18 patent families were identified), 3D bioprinting is not yet applied for optical tissue phantoms. Nevertheless, it is expected to have significant growth. This research gives biomedical scientists a new window of opportunity for exploring the use of 3D bioprinting in a new area that may support testing of new equipment and development of techniques for the diagnosis and treatment of diseases.
Collapse
|
8
|
Towards in-vivo assessment of fluorescence lifetime: imaging using time-gated intensified CCD camera. Biocybern Biomed Eng 2018. [DOI: 10.1016/j.bbe.2018.08.006] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
9
|
Wan W, Wang Y, Qi J, Liu L, Ma W, Li J, Zhang L, Zhou Z, Zhao H, Gao F. Region-based diffuse optical tomography with registered atlas: in vivo acquisition of mouse optical properties. BIOMEDICAL OPTICS EXPRESS 2016; 7:5066-5080. [PMID: 28018725 PMCID: PMC5175552 DOI: 10.1364/boe.7.005066] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2016] [Revised: 10/20/2016] [Accepted: 11/09/2016] [Indexed: 05/14/2023]
Abstract
The reconstruction quality in the model-based optical tomography modalities can greatly benefit from a priori information of accurate tissue optical properties, which are difficult to be obtained in vivo with a conventional diffuse optical tomography (DOT) system alone. One of the solutions is to apply a priori anatomical structures obtained with anatomical imaging systems such as X-ray computed tomography (XCT) to constrain the reconstruction process of DOT. However, since X-ray offers low soft-tissue contrast, segmentation of abdominal organs from sole XCT images can be problematic. In order to overcome the challenges, the current study proposes a novel method of recovering a priori organ-oriented tissue optical properties, where anatomical structures of an in vivo mouse are approximately obtained by registering a standard anatomical atlas, i.e., the Digimouse, to the target XCT volume with the non-rigid image registration, and, in turn, employed to guide DOT for extracting the optical properties of inner organs. Simulative investigations have validated the methodological availability of such atlas-registration-based DOT strategy in revealing both a priori anatomical structures and optical properties. Further experiments have demonstrated the feasibility of the proposed method for acquiring the organ-oriented tissue optical properties of in vivo mice, making it as an efficient way of the reconstruction enhancement.
Collapse
Affiliation(s)
- Wenbo Wan
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
| | - Yihan Wang
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
| | - Jin Qi
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Cancer Institute and Hospital, Tianjin Medical University, Tianjin 300060, China
| | - Lingling Liu
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
| | - Wenjuan Ma
- Cancer Institute and Hospital, Tianjin Medical University, Tianjin 300060, China
| | - Jiao Li
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin 300072, China
| | - Limin Zhang
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin 300072, China
| | - Zhongxing Zhou
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin 300072, China
| | - Huijuan Zhao
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin 300072, China
| | - Feng Gao
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin 300072, China
| |
Collapse
|
10
|
Cai C, Cai W, Cheng J, Yang Y, Luo J. Self-guided reconstruction for time-domain fluorescence molecular lifetime tomography. JOURNAL OF BIOMEDICAL OPTICS 2016; 21:126012. [PMID: 27999862 DOI: 10.1117/1.jbo.21.12.126012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2016] [Accepted: 11/30/2016] [Indexed: 06/06/2023]
Abstract
Fluorescence probes have distinct yields and lifetimes when located in different environments, which makes the reconstruction of fluorescence molecular lifetime tomography (FMLT) challenging. To enhance the reconstruction performance of time-domain (TD) FMLT with heterogeneous targets, a self-guided L 1 regularization projected steepest descent (SGL1PSD) algorithm is proposed. Different from other algorithms performed in time domain, SGL1PSD introduces a time-resolved strategy into fluorescence yield reconstruction. The algorithm consists of four steps. Step 1 reconstructs the initial yield map with full time gate strategy; steps 2–4 reconstruct the inverse lifetime map, the yield map, and the inverse lifetime map again with time-resolved strategy, respectively. The reconstruction result of each step is used as a priori for the reconstruction of the next step. Projected iterated Tikhonov regularization algorithm is adopted for the yield map reconstructions in steps 1 and 3 to provide a solution with iterative refinement and nonnegative constraint. The inverse lifetime map reconstructions in steps 2 and 4 are based on L 1 regularization projected steepest descent algorithm, which employ the L 1 regularization to reduce the ill-posedness of the high-dimensional nonlinear problem. Phantom experiments with heterogeneous targets at different edge-to-edge distances demonstrate that SG
Collapse
Affiliation(s)
- Chuangjian Cai
- Tsinghua University, School of Medicine, Department of Biomedical Engineering, Beijing 100084, China
| | - Wenjuan Cai
- Tsinghua University, School of Medicine, Department of Biomedical Engineering, Beijing 100084, China
| | - Jiaju Cheng
- Tsinghua University, School of Medicine, Department of Biomedical Engineering, Beijing 100084, China
| | - Yuxuan Yang
- Tsinghua University, School of Medicine, Department of Biomedical Engineering, Beijing 100084, China
| | - Jianwen Luo
- Tsinghua University, School of Medicine, Department of Biomedical Engineering, Beijing 100084, ChinabTsinghua University, Center for Biomedical Imaging Research, Beijing 100084, China
| |
Collapse
|
11
|
Nishimura G, Awasthi K, Furukawa D. Fluorescence lifetime measurements in heterogeneous scattering medium. JOURNAL OF BIOMEDICAL OPTICS 2016; 21:75013. [PMID: 27457203 DOI: 10.1117/1.jbo.21.7.075013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2016] [Accepted: 07/01/2016] [Indexed: 05/11/2023]
Abstract
Fluorescence lifetime in heterogeneous multiple light scattering systems is analyzed by an algorithm without solving the diffusion or radiative transfer equations. The algorithm assumes that the optical properties of medium are constant in the excitation and emission wavelength regions. If the assumption is correct and the fluorophore is a single species, the fluorescence lifetime can be determined by a set of measurements of temporal point-spread function of the excitation light and fluorescence at two different concentrations of the fluorophore. This method is not dependent on the heterogeneity of the optical properties of the medium as well as the geometry of the excitation–detection on an arbitrary shape of the sample. The algorithm was validated by an indocyanine green fluorescence in phantom measurements and demonstrated by an in vivo measurement.
Collapse
|
12
|
Wang X, Zhang Y, Zhang L, Li J, Zhou Z, Zhao H, Gao F. Direct reconstruction in CT-analogous pharmacokinetic diffuse fluorescence tomography: two-dimensional simulative and experimental validations. JOURNAL OF BIOMEDICAL OPTICS 2016; 21:46007. [PMID: 27093958 DOI: 10.1117/1.jbo.21.4.046007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2016] [Accepted: 03/22/2016] [Indexed: 06/05/2023]
Abstract
We present a generalized strategy for direct reconstruction in pharmacokinetic diffuse fluorescence tomography (DFT) with CT-analogous scanning mode, which can accomplish one-step reconstruction of the indocyanine-green pharmacokinetic-rate images within in vivo small animals by incorporating the compartmental kinetic model into an adaptive extended Kalman filtering scheme and using an instantaneous sampling dataset. This scheme, compared with the established indirect and direct methods, eliminates the interim error of the DFT inversion and relaxes the expensive requirement of the instrument for obtaining highly time-resolved date-sets of complete 360 deg projections. The scheme is validated by two-dimensional simulations for the two-compartment model and pilot phantom experiments for the one-compartment model, suggesting that the proposed method can estimate the compartmental concentrations and the pharmacokinetic-rates simultaneously with a fair quantitative and localization accuracy, and is well suitable for cost-effective and dense-sampling instrumentation based on the highly-sensitive photon counting technique.
Collapse
Affiliation(s)
- Xin Wang
- Tianjin University, College of Precision Instrument and Optoelectronics Engineering, Tianjin 300072, China
| | - Yanqi Zhang
- Tianjin University, College of Precision Instrument and Optoelectronics Engineering, Tianjin 300072, China
| | - Limin Zhang
- Tianjin University, College of Precision Instrument and Optoelectronics Engineering, Tianjin 300072, ChinabTianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin 300072, China
| | - Jiao Li
- Tianjin University, College of Precision Instrument and Optoelectronics Engineering, Tianjin 300072, ChinabTianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin 300072, China
| | - Zhongxing Zhou
- Tianjin University, College of Precision Instrument and Optoelectronics Engineering, Tianjin 300072, ChinabTianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin 300072, China
| | - Huijuan Zhao
- Tianjin University, College of Precision Instrument and Optoelectronics Engineering, Tianjin 300072, ChinabTianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin 300072, China
| | - Feng Gao
- Tianjin University, College of Precision Instrument and Optoelectronics Engineering, Tianjin 300072, ChinabTianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin 300072, China
| |
Collapse
|
13
|
Lin Y, Nouizi F, Kwong TC, Gulsen G. Simulation-based evaluation of the resolution and quantitative accuracy of temperature-modulated fluorescence tomography. APPLIED OPTICS 2015; 54:7612-21. [PMID: 26368884 PMCID: PMC4896397 DOI: 10.1364/ao.54.007612] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Conventional fluorescence tomography (FT) can recover the distribution of fluorescent agents within a highly scattering medium. However, poor spatial resolution remains its foremost limitation. Previously, we introduced a new fluorescence imaging technique termed "temperature-modulated fluorescence tomography" (TM-FT), which provides high-resolution images of fluorophore distribution. TM-FT is a multimodality technique that combines fluorescence imaging with focused ultrasound to locate thermo-sensitive fluorescence probes using a priori spatial information to drastically improve the resolution of conventional FT. In this paper, we present an extensive simulation study to evaluate the performance of the TM-FT technique on complex phantoms with multiple fluorescent targets of various sizes located at different depths. In addition, the performance of the TM-FT is tested in the presence of background fluorescence. The results obtained using our new method are systematically compared with those obtained with the conventional FT. Overall, TM-FT provides higher resolution and superior quantitative accuracy, making it an ideal candidate for in vivo preclinical and clinical imaging. For example, a 4 mm diameter inclusion positioned in the middle of a synthetic slab geometry phantom (D:40 mm×W:100 mm) is recovered as an elongated object in the conventional FT (x=4.5 mm; y=10.4 mm), while TM-FT recovers it successfully in both directions (x=3.8 mm; y=4.6 mm). As a result, the quantitative accuracy of the TM-FT is superior because it recovers the concentration of the agent with a 22% error, which is in contrast with the 83% error of the conventional FT.
Collapse
Affiliation(s)
- Yuting Lin
- Tu and Yuen Center for Functional Onco Imaging, Department of Radiological Sciences, University of California, Irvine, California 92697, USA
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114, USA
| | - Farouk Nouizi
- Tu and Yuen Center for Functional Onco Imaging, Department of Radiological Sciences, University of California, Irvine, California 92697, USA
| | - Tiffany C. Kwong
- Tu and Yuen Center for Functional Onco Imaging, Department of Radiological Sciences, University of California, Irvine, California 92697, USA
| | - Gultekin Gulsen
- Tu and Yuen Center for Functional Onco Imaging, Department of Radiological Sciences, University of California, Irvine, California 92697, USA
- Department of Biomedical Engineering, University of California, Irvine, California 92697, USA
| |
Collapse
|
14
|
Performance Enhancement of Pharmacokinetic Diffuse Fluorescence Tomography by Use of Adaptive Extended Kalman Filtering. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2015; 2015:739459. [PMID: 26089975 PMCID: PMC4452308 DOI: 10.1155/2015/739459] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/09/2014] [Revised: 01/20/2015] [Accepted: 01/20/2015] [Indexed: 11/30/2022]
Abstract
Due to both the physiological and morphological differences in the vascularization between healthy and diseased tissues, pharmacokinetic diffuse fluorescence tomography (DFT) can provide contrast-enhanced and comprehensive information for tumor diagnosis and staging. In this regime, the extended Kalman filtering (EKF) based method shows numerous advantages including accurate modeling, online estimation of multiparameters, and universal applicability to any optical fluorophore. Nevertheless the performance of the conventional EKF highly hinges on the exact and inaccessible prior knowledge about the initial values. To address the above issues, an adaptive-EKF scheme is proposed based on a two-compartmental model for the enhancement, which utilizes a variable forgetting-factor to compensate the inaccuracy of the initial states and emphasize the effect of the current data. It is demonstrated using two-dimensional simulative investigations on a circular domain that the proposed adaptive-EKF can obtain preferable estimation of the pharmacokinetic-rates to the conventional-EKF and the enhanced-EKF in terms of quantitativeness, noise robustness, and initialization independence. Further three-dimensional numerical experiments on a digital mouse model validate the efficacy of the method as applied in realistic biological systems.
Collapse
|
15
|
Wu L, Wan W, Wang X, Zhou Z, Li J, Zhang L, Zhao H, Gao F. Shape-parameterized diffuse optical tomography holds promise for sensitivity enhancement of fluorescence molecular tomography. BIOMEDICAL OPTICS EXPRESS 2014; 5:3640-59. [PMID: 25360379 PMCID: PMC4206331 DOI: 10.1364/boe.5.003640] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2014] [Revised: 08/31/2014] [Accepted: 09/12/2014] [Indexed: 05/03/2023]
Abstract
A fundamental approach to enhancing the sensitivity of the fluorescence molecular tomography (FMT) is to incorporate diffuse optical tomography (DOT) to modify the light propagation modeling. However, the traditional voxel-based DOT has been involving a severely ill-posed inverse problem and cannot retrieve the optical property distributions with the acceptable quantitative accuracy and spatial resolution. Although, with the aid of an anatomical imaging modality, the structural-prior-based DOT method with either the hard- or soft-prior scheme holds promise for in vivo acquiring the optical background of tissues, the low robustness of the hard-prior scheme to the segmentation error and inferior performance of the soft-prior one in the quantitative accuracy limit its further application. We propose in this paper a shape-parameterized DOT method for not only effectively determining the regional optical properties but potentially achieving reasonable structural amelioration, lending itself to FMT for comparably improved recovery of fluorescence distribution.
Collapse
Affiliation(s)
- Linhui Wu
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
| | - Wenbo Wan
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
| | - Xin Wang
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
| | - Zhongxing Zhou
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin 300072, China
| | - Jiao Li
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin 300072, China
| | - Limin Zhang
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin 300072, China
| | - Huijuan Zhao
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin 300072, China
| | - Feng Gao
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin 300072, China
| |
Collapse
|
16
|
Darne C, Lu Y, Sevick-Muraca EM. Small animal fluorescence and bioluminescence tomography: a review of approaches, algorithms and technology update. Phys Med Biol 2013; 59:R1-64. [PMID: 24334634 DOI: 10.1088/0031-9155/59/1/r1] [Citation(s) in RCA: 108] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Emerging fluorescence and bioluminescence tomography approaches have several common, yet several distinct features from established emission tomographies of PET and SPECT. Although both nuclear and optical imaging modalities involve counting of photons, nuclear imaging techniques collect the emitted high energy (100-511 keV) photons after radioactive decay of radionuclides while optical techniques count low-energy (1.5-4.1 eV) photons that are scattered and absorbed by tissues requiring models of light transport for quantitative image reconstruction. Fluorescence imaging has been recently translated into clinic demonstrating high sensitivity, modest tissue penetration depth, and fast, millisecond image acquisition times. As a consequence, the promise of quantitative optical tomography as a complement of small animal PET and SPECT remains high. In this review, we summarize the different instrumentation, methodological approaches and schema for inverse image reconstructions for optical tomography, including luminescence and fluorescence modalities, and comment on limitations and key technological advances needed for further discovery research and translation.
Collapse
|
17
|
Roman M, Gonzalez J, Carrasquilla J, Erickson SJ, Akhter R, Godavarty A. Resolution of a Gen-2 handheld optical imager: diffuse and fluorescence imaging studies. APPLIED OPTICS 2013; 52:8060-8066. [PMID: 24513758 DOI: 10.1364/ao.52.008060] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2013] [Accepted: 10/22/2013] [Indexed: 06/03/2023]
Abstract
A generation-2 (Gen-2) handheld optical imager capable of two-dimensional surface and three-dimensional tomographic imaging has recently been developed. Herein, the ability of the handheld imager to detect and resolve two targets under diffuse and fluorescence imaging conditions has been demonstrated via tissue phantom studies. Two-dimensional surface imaging studies demonstrated that two 0.96 cm diameter Indocyannine Green targets were detected and resolved ~0.5 cm apart (between edges) at a target depth of 1 cm during diffuse imaging and up to 2 cm depth during fluorescence imaging. Preliminary 3D tomographic imaging capability to resolve the two targets was also demonstrated, but requires extensive future studies.
Collapse
|
18
|
Li J, Yi X, Wang X, Lu Y, Zhang L, Zhao H, Gao F. Overlap time-gating approach for improving time-domain diffuse fluorescence tomography based on the IRF-calibrated Born normalization. OPTICS LETTERS 2013; 38:1841-1843. [PMID: 23722762 DOI: 10.1364/ol.38.001841] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Diffuse fluorescence tomography (DFT) methods using the full time-resolved (TR) data have been demonstrated to substantially improve the spatial resolution and quantitative accuracy of reconstructed images. However, these methods usually suffer from low practical feasibility because of the influence of the system impulse response function (IRF) and the trade-off between the used data time-resolution and the required signal-to-noise ratio (SNR). We present a full TR approach that combines an IRF-calibrated full TR Born normalization and an overlap-delaying time-gate scheme for attaining high SNR without sacrificing the TR information content. The approach is validated with full TR data from phantom experiments for its better performances in the spatial resolution and reconstruction fidelity compared to the traditional DFT methods.
Collapse
Affiliation(s)
- Jiao Li
- College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
| | | | | | | | | | | | | |
Collapse
|
19
|
Okawa S, Yano A, Uchida K, Mitsui Y, Yoshida M, Takekoshi M, Marjono A, Gao F, Hoshi Y, Kida I, Masamoto K, Yamada Y. Phantom and mouse experiments of time-domain fluorescence tomography using total light approach. BIOMEDICAL OPTICS EXPRESS 2013; 4:635-651. [PMID: 23577297 PMCID: PMC3617724 DOI: 10.1364/boe.4.000635] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/31/2012] [Revised: 01/12/2013] [Accepted: 02/14/2013] [Indexed: 06/02/2023]
Abstract
Phantom and mouse experiments of time-domain fluorescence tomography were conducted to demonstrate the total light approach which was previously proposed by authors. The total light approach reduces the computation time to solve the forward model for light propagation. Time-resolved temporal profiles were acquired for cylindrical phantoms having single or double targets containing indocyanine green (ICG) solutions. The reconstructed images of ICG concentration reflected the true distributions of ICG concentration with a spatial resolution of about 10 mm. In vivo experiments were conducted using a mouse in which an ICG capsule was embedded beneath the skin in the abdomen. The reconstructed image of the ICG concentration again reflected the true distribution of ICG although artifacts due to autofluorescence appeared in the vicinity of the skin. The effectiveness of the total light approach was demonstrated by the phantom and mouse experiments.
Collapse
Affiliation(s)
- Shinpei Okawa
- Department of Mechanical Engineering and Intelligent Systems, University of Electro-Communications, 1-5-1 Chofuga-oka, Chofu, Tokyo 182-8585, Japan
- Currently with the Department of Medical Engineering, National Defense Medical College, 3-2 Namiki, Tokorozawa, Saitama 359-8513, Japan
| | - Akira Yano
- Graduate students of the Department of Mechanical Engineering and Intelligent Systems, University of Electro-Communications, 1-5-1 Chofuga-oka, Chofu, Tokyo 182-8585, Japan
| | - Kazuki Uchida
- Graduate students of the Department of Mechanical Engineering and Intelligent Systems, University of Electro-Communications, 1-5-1 Chofuga-oka, Chofu, Tokyo 182-8585, Japan
| | - Yohei Mitsui
- Graduate students of the Department of Mechanical Engineering and Intelligent Systems, University of Electro-Communications, 1-5-1 Chofuga-oka, Chofu, Tokyo 182-8585, Japan
| | - Masaki Yoshida
- Graduate students of the Department of Mechanical Engineering and Intelligent Systems, University of Electro-Communications, 1-5-1 Chofuga-oka, Chofu, Tokyo 182-8585, Japan
| | - Masashi Takekoshi
- Graduate students of the Department of Mechanical Engineering and Intelligent Systems, University of Electro-Communications, 1-5-1 Chofuga-oka, Chofu, Tokyo 182-8585, Japan
| | - Andhi Marjono
- Graduate students of the Department of Mechanical Engineering and Intelligent Systems, University of Electro-Communications, 1-5-1 Chofuga-oka, Chofu, Tokyo 182-8585, Japan
| | - Feng Gao
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
| | - Yoko Hoshi
- Integrated Neuroscience Research Project, Tokyo Metropolitan Institute of Medical Science, 2-1-6 Kami-kitazawa, Setagaya, Tokyo 156-8506, Japan
| | - Ikuhiro Kida
- Integrated Neuroscience Research Project, Tokyo Metropolitan Institute of Medical Science, 2-1-6 Kami-kitazawa, Setagaya, Tokyo 156-8506, Japan
| | - Kazuto Masamoto
- Center for Frontier Science and Engineering, University of Electro-Communications, 1-5-1 Chofuga-oka, Chofu, Tokyo 182-8585, Japan
| | - Yukio Yamada
- Department of Mechanical Engineering and Intelligent Systems, University of Electro-Communications, 1-5-1 Chofuga-oka, Chofu, Tokyo 182-8585, Japan
| |
Collapse
|
20
|
Zhang W, Wu L, Li J, Yi X, Wang X, Lu Y, Chen W, Zhou Z, Zhang L, Zhao H, Gao F. Combined hemoglobin and fluorescence diffuse optical tomography for breast tumor diagnosis: a pilot study on time-domain methodology. BIOMEDICAL OPTICS EXPRESS 2013; 4:331-48. [PMID: 23412647 PMCID: PMC3567719 DOI: 10.1364/boe.4.000331] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2012] [Revised: 01/21/2013] [Accepted: 01/23/2013] [Indexed: 05/14/2023]
Abstract
A combined time-domain fluorescence and hemoglobin diffuse optical tomography (DOT) system and the image reconstruction methods are proposed for enhancing the reliability of breast-dedicated optical measurement. The system equipped with two pulsed laser diodes at wavelengths of 780 nm and 830 nm that are specific to the peak excitation and emission of the FDA-approved ICG agent, and works with a 4-channel time-correlated single photon counting device to acquire the time-resolved distributions of the light re-emissions at 32 boundary sites of tissues in a tandem serial-to-parallel mode. The simultaneous reconstruction of the two optical (absorption and scattering) and two fluorescent (yield and lifetime) properties are achieved with the respective featured-data algorithms based on the generalized pulse spectrum technique. The performances of the methodology are experimentally assessed on breast-mimicking phantoms for hemoglobin- and fluorescence-DOT alone, as well as for fluorescence-guided hemoglobin-DOT. The results demonstrate the efficacy of improving the accuracy of hemoglobin-DOT based on a priori fluorescence localization.
Collapse
Affiliation(s)
- Wei Zhang
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
| | - Linhui Wu
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
| | - Jiao Li
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
| | - Xi Yi
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
| | - Xin Wang
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
| | - Yiming Lu
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
| | - Weiting Chen
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
| | - Zhongxing Zhou
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin 300072, China
| | - Limin Zhang
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin 300072, China
| | - Huijuan Zhao
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin 300072, China
| | - Feng Gao
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
- Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin 300072, China
| |
Collapse
|
21
|
Ma W, Zhang W, Yi X, Li J, Wu L, Wang X, Zhang L, Zhou Z, Zhao H, Gao F. Time-domain fluorescence-guided diffuse optical tomography based on the third-order simplified harmonics approximation. APPLIED OPTICS 2012; 51:8656-8668. [PMID: 23262607 DOI: 10.1364/ao.51.008656] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2012] [Accepted: 11/15/2012] [Indexed: 06/01/2023]
Abstract
Extensive efforts have been made to integrate diffuse optical tomography (DOT) with other imaging modalities, such as magnetic-resonance imaging and x-ray computerized tomography, for its performance improvement. However, the experimental apparatus is in general intricate and costly due to adoption of the physically distinct radiation regimes. In this study, a time-domain fluorescence-guided DOT methodology that incorporates a priori localization information provided by diffuse fluorescence tomography (DFT) is investigated in an attempt to optimize recovery of the optical property distributions. The methodology is based on a specifically designed multichannel time-correlated single-photon-counting DOT/DFT system as well as a featured-data image reconstruction scheme that is developed within the framework of the generalized pulse spectrum technique and employs the third-order simplified harmonics approximation to the radiative transfer equation as the forward model. We have validated the methodology using phantom experiments and demonstrated that, with the guidance of fluorescence a priori, the quantitativeness and spatial resolution of the recovered optical target can be considerably improved in terms of the absorption and scattering images.
Collapse
Affiliation(s)
- Wenjuan Ma
- College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China
| | | | | | | | | | | | | | | | | | | |
Collapse
|
22
|
Tichauer KM, Holt RW, El-Ghussein F, Zhu Q, Dehghani H, Leblond F, Pogue BW. Imaging workflow and calibration for CT-guided time-domain fluorescence tomography. BIOMEDICAL OPTICS EXPRESS 2011; 2:3021-36. [PMID: 22076264 PMCID: PMC3207372 DOI: 10.1364/boe.2.003021] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2011] [Revised: 08/17/2011] [Accepted: 09/22/2011] [Indexed: 05/20/2023]
Abstract
In this study, several key optimization steps are outlined for a non-contact, time-correlated single photon counting small animal optical tomography system, using simultaneous collection of both fluorescence and transmittance data. The system is presented for time-domain image reconstruction in vivo, illustrating the sensitivity from single photon counting and the calibration steps needed to accurately process the data. In particular, laser time- and amplitude-referencing, detector and filter calibrations, and collection of a suitable instrument response function are all presented in the context of time-domain fluorescence tomography and a fully automated workflow is described. Preliminary phantom time-domain reconstructed images demonstrate the fidelity of the workflow for fluorescence tomography based on signal from multiple time gates.
Collapse
Affiliation(s)
- Kenneth M. Tichauer
- Thayer School of Engineering, Dartmouth College, 8000 Cummings Hall, Hanover, NH 03755, USA
| | - Robert W. Holt
- Department of Physics and Astronomy, Dartmouth College, NH 03755, USA
| | - Fadi El-Ghussein
- Thayer School of Engineering, Dartmouth College, 8000 Cummings Hall, Hanover, NH 03755, USA
| | - Qun Zhu
- School of Computer Science, University of Birmingham, Birmingham, B15 2TT, UK
| | - Hamid Dehghani
- School of Computer Science, University of Birmingham, Birmingham, B15 2TT, UK
| | - Frederic Leblond
- Thayer School of Engineering, Dartmouth College, 8000 Cummings Hall, Hanover, NH 03755, USA
| | - Brian W. Pogue
- Thayer School of Engineering, Dartmouth College, 8000 Cummings Hall, Hanover, NH 03755, USA
- Department of Physics and Astronomy, Dartmouth College, NH 03755, USA
| |
Collapse
|
23
|
Lin Y, Ghijsen MT, Gao H, Liu N, Nalcioglu O, Gulsen G. A photo-multiplier tube-based hybrid MRI and frequency domain fluorescence tomography system for small animal imaging. Phys Med Biol 2011; 56:4731-47. [PMID: 21753235 PMCID: PMC3961472 DOI: 10.1088/0031-9155/56/15/007] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Fluorescence tomography (FT) is a promising molecular imaging technique that can spatially resolve both fluorophore concentration and lifetime parameters. However, recovered fluorophore parameters highly depend on the size and depth of the object due to the ill-posedness of the FT inverse problem. Structural a priori information from another high spatial resolution imaging modality has been demonstrated to significantly improve FT reconstruction accuracy. In this study, we have constructed a combined magnetic resonance imaging (MRI) and FT system for small animal imaging. A photo-multiplier tube is used as the detector to acquire frequency domain FT measurements. This is the first MR-compatible time-resolved FT system that can reconstruct both fluorescence concentration and lifetime maps simultaneously. The performance of the hybrid system is evaluated with phantom studies. Two different fluorophores, indocyanine green and 3-3' diethylthiatricarbocyanine iodide, which have similar excitation and emission spectra but different lifetimes, are utilized. The fluorescence concentration and lifetime maps are both reconstructed with and without the structural a priori information obtained from MRI for comparison. We show that the hybrid system can accurately recover both fluorescence intensity and lifetime within 10% error for two 4.2 mm-diameter cylindrical objects embedded in a 38 mm-diameter cylindrical phantom when MRI structural a priori information is utilized.
Collapse
Affiliation(s)
- Y Lin
- Tu and Yuen Center for Functional Onco Imaging, University of California, Irvine, CA, 92697, USA
| | - M T Ghijsen
- Tu and Yuen Center for Functional Onco Imaging, University of California, Irvine, CA, 92697, USA
| | - H Gao
- Department of Mathematics, University of California, Los Angeles, CA 90095, USA
| | - N Liu
- Tu and Yuen Center for Functional Onco Imaging, University of California, Irvine, CA, 92697, USA
| | - O Nalcioglu
- Tu and Yuen Center for Functional Onco Imaging, University of California, Irvine, CA, 92697, USA
- Department of Cogno-Mechatronics Engineering, Pusan National University, Pusan, Korea
| | - G Gulsen
- Tu and Yuen Center for Functional Onco Imaging, University of California, Irvine, CA, 92697, USA
| |
Collapse
|
24
|
Laidevant A, Hervé L, Debourdeau M, Boutet J, Grenier N, Dinten JM. Fluorescence time-resolved imaging system embedded in an ultrasound prostate probe. BIOMEDICAL OPTICS EXPRESS 2010; 2:194-206. [PMID: 21326649 PMCID: PMC3028494 DOI: 10.1364/boe.2.000194] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2010] [Revised: 12/10/2010] [Accepted: 12/20/2010] [Indexed: 05/03/2023]
Abstract
Ultrasound imaging (US) of the prostate has a low specificity to distinguish tumors from the surrounding tissues. This limitation leads to systematic biopsies. Fluorescent diffuse optical imaging may represent an innovative approach to guide biopsies to tumors marked with high specificity contrast agents and therefore enable an early detection of prostate cancer. This article describes a time-resolved optical system embedded in a transrectal US probe, as well as the fluorescence reconstruction method and its performance. Optical measurements were performed using a pulsed laser, optical fibers and a time-resolved detection system. A novel fast reconstruction method was derived and used to locate a 45 µL ICG fluorescent inclusion at a concentration of 10 µM, in a liquid prostate phantom. Very high location accuracy (0.15 cm) was achieved after reconstruction, for different positions of the inclusion, in the three directions of space. The repeatability, tested with ten sequential measurements, was of the same order of magnitude. Influence of the input parameters (optical properties and lifetime) is presented. These results confirm the feasibility of using optical imaging for prostate guided biopsies.
Collapse
Affiliation(s)
- Aurélie Laidevant
- CEA-LETI, MINATEC, 17 rue des Martyrs, 38054 Grenoble Cedex 9, France
| | - Lionel Hervé
- CEA-LETI, MINATEC, 17 rue des Martyrs, 38054 Grenoble Cedex 9, France
| | | | - Jérôme Boutet
- CEA-LETI, MINATEC, 17 rue des Martyrs, 38054 Grenoble Cedex 9, France
| | - Nicolas Grenier
- Service d'Imagerie Diagnostique et Interventionnelle de l'Adulte, Groupe Hospitalier Pellegrin, Place Amélie Raba-Léon, 33076 BORDEAUX Cedex, France
| | - Jean-Marc Dinten
- CEA-LETI, MINATEC, 17 rue des Martyrs, 38054 Grenoble Cedex 9, France
| |
Collapse
|
25
|
Soloviev VY, D'Andrea C, Mohan PS, Valentini G, Cubeddu R, Arridge SR. Fluorescence lifetime optical tomography with Discontinuous Galerkin discretisation scheme. BIOMEDICAL OPTICS EXPRESS 2010; 1:998-1013. [PMID: 21258525 PMCID: PMC3018046 DOI: 10.1364/boe.1.000998] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2010] [Revised: 09/07/2010] [Accepted: 09/12/2010] [Indexed: 05/23/2023]
Abstract
We develop discontinuous Galerkin framework for solving direct and inverse problems in fluorescence diffusion optical tomography in turbid media. We show the advantages and the disadvantages of this method by comparing it with previously developed framework based on the finite volume discretization. The reconstruction algorithm was used with time-gated experimental dataset acquired by imaging a highly scattering cylindrical phantom concealing small fluorescent tubes. Optical parameters, quantum yield and lifetime were simultaneously reconstructed. Reconstruction results are presented and discussed.
Collapse
Affiliation(s)
- Vadim Y. Soloviev
- Departments of Computer Science, University College London, Gower Street, London WC1E 6BT, UK
| | - Cosimo D'Andrea
- Centre for Nano Science and Technology of Italian Institute of Technology (IIT), Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| | - P. Surya Mohan
- Departments of Computer Science, University College London, Gower Street, London WC1E 6BT, UK
| | - Gianluca Valentini
- Istituto di Fotonica e Nanotecnologie (IFN-CNR), Italian Institute of Technology (IIT), Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, I-20133 Milano, Italy
| | - Rinaldo Cubeddu
- Istituto di Fotonica e Nanotecnologie (IFN-CNR), Italian Institute of Technology (IIT), Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, I-20133 Milano, Italy
| | - Simon R. Arridge
- Departments of Computer Science, University College London, Gower Street, London WC1E 6BT, UK
| |
Collapse
|