1
|
Williams E, Minesinger K, Gallagher H, Stefanson JR, Bridges N, Jackson N, Stark V, Coto J, Rajguru S, Yankaskas K, Rogers R, Hoffer ME. Examining the utility of near infrared light as pre-exposure therapy to mitigate temporary noise-induced hearing loss in humans. Front Neurol 2024; 15:1366239. [PMID: 38711557 PMCID: PMC11072974 DOI: 10.3389/fneur.2024.1366239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Accepted: 04/04/2024] [Indexed: 05/08/2024] Open
Abstract
Introduction This study sought to determine the effect of Occupational Safety and Health Administration (OSHA) compliant noise on auditory health and assess whether pre-noise near infrared (NIR) light therapy can mitigate the effects of noise exposure. Methods Over four visits, participants (n = 30, NCT#: 03834714) with normal hearing completed baseline hearing health assessments followed by exposure to open ear, continuous pink noise at 94 dBA for 15 min. Immediately thereafter, post-noise hearing tests at 3000, 4000, and 6000 Hz and distortion product otoacoustic emissions (DPOAEs) were conducted along with the Modified Rhyme Test (MRT), Masking Level Difference Test (MLD), and Fixed Level Frequency Tests (FLFT) [collectively referred to as the Central and Peripheral Auditory Test Battery (CPATB)] to acquire baseline noise sensitivity profiles. Participants were then randomized to either Active or Sham NIR light therapy for 30 min binaurally to conclude Visit 1. Visit 2 (≥24 and ≤ 48 h from Visit 1) began with an additional 30-min session of Active NIR light therapy or Sham followed by repeat CPATB testing and noise exposure. Post-noise testing was again conducted immediately after noise exposure to assess the effect of NIR light therapy. The remaining visits were conducted following ≥2 weeks of noise rest in a cross-over design (i.e., those who had received Active NIR light therapy in Visits 1 and 2 received Sham therapy in Visits 3 and 4). Results Recovery hearing tests and DPOAEs were completed at the end of each visit. Participants experienced temporary threshold shifts (TTS) immediately following noise exposure, with a mean shift of 6.79 dB HL (±6.25), 10.61 dB HL (±6.89), and 7.30 dB HL (±7.25) at 3000, 4000, and 6000 Hz, respectively, though all thresholds returned to baseline at 3000, 4000, and 6000 Hz within 75 min of noise exposure. Paradoxically, Active NIR light therapy threshold shifts were statistically higher than Sham therapy at 3000 Hz (p = 0.04), but no other differences were observed at the other frequencies tested. An age sub-analysis demonstrated that TTS among younger adults were generally larger in the Sham therapy group versus Active therapy, though this was not statistically different. There were no differences in CPATB test results across Active or Sham groups. Finally, we observed no changes in auditory function or central processing following noise exposure, suggestive of healthy and resilient inner ears. Conclusion In this study, locally administered NIR prior to noise exposure did not induce a significant protective effect in mitigating noise-induced TTS. Further exploration is needed to implement effective dosage and administration for this promising otoprotective therapy.
Collapse
Affiliation(s)
- Erin Williams
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, United States
- Department of Neurological Surgery, University of Miami Miller School of Medicine, Miami, FL, United States
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL, United States
| | - Kayla Minesinger
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, United States
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL, United States
| | - Hilary Gallagher
- Air Force Research Laboratory, 711th Human Performance Wing, Airman Systems Directorate, Dayton, OH, United States
| | - J. R. Stefanson
- U.S. Army Aeromedical Research Laboratory, Fort Rucker, AL, United States
| | - Nathaniel Bridges
- Air Force Research Laboratory, 711th Human Performance Wing, Airman Systems Directorate, Dayton, OH, United States
| | - Natalie Jackson
- Oak Ridge Institute for Science and Education, Oak Ridge, TN, United States
| | - Valerie Stark
- University of Miami Miller School of Medicine, Miami, FL, United States
| | - Jennifer Coto
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, United States
| | - Suhrud Rajguru
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, United States
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL, United States
| | | | - Rick Rogers
- BioInnovations Institute, Natick, MA, United States
| | - Michael E. Hoffer
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL, United States
- Department of Neurological Surgery, University of Miami Miller School of Medicine, Miami, FL, United States
| |
Collapse
|
2
|
Rank EA, Agneter A, Schmoll T, Leitgeb RA, Drexler W. Miniaturizing optical coherence tomography. TRANSLATIONAL BIOPHOTONICS 2022. [DOI: 10.1002/tbio.202100007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Affiliation(s)
- Elisabet A. Rank
- Center for Medical Physics and Biomedical Engineering Medical University of Vienna Vienna Austria
| | - Anja Agneter
- Center for Medical Physics and Biomedical Engineering Medical University of Vienna Vienna Austria
| | - Tilman Schmoll
- Center for Medical Physics and Biomedical Engineering Medical University of Vienna Vienna Austria
- Carl Zeiss Meditec, Inc. Dublin California USA
| | - Rainer A. Leitgeb
- Center for Medical Physics and Biomedical Engineering Medical University of Vienna Vienna Austria
| | - Wolfgang Drexler
- Center for Medical Physics and Biomedical Engineering Medical University of Vienna Vienna Austria
| |
Collapse
|
3
|
Leitgeb R, Placzek F, Rank E, Krainz L, Haindl R, Li Q, Liu M, Andreana M, Unterhuber A, Schmoll T, Drexler W. Enhanced medical diagnosis for dOCTors: a perspective of optical coherence tomography. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-210150-PER. [PMID: 34672145 PMCID: PMC8528212 DOI: 10.1117/1.jbo.26.10.100601] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 09/23/2021] [Indexed: 05/17/2023]
Abstract
SIGNIFICANCE After three decades, more than 75,000 publications, tens of companies being involved in its commercialization, and a global market perspective of about USD 1.5 billion in 2023, optical coherence tomography (OCT) has become one of the fastest successfully translated imaging techniques with substantial clinical and economic impacts and acceptance. AIM Our perspective focuses on disruptive forward-looking innovations and key technologies to further boost OCT performance and therefore enable significantly enhanced medical diagnosis. APPROACH A comprehensive review of state-of-the-art accomplishments in OCT has been performed. RESULTS The most disruptive future OCT innovations include imaging resolution and speed (single-beam raster scanning versus parallelization) improvement, new implementations for dual modality or even multimodality systems, and using endogenous or exogenous contrast in these hybrid OCT systems targeting molecular and metabolic imaging. Aside from OCT angiography, no other functional or contrast enhancing OCT extension has accomplished comparable clinical and commercial impacts. Some more recently developed extensions, e.g., optical coherence elastography, dynamic contrast OCT, optoretinography, and artificial intelligence enhanced OCT are also considered with high potential for the future. In addition, OCT miniaturization for portable, compact, handheld, and/or cost-effective capsule-based OCT applications, home-OCT, and self-OCT systems based on micro-optic assemblies or photonic integrated circuits will revolutionize new applications and availability in the near future. Finally, clinical translation of OCT including medical device regulatory challenges will continue to be absolutely essential. CONCLUSIONS With its exquisite non-invasive, micrometer resolution depth sectioning capability, OCT has especially revolutionized ophthalmic diagnosis and hence is the fastest adopted imaging technology in the history of ophthalmology. Nonetheless, OCT has not been completely exploited and has substantial growth potential-in academics as well as in industry. This applies not only to the ophthalmic application field, but also especially to the original motivation of OCT to enable optical biopsy, i.e., the in situ imaging of tissue microstructure with a resolution approaching that of histology but without the need for tissue excision.
Collapse
Affiliation(s)
- Rainer Leitgeb
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
- Medical University of Vienna, Christian Doppler Laboratory OPTRAMED, Vienna, Austria
| | - Fabian Placzek
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Elisabet Rank
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Lisa Krainz
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Richard Haindl
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Qian Li
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Mengyang Liu
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Marco Andreana
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Angelika Unterhuber
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
| | - Tilman Schmoll
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
- Carl Zeiss Meditec, Inc., Dublin, California, United States
| | - Wolfgang Drexler
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Vienna, Austria
- Address all correspondence to Wolfgang Drexler,
| |
Collapse
|
4
|
Gisselsson-Solén M, Tähtinen PA, Ryan AF, Mulay A, Kariya S, Schilder AG, Valdez TA, Brown S, Nolan RM, Hermansson A, van Ingen G, Marom T. Panel 1: Biotechnology, biomedical engineering and new models of otitis media. Int J Pediatr Otorhinolaryngol 2020; 130 Suppl 1:109833. [PMID: 31901291 PMCID: PMC7176743 DOI: 10.1016/j.ijporl.2019.109833] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To summarize recently published key articles on the topics of biomedical engineering, biotechnology and new models in relation to otitis media (OM). DATA SOURCES Electronic databases: PubMed, Ovid Medline, Cochrane Library and Clinical Evidence (BMJ Publishing). REVIEW METHODS Articles on biomedical engineering, biotechnology, material science, mechanical and animal models in OM published between May 2015 and May 2019 were identified and subjected to review. A total of 132 articles were ultimately included. RESULTS New imaging technologies for the tympanic membrane (TM) and the middle ear cavity are being developed to assess TM thickness, identify biofilms and differentiate types of middle ear effusions. Artificial intelligence (AI) has been applied to train software programs to diagnose OM with a high degree of certainty. Genetically modified mice models for OM have further investigated what predisposes some individuals to OM and consequent hearing loss. New vaccine candidates protecting against major otopathogens are being explored and developed, especially combined vaccines, targeting more than one pathogen. Transcutaneous vaccination against non-typeable Haemophilus influenzae has been successfully tried in a chinchilla model. In terms of treatment, novel technologies for trans-tympanic drug delivery are entering the clinical domain. Various growth factors and grafting materials aimed at improving healing of TM perforations show promising results in animal models. CONCLUSION New technologies and AI applications to improve the diagnosis of OM have shown promise in pre-clinical models and are gradually entering the clinical domain. So are novel vaccines and drug delivery approaches that may allow local treatment of OM. IMPLICATIONS FOR PRACTICE New diagnostic methods, potential vaccine candidates and the novel trans-tympanic drug delivery show promising results, but are not yet adapted to clinical use.
Collapse
Affiliation(s)
- Marie Gisselsson-Solén
- Department of Clinical Sciences, Division of Otorhinolaryngology, Head and Neck Surgery, Lund University Hospital, Lund, Sweden
| | - Paula A. Tähtinen
- Department of Pediatrics and Adolescent Medicine, Turku University Hospital and University of Turku, Turku, Finland
| | - Allen F. Ryan
- Division of Otolaryngology, Department of Surgery, University of California, San Diego, La Jolla, CA, USA,San Diego Veterans Affairs Healthcare System, Research Department, San Diego, CA, USA
| | - Apoorva Mulay
- The Stripp Lab, Pulmonary Department, Cedars Sinai Medical Center, Los Angeles, CA, USA
| | - Shin Kariya
- Department of Otolaryngology-Head and Neck Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan
| | - Anne G.M. Schilder
- EvidENT, Ear Institute, University College London, London, UK,National Institute for Health Research University College London Biomedical Research Centre, London, UK,Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Tulio A. Valdez
- Department of Otolaryngology Head & Neck Surgery, Stanford University, Palo Alto, CA, USA
| | - Steve Brown
- MRC Harwell Institute, Mammalian Genetics Unit, Harwell Campus, Oxfordshire, UK
| | | | - Ann Hermansson
- Department of Clinical Sciences, Division of Otorhinolaryngology, Head and Neck Surgery, Lund University Hospital, Lund, Sweden
| | - Gijs van Ingen
- Department of Otolaryngology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Tal Marom
- Department of Otolaryngology-Head and Neck Surgery, Samson Assuta Ashdod University Hospital, Faculty of Health Sciences Ben Gurion University, Ashdod, Israel.
| |
Collapse
|
5
|
Almog IF, Chen F, Senova S, Fomenko A, Gondard E, Sacher WD, Lozano AM, Poon JKS. Full-field swept-source optical coherence tomography and neural tissue classification for deep brain imaging. JOURNAL OF BIOPHOTONICS 2020; 13:e201960083. [PMID: 31710771 PMCID: PMC7065632 DOI: 10.1002/jbio.201960083] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2019] [Revised: 10/19/2019] [Accepted: 11/06/2019] [Indexed: 05/28/2023]
Abstract
Optical coherence tomography can differentiate brain regions with intrinsic contrast and at a micron scale resolution. Such a device can be particularly useful as a real-time neurosurgical guidance tool. We present, to our knowledge, the first full-field swept-source optical coherence tomography system operating near a wavelength of 1310 nm. The proof-of-concept system was integrated with an endoscopic probe tip, which is compatible with deep brain stimulation keyhole neurosurgery. Neuroimaging experiments were performed on ex vivo brain tissues and in vivo in rat brains. Using classification algorithms involving texture features and optical attenuation, images were successfully classified into three brain tissue types.
Collapse
Affiliation(s)
- Ilan Felts Almog
- Edward S. Rogers Sr. Department of Electrical and Computer EngineeringUniversity of TorontoTorontoOntarioCanada
- Krembil Research InstituteToronto Western HospitalTorontoOntarioCanada
| | - Fu‐Der Chen
- Edward S. Rogers Sr. Department of Electrical and Computer EngineeringUniversity of TorontoTorontoOntarioCanada
- Krembil Research InstituteToronto Western HospitalTorontoOntarioCanada
| | - Suhan Senova
- Krembil Research InstituteToronto Western HospitalTorontoOntarioCanada
- Department of NeurosurgeryCentre Hospitalier Universitaire Henri‐Mondor, APHPCréteilFrance
- INSERM Unit 955, Institut Mondor de Recherche Biomédicale, Université Paris‐EstCréteilFrance
| | - Anton Fomenko
- Krembil Research InstituteToronto Western HospitalTorontoOntarioCanada
| | - Elise Gondard
- Krembil Research InstituteToronto Western HospitalTorontoOntarioCanada
| | - Wesley D. Sacher
- Edward S. Rogers Sr. Department of Electrical and Computer EngineeringUniversity of TorontoTorontoOntarioCanada
- Max Planck Institute of Microstructure PhysicsHalleGermany
| | - Andres M. Lozano
- Krembil Research InstituteToronto Western HospitalTorontoOntarioCanada
- Division of Neurosurgery, Department of SurgeryToronto Western HospitalTorontoOntarioCanada
| | - Joyce K. S. Poon
- Edward S. Rogers Sr. Department of Electrical and Computer EngineeringUniversity of TorontoTorontoOntarioCanada
- Krembil Research InstituteToronto Western HospitalTorontoOntarioCanada
- Max Planck Institute of Microstructure PhysicsHalleGermany
| |
Collapse
|
6
|
Preciado D, Nolan RM, Joshi R, Krakovsky GM, Zhang A, Pudik NA, Kumar NK, Shelton RL, Boppart SA, Bauman NM. Otitis Media Middle Ear Effusion Identification and Characterization Using an Optical Coherence Tomography Otoscope. Otolaryngol Head Neck Surg 2020; 162:367-374. [PMID: 31959053 DOI: 10.1177/0194599819900762] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
OBJECTIVE To determine the feasibility of detecting and differentiating middle ear effusions (MEEs) using an optical coherence tomography (OCT) otoscope. STUDY DESIGN Cross-sectional study. SETTING US tertiary care children's hospital. SUBJECTS AND METHODS Seventy pediatric patients undergoing tympanostomy tube placement were preoperatively imaged using an OCT otoscope. A blinded reader quiz was conducted using 24 readers from 4 groups of tiered medical expertise. The primary outcome assessed was reader ability to detect presence/absence of MEE. A secondary outcome assessed was reader ability to differentiate serous vs nonserous MEE. RESULTS OCT image data sets were analyzed from 45 of 70 total subjects. Blinded reader analysis of an OCT data subset for detection of MEE resulted in 90.6% accuracy, 90.9% sensitivity, 90.2% specificity, and intra/interreader agreement of 92.9% and 87.1%, respectively. Differentiating MEE type, reader identification of nonserous MEE had 70.8% accuracy, 53.6% sensitivity, 80.1% specificity, and intra/interreader agreement of 82.9% and 75.1%, respectively. Multivariate analysis revealed that age was the strongest predictor of OCT quality. The mean age of subjects with quality OCT was 5.01 years (n = 45), compared to 2.54 years (n = 25) in the remaining subjects imaged (P = .0028). The ability to capture quality images improved over time, from 50% to 69.4% over the study period. CONCLUSION OCT otoscopy shows promise for facilitating accurate MEE detection. The imageability with the prototype device was affected by age, with older children being easier to image, similar to current ear diagnostic technologies.
Collapse
Affiliation(s)
- Diego Preciado
- Division of Pediatric Otolaryngology, Children's National Health System (CNHS), Washington, DC, USA.,Sheikh Zayed Institute, CNHS, Washington, DC, USA
| | | | - Radhika Joshi
- Division of Pediatric Otolaryngology, Children's National Health System (CNHS), Washington, DC, USA.,Sheikh Zayed Institute, CNHS, Washington, DC, USA
| | - Gina M Krakovsky
- Division of Pediatric Otolaryngology, Children's National Health System (CNHS), Washington, DC, USA
| | | | | | | | | | | | - Nancy M Bauman
- Division of Pediatric Otolaryngology, Children's National Health System (CNHS), Washington, DC, USA
| |
Collapse
|
7
|
Kirsten L, Schindler M, Morgenstern J, Erkkilä MT, Golde J, Walther J, Rottmann P, Kemper M, Bornitz M, Neudert M, Zahnert T, Koch E. Endoscopic optical coherence tomography with wide field-of-view for the morphological and functional assessment of the human tympanic membrane. JOURNAL OF BIOMEDICAL OPTICS 2018; 24:1-11. [PMID: 30516037 PMCID: PMC6975278 DOI: 10.1117/1.jbo.24.3.031017] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2018] [Accepted: 11/05/2018] [Indexed: 05/25/2023]
Abstract
An endoscopic optical coherence tomography (OCT) system with a wide field-of-view of 8 mm is presented, which combines the image capability of endoscopic imaging at the middle ear with the advantages of functional OCT imaging, allowing a morphological and functional assessment of the human tympanic membrane. The endoscopic tube has a diameter of 3.5 mm and contains gradient-index optics for simultaneous forward-viewing OCT and video endoscopy. The endoscope allows the three-dimensional visualization of nearly the entire tympanic membrane. In addition, the oscillation of the tympanic membrane is measured spatially resolved and in the frequency range between 500 Hz and 5 kHz with 125 Hz resolution, which is realized by phase-resolved Doppler OCT imaging during acoustical excitation with chirp signals. The applicability of the OCT system is demonstrated in vivo. Due to the fast image acquisition, structural and functional measurements are only slightly affected by motion artifacts.
Collapse
Affiliation(s)
- Lars Kirsten
- Technische Universität Dresden, Carl Gustav Carus Faculty of Medicine, Anesthesiology and Critical Care Medicine, Clinical Sensoring and Monitoring, Dresden, Germany
| | - Martin Schindler
- Technische Universität Dresden, Carl Gustav Carus Faculty of Medicine, Anesthesiology and Critical Care Medicine, Clinical Sensoring and Monitoring, Dresden, Germany
| | - Joseph Morgenstern
- Technische Universität Dresden, Carl Gustav Carus Faculty of Medicine, Otorhinolaryngology, Dresden, Germany
| | - Mikael Timo Erkkilä
- Technische Universität Dresden, Carl Gustav Carus Faculty of Medicine, Anesthesiology and Critical Care Medicine, Clinical Sensoring and Monitoring, Dresden, Germany
| | - Jonas Golde
- Technische Universität Dresden, Carl Gustav Carus Faculty of Medicine, Anesthesiology and Critical Care Medicine, Clinical Sensoring and Monitoring, Dresden, Germany
| | - Julia Walther
- Technische Universität Dresden, Carl Gustav Carus Faculty of Medicine, Anesthesiology and Critical Care Medicine, Clinical Sensoring and Monitoring, Dresden, Germany
- Technische Universität Dresden, Carl Gustav Carus Faculty of Medicine, Medical Physics and Biomedical Engineering, Dresden, Germany
| | - Pascal Rottmann
- Technische Universität Dresden, Carl Gustav Carus Faculty of Medicine, Anesthesiology and Critical Care Medicine, Clinical Sensoring and Monitoring, Dresden, Germany
| | - Max Kemper
- Technische Universität Dresden, Carl Gustav Carus Faculty of Medicine, Otorhinolaryngology, Dresden, Germany
| | - Matthias Bornitz
- Technische Universität Dresden, Carl Gustav Carus Faculty of Medicine, Otorhinolaryngology, Dresden, Germany
| | - Marcus Neudert
- Technische Universität Dresden, Carl Gustav Carus Faculty of Medicine, Otorhinolaryngology, Dresden, Germany
| | - Thomas Zahnert
- Technische Universität Dresden, Carl Gustav Carus Faculty of Medicine, Otorhinolaryngology, Dresden, Germany
| | - Edmund Koch
- Technische Universität Dresden, Carl Gustav Carus Faculty of Medicine, Anesthesiology and Critical Care Medicine, Clinical Sensoring and Monitoring, Dresden, Germany
| |
Collapse
|
8
|
Lee J, Wijesinghe RE, Jeon D, Kim P, Choung YH, Jang JH, Jeon M, Kim J. Clinical Utility of Intraoperative Tympanomastoidectomy Assessment Using a Surgical Microscope Integrated with an Optical Coherence Tomography. Sci Rep 2018; 8:17432. [PMID: 30479360 PMCID: PMC6258704 DOI: 10.1038/s41598-018-35563-5] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2018] [Accepted: 10/29/2018] [Indexed: 12/15/2022] Open
Abstract
Significant technical and optical advances are required for intraoperative optical coherence tomography (OCT) to be utilized during otological surgeries. Integrating OCT with surgical microscopy makes it possible to evaluate soft tissue in real-time and at a high resolution. Herein, we describe an augmented-reality, intraoperative OCT/microscope system with an extended working distance of 280 mm, providing more space for surgical manipulation than conventional techniques. We initially performed ex vivo experiments to evaluate system performance. In addition, we validated the system by performing preliminary clinical assessments of tympanomastoidectomy outcomes in six patients with chronic otitis media. The system evaluated residual inflammation in the region-of-interest of the mastoid bone. Most importantly, the system intraoperatively revealed the connection between the graft and the remnant tympanic membrane. The extended working distance allows otological surgeons to evaluate the status of both the mastoid bone and tympanic membrane during manipulation, affording full intraoperative imaging.
Collapse
Affiliation(s)
- Jaeyul Lee
- School of Electronics Engineering, College of IT Engineering, Kyungpook National University, 80 Daehak-ro, Buk-gu, Daegu, 41566, Republic of Korea
| | - Ruchire Eranga Wijesinghe
- Department of Biomedical Engineering, College of Engineering, Kyungil University, 50, Gamasil-gil, Hayang-eup, Gyeongsan-si, Gyeongsangbuk-do, 38428, Republic of Korea
| | - Deokmin Jeon
- School of Electronics Engineering, College of IT Engineering, Kyungpook National University, 80 Daehak-ro, Buk-gu, Daegu, 41566, Republic of Korea
| | - Pilun Kim
- School of Electronics Engineering, College of IT Engineering, Kyungpook National University, 80 Daehak-ro, Buk-gu, Daegu, 41566, Republic of Korea
| | - Yun-Hoon Choung
- Department of Otolaryngology, School of Medicine, Ajou University, 164 World cup-ro, Yeongtong-gu, Suwon, Gyeunggi-do, 16499, Republic of Korea
| | - Jeong Hun Jang
- Department of Otolaryngology, School of Medicine, Ajou University, 164 World cup-ro, Yeongtong-gu, Suwon, Gyeunggi-do, 16499, Republic of Korea.
| | - Mansik Jeon
- School of Electronics Engineering, College of IT Engineering, Kyungpook National University, 80 Daehak-ro, Buk-gu, Daegu, 41566, Republic of Korea
| | - Jeehyun Kim
- School of Electronics Engineering, College of IT Engineering, Kyungpook National University, 80 Daehak-ro, Buk-gu, Daegu, 41566, Republic of Korea.
| |
Collapse
|
9
|
Multiple Wavelength Optical Coherence Tomography Assessments for Enhanced Ex Vivo Intra-Cochlear Microstructural Visualization. ELECTRONICS 2018. [DOI: 10.3390/electronics7080133] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The precise identification of intra-cochlear microstructures is an essential otorhinolaryngological requirement to diagnose the progression of cochlea related diseases. Thus, we demonstrated an experimental procedure to investigate the most optimal wavelength range, which can enhance the visualization of ex vivo intra-cochlear microstructures using multiple wavelengths (i.e., 860 nm, 1060 nm, and 1300 nm) based optical coherence tomography (OCT) systems. The high-resolution tomograms, volumetric, and quantitative evaluations obtained from Basilar membrane, organ of Corti, and scala vestibule regions revealed complementary comparisons between the aforementioned three distinct wavelengths based OCT systems. Compared to 860 nm and 1300 nm wavelengths, 1060 nm wavelength OCT was discovered to be an appropriate wavelength range verifying the simultaneously obtainable high-resolution and reasonable depth range visualization of intra-cochlear microstructures. Therefore, the implementation of 1060 nm OCT can minimize the necessity of two distinct OCT systems. Moreover, the results suggest that the performed qualitative and quantitative analysis procedure can be used as a powerful tool to explore further anatomical structures of the cochlea for future studies in otorhinolaryngology.
Collapse
|
10
|
Tan HEI, Santa Maria PL, Wijesinghe P, Francis Kennedy B, Allardyce BJ, Eikelboom RH, Atlas MD, Dilley RJ. Optical Coherence Tomography of the Tympanic Membrane and Middle Ear: A Review. Otolaryngol Head Neck Surg 2018; 159:424-438. [PMID: 29787354 DOI: 10.1177/0194599818775711] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Objective To evaluate the recent developments in optical coherence tomography (OCT) for tympanic membrane (TM) and middle ear (ME) imaging and to identify what further development is required for the technology to be integrated into common clinical use. Data Sources PubMed, Embase, Google Scholar, Scopus, and Web of Science. Review Methods A comprehensive literature search was performed for English language articles published from January 1966 to January 2018 with the keywords "tympanic membrane or middle ear,""optical coherence tomography," and "imaging." Conclusion Conventional imaging techniques cannot adequately resolve the microscale features of TM and ME, sometimes necessitating diagnostic exploratory surgery in challenging otologic pathology. As a high-resolution noninvasive imaging technique, OCT offers promise as a diagnostic aid for otologic conditions, such as otitis media, cholesteatoma, and conductive hearing loss. Using OCT vibrometry to image the nanoscale vibrations of the TM and ME as they conduct acoustic waves may detect the location of ossicular chain dysfunction and differentiate between stapes fixation and incus-stapes discontinuity. The capacity of OCT to image depth and thickness at high resolution allows 3-dimensional volumetric reconstruction of the ME and has potential use for reconstructive tympanoplasty planning and the follow-up of ossicular prostheses. Implications for Practice To achieve common clinical use beyond these initial discoveries, future in vivo imaging devices must feature low-cost probe or endoscopic designs and faster imaging speeds and demonstrate superior diagnostic utility to computed tomography and magnetic resonance imaging. While such technology has been available for OCT, its translation requires focused development through a close collaboration between engineers and clinicians.
Collapse
Affiliation(s)
- Hsern Ern Ivan Tan
- 1 Ear Science Institute Australia, Subiaco, Australia.,2 Ear Sciences Centre, School of Medicine, The University of Western Australia, Nedlands, Australia.,3 Department of Otolaryngology-Head and Neck Surgery, Sir Charles Gairdner Hospital, Perth, Australia
| | - Peter Luke Santa Maria
- 1 Ear Science Institute Australia, Subiaco, Australia.,2 Ear Sciences Centre, School of Medicine, The University of Western Australia, Nedlands, Australia.,4 Department of Otolaryngology-Head and Neck Surgery, Stanford University, Stanford, California, USA
| | - Philip Wijesinghe
- 5 BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre; Centre for Medical Research, The University of Western Australia, Nedlands, Australia.,6 Department of Electrical, Electronic, and Computer Engineering, School of Engineering, The University of Western Australia, Nedlands, Australia
| | - Brendan Francis Kennedy
- 5 BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre; Centre for Medical Research, The University of Western Australia, Nedlands, Australia.,6 Department of Electrical, Electronic, and Computer Engineering, School of Engineering, The University of Western Australia, Nedlands, Australia
| | | | - Robert Henry Eikelboom
- 1 Ear Science Institute Australia, Subiaco, Australia.,2 Ear Sciences Centre, School of Medicine, The University of Western Australia, Nedlands, Australia.,8 Department of Speech Language Pathology and Audiology, University of Pretoria, Pretoria, South Africa
| | - Marcus David Atlas
- 1 Ear Science Institute Australia, Subiaco, Australia.,2 Ear Sciences Centre, School of Medicine, The University of Western Australia, Nedlands, Australia
| | - Rodney James Dilley
- 1 Ear Science Institute Australia, Subiaco, Australia.,2 Ear Sciences Centre, School of Medicine, The University of Western Australia, Nedlands, Australia
| |
Collapse
|
11
|
Catrysse PB, Irsch K, Javidi B, Preza C, Testorf M, Zalevsky Z. Modern imaging: introduction to the feature issue. APPLIED OPTICS 2017; 56:MI1-MI2. [PMID: 28375372 DOI: 10.1364/ao.56.000mi1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
This special issue of Applied Optics contains selected papers reflecting the various disciplines that are needed for the design, implementation and advancement of imaging technology and systems, and it highlights the state-of-the-art research developments in the areas of modern imaging use.
Collapse
|