1
|
Weinberg G, Weiss U, Katz O. Image scanning lensless fiber-bundle endomicroscopy. OPTICS EXPRESS 2023; 31:37050-37057. [PMID: 38017842 DOI: 10.1364/oe.496369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Accepted: 09/07/2023] [Indexed: 11/30/2023]
Abstract
Fiber-based confocal endomicroscopy has shown great promise for minimally-invasive deep-tissue imaging. Despite its advantages, confocal fiber-bundle endoscopy inherently suffers from undersampling due to the spacing between fiber cores, and low collection efficiency when the target is not in proximity to the distal fiber facet. Here, we demonstrate an adaptation of image-scanning microscopy (ISM) to lensless fiber bundle endoscopy, doubling the spatial sampling frequency and significantly improving collection efficiency. Our approach only requires replacing the confocal detector with a camera. It improves the spatial resolution for targets placed at a distance from the fiber tip, and addresses the fundamental challenge of aliasing/pixelization artifacts.
Collapse
|
2
|
Temma K, Oketani R, Lachmann R, Kubo T, Smith NI, Heintzmann R, Fujita K. Saturated-excitation image scanning microscopy. OPTICS EXPRESS 2022; 30:13825-13838. [PMID: 35472987 DOI: 10.1364/oe.455621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Accepted: 03/27/2022] [Indexed: 06/14/2023]
Abstract
Image scanning microscopy (ISM) overcomes the trade-off between spatial resolution and signal volume in confocal microscopy by rearranging the signal distribution on a two-dimensional detector array to achieve a spatial resolution close to the theoretical limit achievable by infinitesimal pinhole detection without sacrificing the detected signal intensity. In this paper, we improved the spatial resolution of ISM in three dimensions by exploiting saturated excitation (SAX) of fluorescence. We theoretically investigated the imaging properties of ISM, when the fluorescence signals are nonlinearly induced by SAX, and show combined SAX-ISM fluorescence imaging to demonstrate the improvement of the spatial resolution in three dimensions. In addition, we confirmed that the SNR of SAX-ISM imaging of fluorescent beads and biological samples, which is one of the challenges in conventional SAX microscopy, was improved.
Collapse
|
3
|
The Development of Microscopy for Super-Resolution: Confocal Microscopy, and Image Scanning Microscopy. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11198981] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Optical methods of super-resolution microscopy, such as confocal microscopy, structured illumination, nonlinear microscopy, and image scanning microscopy are reviewed. These methods avoid strong invasive interaction with a sample, allowing the observation of delicate biological samples. The meaning of resolution and the basic principles and different approaches to superresolution are discussed.
Collapse
|
4
|
Gopal AA, Kazarine A, Dubach JM, Wiseman PW. Recent advances in nonlinear microscopy: Deep insights and polarized revelations. Int J Biochem Cell Biol 2020; 130:105896. [PMID: 33253831 DOI: 10.1016/j.biocel.2020.105896] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2020] [Revised: 11/12/2020] [Accepted: 11/19/2020] [Indexed: 11/16/2022]
Abstract
Nonlinear microscopy is a technique that utilizes nonlinear interactions between light and matter to image fluorescence and scattering phenomena in biological tissues. Very high peak intensities from focused short pulsed lasers are required for nonlinear excitation due to the extremely low probability of the simultaneous arrival of multiple photons of lower energy to excite fluorophores or interact with selective structures for harmonic generation. Combined with reduced scattering from the utilization of longer wavelengths, the inherent spatial confinement associated with achieving simultaneous arrival of photons within the focal volume enables deep imaging with low out-of-focus background for nonlinear imaging. This review provides an introduction to the different contrast mechanisms available with nonlinear imaging and instrumentation commonly used in nonlinear microscopy. Furthermore, we discuss some recent advances in nonlinear microscopy to extend the imaging penetration depth, conduct histopathological investigations on fresh tissues and examine the molecular order and orientation of molecules using polarization nonlinear microscopy.
Collapse
Affiliation(s)
- A A Gopal
- Center for Systems Biology and Institute for Innovation in Imaging, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA; Department of Chemistry, McGill University, Montreal, Quebec, Canada
| | - A Kazarine
- Department of Chemistry, McGill University, Montreal, Quebec, Canada
| | - J M Dubach
- Center for Systems Biology and Institute for Innovation in Imaging, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA
| | - P W Wiseman
- Department of Chemistry, McGill University, Montreal, Quebec, Canada; Department of Physics, McGill University, Montreal, Quebec, Canada.
| |
Collapse
|
5
|
Koho SV, Slenders E, Tortarolo G, Castello M, Buttafava M, Villa F, Tcarenkova E, Ameloot M, Bianchini P, Sheppard CJR, Diaspro A, Tosi A, Vicidomini G. Two-photon image-scanning microscopy with SPAD array and blind image reconstruction. BIOMEDICAL OPTICS EXPRESS 2020; 11:2905-2924. [PMID: 32637232 DOI: 10.1101/563288] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Revised: 04/20/2020] [Accepted: 04/26/2020] [Indexed: 05/25/2023]
Abstract
Two-photon excitation (2PE) laser scanning microscopy is the imaging modality of choice when one desires to work with thick biological samples. However, its spatial resolution is poor, below confocal laser scanning microscopy. Here, we propose a straightforward implementation of 2PE image scanning microscopy (2PE-ISM) that, by leveraging our recently introduced single-photon avalanche diode (SPAD) array detector and a novel blind image reconstruction method, is shown to enhance the effective resolution, as well as the overall image quality of 2PE microscopy. With our adaptive pixel reassignment procedure ∼1.6 times resolution increase is maintained deep into thick semi-transparent samples. The integration of Fourier ring correlation based semi-blind deconvolution is shown to further enhance the effective resolution by a factor of ∼2 - and automatic background correction is shown to boost the image quality especially in noisy images. Most importantly, our 2PE-ISM implementation requires no calibration measurements or other input from the user, which is an important aspect in terms of day-to-day usability of the technique.
Collapse
Affiliation(s)
- Sami V Koho
- Molecular Microscopy and Spectroscopy, Istituto Italiano di Tecnologia, Genoa, Italy
- University of Turku, Department of Cell Biology and Anatomy, Institute of Biomedicine and Medicity Research Laboratories, Laboratory of Biophysics, Turku, Finland
- These authors contributed equally to this work
| | - Eli Slenders
- Molecular Microscopy and Spectroscopy, Istituto Italiano di Tecnologia, Genoa, Italy
- Hasselt University, Biomedical Research Institute (BIOMED), Diepenbeek, Belgium
- These authors contributed equally to this work
| | - Giorgio Tortarolo
- Molecular Microscopy and Spectroscopy, Istituto Italiano di Tecnologia, Genoa, Italy
- Dipartimento di Informatiche, Bioingegneria, Robotica e Ingegneria dei Sistemi, University of Genoa, Italy
| | - Marco Castello
- Molecular Microscopy and Spectroscopy, Istituto Italiano di Tecnologia, Genoa, Italy
| | - Mauro Buttafava
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | - Federica Villa
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | - Elena Tcarenkova
- Molecular Microscopy and Spectroscopy, Istituto Italiano di Tecnologia, Genoa, Italy
- University of Turku, Department of Cell Biology and Anatomy, Institute of Biomedicine and Medicity Research Laboratories, Laboratory of Biophysics, Turku, Finland
| | - Marcel Ameloot
- Hasselt University, Biomedical Research Institute (BIOMED), Diepenbeek, Belgium
| | | | | | - Alberto Diaspro
- Nanoscopy, Istituto Italiano di Tecnologia, Genoa, Italy
- Dipartimento di Fisica, University of Genoa, Genoa, Italy
| | - Alberto Tosi
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | - Giuseppe Vicidomini
- Molecular Microscopy and Spectroscopy, Istituto Italiano di Tecnologia, Genoa, Italy
| |
Collapse
|
6
|
Koho SV, Slenders E, Tortarolo G, Castello M, Buttafava M, Villa F, Tcarenkova E, Ameloot M, Bianchini P, Sheppard CJR, Diaspro A, Tosi A, Vicidomini G. Two-photon image-scanning microscopy with SPAD array and blind image reconstruction. BIOMEDICAL OPTICS EXPRESS 2020; 11:2905-2924. [PMID: 32637232 PMCID: PMC7316014 DOI: 10.1364/boe.374398] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Revised: 04/20/2020] [Accepted: 04/26/2020] [Indexed: 05/07/2023]
Abstract
Two-photon excitation (2PE) laser scanning microscopy is the imaging modality of choice when one desires to work with thick biological samples. However, its spatial resolution is poor, below confocal laser scanning microscopy. Here, we propose a straightforward implementation of 2PE image scanning microscopy (2PE-ISM) that, by leveraging our recently introduced single-photon avalanche diode (SPAD) array detector and a novel blind image reconstruction method, is shown to enhance the effective resolution, as well as the overall image quality of 2PE microscopy. With our adaptive pixel reassignment procedure ∼1.6 times resolution increase is maintained deep into thick semi-transparent samples. The integration of Fourier ring correlation based semi-blind deconvolution is shown to further enhance the effective resolution by a factor of ∼2 - and automatic background correction is shown to boost the image quality especially in noisy images. Most importantly, our 2PE-ISM implementation requires no calibration measurements or other input from the user, which is an important aspect in terms of day-to-day usability of the technique.
Collapse
Affiliation(s)
- Sami V. Koho
- Molecular Microscopy and Spectroscopy, Istituto Italiano di Tecnologia, Genoa, Italy
- University of Turku, Department of Cell Biology and Anatomy, Institute of Biomedicine and Medicity Research Laboratories, Laboratory of Biophysics, Turku, Finland
- These authors contributed equally to this work
| | - Eli Slenders
- Molecular Microscopy and Spectroscopy, Istituto Italiano di Tecnologia, Genoa, Italy
- Hasselt University, Biomedical Research Institute (BIOMED), Diepenbeek, Belgium
- These authors contributed equally to this work
| | - Giorgio Tortarolo
- Molecular Microscopy and Spectroscopy, Istituto Italiano di Tecnologia, Genoa, Italy
- Dipartimento di Informatiche, Bioingegneria, Robotica e Ingegneria dei Sistemi, University of Genoa, Italy
| | - Marco Castello
- Molecular Microscopy and Spectroscopy, Istituto Italiano di Tecnologia, Genoa, Italy
| | - Mauro Buttafava
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | - Federica Villa
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | - Elena Tcarenkova
- Molecular Microscopy and Spectroscopy, Istituto Italiano di Tecnologia, Genoa, Italy
- University of Turku, Department of Cell Biology and Anatomy, Institute of Biomedicine and Medicity Research Laboratories, Laboratory of Biophysics, Turku, Finland
| | - Marcel Ameloot
- Hasselt University, Biomedical Research Institute (BIOMED), Diepenbeek, Belgium
| | | | | | - Alberto Diaspro
- Nanoscopy, Istituto Italiano di Tecnologia, Genoa, Italy
- Dipartimento di Fisica, University of Genoa, Genoa, Italy
| | - Alberto Tosi
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | - Giuseppe Vicidomini
- Molecular Microscopy and Spectroscopy, Istituto Italiano di Tecnologia, Genoa, Italy
| |
Collapse
|
7
|
Image scanning microscopy. Curr Opin Chem Biol 2019; 51:74-83. [DOI: 10.1016/j.cbpa.2019.05.011] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Revised: 05/01/2019] [Accepted: 05/13/2019] [Indexed: 12/27/2022]
|
8
|
Sun S, He M, Zhang Z, Wang W, Yang X, Kuang C, Liu X. Enhancing the axial resolution of two-photon imaging. APPLIED OPTICS 2019; 58:4892-4897. [PMID: 31503805 DOI: 10.1364/ao.58.004892] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2019] [Accepted: 05/23/2019] [Indexed: 06/10/2023]
Abstract
An axial-resolution-enhanced two-photon laser scanning microscopy system is presented in this paper. In the proposed method, we use a spatial light modulator (SLM) for the phase modulation of the excitation light. The axially split point spread function (PSF) is generated by loading a 0-π pattern on the SLM. The final quality-enhanced images are acquired by subtracting the two consecutive images acquired by the original PSF and the split PSF. Because of the fluorescence differential processing, the axial elongation of the particles images is suppressed, and the axial resolution is enhanced accordingly. With the axial resolution enhanced, the overlap between layer images is also reduced, which decreases the background noise of the images and enhances the contrast and image quality of the acquired fluorescence images. The capability of axial resolution and contrast enhancement is successfully demonstrated by both theoretical calculation and experimental results.
Collapse
|