Rubinoff I, Kuranov RV, Fang R, Ghassabi Z, Wang Y, Beckmann L, Miller DA, Wollstein G, Ishikawa H, Schuman JS, Zhang HF. Adaptive spectroscopic visible-light optical coherence tomography for clinical retinal oximetry. COMMUNICATIONS MEDICINE 2023; 3:57. [PMID: 37095177 PMCID: PMC10126115 DOI: 10.1038/s43856-023-00288-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Accepted: 04/13/2023] [Indexed: 04/26/2023] Open
Abstract
BACKGROUND Retinal oxygen saturation (sO2) provides essential information about the eye's response to pathological changes that can result in vision loss. Visible-light optical coherence tomography (vis-OCT) is a noninvasive tool that has the potential to measure retinal sO2 in a clinical setting. However, its reliability is currently limited by unwanted signals referred to as spectral contaminants (SCs), and a comprehensive strategy to isolate true oxygen-dependent signals from SCs in vis-OCT is lacking. METHODS We develop an adaptive spectroscopic vis-OCT (ADS-vis-OCT) technique that can adaptively remove SCs and accurately measure sO2 under the unique conditions of each vessel. We also validate the accuracy of ADS-vis-OCT using ex vivo blood phantoms and assess its repeatability in the retina of healthy volunteers. RESULTS In ex vivo blood phantoms, ADS-vis-OCT agrees with a blood gas machine with only a 1% bias in samples with sO2 ranging from 0% to 100%. In the human retina, the root mean squared error between sO2 values in major arteries measured by ADS-vis-OCT and a pulse oximeter is 2.1% across 18 research participants. Additionally, the standard deviations of repeated ADS-vis-OCT measurements of sO2 values in smaller arteries and veins are 2.5% and 2.3%, respectively. Non-adaptive methods do not achieve comparable repeatabilities from healthy volunteers. CONCLUSIONS ADS-vis-OCT effectively removes SCs from human images, yielding accurate and repeatable sO2 measurements in retinal arteries and veins with varying diameters. This work could have important implications for the clinical use of vis-OCT to manage eye diseases.
Collapse
Affiliation(s)
- Ian Rubinoff
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
| | - Roman V Kuranov
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
- Opticent Inc., Evanston, IL, 60201, USA
| | - Raymond Fang
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
| | - Zeinab Ghassabi
- Department of Ophthalmology, New York University, New York, NY, 10017, USA
| | - Yuanbo Wang
- Currently with Department of Ophthalmology, Oregon Health & Science University, Portland, OR, 97239, USA
| | - Lisa Beckmann
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
| | - David A Miller
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
| | - Gadi Wollstein
- Department of Ophthalmology, New York University, New York, NY, 10017, USA
| | - Hiroshi Ishikawa
- Department of Ophthalmology, New York University, New York, NY, 10017, USA
- Currently with Department of Ophthalmology, Oregon Health & Science University, Portland, OR, 97239, USA
| | - Joel S Schuman
- Department of Ophthalmology, New York University, New York, NY, 10017, USA
| | - Hao F Zhang
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA.
| |
Collapse
|
2
|
Fang R, Rubinoff I, Zhang HF. Multiple forward scattering reduces the measured scattering coefficient of whole blood in visible-light optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2022; 13:4510-4527. [PMID: 36187273 PMCID: PMC9484418 DOI: 10.1364/boe.459607] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Revised: 07/18/2022] [Accepted: 07/19/2022] [Indexed: 05/10/2023]
Abstract
The optical properties of blood encode oxygen-dependent information. Noninvasive optical detection of these properties is increasingly desirable to extract biomarkers for tissue health. Recently, visible-light optical coherence tomography (vis-OCT) demonstrated retinal oxygen saturation (sO2) measurements by inversely measuring the oxygen-dependent absorption and scattering coefficients of whole blood. However, vis-OCT may be sensitive to optical scattering properties of whole blood, different from those reported in the literature. Incorrect assumptions of such properties can add additional uncertainties or biases to vis-OCT's sO2 model. This work investigates whole blood's scattering coefficient measured by vis-OCT. Using Monte Carlo simulation of a retinal vessel, we determined that vis-OCT almost exclusively detects multiple-scattered photons in whole blood. Meanwhile, photons mostly forward scatter in whole blood within the visible spectral range, allowing photons to maintain ballistic paths and penetrate deeply, leading to a reduction in the measured scattering coefficient. We defined a scattering scaling factor (SSF) to account for such a reduction and found that SSF varied with measurement conditions, such as numerical aperture, depth resolution, and depth selection. We further experimentally validated SSF in ex vivo blood phantoms with pre-set sO2 levels and in the human retina, both of which agreed well with our simulation.
Collapse
Affiliation(s)
- Raymond Fang
- Department of Biomedical Engineering, Northwestern University, Evanston IL 60208, USA
- These authors contributed equally to this work
| | - Ian Rubinoff
- Department of Biomedical Engineering, Northwestern University, Evanston IL 60208, USA
- These authors contributed equally to this work
| | - Hao F. Zhang
- Department of Biomedical Engineering, Northwestern University, Evanston IL 60208, USA
| |
Collapse
|
3
|
Retinal capillary oximetry with visible light optical coherence tomography. Proc Natl Acad Sci U S A 2020; 117:11658-11666. [PMID: 32398376 DOI: 10.1073/pnas.1918546117] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
Assessing oxygen saturation (sO2) remains challenging but is nonetheless necessary for understanding retinal metabolism. We and others previously achieved oximetry on major retinal vessels and measured the total retinal oxygen metabolic rate in rats using visible-light optical coherence tomography. Here we extend oximetry measurements to capillaries and investigate all three retinal vascular plexuses by amplifying and extracting the spectroscopic signal from each capillary segment under the guidance of optical coherence tomography (OCT) angiography. Using this approach, we measured capillary sO2 in the retinal circulation in rats, demonstrated reproducibility of the results, validated the measurements in superficial capillaries with known perfusion pathways, and determined sO2 responses to hypoxia and hyperoxia in the different retinal capillary beds. OCT capillary oximetry has the potential to provide new insights into the retinal circulation in the normal eye as well as in retinal vascular diseases.
Collapse
|
4
|
Liu R, Cheng S, Tian L, Yi J. Deep spectral learning for label-free optical imaging oximetry with uncertainty quantification. LIGHT, SCIENCE & APPLICATIONS 2019; 8:102. [PMID: 31754429 PMCID: PMC6864044 DOI: 10.1038/s41377-019-0216-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/08/2019] [Revised: 10/17/2019] [Accepted: 11/01/2019] [Indexed: 05/06/2023]
Abstract
Measurement of blood oxygen saturation (sO2) by optical imaging oximetry provides invaluable insight into local tissue functions and metabolism. Despite different embodiments and modalities, all label-free optical-imaging oximetry techniques utilize the same principle of sO2-dependent spectral contrast from haemoglobin. Traditional approaches for quantifying sO2 often rely on analytical models that are fitted by the spectral measurements. These approaches in practice suffer from uncertainties due to biological variability, tissue geometry, light scattering, systemic spectral bias, and variations in the experimental conditions. Here, we propose a new data-driven approach, termed deep spectral learning (DSL), to achieve oximetry that is highly robust to experimental variations and, more importantly, able to provide uncertainty quantification for each sO2 prediction. To demonstrate the robustness and generalizability of DSL, we analyse data from two visible light optical coherence tomography (vis-OCT) setups across two separate in vivo experiments on rat retinas. Predictions made by DSL are highly adaptive to experimental variabilities as well as the depth-dependent backscattering spectra. Two neural-network-based models are tested and compared with the traditional least-squares fitting (LSF) method. The DSL-predicted sO2 shows significantly lower mean-square errors than those of the LSF. For the first time, we have demonstrated en face maps of retinal oximetry along with a pixel-wise confidence assessment. Our DSL overcomes several limitations of traditional approaches and provides a more flexible, robust, and reliable deep learning approach for in vivo non-invasive label-free optical oximetry.
Collapse
Affiliation(s)
- Rongrong Liu
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208 USA
| | - Shiyi Cheng
- Department of Electrical and Computer Engineering, Boston University, Boston, MA 02215 USA
| | - Lei Tian
- Department of Electrical and Computer Engineering, Boston University, Boston, MA 02215 USA
| | - Ji Yi
- Department of Electrical and Computer Engineering, Boston University, Boston, MA 02215 USA
- Department of Biomedical Engineering, Boston University, Boston, MA 02215 USA
- Department of Medicine, Boston University School of Medicine, Boston Medical Center, Boston, MA 02118 USA
| |
Collapse
|
5
|
Pi S, Hormel TT, Wei X, Cepurna W, Camino A, Guo Y, Huang D, Morrison J, Jia Y. Monitoring retinal responses to acute intraocular pressure elevation in rats with visible light optical coherence tomography. NEUROPHOTONICS 2019; 6:041104. [PMID: 31312671 PMCID: PMC6624745 DOI: 10.1117/1.nph.6.4.041104] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2019] [Accepted: 06/21/2019] [Indexed: 05/08/2023]
Abstract
Elevated intraocular pressure (IOP) is an important risk factor for glaucoma. However, the role of IOP in glaucoma progression, as well as retinal physiology in general, remains incompletely understood. We demonstrate the use of visible light optical coherence tomography to measure retinal responses to acute IOP elevation in Brown Norway rats. We monitored retinal responses in reflectivity, angiography, blood flow, oxygen saturation ( sO 2 ), and oxygen metabolism over a range of IOP from 10 to 100 mmHg. As IOP was elevated, nerve fiber layer reflectivity was found to decrease. Vascular perfusion in the three retinal capillary plexuses remained steady until IOP exceeded 70 mmHg and arterial flow was noted to reverse periodically at high IOPs. However, a significant drop in total retinal blood flow was observed first at 40 mmHg. As IOP increased, the venous sO 2 demonstrated a gradual decrease despite steady arterial sO 2 , which is consistent with increased arterial-venous oxygen extraction across the retinal capillary beds. Calculated total retinal oxygen metabolism was steady, reflecting balanced responses of blood flow and oxygen extraction, until IOP exceeded 40 mmHg, and fell to 0 at 70 and 80 mmHg. Above this, measurements were unattainable. All measurements reverted to baseline when the IOP was returned to 10 mmHg, indicating good recovery following acute pressure challenge. These results demonstrate the ability of this system to monitor retinal oxygen metabolism noninvasively and how it can help us understand retinal responses to elevated IOP.
Collapse
Affiliation(s)
- Shaohua Pi
- Oregon Health and Science University, Casey Eye Institute, Portland, Oregon, United States
| | - Tristan T. Hormel
- Oregon Health and Science University, Casey Eye Institute, Portland, Oregon, United States
| | - Xiang Wei
- Oregon Health and Science University, Casey Eye Institute, Portland, Oregon, United States
| | - William Cepurna
- Oregon Health and Science University, Casey Eye Institute, Portland, Oregon, United States
| | - Acner Camino
- Oregon Health and Science University, Casey Eye Institute, Portland, Oregon, United States
| | - Yukun Guo
- Oregon Health and Science University, Casey Eye Institute, Portland, Oregon, United States
| | - David Huang
- Oregon Health and Science University, Casey Eye Institute, Portland, Oregon, United States
| | - John Morrison
- Oregon Health and Science University, Casey Eye Institute, Portland, Oregon, United States
| | - Yali Jia
- Oregon Health and Science University, Casey Eye Institute, Portland, Oregon, United States
- Address all correspondence to Yali Jia, E-mail:
| |
Collapse
|