1
|
Zhang Y, Liu G, Li X, Gong H, Luo Q, Yang X. On-line clearing and staining method for the efficient optical imaging of large volume samples at the cellular resolution. BIOMEDICAL OPTICS EXPRESS 2023; 14:4800-4813. [PMID: 37791250 PMCID: PMC10545182 DOI: 10.1364/boe.499115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 08/13/2023] [Accepted: 08/14/2023] [Indexed: 10/05/2023]
Abstract
Optical microscopy is a powerful tool for exploring the structure and function of organisms. However, the three-dimensional (3D) imaging of large volume samples is time-consuming and difficult. In this manuscript, we described an on-line clearing and staining method for efficient imaging of large volume samples at the cellular resolution. The optimized cocktail can increase staining and imaging depth to reduce the sectioning and scanning time, more than doubling the operational efficiency of the system. Using this method, we demonstrated the rapid acquisition of Aβ plaques in whole mouse brain and obtained a complete set of cytoarchitecture images of an adult porcine hemisphere at 1.625 × 1.625 × 10 µm3 voxel resolution for about 49 hours.
Collapse
Affiliation(s)
- Yunfei Zhang
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, MoE Key Laboratory for Biomedical Photonics, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Guangcai Liu
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, MoE Key Laboratory for Biomedical Photonics, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Xiangning Li
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, MoE Key Laboratory for Biomedical Photonics, Huazhong University of Science and Technology, Wuhan 430074, China
- HUST-Suzhou Institute for Brainsmatics, JITRI, Suzhou, 215123, China
- Key Laboratory of Biomedical Engineering of Hainan Province, School of Biomedical Engineering, Hainan University, Haikou, China
| | - Hui Gong
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, MoE Key Laboratory for Biomedical Photonics, Huazhong University of Science and Technology, Wuhan 430074, China
- HUST-Suzhou Institute for Brainsmatics, JITRI, Suzhou, 215123, China
| | - Qingming Luo
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, MoE Key Laboratory for Biomedical Photonics, Huazhong University of Science and Technology, Wuhan 430074, China
- HUST-Suzhou Institute for Brainsmatics, JITRI, Suzhou, 215123, China
- Key Laboratory of Biomedical Engineering of Hainan Province, School of Biomedical Engineering, Hainan University, Haikou, China
| | - Xiaoquan Yang
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, MoE Key Laboratory for Biomedical Photonics, Huazhong University of Science and Technology, Wuhan 430074, China
- HUST-Suzhou Institute for Brainsmatics, JITRI, Suzhou, 215123, China
| |
Collapse
|
2
|
Wang Z, Xie R, Shi Q, Li Y, Chang J, Yuan J, Gong H, Chen J. Vacuum-assisted tissue embedding for whole-heart imaging. BIOMEDICAL OPTICS EXPRESS 2023; 14:2539-2550. [PMID: 37342702 PMCID: PMC10278630 DOI: 10.1364/boe.488766] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 04/25/2023] [Accepted: 04/26/2023] [Indexed: 06/23/2023]
Abstract
The use of combined optical imaging and tissue sectioning has potential for use in visualizing heart-wide fine structures at single-cell resolution. However, existing tissue preparation methods fail to generate ultrathin cavity-containing cardiac tissue slices with minimal deformation. This study developed an efficient vacuum-assisted tissue embedding method to prepare high-filled, agarose-embedded whole-heart tissue. Utilizing optimized vacuum parameters, we achieved 94% filled whole-heart tissue with the thinnest cut slice of 5 µm. We subsequently imaged a whole mouse heart sample using vibratome-integrated fluorescence micro-optical sectioning tomography (fMOST) with a voxel size of 0.32 µm × 0.32 µm × 1 µm. The imaging results indicated that the vacuum-assisted embedding method enabled whole-heart tissue to withstand long-term thin cutting while ensuring that slices were consistent and of high quality.
Collapse
Affiliation(s)
- Zhi Wang
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, MoE Key Laboratory for Biomedical Photonics, Huazhong University of Science and Technology, Wuhan, China
- HUST-Suzhou Institute for Brainsmatics, JITRI, Suzhou, China
| | - Ruiheng Xie
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, MoE Key Laboratory for Biomedical Photonics, Huazhong University of Science and Technology, Wuhan, China
| | - Qishuo Shi
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, MoE Key Laboratory for Biomedical Photonics, Huazhong University of Science and Technology, Wuhan, China
| | - Yafeng Li
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, MoE Key Laboratory for Biomedical Photonics, Huazhong University of Science and Technology, Wuhan, China
| | - Jin Chang
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, MoE Key Laboratory for Biomedical Photonics, Huazhong University of Science and Technology, Wuhan, China
| | - Jing Yuan
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, MoE Key Laboratory for Biomedical Photonics, Huazhong University of Science and Technology, Wuhan, China
- HUST-Suzhou Institute for Brainsmatics, JITRI, Suzhou, China
| | - Hui Gong
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, MoE Key Laboratory for Biomedical Photonics, Huazhong University of Science and Technology, Wuhan, China
- HUST-Suzhou Institute for Brainsmatics, JITRI, Suzhou, China
| | - Jianwei Chen
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, MoE Key Laboratory for Biomedical Photonics, Huazhong University of Science and Technology, Wuhan, China
- HUST-Suzhou Institute for Brainsmatics, JITRI, Suzhou, China
| |
Collapse
|
3
|
Li Y, Ding Z, Deng L, Fan G, Zhang Q, Gong H, Li A, Yuan J, Chen J. Precision vibratome for high-speed ultrathin biotissue cutting and organ-wide imaging. iScience 2021; 24:103016. [PMID: 34522859 PMCID: PMC8426277 DOI: 10.1016/j.isci.2021.103016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Revised: 06/25/2021] [Accepted: 08/18/2021] [Indexed: 10/31/2022] Open
Abstract
Cutting tissues into ultrathin slices is highly desired in sectioning-based organ-wide imaging. However, it is difficult to perform tissue cutting at a high speed with excellent quality. Here, we design a precision vibratome based on a paired double parallelogram flexure, which enables a vibrating blade to move strictly along a straight line. Meanwhile, we develop a high-speed cutting method that does not compromise cutting quality, which the vibratome operated at a high frequency mode. The characterized parasitic motion errors of a 180-Hz vibratome were less than 300 nm. It achieved a cutting speed six times that of an 85-Hz vibratome with acceptable quality. The capacity of the vibratome was investigated by organ-wide imaging, and the results revealed that it can be adapted in different tissues, such as the mouse brain and liver. This new vibratome shows great potential in speeding up organ-wide imaging applications especially for large volume biotissues.
Collapse
Affiliation(s)
- Yafeng Li
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China.,MoE Key Laboratory for Biomedical Photonics, School of Engineering Sciences, Huazhong University of Science and Technology, Wuhan, Hubei 430074, China.,Innovation Institute, Huazhong University of Science and Technology, Wuhan, Hubei 430074, China
| | - Zhangheng Ding
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China.,MoE Key Laboratory for Biomedical Photonics, School of Engineering Sciences, Huazhong University of Science and Technology, Wuhan, Hubei 430074, China
| | - Lei Deng
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China.,MoE Key Laboratory for Biomedical Photonics, School of Engineering Sciences, Huazhong University of Science and Technology, Wuhan, Hubei 430074, China
| | - Guoqing Fan
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China.,MoE Key Laboratory for Biomedical Photonics, School of Engineering Sciences, Huazhong University of Science and Technology, Wuhan, Hubei 430074, China
| | - Qi Zhang
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China.,MoE Key Laboratory for Biomedical Photonics, School of Engineering Sciences, Huazhong University of Science and Technology, Wuhan, Hubei 430074, China
| | - Hui Gong
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China.,MoE Key Laboratory for Biomedical Photonics, School of Engineering Sciences, Huazhong University of Science and Technology, Wuhan, Hubei 430074, China.,HUST-Suzhou Institute for Brainsmatics, Suzhou 215125, China
| | - Anan Li
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China.,MoE Key Laboratory for Biomedical Photonics, School of Engineering Sciences, Huazhong University of Science and Technology, Wuhan, Hubei 430074, China.,HUST-Suzhou Institute for Brainsmatics, Suzhou 215125, China
| | - Jing Yuan
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China.,MoE Key Laboratory for Biomedical Photonics, School of Engineering Sciences, Huazhong University of Science and Technology, Wuhan, Hubei 430074, China.,HUST-Suzhou Institute for Brainsmatics, Suzhou 215125, China
| | - Jianwei Chen
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China.,MoE Key Laboratory for Biomedical Photonics, School of Engineering Sciences, Huazhong University of Science and Technology, Wuhan, Hubei 430074, China.,HUST-Suzhou Institute for Brainsmatics, Suzhou 215125, China
| |
Collapse
|
4
|
Abstract
When neuroscience’s focus moves from molecular and cellular level to systems level, information technology mixes in and cultivates a new branch neuroinformatics. Especially under the investments of brain initiatives all around the world, brain atlases and connectomics are identified as the substructure to understand the brain. We think it is time to call for a potential interdisciplinary subject, brainsmatics, referring to brain-wide spatial informatics science and emphasizing on precise positioning information affiliated to brain-wide connectome, genome, proteome, transcriptome, metabolome, etc. Brainsmatics methodology includes tracing, surveying, visualizing, and analyzing brain-wide spatial information. Among all imaging techniques, optical imaging is the most appropriate solution to achieve whole-brain connectome in consistent single-neuron resolution. This review aims to introduce contributions of optical imaging to brainsmatics studies, especially the major strategies applied in tracing and surveying processes. After discussions on the state-of-the-art technology, the development objectives of optical imaging in brainsmatics field are suggested. We call for a global contribution to the brainsmatics field from all related communities such as neuroscientists, biologists, engineers, programmers, chemists, mathematicians, physicists, clinicians, pharmacists, etc. As the leading approach, optical imaging will, in turn, benefit from the prosperous development of brainsmatics.
Collapse
|